1
|
Sardaru MC, Rosca I, Morariu S, Ursu EL, Rotaru A. Synergistic Antibacterial Action of Norfloxacin-Encapsulated G4 Hydrogels: The Role of Boronic Acid and Cyclodextrin. Gels 2025; 11:35. [PMID: 39852006 PMCID: PMC11764500 DOI: 10.3390/gels11010035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2024] [Revised: 12/28/2024] [Accepted: 12/29/2024] [Indexed: 01/26/2025] Open
Abstract
In this present study, we developed and characterized a series of supramolecular G4 hydrogels by integrating β-cyclodextrin (β-CD) and boronic acid linkers into a supramolecular matrix to enhance antibacterial activity against Staphylococcus aureus (S. aureus). We systematically investigated how varying the number of free boronic acid moieties (ranging from two to six), along with guanosine and β-CD content, influences both the structural integrity and antimicrobial efficacy of these materials. Comprehensive characterization using FTIR, circular dichroism, X-ray diffraction, SEM, AFM, and rheological measurements confirmed successful synthesis and revealed that higher boronic acid content correlated with a stronger, more organized network. The most effective hydrogel displayed an inhibition zone of 25 mm in disk diffusion assays, and was further explored as a drug delivery platform, with the aim to exploit the capacity of the free β-CD cavity of the hydrogels to incorporate hydrophobic drugs. Norfloxacin (Nfx), a poorly water-soluble antibiotic, was successfully encapsulated within the hydrogel matrix through the inclusion of complex formation with β-CD, improving its solubility and enabling sustained, targeted release. The Nfx-loaded hydrogel expanded the inhibition zone to 49 mm and completely eradicated S. aureus cells within 24 h, outperforming both the unloaded hydrogel and free Nfx. These results highlight the synergistic effect of boronic acid moieties and controlled drug release, underlining the potential of these hydrogels as versatile platforms for localized antimicrobial therapy, such as in wound dressings or implant coatings. Nevertheless, further in vivo studies and long-term stability assessments are needed to fully establish clinical relevance, safety, and scalability before these systems can be translated into routine healthcare applications.
Collapse
Affiliation(s)
- Monica-Cornelia Sardaru
- The Research Institute of the University of Bucharest (ICUB), 90 Sos. Panduri, 050663 Bucharest, Romania;
- “Petru Poni” Institute of Macromolecular Chemistry, Romanian Academy, Centre of Advanced Research in Bionanoconjugates and Biopolymers, Grigore Ghica Voda Alley 41 A, 700487 Iasi, Romania; (I.R.); (E.-L.U.)
| | - Irina Rosca
- “Petru Poni” Institute of Macromolecular Chemistry, Romanian Academy, Centre of Advanced Research in Bionanoconjugates and Biopolymers, Grigore Ghica Voda Alley 41 A, 700487 Iasi, Romania; (I.R.); (E.-L.U.)
| | - Simona Morariu
- “Petru Poni” Institute of Macromolecular Chemistry, Romanian Academy, Natural Polymers, Bioactive and Biocompatible Materials, Grigore Ghica Voda Alley 41 A, 700487 Iasi, Romania;
| | - Elena-Laura Ursu
- “Petru Poni” Institute of Macromolecular Chemistry, Romanian Academy, Centre of Advanced Research in Bionanoconjugates and Biopolymers, Grigore Ghica Voda Alley 41 A, 700487 Iasi, Romania; (I.R.); (E.-L.U.)
| | - Alexandru Rotaru
- “Petru Poni” Institute of Macromolecular Chemistry, Romanian Academy, Centre of Advanced Research in Bionanoconjugates and Biopolymers, Grigore Ghica Voda Alley 41 A, 700487 Iasi, Romania; (I.R.); (E.-L.U.)
