1
|
de Souza TF, Ribeiro AO. The impact of the extended π-conjugation in photophysical, photochemical and aggregation behavior of new phthalocyanine–naphthalocyanine hybrids. J Photochem Photobiol A Chem 2017. [DOI: 10.1016/j.jphotochem.2017.02.025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
2
|
Gallez B. Contribution of Harold M. Swartz to In Vivo EPR and EPR Dosimetry. RADIATION PROTECTION DOSIMETRY 2016; 172:16-37. [PMID: 27421469 DOI: 10.1093/rpd/ncw157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In 2015, we are celebrating half a century of research in the application of Electron Paramagnetic Resonance (EPR) as a biodosimetry tool to evaluate the dose received by irradiated people. During the EPR Biodose 2015 meeting, a special session was organized to acknowledge the pioneering contribution of Harold M. (Hal) Swartz in the field. The article summarizes his main contribution in physiology and medicine. Four emerging themes have been pursued continuously along his career since its beginning: (1) radiation biology; (2) oxygen and oxidation; (3) measuring physiology in vivo; and (4) application of these measurements in clinical medicine. The common feature among all these different subjects has been the use of magnetic resonance techniques, especially EPR. In this article, you will find an impressionist portrait of Hal Swartz with the description of the 'making of' this pioneer, a time-line perspective on his career with the creation of three National Institutes of Health-funded EPR centers, a topic-oriented perspective on his career with a description of his major contributions to Science, his role as a mentor and his influence on his academic children, his active role as founder of scientific societies and organizer of scientific meetings, and the well-deserved international recognition received so far.
Collapse
Affiliation(s)
- Bernard Gallez
- Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Avenue Mounier 73.08, B-1200, Brussels, Belgium
| |
Collapse
|
3
|
Palmer J, Potter L, Ahmad R. Optimization of magnetic field sweep and field modulation amplitude for continuous-wave EPR oximetry. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2011; 209:337-340. [PMID: 21334232 PMCID: PMC3086786 DOI: 10.1016/j.jmr.2011.01.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2010] [Revised: 11/22/2010] [Accepted: 01/10/2011] [Indexed: 05/30/2023]
Abstract
For continuous-wave electron paramagnetic resonance spectroscopy, what settings of magnetic field sweep width and field modulation amplitude yield the best accuracy in estimated linewidth? Statistical bounds on estimation error presented in this work provide practical guidance: set the sweep width and modulation amplitude to 8 and 4 times the half-width half-maximum linewidth, Γ, respectively. For unknown linewidths in the range [Γ(min),Γ(max)] the worst-case estimation error is minimized by using settings designed for Γ(max). The analysis assumes a Lorentzian lineshape and a constant modulation amplitude across the extent of the irradiated paramagnetic probe. The analytical guidelines are validated using L-band spectroscopy with a particulate LiNc-BuO probe.
Collapse
Affiliation(s)
- J. Palmer
- Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - L.C. Potter
- Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43210, USA
| | - R. Ahmad
- Center of Biomedical EPR Spectroscopy and Imaging, Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
4
|
Affiliation(s)
- John Mack
- Department of Chemistry, Graduate School of Science, Tohoku University, Sendai, Japan
| | | |
Collapse
|
5
|
Ahmad R, Som S, Kesselring E, Kuppusamy P, Zweier JL, Potter LC. Digital detection and processing of multiple quadrature harmonics for EPR spectroscopy. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 207:322-31. [PMID: 20971667 PMCID: PMC2993834 DOI: 10.1016/j.jmr.2010.09.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2010] [Revised: 09/24/2010] [Accepted: 09/24/2010] [Indexed: 05/12/2023]
Abstract
A quadrature digital receiver and associated signal estimation procedure are reported for L-band electron paramagnetic resonance (EPR) spectroscopy. The approach provides simultaneous acquisition and joint processing of multiple harmonics in both in-phase and out-of-phase channels. The digital receiver, based on a high-speed dual-channel analog-to-digital converter, allows direct digital down-conversion with heterodyne processing using digital capture of the microwave reference signal. Thus, the receiver avoids noise and nonlinearity associated with analog mixers. Also, the architecture allows for low-Q anti-alias filtering and does not require the sampling frequency to be time-locked to the microwave reference. A noise model applicable for arbitrary contributions of oscillator phase noise is presented, and a corresponding maximum-likelihood estimator of unknown parameters is also reported. The signal processing is applicable for Lorentzian lineshape under nonsaturating conditions. The estimation is carried out using a convergent iterative algorithm capable of jointly processing the in-phase and out-of-phase data in the presence of phase noise and unknown microwave phase. Cramér-Rao bound analysis and simulation results demonstrate a significant reduction in linewidth estimation error using quadrature detection, for both low and high values of phase noise. EPR spectroscopic data are also reported for illustration.
