Horsten DL, van Gastel DM, Maassen LW, Koks CAM, Veersema S, Bongers MY. Perioperative findings and complications in Essure® removal surgery.
Eur J Obstet Gynecol Reprod Biol 2021;
263:1-6. [PMID:
34129961 DOI:
10.1016/j.ejogrb.2021.05.035]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 05/18/2021] [Accepted: 05/20/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE
To analyze perioperative findings and complications in surgical removal of Essure® microinserts.
STUDY DESIGN
A prospective cohort study of 274 patients who underwent surgical removal of Essure® microinserts. Outcomes of the surgical procedures and complications were entered into a digital case report form (CRF) by the surgeon and registered in an online database. Results were analyzed through IBM SPSS Statistics using descriptive statistical methods.
RESULTS
During laparoscopic inspection in 15.4 % of fallopian tubes (n = 80) a chicken wing sign (the fallopian tube folding over the most distal part of the microinsert) was seen. Partial tubal perforation and total tubal perforation with migration of the microinsert out of the fallopian tube were seen in respectively 1.9 % (n = 10) and 0.2 % (n = 1) of cases. The microinserts were removed by laparoscopic tubotomy and extraction, followed by bilateral salpingectomy in 91.2 % of cases. In 7.3 % of cases (n = 20) a hysterectomy and bilateral salpingectomy was performed for additional indications than solely Essure® removal. Four microinserts were taken out entirely by means of hysteroscopy (1.5 %). We did not see major surgery related complications, however we found a risk of minor complications during or after surgery of respectively 1.6 % (n = 4) and 3.9 % (n = 10).
CONCLUSIONS
During laparoscopic inspection, abnormalities were seen in 22.8 % (n = 119) of fallopian tubes, of which the chicken wing sign was the most common. Partial and total tubal perforation with migration of the microinsert were rare. The complication rate of Essure® removal surgery in our prospective study is low and complications are minor, without any major complication. However, while counseling patients with a request for surgical removal of Essure® microinserts, these results should be mentioned.