| |
Collapse
|
2
|
Wang Z, Li S, Wu Z, Kang Y, Xie S, Cai Z, Shan X, Li Q. Pulsed electromagnetic field-assisted reduced graphene oxide composite 3D printed nerve scaffold promotes sciatic nerve regeneration in rats. Biofabrication 2024; 16:035013. [PMID: 38604162 DOI: 10.1088/1758-5090/ad3d8a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Accepted: 04/11/2024] [Indexed: 04/13/2024]
Abstract
Peripheral nerve injuries can lead to sensory or motor deficits that have a serious impact on a patient's mental health and quality of life. Nevertheless, it remains a major clinical challenge to develop functional nerve conduits as an alternative to autologous grafts. We applied reduced graphene oxide (rGO) as a bioactive conductive material to impart electrophysiological properties to a 3D printed scaffold and the application of a pulsed magnetic field to excite the formation of microcurrents and induce nerve regeneration.In vitrostudies showed that the nerve scaffold and the pulsed magnetic field made no effect on cell survival, increased S-100βprotein expression, enhanced cell adhesion, and increased the expression level of nerve regeneration-related mRNAs.In vivoexperiments suggested that the protocol was effective in promoting nerve regeneration, resulting in functional recovery of sciatic nerves in rats, when they were damaged close to that of the autologous nerve graft, and increased expression of S-100β, NF200, and GAP43. These results indicate that rGO composite nerve scaffolds combined with pulsed magnetic field stimulation have great potential for peripheral nerve rehabilitation.
Collapse
Affiliation(s)
- Zichao Wang
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing 100081, People's Republic of China
- National Center for Stomatology, Beijing 100081, People's Republic of China
- National Clinical Research Center for Oral Diseases, Beijing 100081, People's Republic of China
- National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, People's Republic of China
- Beijing Key Laboratory of Digital Stomatology and NHC Key Laboratory of Digital Stomatology and NMPA Key Laboratory for Dental Materials, Beijing 100081, People's Republic of China
| | - Shijun Li
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing 100081, People's Republic of China
- National Center for Stomatology, Beijing 100081, People's Republic of China
- National Clinical Research Center for Oral Diseases, Beijing 100081, People's Republic of China
- National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, People's Republic of China
- Beijing Key Laboratory of Digital Stomatology and NHC Key Laboratory of Digital Stomatology and NMPA Key Laboratory for Dental Materials, Beijing 100081, People's Republic of China
| | - Zongxi Wu
- Department of Oral and Maxillofacial Surgery, Hospital of Stomatology, Sun Yat-sen University, Guangzhou 510030, People's Republic of China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510030, People's Republic of China
| | - Yifan Kang
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing 100081, People's Republic of China
- National Center for Stomatology, Beijing 100081, People's Republic of China
- National Clinical Research Center for Oral Diseases, Beijing 100081, People's Republic of China
- National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, People's Republic of China
- Beijing Key Laboratory of Digital Stomatology and NHC Key Laboratory of Digital Stomatology and NMPA Key Laboratory for Dental Materials, Beijing 100081, People's Republic of China
| | - Shang Xie
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing 100081, People's Republic of China
- National Center for Stomatology, Beijing 100081, People's Republic of China
- National Clinical Research Center for Oral Diseases, Beijing 100081, People's Republic of China
- National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, People's Republic of China
- Beijing Key Laboratory of Digital Stomatology and NHC Key Laboratory of Digital Stomatology and NMPA Key Laboratory for Dental Materials, Beijing 100081, People's Republic of China
| | - Zhigang Cai
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing 100081, People's Republic of China
- National Center for Stomatology, Beijing 100081, People's Republic of China
- National Clinical Research Center for Oral Diseases, Beijing 100081, People's Republic of China
- National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, People's Republic of China
- Beijing Key Laboratory of Digital Stomatology and NHC Key Laboratory of Digital Stomatology and NMPA Key Laboratory for Dental Materials, Beijing 100081, People's Republic of China
