1
|
Şentürk Z. A Journey from the Drops of Mercury to the Mysterious Shores of the Brain: The 100-Year Adventure of Voltammetry. Crit Rev Anal Chem 2022:1-12. [PMID: 35994268 DOI: 10.1080/10408347.2022.2113760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
Voltammetry, which is at the core of electroanalytical chemistry, is an analytical method that investigates and evaluates the current-potential relationship obtained at a given working electrode. If it is used dropping mercury as working electrode, the method is called as polarography. The current year 2022 marks the 100th anniversary of the discovery of polarography by Czech Jaroslav Heyrovský. He received the Nobel Prize in Chemistry in 1959 for this discovery and his contribution to the scientific world. A hundred years, within the endless existence of the universe is maybe nothing. A hundred years, in the history of mankind is a line, maybe a short paragraph. But, in science, a hundred years can lead to very significant advances in a field and often to the birth and establishment of an entirely new scientific discipline. Indeed, in the last hundred years, the design and use of new electrochemical devices, depending on the progress in microelectronics and computer technologies, has almost revolutionized voltammetry. Besides these developments, due to the fact that the redox (oxidation/reduction) process is very basic for living organisms; the voltammetry, especially with the beginning of the 21st century, has started to be used as a very powerful tool in neuroscience to solve the mystery of the brain (the basic problems of biomolecules with physiological and genetic importance in brain tissue). This review article is an overview of the 100-year history and fascinating development of voltammetry from Heyrovský to the present.
Collapse
Affiliation(s)
- Zühre Şentürk
- Faculty of Science, Department of Analytical Chemistry, Van Yuzuncu Yil University, Van, Turkey
| |
Collapse
|
2
|
Mintah Churcher NK, Upasham S, Rice P, Bhadsavle S, Prasad S. Development of a flexible, sweat-based neuropeptide Y detection platform. RSC Adv 2020; 10:23173-23186. [PMID: 35520310 PMCID: PMC9054693 DOI: 10.1039/d0ra03729j] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Accepted: 06/05/2020] [Indexed: 12/14/2022] Open
Abstract
Neuropeptide Y (NPY) biomarker levels have a close association with the diagnosis of Major Depression Disorder (MDD) and anxiety disorders. Quantifying NPY in correlation to self-reported symptoms will be an important measure to ensure a relatively uniform diagnosis and help with disease prognosis of these disorders. The work presented is a novel, passive eccrine sweat based, electrochemical detection platform for quantification of NPY biomarker levels. The paper offers a comparison between non-porous and porous sensor platforms using various electrochemical detection techniques. This work uses a novel strategy towards designing an optimal nanobioelectronic interface to measure NPY. The portability aspect of this detection platform is discussed by the demonstration a novel, portable EmStat Pico based electronic platform. The detection limit of the sensor is 10 pg mL−1 and its range is 20–500 pg mL−1. The NPY detection platform is envisioned to be a wearable point-of need monitoring system for management of chronic anxiety disorders and MDD. Novel wearable NPY biomarker tracking system, envisioned to be a chronic anxiety and MDD management platform via self-monitoring.![]()
Collapse
Affiliation(s)
| | - Sayali Upasham
- Department of Bioengineering
- University of Texas at Dallas
- Richardson
- USA
| | - Paul Rice
- Department of Bioengineering
- University of Texas at Dallas
- Richardson
- USA
| | - Serena Bhadsavle
- Department of Bioengineering
- University of Texas at Dallas
- Richardson
- USA
| | - Shalini Prasad
- Department of Bioengineering
- University of Texas at Dallas
- Richardson
- USA
| |
Collapse
|
3
|
Farina D, Alvau MD, Puggioni G, Calia G, Bazzu G, Migheli R, Sechi O, Rocchitta G, Desole MS, Serra PA. Implantable (Bio)sensors as new tools for wireless monitoring of brain neurochemistry in real time. World J Pharmacol 2014; 3:1-17. [DOI: 10.5497/wjp.v3.i1.1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Revised: 05/01/2014] [Accepted: 05/29/2014] [Indexed: 02/06/2023] Open
Abstract
