1
|
Abad-Coronel C, Vélez Chimbo D, Lupú B, Pacurucu M, Fárez MV, Fajardo JI. Comparative Analysis of the Structural Weights of Fixed Prostheses of Zirconium Dioxide, Metal Ceramic, PMMA and 3DPP Printing Resin-Mechanical Implications. Dent J (Basel) 2023; 11:249. [PMID: 37999013 PMCID: PMC10670660 DOI: 10.3390/dj11110249] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 09/11/2023] [Accepted: 10/23/2023] [Indexed: 11/25/2023] Open
Abstract
The aim of this study was to determine the mechanical implications of four-unit fixed dental prostheses (FDPs) made of (1) monolithic zirconium dioxide (ZR O2), (2) polymethylmethacrylate (PMMA), (3) metal ceramic (PFM) and (4) impression resin (3DPP). METHODS Four groups were studied with eight samples for each material (n: 32). Each structure was weighed, subjected to compressive tests and analyzed using 3D FEA. RESULTS PMMA presented the lowest structural weight (1.33 g), followed by 3DPP (1.98 g), ZR O2 (6.34 g) and PFM (6.44 g). In fracture tests, PMMA presented a compressive strength of 2104.73 N and a tension of 351.752 MPa; followed by PFM, with a strength of 1361.48 N and a tension of 227.521 MPa; ZR O2, with a strength of 1107.63 N and a tension of 185.098 MPa; and 3DPP, with a strength of 1000.88 N and a tension of 143.916 MPa. According to 3D FEA, 3DPP presented the lowest degree of deformation (0.001 mm), followed by PFM (0.011 mm), ZR O2 (0.168 mm) and PMMA (1.035 mm). CONCLUSIONS The weights of the materials did not have a direct influence on the mean values obtained for strength, stress or strain. Since the performance was related to the tension and forces supported by the structures in critical zones, the importance of considering design factors is clear. In vitro and 3D FEA assays allowed us to simulate different scenarios for the mechanical properties of certain materials before evaluating them clinically. Thus, they can generate predictions that would allow for the design of a better research methodology in future clinical trials.
Collapse
Affiliation(s)
- Cristian Abad-Coronel
- Research Group on CAD/CAM Materials and Digital Dentistry, Faculty of Dentistry, University of Cuenca, Cuenca 10107, Ecuador
| | - David Vélez Chimbo
- Facultad de Odontología, Universidad de Cuenca, Cuenca 10107, Ecuador; (D.V.C.); (B.L.); (M.P.)
| | - Billy Lupú
- Facultad de Odontología, Universidad de Cuenca, Cuenca 10107, Ecuador; (D.V.C.); (B.L.); (M.P.)
| | - Miguel Pacurucu
- Facultad de Odontología, Universidad de Cuenca, Cuenca 10107, Ecuador; (D.V.C.); (B.L.); (M.P.)
| | - Marco V. Fárez
- New Materials and Transformation Processes Research Group GiMaT, Universidad Politécnica Salesiana, Cuenca 010105, Ecuador (J.I.F.)
| | - Jorge I. Fajardo
- New Materials and Transformation Processes Research Group GiMaT, Universidad Politécnica Salesiana, Cuenca 010105, Ecuador (J.I.F.)
