1
|
Muniz NO, Baudequin T. Biomimetic and Nonbiomimetic Approaches in Dura Substitutes: The Influence of Mechanical Properties. TISSUE ENGINEERING. PART B, REVIEWS 2024. [PMID: 38874958 DOI: 10.1089/ten.teb.2024.0079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2024]
Abstract
The dura mater, the furthest and strongest layer of the meninges, is crucial for protecting the brain and spinal cord. Its biomechanical behavior is vital, as any alterations can compromise biological functions. In recent decades, interest in the dura mater has increased due to the need for hermetic closure of dural defects prompting the development of several substitutes. Collagen-based dural substitutes are common commercial options, but they lack the complex biological and structural elements of the native dura mater, impacting regeneration and potentially causing complications like wound/postoperative infection and cerebrospinal fluid (CSF) leakage. To face this issue, recent tissue engineering approaches focus on creating biomimetic dura mater substitutes. The objective of this review is to discuss whether mimicking the mechanical properties of native tissue or ensuring high biocompatibility and bioactivity is more critical in developing effective dural substitutes, or if both aspects should be systematically linked. After a brief description of the properties and architecture of the native cranial dura, we describe the advantages and limitations of biomimetic dura mater substitutes to better understand their relevance. In particular, we consider biomechanical properties' impact on dura repair's effectiveness. Finally, the obstacles and perspectives for developing the ideal dural substitute are explored.
Collapse
Affiliation(s)
- Nathália Oderich Muniz
- Université de Technologie de Compiègne, CNRS, Biomechanics and Bioengineering, Centre de recherche Royallieu, Compiègne Cedex, France
| | - Timothée Baudequin
- Université de Technologie de Compiègne, CNRS, Biomechanics and Bioengineering, Centre de recherche Royallieu, Compiègne Cedex, France
| |
Collapse
|
2
|
Siess M, Steinke H, Zwirner J, Hammer N. On a potential morpho-mechanical link between the gluteus maximus muscle and pelvic floor tissues. Sci Rep 2023; 13:22901. [PMID: 38129498 PMCID: PMC10739724 DOI: 10.1038/s41598-023-50058-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 12/14/2023] [Indexed: 12/23/2023] Open
Abstract
Stress urinary incontinence presents a condition not only found in female elderlies, but also in young athletes participating in high-impact sports such as volleyball or trampolining. Repeated jumps appear to be a predisposing factor. Yet the pathophysiology remains incompletely elucidated to date; especially with regard to the influence of the surrounding buttock tissues including gluteus maximus. The present study assessed the morpho-mechanical link between gluteus maximus and the pelvic floor female bodies. 25 pelves obtained from Thiel embalmed females were studied in a supine position. Strands of tissues connecting gluteus maximus with the pelvic floor obtained from 20 sides were assessed mechanically. Plastinates were evaluated to verify the dissection findings. In total, 49 hemipelves were included for data acquisition. The fascia of gluteus maximus yielded connections to the subcutaneous tissues, the fascia of the external anal sphincter and that of obturator internus and to the fascia of the urogenital diaphragm. The connection between gluteus maximus and the urogenital diaphragm withstood an average force of 23.6 ± 17.3 N. Cramér φ analyses demonstrated that the connections of the fasciae connecting gluteus maximus with its surroundings were consistent in the horizontal and sagittal planes, respectively. In conclusion, gluteus maximus is morphologically densely linked to the pelvic floor via strands of connective tissues investing the adjacent muscles. Though gluteus maximus has also been reported to facilitate urinary continence, the here presented morpho-mechanical link suggests that it may also have the potential to contribute to urinary stress incontinence. Future research combining clinical imaging with in-situ testing may help substantiate the potential influence from a clinical perspective.
Collapse
Affiliation(s)
- Maximilian Siess
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Auenbruggerplatz 25, 8036, Graz, Austria
| | - Hanno Steinke
- Institute of Anatomy, University of Leipzig, Leipzig, Germany
| | - Johann Zwirner
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Niels Hammer
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Auenbruggerplatz 25, 8036, Graz, Austria.
- Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany.
- Medical Branch, Fraunhofer Institute for Machine Tools and Forming Technology (IWU), Chemnitz, Germany.
| |
Collapse
|
3
|
Niestrawska JA, Rodewald M, Schultz C, Quansah E, Meyer-Zedler T, Schmitt M, Popp J, Tomasec I, Ondruschka B, Hammer N. Morpho-mechanical mapping of human dura mater microstructure. Acta Biomater 2023; 170:86-96. [PMID: 37598794 DOI: 10.1016/j.actbio.2023.08.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 07/20/2023] [Accepted: 08/11/2023] [Indexed: 08/22/2023]
Abstract
The human dura mater is known to impact vastly traumatic brain injury mechanopathology. In spite of this involvement, dura mater is typically neglected in computational and physical human head models. The lack of location-dependent microstructural and related mechanical data of dura mater may be considered a rationale behind this simplification. The anisotropic nature of dura mater under various loading conditions so far remains unelucidated. Furthermore, principal collagen fiber orientation is yet to be quantified for a morpho-mechanically-informed material model on the dura mater. This study aims to assess how location-dependent mechanical anisotropy is linked to principal collagen fiber orientation. Uniaxial extension tests were performed in a heated tissue bath for 60 samples from six individuals and correlated to the three-dimensional collagen structure in four individuals using second-harmonic generation (SHG) imaging. Failure stress and stretch at failure, elastic modulus, and a microstructurally motivated material model were integrated to examine local differences in dura mater morpho-mechanics. The quantitative observation of collagen fiber orientation and dispersion confirmed that collagen is highly aligned in the human dura mater and that both fiber orientation and dispersion differ depending on the location investigated. This observation provides a possible explanation for the previously observed isotropic mechanical behavior, as the main collagen fiber direction is not oriented along the anterior-posterior or medial-lateral direction at most of the mapped locations. Additionally, these site-dependent structural properties have implications for the mechanical load response and therefore potentially for the regional functions dura mater has to fulfill. The here chosen non-symmetrical fiber dispersion material model fits the data well and provides a comprehensive parameter base for further studies and future finite element models. STATEMENT OF SIGNIFICANCE: The human dura mater greatly affects traumatic brain injury mechanisms, but it is often ignored in computational and physical head models. This is because there is a lack of detailed microstructural and mechanical data specific to the dura mater. Its anisotropic nature and collagen fiber orientation have not been fully understood, hindering the development of an accurate material model. Hence, this study combines morphological data on collagen fiber orientation and dispersion at multiple locations of human cranial dura mater, and links microstructure to location-specific load-displacement behavior. It provides microstructurally informed mechanical information towards realistic head models for predicting location-dependent tissue behavior and failure for assessing brain injury and graft material development.