Implantable electrochemical microsensors are characterized by high sensitivity, while amperometric biosensors are very selective in virtue of the biological detecting element. Each sensor, specific for every neurochemical species, is a miniaturized high-technology device resulting from the combination of several factors: electrode material, shielding polymers, applied electrochemical technique, and in the case of biosensors, biological sensing material, stabilizers, and entrapping chemical nets. In this paper, we summarize the available technology for the in vivo electrochemical monitoring of neurotransmitters (dopamine, norepinephrine, serotonin, acetylcholine, and glutamate), bioenergetic substrates (glucose, lactate, and oxygen), neuromodulators (ascorbic acid and nitric oxide), and exogenous molecules such as ethanol. We also describe the most represented biotelemetric technologies in order to wirelessly transmit the signals of the above-listed neurochemicals. Implantable (Bio)sensors, integrated into miniaturized telemetry systems, represent a new generation of analytical tools that could be used for studying the brain’s physiology and pathophysiology and the effects of different drugs (or toxic chemicals such as ethanol) on neurochemical systems.
Collapse
|
4
|
Rocchitta G, Secchi O, Alvau MD, Farina D, Bazzu G, Calia G, Migheli R, Desole MS, O'Neill RD, Serra PA. Simultaneous telemetric monitoring of brain glucose and lactate and motion in freely moving rats. Anal Chem 2013; 85:10282-8. [PMID: 24102201 DOI: 10.1021/ac402071w] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
A new telemetry system for simultaneous detection of extracellular brain glucose and lactate and motion is presented. The device consists of dual-channel, single-supply miniature potentiostat-I/V converter, a microcontroller unit, a signal transmitter, and a miniaturized microvibration sensor. Although based on simple and inexpensive components, the biotelemetry device has been used for accurate transduction of the anodic oxidation currents generated on the surface of implanted glucose and lactate biosensors and animal microvibrations. The device was characterized and validated in vitro before in vivo experiments. The biosensors were implanted in the striatum of freely moving animals and the biotelemetric device was fixed to the animal's head. Physiological and pharmacological stimulations were given in order to induce striatal neural activation and to modify the motor behavior in awake, untethered animals.
Collapse
Affiliation(s)
- Gaia Rocchitta
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari , Viale S. Pietro 43/b, 07100 Sassari, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Li YT, Wickens JR, Huang YL, Pan WHT, Chen FYB, Chen JJJ. Integrated wireless fast-scan cyclic voltammetry recording and electrical stimulation for reward-predictive learning in awake, freely moving rats. J Neural Eng 2013; 10:046007. [PMID: 23770892 DOI: 10.1088/1741-2560/10/4/046007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Fast-scan cyclic voltammetry (FSCV) is commonly used to monitor phasic dopamine release, which is usually performed using tethered recording and for limited types of animal behavior. It is necessary to design a wireless dopamine sensing system for animal behavior experiments. APPROACH This study integrates a wireless FSCV system for monitoring the dopamine signal in the ventral striatum with an electrical stimulator that induces biphasic current to excite dopaminergic neurons in awake freely moving rats. The measured dopamine signals are unidirectionally transmitted from the wireless FSCV module to the host unit. To reduce electrical artifacts, an optocoupler and a separate power are applied to isolate the FSCV system and electrical stimulator, which can be activated by an infrared controller. MAIN RESULTS In the validation test, the wireless backpack system has similar performance in comparison with a conventional wired system and it does not significantly affect the locomotor activity of the rat. In the cocaine administration test, the maximum electrically elicited dopamine signals increased to around 230% of the initial value 20 min after the injection of 10 mg kg(-1) cocaine. In a classical conditioning test, the dopamine signal in response to a cue increased to around 60 nM over 50 successive trials while the electrically evoked dopamine concentration decreased from about 90 to 50 nM in the maintenance phase. In contrast, the cue-evoked dopamine concentration progressively decreased and the electrically evoked dopamine was eliminated during the extinction phase. In the histological evaluation, there was little damage to brain tissue after five months chronic implantation of the stimulating electrode. SIGNIFICANCE We have developed an integrated wireless voltammetry system for measuring dopamine concentration and providing electrical stimulation. The developed wireless FSCV system is proven to be a useful experimental tool for the continuous monitoring of dopamine levels during animal learning behavior studies of freely moving rats.
