1
|
Majdoub F, Belin M, Perret-Liaudet J. Ultra-low friction in soft contact lenses: Analysis of dynamic free responses measured by the dynamic oscillating tribometer. J Mech Behav Biomed Mater 2024; 149:106236. [PMID: 37984287 DOI: 10.1016/j.jmbbm.2023.106236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/06/2023] [Accepted: 11/08/2023] [Indexed: 11/22/2023]
Abstract
Friction coefficient is considered as a measurement for clinical comfort of soft contact lenses. One of the main challenges in the tribology field is to evaluate the friction in soft materials such as soft contact lenses. In this work, we aim to evaluate the friction at the eyelid-lens contact using a new technique. This technique is based on a single-degree-of-freedom (SDOF) mass-spring system having a sliding contact. The experimental technique measures the free responses of the mechanical system. The friction is then evaluated from the damped free responses with a high accuracy. A variety of soft contact lenses are tested with some lubricants under many physiological conditions. The results are discussed and compared with those in the literature.
Collapse
Affiliation(s)
- Fida Majdoub
- LabECAM, ECAM La Salle, Université de Lyon, 69005, Lyon, France.
| | - Michel Belin
- Laboratory of Tribology and System Dynamics, École Centrale de Lyon, UMR CNRS 5513, Université de Lyon, 69134, Écully, France
| | - Joël Perret-Liaudet
- Laboratory of Tribology and System Dynamics, École Centrale de Lyon, UMR CNRS 5513, Université de Lyon, 69134, Écully, France
| |
Collapse
|
2
|
Costa D, De Matteis V, Treso F, Montani G, Martino M, Rinaldi R, Corrado M, Cascione M. Impact of the physical properties of contact lens materials on the discomfort: role of the coefficient of friction. Colloids Surf B Biointerfaces 2024; 233:113630. [PMID: 37956592 DOI: 10.1016/j.colsurfb.2023.113630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 11/15/2023]
Abstract
Contact Lens Discomfort (CLD) is the main cause in contact lens (CLs) discontinuation, referred in literature as drop-out phenomenon. Despite such evidence was reported in several clinical studies, a relationship between physico-chemical properties of CLs and CLD is not still totally understood. In this regard, the friction of CLs surfaces seems to be related to discomfort feeling events, probably due to an alteration of the lubricate function of the tear film after the CL placement inside the ocular environment. In the last years, many studies have been finalized to the friction measurements of CLs surface, finding conflicting data due to a lack in standardized protocol. The aim of this review is primarily to show evident relationships between CLs surface properties (i.e. wettability, tear evaporation, tear film quality, etc.) and the coefficient of friction (CoF), resulting therefore the most relevant physical quantity in the CLs characterization. In addition, we reported the most recent studies in CLs tribology, which highlight that the introduction of a standard protocol in CoF measurements is necessary to obtain reproducible results, considering the aim to evaluate in a more precise way the relationship between this material surface property and comfort in CLs users.
Collapse
Affiliation(s)
- D Costa
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - V De Matteis
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy.
| | - F Treso
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - G Montani
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - M Martino
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - R Rinaldi
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy
| | - M Corrado
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - M Cascione
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy.
| |
Collapse
|
3
|
Ouyang T, Su S, Deng H, Liu Y, Cui L, Rong J, Zhao J. Superhydrophilic Poly(2-hydroxyethyl methacrylate) Hydrogel with Nanosilica Covalent Coating: A Promising Contact Lens Material for Resisting Tear Protein Deposition and Bacterial Adhesion. ACS Biomater Sci Eng 2023; 9:5653-5665. [PMID: 37736672 DOI: 10.1021/acsbiomaterials.3c00856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
Tear protein deposition and bacterial adhesion are the main drawbacks of the hydrogel contact lens. In this study, we developed a novel superhydrophilic poly(2-hydroxyethyl methacrylate) (NSCC-pHEMA) hydrogel with nanosilica covalent coating by the combination of colloidal silica immersion and dehydration treatment. The infrared spectroscopy and energy dispersive X-ray spectroscopy analyses confirmed the successful formation of Si-O covalent bonding between nanosilica and pHEMA hydrogel. This coating was highly stable against powerful sonication or long-term shaking immersion treatment. Among various NSCC-pHEMA hydrogels with different colloidal silica concentrations, the 7%NSCC-pHEMA hydrogel generated a superhydrophilic micro wrinkle surface with a root-mean-square roughness of 43.10 nm, which dramatically reduced the deposition of lysozyme and bovine serum albumin by 65% and 57%, respectively, and decreased the adhesion of S. aureus and E. coli by 59% and 66%, respectively, in comparison to the pHEMA hydrogel. However, the nanosilica coating had little effect on the mechanical properties, light transmittance, oxygen permeability, and equilibrium water content of the pHEMA hydrogel. NSCC-pHEMA hydrogels were nontoxic to both mouse fibroblasts (L929) and human immortalized keratinocytes (HaCaT). Thus, the superhydrophilic NSCC-pHEMA hydrogel is a potential contact lens material for resisting tear protein deposition and bacterial adhesion.