| | - Xiaofeng Shan
- Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, Beijing 100081, People's Republic of China
- National Center for Stomatology, Beijing 100081, People's Republic of China
- National Clinical Research Center for Oral Diseases, Beijing 100081, People's Republic of China
- National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, People's Republic of China
- Beijing Key Laboratory of Digital Stomatology and NHC Key Laboratory of Digital Stomatology and NMPA Key Laboratory for Dental Materials, Beijing 100081, People's Republic of China
| | - Qing Li
- National Center for Stomatology, Beijing 100081, People's Republic of China
- National Clinical Research Center for Oral Diseases, Beijing 100081, People's Republic of China
- National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, People's Republic of China
- Center of Digital Dentistry, Second Clinical Division, Peking University School and Hospital of Stomatology and National Center of Stomatology, Beijing 100081, People's Republic of China
- Beijing Key Laboratory of Digital Stomatology and NHC Key Laboratory of Digital Stomatology and NMPA Key Laboratory for Dental Materials, Beijing 100081, People's Republic of China
| |
Collapse
|
3
|
Hernández-Gallegos MA, Solorza-Feria J, Cornejo-Mazón M, Velázquez-Martínez JR, Rodríguez-Huezo ME, Gutiérrez-López GF, Hernández-Sánchez H. Protective Effect of Alginate Microcapsules with Different Rheological Behavior on Lactiplantibacillus plantarum 299v. Gels 2023; 9:682. [PMID: 37754363 PMCID: PMC10529054 DOI: 10.3390/gels9090682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 08/11/2023] [Accepted: 08/21/2023] [Indexed: 09/28/2023] Open
Abstract
Alginate encapsulation is a well-known technique used to protect microorganisms from adverse conditions. However, it is also known that the viscosity of the alginate is dependent on its composition and degree of polymerization and that thermal treatments, such as pasteurization and sterilization, can affect the structure of the polymer and decrease its protection efficiency. The goal of this study was to evaluate the protective effect of encapsulation, using alginates of different viscosities treated at different temperatures, on Lactiplantibacillus plantarum 299v under in vitro gastrointestinal conditions and cold storage at 4 °C and -15 °C, respectively. Steady- and dynamic-shear rheological tests were used to characterize the polymers. Thermal treatments profoundly affected the rheological characteristics of alginates with high and low viscosity. However, the solutions and gels of the low-viscosity alginate were more affected at a temperature of 117 °C. The capsules elaborated with high-viscosity alginate solution and pasteurized at 63 °C for 30 min provided better protection to the cells of L. plantarum 299v under simulated gastrointestinal and cold storage conditions.
Collapse
Affiliation(s)
- Minerva Aurora Hernández-Gallegos
- Departamento de Ingeniería Bioquímica, Escuela Nacional de Ciencias Biológicas, Instituto Politécnico Nacional, Av. Wilfrido Massieu esq. M. Stampa, UP Adolfo López Mateos, Ciudad de México CP 07738, Mexico; (M.A.H.-G.); (G.F.G.-L.)
- División Académica Multidisciplinaria de Jalpa de Méndez, Universidad Juárez Autónoma de Tabasco, Carretera Estatal Libre Villahermosa-Comalcalco Km 27 S/N, Ranchería, Jalpa de Méndez CP 86205, Mexico
| | - Javier Solorza-Feria
- Centro de Desarrollo de Productos Bióticos del IPN, Km 8.5 carr. Yautepec-Jojutla, Yautepec CP 62731, Mexico;
| | - Maribel Cornejo-Mazón
- Departamento de Biofísica, Escuela Nacional de Ciencias Biológicas, Instituto Politécnico Nacional, Carpio y Plan de Ayala, Col. Santo Tomás, Ciudad de México CP 11340, Mexico;
| | - José Rodolfo Velázquez-Martínez
- División Académica de Ciencias Agropecuarias, Universidad Juárez Autónoma de Tabasco, Carretera Villahermosa-Teapa Km. 25, Teapa CP 86291, Mexico;
| | - María Eva Rodríguez-Huezo
- División Ingeniería Química y Bioquímica, Tecnológico de Estudios Superiores de Ecatepec, Ecatepec, Estado de México CP 55010, Mexico;
| | - Gustavo F. Gutiérrez-López
- Departamento de Ingeniería Bioquímica, Escuela Nacional de Ciencias Biológicas, Instituto Politécnico Nacional, Av. Wilfrido Massieu esq. M. Stampa, UP Adolfo López Mateos, Ciudad de México CP 07738, Mexico; (M.A.H.-G.); (G.F.G.-L.)
| | - Humberto Hernández-Sánchez
- Departamento de Ingeniería Bioquímica, Escuela Nacional de Ciencias Biológicas, Instituto Politécnico Nacional, Av. Wilfrido Massieu esq. M. Stampa, UP Adolfo López Mateos, Ciudad de México CP 07738, Mexico; (M.A.H.-G.); (G.F.G.-L.)
