Lu H, Liu Y, Yang F, Wu D, Qi J, Ji Y, Hu M. The value of real-time shear wave elastography in spontaneous preterm birth. Medicine (Baltimore) 2024; 103:e39288. [PMID: 39151541 PMCID: PMC11332725 DOI: 10.1097/md.0000000000039288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/10/2024] [Accepted: 07/23/2024] [Indexed: 08/19/2024] Open
Abstract
This study aimed to investigate the predictive value of real-time shear wave elastography (SWE) for spontaneous preterm birth (SPB). This study prospectively selected 175 women with singleton pregnancies at 16 to 36 weeks of gestation. Cervical length (CL) and uterocervical angle (UCA) were measured using transvaginal ultrasonography. Real-time shear wave elastography was used to measure Young's modulus values, including the average Young's modulus (Emean) and the maximum Young's modulus (Emax) at 4 points: point A on the inner lip of the cervical os, point B on the outer lip of the cervical os, point C on the inner lip of the external os, and point D on the outer lip of the external os. Receiver operating characteristic (ROC) curve analysis was performed to compare the accuracy of Young's modulus values at the 4 points, CL, and UCA in predicting SPB. Significant variables were used to construct a binary logistic regression model to predict the multifactorial predictive value of SPB, which was evaluated using an ROC curve. A total 176 valid cases, including 160 full-term pregnancies and 16 SPB, were included in this study. Receiver operating characteristic curve analysis revealed that Emean at point A, as well as Emean and Emax at point D, had a relatively high accuracy in diagnosing SPB, with area under the curve values of 0.704, 0.708, and 0.706, respectively followed by CL (0.670), SWE at point C (Emean 0.615, Emax 0.565), SWE at point B (Emean 0.577, Emax 0.584), and UCA (0.476). Binary logistic regression analysis showed that comorbidities during pregnancy (including diabetes mellitus, hypertension, cholestasis and thyroid dysfunction), CL, and Emean at point A were independent predictors of preterm birth. In addition, the AUC value of the logistic regression model's ROC curve was 0.892 (95% CI: 0.804-0.981), with a sensitivity of 0.867, specificity of 0.792, and Youden's index of 0.659, indicating that the regression model has good predictive ability for SPB. Real-time shear wave elastography showed a higher predictive value for SPB than CL and UCA. The SWE combined with CL and comorbidities during pregnancy model has a good predictive ability for SPB.
Collapse
Affiliation(s)
- Huiling Lu
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Yang Liu
- Department of Gynecology, Baoji Central Hospital, Shaanxi, China
| | - Fangrui Yang
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Dan Wu
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Jiarui Qi
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Yonghao Ji
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| | - Mengli Hu
- Department of Ultrasonography, Baoji Central Hospital, Shaanxi, China
| |
Collapse
|
2
|
Callejas A, Faris I, Torres J, Rus G. Nonlinear fourth-order elastic characterization of the cornea using torsional wave elastography. Phys Eng Sci Med 2023; 46:1489-1501. [PMID: 37642939 DOI: 10.1007/s13246-023-01314-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 07/26/2023] [Indexed: 08/31/2023]
Abstract
Measuring the mechanical nonlinear properties of the cornea remains challenging due to the lack of consensus in the methodology and in the models that effectively predict its behaviour. This study proposed developing a procedure to reconstruct nonlinear fourth-order elastic properties of the cornea based on a mathematical model derived from the theory of Hamilton et al. and using the torsional wave elastography (TWE) technique. In order to validate its diagnostic capability of simulated pathological conditions, two different groups were studied, non-treated cornea samples (n=7), and ammonium hydroxide ([Formula: see text]) treated samples (n=7). All the samples were measured in-plane by a torsional wave device by increasing IOP from 5 to 25 mmHg with 5 mmHg steps. The results show a nonlinear variation of the shear wave speed with the IOP, with higher values for higher IOPs. Moreover, the shear wave speed values of the control group were higher than those of the treated group. The study also revealed significant differences between the control and treated groups for the Lamé parameter [Formula: see text] (25.9-6.52 kPa), third-order elastic constant A (215.09-44.85 kPa), and fourth-order elastic constant D (523.5-129.63 kPa), with p-values of 0.010, 0.024, and 0.032, respectively. These findings demonstrate that the proposed procedure can distinguish between healthy and damaged corneas, making it a promising technique for detecting diseases associated with IOP alteration, such as corneal burns, glaucoma, or ocular hypertension.
