1
|
Yang S, Zhao Q. Dynamic tensile viscoelastic properties of porcine periodontal ligament. Eur J Oral Sci 2024; 132:e12984. [PMID: 38764177 DOI: 10.1111/eos.12984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 03/01/2024] [Indexed: 05/21/2024]
Abstract
The periodontal ligament plays a significant role in orthodontic and masticatory processes. To explicitly investigate the effects of dynamic force amplitude and frequency on the dynamic tensile properties of the periodontal ligament, in vitro tensile experiments were conducted using a dynamic mechanical analysis at various dynamic force amplitudes across a wide frequency range. Storage modulus, loss modulus, and loss factor values were measured. A Maxwell constitutive model based on modulus was established to describe the dynamic mechanical properties of the periodontal ligament. The results showed that the storage modulus ranged from 29.53 MPa to 158.24 MPa, the loss modulus ranged from 3.26 MPa to 76.16 MPa, and the loss factor values all increased with higher frequencies and higher dynamic force amplitudes. Based on the parameters obtained from the fitting results, it is evident that the short-term response has a more pronounced impact on the elastic response of the periodontal ligament than the long-term response. Increasing the dynamic force amplitude and its frequency amplified the viscous effects of the periodontal ligament and enhanced energy dissipation. The proposed constitutive model further demonstrated that the periodontal ligament acts as a viscoelastic biomaterial. These findings have implications for future research on the periodontal ligament.
Collapse
Affiliation(s)
- Song Yang
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin, China
- National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin University of Technology, Tianjin, China
| | - Qiuxu Zhao
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin, China
- National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin University of Technology, Tianjin, China
| |
Collapse
|
2
|
Wang Z, Du S, Zhu H, Yi K, Tang Z, Li Q. A finite element analysis of periodontal ligament fluid mechanics response to occlusal loading based on hydro-mechanical coupling model. Arch Oral Biol 2024; 164:106008. [PMID: 38781742 DOI: 10.1016/j.archoralbio.2024.106008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 05/12/2024] [Accepted: 05/20/2024] [Indexed: 05/25/2024]
Abstract
OBJECTIVE Considering fluid stimulation is one of the essential biomechanical signals for periodontal tissues, this study aims to characterizing fluid mechanics response during occlusal loading by a hydro-mechanical coupling model for periodontal ligament. DESIGN Models simulating periodontium with normal bone height and with intraosseous defects were built with three mechanical modules: tooth, periodontal ligament and alveolar bone. Tooth was modeled as linear elastic, and periodontal ligament and alveolar bone as a hydro-mechanical coupling model. Transient analyses under dynamic occlusal loading were performed. Fluid dynamics within periodontal ligament space was simulated and visualized by post-processing module. RESULTS Reciprocating oscillatory flow occurred within the periodontal ligament under occlusal loading. Higher pore pressure and fluid velocity were observed in furcation and apical regions compared to mid-root and cervical regions. Intraosseous defects increased pore pressure and fluid velocity within the periodontal ligament, most significantly near the defect. CONCLUSION Based on the results of the hydro-mechanical coupling model, significant oscillatory fluid motion is observed within the periodontal ligament under occlusal loading. Particularly, higher fluid velocity is evident in the furcation and apical areas. Additionally, Intraosseous defects significantly enhance fluid motion within the periodontal ligament.
Collapse
Affiliation(s)
- Zhongyu Wang
- Second Clinical Division, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology & NMPA Key Laboratory for Dental Materials, No.22, Zhongguancun South Avenue, Haidian District, Beijing
| | - Sa Du
- Second Clinical Division, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology & NMPA Key Laboratory for Dental Materials, No.22, Zhongguancun South Avenue, Haidian District, Beijing
| | - Huilin Zhu
- Second Clinical Division, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology & NMPA Key Laboratory for Dental Materials, No.22, Zhongguancun South Avenue, Haidian District, Beijing
| | - Ke Yi
- Second Clinical Division, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology & NMPA Key Laboratory for Dental Materials, No.22, Zhongguancun South Avenue, Haidian District, Beijing
| | - Zhihui Tang
- Second Clinical Division, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology & NMPA Key Laboratory for Dental Materials, No.22, Zhongguancun South Avenue, Haidian District, Beijing.
