1
|
Price BD, Sojka A, Maity S, Chavez IM, Starck M, Wilson MZ, Han S, Sherwin MS. Field-domain rapid-scan EPR at 240GHz for studies of protein functional dynamics at room temperature. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2024; 366:107744. [PMID: 39096714 DOI: 10.1016/j.jmr.2024.107744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 07/22/2024] [Accepted: 07/24/2024] [Indexed: 08/05/2024]
Abstract
We present field-domain rapid-scan (RS) electron paramagnetic resonance (EPR) at 8.6T and 240GHz. To enable this technique, we upgraded a home-built EPR spectrometer with an FPGA-enabled digitizer and real-time processing software. The software leverages the Hilbert transform to recover the in-phase (I) and quadrature (Q) channels, and therefore the raw absorptive and dispersive signals, χ' and χ'', from their combined magnitude (I2+Q2). Averaging a magnitude is simpler than real-time coherent averaging and has the added benefit of permitting long-timescale signal averaging (up to at least 2.5×106 scans) because it eliminates the effects of source-receiver phase drift. Our rapid-scan (RS) EPR provides a signal-to-noise ratio that is approximately twice that of continuous wave (CW) EPR under the same experimental conditions, after scaling by the square root of acquisition time. We apply our RS EPR as an extension of the recently reported time-resolved Gd-Gd EPR (TiGGER) [Maity et al., 2023], which is able to monitor inter-residue distance changes during the photocycle of a photoresponsive protein through changes in the Gd-Gd dipolar couplings. RS, opposed to CW, returns field-swept spectra as a function of time with 10ms time resolution, and thus, adds a second dimension to the static field transients recorded by TiGGER. We were able to use RS TiGGER to track time-dependent and temperature-dependent kinetics of AsLOV2, a light-activated phototropin domain found in oats. The results presented here combine the benefits of RS EPR with the improved spectral resolution and sensitivity of Gd chelates at high magnetic fields. In the future, field-domain RS EPR at high magnetic fields may enable studies of other real-time kinetic processes with time resolutions that are otherwise difficult to access in the solution state.
Collapse
Affiliation(s)
- Brad D Price
- Department of Physics, University of California, Santa Barbara, 93106, CA, USA; Institute for Terahertz Science and Technology, University of California, Santa Barbara, 93106, CA, USA.
| | - Antonín Sojka
- Department of Physics, University of California, Santa Barbara, 93106, CA, USA; Institute for Terahertz Science and Technology, University of California, Santa Barbara, 93106, CA, USA
| | - Shiny Maity
- Department of Chemistry, University of California, Santa Barbara, 93106, CA, USA; Department of Chemistry, Northwestern University, 633 Clark Street, Evanston, 60208, IL, USA
| | - I Marcelo Chavez
- Department of Chemistry, University of California, Santa Barbara, 93106, CA, USA
| | - Matthieu Starck
- Department of Chemistry, Durham University, Durham, DH13LE, UK
| | - Maxwell Z Wilson
- Department Molecular, Cellular, and Developmental Biology, University of California, Santa Barbara, 93106, CA, USA
| | - Songi Han
- Department of Chemistry, University of California, Santa Barbara, 93106, CA, USA; Department of Chemistry, Northwestern University, 633 Clark Street, Evanston, 60208, IL, USA
| | - Mark S Sherwin
- Department of Physics, University of California, Santa Barbara, 93106, CA, USA; Institute for Terahertz Science and Technology, University of California, Santa Barbara, 93106, CA, USA.
| |
Collapse
|
2
|
Johannsen F, Williams L, Chak MH, Drescher M. Real-Time Monitoring of Photoinduced pH Jumps by In Situ Rapid-Scan EPR Spectroscopy. J Phys Chem Lett 2024; 15:7069-7074. [PMID: 38950357 PMCID: PMC11247492 DOI: 10.1021/acs.jpclett.4c00564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/03/2024]
Abstract
This work represents the first demonstration of monitoring kinetics upon a light-induced pH jump by in situ rapid-scan (RS) electron paramagnetic resonance (EPR) spectroscopy on the millisecond time scale. Here, we focus on the protonation state of an imidazolidine type radical as a pH sensor under visible light irradiation of a merocyanine photoacid in bulk solution. The results highlight the utility of photoacids in combination with pH-sensitive spin probes as an effective tool for the real-time investigation of biochemical mechanisms regulated by changes in the pH value.