Collapse
Affiliation(s)
- Tao Ouyang
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Shuxian Su
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Haotian Deng
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Yuying Liu
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Lishu Cui
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
| | - Jianhua Rong
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
- Engineering Research Center of Artificial Organs and Materials, Ministry of Education, Guangzhou 511436, China
| | - Jianhao Zhao
- Department of Materials Science and Engineering, College of Chemistry and Materials Science, Jinan University, Guangzhou 511436, China
- Engineering Research Center of Artificial Organs and Materials, Ministry of Education, Guangzhou 511436, China
| |
Collapse
|
4
|
Iwashita H, Mabuchi K, Itokawa T, Okajima Y, Suzuki T, Hori Y. Evaluation of the Lubricating Effect of Hyaluronic Acid on Contact Lenses Using a Pendulum-Type Friction Tester Under Mimicking Physiological Conditions. Eye Contact Lens 2022; 48:83-87. [PMID: 35058419 PMCID: PMC8759543 DOI: 10.1097/icl.0000000000000853] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/12/2021] [Indexed: 12/02/2022]
Abstract
OBJECTIVE To evaluate the lubricating effect of hyaluronic acid (HA) on soft contact lenses (SCLs) measured using a pendulum-type friction tester. METHODS We measured the coefficient of friction (CoF) of narafilcon A, delefilcon A, and etafilcon A with polyvinylpyrrolidone (PVP), daily disposable SCL material, using a modified pendulum-type friction tester. Sample SCLs were set on an acrylic plastic half-ball and placed into the polyethylene terephthalate hemisphere cup filled with 0.4 mL of test lubricants that included saline and 0.05%, 0.1%, 0.2%, 0.3%, 0.4%, and 0.5% (wt/vol) HA (molecular weight, 850 kDa). The viscosities of saline and HA were measured using an Ubbelohde viscometer. RESULTS The CoF of the SCL under a low concentration (0.05%) of HA was the lowest and significantly lower than saline in narafilcon A and delefilcon A (P<0.05, Steel multiple comparison test). Under higher HA concentrations (0.3%, 0.4%, and 0.5%), the CoF was significantly higher than that of saline (P<0.01, Steel' multiple comparison test) in all three SCLs. There were no significant differences of CoF among three SCLs in saline and all concentrations of HA. The HA viscosities increased exponentially with the concentration (Y=1.2829e9.286X). CONCLUSION The viscosity of a high concentration of HA may increase the friction of SCLs, which may have a deleterious effect on the ocular surface.
Collapse
Affiliation(s)
- Hiroko Iwashita
- Department of Ophthalmology (H.I., K.M., T.I., Y.O., T.S., Y.H.), Faculty of Medicine, Toho University, Tokyo, Japan; and Department of Biomedical Engineering (K.M.), School of Allied Health Sciences, Kitasato University, Kanagawa, Japan
| | - Kiyoshi Mabuchi
- Department of Ophthalmology (H.I., K.M., T.I., Y.O., T.S., Y.H.), Faculty of Medicine, Toho University, Tokyo, Japan; and Department of Biomedical Engineering (K.M.), School of Allied Health Sciences, Kitasato University, Kanagawa, Japan
| | - Takashi Itokawa
- Department of Ophthalmology (H.I., K.M., T.I., Y.O., T.S., Y.H.), Faculty of Medicine, Toho University, Tokyo, Japan; and Department of Biomedical Engineering (K.M.), School of Allied Health Sciences, Kitasato University, Kanagawa, Japan
| | - Yukinobu Okajima
- Department of Ophthalmology (H.I., K.M., T.I., Y.O., T.S., Y.H.), Faculty of Medicine, Toho University, Tokyo, Japan; and Department of Biomedical Engineering (K.M.), School of Allied Health Sciences, Kitasato University, Kanagawa, Japan
| | - Takashi Suzuki
- Department of Ophthalmology (H.I., K.M., T.I., Y.O., T.S., Y.H.), Faculty of Medicine, Toho University, Tokyo, Japan; and Department of Biomedical Engineering (K.M.), School of Allied Health Sciences, Kitasato University, Kanagawa, Japan
| | - Yuichi Hori
- Department of Ophthalmology (H.I., K.M., T.I., Y.O., T.S., Y.H.), Faculty of Medicine, Toho University, Tokyo, Japan; and Department of Biomedical Engineering (K.M.), School of Allied Health Sciences, Kitasato University, Kanagawa, Japan
| |
Collapse
|
5
|
