1
|
Micro-Slab Coil Design for Hyperpolarized Metabolic Flux Analysis in Multiple Samples. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 10:bioengineering10010014. [PMID: 36671586 PMCID: PMC9854444 DOI: 10.3390/bioengineering10010014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 12/06/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022]
Abstract
Abnormal metabolism is a hallmark of cancer cells. Accumulating evidence suggests that metabolic changes are likely to occur before other cellular responses in cancer cells upon drug treatment. Therefore, the metabolic activity or flux in cancer cells could be a potent biomarker for cancer detection and treatment monitoring. Magnetic resonance (MR)-based sensing technologies have been developed with hyperpolarized molecules for real-time flux analysis, but they still suffer from low sensitivity and throughput. To address this limitation, we have developed an innovative miniaturized MR coil, termed micro-slab MR coil, for simultaneous analysis of metabolic flux in multiple samples. Combining this approach with hyperpolarized probes, we were able to quantify the pyruvate-to-lactate flux in two different leukemic cell lines in a non-destructive manner, simultaneously. Further, we were able to rapidly assess flux changes with drug treatment in a single hyperpolarization experiment. This new multi-sample system has the potential to transform our ability to assess metabolic dynamics at scale.
Collapse
|
2
|
Tesfai AS, Fischer J, Özen AC, Eppenberger P, Oehrstroem L, Rühli F, Ludwig U, Bock M. Multi-parameter Analytical Method for B1 and SNR Analysis (MAMBA): An open source RF coil design tool. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 319:106825. [PMID: 32947127 DOI: 10.1016/j.jmr.2020.106825] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 08/05/2020] [Accepted: 09/03/2020] [Indexed: 06/11/2023]
Abstract
In Magnetic Resonance Imaging (MRI), radio frequency (RF) coils of different forms and shapes are used to maximize signal-to-noise ratio (SNR). RF coils are designed for clinical applications and have dimensions comparable with the target body part to be imaged, and they perform best when loaded by human tissue majority of which have conductivity values higher than 0.5 S/m. However, they are not properly tuned and matched for samples having low conductivity such as solid samples with low water content. Moreover, for samples with low filling factor and low conductivity, the noise in MRI is dominated by RF coil losses. In this case, RF coil design can be optimized to improve image SNR. Here, a new software tool (Multi-parameter Analytical Method for B1 and SNR Analysis) MAMBA is presented to design and compare volume coils of birdcage, solenoid, and loop-gap design for these samples. The input parameters of the tool are the sample properties, the coil design and the hardware properties, of which a relative SNR is determined. For that, a figure of merit is calculated from the coil sensitivity, applied resonant frequency and the resistive losses of sample, coil and capacitive components. The tool was tested in an ancient Egyptian mummy head which represents an extreme case of MRI with short T2*. Two optimized birdcage coils were designed using MAMBA, constructed and compared to a commercial transmit receive head coil. Calculated relative SNR values are in good agreement with the measurements.
Collapse
Affiliation(s)
- Agazi Samuel Tesfai
- Dept. of Radiology, Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | - Johannes Fischer
- Dept. of Radiology, Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ali Caglar Özen
- Dept. of Radiology, Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; German Consortium for Translational Cancer Research Partner Site Freiburg, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Patrick Eppenberger
- Institute of Evolutionary Medicine, Faculty of Medicine, University of Zurich, Switzerland
| | - Lena Oehrstroem
- Institute of Evolutionary Medicine, Faculty of Medicine, University of Zurich, Switzerland
| | - Frank Rühli
- Institute of Evolutionary Medicine, Faculty of Medicine, University of Zurich, Switzerland
| | - Ute Ludwig
- Dept. of Radiology, Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Michael Bock
- Dept. of Radiology, Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
3
|
Moussu MAC, Ciobanu L, Kurdjumov S, Nenasheva E, Djemai B, Dubois M, Webb AG, Enoch S, Belov P, Abdeddaim R, Glybovski S. Systematic Analysis of the Improvements in Magnetic Resonance Microscopy with Ferroelectric Composite Ceramics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1900912. [PMID: 31099950 DOI: 10.1002/adma.201900912] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 04/29/2019] [Indexed: 06/09/2023]
Abstract
The spatial resolution and signal-to-noise ratio (SNR) attainable in magnetic resonance microscopy (MRM) are limited by intrinsic probe losses and probe-sample interactions. In this work, the possibility to exceed the SNR of a standard solenoid coil by more than a factor-of-two is demonstrated theoretically and experimentally. This improvement is achieved by exciting the first transverse electric mode of a low-loss ceramic resonator instead of using the quasi-static field of the metal-wire solenoid coil. Based on theoretical considerations, a new probe for microscopy at 17 T is developed as a dielectric ring resonator made of ferroelectric/dielectric low-loss composite ceramics precisely tunable via temperature control. Besides the twofold increase in SNR, compared with the solenoid probe, the proposed ceramic probe does not cause static-field inhomogeneity and related image distortion.