Collapse
Affiliation(s)
- Florian Johannsen
- Department of Chemistry and Konstanz Research School Chemical Biology, University of Konstanz, Universitätstraße 10, 78464 Konstanz, Germany
| | - Lara Williams
- Department of Chemistry and Konstanz Research School Chemical Biology, University of Konstanz, Universitätstraße 10, 78464 Konstanz, Germany
| | - Man Him Chak
- School of Chemistry, UNSW Sydney, Sydney, NSW 2052, Australia
| | - Malte Drescher
- Department of Chemistry and Konstanz Research School Chemical Biology, University of Konstanz, Universitätstraße 10, 78464 Konstanz, Germany
| |
Collapse
|
3
|
Sarvari S, McGee D, O'Connell R, Tseytlin O, Bobko AA, Tseytlin M. Electron Spin Resonance Probe Incorporation into Bioinks Permits Longitudinal Oxygen Imaging of Bioprinted Constructs. Mol Imaging Biol 2024; 26:511-524. [PMID: 38038860 PMCID: PMC11211156 DOI: 10.1007/s11307-023-01871-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 10/27/2023] [Accepted: 10/30/2023] [Indexed: 12/02/2023]
Abstract
PURPOSE Bioprinting is an additive manufacturing technology analogous to 3D printing. Instead of plastic or resin, cell-laden hydrogels are used to produce a construct of the intended biological structure. Over time, cells transform this construct into a functioning tissue or organ. The process of printing followed by tissue maturation is referred to as 4D bioprinting. The fourth dimension is temporal. Failure to provide living cells with sufficient amounts of oxygen at any point along the developmental timeline may jeopardize the bioprinting goals. Even transient hypoxia may alter cells' differentiation and proliferation or trigger apoptosis. Electron paramagnetic resonance (EPR) imaging modality is proposed to permit 4D monitoring of oxygen within bioprinted structures. PROCEDURES Lithium octa-n-butoxy-phthalocyanine (LiNc-BuO) probes have been introduced into gelatin methacrylate (GelMA) bioink. GelMA is a cross-linkable hydrogel, and LiNc-BuO is an oxygen-sensitive compound that permits longitudinal oximetric measurements. The effects of the oxygen probe on printability have been evaluated. A digital light processing (DLP) bioprinter was built in the laboratory. Bioprinting protocols have been developed that consider the optical properties of the GelMA/LiNc-BuO composites. Acellular and cell-laden constructs have been printed and imaged. The post-printing effect of residual photoinitiator on oxygen depletion has been investigated. RESULTS Models have been successfully printed using a lab-built bioprinter. Rapid scan EPR images reflective of the expected oxygen concentration levels have been acquired. An unreported problem of oxygen depletion in bioprinted constructs by the residual photoinitiator has been documented. EPR imaging is proposed as a control method for its removal. The oxygen consumption rates by HEK293T cells within a bioprinted cylinder have been imaged and quantified. CONCLUSIONS The feasibility of the cointegration of 4D EPR imaging and 4D bioprinting has been demonstrated. The proof-of-concept experiments, which were conducted using oxygen probes loaded into GelMA, lay the foundation for a broad range of applications, such as bioprinting with many types of bioinks loaded with diverse varieties of molecular spin probes.
Collapse
Affiliation(s)
- Sajad Sarvari
- Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, Morgantown, WV, USA
- In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV, USA
| | - Duncan McGee
- Department of Chemical and Biomedical Engineering, West Virginia University, Morgantown, WV, USA
| | - Ryan O'Connell
- In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV, USA
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV, USA
| | - Oxana Tseytlin
- In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV, USA
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV, USA
| | - Andrey A Bobko
- In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV, USA
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV, USA
| | - Mark Tseytlin
- In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV, USA.
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV, USA.
- West Virginia University Cancer Institute, Morgantown, WV, USA.
| |
Collapse
|
4
|
Sojka A, Price BD, Sherwin MS. Order-of-magnitude SNR improvement for high-field EPR spectrometers via 3D printed quasi-optical sample holders. SCIENCE ADVANCES 2023; 9:eadi7412. [PMID: 37729398 PMCID: PMC10511183 DOI: 10.1126/sciadv.adi7412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 08/18/2023] [Indexed: 09/22/2023]
Abstract
Here, we present a rapidly prototyped, cost-efficient, and 3D printed quasi-optical sample holder for improving the signal-to-noise ratio (SNR) in modern, resonator-free, and high-field electron paramagnetic resonance (HFEPR) spectrometers. Such spectrometers typically operate in induction mode: The detected EPR ("cross-polar") signal is polarized orthogonal to the incident ("co-polar") radiation. The sample holder makes use of an adjustable sample positioner that allows for optimizing the sample position to maximize the 240-gigahertz magnetic field B1 and a rooftop mirror that allows for small rotations of the microwave polarization to maximize the cross-polar signal and minimize the co-polar background. When optimally tuned, the sample holder was able to improve co-polar isolation by ≳20 decibels, which is proven beneficial for maximizing the SNR in rapid-scan, pulsed, and continuous-wave EPR experiments. In rapid-scan mode, the improved SNR enabled the recording of entire EPR spectra of a narrow-line radical in millisecond time scales, which, in turn, enabled real-time monitoring of a sample's evolving line shape.
