Soliman MM, Islam MT, Chowdhury MEH, Alqahtani A, Musharavati F, Alam T, Alshammari AS, Misran N, Soliman MS, Mahmud S, Khandakar A. Advancement in total hip implant: a comprehensive review of mechanics and performance parameters across diverse novelties. J Mater Chem B 2023; 11:10507-10537. [PMID: 37873807 DOI: 10.1039/d3tb01469j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
The UK's National Joint Registry (NJR) and the American Joint Replacement Registry (AJRR) of 2022 revealed that total hip replacement (THR) is the most common orthopaedic joint procedure. The NJR also noted that 10-20% of hip implants require revision within 1 to 10 years. Most of these revisions are a result of aseptic loosening, dislocation, implant wear, implant fracture, and joint incompatibility, which are all caused by implant geometry disparity. The primary purpose of this review article is to analyze and evaluate the mechanics and performance factors of advancement in hip implants with novel geometries. The existing hip implants can be categorized based on two parts: the hip stem and the joint of the implant. Insufficient stress distribution from implants to the femur can cause stress shielding, bone loss, excessive micromotion, and ultimately, implant aseptic loosening due to inflammation. Researchers are designing hip implants with a porous lattice and functionally graded material (FGM) stems, femur resurfacing, short-stem, and collared stems, all aimed at achieving uniform stress distribution and promoting adequate bone remodeling. Designing hip implants with a porous lattice FGM structure requires maintaining stiffness, strength, isotropy, and bone development potential. Mechanical stability is still an issue with hip implants, femur resurfacing, collared stems, and short stems. Hip implants are being developed with a variety of joint geometries to decrease wear, improve an angular range of motion, and strengthen mechanical stability at the joint interface. Dual mobility and reverse femoral head-liner hip implants reduce the hip joint's dislocation limits. In addition, researchers reveal that femoral headliner joints with unidirectional motion have a lower wear rate than traditional ball-and-socket joints. Based on research findings and gaps, a hypothesis is formulated by the authors proposing a hip implant with a collared stem and porous lattice FGM structure to address stress shielding and micromotion issues. A hypothesis is also formulated by the authors suggesting that the utilization of a spiral or gear-shaped thread with a matched contact point at the tapered joint of a hip implant could be a viable option for reducing wear and enhancing stability. The literature analysis underscores substantial research opportunities in developing a hip implant joint that addresses both dislocation and increased wear rates. Finally, this review explores potential solutions to existing obstacles in developing a better hip implant system.
Collapse
Affiliation(s)
- Md Mohiuddin Soliman
- Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Mohammad Tariqul Islam
- Centre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Muhammad E H Chowdhury
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| | - Abdulrahman Alqahtani
- Department of Medical Equipment Technology, College of Applied, Medical Science, Majmaah University, Majmaah City 11952, Saudi Arabia
- Department of Biomedical Technology, College of Applied Medical Sciences in Al-Kharj, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia.
| | - Farayi Musharavati
- Department of Mechanical & Industrial Engineering, Qatar University, Doha 2713, Qatar.
| | - Touhidul Alam
- Pusat Sains Ankasa (ANGKASA), Institut Perubahan Iklim, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Selangor, Malaysia.
| | - Ahmed S Alshammari
- Department of Electrical Engineering, College of Engineering, University Hail, Hail 81481, Saudi Arabia.
- Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
| | - Norbahiah Misran
- Centre for Advanced Electronic and Communication Engineering, Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi 43600, Malaysia.
| | - Mohamed S Soliman
- Department of Electrical Engineering, College of Engineering, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
- Department of Electrical Engineering, Faculty of Energy Engineering, Aswan University, Aswan, 81528, Egypt
| | - Sakib Mahmud
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| | - Amith Khandakar
- Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar.