Collapse
Affiliation(s)
- Marine A C Moussu
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France
- Multiwave Innovation SAS, 13453, Marseille, France
| | - Luisa Ciobanu
- DRF/I2BM/Neurospin/UNIRS, 91191, Gif-sur-Yvette Cedex, France
| | | | | | - Boucif Djemai
- DRF/I2BM/Neurospin/UNIRS, 91191, Gif-sur-Yvette Cedex, France
| | - Marc Dubois
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France
| | - Andrew G Webb
- Department of Radiology, C.J. Gorter Center for High Field MRI, Leiden University Medical Center, 2333 ZA, Leiden, The Netherlands
| | - Stefan Enoch
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France
| | - Pavel Belov
- ITMO University, 197101, St. Petersburg, Russia
| | - Redha Abdeddaim
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, 13013, Marseille, France
| | | |
Collapse
|
4
|
Spengler N, Höfflin J, Moazenzadeh A, Mager D, MacKinnon N, Badilita V, Wallrabe U, Korvink JG. Heteronuclear Micro-Helmholtz Coil Facilitates µm-Range Spatial and Sub-Hz Spectral Resolution NMR of nL-Volume Samples on Customisable Microfluidic Chips. PLoS One 2016; 11:e0146384. [PMID: 26730968 PMCID: PMC4701473 DOI: 10.1371/journal.pone.0146384] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2015] [Accepted: 12/16/2015] [Indexed: 11/25/2022] Open
Abstract
We present a completely revised generation of a modular micro-NMR detector, featuring an active sample volume of ∼ 100 nL, and an improvement of 87% in probe efficiency. The detector is capable of rapidly screening different samples using exchangeable, application-specific, MEMS-fabricated, microfluidic sample containers. In contrast to our previous design, the sample holder chips can be simply sealed with adhesive tape, with excellent adhesion due to the smooth surfaces surrounding the fluidic ports, and so withstand pressures of ∼2.5 bar, while simultaneously enabling high spectral resolution up to 0.62 Hz for H2O, due to its optimised geometry. We have additionally reworked the coil design and fabrication processes, replacing liquid photoresists by dry film stock, whose final thickness does not depend on accurate volume dispensing or precise levelling during curing. We further introduced mechanical alignment structures to avoid time-intensive optical alignment of the chip stacks during assembly, while we exchanged the laser-cut, PMMA spacers by diced glass spacers, which are not susceptible to melting during cutting. Doing so led to an overall simplification of the entire fabrication chain, while simultaneously increasing the yield, due to an improved uniformity of thickness of the individual layers, and in addition, due to more accurate vertical positioning of the wirebonded coils, now delimited by a post base plateau. We demonstrate the capability of the design by acquiring a 1H spectrum of ∼ 11 nmol sucrose dissolved in D2O, where we achieved a linewidth of 1.25 Hz for the TSP reference peak. Chemical shift imaging experiments were further recorded from voxel volumes of only ∼ 1.5 nL, which corresponded to amounts of just 1.5 nmol per voxel for a 1 M concentration. To extend the micro-detector to other nuclei of interest, we have implemented a trap circuit, enabling heteronuclear spectroscopy, demonstrated by two 1H/13C 2D HSQC experiments.