Collapse
Affiliation(s)
- Yu-Ting Li
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan, Republic of China
| | | | | | | | | | | |
Collapse
|
6
|
Nakazato T. Dual modes of extracellular serotonin changes in the rat ventral striatum modulate adaptation to a social stress environment, studied with wireless voltammetry. Exp Brain Res 2012; 230:583-96. [DOI: 10.1007/s00221-012-3168-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2012] [Accepted: 06/25/2012] [Indexed: 02/03/2023]
|
7
|
Bazzu G, Puggioni GGM, Dedola S, Calia G, Rocchitta G, Migheli R, Desole MS, Lowry JP, O'Neill RD, Serra PA. Real-time monitoring of brain tissue oxygen using a miniaturized biotelemetric device implanted in freely moving rats. Anal Chem 2010; 81:2235-41. [PMID: 19222224 DOI: 10.1021/ac802390f] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
A miniaturized biotelemetric device for the amperometric detection of brain tissue oxygen is presented. The new system, derived from a previous design, has been coupled with a carbon microsensor for the real-time detection of dissolved O(2) in the striatum of freely moving rats. The implantable device consists of a single-supply sensor driver, a current-to-voltage converter, a microcontroller, and a miniaturized data transmitter. The oxygen current is converted to a digital value by means of an analog-to-digital converter integrated in a peripheral interface controller (PIC). The digital data is sent to a personal computer using a six-byte packet protocol by means of a miniaturized 434 MHz amplitude modulation (AM) transmitter. The receiver unit is connected to a personal computer (PC) via a universal serial bus. Custom developed software allows the PC to store and plot received data. The electronics were calibrated and tested in vitro under different experimental conditions and exhibited high stability, low power consumption, and good linear response in the nanoampere current range. The in vivo results confirmed previously published observations on oxygen dynamics in the striatum of freely moving rats. The system serves as a rapid and reliable model for studying the effects of different drugs on brain oxygen and brain blood flow and it is suited to work with direct-reduction sensors or O(2)-consuming biosensors.
Collapse
Affiliation(s)
- Gianfranco Bazzu
- Department of Neuroscience, Medical School, University of Sassari, Viale S. Pietro 43/b, 07100 Sassari, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Bledsoe JM, Kimble CJ, Covey DP, Blaha CD, Agnesi F, Mohseni P, Whitlock S, Johnson DM, Horne A, Bennet KE, Lee KH, Garris PA. Development of the Wireless Instantaneous Neurotransmitter Concentration System for intraoperative neurochemical monitoring using fast-scan cyclic voltammetry. J Neurosurg 2009; 111:712-23. [PMID: 19425890 PMCID: PMC2808191 DOI: 10.3171/2009.3.jns081348] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Emerging evidence supports the hypothesis that modulation of specific central neuronal systems contributes to the clinical efficacy of deep brain stimulation (DBS) and motor cortex stimulation (MCS). Real-time monitoring of the neurochemical output of targeted regions may therefore advance functional neurosurgery by, among other goals, providing a strategy for investigation of mechanisms, identification of new candidate neurotransmitters, and chemically guided placement of the stimulating electrode. The authors report the development of a device called the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for intraoperative neurochemical monitoring during functional neurosurgery. This device supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially and chemically resolved neurotransmitter measurements in the brain. METHODS The FSCV study consisted of a triangle wave scanned between -0.4 and 1 V at a rate of 300 V/second and applied at 10 Hz. All voltages were compared with an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single carbon fiber (r = 2.5 mum) into a glass capillary and pulling the capillary to a microscopic tip by using a pipette