| |
Collapse
|
2
|
Pu J, Zhang Y, Zhang X, Zhang X, Yuan X, Wang Z, Zhang G, Cui W, Jin Z. Revealing the composite fretting-corrosion mechanisms of Ti6Al4V alloy against zirconia-toughened alumina ceramic in simulated body fluid. J Mech Behav Biomed Mater 2023; 146:106074. [PMID: 37591055 DOI: 10.1016/j.jmbbm.2023.106074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 08/06/2023] [Accepted: 08/13/2023] [Indexed: 08/19/2023]
Abstract
The composite fretting-corrosion damage due to combinations of radial, tangential, rotational, and other fretting causes local adverse tissue reactions and failure of artificial joints. Previous studies have mainly focused on the single fretting mode, while ignoring the coupled effects of multimode fretting. The fretting-corrosion mechanisms between the components are not yet fully understood. In this study, the tangential-radial composite fretting was realized by applying a normal alternating load to the tangential fretting. The composite fretting corrosion behavior of zirconia toughened alumina ceramic/Ti6Al4V alloy used for the head-neck interface of an artificial hip joint under simulated body fluid was investigated. The effects of displacement and alternating load amplitude were considered. The alternating load amplitude was given by the maximum normal load and minimum normal load ratio R. The results showed that the composite fretting damage mechanisms of this pair were mainly abrasion and tribocorrosion. Cracking also existed under large displacement. The effect of alternating load on fretting corrosion was found to be mainly caused by changes in the contact area and instantaneous contact state. In addition, the alternating load during the composite fretting promoted the formation of the three-body layer in the contact area. A decrease in load ratio caused fretting to change from gross to partial slip. In the case of small displacement, the load ratio had little effect on the friction work or wear scar profile. The corrosion rate of materials and the concentration of metal ions released into the solution increased as load ratio decreased. In cases of large and medium displacement, load ratio reduction increased the friction work and expanded the wear scar. The reduction in load ratio also caused the corrosion rate of the material to increase and then decrease, and the metal ion concentration decreased.
Collapse
Affiliation(s)
- Jian Pu
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China
| | - Yali Zhang
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China.
| | - Xiaogang Zhang
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China
| | - Xiaoyu Zhang
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China
| | - Xinlu Yuan
- School of Mechanical Engineering, Chengdu University, Sichuan, Chengdu, 610106, China
| | - Zhongyi Wang
- Jiangsu Key Laboratory of Oral Diseases, Affiliated Hospital of Stomatology of Nanjing Medical University, Jiangsu Nanjing, Jiangsu, Nanjing, 210029, China
| | - Guoxian Zhang
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China
| | - Wen Cui
- Beijing AKEC Medical Co., Ltd., Beijing, 102200, China; School of Materials Science and Engineering, Peking University, Beijing, 100871, China
| | - Zhongmin Jin
- School of Mechanical Engineering, Southwest Jiaotong University, Sichuan, Chengdu, 610031, China; School of Mechanical Engineering, University of Leeds, Leeds, LS2 9JT, UK
| |
Collapse
|
3
|
Kong D, Wang Q, Huang J, Zhang Z, Wang X, Han Q, Shi Y, Ji R, Li Y. Design and manufacturing of biomimetic scaffolds for bone repair inspired by bone trabeculae. Comput Biol Med 2023; 165:107369. [PMID: 37625259 DOI: 10.1016/j.compbiomed.2023.107369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/13/2023] [Accepted: 08/12/2023] [Indexed: 08/27/2023]
Abstract
Porous scaffold (PorS) implants, particularly those that mimic the structural features of natural cancellous bone (NCanB), are increasingly essential for the treatment of large-area bone defects. However, the mechanical properties of NCanB-based bionic bone scaffold (BioS) and its performance as a bone repair material have not been fully explored. This study investigates the effect of bionic structure parameters on the mechanical properties and bone reconstruction performance of BioS. Using laser powder bed fusion (L-PBF) technology, different BioS with various structural parameters were created and evaluated using Micro-CT, compression testing, Finite Element (FE) Simulation, and computational fluid dynamics (CFD), and compared to commonly used clinical PorS. Assess the capacity of the BioS scaffold to support and enhance bone reconstruction following implantation through the evaluation of its mechanical properties, permeability, and fluid shear stress (FSS). BioS-85-90 and BioS-80-50 showed suitable mechanical properties, performed well in FE simulation of implantation, demonstrated outstanding abilities for osteoinductive ingrowth and bone tissue differentiation, and proved to be reliable materials for the reconstruction of bone defects. Therefore, BioS shows significant potential for clinical application as a bone reconstruction material, providing a solid foundation for the integration of tissue engineering and bionic design.