| |
Collapse
|
2
|
Yang Y, Liu Y, Yuan X, Ren M, Chen X, Luo L, Zheng L, Liu Y. Three-dimensional finite element analysis of stress distribution on short implants with different bone conditions and osseointegration rates. BMC Oral Health 2023; 23:220. [PMID: 37061667 PMCID: PMC10105927 DOI: 10.1186/s12903-023-02945-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 04/05/2023] [Indexed: 04/17/2023] Open
Abstract
OBJECTIVE This experiment aimed to investigate the effects of bone conditions and osseointegration rates on the stress distribution of short implants using finite element analysis and also to provide some reference for the application of short implants from a biomechanical prospect. MATERIALS AND METHODS Anisotropic jaw bone models with three bone conditions and 4.1 × 6 mm implant models were created, and four osseointegration rates were simulated. Stress and strain for the implants and jaws were calculated during vertical or oblique loading. RESULTS The cortical bone area around the implant neck was most stressed. The maximum von Mises stress in cortical bone increased with bone deterioration and osseointegration rate, with maximum values of 144.32 MPa and 203.94 MPa for vertical and inclined loading, respectively. The osseointegration rate had the greatest effect on the maximum principal stress in cortical bone of type III bone, with its value increasing by 63.8% at a 100% osseointegration rate versus a 25% osseointegration rate. The maximum and minimum principal stresses under inclined load are 1.3 ~ 1.7 and 1.4 ~ 1.8 times, respectively, those under vertical load. The stress on the jaw bone did not exceed the threshold when the osseointegration rate was ≥ 50% for Type II and 100% for Type III. High strain zones are found in cancellous bone, and the maximum strain increases as the bone condition deteriorate and the rate of osseointegration decreases. CONCLUSIONS The maximum stress in the jaw bone increases as the bone condition deteriorates and the osseointegration rate increases. Increased osseointegration rate reduces cancellous bone strain and improves implant stability without exceeding the yield strength of the cortical bone. When the bone condition is good, and the osseointegration ratio is relatively high, 6 mm short implants can be used. In clinical practice, incline loading is an unfavorable loading condition, and axial loading should be used as much as possible.
Collapse
Affiliation(s)
- Yunhe Yang
- Graduate School of Dalian Medical University, Dalian, China
| | - Yuchen Liu
- Department of Engineering Mechanics, Dalian University of Technology, Dalian, China
| | - Xi Yuan
- Graduate School of Dalian University, Dalian, China
| | - Mingfa Ren
- Department of Engineering Mechanics, Dalian University of Technology, Dalian, China
- State Key Laboratory of Structural Analysis for Industrial Equipment, Dalian University of Technology, Dalian, China
| | - Xiaodong Chen
- Department of Prosthodontics, Dalian Stomatological Hospital, Dalian, 116021, China
| | - Lailong Luo
- Department of Engineering Mechanics, Dalian University of Technology, Dalian, China
| | - Lang Zheng
- Graduate School of Dalian University, Dalian, China
| | - Yang Liu
- Department of Prosthodontics, Dalian Stomatological Hospital, Dalian, 116021, China.
| |
Collapse
|
3
|
A Systematic Study of Restorative Crown-Materials Combinations for Dental Implants: Characterization of Mechanical Properties under Dynamic Loads. Int J Mol Sci 2022; 23:ijms23158769. [PMID: 35955903 PMCID: PMC9369216 DOI: 10.3390/ijms23158769] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 07/28/2022] [Accepted: 08/05/2022] [Indexed: 11/16/2022] Open
Abstract
This study aimed to find the optimum mechanical characteristics of the restorative materials for the manufacture of implant crowns subjected to impact loading when different combinations of materials are used for the inner and outer crown. Several combinations of external–internal crown restorative materials were analyzed. The dynamic stresses at eight different zones of a dental implant subjected to an impact load and the influence of several mechanical properties, such as the Young’s modulus, Poisson’s ratio, density, and initial velocity, were analyzed and compared. A detailed 3D model was created, including the crown, the retention screw, the implant, and a mandible section. The model was then built by importing the 3D geometries from CAD software. The whole 3D model was carefully created in order to guarantee a finite element mesh that produced results adjusted to physical reality. Then, we conducted a numerical simulation using the finite element method (FEM). The results of the FEM analysis allowed for evaluating the effect that different combinations of restorative materials and mechanical properties had on the stress distribution in various regions of the implant. The choice of restorative material is a factor to be considered in order to preserve the integrity of osseointegration. Restorative materials transfer more or less stress to the dental implant and surrounding bone, depending on their stiffness. Therefore, an inadequate Young’s modulus of the rehabilitation material can affect the survival of the implant over time. Eight interactive graphics were provided on a web-based surface platform to help clinical dentists, researchers, and manufacturers to select the best restorative materials combination for the crown.
