Li Z, Luo T, Wang S, Jia H, Gong Q, Liu X, Sutcliffe MPF, Zhu H, Liu Q, Chen D, Xiong J, Teng Z. Mechanical and histological characteristics of aortic dissection tissues.
Acta Biomater 2022;
146:284-294. [PMID:
35367380 DOI:
10.1016/j.actbio.2022.03.042]
[Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 03/23/2022] [Accepted: 03/24/2022] [Indexed: 12/14/2022]
Abstract
AIMS
This study investigated the association between the macroscopic mechanical response of aortic dissection (AoD) flap, its fibre features, and patient physiological features and clinical presentations.
METHODS
Uniaxial test was performed with tissue strips in both circumferential and longitudinal directions from 35 patients with (AoD:CC) and without (AoD:w/oCC) cerebral/coronary complications, and 19 patients with rheumatic or valve-related heart diseases (RH). A Bayesian inference framework was used to estimate the expectation of material constants (C1, D1, and D2) of the modified Mooney-Rivlin strain energy density function. Histological examination was used to visualise the elastin and collagen in the tissue strips and image processing was performed to quantify their area percentages, fibre misalignment and waviness.
RESULTS
The elastin area percentage was negatively associated with age (p = 0.008), while collagen increased about 6% from age 40 to 70 (p = 0.03). Elastin fibre was less dispersed and wavier in old patients and no significant association was found between patient age and collagen fibre dispersion or waviness. Features of fibrous microstructures, either elastin or collagen, were comparable between AoD:CC and AoD:w/oCC group. Elastin and collagen area percentages were positively correlated with C1 and D2, respectively, while the elastin and collagen waviness were negatively correlated with C1 and D2, respectively. Elastin dispersion was negatively correlated to D2. Multivariate analysis showed that D2 was an effective parameter which could differentiate patient groups with different age and clinical presentations, as well as the direction of tissue strip.
CONCLUSION
Fibre dispersion and waviness in the aortic dissection flap changed with patient age and clinical presentations, and these can be captured by the material constants in the strain energy density function.
STATEMENT OF SIGNIFICANCE
Aortic dissection (AoD) is a severe cardiovascular disease. Understanding the mechanical property of intimal flap is essential for its risk evaluation. In this study, mechanical testing and histology examination were combined to quantify the relationship between mechanical presentations and microstructure features. A Bayesian inference framework was employed to estimate the expectation of the material constants in the modified Mooney-Rivlin constitutive equation. It was found that fibre dispersion and waviness in the AoD flap changed with patient age and clinical presentations, and these could be captured by the material constants. This study firstly demonstrated that the expectation of material constants can be used to characterise tissue microstructures and differentiate patients with different clinical presentations.
Collapse