Collapse
Affiliation(s)
- Deyin Kong
- Key Laboratory of Bionic Engineering, Ministry of Education, College of Biological and Agricultural Engineering, Jilin University, Changchun, China
| | - Qing Wang
- Key Laboratory of Bionic Engineering, Ministry of Education, College of Biological and Agricultural Engineering, Jilin University, Changchun, China
| | - Jiangeng Huang
- Key Laboratory of Bionic Engineering, Ministry of Education, College of Biological and Agricultural Engineering, Jilin University, Changchun, China
| | - Zhihui Zhang
- Key Laboratory of Bionic Engineering, Ministry of Education, College of Biological and Agricultural Engineering, Jilin University, Changchun, China; Liaoning Academy of Materials, Shenyang 110167, China.
| | - Xiebin Wang
- Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, Shandong University, Jinan, China
| | - Qing Han
- Department of Orthopedics, Second Hospital of Jilin University, Changchun, China
| | - Yanbin Shi
- School of Mechanical & Automotive Engineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, China
| | - Ran Ji
- Key Laboratory of Bionic Engineering, Ministry of Education, College of Biological and Agricultural Engineering, Jilin University, Changchun, China
| | - Yiling Li
- Key Laboratory of Bionic Engineering, Ministry of Education, College of Biological and Agricultural Engineering, Jilin University, Changchun, China
| |
Collapse
|
4
|
Martelli A, Erani P, Pazzagli N, Cannillo V, Baleani M. Surface Analysis of Ti-Alloy Micro-Grooved 12/14 Tapers Assembled to Non-Sleeved and Sleeved Ceramic Heads: A Comparative Study of Retrieved Hip Prostheses. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1067. [PMID: 36770073 PMCID: PMC9920329 DOI: 10.3390/ma16031067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 01/16/2023] [Accepted: 01/18/2023] [Indexed: 06/18/2023]
Abstract
Ti6Al4V titanium alloy (Ti-alloy) sleeved ceramic heads have become widely used in revision surgery when the hip stem is left in situ. This solution guarantees a new junction between the bore of the ceramic head and the Ti-alloy sleeve, regardless of any possible, slight surface damage to the Ti-alloy taper of the stem. However, this solution introduces an additional Ti-alloy/Ti-alloy interface pairing, which is potentially susceptible to mechanically assisted crevice corrosion. This study evaluated both qualitatively and quantitatively the damage that occurred in vivo on Ti-alloy micro-grooved 12/14 tapers of (i) primary implants with non-sleeved ceramic heads (Group 1), (ii) secondary implants with non-sleeved ceramic heads (Group 2), and (iii) secondary implants with sleeved ceramic heads (Group 3). A total of 45 explants-15 for each group, including short-, medium- and long-neck heads-underwent optical evaluation for surface damage (Goldberg scoring), surface roughness analysis, and SEM/EDX analysis. The Goldberg scores did not reveal different patterns in the tapers' surface damage; surface damage was classified as absent or mild (surface damage score ≤2) in 94%, another 94%, and 92% of the analysed regions for Group 1, Group 2, and Group 3, respectively. Small but significant differences in morphological changes occurred in the tapers of the three groups: reductions no greater than a few percentage points in median values of roughness parameters were found in Group 1 and Group 2, while negligible changes were found in Group 3. SEM/EDX analysis revealed little (i.e., a slight increase in the oxygen content) to undetectable changes in the chemical composition on the Ti-alloy surface independently of the group. These results suggest that the Ti-alloy/Ti-alloy sleeve/taper junction is only mildly susceptible to mechanically assisted crevice corrosion. Assembling a sleeved ceramic head, with variable neck lengths up to a "long-neck", to a Ti-alloy micro-grooved 12/14 taper of a stem left in situ does not seem to increase the risk of revision due to trunnionosis, as long as junction stability (i.e., the proper seating of the sleeved ceramic head on the 12/14 taper) is achieved intraoperatively.
