1
|
Zu Z, Lin EC, Louie EA, Xu J, Li H, Xie J, Lankford CL, Chekmenev EY, Swanson SD, Does MD, Gore JC, Gochberg DF. Relayed nuclear Overhauser enhancement sensitivity to membrane Cho phospholipids. Magn Reson Med 2020; 84:1961-1976. [PMID: 32243662 PMCID: PMC8238412 DOI: 10.1002/mrm.28258] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 02/17/2020] [Accepted: 02/26/2020] [Indexed: 12/20/2022]
Abstract
PURPOSE Phospholipids are key constituents of cell membranes and serve vital functions in the regulation of cellular processes; thus, a method for in vivo detection and characterization could be valuable for detecting changes in cell membranes that are consequences of either normal or pathological processes. Here, we describe a new method to map the distribution of partially restricted phospholipids in tissues. METHODS The phospholipids were measured by signal changes caused by relayed nuclear Overhauser enhancement-mediated CEST between the phospholipid Cho headgroup methyl protons and water at around -1.6 ppm from the water resonance. The biophysical basis of this effect was examined by controlled manipulation of head group, chain length, temperature, degree of saturation, and presence of cholesterol. Additional experiments were performed on animal tumor models to evaluate potential applications of this novel signal while correcting for confounding contributions. RESULTS Negative relayed nuclear Overhauser dips in Z-spectra were measured from reconstituted Cho phospholipids with cholesterol but not for other Cho-containing metabolites or proteins. Significant contrast was found between tumor and contralateral normal tissue signals in animals when comparing both the measured saturation transfer signal and a more specific imaging metric. CONCLUSION We demonstrated specific relayed nuclear Overhauser effects in partially restricted phospholipid phantoms and similar effects in solid brain tumors after correcting for confounding signal contributions, suggesting possible translational applications of this novel molecular imaging method, which we name restricted phospholipid transfer.
Collapse
Affiliation(s)
- Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Eugene C. Lin
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Elizabeth A. Louie
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Junzhong Xu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
- Deparment of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee
| | - Hua Li
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
- Deparment of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee
| | - Jingping Xie
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
| | - Christopher L. Lankford
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
| | - Eduard Y. Chekmenev
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee
| | - Scott D. Swanson
- Department of Radiology, University of Michigan, Ann Arbor, Michigan
| | - Mark D. Does
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee
- Department of Electrical Engineering, Vanderbilt University, Nashville, Tennessee
| | - John C. Gore
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
- Deparment of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee
- Department of Molecular Physiology and Biophysics, Vanderbilt University, Nashville, Tennessee
| | - Daniel F. Gochberg
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
- Deparment of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee
| |
Collapse
|
2
|
Kim J, Wu Y, Guo Y, Zheng H, Sun PZ. A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging. CONTRAST MEDIA & MOLECULAR IMAGING 2015; 10:163-178. [PMID: 25641791 DOI: 10.1002/cmmi.1628] [Citation(s) in RCA: 89] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Revised: 08/26/2014] [Accepted: 09/10/2014] [Indexed: 01/10/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is a versatile imaging method that probes the chemical exchange between bulk water and exchangeable protons. CEST imaging indirectly detects dilute labile protons via bulk water signal changes following selective saturation of exchangeable protons, which offers substantial sensitivity enhancement and has sparked numerous biomedical applications. Over the past decade, CEST imaging techniques have rapidly evolved owing to contributions from multiple domains, including the development of CEST mathematical models, innovative contrast agent designs, sensitive data acquisition schemes, efficient field inhomogeneity correction algorithms, and quantitative CEST (qCEST) analysis. The CEST system that underlies the apparent CEST-weighted effect, however, is complex. The experimentally measurable CEST effect depends not only on parameters such as CEST agent concentration, pH and temperature, but also on relaxation rate, magnetic field strength and more importantly, experimental parameters including repetition time, RF irradiation amplitude and scheme, and image readout. Thorough understanding of the underlying CEST system using qCEST analysis may augment the diagnostic capability of conventional imaging. In this review, we provide a concise explanation of CEST acquisition methods and processing algorithms, including their advantages and limitations, for optimization and quantification of CEST MRI experiments.