| |
Collapse
|
4
|
S A Bento C, Gaspar MC, Coimbra P, de Sousa HC, E M Braga M. A review of conventional and emerging technologies for hydrogels sterilization. Int J Pharm 2023; 634:122671. [PMID: 36736965 DOI: 10.1016/j.ijpharm.2023.122671] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 01/26/2023] [Accepted: 01/28/2023] [Indexed: 02/04/2023]
Abstract
Hydrogels are extensively used in the biomedical field, as drug delivery systems, wound dressings, contact lenses or as scaffolds for tissue engineering. Due to their polymeric nature and the presence of high amounts of water in their structure, hydrogels generally present high sensitivity to terminal sterilization. The establishment of an efficient sterilization protocol that does not compromise the functional properties of the hydrogels is one of the challenges faced by researchers when developing a hydrogel for a specific application. Yet, until very recently this aspect was largely ignored in the literature. The present paper reviews the state of literature concerning hydrogels sterilization, compiling the main findings. Conventional terminal sterilization methods (heat sterilization, radiation sterilization, and gas sterilization) as well as emerging sterilization techniques (ozone, supercritical carbon dioxide) are covered. Considerations about aseptic processing are also included. Additionally, and as a framework, hydrogels' polymeric materials, types of networks, and main biomedical applications are summarily described.
Collapse
Affiliation(s)
- Cristiana S A Bento
- University of Coimbra, CIEPQPF, Department of Chemical Engineering, Rua Sílvio Lima, Pólo II - Pinhal de Marrocos, 3030-790 Coimbra, Portugal
| | - Marisa C Gaspar
- University of Coimbra, CIEPQPF, Department of Chemical Engineering, Rua Sílvio Lima, Pólo II - Pinhal de Marrocos, 3030-790 Coimbra, Portugal; Center for Innovative Care and Health Technology (ciTechCare), Polytechnic of Leiria, 2410-541 Leiria, Portugal
| | - Patrícia Coimbra
- University of Coimbra, CIEPQPF, Department of Chemical Engineering, Rua Sílvio Lima, Pólo II - Pinhal de Marrocos, 3030-790 Coimbra, Portugal
| | - Hermínio C de Sousa
- University of Coimbra, CIEPQPF, Department of Chemical Engineering, Rua Sílvio Lima, Pólo II - Pinhal de Marrocos, 3030-790 Coimbra, Portugal
| | - Mara E M Braga
- University of Coimbra, CIEPQPF, Department of Chemical Engineering, Rua Sílvio Lima, Pólo II - Pinhal de Marrocos, 3030-790 Coimbra, Portugal.
| |
Collapse
|
5
|
Off-the-shelf GMP-grade UC-MSCs as therapeutic drugs for the amelioration of CCl4-induced acute-on-chronic liver failure in NOD-SCID mice. Int Immunopharmacol 2022; 113:109408. [DOI: 10.1016/j.intimp.2022.109408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 10/16/2022] [Accepted: 10/28/2022] [Indexed: 11/10/2022]
|
6
|
Structured Data Storage for Data-Driven Process Optimisation in Bioprinting. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12157728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Bioprinting is a method to fabricate 3D models that mimic tissue. Future fields of application might be in pharmaceutical or medical context. As the number of applicants might vary between only one patient to manufacturing tissue for high-throughput drug screening, designing a process will necessitate a high degree of flexibility, robustness, as well as comprehensive monitoring. To enable quality by design process optimisation for future application, establishing systematic data storage routines suitable for automated analytical tools is highly desirable as a first step. This manuscript introduces a workflow for process design, documentation within an electronic lab notebook and monitoring to supervise the product quality over time or at different locations. Lab notes, analytical data and corresponding metadata are stored in a systematic hierarchy within the research data infrastructure Kadi4Mat, which allows for continuous, flexible data structuring and access management. To support the experimental and analytical workflow, additional features were implemented to enhance and build upon the functionality provided by Kadi4Mat, including browser-based file previews and a Python tool for the combined filtering and extraction of data. The structured research data management with Kadi4Mat enables retrospective data grouping and usage by process analytical technology tools connecting individual analysis software to machine-readable data exchange formats.