Collapse
Affiliation(s)
- Andrea Martelli
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
- Dipartimento di Ingegneria Enzo Ferrari, Università degli Studi di Modena e Reggio Emilia, 41125 Modena, Italy
| | - Paolo Erani
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Nicola Pazzagli
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| | - Valeria Cannillo
- Dipartimento di Ingegneria Enzo Ferrari, Università degli Studi di Modena e Reggio Emilia, 41125 Modena, Italy
| | - Massimiliano Baleani
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy
| |
Collapse
|
5
|
Nafi MA, Jahan MP. Functional Surface Generation by EDM-A Review. MICROMACHINES 2022; 14:115. [PMID: 36677180 PMCID: PMC9865250 DOI: 10.3390/mi14010115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 12/27/2022] [Accepted: 12/27/2022] [Indexed: 06/17/2023]
Abstract
Electro-discharge machining (EDM) removes electrically conductive materials by high frequency spark discharges between the tool electrode and the workpiece in the presence of a dielectric liquid. Being an electrothermal process and with melting and evaporation being the mechanisms of material removal, EDM suffers from migration of materials between the tool and the workpiece. Although unwanted surface modification was considered a challenge in the past for many applications, this inherent nature of the EDM process has recently become of interest to the scientific community. As a result, researchers have been focusing on using the EDM process for surface modification and coating by targeted surface engineering. In order to engineer a surface or generate functional coatings using the electro-discharge process, proper knowledge of the EDM process and science of electro-discharge surface modification must be understood. This paper aims to provide an overview of the electro-discharge surface modification and coating processes, thus assisting the readers on exploring potential applications of EDM-based techniques of surface engineering and coating generation. This review starts with a brief introduction to the EDM process, the physics behind the EDM process, and the science of the surface modification process in EDM. The paper then discusses the reasons and purposes of surface modification and coating practices. The common EDM-based techniques reported in the literature for producing coatings on the surface are discussed with their process mechanisms, important parameters, and design considerations. The characterization techniques used for the analysis of modified surfaces and coating layers, as well as the tribological and surface properties of modified surfaces or coatings are discussed. Some of the important applications of EDM-based surface modification and coating processes are generating surfaces for protective coating, for aesthetic purposes, for enhancing the biocompatibility of implants, for improving corrosion resistance, for improving wear resistance, and for improving tribological performance. The current state of the research in these application areas is discussed with examples. Finally, suggestions are provided on future research directions and innovative potential new applications of the electro-discharge-based surface engineering and coating processes.
Collapse
Affiliation(s)
| | - Muhammad Pervej Jahan
- Department of Mechanical and Manufacturing Engineering, Miami University, Oxford, OH 45056, USA
| |
Collapse
|
6
|
Feyzi M, Fallahnezhad K, Taylor M, Hashemi R. An Overview of the Stability and Fretting Corrosion of Microgrooved Necks in the Taper Junction of Hip Implants. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8396. [PMID: 36499893 PMCID: PMC9735617 DOI: 10.3390/ma15238396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/21/2022] [Accepted: 11/22/2022] [Indexed: 06/17/2023]
Abstract
Fretting corrosion at the head-neck interface of modular hip implants, scientifically termed trunnionosis/taperosis, may cause regional inflammation, metallosis, and adverse local tissue reactions. The severity of such a deleterious process depends on various design parameters. In this review, the influence of surface topography (in some cases, called microgrooves/ridges) on the overall performance of the microgrooved head-neck junctions is investigated. The methodologies together with the assumptions and simplifications, as well as the findings from both the experimental observations (retrieval and in vitro) and the numerical approaches used in previous studies, are presented and discussed. The performance of the microgrooved junctions is compared to those with a smooth surface finish in two main categories: stability and integrity; wear, corrosion, and material loss. Existing contradictions and disagreements among the reported results are reported and discussed in order to present a comprehensive picture of the microgrooved junctions. The current research needs and possible future research directions on the microgrooved junctions are also identified and presented.
