1
|
Wang Z, Huang P, Zheng F, Yu H, Li Y, Qiu Z, Gai L, Liu Z, Bai S. Research on Spatial Localization Method of Magnetic Nanoparticle Samples Based on Second Harmonic Waves. MICROMACHINES 2024; 15:1218. [PMID: 39459091 PMCID: PMC11509944 DOI: 10.3390/mi15101218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2024] [Revised: 09/27/2024] [Accepted: 09/27/2024] [Indexed: 10/28/2024]
Abstract
Existing magnetic tracer detection systems primarily rely on fundamental wave signal acquisition using non-differential sensor configurations. These sensors are highly susceptible to external interference and lack tomographic localization capabilities, hindering their clinical application. To address these limitations, this paper presents a novel method for achieving the deep spatial localization of tracers. The method exploits second harmonic signal detection at non-zero field points. By considering the combined nonlinear characteristics of the coil's axial spatial magnetic field distribution and the Langevin function, a correlation model linking the signal peak and bias field is established. This model enables the determination of the tracer's precise spatial location. Building on this framework, a handheld device for localizing magnetic nanoparticle tracers was developed. The device harnesses the second harmonic response generated by coupling an AC excitation field with a DC bias field. Our findings demonstrate that under conditions of reduced coil turns and weak excitation fields, the DC bias field exhibits exclusive dependence on the axial distance of the detection point, independent of particle concentration. This implies that the saturated DC bias field corresponding to the second harmonic signal can be used to determine the magnetic nanoparticle sample detection depth. The experimental results validated the method's high accuracy, with axial detection distance and concentration reduction errors of only 4.8% and 4.1%, respectively. This research paves the way for handheld probes capable of tomographic tracer detection, offering a novel approach for advancing magnetically sensitive biomedical detection technologies.
Collapse
Affiliation(s)
| | - Ping Huang
- School of Information Science and Engineering, Shenyang University of Technology, Shenyang 110870, China; (Z.W.); (F.Z.); (H.Y.); (Y.L.); (Z.Q.); (L.G.); (Z.L.)
| | | | | | | | | | | | | | - Shi Bai
- School of Information Science and Engineering, Shenyang University of Technology, Shenyang 110870, China; (Z.W.); (F.Z.); (H.Y.); (Y.L.); (Z.Q.); (L.G.); (Z.L.)
| |
Collapse
|
2
|
2D Quantitative Imaging of Magnetic Nanoparticles by an AC Biosusceptometry Based Scanning Approach and Inverse Problem. SENSORS 2021; 21:s21217063. [PMID: 34770373 PMCID: PMC8587841 DOI: 10.3390/s21217063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 10/20/2021] [Accepted: 10/21/2021] [Indexed: 01/08/2023]
Abstract
The use of magnetic nanoparticles (MNPs) in biomedical applications requires the quantitative knowledge of their quantitative distribution within the body. AC Biosusceptometry (ACB) is a biomagnetic technique recently employed to detect MNPs in vivo by measuring the MNPs response when exposed to an alternate magnetic field. The ACB technique presents some interesting characteristics: non-invasiveness, low operational cost, high portability, and no need for magnetic shielding. ACB conventional methods until now provided only qualitative information about the MNPs’ mapping in small animals. We present a theoretical model and experimentally demonstrate the feasibility of ACB reconstructing 2D quantitative images of MNPs’ distributions. We employed an ACB single-channel scanning approach, measuring at 361 sensor positions, to reconstruct MNPs’ spatial distributions. For this, we established a discrete forward problem and solved the ACB system’s inverse problem. Thus, we were able to determine the positions and quantities of MNPs in a field of view of 5×5×1 cm3 with good precision and accuracy. The results show the ACB system’s capabilities to reconstruct the quantitative spatial distribution of MNPs with a spatial resolution better than 1 cm, and a sensitivity of 1.17 mg of MNPs fixed in gypsum. These results show the system’s potential for biomedical application of MNPs in several studies, for example, electrochemical-functionalized MNPs for cancer cell targeting, quantitative sensing, and possibly in vivo imaging.