Collapse
Affiliation(s)
- Justyna Anna Niestrawska
- Division of Macroscopic and Clinical Anatomy Gottfried Schatz Research Center, Medical University of Graz, Austria.
| | - Marko Rodewald
- Leibniz Institute of Photonic Technology, Member of Leibniz Health Technologies, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena Germany; Institute of Physical Chemistry (IPC) and Abbe Center of Photonics (ACP), Friedrich Schiller University Jena, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena, Germany
| | - Constanze Schultz
- Leibniz Institute of Photonic Technology, Member of Leibniz Health Technologies, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena Germany
| | - Elsie Quansah
- Leibniz Institute of Photonic Technology, Member of Leibniz Health Technologies, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena Germany; Institute of Physical Chemistry (IPC) and Abbe Center of Photonics (ACP), Friedrich Schiller University Jena, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena, Germany
| | - Tobias Meyer-Zedler
- Leibniz Institute of Photonic Technology, Member of Leibniz Health Technologies, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena Germany
| | - Michael Schmitt
- Institute of Physical Chemistry (IPC) and Abbe Center of Photonics (ACP), Friedrich Schiller University Jena, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena, Germany
| | - Jürgen Popp
- Leibniz Institute of Photonic Technology, Member of Leibniz Health Technologies, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena Germany; Institute of Physical Chemistry (IPC) and Abbe Center of Photonics (ACP), Friedrich Schiller University Jena, Member of the Leibniz Centre for Photonics in Infection Research (LPI), Jena, Germany
| | - Igor Tomasec
- Division of Macroscopic and Clinical Anatomy Gottfried Schatz Research Center, Medical University of Graz, Austria
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Niels Hammer
- Division of Macroscopic and Clinical Anatomy Gottfried Schatz Research Center, Medical University of Graz, Austria; Department of Orthopaedic and Trauma Surgery University of Leipzig, Leipzig, Germany; Fraunhofer IWU, Dresden, Germany
| |
Collapse
|
4
|
Hammer N, Ondruschka B, Berghold A, Kuenzer T, Pregartner G, Scholze M, Schulze-Tanzil GG, Zwirner J. Sample size considerations in soft tissue biomechanics. Acta Biomater 2023; 169:168-178. [PMID: 37517620 DOI: 10.1016/j.actbio.2023.07.036] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 07/12/2023] [Accepted: 07/23/2023] [Indexed: 08/01/2023]
Abstract
Biomechanical experiments help link tissue morphology with load-deformation characteristics. A tissue-dependent minimum sample number is indispensable to obtain accurate material properties. Stress-strain properties were retrieved from human dura mater and scalp skin, exemplifying two distinct soft tissues. Minimum sample sizes necessary for a stable estimation of material properties were obtained in a simulation study. One-thousand random samples were sequentially drawn for calculating the point at which a majority of the estimators settled within a corridor of stability at given tolerance levels around a 'complete' reference for the mean, median and coefficient of variation. Stable estimations of means and medians can be achieved below sample sizes of 30 at a ± 20%-tolerance within 80%-conformity for scalp skin and dura. Lower tolerance levels or higher conformity dramatically increase the required sample size. Conformity was barely ever reached for the coefficient of variation. The parameter type appears decisive for achieving conformity. STATEMENT OF SIGNIFICANCE: Biomechanical trials utilizing human tissues are needed to obtain material properties for surgical repair, tissue engineering and modeling purposes. Linking tissue mechanics with morphology helps elucidate form-function relationships, the 'morpho-mechanical link'. For material properties to be accurate, it is vital to examine a minimum number of samples. This number may vary between tissues, and the effects of intrinsic tissue characteristics on data accuracy are unclear to date. This study used data obtained from human dura and skin to compute minimum sample sizes required for estimating material properties at a stable level. It was shown that stable estimations are possible at a ± 20%-tolerance within 80%-conformity below sample sizes of 30. Higher accuracy warrants much higher sample sizes for most material properties.
Collapse
Affiliation(s)
- Niels Hammer
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria; Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany; Division of Biomechatronics, Fraunhofer Institute for Machine Tools and Forming Technology Dresden, Germany.
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Andrea Berghold
- Institute for Medical Informatics, Statistics and Documentation, Medical University of Graz, Graz, Austria
| | - Thomas Kuenzer
- Institute for Medical Informatics, Statistics and Documentation, Medical University of Graz, Graz, Austria
| | - Gudrun Pregartner
- Institute for Medical Informatics, Statistics and Documentation, Medical University of Graz, Graz, Austria
| | - Mario Scholze
- Institute of Materials Science and Engineering, Chemnitz University of Technology, Chemnitz, Germany
| | | | - Johann Zwirner
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Department of Oral Sciences, University of Otago, Dunedin, New Zealand
| |
Collapse
|
5
|
Yang S, Hui TL, Wang HQ, Zhang X, Mi YZ, Cheng M, Gao W, Geng CZ, Li SN. High expression of autophagy-related gene EIF4EBP1 could promote tamoxifen resistance and predict poor prognosis in breast cancer. World J Clin Cases 2023; 11:4788-4799. [PMID: 37583983 PMCID: PMC10424051 DOI: 10.12998/wjcc.v11.i20.4788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 04/24/2023] [Accepted: 06/13/2023] [Indexed: 07/06/2023] Open
Abstract
BACKGROUND Breast cancer (BC) remains a public health problem. Tamoxifen (TAM) resistance has caused great difficulties for treatment of BC patients. Eukaryotic translation initiation factor 4E binding protein 1 (EIF4EBP1) plays critical roles in the tumorigenesis and progression of BC. However, the expression and mechanism of EIF4EBP1 in determining the efficacy of TAM therapy in BC patients are still unclear. AIM To investigate the expression and functions of EIF4EBP1 in determining the efficacy of TAM therapy in BC patients. METHODS High-throughput sequencing data of breast tumors were downloaded from the Gene Expression Omnibus database. Differential gene expression analysis identified EIF4EBP1 to be significantly upregulated in cancer tissues. Its prognostic value was analyzed. The biological function and related pathways of EIF4EBP1 was analyzed. Subsequently, the expression of EIF4EBP1 was determined by real-time reverse transcription polymerase chain reaction and western blotting. Cell Counting Kit-8 assays, colony formation assay and wound healing assay were used to understand the phenotypes of function of EIF4EBP1. RESULTS EIF4EBP1 was upregulated in the TAM-resistant cells, and EIF4EBP1 was related to the prognosis of BC patients. Gene Set Enrichment Analysis showed that EIF4EBP1 might be involved in Hedgehog signaling pathways. Decreasing the expression of EIF4EBP1 could reverse TAM resistance, whereas overexpression of EIF4EBP1 promoted TAM resistance. CONCLUSION This study indicated that EIF4EBP1 was overexpressed in the BC and TAM-resistant cell line, which increased cell proliferation, invasion, migration and TAM resistance in BC cells.
Collapse
Affiliation(s)
- Shan Yang
- Department of Breast Center, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, Hebei Province, China
| | - Tian-Li Hui
- Department of Breast Center, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, Hebei Province, China
| | - Hao-Qi Wang
- Department of Breast Center, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, Hebei Province, China
| | - Xi Zhang
- Department of Breast Center, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, Hebei Province, China
| | - Yun-Zhe Mi
- Department of Breast Center, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, Hebei Province, China
| | - Meng Cheng
- Department of Breast Center, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, Hebei Province, China
| | - Wei Gao
- Department of Breast Center, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, Hebei Province, China
| | - Cui-Zhi Geng
- Department of Breast Center, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, Hebei Province, China
| | - Sai-Nan Li
- Department of Breast Center, The Fourth Hospital of Hebei Medical University, Shijiazhuang 050011, Hebei Province, China
| |
Collapse
|
6
|
Zwirner J, Ondruschka B, Scholze M, Thambyah A, Workman J, Hammer N, Niestrawska JA. Dynamic load response of human dura mater at different velocities. J Mech Behav Biomed Mater 2023; 138:105617. [PMID: 36543085 DOI: 10.1016/j.jmbbm.2022.105617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 11/17/2022] [Accepted: 12/06/2022] [Indexed: 12/14/2022]
Abstract
Despite of its assumed role to mitigate brain tissue response under dynamic loading conditions, the human dura mater is frequently neglected in computational and physical human head models. A reason for this is the lack of load-deformation data when the dura mater is loaded dynamically. To date, the biomechanical characterization of the human dura mater predominantly involved quasi-static testing setups. This study aimed to investigate the strain rate-dependent mechanical properties of the human dura mater comparing three different velocities of 0.3, 0.5 and 0.7 m/s. Samples were chosen in a perpendicular orientation to the visible main fiber direction on the samples' surface, which was mostly neglected in previous studies. The elastic modulus of dura mater significantly increased at higher velocities (5.16 [3.38; 7.27] MPa at 0.3 m/s versus 44.38 [35.30; 74.94] MPa at 0.7 m/s). Both the stretch at yield point λf (1.148 [1.137; 1.188] for 0.3 m/s, 1.062 [1.054; 1.066] for 0.5 m/s and 1.015 [1.012; 1.021] for 0.7 m/s) and stress at yield point σf of dura mater (519.14 [366.74; 707.99] kPa for 0.3 m/s versus 300.52 [245.31; 354.89] kPa at 0.7 m/s) significantly decreased with increasing velocities. Conclusively, increasing the load application velocity increases stiffness and decreases tensile strength as well as straining potential of human dura mater between 0.3 and 0.7 m/s. The elastic modulus of human dura mater should be adapted to the respective velocities in computational head impact simulations.