Nguyen DCT, Dowling J, Ryan R, McLoughlin P, Fitzhenry L. Pharmaceutical-loaded contact lenses as an ocular drug delivery system: A review of critical lens characterization methodologies with reference to ISO standards. Cont Lens Anterior Eye 2021; 44:101487. [PMID: 34353748 DOI: 10.1016/j.clae.2021.101487] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 06/28/2021] [Accepted: 07/04/2021] [Indexed: 01/12/2023]
Abstract
Therapeutic contact lenses for ocular drug delivery have received considerable interest as they can potentially enhance ocular bioavailability, increase patient compliance, and reduce side effects. Along with the successful in vitro and in vivo studies on sustained drug delivery through contact lenses, lens critical properties such as water content, optical transparency and modulus have also been investigated. Aside from issues such as drug stability or burst release, the potential for the commercialization of pharmaceutical-loaded lenses can be limited by the alteration of lens physical and chemical properties upon the incorporation of therapeutic or non-therapeutic components. This review outlines advances in the use of pharmaceutical-loaded contact lenses and their relevant characterization methodologies as a potential ocular drug delivery system from 2010 to 2020, while summarizing current gaps and challenges in this field. A key reference point for this review is the relevant ISO standards on contact lenses, relating to the associated characterization methodologies. The content of this review is categorized based on the chemical, physical and mechanical properties of the loaded lens with the shortcomings of such analytical technologies examined.
Collapse
Affiliation(s)
- Dan Chau Thuy Nguyen
- Ocular Therapeutics Research Group (OTRG), Pharmaceutical & Molecular Biotechnology Research Centre (PMBRC), Waterford Institute of Technology, Waterford City, County Waterford X91 K0EK, Ireland.
| | - Joseph Dowling
- Research and Development Department, Bausch + Lomb Ireland Ltd., Waterford City, County Waterford X91 V383, Ireland
| | - Richie Ryan
- Ocular Therapeutics Research Group (OTRG), Pharmaceutical & Molecular Biotechnology Research Centre (PMBRC), Waterford Institute of Technology, Waterford City, County Waterford X91 K0EK, Ireland
| | - Peter McLoughlin
- Ocular Therapeutics Research Group (OTRG), Pharmaceutical & Molecular Biotechnology Research Centre (PMBRC), Waterford Institute of Technology, Waterford City, County Waterford X91 K0EK, Ireland
| | - Laurence Fitzhenry
- Ocular Therapeutics Research Group (OTRG), Pharmaceutical & Molecular Biotechnology Research Centre (PMBRC), Waterford Institute of Technology, Waterford City, County Waterford X91 K0EK, Ireland
| |
Collapse
|
6
|
Mabuchi K, Iwashita H, Sakai R, Ujihira M, Hori Y. Development of a pendulum machine for measuring contact lens friction. BIOSURFACE AND BIOTRIBOLOGY 2021. [DOI: 10.1049/bsb2.12004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Kiyoshi Mabuchi
- Department of Biomedical Engineering Kitasato University 1‐15‐1, Kitasato Sagamihara Japan
- Graduate School of Medicine Toho University 5‐21‐16, Omorinishi Ota‐ku, Tokyo Japan
| | - Hiroko Iwashita
- Graduate School of Medicine Toho University 5‐21‐16, Omorinishi Ota‐ku, Tokyo Japan
| | - Rina Sakai
- Department of Biomedical Engineering Kitasato University 1‐15‐1, Kitasato Sagamihara Japan
| | - Masanobu Ujihira
- Department of Biomedical Engineering Kitasato University 1‐15‐1, Kitasato Sagamihara Japan
| | - Yuichi Hori
- Graduate School of Medicine Toho University 5‐21‐16, Omorinishi Ota‐ku, Tokyo Japan
| |
Collapse
|
7
|
Eftimov PB, Yokoi N, Peev N, Paunski Y, Georgiev GA. Relationships between the material properties of silicone hydrogels: Desiccation, wettability and lubricity. J Biomater Appl 2020; 35:933-946. [PMID: 33135571 PMCID: PMC7917563 DOI: 10.1177/0885328220967526] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Silicone hydrogels (SiHy), represent composite matrices composed of hydrophobic gas permeable silicone (Si) rich core and a surface enriched with hydrophilic polymer moieties. Their utilization in contact lens design requires number of SiHy properties (hydration, wettability, lubricity) to be optimized for the challenging conditions at the ocular surface. Typical limitations in literature are that (i) these properties are studied in