| | - Qing Li
- Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology & NMPA Key Laboratory for Dental Materials, No.22, Zhongguancun South Avenue, Haidian District, Beijing, PR China.
| |
Collapse
|
3
|
Zhang S, Liu J, Feng F, Jia Y, Xu F, Wei Z, Zhang M. Rational design of viscoelastic hydrogels for periodontal ligament remodeling and repair. Acta Biomater 2024; 174:69-90. [PMID: 38101557 DOI: 10.1016/j.actbio.2023.12.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 11/14/2023] [Accepted: 12/07/2023] [Indexed: 12/17/2023]
Abstract
The periodontal ligament (PDL) is a distinctive yet critical connective tissue vital for maintaining the integrity and functionality of tooth-supporting structures. However, PDL repair poses significant challenges due to the complexity of its mechanical microenvironment encompassing hard-soft-hard tissues, with the viscoelastic properties of the PDL being of particular interest. This review delves into the significant role of viscoelastic hydrogels in PDL regeneration, underscoring their utility in simulating biomimetic three-dimensional microenvironments. We review the intricate relationship between PDL and viscoelastic mechanical properties, emphasizing the role of tissue viscoelasticity in maintaining mechanical functionality. Moreover, we summarize the techniques for characterizing PDL's viscoelastic behavior. From a chemical bonding perspective, we explore various crosslinking methods and characteristics of viscoelastic hydrogels, along with engineering strategies to construct viscoelastic cell microenvironments. We present a detailed analysis of the influence of the viscoelastic microenvironment on cellular mechanobiological behavior and fate. Furthermore, we review the applications of diverse viscoelastic hydrogels in PDL repair and address current challenges in the field of viscoelastic tissue repair. Lastly, we propose future directions for the development of innovative hydrogels that will facilitate not only PDL but also systemic ligament tissue repair. STATEMENT OF SIGNIFICANCE.
Collapse
Affiliation(s)
- Songbai Zhang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi International Joint Research Center for Oral Diseases, Department of General Dentistry and Emergency, School of Stomatology, Fourth Military Medical University, Xi'an 710032, PR China; The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Jingyi Liu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Fan Feng
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi International Joint Research Center for Oral Diseases, Department of General Dentistry and Emergency, School of Stomatology, Fourth Military Medical University, Xi'an 710032, PR China
| | - Yuanbo Jia
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Feng Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, PR China
| | - Zhao Wei
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an 710049, PR China.
| | - Min Zhang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi International Joint Research Center for Oral Diseases, Department of General Dentistry and Emergency, School of Stomatology, Fourth Military Medical University, Xi'an 710032, PR China.