Collapse
Affiliation(s)
- Jinsuh Kim
- Department of Radiology, University of Iowa, Iowa City, IA, USA
| | - Yin Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Key Laboratory for MRI, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Yingkun Guo
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Key Laboratory for MRI, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| |
Collapse
|
3
|
André M, Dumez JN, Rezig L, Shintu L, Piotto M, Caldarelli S. Complete protocol for slow-spinning high-resolution magic-angle spinning NMR analysis of fragile tissues. Anal Chem 2014; 86:10749-54. [PMID: 25286333 DOI: 10.1021/ac502792u] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
High-resolution magic-angle spinning (HR-MAS) nuclear magnetic resonance (NMR) is an essential tool to characterize a variety of semisolid systems, including biological tissues, with virtually no sample preparation. The "non-destructive" nature of NMR is typically compromised, however, by the extreme centrifugal forces experienced under conventional HR-MAS frequencies of several kilohertz. These features limit the usefulness of current HR-MAS approaches for fragile samples. Here, we introduce a full protocol for acquiring high-quality HR-MAS NMR spectra of biological tissues at low spinning rates (down to a few hundred hertz). The protocol first consists of a carefully designed sample preparation, which yields spectra without significant spinning sidebands at low spinning frequency for several types of sample holders, including the standard disposable inserts classically used in HR-MAS NMR-based metabolomics. Suppression of broad spectral features is then achieved using a modified version of the recently introduced PROJECT experiment with added water suppression and rotor synchronization, which deposits limited power in the sample and which can be suitably rotor-synchronized at low spinning rates. The performance of the slow HR-MAS NMR procedure is demonstrated on conventional (liver tissue) and very delicate (fish eggs) samples, for which the slow-spinning conditions are shown to preserve the structural integrity and to minimize intercompartmental leaks of metabolites. Taken together, these results expand the applicability and reliability of HR-MAS NMR spectroscopy. These results have been obtained at 400 and 600 MHz and suggest that high-quality slow HR-MAS spectra can be expected at higher magnetic fields using the described protocol.
Collapse
Affiliation(s)
- Marion André
- Institut de Chimie des Substances Naturelles, CNRS UPR 2301 , Avenue de la Terrasse, 91190 Gif sur Yvette, France
| | | | | | | | | | | |
Collapse
|
4
|
Scheidegger R, Wong ET, Alsop DC. Contributors to contrast between glioma and brain tissue in chemical exchange saturation transfer sensitive imaging at 3 Tesla. Neuroimage 2014; 99:256-68. [PMID: 24857712 DOI: 10.1016/j.neuroimage.2014.05.036] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2013] [Revised: 04/30/2014] [Accepted: 05/14/2014] [Indexed: 11/26/2022] Open
Abstract
Off-resonance saturation transfer images have shown intriguing differences in intensity in glioma compared to normal brain tissues. Interpretation of these differences is complicated, however, by the presence of multiple sources of exchanging magnetization including amide, amine, and hydroxyl protons, asymmetric magnetization transfer contrast (MTC) from macromolecules, and various protons with resonances in the aliphatic spectral region. We report a study targeted at separating these components and identifying their relative contributions to contrast in glioma. Off-resonance z-spectra at several saturation powers and durations were obtained from 6 healthy controls and 8 patients with high grade glioma. Results indicate that broad macromolecular MTC in normal brain tissue is responsible for the majority of contrast with glioma. Amide exchange could be detected with lower saturation power than has previously been reported in glioma, but it was a weak signal source with no detectable contrast from normal brain tissue. At higher saturation powers, amine proton exchange was a major contributor to the observed signal but showed no significant difference from normal brain. Robust acquisition strategies that effectively isolate the contributions of broad macromolecular MTC asymmetry from amine exchange were demonstrated that may provide improved contrast between glioma and normal tissue.
Collapse
Affiliation(s)
- Rachel Scheidegger
- Harvard-MIT Division of Health Sciences and Technology, 77 Massachusetts Ave E25, Cambridge, MA 02139, USA; Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215, USA.
| | - Eric T Wong
- Brain Tumor Center and Neuro-Oncology Unit, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215, USA; Neurology, Harvard Medical School, Boston, MA 02115, USA.
| | - David C Alsop
- Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215, USA; Radiology, Harvard Medical School, Boston, MA 02115, USA.
| |
Collapse
|
5
|
Renault M, Shintu L, Piotto M, Caldarelli S. Slow-spinning low-sideband HR-MAS NMR spectroscopy: delicate analysis of biological samples. Sci Rep 2013; 3:3349. [PMID: 24284435 PMCID: PMC3842542 DOI: 10.1038/srep03349] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2013] [Accepted: 10/30/2013] [Indexed: 11/18/2022] Open
Abstract
High-Resolution Magic-Angle Spinning (HR-MAS) NMR spectroscopy has become an extremely versatile analytical tool to study heterogeneous systems endowed with liquid-like dynamics. Spinning frequencies of several kHz are however required to obtain NMR spectra, devoid of spinning sidebands, with a resolution approaching that of purely isotropic liquid samples. An important limitation of the method is the large centrifugal forces that can damage the structure of the sample. In this communication, we show that optimizing the sample preparation, particularly avoiding air bubbles, and the geometry of the sample chamber of the HR-MAS rotor leads to high-quality low-sideband NMR spectra even at very moderate spinning frequencies, thus allowing the use of well-established solution-state NMR procedures for the characterization of small and highly dynamic molecules in the most fragile samples, such as live cells and intact tissues.