Collapse
|
7
|
Diaz-Lopez R, Wen P, Shelton J. Influence of taper design and loading on taper micromotion. J Mech Behav Biomed Mater 2022; 128:105106. [DOI: 10.1016/j.jmbbm.2022.105106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 10/05/2021] [Accepted: 01/25/2022] [Indexed: 11/24/2022]
|
8
|
Wight CM, Whyne CM, Bogoch ER, Zdero R, Chapman RM, van Citters DW, Walsh WR, Schemitsch E. Effect of head size and rotation on taper corrosion in a hip simulator. Bone Jt Open 2021; 2:1004-1016. [PMID: 34825826 PMCID: PMC8636299 DOI: 10.1302/2633-1462.211.bjo-2021-0147.r1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
AIMS This study investigates head-neck taper corrosion with varying head size in a novel hip simulator instrumented to measure corrosion related electrical activity under torsional loads. METHODS In all, six 28 mm and six 36 mm titanium stem-cobalt chrome head pairs with polyethylene sockets were tested in a novel instrumented hip simulator. Samples were tested using simulated gait data with incremental increasing loads to determine corrosion onset load and electrochemical activity. Half of each head size group were then cycled with simulated gait and the other half with gait compression only. Damage was measured by area and maximum linear wear depth. RESULTS Overall, 36 mm heads had lower corrosion onset load (p = 0.009) and change in open circuit potential (OCP) during simulated gait with (p = 0.006) and without joint movement (p = 0.004). Discontinuing gait's joint movement decreased corrosion currents (p = 0.042); however, wear testing showed no significant effect of joint movement on taper damage. In addition, 36 mm heads had greater corrosion area (p = 0.050), but no significant difference was found for maximum linear wear depth (p = 0.155). CONCLUSION Larger heads are more susceptible to taper corrosion; however, not due to frictional torque as hypothesized. An alternative hypothesis of taper flexural rigidity differential is proposed. Further studies are necessary to investigate the clinical significance and underlying mechanism of this finding. Cite this article: Bone Jt Open 2021;2(11):1004-1016.
Collapse
Affiliation(s)
- Christian M Wight
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Cari M Whyne
- Orthopaedic Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Earl R Bogoch
- Department of Surgery, University of Toronto, Brookfield Chair in Fracture Prevention, Toronto, Ontario, Canada
| | - Radovan Zdero
- London Health Science Centre, Western University, London, Ontario, Canada
| | - Ryan M Chapman
- London Health Science Centre, Western University, London, Ontario, Canada
| | - Douglas W van Citters
- Thayer School of Engineering at Dartmouth College, Western University, Hanover, New Hampshire, USA
| | - William R Walsh
- Surgical and Orthopaedic Research Laboratory, UNSW Prince of Wales Clinical School, Randwick, New South Wales, Australia
| | - Emil Schemitsch
- Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, University of Western Ontario, London, Ontario, Canada
| |
Collapse
|
9
|
Feyzi M, Fallahnezhad K, Taylor M, Hashemi R. The mechanics of head-neck taper junctions: What do we know from finite element analysis? J Mech Behav Biomed Mater 2021; 116:104338. [PMID: 33524892 DOI: 10.1016/j.jmbbm.2021.104338] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 12/16/2020] [Accepted: 01/15/2021] [Indexed: 12/18/2022]
Abstract
Modular hip implants are widely used in hip arthroplasty because of the advantages they can offer such as flexibility in material combinations and geometrical adjustments. The mechanical environment of the modular junction in the body is quite challenging due to the complex and varying off-axial mechanical loads of physical activities applied to a tapered interface of two contacting materials (head and neck) assembled by an impact force intraoperatively. Experimental analogies to the in-vivo condition of the taper junction are complex, expensive and time-consuming to implement; hence, computational simulations have been a preferred approach taken by researchers for studying the mechanics of these modular junctions that can help us understand their failure mechanisms and improve their design and longevity after implantation. This paper provides a clearer insight into the mechanics of the head-neck taper junction through a careful review on the finite element studies of the junction and their findings. The effects of various factors on the mechanical outputs namely: stresses, micromotions, and contact situations are reviewed and discussed. Also, the simulation methodology of the studies in the literature is compared. Research opportunities for future are scrutinised through tabulating data and information that have been carefully retrieved form the reported findings.