| |
Collapse
|
4
|
Demir O, Uslan I, Buyuk M, Salamci MU. Development and validation of a digital twin of the human lower jaw under impact loading by using non-linear finite element analyses. J Mech Behav Biomed Mater 2023; 148:106207. [PMID: 37922761 DOI: 10.1016/j.jmbbm.2023.106207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 10/18/2023] [Accepted: 10/20/2023] [Indexed: 11/07/2023]
Abstract
Mandibular fractures are one of the most frequently observed injuries within craniofacial region mostly due to tumor-related problems and traumatic events, often related to non-linear effects like impact loading. Therefore, a validated digital twin of the mandible is required to develop the best possible patient-specific treatment. However, there is a need to obtain a fully compatible numerical model that can reflect the patients' characteristics, be available and accessible quickly, require an acceptable level of modeling efforts and knowledge to provide accurate, robust and fast results at the same time under highly non-linear effects. In this study, a validated simulation methodology is suggested to develop a digital twin of mandible, capable of predicting the non-linear response of the biomechanical system under impact loading, which then can be utilized to design treatment strategies even for multiple fractures of the mandibular system. Using Computed Tomography data containing cranial (skull) images of a patient, a 3-dimensional mandibular model, which consists cortical and cancellous bones, disks and fossa is obtained with high accuracy that is compatible with anatomical boundaries. A Finite Element Model (FEM) of the biomechanical system is then developed for a three-level validation procedure including (A) modal analysis, (B) dynamic loading and (C) impact loading. For the modal analysis stage: Free-free vibration modes and frequencies of the system are validated against cadaver test results. For the dynamic loading stage: Two different regions of the mandible are loaded, and maximum stress levels of the system are validated against finite element analyses (FEA) results, where the first loading condition (i) transfers a 2000 N force acting on the symphysis region and, the second loading condition (ii) transfers a 2000 N force acting on the left body region. In both cases, equivalent muscle forces dependent on time are applied. For the impact loading stage: Thirteen different human mandibular models with various tooth deficiencies are used under the effects of traumatic impact forces that are generated by using an impact hammer with different initial velocities to transfer the impulse and momentum, where contact forces and fracture patterns are validated against cadaver tests. Five different anatomical regions are selected as the impact site. The results of the analyzes (modal, dynamic and impact) performed to validate the digital twin model are compared with the similar FEA and cadaver test results published in the literature and the results are found to be compatible. It has been evaluated that the digital twin model and numerical models are quite realistic and perform well in terms of predicting the biomechanical behavior of the mandible. The three-level validation methodology that is suggested in this research by utilizing non-linear FEA has provided a reliable road map to develop a digital twin of a biomechanical system with enough confidence that it can be utilized for similar structures to offer patient-specific treatments and can help develop custom or tailor-made implants or prosthesis for best compliance with the patient even considering the most catastrophic effects of impact related trauma.
Collapse
Affiliation(s)
- Osman Demir
- Gulhane Medical Design and Manufacturing Application and Research Center-SBU-METUM, University of Health Sciences, 06010, Ankara, Turkey; Department of Mechanical Engineering, Gazi University, 06570, Ankara, Turkey.
| | | | - Murat Buyuk
- Department of Engineering Sciences, Middle East Technical University, 06800, Ankara, Turkey.
| | - Metin Uymaz Salamci
- Department of Mechanical Engineering, Gazi University, 06570, Ankara, Turkey; Additive Manufacturing Technologies Research and Application Center-EKTAM, Gazi University, 06980, Ankara, Turkey.
| |
Collapse
|
5
|
Wu B, Li N, Liu M, Cheng K, Jiang D, Yi Y, Ma S, Yan B, Lu Y. Construction of Human Periodontal Ligament Constitutive Model Based on Collagen Fiber Content. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6582. [PMID: 37834722 PMCID: PMC10573969 DOI: 10.3390/ma16196582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/26/2023] [Accepted: 09/29/2023] [Indexed: 10/15/2023]
Abstract
Periodontal ligament (PDL) is mainly composed of collagen fiber bundles, and the content of collagen fiber is an important factor affecting the mechanical properties of PDL. Based on this, the purpose of this study is to explore the effect of the PDL collagen fiber content on its viscoelastic mechanical behavior. Transverse and longitudinal samples of different regions of PDL were obtained from the human maxilla. The fiber content at different regions of human PDL was quantitatively measured using image processing software, and a new viscoelastic constitutive model was constructed based on the fiber content. The nano-indentation experiment was carried out with a loading rate of 0.5 mN·s-1, a peak load of 3 mN, and a holding time of 200 s, and the model parameters were obtained through the experiment data. The results showed that with the increase of fiber content, the deformation resistance of PDL also increased, and compared with the neck and middle region, the compressive strain in the apical region of PDL was the largest. The range of reduced elastic modulus of human PDL was calculated to be 0.39~5.08 MPa. The results of the experimental data and the viscoelastic constitutive model fit well, indicating that the model can well describe the viscoelastic behavior of human PDL.