Collapse
|
4
|
de Matos JDM, Queiroz DA, Nakano LJN, Andrade VC, Ribeiro NDCR, Borges ALS, Bottino MA, Lopes GDRS. Bioengineering Tools Applied to Dentistry: Validation Methods for In Vitro and In Silico Analysis. Dent J (Basel) 2022; 10:dj10080145. [PMID: 36005243 PMCID: PMC9406698 DOI: 10.3390/dj10080145] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 07/06/2022] [Accepted: 07/27/2022] [Indexed: 11/16/2022] Open
Abstract
This study aimed to evaluate the use of bioengineering tools, finite element analysis, strain gauge analysis, photoelastic analysis, and digital image correlation, in computational studies with greater validity and reproducibility. A bibliographic search was performed in the main health databases PUBMED and Scholar Google, in which different studies, among them, laboratory studies, case reports, systematic reviews, and literature reviews, which were developed in living individuals, were included. Therefore, articles that did not deal with the use of finite element analysis, strain gauge analysis, photoelastic analysis, and digital image correlation were excluded, as well as their use in computational studies with greater validity and reproducibility. According to the methodological analysis, it is observed that the average publication of articles in the Pubmed database was 2.03 and with a standard deviation of 1.89. While in Google Scholar, the average was 0.78 and the standard deviation was 0.90. Thus, it is possible to verify that there was a significant variation in the number of articles in the two databases. Modern dentistry finds in finite element analysis, strain gauge, photoelastic and digital image correlation a way to analyze the biomechanical behavior in dental materials to obtain results that assist to obtain rehabilitations with favorable prognosis and patient satisfaction.
Collapse
Affiliation(s)
- Jefferson David Melo de Matos
- Center for Dental Biomaterials, Department of Restorative Dental Sciences, University of Florida (UF Health), Gainesville, FL 32610, USA
- Department of Biomaterials, Dental Materials, and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos 12245-000, Brazil
| | - Daher Antonio Queiroz
- Department of Restorative Dentistry & Prosthodontics, The University of Texas Health Science Center at Houston (UTHealth) School of Dentistry, Houston, TX 77054, USA
- Correspondence:
| | - Leonardo Jiro Nomura Nakano
- Department of Biomaterials, Dental Materials, and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos 12245-000, Brazil
| | - Valdir Cabral Andrade
- Department of Dentistry and Oral and Maxillo Facial Surgery, Universidade Federal de Juiz de Fora UFJF, Governador Valadares 36036-900, Brazil
| | - Nathália de Carvalho Ramos Ribeiro
- Department of Biomaterials, Dental Materials, and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos 12245-000, Brazil
- Department of Dentistry, Universidade São Francisco (USF), Bragança Paulista 12916-900, Brazil
- Postgraduate Program in Dentistry, Department Dentistry, University of Taubaté (UNITAU), Taubate 12080-000, Brazil
| | - Alexandre Luiz Souto Borges
- Department of Biomaterials, Dental Materials, and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos 12245-000, Brazil
| | - Marco Antonio Bottino
- Department of Biomaterials, Dental Materials, and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos 12245-000, Brazil
| | - Guilherme da Rocha Scalzer Lopes
- Department of Biomaterials, Dental Materials, and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos 12245-000, Brazil
| |
Collapse
|
5
|
Zheng Z, Sun J, Jiang L, Wu Y, He J, Ruan W, Yan W. Influence of margin design and restorative material on the stress distribution of endocrowns: a 3D finite element analysis. BMC Oral Health 2022; 22:30. [PMID: 35120525 PMCID: PMC8817586 DOI: 10.1186/s12903-022-02063-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 01/27/2022] [Indexed: 11/10/2022] Open
Abstract