Collapse
Affiliation(s)
- J Zwirner
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Department of Oral Sciences, University of Otago, Dunedin, New Zealand.
| | - B Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - M Scholze
- Institute of Materials Science and Engineering, Chemnitz University of Technology, Chemnitz, Germany
| | - A Thambyah
- Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand
| | - J Workman
- Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand
| | - N Hammer
- Department of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria; Department of Orthopaedic and Trauma Surgery, University of Leipzig, Leipzig, Germany; Fraunhofer IWU, Dresden, Germany
| | - J A Niestrawska
- Department of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria.
| |
Collapse
|
7
|
Cavelier S, Quarrington RD, Jones CF. Tensile properties of human spinal dura mater and pericranium. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2022; 34:4. [PMID: 36586044 PMCID: PMC9805418 DOI: 10.1007/s10856-022-06704-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Accepted: 11/15/2022] [Indexed: 06/17/2023]
Abstract
Autologous pericranium is a promising dural graft material. An optimal graft should exhibit similar mechanical properties to the native dura, but the mechanical properties of human pericranium have not been characterized, and studies of the biomechanical performance of human spinal dura are limited. The primary aim of this study was to measure the tensile structural and material properties of the pericranium, in the longitudinal and circumferential directions, and of the dura in each spinal region (cervical, thoracic and lumbar) and in three directions (longitudinal anterior and posterior, and circumferential). The secondary aim was to determine corresponding constitutive stress-strain equations using a one-term Ogden model. A total of 146 specimens were tested from 7 cadavers. Linear regression models assessed the effect of tissue type, region, and orientation on the structural and material properties. Pericranium was isotropic, while spinal dura was anisotropic with higher stiffness and strength in the longitudinal than the circumferential direction. Pericranium had lower strength and modulus than spinal dura across all regions in the longitudinal direction but was stronger and stiffer than dura in the circumferential direction. Spinal dura and pericranium had similar strain at peak force, toe, and yield, across all regions and directions. Human pericranium exhibits isotropic mechanical behavior that lies between that of the longitudinal and circumferential spinal dura. Further studies are required to determine if pericranium grafts behave like native dura under in vivo loading conditions. The Ogden parameters reported may be used for computational modeling of the central nervous system. Graphical abstract.
Collapse
Affiliation(s)
- Sacha Cavelier
- Adelaide Spinal Research Group, Centre for Orthopaedic & Trauma Research, Adelaide Medical School, The University of Adelaide, Adelaide, SA, 5005, Australia
- Department of Mechanical Engineering, McGill University, Montréal, QC, H3A 0C3, Canada
| | - Ryan D Quarrington
- Adelaide Spinal Research Group, Centre for Orthopaedic & Trauma Research, Adelaide Medical School, The University of Adelaide, Adelaide, SA, 5005, Australia
- School of Mechanical Engineering, The University of Adelaide, Adelaide, SA, 5005, Australia
| | - Claire F Jones
- Adelaide Spinal Research Group, Centre for Orthopaedic & Trauma Research, Adelaide Medical School, The University of Adelaide, Adelaide, SA, 5005, Australia.
- School of Mechanical Engineering, The University of Adelaide, Adelaide, SA, 5005, Australia.
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, SA, 5000, Australia.
| |
Collapse
|
8
|
Qian C, Zheng Y, Xu Z, Zhang Z, Li H, Chen X. Preparation of Cross-Linked Bovine Tendon Acellular Fibers and Study of Their Biophysical and Chemical Properties. J Biomed Nanotechnol 2022. [DOI: 10.1166/jbn.2022.3476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
Abstract
To explore the effect of glutaraldehyde (GA) and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) cross-linking on the biophysical and chemical properties of acellular scaffold to better provide suitable donor materials for tendon reconstruction. GA and EDC with different concentrations
and action time gradients were used to cross-link the acellular scaffold. By detecting the collagen content in the cross-linked scaffold and the cytotoxicity, the cross-linking scheme with minimal damage to the scaffold and minimal cytotoxicity was explored for subsequent studies. The biomechanical
properties (durability, elastic modulus, stressmax) of the scaffolds in GA, EDC, acellular scaffold, and tendon groups were compared, and the scaffold rat models were constructed to further evaluate their in vivo histocompatibility. Under different concentration gradients,
the collagen content of the scaffolds in the GA and EDC groups had no obvious difference. When 0.5% GA was cross-linked for 24 h, and the mass ratio of EDC (1:2) was cross-linked for 4 h, the inhibition rate of the scaffold extract on fibroblasts was the lowest. In the mechanical property
test, the Stressmax, durability, and elastic modulus of the cross-linked acellular scaffolds were significantly improved than those before cross-linking, and the elastic modulus of the EDC acellular scaffold was similar to that of the bovine tendon. In the compatibility test, compared
with the acellular scaffold group, fibroblast activity in the GA group decreased obviously, and the scaffold implanted in rat models led to a persistent chronic inflammatory reaction. However, cells in the EDC group could maintain good activity. Moreover, the scaffold had good compatibility
with rats and did not cause an obvious inflammatory reaction. EDC cross-linking scheme will not damage the acellular scaffold, and the cytotoxicity of the obtained scaffold is controllable. Additionally, EDC cross-linked acellular scaffold has mechanical properties similar to normal tendons
and excellent histocompatibility.
Collapse
|
9
|
Steel S, Pearcy Q, Li K, Scholze M, Zwirner J. The relationship between the pH value of a hydration solution and the biomechanical properties of Crosado-embalmed human iliotibial bands. J Mech Behav Biomed Mater 2022; 132:105266. [DOI: 10.1016/j.jmbbm.2022.105266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 04/27/2022] [Accepted: 05/03/2022] [Indexed: 11/16/2022]
|
10
|
Pearcy Q, Tomlinson J, Niestrawska JA, Möbius D, Zhang M, Zwirner J. Systematic review and meta-analysis of the biomechanical properties of the human dura mater applicable in computational human head models. Biomech Model Mechanobiol 2022; 21:755-770. [PMID: 35266061 PMCID: PMC9132839 DOI: 10.1007/s10237-022-01566-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2021] [Accepted: 02/13/2022] [Indexed: 11/28/2022]
Abstract
Accurate biomechanical properties of the human dura mater are required for computational models and to fabricate artificial substitutes for transplantation and surgical training purposes. Here, a systematic literature review was performed to summarize the biomechanical properties of the human dura mater that are reported in the literature. Furthermore, anthropometric data, information regarding the mechanically tested samples, and specifications with respect to the used mechanical testing setup were extracted. A meta-analysis was performed to obtain the pooled mean estimate for the elastic modulus, ultimate tensile strength, and strain at maximum force. A total of 17 studies were deemed eligible, which focused on human cranial and spinal dura mater in 13 and 4 cases, respectively. Pooled mean estimates for the elastic modulus (n = 448), the ultimate tensile strength (n = 448), and the strain at maximum force (n = 431) of 68.1 MPa, 7.3 MPa and 14.4% were observed for native cranial dura mater. Gaps in the literature related to the extracted data were identified and future directions for mechanical characterizations of human dura mater were formulated. The main conclusion is that the most commonly used elastic modulus value of 31.5 MPa for the simulation of the human cranial dura mater in computational head models is likely an underestimation and an oversimplification given the morphological diversity of the tissue in different brain regions. Based on the here provided meta-analysis, a stiffer linear elastic modulus of 68 MPa was observed instead. However, further experimental data are essential to confirm its validity.