puller. The exposed carbon fiber (that is, the sensing region) extended beyond the glass insulation by approximately 100 microm. The neurotransmitter dopamine was selected as the analyte for most trials. Proof-of-principle tests included in vitro flow injection and noise analysis, and in vivo measurements in urethane-anesthetized rats by monitoring dopamine release in the striatum following high-frequency electrical stimulation of the medial forebrain bundle. Direct comparisons were made to a conventional hardwired system. RESULTS The WINCS, designed in compliance with FDA-recognized consensus standards for medical electrical device safety, consisted of 4 modules: 1) front-end analog circuit for FSCV (that is, current-to-voltage transducer); 2) Bluetooth transceiver; 3) microprocessor; and 4) direct-current battery. A Windows-XP laptop computer running custom software and equipped with a Universal Serial Bus-connected Bluetooth transceiver served as the base station. Computer software directed wireless data acquisition at 100 kilosamples/second and remote control of FSCV operation and adjustable waveform parameters. The WINCS provided reliable, high-fidelity measurements of dopamine and other neurochemicals such as serotonin, norepinephrine, and ascorbic acid by using FSCV at CFM and by flow injection analysis. In rats, the WINCS detected subsecond striatal dopamine release at the implanted sensor during high-frequency stimulation of ascending dopaminergic fibers. Overall, in vitro and in vivo testing demonstrated comparable signals to a conventional hardwired electrochemical system for FSCV. Importantly, the WINCS reduced susceptibility to electromagnetic noise typically found in an operating room setting. CONCLUSIONS Taken together, these results demonstrate that the WINCS is well suited for intraoperative neurochemical monitoring. It is anticipated that neurotransmitter measurements at an implanted chemical sensor will prove useful for advancing functional neurosurgery.
Collapse
Affiliation(s)
| | | | - Daniel P. Covey
- Department of Biological Sciences, Illinois State University, Normal, Illinois
| | | | - Filippo Agnesi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota
| | - Pedram Mohseni
- Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, Ohio
| | | | | | - April Horne
- Division of Engineering, Mayo Clinic, Rochester, Minnesota
| | | | - Kendall H. Lee
- Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota
| | - Paul A. Garris
- Department of Biological Sciences, Illinois State University, Normal, Illinois
| |
Collapse
|
9
|
Development of a Parallel-Computing Embedded Telemetry System for Voltammetric Microsensor and Biosensor Applications. SENSORS FOR ENVIRONMENT, HEALTH AND SECURITY 2009. [DOI: 10.1007/978-1-4020-9009-7_14] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
10
|
Abstract
Cells interact with each other by releasing signalling molecules, which can activate or inactivate target cells. In order to understand how coordination results from this communication, accurate measurements of these signalling molecules are prerequisite. Several different techniques exist to monitor and quantify these compounds, including enzymatic and histochemical assays, electrophysiological and optical recordings. However, there has been little use of electrochemical recordings in gastroenterological research, although these are very fast and sensitive. Electrochemical techniques rely on the simple fact that electroactive molecules can be oxidized at a given potential. The currents, elicited by the oxidation, are directly proportional to the concentration of the compound. In the current issue of Neurogastroenterology and Motility, electrochemical detection was successfully applied to measure nitric oxide (NO) from intestinal preparations. Although there are some important specificity, timing and spatial aspects to consider, this direct NO-probing technique is definitely a great asset to the field of gastrointestinal research and advances our understanding of NO signalling in the intestinal wall.