isolation, monitoring only one parameter but not the rest of them, and (ii) measurements are performed with hydrated samples immediately after removal from storage solutions. Here we study the simultaneous evolution of critical material properties (evaporative loss of water, water contact angle, coefficient of friction) of different SiHy subjected to continuous blink-like desiccation/rehydration cycling. SiHy with wetting agents incorporated in their core (narafilcon A, senofilcon A) were particularly susceptible to extended desiccation. Stenfilcon A, a material with only 3% bulk Si content maintained its performance for 4 h of cycling, and delefilcon A (80% surface water content) resisted extended 8 h of desiccation/rehydration runs. Strong correlation exists between the evolution of SiHy wettability and lubricity at ≥4 h of blink-like cycling. Understanding the interplay between SiHy properties bears insights for knowledge based design of novel ophthalmic materials.
Collapse
Affiliation(s)
| | - Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Nikola Peev
- Faculty of Physics, Sofia University "St. Kliment Ohridski", Bulgaria
| | - Yasen Paunski
- Institute of Robotics, Bulgarian Academy of Sciences, Sofia, Bulgaria
| | | |
Collapse
|
8
|
Yu Y, Guerriero T, Carpenter J, Chauhan A. Transport of polymers in contact lenses and impact on lubricity. Colloids Surf A Physicochem Eng Asp 2020. [DOI: 10.1016/j.colsurfa.2020.125123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
9
|
Qin D, Zhu L, Zhou T, Liao Z, Liang M, Qin L, Cai Z. Tribological behaviour of two kinds of typical hydrogel contact lenses in different lubricants. BIOSURFACE AND BIOTRIBOLOGY 2019. [DOI: 10.1049/bsbt.2019.0029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Dong Qin
- Ophthalmology DepartmentChengdu Third People's HospitalChengdu610031People's Republic of China
| | - Li‐Ting Zhu
- Tribology Research InstituteKey Laboratory of Advanced Technologies of MaterialsMinistry of EducationSouthwest Jiaotong UniversityChengdu610031People's Republic of China
| | - Teng Zhou
- Tribology Research InstituteKey Laboratory of Advanced Technologies of MaterialsMinistry of EducationSouthwest Jiaotong UniversityChengdu610031People's Republic of China
| | - Zhi‐Qiang Liao
- Ophthalmology DepartmentChengdu Third People's HospitalChengdu610031People's Republic of China
| | - Ming Liang
- Ophthalmology DepartmentChengdu Third People's HospitalChengdu610031People's Republic of China
| | - Ling Qin
- Ophthalmology DepartmentChengdu Third People's HospitalChengdu610031People's Republic of China
| | - Zhen‐Bing Cai
- Tribology Research InstituteKey Laboratory of Advanced Technologies of MaterialsMinistry of EducationSouthwest Jiaotong UniversityChengdu610031People's Republic of China
| |
Collapse
|
10
|
Abstract
OBJECTIVES Cosmetic contact lenses are increasingly popular because of their eye enhancing cosmetic benefits. The pigment particles used in these lenses can impact lens surface characteristics. This article examines the surface characteristics and the differences between the clear and the pigmented regions among five limbal ring design lenses. METHODS Scanning electron microscopy was used to determine the location and depth of the pigment particles from the lens surface. The coefficient of friction (CoF) was determined with a Basalt-MUST microtribometer at clear and pigmented regions on either the front or the back surface. Atomic force microscopy was used to determine the surface roughness of each lens in root-mean-square (RMS) units at clear and pigmented regions. A linear mixed model for repeated measures was used for the analysis of the CoF and RMS roughness to compare all lenses. RESULTS Four lens types had pigments exposed on the surface and one lens type had pigment fully enclosed. The CoF difference between clear and pigmented regions were similar and not statistically significant (P=0.0124) for the lens type with pigments enclosed, whereas the CoF difference for the other four lens types showed statistically significant difference (P<0.0001). CONCLUSIONS Of the lenses tested here, cosmetic contact lenses with pigments enclosed in the lens matrix provided a more consistent surface between clear and pigmented regions compared with lenses that had exposed pigments.