Collapse
|
7
|
Mojra A, Hooman K. Viscoelastic parameters of invasive breast cancer in correlation with porous structure and elemental analysis data. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 212:106482. [PMID: 34736165 DOI: 10.1016/j.cmpb.2021.106482] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Accepted: 10/14/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND AND OBJECTIVE Invasive ductal carcinoma (IDC) is the most common and aggressive type of breast cancer. As many clinical diagnoses are concerned with the tumor behavior at the compression, the IDC characterization using a compression test is performed in the present study. In the field of tissue characterization, most of the previous studies have focused on healthy and cancerous breast tissues at the cellular level; however, characterization of cancerous tissue at the tissue level has been under-represented, which is the target of the present study. METHODS Throughout this article, 18 IDC samples are tested using a ramp-relaxation test. The strain rate in the ramp phase is similar for all samples, whereas the strain level is set at 2,4 and 6%. The experimental stress-time data is interpolated by a viscoelastic model. Two relaxation times, as well as the instantaneous and long-term shear moduli, are calculated for each specimen. RESULTS The results show that the long-term and instantaneous shear moduli vary in the range of 0.31-17.03 kPa and 6.03-55.13 kPa, respectively. Our assessment of the viscoelastic parameters is accompanied by observing structural images of the IDCs and inspecting their elemental composition. It is concluded that IDCs with lower Magnesium to Calcium ratio (Mg:Ca) have smaller shear modulus and longer relaxation time, with a p-value of 0.001 and 0.01 for the correlation between Mg:Ca and long-term shear modulus, and Mg:Ca and early relaxation time. CONCLUSIONS Our identification of the IDC viscoelastic parameters can contribute to the IDC inspection at the tissue level. The results also provide useful information for modeling of breast cancer.
Collapse
Affiliation(s)
- Afsaneh Mojra
- Department of Mechanical Engineering, K. N. Toosi University of Technology, 15 Pardis St., Tehran 1991943344, Iran.
| | - Kamel Hooman
- School of Mechanical and Mining Engineering, University of Queensland, Brisbane, Qld 4072, Australia.
| |
Collapse
|
8
|
Farno M, Lamarche C, Tenailleau C, Cavalié S, Duployer B, Cussac D, Parini A, Sallerin B, Girod Fullana S. Low-energy electron beam sterilization of solid alginate and chitosan, and their polyelectrolyte complexes. Carbohydr Polym 2021; 261:117578. [PMID: 33766327 DOI: 10.1016/j.carbpol.2020.117578] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 12/18/2020] [Accepted: 12/28/2020] [Indexed: 01/24/2023]
Abstract
Polysaccharidic scaffolds hold great hope in regenerative medicine, however their sterilization still remains challenging since conventional methods are deleterious. Recently, electron beams (EB) have raised interest as emerging sterilization techniques. In this context, the aim of this work was to study the impact of EB irradiations on polysaccharidic macroporous scaffolds. The effects of continuous and pulsed low energy EB were examined on polysaccharidic or on polyelectrolyte complexes (PEC) scaffolds by SEC-MALLS, FTIR and EPR. Then the scaffolds' physicochemical properties: swelling, architecture and compressive modulus were investigated. Finally, sterility and in vitro biocompatibility of irradiated scaffolds were evaluated to validate the effectiveness of our approach. Continuous beam irradiations appear less deleterious on alginate and chitosan chains, but the use of a pulsed beam limits the time of irradiation and better preserve the architecture of PEC scaffolds. This work paves the way for low energy EB tailor-made sterilization of sensitive porous scaffolds.
Collapse
Affiliation(s)
- Maylis Farno
- Université Paul Sabatier, CIRIMAT Institut Carnot Chimie Balard CIRIMAT, Faculté de Pharmacie, Toulouse, France; Université Paul Sabatier, I2MC, Toulouse, France
| | | | - Christophe Tenailleau
- Université Paul Sabatier, CIRIMAT Institut Carnot Chimie Balard CIRIMAT, UPS, Toulouse, France
| | - Sandrine Cavalié
- Université Paul Sabatier, CIRIMAT Institut Carnot Chimie Balard CIRIMAT, Faculté de Pharmacie, Toulouse, France
| | - Benjamin Duployer
- Université Paul Sabatier, CIRIMAT Institut Carnot Chimie Balard CIRIMAT, UPS, Toulouse, France
| | | | | | | | - Sophie Girod Fullana
- Université Paul Sabatier, CIRIMAT Institut Carnot Chimie Balard CIRIMAT, Faculté de Pharmacie, Toulouse, France.