Collapse
Affiliation(s)
- Bin Wu
- College of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing 210037, China; (B.W.); (N.L.); (D.J.); (Y.Y.)
| | - Na Li
- College of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing 210037, China; (B.W.); (N.L.); (D.J.); (Y.Y.)
| | - Mao Liu
- Department of Orthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing 210029, China;
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing 210029, China
- Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing 210029, China
| | - Ke Cheng
- College of Mechanical Engineering, Southeast University, Nanjing 210018, China;
| | - Di Jiang
- College of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing 210037, China; (B.W.); (N.L.); (D.J.); (Y.Y.)
| | - Yang Yi
- College of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing 210037, China; (B.W.); (N.L.); (D.J.); (Y.Y.)
| | - Songyun Ma
- Institute of General Mechanics, RWTH-Aachen University, 52062 Aachen, Germany;
| | - Bin Yan
- Department of Orthodontics, Affiliated Hospital of Stomatology, Nanjing Medical University, Nanjing 210029, China;
- Jiangsu Province Key Laboratory of Oral Diseases, Nanjing 210029, China
- Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing 210029, China
- College of Mechanical Engineering, Southeast University, Nanjing 210018, China;
| | - Yi Lu
- College of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing 210037, China; (B.W.); (N.L.); (D.J.); (Y.Y.)
| |
Collapse
|
6
|
Armijo L, Mancl L, Dennison CR, Houg K, Romanyk D, Popowics T. In-fiber Bragg sensor measurements assess fluid effects on strain in the periodontal space of an ex-vivo swine incisor complex under mechanical loading. J Biomech 2023; 157:111729. [PMID: 37473706 DOI: 10.1016/j.jbiomech.2023.111729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 06/14/2023] [Accepted: 07/14/2023] [Indexed: 07/22/2023]
Abstract
The purpose of this study is to determine whether in-fiber Bragg grating (FBG) sensors detect changes within the periodontal ligament (PDL) of ex-vivo swine tooth-PDL-bone complex (TPBC) when manipulating fluid content. Recording strain will allow for a better understanding of the biomechanics of viscoelastic load transfer from the tooth to the PDL during chewing and/or orthodontic tooth movement, as well as replication of these dynamics in regenerated PDL tissues. FBG sensors placed within the PDL of swine incisor teeth were used to measure strain resulting from an intrusive load. Specimens were mounted in a custom platform within an MTS machine and a compressive load was applied at 0.3 mm/s to a depth of 0.5 mm and held for 10 s. Median peak strain and load and median absolute deviation (MAD) were compared: dry vs. saline (n = 19) with bias-corrected bootstrap 95% CI. Dry vs. saline conditions did not statistically differ (median peaks of 5με, 103-105 N) and recorded strains showed high repeatability (MAD of 0.82με, 0.72με, respectively). FBG sensors did not detect the fluid changes in this study, suggesting that the deformation of tissues in the PDL space collectively determine FBG strain in response to tooth loading. The repeatability of measurements demonstrates the potential for FBG sensors to assess the strain in the PDL space of an in vivo swine model.
Collapse
Affiliation(s)
- Leigh Armijo
- Dept. of Orthodontics, University of Washington School of Dentistry, Seattle, WA 98195, USA.
| | - Lloyd Mancl
- Dept. of Oral Health Sciences, University of Washington School of Dentistry, Seattle, WA 98195, USA.
| | | | - Kathryn Houg
- Dept. of Mechanical Engineering and School of Dentistry, University of Alberta, Edmonton, Alberta, Canada.
| | - Dan Romanyk
- Dept. of Mechanical Engineering and School of Dentistry, University of Alberta, Edmonton, Alberta, Canada.
| | - Tracy Popowics
- Box 357475, Dept. of Oral Health Sciences, 1959 Pacific Ave. NE, University of Washington School of Dentistry, Seattle, WA 98195, USA.