Collapse
Affiliation(s)
- Nils Spengler
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen, Germany
- Freiburg Institute for Advanced Studies (FRIAS), University of Freiburg, Freiburg, Germany
| | - Jens Höfflin
- Laboratory of Simulation, IMTEK–Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
| | - Ali Moazenzadeh
- Laboratory for Microactuators, IMTEK–Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
| | - Dario Mager
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen, Germany
| | - Neil MacKinnon
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen, Germany
| | - Vlad Badilita
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen, Germany
| | - Ulrike Wallrabe
- Laboratory for Microactuators, IMTEK–Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
| | - Jan G. Korvink
- Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen, Germany
- Freiburg Institute for Advanced Studies (FRIAS), University of Freiburg, Freiburg, Germany
| |
Collapse
|
5
|
Zalesskiy SS, Danieli E, Blümich B, Ananikov VP. Miniaturization of NMR systems: desktop spectrometers, microcoil spectroscopy, and "NMR on a chip" for chemistry, biochemistry, and industry. Chem Rev 2014; 114:5641-94. [PMID: 24779750 DOI: 10.1021/cr400063g] [Citation(s) in RCA: 129] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Sergey S Zalesskiy
- Zelinsky Institute of Organic Chemistry, Russian Academy of Sciences , Moscow, 119991, Russia
| | | | | | | |
Collapse
|
6
|
Zhivonitko VV, Telkki VV, Leppäniemi J, Scotti G, Franssila S, Koptyug IV. Remote detection NMR imaging of gas phase hydrogenation in microfluidic chips. LAB ON A CHIP 2013; 13:1554-1561. [PMID: 23435499 DOI: 10.1039/c3lc41309h] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The heterogeneous hydrogenation reaction of propene into propane in microreactors is studied by remote detection (RD) nuclear magnetic resonance (NMR). The reactors consist of 36 parallel microchannels (50 × 50 μm(2) cross sections) coated with a platinum catalyst. We show that RD NMR is capable of monitoring reactions with sub-millimeter spatial resolution over a field-of-view of 30 × 8 mm(2) with a steady-state time-of-flight time resolution in the tens of milliseconds range. The method enables the visualization of active zones in the reactors, and time-of-flight is used to image the flow velocity variations inside the reactor. The overall reaction yields determined by NMR varied from 10% to 50%, depending on the flow rate, temperature and length of the reaction channels. The reaction yield was highest for the channels with the lowest flow velocity. Propane T1 relaxation time in the channels, estimated by means of RD NMR images, was 270 ± 18 ms. No parahydrogen-induced polarization (PHIP) was observed in experiments carried out using parahydrogen-enriched H2, indicating fast spreading of the hydrogen atoms on the sputtered Pt surface. In spite of the low concentration of gases, RD NMR made imaging of gas phase hydrogenation of propene in microreactors feasible, and it is a highly versatile method for characterizing on-chip chemical reactions.
Collapse
Affiliation(s)
- Vladimir V Zhivonitko
- Laboratory of Magnetic Resonance Microimaging, International Tomography Center SB RAS, 3A Institutskaya St., Novosibirsk 630090, Russia.
| | | | | | | | | | | |
Collapse
|
7
|
Microfabricated inserts for magic angle coil spinning (MACS) wireless NMR spectroscopy. PLoS One 2012; 7:e42848. [PMID: 22936994 PMCID: PMC3423418 DOI: 10.1371/journal.pone.0042848] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2012] [Accepted: 07/12/2012] [Indexed: 11/19/2022] Open
Abstract
This article describes the development and testing of the first automatically microfabricated probes to be used in conjunction with the magic angle coil spinning (MACS) NMR technique. NMR spectroscopy is a versatile technique for a large range of applications, but its intrinsically low sensitivity poses significant difficulties in analyzing mass- and volume-limited samples. The combination of microfabrication technology and MACS addresses several well-known NMR issues in a concerted manner for the first time: (i) reproducible wafer-scale fabrication of the first-in-kind on-chip LC microresonator for inductive coupling of the NMR signal and reliable exploitation of MACS capabilities; (ii) improving the sensitivity and the spectral resolution by simultaneous spinning the detection microcoil together with the sample at the “magic angle” of 54.74° with respect to the direction of the magnetic field (magic angle spinning – MAS), accompanied by the wireless signal transmission between the microcoil and the primary circuit of the NMR spectrometer; (iii) given the high spinning rates (tens of kHz) involved in the MAS methodology, the microfabricated inserts exhibit a clear kinematic advantage over their previously demonstrated counterparts due to the inherent capability to produce small radius cylindrical geometries, thus tremendously reducing the mechanical stress and tearing forces on the sample. In order to demonstrate the versatility of the microfabrication technology, we have designed MACS probes for various Larmor frequencies (194, 500 and 700 MHz) testing several samples such as water, Drosophila pupae, adamantane solid and LiCl at different magic angle spinning speeds.