Collapse
Affiliation(s)
- Mohsen Feyzi
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Khosro Fallahnezhad
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Mark Taylor
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Reza Hashemi
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia.
| |
Collapse
|
10
|
Feyzi M, Fallahnezhad K, Taylor M, Hashemi R. A review on the finite element simulation of fretting wear and corrosion in the taper junction of hip replacement implants. Comput Biol Med 2020; 130:104196. [PMID: 33516962 DOI: 10.1016/j.compbiomed.2020.104196] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 12/14/2020] [Accepted: 12/20/2020] [Indexed: 12/13/2022]
Abstract
Taperosis/trunnionosis is a scientific term for describing tribocorrosion (fretting corrosion) at the head-neck taper junction of hip implants where two contacting surfaces are undergone oscillatory micromotions while being exposed to the body fluid. Detached ions and emitted debris, as a result of taperosis, migrate to the surrounding tissues and can cause inflammation, infection, and aseptic loosening with an ultimate possibility of implant failure. Improving the tribocorrosion performance of the head-neck junction in the light of minimising the surface damage and debris requires a better understanding of taperosis. Given its complexity associated with both the mechanical and electrochemical aspects, computational methods such as the finite element method have been recently employed for analysing fretting wear and corrosion in the taper junction. To date, there have been more efforts on the fretting wear simulation when compared with corrosion. This is because of the mechanical nature of fretting wear which is probably more straightforward for modelling. However, as a recent research advancement, corrosion has been a focus to be implemented in the finite element modelling of taper junctions. This paper aims to review finite element studies related to taperosis in the head-neck junction to provide a detailed understanding of the design parameters and their role in this failure mechanism. It also reviews and discusses the methodologies developed for simulating this complex process in the taper junction along with the simplifications, assumptions and findings reported in these studies. The current needs and future research opportunities and directions in this field are then identified and presented.
Collapse
Affiliation(s)
- Mohsen Feyzi
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Khosro Fallahnezhad
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Mark Taylor
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia
| | - Reza Hashemi
- College of Science and Engineering, Medical Device Research Institute, Flinders University, Tonsley, SA, 5042, Australia.