Background This study aimed to evaluate the stress distributions in endocrown restorations as applied to endodontically treated teeth (ETT), according to the factors of “margin design” (four levels) and “restorative material” (six levels). Methods Four 3D-finite elements models were constructed for endocrown restored molars considering different margin designs. Model A was prepared with a flat butt joint margin and received an endocrown with a 2.0-mm occlusal thickness. Model B was prepared with a 20° bevel margin and received an endocrown with a 2.0-mm occlusal thickness. Model C was prepared with an axial reduction and 1-mm shoulder margin and received an endocrown with a 2.0-mm occlusal thickness. Model D was prepared with an anatomic margin and received an endocrown with a 2.0-mm occlusal thickness. The following endocrown materials were used: In-Ceram Zirconia (Zr), Vita Suprinity (VS), IPS Empress (IE), Grandio blocs (GR), VisCalor bulk (VS), and CopraPeek Light (CP). The Load application (600 N) was performed at the food bolus and tooth surface during the closing phase of the chewing cycle. The results for the endocrown and tooth remnants were determined according to the von Mises stress. The failure risk of the cement layer was also calculated based on the normal stress criterion. Results Model D (with an anatomic margin) showed the greatest stress concentrations, especially in the irregular and sharp angles of the restoration and tooth remnants. The stress concentrated on the dentin was significantly lower in Model B with a 20° bevel margin (20.86 MPa), i.e., 1.3 times lower than the other three margin designs (27.80 MPa). Restorative materials with higher elastic moduli present higher stress concentrations inside the endocrown and transmit less stress to the cement layer, resulting in lower bonding failure risks. In contrast, materials with an elastic modulus similar to that of dentin presented with a more homogeneous stress distribution on the whole structure. Conclusions An endocrown with a 20° bevel margin design could be a favorable preparation option for ETT. Composite resins (GR and VC) exhibit a more even stress distribution, and seem to be more promising materials for endocrown molars.
Collapse
Affiliation(s)
- Ziting Zheng
- Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Jieli Sun
- Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, China.,Department of Stomatology, Beijing Luhe Hospital, Capital Medical University, Beijing, China
| | - Lifang Jiang
- Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Yuan Wu
- Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Jiahui He
- Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Wenhao Ruan
- Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Wenjuan Yan
- Department of Stomatology, Nanfang Hospital, Southern Medical University, Guangzhou, China.
| |
Collapse
|
6
|
Alemayehu DB, Jeng YR. Three-Dimensional Finite Element Investigation into Effects of Implant Thread Design and Loading Rate on Stress Distribution in Dental Implants and Anisotropic Bone. MATERIALS 2021; 14:ma14226974. [PMID: 34832374 PMCID: PMC8624479 DOI: 10.3390/ma14226974] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 11/06/2021] [Accepted: 11/16/2021] [Indexed: 12/18/2022]
Abstract
Variations in the implant thread shape and occlusal load behavior may result in significant changes in the biological and mechanical properties of dental implants and surrounding bone tissue. Most previous studies consider a single implant thread design, an isotropic bone structure, and a static occlusal load. However, the effects of different thread designs, bone material properties, and loading conditions are important concerns in clinical practice. Accordingly, the present study performs Finite Element Analysis (FEA) simulations to investigate the static, quasi-static and dynamic response of the implant and implanted bone material under various thread designs and occlusal loading directions (buccal-lingual, mesiodistal and apical). The simulations focus specifically on the von Mises stress, displacement, shear stress, compressive stress, and tensile stress within the implant and the surrounding bone. The results show that the thread design and occlusal loading rate have a significant effect on the stress distribution and deformation of the implant and bone structure during clinical applications. Overall, the results provide a useful insight into the design of enhanced dental implants for an improved load transfer efficiency and success rate.