Collapse
|
8
|
Même S, Joudiou N, Szeremeta F, Mispelter J, Louat F, Decoville M, Locker D, Beloeil JC. In vivo magnetic resonance microscopy of Drosophilae at 9.4 T. Magn Reson Imaging 2012; 31:109-19. [PMID: 22898691 DOI: 10.1016/j.mri.2012.06.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2012] [Revised: 05/16/2012] [Accepted: 06/25/2012] [Indexed: 10/28/2022]
Abstract
In preclinical research, genetic studies have made considerable progress as a result of the development of transgenic animal models of human diseases. Consequently, there is now a need for higher resolution MRI to provide finer details for studies of small animals (rats, mice) or very small animals (insects). One way to address this issue is to work with high-magnetic-field spectrometers (dedicated to small animal imaging) with strong magnetic field gradients. It is also necessary to develop a complete methodology (transmit/receive coil, pulse sequence, fixing system, air supply, anesthesia capabilities, etc.). In this study, we developed noninvasive protocols, both in vitro and in vivo (from coil construction to image generation), for drosophila MRI at 9.4 T. The 10 10 80-μm resolution makes it possible to visualize whole drosophila (head, thorax, abdomen) and internal organs (ovaries, longitudinal and transverse muscles, bowel, proboscis, antennae and optical lobes). We also provide some results obtained with a Drosophila model of muscle degeneration. This opens the way for new applications of structural genetic modification studies using MRI of drosophila.
Collapse
Affiliation(s)
- Sandra Même
- Centre de Biophysique Moléculaire, CNRS UPR4301, Orléans, France.
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Ryan H, Song SH, Zaß A, Korvink J, Utz M. Contactless NMR Spectroscopy on a Chip. Anal Chem 2012; 84:3696-702. [DOI: 10.1021/ac300204z] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Herbert Ryan
- Department
of Mechanical and Aeropspace Engineering, University of Virginia, Charlottesville, Virginia 22904, United
States
| | - Suk-Heung Song
- Department
of Mechanical and Aeropspace Engineering, University of Virginia, Charlottesville, Virginia 22904, United
States
| | - Anja Zaß
- Department of Microsystems
Engineering, University of Freiburg, Germany
| | - Jan Korvink
- Department of Microsystems
Engineering, University of Freiburg, Germany
- Freiburg Institute for Advanced Studies, Germany
| | - Marcel Utz
- Department
of Mechanical and Aeropspace Engineering, University of Virginia, Charlottesville, Virginia 22904, United
States
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United
States
- Center For Microsystems
For The Life Sciences, University of Virginia, Charlottesville, Virginia 22904, United States
| |
Collapse
|
10
|
Baxan N, Kahlert U, Maciaczyk J, Nikkhah G, Hennig J, von Elverfeldt D. Microcoil-based MR phase imaging and manganese enhanced microscopy of glial tumor neurospheres with direct optical correlation. Magn Reson Med 2011; 68:86-97. [PMID: 22127877 DOI: 10.1002/mrm.23208] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2010] [Revised: 07/06/2011] [Accepted: 08/16/2011] [Indexed: 12/22/2022]
Abstract
Susceptibility differences among tissues were recently used for highlighting complementary contrast in MRI different from the conventional T(1), T(2), or spin density contrasts. This method, based on the signal phase, previously showed improved image contrast of human or rodent neuroarchitecture in vivo, although direct MR phase imaging of cellular architecture was not available until recently. In this study, we present for the first time the ability of microcoil-based phase MRI to resolve the structure of human glioma neurospheres at significantly improved resolutions (10 × 10 μm(2)) with direct optical image correlation. The manganese chloride property to function as a T(1) contrast agent enabled a closer examination of cell physiology with MRI. Specifically the temporal changes of manganese chloride uptake, retention and release time within and from individual clusters were assessed. The optimal manganese chloride concentration for improved MR signal enhancement was determined while keeping the cellular viability unaffected. The presented results demonstrate the possibilities to reveal structural and functional observation of living glioblastoma human-derived cells. This was achieved through the combination of highly sensitive microcoils, high magnetic field, and methods designed to maximize contrast to noise ratio. The presented approach may provide a powerful multimodal tool that merges structural and functional information of submilimeter biological samples.
Collapse
Affiliation(s)
- Nicoleta Baxan
- Department of Radiology, Medical Physics, University Medical Center, Freiburg, Germany.
| | | | | | | | | | | |
Collapse
|