Collapse
|
3
|
Karpavičius A, Coene A, Bender P, Leliaert J. Advanced analysis of magnetic nanoflower measurements to leverage their use in biomedicine. NANOSCALE ADVANCES 2021; 3:1633-1645. [PMID: 36132562 PMCID: PMC9417518 DOI: 10.1039/d0na00966k] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 02/04/2021] [Indexed: 05/08/2023]
Abstract
Magnetic nanoparticles are an important asset in many biomedical applications ranging from the local heating of tumours to targeted drug delivery towards diseased sites. Recently, magnetic nanoflowers showed a remarkable heating performance in hyperthermia experiments thanks to their complex structure leading to a broad range of magnetic dynamics. To grasp their full potential and to better understand the origin of this unexpected heating performance, we propose the use of Kaczmarz' algorithm in interpreting magnetic characterisation measurements. It has the advantage that no a priori assumptions need to be made on the particle size distribution, contrasting current magnetic interpretation methods that often assume a lognormal size distribution. Both approaches are compared on DC magnetometry, magnetorelaxometry and AC susceptibility characterisation measurements of the nanoflowers. We report that the lognormal distribution parameters vary significantly between data sets, whereas Kaczmarz' approach achieves a consistent and accurate characterisation for all measurement sets. Additionally, we introduce a methodology to use Kaczmarz' approach on distinct measurement data sets simultaneously. It has the advantage that the strengths of the individual characterisation techniques are combined and their weaknesses reduced, further improving characterisation accuracy. Our findings are important for biomedical applications as Kaczmarz' algorithm allows to pinpoint multiple, smaller peaks in the nanostructure's size distribution compared to the monomodal lognormal distribution. The smaller peaks permit to fine-tune biomedical applications with respect to these peaks to e.g. boost heating or to reduce blurring effects in images. Furthermore, the Kaczmarz algorithm allows for a standardised data analysis for a broad range of magnetic nanoparticle samples. Thus, our approach can improve the safety and efficiency of biomedical applications of magnetic nanoparticles, paving the way towards their clinical use.
Collapse
Affiliation(s)
| | - Annelies Coene
- Department of Electromechanical, Systems and Metal Engineering, Ghent University Zwijnaarde Belgium
- Cancer Research Institute Ghent Ghent Belgium
| | - Philipp Bender
- Department of Physics and Materials Science, University of Luxembourg Luxembourg Grand Duchy of Luxembourg
| | | |
Collapse
|
4
|
Próspero AG, Soares GA, Moretto GM, Quini CC, Bakuzis AF, de Arruda Miranda JR. Dynamic cerebral perfusion parameters and magnetic nanoparticle accumulation assessed by AC biosusceptometry. BIOMED ENG-BIOMED TE 2020; 65:343-351. [PMID: 31714878 DOI: 10.1515/bmt-2019-0089] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 08/30/2019] [Indexed: 01/25/2023]
Abstract
Cerebral blood flow (CBF) assessment is mainly performed by scintigraphy, computed tomography (CT) and magnetic resonance imaging (MRI). New approaches to assess the CBF through the passage of magnetic nanoparticles (MNPs) to blood-brain barrier (BBB) are convenient to help decrease the use of ionizing radiation and unleash the required MRI schedule in clinics. The development of nanomedicine and new biomedical devices, such as the magnetic particle imaging (MPI), enabled new approaches to study dynamic brain blood flow. In this paper, we employed MNPs and the alternating current biosusceptometry (ACB) to study the brain perfusion. We utilized the mannitol, before the MNPs, injection to modulate the BBB permeability and study its effects on the circulation time of the MNPs in the brain of rats. Also, we characterized a new ACB sensor to increase the systems' applicability to study the MNPs' accumulation, especially in the animals' brain. Our data showed that the injection of mannitol increased the circulation time of MNPs in the brain. Also, the mannitol increased the accumulation of MNPs in the brain. This paper suggests the use of the ACB as a tool to study brain perfusion and accumulation of MNPs in studies of new nano agents focused on the brain diagnostics and treatment.