| |
Collapse
|
9
|
Wang AT, Zhao M, Feng Y, Jia H, Zhang L, Yu H, Li Z, Han Z, Han Z. Multifaceted Optimization of MSC-Based Formulation upon Sodium Iodoacetate-Induced Osteoarthritis Models by Combining Advantageous HA/PG Hydrogel and Fluorescent Tracer. Stem Cells Int 2021; 2021:1-13. [DOI: 10.1155/2021/8827212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023] Open
Abstract
Owing to the boundedness of conventional remedies upon articular cartilage for self-rehabilitation and the incrementally senior citizens, the incidence of osteoarthritis (OA) is increasing worldwide. Empirical studies have revealed the advantageous and promising potentials of mesenchymal stem/stromal cells (MSCs) on the refractory OA, whereas the deficiency of systematic and detailed exploration of MSC-based therapy largely hampers the large-scale applications in regenerative medicine. Herein, we initially utilized the monosodium iodoacetate- (MIA-) induced OA rabbit models and investigated the therapeutic effect of human umbilical cord-derived UC-MSCs at serial dose gradients with the splendid hyaluronic acid and/or propylene glycol hydrogels (HA, HA/PG), respectively. Afterwards, we turned to a dual-luciferase reporter tracing system and evaluated the spatiotemporal distribution and metabolokinetics of bifluorescence expressing UC-MSCs (BF-MSCs) in OA rats. Of the aforementioned trials, we verified that the combination of HA/PG and middle-dose MSCs (
cells/ml) eventually manifested the optimal efficacy on OA rabbits. Furthermore, with the aid of the bioluminescence imaging (BLI) technology for dynamic in vitro and in vivo tracking, we intuitively delineated the spatiotemporal distribution and therapeutic process of BF-MSCs in OA rats, which substantially confirmed the reinforcement of HA/PG on BF-MSCs for OA treatment. Collectively, our data conformably demonstrated that the middle dose of UC-MSCs combined with HA/PG hydrogel was sufficient for optimal MSC-based formulation for blocking OA progression and promoting cartilage repair, which supplied overwhelming new references and enlightened MSC-based therapeutic strategies for cartilage defects.
Collapse
Affiliation(s)
- Ai-tong Wang
- Cell Products of National Engineering Center & National Stem Cell Engineering Research Center, Tianjin IMCELL Stem Cell and Gene Technology Co., Ltd., Tianjin, China
| | - Meng Zhao
- Cell Products of National Engineering Center & National Stem Cell Engineering Research Center, Tianjin IMCELL Stem Cell and Gene Technology Co., Ltd., Tianjin, China
| | - Ying Feng
- Cell Products of National Engineering Center & National Stem Cell Engineering Research Center, Tianjin IMCELL Stem Cell and Gene Technology Co., Ltd., Tianjin, China
| | - Honghong Jia
- Cell Products of National Engineering Center & National Stem Cell Engineering Research Center, Tianjin IMCELL Stem Cell and Gene Technology Co., Ltd., Tianjin, China
| | - Leisheng Zhang
- The Postdoctoral Research Station, School of Medicine, Nankai University, Tianjin, China
- Precision Medicine Division, Health-Biotech (Tianjin) Stem Cell Research Institute Co., Ltd., Tianjin 301700, China
- State Key Laboratory of Experimental Hematology & National Clinical Research Center for Blood Disease, Institute of Hematology & Blood Diseases Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China
- Jiangxi Research Center of Stem Cell Engineering, Jiangxi Health-Biotech Stem Cell Technology Co., Ltd., Shangrao 334000, China
| | - Hao Yu
- Cell Products of National Engineering Center & National Stem Cell Engineering Research Center, Tianjin IMCELL Stem Cell and Gene Technology Co., Ltd., Tianjin, China
| | - Zongjin Li
- The Postdoctoral Research Station, School of Medicine, Nankai University, Tianjin, China
| | - Zhibo Han
- Cell Products of National Engineering Center & National Stem Cell Engineering Research Center, Tianjin IMCELL Stem Cell and Gene Technology Co., Ltd., Tianjin, China
- State Key Laboratory of Experimental Hematology & National Clinical Research Center for Blood Disease, Institute of Hematology & Blood Diseases Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China
| | - Zhongchao Han
- Cell Products of National Engineering Center & National Stem Cell Engineering Research Center, Tianjin IMCELL Stem Cell and Gene Technology Co., Ltd., Tianjin, China
- Precision Medicine Division, Health-Biotech (Tianjin) Stem Cell Research Institute Co., Ltd., Tianjin 301700, China
- State Key Laboratory of Experimental Hematology & National Clinical Research Center for Blood Disease, Institute of Hematology & Blood Diseases Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China