Collapse
Affiliation(s)
- Quinton Pearcy
- Department of Anatomy, University of Otago, Dunedin, New Zealand
| | - Joanna Tomlinson
- Department of Anatomy, University of Otago, Dunedin, New Zealand
| | - Justyna A Niestrawska
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria
| | - Dustin Möbius
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Ming Zhang
- Department of Anatomy, University of Otago, Dunedin, New Zealand
| | - Johann Zwirner
- Department of Anatomy, University of Otago, Dunedin, New Zealand. .,Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. .,Institute of Legal Medicine, University of Leipzig, Leipzig, Germany.
| |
Collapse
|
11
|
Cavelier S, Quarrington RD, Jones CF. Mechanical properties of porcine spinal dura mater and pericranium. J Mech Behav Biomed Mater 2021; 126:105056. [PMID: 34953436 DOI: 10.1016/j.jmbbm.2021.105056] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 11/22/2021] [Accepted: 11/24/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND The objective of this study was to characterize and compare the mechanical properties of porcine pericranium and spinal dura mater, to evaluate the mechanical suitability of pericranium as a dural graft. METHOD Eighty-eight spinal dura (cervical, thoracic, and lumbar regions, in ventral longitudinal, dorsal longitudinal and circumferential orientations) and eighteen pericranium samples (ventral-dorsal, and lateral orientations) from four pigs, were harvested and subjected to uniaxial loading while hydrated. The stiffness, strain at toe-linear regions transition, strain at linear-yield regions transition and other structural and mechanical properties were measured. Stress-strain curves were fitted to a one-term Ogden model and Ogden parameters were calculated. Linear regression models with cluster-robust standard errors were used to assess the effect of region and orientation on material and structural properties. RESULTS Both spinal dura and pericranium exhibited distinct anisotropy and were stiffer in the longitudinal direction. The tissues exhibited structural and mechanical similarities especially in terms of stiffness and strains in the linear region. Stiffness ranged from 1.28 to 5.32 N/mm for spinal dura and 2.42-3.90 N/mm for pericranium. In the circumferential and longitudinal directions, the stiffness of spinal dura specimens was statistically similar to that of pericranium in the same orientation. The strain at the upper bound of the linear region of longitudinal pericranium (28.0%) was statistically similar to that of any spinal dura specimens (24.4-32.9%). CONCLUSIONS Autologous pericranium has advantageous physical properties for spinal duraplasty. The present study demonstrated that longitudinally oriented pericranium is mechanically compatible with spinal duraplasty procedures. Autologous pericranium grafts will likely support the mechanical loads transmitted from the spinal dura, but further biomechanical analyses are required to study the effect of the lower yield strain of circumferential pericranium compared to spinal dura. Finally, the Ogden parameters calculated for pericranium, and the spinal dura at each spinal level, will be useful for computational models incorporating these soft tissues.
Collapse
Affiliation(s)
- S Cavelier
- Spinal Research Group & Centre for Orthopaedic and Trauma Research, Adelaide Medical School, The University of Adelaide, Adelaide, SA, 5005, Australia; Department of Mechanical Engineering, McGill University, 817 Rue Sherbrooke Ouest, Montréal, QC, H3A 0C3, Canada
| | - R D Quarrington
- Spinal Research Group & Centre for Orthopaedic and Trauma Research, Adelaide Medical School, The University of Adelaide, Adelaide, SA, 5005, Australia
| | - C F Jones
- Spinal Research Group & Centre for Orthopaedic and Trauma Research, Adelaide Medical School, The University of Adelaide, Adelaide, SA, 5005, Australia; School of Mechanical Engineering, The University of Adelaide, Adelaide, SA, 5005, Australia.
| |
Collapse
|
12
|
Zwirner J, Ondruschka B, Pregartner G, Berghold A, Scholze M, Hammer N. On the correlations of biomechanical properties of super-imposed temporal tissue layers and their age-, sex-, side- and post-mortem interval dependence. J Biomech 2021; 130:110847. [PMID: 34753030 DOI: 10.1016/j.jbiomech.2021.110847] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 10/25/2021] [Accepted: 10/25/2021] [Indexed: 10/20/2022]
Abstract
Obtaining biomechanical properties of biological tissues for simulation purposes or graft developments is time and resource consuming. The number of samples required for biomechanical tests could be reduced if the load-deformation properties of a given tissue layer could be estimated from adjacent layers or if the biomechanical parameters were unaffected by age, bodyside, sex or post-mortem interval. This study investigates for the first time potential correlations of multiple super-imposed tissue layers using the temporal region of the human head as an area of broad interest in biomechanical modelling. Spearman correlations between biomechanical properties of the scalp, muscle fascia, muscle, bone and dura mater from up to 83 chemically unfixed cadavers were investigated. The association with age, sex and post-mortem interval was assessed. The results revealed sporadic correlations between the corresponding layers, such as the maximum force (r = 0.43) and ultimate tensile strength (r = 0.33) between scalp and muscle. Side- and age-dependence of the biomechanical properties were different between the tissue types. Strain at maximum force of fascia (r = -0.37) and elastic modulus of temporal muscle (r = 0.26) weakly correlated with post-mortem interval. Only strain at maximum force of scalp differed significantly between sexes. Uniaxial biomechanical properties of individual head tissue layers can thus not be estimated solely based on adjacent layers. Therefore, correlations between the tissues' biomechanical properties, anthropometric data and post-mortem interval need to be established independently for each layer. Sex seems not to be a relevant influencing factor for the passive tissue mechanics of the here investigated temporal head tissue layers.
Collapse
Affiliation(s)
- J Zwirner
- Department of Anatomy, University of Otago, Dunedin, New Zealand; Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Institute of Legal Medicine, University of Leipzig, Leipzig, Germany.
| | - B Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - G Pregartner
- Institute for Medical Informatics, Statistics and Documentation, Medical University of Graz, Graz, Austria
| | - A Berghold
- Institute for Medical Informatics, Statistics and Documentation, Medical University of Graz, Graz, Austria
| | - M Scholze
- Institute of Materials Science and Engineering, Chemnitz University of Technology, Chemnitz, Germany; Institute of Macroscopic and Clinical Anatomy, Medical University of Graz, Graz, Austria
| | - N Hammer
- Institute of Macroscopic and Clinical Anatomy, Medical University of Graz, Graz, Austria; Department of Orthopedic and Trauma Surgery, University of Leipzig, Germany; Fraunhofer IWU, Dresden, Germany.