Collapse
Affiliation(s)
- André Gonçalves Próspero
- Department of Physics and Biophysics, UNESP, São Paulo State University, Biosciences Institute of Botucatu, Prof. Antonio Celso Wagner Zanin Street, 18618-689 Botucatu, Brazil
| | - Guilherme Augusto Soares
- Department of Physics and Biophysics, UNESP, São Paulo State University, Biosciences Institute of Botucatu, Botucatu, Brazil
| | - Gustavo Morlin Moretto
- Department of Physics and Biophysics, UNESP, São Paulo State University, Biosciences Institute of Botucatu, Botucatu, Brazil
| | - Caio C Quini
- Department of Physics and Biophysics, UNESP, São Paulo State University, Biosciences Institute of Botucatu, Botucatu, Brazil
| | | | - José Ricardo de Arruda Miranda
- Department of Physics and Biophysics, UNESP, São Paulo State University, Biosciences Institute of Botucatu, Botucatu, Brazil
| |
Collapse
|
5
|
Soares GA, Prospero AG, Calabresi MF, Rodrigues DS, Simoes LG, Quini CC, Matos RR, Pinto LA, Sousa-Junior AA, Bakuzis AF, Mancera PA, Miranda JRA. Multichannel AC Biosusceptometry System to Map Biodistribution and Assess the Pharmacokinetic Profile of Magnetic Nanoparticles by Imaging. IEEE Trans Nanobioscience 2019; 18:456-462. [PMID: 30998477 DOI: 10.1109/tnb.2019.2912073] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this paper, the application of a technique to evaluate in vivo biodistribution of magnetic nanoparticles (MNP) is addressed: the Multichannel AC Biosusceptometry System (MC-ACB). It allows real-time assessment of magnetic nanoparticles in both bloodstream clearance and liver accumulation, where a complex network of inter-related cells is responsible for MNP uptake. Based on the acquired MC-ACB images, we propose a mathematical model which helps to understand the distribution and accumulation pharmacokinetics of MNP. The MC-ACB showed a high time resolution to detect and monitor MNP, providing sequential images over the particle biodistribution. Utilizing the MC-ACB instrument, we assessed regions corresponding to the heart and liver, and we determined the MNP transfer rates between the bloodstream and the liver. The pharmacokinetic model resulted in having a strong correlation with the experimental data, suggesting that the MC-ACB is a valuable and accessible imaging device to assess in vivo and real-time pharmacokinetic features of MNP.
Collapse
|
6
|
Coene A, Leliaert J, Liebl M, Löwa N, Steinhoff U, Crevecoeur G, Dupré L, Wiekhorst F. Multi-color magnetic nanoparticle imaging using magnetorelaxometry. Phys Med Biol 2017; 62:3139-3157. [PMID: 28165335 DOI: 10.1088/1361-6560/aa5e90] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Magnetorelaxometry (MRX) is a well-known measurement technique which allows the retrieval of magnetic nanoparticle (MNP) characteristics such as size distribution and clustering behavior. This technique also enables the non-invasive reconstruction of the spatial MNP distribution by solving an inverse problem, referred to as MRX imaging. Although MRX allows the imaging of a broad range of MNP types, little research has been done on imaging different MNP types simultaneously. Biomedical applications can benefit significantly from a measurement technique that allows the separation of the resulting measurement signal into its components originating from different MNP types. In this paper, we present a theoretical procedure and experimental validation to show the feasibility of MRX imaging in reconstructing multiple MNP types simultaneously. Because each particle type has its own characteristic MRX signal, it is possible to take this a priori information into account while solving the inverse problem. This way each particle type's signal can be separated and its spatial distribution reconstructed. By assigning a unique color code and intensity to each particle type's signal, an image can be obtained in which each spatial distribution is depicted in the resulting color and with the intensity measuring the amount of particles of that type, hence the name multi-color MNP imaging. The theoretical procedure is validated by reconstructing six phantoms, with different spatial arrangements of multiple MNP types, using MRX imaging. It is observed that MRX imaging easily allows up to four particle types to be separated simultaneously, meaning their quantitative spatial distributions can be obtained.
Collapse
Affiliation(s)
- A Coene
- Department of Electrical Energy, Systems and Automation, Ghent University, 9052 Zwijnaarde, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Ficko BW, Giacometti P, Diamond SG. Extended arrays for nonlinear susceptibility magnitude imaging. ACTA ACUST UNITED AC 2015; 60:457-63. [PMID: 26124044 DOI: 10.1515/bmt-2015-0048] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2015] [Accepted: 06/01/2015] [Indexed: 11/15/2022]
Abstract
This study implements nonlinear susceptibility magnitude imaging (SMI) with multifrequency intermodulation and phase encoding. An imaging grid was constructed of cylindrical wells of 3.5-mm diameter and 4.2-mm height on a hexagonal two-dimensional 61-voxel pattern with 5-mm spacing. Patterns of sample wells were filled with 40-μl volumes of Fe3O4 starch-coated magnetic nanoparticles (mNPs) with a hydrodynamic diameter of 100 nm and a concentration of 25 mg/ml. The imaging hardware was configured with three excitation coils and three detection coils in anticipation that a larger imaging system will have arrays of excitation and detection coils. Hexagonal and bar patterns of mNP were successfully imaged (R2>0.9) at several orientations. This SMI demonstration extends our prior work to feature a larger coil array, enlarged field-of-view, effective phase encoding scheme, reduced mNP sample size, and more complex imaging patterns to test the feasibility of extending the method beyond the pilot scale. The results presented in this study show that nonlinear SMI holds promise for further development into a practical imaging system for medical applications.
Collapse
|