| |
Collapse
|
7
|
Maltha JC, Kuijpers-Jagtman AM. Mechanobiology of orthodontic tooth movement: An update. J World Fed Orthod 2023; 12:156-160. [PMID: 37349154 DOI: 10.1016/j.ejwf.2023.05.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 04/28/2023] [Accepted: 05/01/2023] [Indexed: 06/24/2023]
Abstract
The purpose of this review is to provide an update on the changes at the cellular and tissue level occurring during orthodontic force application. For the understanding of this process, knowledge of the mechanobiology of the periodontal ligament and the alveolar bone are essential. The periodontal ligament and alveolar bone make up a functional unit that undergoes robust changes during orthodontic tooth movement. Complex molecular signaling is responsible for converting mechanical stresses into biochemical events with a net result of bone apposition and/or bone resorption. Despite an improved understanding of mechanical and biochemical signaling mechanisms, it is largely unknown how mechanical stresses regulate the differentiation of stem/progenitor cells into osteoblast and osteoclast lineages. To advance orthodontics, it is crucial to gain a better understanding of osteoblast differentiation from mesenchymal stem/progenitor cells and osteoclastogenesis from the hematopoietic/monocyte lineage.
Collapse
Affiliation(s)
- Jaap C Maltha
- Department of Dentistry - Orthodontics and Craniofacial Biology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Anne Marie Kuijpers-Jagtman
- Department of Orthodontics, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands; Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine/Medical Faculty, University of Bern, Bern, Switzerland; Faculty of Dentistry, Universitas Indonesia, Campus Salemba, Jakarta, Indonesia.
| |
Collapse
|
8
|
Najafidoust M, Hashemi A, Oskui IZ. Effect of temperature on dynamic compressive behavior of periodontal ligament. Med Eng Phys 2023; 116:103986. [PMID: 37230701 DOI: 10.1016/j.medengphy.2023.103986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 04/04/2023] [Accepted: 04/30/2023] [Indexed: 05/27/2023]
Abstract
Periodontal ligament (PDL) attaches tooth root to the surrounding bone. Its existence between tooth and jaw bone is of utmost importance due to its significant role in absorbing and distributing physiological and para-physiological loading. According to the previous studies, various mechanical tests have been performed to characterize the mechanical properties of the PDL; however, all of them have been done at room temperature. To the best of our knowledge, this is the first study in which the testing was performed at body temperature. The present research was planned to measure the dependency of PDL's viscoelastic behavior on temperature and frequency. Three different temperatures, including body and room temperature, were opted to perform the dynamic compressive tests of the bovine PDL. In addition, a Generalized Maxwell model (GMM) was presented based on empirical outcomes. At 37 °C, amounts of loss factor were found to be greater than those in 25 °C, which demonstrates that the viscous phase of the PDL in higher temperatures plays a critical role. Likewise, by raising the temperature from 25 °C to 37 °C, the model parameters show an enlargement in the viscous part and lessening in the elastic part. It was concluded that the PDL's viscosity in body temperature is much higher than that in room temperature. This model would be functional for a more accurate computational analysis of the PDL at the body temperature (37 °C) in various loading conditions such as orthodontic simulations, mastication, and impact.
Collapse
Affiliation(s)
- Mohammad Najafidoust
- Biomedical Engineering Group, Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran; Neuroscience Research Australia and Prince of Wales Clinical School, University of New South Wales, Randwick, NSW, Australia
| | - Ata Hashemi
- Biomedical Engineering Group, Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran.
| | - Iman Z Oskui
- Biomedical Engineering Group, Faculty of Biomedical Engineering, Sahand University of Technology, Tabriz, Iran.