| |
Collapse
|
13
|
Mechanical characterisation of the human dura mater, falx cerebri and superior sagittal sinus. Acta Biomater 2021; 134:388-400. [PMID: 34314888 DOI: 10.1016/j.actbio.2021.07.043] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 07/01/2021] [Accepted: 07/21/2021] [Indexed: 01/14/2023]
Abstract
The cranial meninges have been shown to play a pivotal role in traumatic brain injury mechanopathology. However, while the mechanical response of the brain and its many subregions have been studied extensively, the meninges have conventionally been overlooked. This paper presents the first comparative mechanical analysis of human dura mater, falx cerebri and superior sagittal sinus tissues. Biaxial tensile analysis identified that these tissues are mechanically heterogeneous, in contrast to the assumption that the tissues are mechanically homogeneous which is typically employed in FE model design. A thickness of 0.91 ± 0.05 (standard error) mm for the falx cerebri was also identified. This data can aid in improving the biofidelity of the influential falx structure in FE models. Additionally, the use of a collagen hybridizing peptide on the superior sagittal sinus suggests this structure is particularly susceptible to the effects of circumferential stretch, which may have important implications for clinical treatment of dural venous sinus pathologies. Collectively, this research progresses understanding of meningeal mechanical and structural characteristics and may aid in elucidating the behaviour of these tissues in healthy and diseased conditions. STATEMENT OF SIGNIFICANCE: This study presents the first evaluation of human falx cerebri and superior sagittal sinus mechanical, geometrical and structural properties, along with a comparison to cranial dura mater. To mechanically characterise the tissues, biaxial tensile testing is conducted on the tissues. This analysis identifies, for the first time, mechanical stiffness differences between these tissues. Additionally, geometrical analysis identifies that there are thickness differences between the tissues. The evaluation of human meningeal tissues allows for direct implementation of the novel data to finite element head injury models to enable improved biofidelity of these influential structures in traumatic brain injury simulations. This work also identifies that the superior sagittal sinus may be easily damaged during clinical angioplasty procedures, which may inform the treatment of dural sinus pathologies.
Collapse
|
14
|
Biomechanics of vascular areas of the human cranial dura mater. J Mech Behav Biomed Mater 2021; 125:104866. [PMID: 34655943 DOI: 10.1016/j.jmbbm.2021.104866] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/07/2021] [Accepted: 09/26/2021] [Indexed: 11/21/2022]
Abstract
Accurate biomechanical properties of the human cranial dura mater are paramount for computational head models, artificial graft developments and biomechanical basic research. Yet, it is unclear whether areas of the dura containing meningeal vessels biomechanically differ from avascular areas. Here, 244 dura mater samples with or without vessels from 32 cadavers were tested in a quasi-static uniaxial tensile testing setup. The thicknesses of the meningeal and periosteal dura in vascular and avascular areas were histologically investigated in 36 samples using van Gieson staining. The elastic modulus of 112 MPa from dura samples containing vessels running transversely was significantly lower than samples with vessels running longitudinally (151 MPa; p < 0.001). The ultimate tensile strength of dura samples with transversely running vessels (11.1 MPa) was significantly lower in comparison to both avascular samples (14.9 MPa; p < 0.001) and samples with a longitudinally running vessel (15.0 MPa; p < 0.001). The maximum force of dura samples with longitudinally running vessels was 37 N (p < 0.001), this was significantly higher compared to the other groups which were 23 N (p < 0.001). The meningeal and periosteal dura layer thicknesses were not statistically different in avascular areas (p > 0.222). However, around the vessels, the meningeal dura layer was significantly thicker compared to the periosteal layer (p ≤ 0.019). The sum of the meningeal and periosteal layers was similar between vascular and avascular areas (p ≥ 0.071). Vascular areas of the human cranial dura mater withstand the same forces as avascular areas when being stretched. When stretched along the vessel, the dura-vessel composite can withstand even higher tensile forces compared to avascular areas. Vascular areas of the cranial dura mater seem to be similar when compared to avascular areas making their separate simulation in computational models non-essential.
Collapse
|
15
|
Zwirner J, Ondruschka B, Scholze M, Workman J, Thambyah A, Hammer N. The dynamic impact behavior of the human neurocranium. Sci Rep 2021; 11:11331. [PMID: 34059728 PMCID: PMC8167104 DOI: 10.1038/s41598-021-90322-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Accepted: 01/21/2021] [Indexed: 11/16/2022] Open
Abstract
Realistic biomechanical models of the human head should accurately reflect the mechanical properties of all neurocranial bones. Previous studies predominantly focused on static testing setups, males, restricted age ranges and scarcely investigated the temporal area. This given study determined the biomechanical properties of 64 human neurocranial samples (age range of 3 weeks to 94 years) using testing velocities of 2.5, 3.0 and 3.5 m/s in a three-point bending setup. Maximum forces were higher with increasing testing velocities (p ≤ 0.031) but bending strengths only revealed insignificant increases (p ≥ 0.052). The maximum force positively correlated with the sample thickness (p ≤ 0.012 at 2.0 m/s and 3.0 m/s) and bending strength negatively correlated with both age (p ≤ 0.041) and sample thickness (p ≤ 0.036). All parameters were independent of sex (p ≥ 0.120) apart from a higher bending strength of females (p = 0.040) for the 3.5 -m/s group. All parameters were independent of the post mortem interval (p ≥ 0.061). This study provides novel insights into the dynamic mechanical properties of distinct neurocranial bones over an age range spanning almost one century. It is concluded that the former are age-, site- and thickness-dependent, whereas sex dependence needs further investigation.
Collapse
Affiliation(s)
- Johann Zwirner
- Department of Anatomy, University of Otago, Dunedin, New Zealand. .,Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Institute of Legal Medicine, University of Leipzig, Leipzig, Germany
| | - Mario Scholze
- Institute of Materials Science and Engineering, Chemnitz University of Technology, Chemnitz, Germany.,Institute of Macroscopic and Clinical Anatomy, Medical University of Graz, Graz, Austria
| | - Joshua Workman
- Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand
| | - Ashvin Thambyah
- Department of Chemical and Materials Engineering, University of Auckland, Auckland, New Zealand
| | - Niels Hammer
- Institute of Macroscopic and Clinical Anatomy, Medical University of Graz, Graz, Austria.,Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany.,Fraunhofer IWU, Dresden, Germany
| |
Collapse
|
16
|
Walsh DR, Zhou Z, Li X, Kearns J, Newport DT, Mulvihill JJE. Mechanical Properties of the Cranial Meninges: A Systematic Review. J Neurotrauma 2021; 38:1748-1761. [PMID: 33191848 DOI: 10.1089/neu.2020.7288] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
The meninges are membranous tissues that are pivotal in maintaining homeostasis of the central nervous system. Despite the importance of the cranial meninges in nervous system physiology and in head injury mechanics, our knowledge of the tissues' mechanical behavior and structural composition is limited. This systematic review analyzes the existing literature on the mechanical properties of the meningeal tissues. Publications were identified from a search of Scopus, Academic Search Complete, and Web of Science and screened for eligibility according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The review details the wide range of testing techniques employed to date and the significant variability in the observed experimental findings. Our findings identify many gaps in the current literature that can serve as a guide for future work for meningeal mechanics investigators. The review identifies no peer-reviewed mechanical data on the falx and tentorium tissues, both of which have been identified as key structures in influencing brain injury mechanics. A dearth of mechanical data for the pia-arachnoid complex also was identified (no experimental mechanics studies on the human pia-arachnoid complex were identified), which is desirable for biofidelic modeling of human head injuries. Finally, this review provides recommendations on how experiments can be conducted to allow for standardization of test methodologies, enabling simplified comparisons and conclusions on meningeal mechanics.