Collapse
|
11
|
Lertola AC, Wang B, Li L. Understanding the Friction of Nanometer-Thick Fluorinated Ionic Liquids. Ind Eng Chem Res 2018. [DOI: 10.1021/acs.iecr.8b03044] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Anne C. Lertola
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| | - Bingchen Wang
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| | - Lei Li
- Department of Chemical and Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| |
Collapse
|
12
|
Gong X, West B, Taylor A, Li L. Study on Nanometer-Thick Room-Temperature Ionic Liquids (RTILs) for Application as the Media Lubricant in Heat-Assisted Magnetic Recording (HAMR). Ind Eng Chem Res 2016. [DOI: 10.1021/acs.iecr.6b00822] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Xiao Gong
- Department of Chemical & Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- State
Key Laboratory of Silicate Materials for Architectures, Wuhan University of Technology, Wuhan 430070, China
| | - Benjamin West
- Department of Chemical & Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| | - Alex Taylor
- Department of Chemical & Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| | - Lei Li
- Department of Chemical & Petroleum Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| |
Collapse
|
13
|
In-vitro method for determining corneal tissue friction and damage due to contact lens sliding. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.biotri.2016.01.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
14
|
Silva D, Fernandes A, Nunes T, Colaço R, Serro A. The effect of albumin and cholesterol on the biotribological behavior of hydrogels for contact lenses. Acta Biomater 2015; 26:184-94. [PMID: 26278500 DOI: 10.1016/j.actbio.2015.08.011] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Revised: 07/16/2015] [Accepted: 08/12/2015] [Indexed: 10/23/2022]
Abstract
The irritation/discomfort associated with the use of contact lenses (CLs) is often related to the eyelid-lens friction. Although the use of such devices is widespread, the information about the influence of the lacrimal fluid biomolecules on the tribological behavior of the CLs hydrogels is scarce. In this work, we investigated the effect of the presence of albumin and cholesterol in the lubricant medium, on the frictional response of two model hydrogels for CLs: a hydroxyethylmethacrylate based hydrogel, HEMA/PVP, and a silicone based one, TRIS/NVP/HEMA. Tribological experiments were done in a nanotribometer, in water and in the presence of solutions of those biomolecules. It was observed a significant increase of the friction coefficient (μ) for HEMA/PVP when the lubricant contains cholesterol, and for TRIS/NVP/HEMA when it contains albumin. Solid-state NMR and DSC analysis revealed that HEMA/PVP hydrated in cholesterol solution has a lower amount of free and loosely bound water than the hydrogel hydrated in water. Therefore, a smaller amount of water shall be released into the contact region during the friction tests with cholesterol solution, leading to a thinner film in the contact zone, and consequently to a higher μ. Concerning TRIS/NVP/HEMA, QCM-D studies showed that this hydrogel adsorbs less albumin than HEMA/PVP and that the formed film is more rigid, which can explain the increase of μ. The obtained results contribute to understand the influence of lacrimal fluid composition on the tribological behavior of CLs materials, being relevant for the selection and optimization of these devices. STATEMENT OF SIGNIFICANCE Understanding the tribological behavior of contact lenses (CLs) materials in contact with the lacrimal fluid and the role of its components is of major importance to optimize the comfort and overall success of these devices. Nevertheless, the available information on this subject in the literature is scarce. In this work, the effect of albumin and cholesterol (two of the main components of the lacrimal fluid) on the frictional response of distinct types of hydrogels suitable for CLs, is compared, for the first time. Significant differences were observed with the two molecules, depending on the material, stressing the need to further study this issue to understand, predict and optimize the in vivo performance of CLs.
Collapse
|
15
|
|
16
|
Torrent-Burgués J, Sanz F. AFM in mode Peak Force applied to the study of un-worn contact lenses. Colloids Surf B Biointerfaces 2014; 121:388-94. [DOI: 10.1016/j.colsurfb.2014.06.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2014] [Revised: 05/26/2014] [Accepted: 06/09/2014] [Indexed: 10/25/2022]
|
17
|
Kozbial A, Li L. Study on the friction of κ-carrageenan hydrogels in air and aqueous environments. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 36:173-9. [DOI: 10.1016/j.msec.2013.12.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2013] [Revised: 09/11/2013] [Accepted: 12/06/2013] [Indexed: 12/21/2022]
|
18
|
|