Collapse
Affiliation(s)
- Antonio Callejas
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada, 18071, Spain.
- TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada, 18001, Spain.
| | - Inas Faris
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada, 18071, Spain
- TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada, 18001, Spain
| | - Jorge Torres
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada, 18071, Spain
- TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada, 18001, Spain
| | - Guillermo Rus
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada, 18071, Spain
- TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada, 18001, Spain
- Excellence Research Unit "ModelingNature" (MNat), Universidad de Granada, Granada, 18001, Spain
| |
Collapse
|
3
|
Yoshida K. Bioengineering and the cervix: The past, current, and future for addressing preterm birth. Curr Res Physiol 2023; 6:100107. [PMID: 38107784 PMCID: PMC10724223 DOI: 10.1016/j.crphys.2023.100107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 08/23/2023] [Accepted: 09/20/2023] [Indexed: 12/19/2023] Open
Abstract
The uterine cervix plays two important but opposing roles during pregnancy - as a mechanical barrier that maintains the fetus for nine months and as a compliant structure that dilates to allow for the delivery of a baby. In some pregnancies, however, the cervix softens and dilates prematurely, leading to preterm birth. Bioengineers have addressed and continue to address the lack of reduction in preterm birth rates by developing novel technologies to diagnose, prevent, and understand premature cervical remodeling. This article highlights these existing and emerging technologies and concludes with open areas of research related to the cervix and preterm birth that bioengineers are currently well-positioned to address.
Collapse
Affiliation(s)
- Kyoko Yoshida
- Department of Biomedical Engineering, University of Minnesota, 7-105 Nils Hasselmo Hall, 312 Church Street SE, Minneapolis, MN, 55455, USA
| |
Collapse
|
4
|
Torres J, Callejas A, Gomez A, Rus G. Optical micro-elastography with magnetic excitation for high frequency rheological characterization of soft media. ULTRASONICS 2023; 132:107021. [PMID: 37141701 DOI: 10.1016/j.ultras.2023.107021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 03/22/2023] [Accepted: 04/18/2023] [Indexed: 05/06/2023]
Abstract
The propagation of shear waves in elastography at high frequency (>3 kHz) in viscoelastic media has not been extensively studied due to the high attenuation and technical limitations of current techniques. An optical micro-elastography (OME) technique using magnetic excitation for generating and tracking high frequency shear waves with enough spatial and temporal resolution was proposed. Ultrasonics shear waves (above 20 kHz) were generated and observed in polyacrylamide samples. A cutoff frequency, from where the waves no longer propagate, was observed to vary depending on the mechanical properties of the samples. The ability of the Kelvin-Voigt (KV) model to explain the high cutoff frequency was investigated. Two alternative measurement techniques, Dynamic Mechanical Analysis (DMA) and Shear Wave Elastography (SWE), were used to complete the whole frequency range of the velocity dispersion curve while avoid capturing guided waves in the low frequency range (<3 kHz). The combination of the three measurement techniques provided rheology information from quasi-static to ultrasonic frequency range. A key observation was that the full frequency range of the dispersion curve was necessary if one wanted to infer accurate physical parameters from the rheological model. By comparing the low frequency range with the high frequency range, the relative errors for the viscosity parameter could reach 60 % and they could be higher with higher dispersive behavior. The high cutoff frequency may be predicted in materials that follow a KV model over their entire measurable frequency range. The mechanical characterization of cell culture media could benefit from the proposed OME technique.
Collapse
Affiliation(s)
- Jorge Torres
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada 18071, Spain; TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada 18001, Spain.