Collapse
Affiliation(s)
- Dawit-Bogale Alemayehu
- Department of Biomedical Engineering, National Cheng Kung University (NCKU), Tainan 70101, Taiwan;
| | - Yeau-Ren Jeng
- Department of Biomedical Engineering, National Cheng Kung University (NCKU), Tainan 70101, Taiwan;
- School of Smart Semiconductor and Sustainable Manufacturing, National Cheng Kung University (NCKU), Tainan 70101, Taiwan
- Medical Device Innovation Center (MDIC), National Cheng Kung University (NCKU), Tainan 70101, Taiwan
- Correspondence: ; Tel.: +886-933278212
| |
Collapse
|
7
|
Bone Stress Evaluation with and without Cortical Bone Using Several Dental Restorative Materials Subjected to Impact Load: A Fully 3D Transient Finite-Element Study. MATERIALS 2021; 14:ma14195801. [PMID: 34640200 PMCID: PMC8510134 DOI: 10.3390/ma14195801] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 09/18/2021] [Accepted: 10/01/2021] [Indexed: 12/14/2022]
Abstract
Statement of problem. Previous peri-implantitis, peri-implant bone regeneration, or immediate implant placement postextraction may be responsible for the absence of cortical bone. Single crown materials are then relevant when dynamic forces are transferred into bone tissue and, therefore, the presence (or absence) of cortical bone can affect the long-term survival of the implant. Purpose: the purpose of this study is to assess the biomechanical response of dental rehabilitation when selecting different crown materials in models with and without cortical bone. Methods: several crown materials were considered for modeling six types of crown rehabilitation: full metal (MET), metal-ceramic (MCER), metal-composite (MCOM), peek-composite (PKCOM), carbon fiber-composite (FCOM), and carbon fiber-ceramic (FCCER). An impact-load dynamic finite-element analysis was carried out on all the 3D models of crowns mentioned above to assess their mechanical behavior against dynamic excitation. Implant-crown rehabilitation models with and without cortical bone were analyzed to compare how the load-impact actions affect both type of models. Results: numerical simulation results showed important differences in bone tissue stresses. The results show that flexible restorative materials reduce the stress on the bone and would be especially recommendable in the absence of cortical bone. Conclusions: this study demonstrated that more stress is transferred to the bone when stiffer materials (metal and/or ceramic) are used in implant supported rehabilitations; conversely, more flexible materials transfer less stress to the implant connection. Also, in implant-supported rehabilitations, more stress is transferred to the bone by dynamic forces when cortical bone is absent.
Collapse
|
8
|
Development of a lead foil crown delineation technique for implant rehabilitations to generate patient specific finite element model of occlusal loading points. MethodsX 2021; 8:101373. [PMID: 34430269 PMCID: PMC8374443 DOI: 10.1016/j.mex.2021.101373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 04/26/2021] [Indexed: 11/23/2022] Open
Abstract
Understanding the clinical biomechanical basis of dental implant supported functional rehabilitation of edentulous jaws improves precision, longevity and overall success of a planned treatment. Stress distribution pattern around dental implants is an important determinant for rate of bone resorption around them. During planning the treatment for most prosthetic rehabilitations, the surgeon uses a software to virtually plan the dimension, position and angulation of the implants considering only the quantity of available bone in the area of interest but does not usually consider the strain generated around the implants after prosthetically loading them. We hence hypothesise that dental implants not be subjected to abnormal strain they should be positioned and angulated not only based on volume of bone available but also based on the vector of occlusal load. The virtual FEA model to analyse the stress distribution would hence require alveolar bone with future tooth/ teeth in centric relation to be modelled. This paper proposes a simple innovative technique to develop a 3D FE model of occlusal loading surface by using a radio-opaque malleable lead foil to generate a patient specific FE model. This would greatly minimise modelling errors and also help determine the best position of the dental implant based on both the volume of bone in the CT scan and the results of FE analyses.Functional rehabilitation using dental implant supported prosthesis needs to be biomechanically analysed to know and understand the stress distribution pattern around the implant. When teeth (Loading points) are missing, patient specific virtual model of occlusal loading points cannot be generated. ‘Lead foil crown delineation technique’ helps to generate patient specific 3D model of occlusal surface for load application.