Collapse
Affiliation(s)
- Darragh R Walsh
- Bernal Institute, University of Limerick, Limerick, Ireland.,School of Engineering, University of Limerick, Limerick, Ireland
| | - Zhou Zhou
- Division of Neuronic Engineering, KTH Royal Institute of Technology, Huddinge, Sweden
| | - Xiaogai Li
- Division of Neuronic Engineering, KTH Royal Institute of Technology, Huddinge, Sweden
| | - Jamie Kearns
- Munster Rugby High Performance Center, University of Limerick, Limerick, Ireland
| | - David T Newport
- Bernal Institute, University of Limerick, Limerick, Ireland.,School of Engineering, University of Limerick, Limerick, Ireland
| | - John J E Mulvihill
- Bernal Institute, University of Limerick, Limerick, Ireland.,School of Engineering, University of Limerick, Limerick, Ireland.,Health Research Institute, University of Limerick, Limerick, Ireland
| |
Collapse
|
17
|
Walsh DR, Lynch JJ, O' Connor DT, Newport DT, Mulvihill JJE. Mechanical and structural characterisation of the dural venous sinuses. Sci Rep 2020; 10:21763. [PMID: 33303894 PMCID: PMC7729903 DOI: 10.1038/s41598-020-78694-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 11/26/2020] [Indexed: 12/27/2022] Open
Abstract
The dural venous sinuses play an integral role in draining venous blood from the cranial cavity. As a result of the sinuses anatomical location, they are of significant importance when evaluating the mechanopathology of traumatic brain injury (TBI). Despite the importance of the dural venous sinuses in normal neurophysiology, no mechanical analyses have been conducted on the tissues. In this study, we conduct mechanical and structural analysis on porcine dural venous sinus tissue to help elucidate the tissues’ function in healthy and diseased conditions. With longitudinal elastic moduli values ranging from 33 to 58 MPa, we demonstrate that the sinuses exhibit higher mechanical stiffness than that of native dural tissue, which may be of interest to the field of TBI modelling. Furthermore, by employing histological staining and a colour deconvolution protocol, we show that the sinuses have a collagen-dominant extracellular matrix, with collagen area fractions ranging from 84 to 94%, which likely explains the tissue’s large mechanical stiffness. In summary, we provide the first investigation of the dural venous sinus mechanical behaviour with accompanying structural analysis, which may aid in understanding TBI mechanopathology.
Collapse
Affiliation(s)
- Darragh R Walsh
- Bernal Institute, University of Limerick, Limerick, Ireland.,School of Engineering, University of Limerick, Limerick, Ireland
| | - James J Lynch
- Bernal Institute, University of Limerick, Limerick, Ireland.,School of Engineering, University of Limerick, Limerick, Ireland
| | - David T O' Connor
- Bernal Institute, University of Limerick, Limerick, Ireland.,School of Engineering, University of Limerick, Limerick, Ireland.,Health Research Institute, University of Limerick, Limerick, Ireland
| | - David T Newport
- Bernal Institute, University of Limerick, Limerick, Ireland.,School of Engineering, University of Limerick, Limerick, Ireland
| | - John J E Mulvihill
- Bernal Institute, University of Limerick, Limerick, Ireland. .,School of Engineering, University of Limerick, Limerick, Ireland. .,Health Research Institute, University of Limerick, Limerick, Ireland.
| |
Collapse
|
18
|
Zwirner J, Koutp A, Vidakovic H, Ondruschka B, Kieser DC, Hammer N. Assessment of plantaris and peroneus tertius tendons as graft materials for ankle ligament reconstructions - A cadaveric biomechanical study. J Mech Behav Biomed Mater 2020; 115:104244. [PMID: 33310268 DOI: 10.1016/j.jmbbm.2020.104244] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/14/2020] [Accepted: 11/28/2020] [Indexed: 12/26/2022]
Abstract
Both the plantaris tendon and the peroneus tertius tendon are used as auto- and allogenous graft materials to reconstruct the ankle ligament complex. However, it is unclear to what extent these graft materials resemble the load-deformation behavior of the ankle ligaments. A total of 34 human ankle ligaments and 35 tendons were assessed mechanically deploying a quasi-static tensile testing setup. Tendons were significantly stiffer (median elastic moduli: plantaris tendon = 465.7 MPa, peroneus tertius tendon = 338.5 MPa, medial ligament = 61.4 MPa, lateral ligament = 49.3 MPa; p ≤ 0.035), but more distensible (median strain at maximum force: plantaris tendon = 15.1%, peroneus tertius tendon = 15.3%, medial ligament = 9.3%, lateral ligament = 9.6%; p ≤ 0.008) and mechanically tougher (median ultimate tensile strength: plantaris tendon = 51.0 MPa, peroneus tertius tendon = 40.5 MPa, medial ligament = 4.1 MPa, lateral ligament = 3.5 MPa; p ≤ 0.033) when compared to medial and lateral ankle ligaments. The lateral ligaments of the right ankle were significantly tougher compared to the left side (p = 0.015). The elastic modulus of the medial ligament (r = 0.489, p = 0.045) and the peroneus tertius tendon (r = 0.517, p = 0.014) yielded an age-dependent increase. Both tendons seem biomechanically suitable graft materials to replace the medial and lateral ankle ligaments during physiological loading. The age-dependent increase in tissue elastic properties of the medial vs. lateral ankle ligaments, and differences in ultimate tensile strength between the lateral ligaments left vs. right, may reflect the complex asymmetric loading behavior of both ankle ligaments.
Collapse
Affiliation(s)
- J Zwirner
- Department of Anatomy, University of Otago, Dunedin, New Zealand.
| | - A Koutp
- Institute of Macroscopic and Clinical Anatomy, Medical University of Graz, Graz, Austria
| | - H Vidakovic
- Department of Orthopedics and Musculoskeletal Medicine, University of Otago, Christchurch, New Zealand
| | - B Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - D C Kieser
- Department of Orthopedics and Musculoskeletal Medicine, University of Otago, Christchurch, New Zealand
| | - N Hammer
- Institute of Macroscopic and Clinical Anatomy, Medical University of Graz, Graz, Austria; Department of Orthopedic and Trauma Surgery, University of Leipzig, Germany; Fraunhofer IWU, Dresden, Germany
| |
Collapse
|
19
|
Zwirner J, Ondruschka B, Scholze M, Hammer N. Surface coating and speckling of the human iliotibial tract does not affect its load-deformation properties. Sci Rep 2020; 10:20747. [PMID: 33247150 PMCID: PMC7695729 DOI: 10.1038/s41598-020-77299-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 10/29/2020] [Indexed: 01/23/2023] Open
Abstract
Stochastic surface patterns form an important requirement to facilitate digital image correlation and to subsequently quantify material properties of various tissues when loaded and deformed without artefacts arising from material slippage. Depending on the samples' natural colour, a surface pattern is created by speckling with colour or dye only, or it requires combined surface coating and speckling before to enhance the contrast, to facilitate high-quality data recording for mechanical evaluation. However, it is unclear to date if the colours deployed for coating and speckling do significantly alter the biomechanical properties of soft tissues. The given study investigated the biomechanical properties of 168 human iliotibial tract samples as a model for collagen-rich soft tissues, separated into four groups: untreated, graphite speckling only, water-based coating plus graphite speckling and solvent-based coating plus graphite speckling following a standardized approach of application and data acquisition. The results reveal that elastic modulus, ultimate tensile strength and strain at maximum force of all groups were similar and statistically non-different (p ≥ 0.69). Qualitatively, the speckle patterns revealed increasing contrast differences in the following order: untreated, graphite speckling only, water-based coating plus graphite speckling and solvent-based coating plus graphite speckling. Conclusively, both coating by water- and solvent-based paints, as well as exclusive graphite speckling, did not significantly influence the load-deformation parameters of the here used human iliotibial tract as a model for collagen-rich soft tissues. In consequence, water- and solvent-based coating paints seem equally suitable to coat collagen-rich soft tissues for digital image correlation, resulting in suitable speckle patterns and unbiased data acquisition.