Collapse
Affiliation(s)
- R Ahmad
- Center of Biomedical EPR Spectroscopy and Imaging, Davis Heart and Lung Research Institute, Department of Internal Medicine, The Ohio State University, Columbus, OH 43210, USA.
| | | | | | | | | | | |
Collapse
|
6
|
Khan M, Kwiatkowski P, Rivera BK, Kuppusamy P. Oxygen and oxygenation in stem-cell therapy for myocardial infarction. Life Sci 2010; 87:269-74. [PMID: 20600148 DOI: 10.1016/j.lfs.2010.06.013] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2010] [Revised: 06/09/2010] [Accepted: 06/15/2010] [Indexed: 01/15/2023]
Abstract
Myocardial infarction (MI) is caused by deprivation of oxygen and nutrients to the cardiac tissue due to blockade of coronary artery. It is a major contributor to chronic heart disease, a leading cause of mortality in the modern world. Oxygen is required to meet the constant energy demands for heart contractility, and also plays an important role in the regulation of heart function. However, reoxygenation of the ischemic myocardium upon restoration of blood flow may lead to further injury. Controlled oxygen delivery during reperfusion has been advocated to prevent this consequence. Monitoring the myocardial oxygen concentration would play a vital role in understanding the pathological changes in the ischemic heart following myocardial infarction. During the last two decades, several new techniques have become available to monitor myocardial oxygen concentration in vivo. Electron paramagnetic resonance (EPR) oximetry would appear to be the most promising and reliable of these techniques. EPR utilizes crystalline probes which yield a single sharp line, the width of which is highly sensitive to oxygen tension. Decreased oxygen tension results in a sharpening of the EPR spectrum, while an increase results in widening. In our recent studies, we have used EPR oximetry as a valuable tool to monitor myocardial oxygenation for several applications like ischemia-reperfusion injury, stem-cell therapy and hyperbaric oxygen therapy. The results obtained from these studies have demonstrated the importance of tissue oxygen in the application of stem-cell therapy to treat ischemic heart tissues. These results have been summarized in this review article.
Collapse
Affiliation(s)
- Mahmood Khan
- Davis Heart and Lung Research Institute, Division of Cardiovascular Medicine, Department of Internal Medicine, The Ohio State University, Columbus, OH 43210, USA
| | | | | | | |
Collapse
|
7
|
Trivedi ER, Lee S, Zong H, Blumenfeld CM, Barrett AGM, Hoffman BM. Synthesis of Heteroatom Substituted Naphthoporphyrazine Derivatives with Near-Infrared Absorption and Emission. J Org Chem 2010; 75:1799-802. [DOI: 10.1021/jo9026947] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Evan R. Trivedi
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208
| | - Sangwan Lee
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208
| | - Hong Zong
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208
| | - Carl M. Blumenfeld
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208
| | - Anthony G. M. Barrett
- Department of Chemistry, Imperial College of Science, Technology and Medicine, South Kensington, London, United Kingdom
| | - Brian M. Hoffman
- Department of Chemistry, Northwestern University, Evanston, Illinois 60208
| |
Collapse
|
8
|
Eteshola E, Pandian RP, Lee SC, Kuppusamy P. Polymer coating of paramagnetic particulates for in vivo oxygen-sensing applications. Biomed Microdevices 2009; 11:379-87. [PMID: 19083100 DOI: 10.1007/s10544-008-9244-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Crystalline lithium phthalocyanine (LiPc) can be used to sense oxygen. To enhance biocompatibility/stability of LiPc, we encapsulated LiPc in Teflon AF (TAF), cellulose acetate (CA), and polyvinyl acetate (PVAc) (TAF, previously used to encapsulate LiPc, was a comparator). We identified water-miscible solvents that don't dissolve LiPc crystals, but are solvents for the polymers, and encapsulated crystals by solvent evaporation. Oxygen sensitivity of films was characterized in vitro and in vivo. Encapsulation did not change LiPc oximetry properties in vitro at anoxic conditions or varying partial pressures of oxygen (pO2). EPR linewidth of encapsulated particles was linear with pO2, responding to pO2 changes quickly and reproducibly for dynamic measurements. Encapsulated LiPc was unaffected by biological oxidoreductants, stable in vivo for four weeks. Oximetry, stability and biocompatibility properties of LiPc films were comparable, but both CA and PVAc films are cheaper, and easier to fabricate and handle than TAF films, making them superior.