Collapse
Affiliation(s)
- Marie Renault
- Aix Marseille Université, CNRS, Centrale Marseille, iSm2 UMR 7313, 13397, Marseille, France
| | | | | | | |
Collapse
|
6
|
Zu Z, Janve VA, Xu J, Does MD, Gore JC, Gochberg DF. A new method for detecting exchanging amide protons using chemical exchange rotation transfer. Magn Reson Med 2012; 69:637-47. [PMID: 22505325 DOI: 10.1002/mrm.24284] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2011] [Revised: 03/13/2012] [Accepted: 03/14/2012] [Indexed: 11/08/2022]
Abstract
In this study, we introduce a new method for amide proton transfer imaging based on chemical exchange rotation transfer. It avoids several artifacts that plague conventional chemical exchange saturation transfer approaches by creating label and reference scans based on varying the irradiation pulse rotation angle (π and 2π radians) instead of the frequency offset (3.5 and -3.5 ppm). Specifically, conventional analysis is sensitive to confounding contributions from magnetic field (B(0)) inhomogeneities and, more problematically, inherently asymmetric macromolecular resonances. In addition, the lipid resonance at -3.5 ppm complicates the interpretation of the reference scan and decreases the resulting contrast. Finally, partial overlap of the amide signal by nearby amines and hydroxyls obscure the results. By avoiding these issues, our new method is a promising approach for imaging endogenous protein and peptide content and mapping pH.
Collapse
Affiliation(s)
- Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232-2310, USA
| | | | | | | | | | | |
Collapse
|
7
|
Scheidegger R, Vinogradov E, Alsop DC. Amide proton transfer imaging with improved robustness to magnetic field inhomogeneity and magnetization transfer asymmetry using saturation with frequency alternating RF irradiation. Magn Reson Med 2011; 66:1275-85. [PMID: 21608029 DOI: 10.1002/mrm.22912] [Citation(s) in RCA: 86] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2010] [Revised: 02/01/2011] [Accepted: 02/15/2011] [Indexed: 01/21/2023]
Abstract
Amide proton transfer (APT) imaging has shown promise as an indicator of tissue pH and as a marker for brain tumors. Sources of error in APT measurements include direct water saturation, and magnetization transfer (MT) from membranes and macromolecules. These are typically suppressed by postprocessing asymmetry analysis. However, this approach is strongly dependent on B(0) homogeneity and can introduce additional errors due to intrinsic MT asymmetry, aliphatic proton features opposite the amide peak and radiation damping-induced asymmetry. Although several methods exist to correct for B(0) inhomogeneity, they tremendously increase scan times and do not address errors induced by asymmetry of the z-spectrum. In this article, a novel saturation scheme-saturation with frequency alternating RF irradiation (SAFARI)-is proposed in combination with a new magnetization transfer ratio (MTR) parameter designed to generate APT images insensitive to direct water saturation and MT, even in the presence of B(0) inhomogeneity. The feasibility of the SAFARI technique is demonstrated in phantoms and in the human brain. Experimental results show that SAFARI successfully removes direct water saturation and MT contamination from APT images. It is insensitive to B(0) offsets up to 180 Hz without using additional B(0) correction, thereby dramatically reducing scanning time.
Collapse
Affiliation(s)
- Rachel Scheidegger
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts, USA.
| | | | | |
Collapse
|
8
|
Sun PZ. Simplified and scalable numerical solution for describing multi-pool chemical exchange saturation transfer (CEST) MRI contrast. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 205:235-41. [PMID: 20570196 PMCID: PMC2902598 DOI: 10.1016/j.jmr.2010.05.004] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2010] [Revised: 05/06/2010] [Accepted: 05/06/2010] [Indexed: 05/11/2023]
Abstract
Chemical exchange saturation transfer (CEST) imaging is sensitive to dilute labile proton and microenvironment properties such as pH and temperature, and provides vital information complementary to the conventional MRI methods. Whereas the Bloch equations coupled by exchange terms (i.e., Bloch-McConnell equations) have been utilized to quantify 2-pool CEST contrast, it is tedious to extend the Bloch-McConnell equations to describe CEST contrast beyond four saturation transfer sites. Hence, it is necessary to develop a scalable yet reasonably accurate numerical solution to describe the complex multi-pool CEST contrast. It is postulated here that the multi-pool CEST contrast can be quantified by modifying the classic 2-pool model. Although the direct exchange among labile proton groups is often negligible, labile protons may be coupled indirectly through their interaction with bulk water protons, which has to be quantified. The coupling term was solved empirically, and the proposed simplified solution was shown in good agreement with the conventional simulation. Moreover, the proposed solution is scalable, and can be easily extended to describe multi-pool CEST contrast. In sum, our study established a simplified and scalable, yet reasonably accurate numerical solution, suitable for quantitatively describing multi-pool CEST contrast.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA.
| |
Collapse
|