- Jiangxi Research Center of Stem Cell Engineering, Jiangxi Health-Biotech Stem Cell Technology Co., Ltd., Shangrao 334000, China
| |
Collapse
|
10
|
Chansoria P, Narayanan LK, Wood M, Alvarado C, Lin A, Shirwaiker RA. Effects of Autoclaving, EtOH, and UV Sterilization on the Chemical, Mechanical, Printability, and Biocompatibility Characteristics of Alginate. ACS Biomater Sci Eng 2020; 6:5191-5201. [PMID: 33455269 DOI: 10.1021/acsbiomaterials.0c00806] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Sterilization is a necessary step during the processing of biomaterials, but it can affect the materials' functional characteristics. This study characterizes the effects of three commonly used sterilization processes-autoclaving (heat-based), ethanol (EtOH; chemical-based), and ultraviolet (UV; radiation-based)-on the chemical, mechanical, printability, and biocompatibility properties of alginate, a widely used biopolymer for drug delivery, tissue engineering, and other biomedical applications. Sterility assessment tests showed that autoclaving was effective against Gram-positive and Gram-negative bacteria at loads up to 108 CFU/mL, while EtOH was the least effective. Nuclear magnetic-resonance spectroscopy showed that the sterilization processes did not affect the monomeric content in the alginate solutions. The differences in compressive stiffness of the three sterilized hydrogels were also not significant. However, autoclaving significantly reduced the molecular weight and polydispersity index, as determined via gel permeation chromatography, as well as the dynamic viscosity of alginate. Printability analyses showed that the sterilization process as well as the extrusion pressure and speed affected the number of discontinuities and spreading ratio in printed and cross-linked strands. Finally, human adipose-derived stem cells demonstrated over 90% viability in all sterilized hydrogels over 7 days, but the differences in cellular metabolic activity in the three groups were significant. Taken together, the autoclaving process, while demonstrating broad spectrum sterility effectiveness, also resulted in most notable changes in alginate's key properties. In addition to the specific results with the three sterilization processes and alginate, this study serves as a roadmap to characterize the interrelationships between sterilization processes, fundamental chemical properties, and resulting functional characteristics and processability of hydrogels.
Collapse
Affiliation(s)
- Parth Chansoria
- Edward P. Fitts Department of Industrial and Systems Engineering, North Carolina State University, Raleigh, North Carolina 27695-7906, United States.,Comparative Medicine Institute, North Carolina State University, Raleigh, North Carolina 27606, United States
| | - Lokesh Karthik Narayanan
- Edward P. Fitts Department of Industrial and Systems Engineering, North Carolina State University, Raleigh, North Carolina 27695-7906, United States.,Comparative Medicine Institute, North Carolina State University, Raleigh, North Carolina 27606, United States.,Department of Industrial and Manufacturing Engineering, North Dakota State University, Fargo, North Dakota 58105, United States
| | - Madison Wood
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Raleigh, North Carolina 27695, United States.,Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Claudia Alvarado
- Edward P. Fitts Department of Industrial and Systems Engineering, North Carolina State University, Raleigh, North Carolina 27695-7906, United States.,Comparative Medicine Institute, North Carolina State University, Raleigh, North Carolina 27606, United States
| | - Annie Lin
- Edward P. Fitts Department of Industrial and Systems Engineering, North Carolina State University, Raleigh, North Carolina 27695-7906, United States.,Comparative Medicine Institute, North Carolina State University, Raleigh, North Carolina 27606, United States
| | - Rohan A Shirwaiker
- Edward P. Fitts Department of Industrial and Systems Engineering, North Carolina State University, Raleigh, North Carolina 27695-7906, United States.,Comparative Medicine Institute, North Carolina State University, Raleigh, North Carolina 27606, United States.,Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
11
|
Zhou N, Ma X, Bernaerts KV, Ren P, Hu W, Zhang T. Expansion of Ovarian Cancer Stem-like Cells in Poly(ethylene glycol)-Cross-Linked Poly(methyl vinyl ether-alt-maleic acid) and Alginate Double-Network Hydrogels. ACS Biomater Sci Eng 2020; 6:3310-3326. [DOI: 10.1021/acsbiomaterials.9b01967] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Naizhen Zhou