Collapse
Affiliation(s)
- Edward Eteshola
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH 43210, USA
| | | | | | | |
Collapse
|
9
|
Vikram DS, Ahmad R, Pandian RP, Petryakov S, Kuppusamy P. Evaluation of oxygen-response times of phthalocyanine-based crystalline paramagnetic spin probes for EPR oximetry. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2008; 193:127-132. [PMID: 18479953 PMCID: PMC2722937 DOI: 10.1016/j.jmr.2008.04.034] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2008] [Revised: 04/09/2008] [Accepted: 04/24/2008] [Indexed: 05/26/2023]
Abstract
The goal of the present study was to evaluate the temporal response of particulate-based EPR oximetry probes to changes in partial pressure of oxygen (pO(2)). In order to accurately evaluate the oxygen-response time, we developed a method for rapid modulation of pO(2) in a chamber containing the probe using an oscillator-driven speaker-diaphragm setup. The apparatus was capable of producing sinusoidal changes in pO(2) at frequencies up to 300 Hz or more. The pressure-modulation setup was used to evaluate the temporal response of some of the most commonly used phthalocyanine-based particulate probes. For validation, the time-response of the probes was compared to that of a high sensitivity pressure sensor. The results revealed that some particulate probes could respond to changes in pO(2) with a temporal response of 3.3 ms (300 Hz). The observations were interpreted in the light of their crystalline packing in favor of oxygen diffusion. The results of the present study should enable the selection of probes for oximetry applications requiring high temporal resolution.
Collapse
|
10
|
Sostaric JZ, Pandian RP, Bratasz A, Kuppusamy P. Encapsulation of a highly sensitive EPR active oxygen probe into sonochemically prepared microspheres. J Phys Chem B 2007; 111:3298-303. [PMID: 17388464 PMCID: PMC2533636 DOI: 10.1021/jp0682356] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
High-power ultrasound (20 kHz) was used to encapsulate a solution of perchlorotriphenylmethyl triester (PTM-TE, a stable organic free radical) dissolved in hexamethyldisiloxane (HMDS) into a polymerized shell of bovine serum albumin (BSA). The size distribution of the microspheres was between 0.5 and 3 microm with a maximum at approximately 1.2 microm. The electron paramagnetic resonance spectrum of PTM-TE consists of a single, sharp line which is sensitive to the surrounding concentration of oxygen. It was found that the technique of encapsulating a solution of PTM-TE dissolved in HMDS into the BSA microspheres resulted in an overall loss of EPR signal intensity from the washed suspension of microspheres. However, the encapsulated PTM-TE/HMDS solution remained sensitive to the partial pressure of oxygen in the surrounding environment. The microspheres were found to be useful for determining the partial pressure of oxygen in the muscle and tumor tissue of mice.
Collapse
Affiliation(s)
| | | | | | - Periannan Kuppusamy
- Corresponding author. Periannan Kuppusamy, Tel: 614-292-8998; Fax: 614-292-8454; E-mail:
| |
Collapse
|
11
|
Pandian RP, Kim YI, Woodward PM, Zweier JL, Manoharan PT, Kuppusamy P. The open molecular framework of paramagnetic lithium octabutoxy-naphthalocyanine: implications for the detection of oxygen and nitric oxide using EPR spectroscopy. ACTA ACUST UNITED AC 2006. [DOI: 10.1039/b517976a] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|