Collapse
Affiliation(s)
- P Vanden Berghe
- Center for Gastroenterological Research, KULeuven, Leuven, Belgium.
| |
Collapse
|
11
|
Nematollahi D, Shayani-jam H. Kinetic Study of Electrochemically Induced Michael Reactions of o-Quinones with Meldrum’s Acid Derivatives. Synthesis of Highly Oxygenated Catechols. J Org Chem 2008; 73:3428-34. [DOI: 10.1021/jo800115n] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- D. Nematollahi
- Faculty of Chemistry, University of Bu-Ali-Sina, Hamadan, 65174, Iran
| | - H. Shayani-jam
- Faculty of Chemistry, University of Bu-Ali-Sina, Hamadan, 65174, Iran
| |
Collapse
|
12
|
|
13
|
|
14
|
Kagohashi M, Nakazato T, Yoshimi K, Moizumi S, Hattori N, Kitazawa S. Wireless voltammetry recording in unanesthetised behaving rats. Neurosci Res 2007; 60:120-7. [PMID: 17983679 DOI: 10.1016/j.neures.2007.09.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2007] [Revised: 09/21/2007] [Accepted: 09/25/2007] [Indexed: 11/20/2022]
Abstract
In vivo voltammetry is a valuable technique for rapid measurement of dopamine in the brain of freely behaving rats. Using a conventional voltammetry system, however, behavioural freedom is restricted by cables connecting the head assembly to the measurement system. To overcome these difficulties, we developed a wireless voltammetry system utilizing radio waves. This system consisted of a potentiostat and transmitter system that was mounted on the back of the rat, and a receiver and analysis system. A single-step pulse (100-250 mV) was applied at 4 Hz after an activation pulse to a carbon fibre recording electrode (diameter: 7 microm). Measurement of dopamine (detection limit: 2.7 x 10(-7)M) was demonstrated in vitro. In vivo experiment was performed at least 1 week after the recording electrode was implanted in the rat striatum. Administration of 2-phenylethylamine to rats increased dopamine signal current, which was consistent with the result in the microdialysis measurement. During a resident-intruder test, dopamine signal current in a resident rat increased upon introduction of an intruder rat. These results show that the present wireless system is useful for a long-term measurement of dopamine in behaving rats.
Collapse
Affiliation(s)
- Maki Kagohashi
- Department of Physiology, Juntendo University School of Medicine, Hongo 2-1-1, Tokyo 113-0033, Japan
| | | | | | | | | | | |
Collapse
|
15
|
Takács B, Csoknya M, Gábriel R, Nagy G. Correlative morphometric and electrochemical measurements of serotonin content in earthworm muscles. ACTA ACUST UNITED AC 2007; 70:713-20. [PMID: 17509692 DOI: 10.1016/j.jbbm.2007.02.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2006] [Revised: 02/12/2007] [Accepted: 02/22/2007] [Indexed: 10/23/2022]
Abstract
Distribution of serotonin (5-HT) content of nervous fibers in both the somatic and the visceral muscle of Eisenia fetida have been investigated using immunocytochemical staining and voltammetric measurements. The somatic muscles in the body wall are richer innervated with serotoninergic fibers than the visceral ones in the pharynx and gizzard. The relative density of immunopositive fibers in the circular muscle layer of the body wall was found to be 2.73% while in the prostomium it was 1.02%. In the case of the muscle in pharynx 1.12% and in gizzard 1.28% density values were found. Differential Pulse Voltammetric (DPV) measurements with carbon fiber electrodes in the above mentioned muscle layers gave 272.5 nA, 135.0 nA, 122.5 nA, 137.5 nA peak heights, respectively. In the statistical analysis T-test was used at a confidence level of 95% (p<0.05). DPV current peak (i(p)) values reflect clearly the 5-HT concentration differences. Significant correlation was found between the innervation density and the i(p) values recorded in different areas. The i(p) values recorded at different times in different locations are determined by instantaneous serotonin concentration of the living tissue. As far as we know this is the first report using in vivo voltammetry investigating serotonin content in earthworm, E. fetida.
Collapse
Affiliation(s)
- Boglárka Takács
- Department of General and Physical Chemistry, University of Pécs, H-7624, Pécs, Hungary.
| | | | | | | |
Collapse
|