Collapse
Affiliation(s)
- Johann Zwirner
- Department of Anatomy, University of Otago, Dunedin, New Zealand.
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- Institute of Legal Medicine, University of Leipzig, Leipzig, Germany
| | - Mario Scholze
- Institute of Materials Science and Engineering, Chemnitz University of Technology, Chemnitz, Germany
- Department of Macroscopic and Clinical Anatomy, Medical University of Graz, Graz, Austria
| | - Niels Hammer
- Department of Macroscopic and Clinical Anatomy, Medical University of Graz, Graz, Austria.
- Department of Orthopaedic and Trauma Surgery, University of Leipzig, Leipzig, Germany.
- Fraunhofer IWU, Dresden, Germany.
| |
Collapse
|
20
|
Load-deformation characteristics of acellular human scalp: assessing tissue grafts from a material testing perspective. Sci Rep 2020; 10:19243. [PMID: 33159106 PMCID: PMC7648071 DOI: 10.1038/s41598-020-75875-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Accepted: 10/05/2020] [Indexed: 11/13/2022] Open
Abstract
Acellular matrices seem promising scaffold materials for soft tissue regeneration. Biomechanical properties of such scaffolds were shown to be closely linked to tissue regeneration and cellular ingrowth. This given study investigated uniaxial load-deformation properties of 34 human acellular scalp samples and compared these to age-matched native tissues as well as acellular dura mater and acellular temporal muscle fascia. As previously observed for human acellular dura mater and temporal muscle fascia, elastic modulus (p = 0.13) and ultimate tensile strength (p = 0.80) of human scalp samples were unaffected by the cell removal. Acellular scalp samples showed a higher strain at maximum force compared to native counterparts (p = 0.02). The direct comparison of acellular scalp to acellular dura mater and temporal muscle fascia revealed a higher elasticity (p < 0.01) and strain at maximum force (p = 0.02), but similar ultimate tensile strength (p = 0.47). Elastic modulus and ultimate tensile strength of acellular scalp decreased with increasing post-mortem interval. The elongation behavior formed the main biomechanical difference between native and acellular human scalp samples with elastic modulus and ultimate tensile strength being similar when comparing the two.
Collapse
|
21
|
Zwirner J, Scholze M, Ondruschka B, Hammer N. What is Considered a Variation of Biomechanical Parameters in Tensile Tests of Collagen-Rich Human Soft Tissues? - Critical Considerations Using the Human Cranial Dura Mater as a Representative Morpho-Mechanic Model. MEDICINA (KAUNAS, LITHUANIA) 2020; 56:E520. [PMID: 33027931 PMCID: PMC7600870 DOI: 10.3390/medicina56100520] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 09/27/2020] [Accepted: 09/28/2020] [Indexed: 12/23/2022]
Abstract
Background and Objectives: Profound knowledge on the load-dependent behavior of human soft tissues is required for the development of suitable replacements as well as for realistic computer simulations. Regarding the former, e.g., the anisotropy of a particular biological tissue has to be represented with site- and direction-dependent particular mechanical values. Contrary to this concept of consistent mechanical properties of a defined soft tissue, mechanical parameters of soft tissues scatter considerably when being determined in tensile tests. In spite of numerous measures taken to standardize the mechanical testing of soft tissues, several setup- and tissue-related factors remain to influence the mechanical parameters of human soft tissues to a yet unknown extent. It is to date unclear if measurement extremes should be considered a variation or whether these data have to be deemed incorrect measurement outliers. This given study aimed to determine mechanical parameters of the human cranial dura mater as a model for human soft tissues using a highly standardized protocol and based on this, critically evaluate the definition for the term mechanical "variation" of human soft tissue. Materials and Methods: A total of 124 human dura mater samples with an age range of 3 weeks to 94 years were uniformly retrieved, osmotically adapted and mechanically tested using customized 3D-printed equipment in a quasi-static tensile testing setup. Scanning electron microscopy of 14 samples was conducted to relate the mechanical parameters to morphological features of the dura mater. Results: The here obtained mechanical parameters were scattered (elastic modulus = 46.06 MPa, interquartile range = 33.78 MPa; ultimate tensile strength = 5.56 MPa, interquartile range = 4.09 MPa; strain at maximum force = 16.58%, interquartile range = 4.81%). Scanning electron microscopy revealed a multi-layered nature of the dura mater with varying fiber directions between its outer and inner surface. Conclusions: It is concluded that mechanical parameters of soft tissues such as human dura mater are highly variable even if a highly standardized testing setup is involved. The tissue structure and composition appeared to be the main contributor to the scatter of the mechanical parameters. In consequence, mechanical variation of soft tissues can be defined as the extremes of a biomechanical parameter due to an uncontrollable change in tissue structure and/or the respective testing setup.
Collapse
Affiliation(s)
- Johann Zwirner
- Department of Anatomy, University of Otago, Dunedin 9016, New Zealand
| | - Mario Scholze
- Institute of Materials Science and Engineering, Chemnitz University of Technology, 09125 Chemnitz, Germany;
- Department of Macroscopic and Clinical Anatomy, Medical University of Graz, 8010 Graz, Austria
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, 22529 Hamburg, Germany;
| | - Niels Hammer
- Department of Macroscopic and Clinical Anatomy, Medical University of Graz, 8010 Graz, Austria
- Department of Orthopaedic and Trauma Surgery, University of Leipzig, 04103 Leipzig, Germany
- Fraunhofer IWU, 01187 Dresden, Germany
| |
Collapse
|
22
|
Scholze M, Safavi S, Li KC, Ondruschka B, Werner M, Zwirner J, Hammer N. Standardized tensile testing of soft tissue using a 3D printed clamping system. HARDWAREX 2020; 8:e00159. [PMID: 35498242 PMCID: PMC9041186 DOI: 10.1016/j.ohx.2020.e00159] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 11/03/2020] [Accepted: 11/16/2020] [Indexed: 06/14/2023]
Abstract
Biomechanical testing of soft tissues forms the backbone in the experimental validation of tissue engineering and for modelling purposes. The standardized testing of soft tissues requires different experimental protocols and fixtures compared to hard tissues or non-biological materials due to their characteristics. Some of the most commonly-used clamping methods for soft tissue testing affect the tissues' mechanical properties as chemicals are involved to decelerate degradation and autolysis. Moreover, they are unsuitable for standardized and high-throughput testing. Material slippage is also a recurrent unwanted influence on the testing routine with impact on measurement validity. Addressing these issues, this protocol presents a clamping system for simplified testing of biological soft tissues with all necessary components manufactured utilizing 3D printing technology. Templates allow trimming the samples into standardized shapes and sizes while preparation tables facilitate clamping in a fixed distance. The key parts of the system are clamps with a pyramid design, which allow the mounting of biological soft tissues before transferring it into the testing device and minimize material slippage during tensile testing. Flexible holder arms are used to transfer samples from preparation tables into the testing device and simplify positioning. Mechanical testing itself is performed with digital image correlation for precise strain measurements.