- State Key Lab of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Xiaoe Ma
- State Key Lab of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Katrien V. Bernaerts
- Aachen-Maastricht Institute for Biobased Materials (AMIBM), Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
| | - Pengfei Ren
- State Key Lab of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Wanjun Hu
- State Key Lab of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Tianzhu Zhang
- State Key Lab of Bioelectronics, National Demonstration Center for Experimental Biomedical Engineering Education, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
12
|
Veryasova NN, Lazhko AE, Isaev DE, Grebenik EA, Timashev PS. Supercritical Carbon Dioxide—A Powerful Tool for Green Biomaterial Chemistry. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY B 2020. [DOI: 10.1134/s1990793119070236] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
13
|
Giz AS, Aydelik-Ayazoglu S, Catalgil-Giz H, Bayraktar H, Alaca BE. Stress relaxation and humidity dependence in sodium alginate-glycerol films. J Mech Behav Biomed Mater 2019; 100:103374. [DOI: 10.1016/j.jmbbm.2019.103374] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 07/12/2019] [Accepted: 07/26/2019] [Indexed: 10/26/2022]
|
14
|
Tridimensional alginate disks of tunable topologies for mammalian cell encapsulation. Anal Biochem 2019; 574:31-33. [DOI: 10.1016/j.ab.2019.03.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 03/17/2019] [Accepted: 03/18/2019] [Indexed: 11/20/2022]
|
15
|
Polymer-based carriers for ophthalmic drug delivery. J Control Release 2018; 285:106-141. [DOI: 10.1016/j.jconrel.2018.06.031] [Citation(s) in RCA: 74] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Revised: 06/23/2018] [Accepted: 06/25/2018] [Indexed: 12/22/2022]
|
16
|
Galante R, Pinto TJA, Colaço R, Serro AP. Sterilization of hydrogels for biomedical applications: A review. J Biomed Mater Res B Appl Biomater 2017; 106:2472-2492. [PMID: 29247599 DOI: 10.1002/jbm.b.34048] [Citation(s) in RCA: 98] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Revised: 11/04/2017] [Accepted: 11/12/2017] [Indexed: 12/19/2022]
Abstract
Despite the beneficial properties and outstanding potential of hydrogels for biomedical applications, several unmet challenges must be overcome, especially regarding to their known sensitivity to conventional sterilization methods. It is crucial for any biomaterial to withstand an efficient sterilization to obtain approval from regulatory organizations and to safely proceed to clinical trials. Sterility assurance minimizes the incidence of medical device-related infections, which still constitute a major concern in health care. In this review, we provide a detailed and comprehensive description of the published work from the past decade regarding the effects of sterilization on different types of hydrogels for biomedical applications. Advances in hydrogel production methods with simultaneous sterilization are also reported. Terminal sterilization methods can induce negative or positive effects on several material properties (e.g., aspect, size, color, chemical structure, mechanical integrity, and biocompatibility). Due to the complexity of factors involved (e.g., material properties, drug stability, sterilization conditions, and parameters), it is important to note the virtual impossibility of predicting the outcome of sterilization methods to determine a set of universal rules. Each system requires case-by-case testing to select the most suitable, effective method that allows for the main properties to remain unaltered. The impact of sterilization methods on the intrinsic properties of these systems is understudied, and further research is needed. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2472-2492, 2018.
Collapse
Affiliation(s)
- Raquel Galante
- Departamento de Farmácia, Faculdade de Ciências Farmacêuticas, Universidade de São Paulo, Butantã, São Paulo, Brazil.,Centro de Química Estrutural, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Terezinha J A Pinto
- Departamento de Farmácia, Faculdade de Ciências Farmacêuticas, Universidade de São Paulo, Butantã, São Paulo, Brazil
| | - Rogério Colaço
- Centro de Química Estrutural, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal.,Departamento de Engenharia Mecânica and IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Ana Paula Serro
- Centro de Química Estrutural, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal.,Centro de Investigação Interdisciplinar Egas Moniz, Instituto Superior de Ciências da Saúde Egas Moniz, Quinta da Granja, Monte de Caparica, Caparica, Portugal
| |
Collapse
|