| |
Collapse
|
11
|
Bechstedt M, Gustafson JA, Mell SP, Gührs J, Morlock MM, Levine BR, Lundberg HJ. Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers. J Biomech 2020; 103:109689. [PMID: 32139099 DOI: 10.1016/j.jbiomech.2020.109689] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 02/21/2020] [Accepted: 02/23/2020] [Indexed: 10/24/2022]
Abstract
Implant failure due to fretting-corrosion of head-neck modular junctions is a rising problem in total hip arthroplasty. Fretting-corrosion initiates when micromotion leads to metal release; however, factors leading to micromotion, such as microgrooves on the stem taper, are not fully understood. The purpose of this study is to describe a finite element analysis technique to determine head-neck contact mechanics and investigate the effect of stem taper microgroove height during head-neck assembly. Two-dimensional axisymmetric finite element models were created. Models were created for a ceramic femoral head and a CoCrMo femoral head against Ti6Al4V stem tapers and compared to available data from prior experiments. Stem taper microgroove height was investigated with a generic 12/14 model. Head-neck assembly was performed to four maximum loads (500 N, 2000 N, 4000 N, 8000 N). For the stem taper coupled with the ceramic head, the number of microgrooves in contact and plastically deformed differed by 2.5 microgrooves (4%) and 6.5 microgrooves (11%), respectively, between the finite element models and experiment. For the stem taper coupled with the CoCrMo head, all microgrooves were in contact after all assembly loads in the finite element model due to an almost identical conical angle between the taper surfaces. In the experiments, all grooves were only in contact for the 8000 N assembly load. Contact area, plastic (permanent) deformation, and contact pressure increased with increasing assembly loads and deeper microgrooves. The described modeling technique can be used to investigate the relationship between implant design factors, allowing for optimal microgroove design within material couples.
Collapse
Affiliation(s)
- Maren Bechstedt
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany
| | - Jonathan A Gustafson
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States
| | - Steven P Mell
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States
| | - Julian Gührs
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany
| | - Michael M Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, 21073 Hamburg, Germany
| | - Brett R Levine
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States
| | - Hannah J Lundberg
- Department of Orthopedic Surgery, Rush University Medical Center, 1611 W Harrison St Suite 201, Chicago, IL 60612, United States.
| |
Collapse
|
12
|
On the Corrosion Behaviour of Low Modulus Titanium Alloys for Medical Implant Applications: A Review. METALS 2019. [DOI: 10.3390/met9080878] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The corrosion behaviour of new generation titanium alloys (β-type with low modulus) for medical implant applications is of paramount importance due to their possible detrimental effects in the human body such as release of toxic metal ions and corrosion products. In spite of remarkable advances in improving the mechanical properties and reducing the elastic modulus, limited studies have been done on the electrochemical corrosion behaviour of various types of low modulus titanium alloys including the effect of different beta-stabilizer alloying elements. This development should aim for a good balance between mechanical properties, design features, metallurgical aspects and, importantly, corrosion resistance. In this article, we review several significant factors that can influence the corrosion resistance of new-generation titanium alloys such as fabrication process, body electrolyte properties, mechanical treatments, alloying composition, surface passive layer, and constituent phases. The essential factors and their critical features are discussed. The impact of various amounts of α and β phases in the microstructure, their interactions, and their dissolution rates on the surface passive layer and bulk corrosion behaviour are reviewed and discussed in detail. In addition, the importance of different corrosion types for various medical implant applications is addressed in order to specify the significance of every corrosion phenomenon in medical implants.
Collapse
|
13
|
The Influence of Assembly Force on the Material Loss at the Metallic Head-Neck Junction of Hip Implants Subjected to Cyclic Fretting Wear. METALS 2019. [DOI: 10.3390/met9040422] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The impaction force required to assemble the head and stem components of hip implants is proven to play a major role in the mechanics of the taper junction. However, it is not clear if the assembly force could have an effect on fretting wear, which normally occurs at the junction. In this study, an adaptive finite element model was developed for a CoCr/CoCr head-neck junction with an angular mismatch of 0.01° in order to simulate the fretting wear process and predict the material loss under various assembly forces and over a high number of gait cycles. The junction was assembled with 2, 3, 4, and 5 kN and then subjected to 1,025,000 cycles of normal walking gait loading. The findings showed that material removal due to fretting wear increased when raising the assembly force. High assembly forces induced greater contact pressures over larger contact regions at the interface, which, in turn, resulted in more material loss and wear damage to the surface when compared to lower assembly forces. Although a high assembly force (greater than 4 kN) can further improve the initial strength and stability of the taper junction, it appears that it also increases the degree of fretting wear. Further studies are needed to investigate the assembly force in the other taper designs, angular mismatches, and material combinations.
Collapse
|