Collapse
Affiliation(s)
- Mario Scholze
- Institute of Materials Science and Engineering, Chemnitz University of Technology, Chemnitz, Germany
- Department of Clinical and Macroscopic Anatomy, Medical University of Graz, Graz, Austria
| | - Sarah Safavi
- Department of Anatomy, University of Otago, Dunedin, New Zealand
| | - Kai Chun Li
- Department of Oral Rehabilitation, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael Werner
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, Dresden, Germany
- Institute of Anatomy, University of Leipzig, Leipzig, Germany
| | - Johann Zwirner
- Department of Anatomy, University of Otago, Dunedin, New Zealand
| | - Niels Hammer
- Department of Clinical and Macroscopic Anatomy, Medical University of Graz, Graz, Austria
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, Dresden, Germany
- Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany
| |
Collapse
|
23
|
Zwirner J, Ondruschka B, Scholze M, Schulze-Tanzil G, Hammer N. Mechanical properties of native and acellular temporal muscle fascia for surgical reconstruction and computational modelling purposes. J Mech Behav Biomed Mater 2020; 108:103833. [DOI: 10.1016/j.jmbbm.2020.103833] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 04/20/2020] [Accepted: 04/24/2020] [Indexed: 01/12/2023]
|
24
|
Chuan D, Wang Y, Fan R, Zhou L, Chen H, Xu J, Guo G. Fabrication and Properties of a Biomimetic Dura Matter Substitute Based on Stereocomplex Poly(Lactic Acid) Nanofibers . Int J Nanomedicine 2020; 15:3729-3740. [PMID: 32547025 PMCID: PMC7266401 DOI: 10.2147/ijn.s248998] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Background Duraplasty is one of the most critical issues in neurosurgical procedures because the defect of dura matter will cause many complications. Electrospinning can mimic the 3D structure of the natural extracellular matrix whose structure is similar to that of dura matter. Poly(L-lactic acid) (PLLA) has been used to fabricate dura matter substitutes and showed compatibility to dural tissue. However, the mechanical properties of the PLLA substitute cannot match the mechanical properties of the human dura mater. Methods and Results We prepared stereocomplex nanofiber membranes based on enantiomeric poly(lactic acid) and poly(D-lactic acid)-grafted tetracalcium phosphate via electrospinning. X-ray diffraction results showed the formation of stereocomplex crystallites (SC) in the composite nanofiber membranes. Scanning electron microscope observation images showed that composites nanofibers with higher SC formation can keep its original morphologies after heat treatment, suggesting the heat resistance of composite nanofiber membranes. Differential scanning calorimeter tests confirmed that the melting temperature of composite nanofiber membranes was approximately 222°C, higher than that of PLLA. Tensile testing indicated that the ultimate tensile strength and the elongation break of the stereocomplex nanofiber membranes were close to human dura matter. In vitro cytotoxicity studies proved that the stereocomplex nanofiber membranes were non-toxic. The neuron-like differentiation of marrow stem cells on the stereocomplex nanofiber membranes indicated its neuron compatibility. Conclusion The stereocomplex nanofiber membranes have the potential to serve as a dura mater substitute.
Collapse
Affiliation(s)
- Di Chuan
- State Key Laboratory of Biotherapy and Cancer Center and Department of Neurosurgery, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu610041, People’s Republic of China
| | - Yuelong Wang
- State Key Laboratory of Biotherapy and Cancer Center and Department of Neurosurgery, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu610041, People’s Republic of China
| | - Rangrang Fan
- State Key Laboratory of Biotherapy and Cancer Center and Department of Neurosurgery, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu610041, People’s Republic of China
| | - Liangxue Zhou
- State Key Laboratory of Biotherapy and Cancer Center and Department of Neurosurgery, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu610041, People’s Republic of China
| | - Haifeng Chen
- State Key Laboratory of Biotherapy and Cancer Center and Department of Neurosurgery, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu610041, People’s Republic of China
| | - Jianguo Xu
- State Key Laboratory of Biotherapy and Cancer Center and Department of Neurosurgery, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu610041, People’s Republic of China
| | - Gang Guo
- State Key Laboratory of Biotherapy and Cancer Center and Department of Neurosurgery, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu610041, People’s Republic of China
- Correspondence: Gang Guo; Liangxue Zhou State Key Laboratory of Biotherapy and Cancer Center, and Department of Neurosurgery, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, No. 17, Block 3, Southern Renmin Road, Chengdu610041, People’s Republic of ChinaTel +86 28-8516 4063Fax +86 28 85164060 Email ;
| |
Collapse
|
25
|
Yang X, Chen S, Liu X, Yu M, Liu X. Drug Delivery Based on Nanotechnology for Target Bone Disease. Curr Drug Deliv 2020; 16:782-792. [PMID: 31530265 DOI: 10.2174/1567201816666190917123948] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Revised: 09/03/2019] [Accepted: 09/16/2019] [Indexed: 02/07/2023]
Abstract
Bone diseases are a serious problem in modern human life. With the coming acceleration of global population ageing, this problem will become more and more serious. Due to the specific physiological characteristics and local microenvironment of bone tissue, it is difficult to deliver drugs to the lesion site. Therefore, the traditional orthopedic medicine scheme has the disadvantages of high drug frequency, large dose and relatively strong side effects. How to target deliver drugs to the bone tissue or even target cells is the focus of the development of new drugs. Nano drug delivery system with a targeting group can realize precise delivery of orthopedic drugs and effectively reduce the systemic toxicity. In addition, the application of bone tissue engineering scaffolds and biomedical materials to realize in situ drug delivery also are research hotspot. In this article, we briefly review the application of nanotechnology in targeted therapies for bone diseases.
Collapse
Affiliation(s)
- Xiaosong Yang
- Orthopedic Department, Peking University Third Hospital, Beijing 100191, China
| | - Shizhu Chen
- Laboratory for Biological Effects of Nanomaterials and Nanosafety, National Center for Nanoscience and Technology, Beijing 100190, China
| | - Xiao Liu
- Orthopedic Department, Peking University Third Hospital, Beijing 100191, China
| | - Miao Yu
- Orthopedic Department, Peking University Third Hospital, Beijing 100191, China
| | - Xiaoguang Liu
- Orthopedic Department, Peking University Third Hospital, Beijing 100191, China
| |
Collapse
|
26
|
Jahangirian H, Azizi S, Rafiee-Moghaddam R, Baratvand B, Webster TJ. Status of Plant Protein-Based Green Scaffolds for Regenerative Medicine Applications. Biomolecules 2019; 9:E619. [PMID: 31627453 PMCID: PMC6843632 DOI: 10.3390/biom9100619] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 10/09/2019] [Accepted: 10/14/2019] [Indexed: 12/20/2022] Open
Abstract
In recent decades, regenerative medicine has merited substantial attention from scientific and research communities. One of the essential requirements for this new strategy in medicine is the production of biocompatible and biodegradable scaffolds with desirable geometric structures and mechanical properties. Despite such promise, it appears that regenerative medicine is the last field to embrace green, or environmentally-friendly, processes, as many traditional tissue engineering materials employ toxic solvents and polymers that are clearly not environmentally friendly. Scaffolds fabricated from plant proteins (for example, zein, soy protein, and wheat gluten), possess proper mechanical properties, remarkable biocompatibility and aqueous stability which make them appropriate green biomaterials for regenerative medicine applications. The use of plant-derived proteins in regenerative medicine has been especially inspired by green medicine, which is the use of environmentally friendly materials in medicine. In the current review paper, the literature is reviewed and summarized for the applicability of plant proteins as biopolymer materials for several green regenerative medicine and tissue engineering applications.
Collapse
Affiliation(s)
- Hossein Jahangirian
- Department of Chemical Engineering, College of Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA 02115, USA.
| | - Susan Azizi
- Applied Science and Technology Education Center of Ahvaz Municipality, Ahvaz 617664343, Iran.
| | - Roshanak Rafiee-Moghaddam
- Department of Chemical Engineering, College of Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA 02115, USA.
| | - Bahram Baratvand
- Department of Physiotherapy, Faculty of Health and Sport, Mahsa University, Bandar Saujana Putra, Jenjarum Selangor 42610, Malaysia.
| | - Thomas J Webster
- Department of Chemical Engineering, College of Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA 02115, USA.
| |
Collapse
|