Collapse
Affiliation(s)
- Antonín Sojka
- Department of Physics, University of California, Santa Barbara, Santa Barbara, CA, USA
- Institute for Terahertz Science and Technology, University of California, Santa Barbara, Santa Barbara, CA 93106, USA
| | - Brad D. Price
- Department of Physics, University of California, Santa Barbara, Santa Barbara, CA, USA
- Institute for Terahertz Science and Technology, University of California, Santa Barbara, Santa Barbara, CA 93106, USA
| | - Mark S. Sherwin
- Department of Physics, University of California, Santa Barbara, Santa Barbara, CA, USA
- Institute for Terahertz Science and Technology, University of California, Santa Barbara, Santa Barbara, CA 93106, USA
| |
Collapse
|
5
|
O'Connell RC, Tseytlin O, Bobko AA, Eubank TD, Tseytlin M. Rapid scan EPR: Automated digital resonator control for low-latency data acquisition. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 345:107308. [PMID: 36356489 PMCID: PMC10266206 DOI: 10.1016/j.jmr.2022.107308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 10/05/2022] [Accepted: 10/06/2022] [Indexed: 06/05/2023]
Abstract
Automation has become an essential component of modern scientific instruments which often capture large amounts of complex dynamic data. Algorithms are developed to read multiple sensors in parallel with data acquisition and to adjust instrumental parameters on the fly. Decisions are made on a time scale unattainable to the human operator. In addition to speed, automation reduces human error, improves the reproducibility of experiments, and improves the reliability of acquired data. An automatic digital control (ADiC) was developed to reliably sustain critical coupling of a resonator over a wide range of time-varying loading conditions. The ADiC uses the computational power of a microcontroller that directly communicates with all system components independent of a personal computer (PC). The PC initiates resonator tuning and coupling by sending a command to MC via serial port. After receiving the command, ADiC establishes critical coupling conditions within approximately 5 ms. A printed circuit board resonator was designed to permit digital control. The performance of the resonator together with the ADiC was evaluated by varying the resonator loading from empty to heavily loaded. For the loading, samples containing aqueous sodium chloride that strongly absorb electromagnetic waves were used. A previously reported rapid scan (RS) electron paramagnetic resonance (EPR) imaging instrument was upgraded by the incorporation of ADiC. RS spectra and an in vivo image of oxygen in a mouse tumor model have been acquired using the upgraded system. ADiC robustly sustained critical coupling of the resonator to the transmission line during these measurements. The design implemented in this study can be used in slow-scan and pulsed EPR with modifications.
Collapse
Affiliation(s)
- Ryan C O'Connell
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA
| | - Oxana Tseytlin
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA
| | - Andrey A Bobko
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA
| | - Timothy D Eubank
- In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA; Department of Microbiology, Immunology and Cell Biology, West Virginia University, Morgantown, WV 26506, USA
| | - Mark Tseytlin
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; West Virginia University Cancer Institute, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA.
| |
Collapse
|
6
|
Eaton GR, Eaton SS. Advances in rapid scan EPR spectroscopy. Methods Enzymol 2022; 666:1-24. [PMID: 35465917 PMCID: PMC10093151 DOI: 10.1016/bs.mie.2022.02.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Progress has been made in hardware for low frequencies, demonstrations of rapid frequency scans, hybrid instrumentation, and improved deconvolution software. The recent availability of the commercial Bruker BioSpin rapid scan accessory for their X-band EMX and Elexsys systems makes this technique available to a wide range of users without the need to construct their own system. Developments at lower frequencies are underway in several labs with the goal of facilitating in vivo and preclinical rapid scan imaging. Development of new deconvolution algorithms will make data processing more robust. Frequency scans have substantial promise at higher frequencies. New examples of applications show the wide applicability and advantages of rapid scan.
Collapse
Affiliation(s)
- Gareth R Eaton
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO, United States.
| | - Sandra S Eaton
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO, United States
| |
Collapse
|