Collapse
|
9
|
A 3D Finite Element Analysis Model of Single Implant-Supported Prosthesis under Dynamic Impact Loading for Evaluation of Stress in the Crown, Abutment and Cortical Bone Using Different Rehabilitation Materials. MATERIALS 2021; 14:ma14133519. [PMID: 34202625 PMCID: PMC8269525 DOI: 10.3390/ma14133519] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 06/13/2021] [Accepted: 06/18/2021] [Indexed: 12/19/2022]
Abstract
In the literature, many researchers investigated static loading effects on an implant. However, dynamic loading under impact loading has not been investigated formally using numerical methods. This study aims to evaluate, with 3D finite element analysis (3D FEA), the stress transferred (maximum peak and variation in time) from a dynamic impact force applied to a single implant-supported prosthesis made from different materials. A 3D implant-supported prosthesis model was created on a digital model of a mandible section using CAD and reverse engineering. By setting different mechanical properties, six implant-supported prostheses made from different materials were simulated: metal (MET), metal-ceramic (MCER), metal-composite (MCOM), carbon fiber-composite (FCOM), PEEK-composite (PKCOM), and carbon fiber-ceramic (FCCER). Three-dimensional FEA was conducted to simulate the collision of 8.62 g implant-supported prosthesis models with a rigid plate at a speed of 1 m/s after a displacement of 0.01 mm. The stress peak transferred to the crown, titanium abutment, and cortical bone, and the stress variation in time, were assessed.
Collapse
|
10
|
Yoon S, Jung HJ, Knowles JC, Lee HH. Digital image correlation in dental materials and related research: A review. Dent Mater 2021; 37:758-771. [PMID: 33715864 DOI: 10.1016/j.dental.2021.02.024] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 02/23/2021] [Accepted: 02/24/2021] [Indexed: 12/16/2022]
Abstract
OBJECTIVE Digital image correlation (DIC) is a non-contact image processing technique for full-field strain measurement. Although DIC has been widely used in engineering and biomechanical fields, it is in the spotlight only recently in dental materials. Therefore, the purpose of this review paper is introducing the working principle of the DIC technique with some modifications and providing further potential applications in various dental materials and related fields. METHODS The accuracy of the algorithm depending on the environmental characteristics of the DIC technique, as well as the advantages and disadvantages of strain measurement using optical measurements, have been elaborated in dental materials and related fields. Applications to those researches have been classified into the following categories: shrinkage behavior of light-cured resin composite, resin-tooth interface, mechanical properties of tooth structure, crack extension and elastic properties of dental materials, and deformation of dental restoration and prosthesis. This classification and discussion were performed using literature survey and review based on numerous papers in the international journals published over the past 20 years. The future directions for predicting the precise deformation of dental materials under various environments, as well as limitations of the DIC technique, was presented in this review. RESULTS The DIC technique was demonstrated as a more effective tool to measure full-field polymerization shrinkage of composite resin, even in a simulated clinical condition over the existing methods. Moreover, the DIC combined with other technologies can be useful to evaluate the mechanical behavior of material-tooth interface, dentine structure and restorative and prosthetic materials with high accuracy. Three-dimensional DIC using two cameras extended the measurement range in-plane to out-of-plane, enabling measure of the strain directly on the surface of dental restorations or prosthesis. SIGNIFICANCE DIC technique is a potential tool for measuring and predicting the full-field deformation/strain of dental materials and actual prostheses in diverse clinical conditions. The versatility of DIC can replace the existing complex sensor devices in those studies.
Collapse
Affiliation(s)
- Sungsik Yoon
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Hyung-Jo Jung
- Department of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - J C Knowles
- UCL Eastman-Korea Dental Medicine Innovation Centre, Dankook University, 119 Dandaero, Cheonan, Chungnam 31116, Republic of Korea; Division of Biomaterials and Tissue Engineering, Eastman Dental Institute, University College London, London, UK
| | - Hae-Hyoung Lee
- Department of Biomaterials Science, College of Dentistry, Dankook University, 119 Dandaero, Cheonan, Chungnam 31116, Republic of Korea; Institute of Tissue Regeneration Engineering, Dankook University, 119 Dandaero, Cheonan, Chungnam 31116, Republic of Korea.
| |
Collapse
|