Peixoto RF, Tonin BSH, Pinto-Fiamengui LMS, Freitas-Pontes KM, Regis RR, Mattos MDGCD. Analysis of implant-supported cantilever fixed partial denture: An in vitro comparative study on vertical misfit, stress distribution, and cantilever fracture strength.
J Prosthodont 2024;
33:584-592. [PMID:
37470305 DOI:
10.1111/jopr.13739]
[Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 06/23/2023] [Accepted: 07/14/2023] [Indexed: 07/21/2023] Open
Abstract
PURPOSE
To evaluate the vertical misfit, stress distribution around dental implants, and cantilever fracture strength of 3-unit implant-supported cantilever fixed partial dentures (FPDs) using frameworks made from different materials and manufacturing techniques.
MATERIALS AND METHODS
Forty FPDs were fabricated and divided into 5 groups (n = 8) based on the framework material used: LAS Co-Cr (Conventional casting-laser welding); TIG Co-Cr (Conventional casting -TIG welding); OP Co-Cr (Conventional casting-one-piece); CAD Co-Cr (CAD-CAM); and CAD Zr (CAD-CAM ZrO2). The vertical misfit was evaluated before porcelain application (T1) and before (T2), and after thermomechanical cycling (T3) by stereomicroscopy. Cantilever fracture strength was tested with a 50 kN (5000 kgf) load cell at a crosshead speed of 0.5 mm/min. Qualitative and quantitative photoelastic analysis was performed to evaluate stress distribution at seven specific points in five FPDs (n = 1/group) subjected to occlusal loading.
RESULTS
Only the molar showed interaction among the three factors (G × S × T; F(20.932) = 1.630; p = 0.044). Thermomechanical cycling (T2 vs. T3) had a significant effect on intra-group vertical misfit in molar, especially in LAS Co-Cr (Δ = 5.87; p = 0.018) and OP Co-Cr (Δ = 5.39; p = 0.007), with no significant effect in premolar (p > 0.05). Ceramic application combined with thermomechanical cycling (T1 vs. T3) caused a significant intra-group increase in vertical misfit in all groups, both in the molar and premolar (p < 0.05). OP Co-Cr was associated with greater vertical misfit and stress concentration. Frameworks manufactured by the CAD-CAM system exhibited lower vertical misfit and better stress distribution. FPDs with metal frameworks (>410.83 ± 72.26 N) showed significantly higher fracture strength (p < 0.05) than zirconia (277.47 ± 39.10 N), and the first signs of ceramic veneering fracture were observed around 900 N.
CONCLUSIONS
FPDs with frameworks manufactured using a CAD-CAM system appear to be associated with lower vertical misfit and better stress distribution, although the section of the frameworks followed by welding may be a viable alternative. In addition, metal frameworks exhibit high fracture strength.