| |
Collapse
|
9
|
Construction of hyperelastic model of human periodontal ligament based on collagen fibers distribution. J Mech Behav Biomed Mater 2022; 135:105484. [PMID: 36179616 DOI: 10.1016/j.jmbbm.2022.105484] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 09/18/2022] [Accepted: 09/21/2022] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The human periodontal ligament (PDL) dominated by collagen fibers showed hyperelastic mechanical behavior under orthodontic force. Despite previous researches on the hyperelastic model of PDL, there were certain limitations because of the types of samples and the ignorance of distribution of collagen fibers. Therefore, the aim of this study was to quantify the effect of collagen fibers distribution of human PDL on its hyperelastic behavior. METHODS A total of 6 human PDL samples of root neck, root middle and root apex were cut from human maxillary central incisor and lateral incisor. The spatial angles of collagen fibers were observed by optical microscope, the hyperelastic model was constructed combined with the observation results. The quasi-static uniaxial tensile tests with displacement load 0.05 mm/min were carried out, and the test data were used to identify the parameters of model. RESULTS The mechanical behavior of human PDL conformed to the trend of hyperelastic materials, and greatly depended on the spatial angles of internal collagen fibers. The R2 value statistical fit of the constitutive model to the data is excellent (R2 > 0.98). This model could excellently describe the hyperelastic properties of human PDL. SIGNIFICANCE In this study, we quantitatively described the effect of spatial distribution of collagen fibers on the mechanical properties of human PDL. The accuracy of this model was verified by the uniaxial test data, and the relevant model parameters were acquired, which have certain reference value in subsequent researches on hyperelasticity of human PDL and clinical treatment.
Collapse
|
10
|
Wu J, Liu Y, Li B, Dong X. Development and verification of a constitutive model for human periodontal ligament based on finite element analysis. Comput Methods Biomech Biomed Engin 2021; 25:1051-1062. [PMID: 34756127 DOI: 10.1080/10255842.2021.1999426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
This study aimed to develop a constitutive model for human periodontal ligament (PDL) by combining the hyperelastic and viscosity models. We performed the finite element analysis (FEA) to simulate the experimental processes of the PDL in vitro and in vivo tests to verify the developed model. The FEA results indicated that the simulative curves were consistent with the experimental curves in the PDL in vitro tests. Moreover, for the in vivo measurements, the simulative result of 0.6258 N was similar to the experimental value of 0.65 N. The study results can help orthodontists better understand the biomechanical characteristics of PDL.
Collapse
Affiliation(s)
- Jianlei Wu
- Research Center of Mould Precision Machining & Intelligent Manufacturing Application, Ningbo Polytechnic, Ningbo, China
| | - Yunfeng Liu
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, China.,Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou, China
| | - Boxiu Li
- Department of Orthodontics, Second Affiliated Hospital of Zhejiang University College of Medical, Hangzhou, China
| | - Xingtao Dong
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, China.,Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou, China
| |
Collapse
|
11
|
Ovy EG, Romanyk DL, Flores Mir C, Westover L. Modelling and evaluating periodontal ligament mechanical behaviour and properties: A scoping review of current approaches and limitations. Orthod Craniofac Res 2021; 25:199-211. [PMID: 34355507 DOI: 10.1111/ocr.12527] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 08/02/2021] [Indexed: 11/29/2022]
Abstract
This scoping review is intended to synthesize the techniques proposed to model the tooth-periodontal ligament-bone complex (TPBC), while also evaluating the suggested periodontal ligament (PDL) material properties. It is concentrated on the recent advancements on the PDL and TPBC models, while identifying the advantages and limitations of the proposed approaches. Systematic searches were conducted up to December 2020 for articles that proposed PDL models to assess orthodontic tooth movement in Compendex, Web of Science, EMBASE, MEDLINE, PubMed, ScienceDirect, Google Scholar and Scopus databases. Although there have been many studies focused on the evaluation of PDL material properties through numerous modelling approaches, only a handful of approaches have been identified to investigate the interface properties of the PDL as a complete dynamical system (TPBC models). Past reviews on the analytical and experimental determination of the PDL properties already show a concerning range in reported output values-some nearly six orders of magnitude in difference-that strongly suggested the need for further investigation. Surprisingly, it has not yet been possible to determine a narrower range of values for the PDL material properties. Moreover, very few scientific approaches address the TPBC as an integrated complex system model. In consequence, current methods for capturing the PDL material behaviour in a clinical setting are limited and inconclusive. This synthesis encourages more systematic, pragmatic and phenomenological research in this area.
Collapse
Affiliation(s)
- Enaiyat Ghani Ovy
- Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Dan L Romanyk
- Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada
| | - Carlos Flores Mir
- Department of Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Lindsey Westover
- Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|