| | - Antonio Callejas
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada 18071, Spain; TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada 18001, Spain
| | - Antonio Gomez
- Department of Mechanical Engineering, University College London, London WC1E 6BT, UK
| | - Guillermo Rus
- Ultrasonics Lab (TEP-959), Department of Structural Mechanics, University of Granada, Granada 18071, Spain; TEC-12 group, Instituto de Investigación Biosanitaria, ibs.Granada 18001, Spain; Excellence Research Unit "ModelingNature" (MNat), Universidad de Granada, Granada 18001, Spain
| |
Collapse
|
5
|
Poul SS, Ormachea J, Ge GR, Parker KJ. Comprehensive experimental assessments of rheological models' performance in elastography of soft tissues. Acta Biomater 2022; 146:259-273. [PMID: 35525481 DOI: 10.1016/j.actbio.2022.04.047] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 04/26/2022] [Accepted: 04/28/2022] [Indexed: 02/08/2023]
Abstract
Elastography researchers have utilized several rheological models to characterize soft tissue viscoelasticity over the past thirty years. Due to the frequency-dependent behavior of viscoelastic parameters as well as the different techniques and frequencies employed in various studies of soft tissues, rheological models have value in standardizing disparate techniques via explicit mathematical representations. However, the important question remains: which of the several available models should be considered for widespread adoption within a theoretical framework? We address this by evaluating the performance of three well established rheological models to characterize ex vivo bovine liver tissues: the Kelvin-Voigt (KV) model as a 2-parameter model, and the standard linear solid (SLS) and Kelvin-Voigt fractional derivative (KVFD) models as 3-parameter models. The assessments were based on the analysis of time domain behavior (using stress relaxation tests) and frequency domain behavior (by measuring shear wave speed (SWS) dispersion). SWS was measured over a wide range of frequency from 1 Hz to 1 kHz using three different tests: (i) harmonic shear tests using a rheometer, (ii) reverberant shear wave (RSW) ultrasound elastography scans, and (iii) RSW optical coherence elastography scans, with each test targeting a distinct frequency range. Our results demonstrated that the KVFD model produces the only mutually consistent rendering of time and frequency domain data for liver. Furthermore, it reduces to a 2-parameter model for liver (correspondingly to a 2-parameter "spring-pot" or power-law model for SWS dispersion) and provides the most accurate predictions of the material viscoelastic behavior in time (>98% accuracy) and frequency (>96% accuracy) domains. STATEMENT OF SIGNIFICANCE: Rheological models are applied in quantifying tissues viscoelastic properties. This study is unique in presenting comprehensive assessments of rheological models.
Collapse
|
6
|
Gomez A, Hurtado M, Callejas A, Torres J, Saffari N, Rus G. Experimental Evidence of Generation and Reception by a Transluminal Axisymmetric Shear Wave Elastography Prototype. Diagnostics (Basel) 2021; 11:diagnostics11040645. [PMID: 33918357 PMCID: PMC8067333 DOI: 10.3390/diagnostics11040645] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Revised: 03/20/2021] [Accepted: 03/30/2021] [Indexed: 01/30/2023] Open
Abstract
Experimental evidence on testing a non-ultrasonic-based probe for a new approach in transluminal elastography was presented. The proposed modality generated shear waves by inducing oscillatory rotation on the lumen wall. Detection of the propagated waves was achieved at a set of receivers in mechanical contact with the lumen wall. The excitation element of the probe was an electromagnetic rotational actuator whilst the sensing element was comprised by a uniform anglewise arrangement of four piezoelectric receivers. The prototype was tested in two soft-tissue-mimicking phantoms that contained lumenlike conduits and stiffer inclusions. The shear wave speed of the different components of the phantoms was characterized using shear wave elastography. These values were used to estimate the time-of-flight of the expected reflections. Ultrafast ultrasound imaging, based on Loupas’ algorithm, was used to estimate the displacement field in transversal planes to the lumenlike conduit and to compare against the readouts from the transluminal transmission–reception tests. Experimental observations between ultrafast imaging and the transluminal probe were in good agreement, and reflections due to the stiffer inclusions were detected by the transluminal probe. The obtained experimental evidence provided proof-of-concept for the transluminal elastography probe and encouraged further exploration of clinical applications.
Collapse
Affiliation(s)
- Antonio Gomez
- Department of Mechanical Engineering, University College London, London WC1E 6BT, UK; (A.G.); (N.S.)
| | - Manuel Hurtado
- Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (M.H.); (J.T.); (G.R.)
| | - Antonio Callejas
- Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (M.H.); (J.T.); (G.R.)
- Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain
- Correspondence:
| | - Jorge Torres
- Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (M.H.); (J.T.); (G.R.)
- Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain
| | - Nader Saffari
- Department of Mechanical Engineering, University College London, London WC1E 6BT, UK; (A.G.); (N.S.)
| | - Guillermo Rus
- Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (M.H.); (J.T.); (G.R.)
- Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain
- Excellence Research Unit “ModelingNature” (MNat), Universidad de Granada, 18071 Granada, Spain
| |
Collapse
|