1
|
Alqarni Z, Rezgui Y, Petri I, Ghoroghi A. Viral infection transmission and indoor air quality: A systematic review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 923:171308. [PMID: 38432379 DOI: 10.1016/j.scitotenv.2024.171308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 02/03/2024] [Accepted: 02/25/2024] [Indexed: 03/05/2024]
Abstract
Respiratory disease transmission in indoor environments presents persistent challenges for health authorities, as exemplified by the recent COVID-19 pandemic. This underscores the urgent necessity to investigate the dynamics of viral infection transmission within indoor environments. This systematic review delves into the methodologies of respiratory infection transmission in indoor settings and explores how the quality of indoor air (IAQ) can be controlled to alleviate this risk while considering the imperative of sustainability. Among the 2722 articles reviewed, 178 were retained based on their focus on respiratory viral infection transmission and IAQ. Fifty eight articles delved into SARS-CoV-2 transmission, 21 papers evaluated IAQ in contexts of other pandemics, 53 papers assessed IAQ during the SARS-CoV-2 pandemic, and 46 papers examined control strategies to mitigate infectious transmission. Furthermore, of the 46 papers investigating control strategies, only nine considered energy consumption. These findings highlight clear gaps in current research, such as analyzing indoor air and surface samples for specific indoor environments, oversight of indoor and outdoor parameters (e.g., temperature, relative humidity (RH), and building orientation), neglect of occupancy schedules, and the absence of considerations for energy consumption while enhancing IAQ. This study distinctly identifies the indoor environmental conditions conducive to the thriving of each respiratory virus, offering IAQ trade-offs to mitigate the risk of dominant viruses at any given time. This study argues that future research should involve digital twins in conjunction with machine learning (ML) techniques. This approach aims to enhance IAQ by analyzing the transmission patterns of various respiratory viruses while considering energy consumption.
Collapse
Affiliation(s)
- Zahi Alqarni
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK; School of Computer Science, King Khalid University, Abha 62529, Saudi Arabia.
| | - Yacine Rezgui
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| | - Ioan Petri
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| | - Ali Ghoroghi
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| |
Collapse
|
2
|
Zhang Y, Hui FKP, Duffield C, Saeed AM. A review of facilities management interventions to mitigate respiratory infections in existing buildings. BUILDING AND ENVIRONMENT 2022; 221:109347. [PMID: 35782231 PMCID: PMC9238148 DOI: 10.1016/j.buildenv.2022.109347] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 05/01/2022] [Accepted: 06/23/2022] [Indexed: 06/15/2023]
Abstract
The Covid-19 pandemic reveals that the hazard of the respiratory virus was a secondary consideration in the design, development, construction, and management of public and commercial buildings. Retrofitting such buildings poses a significant challenge for building owners and facilities managers. This article reviews current research and practices in building operations interventions for indoor respiratory infection control from the perspective of facilities managers to assess the effectiveness of available solutions. This review systematically selects and synthesises eighty-six articles identified through the PRISMA process plus supplementary articles identified as part of the review process, that deal with facilities' operations and maintenance (O&M) interventions. The paper reviewed the context, interventions, mechanisms, and outcomes discussed in these articles, concluding that interventions for respiratory virus transmission in existing buildings fall into three categories under the Facilities Management (FM) discipline: Hard services (HVAC and drainage system controls) to prevent aerosol transmissions, Soft Services (cleaning and disinfection) to prevent fomite transmissions, and space management (space planning and occupancy controls) to eliminate droplet transmissions. Additionally, the research emphasised the need for FM intervention studies that examine occupant behaviours with integrated intervention results and guide FM intervention decision-making. This review expands the knowledge of FM for infection control and highlights future research opportunities.
Collapse
Affiliation(s)
- Yan Zhang
- Department of Infrastructure Engineering, University of Melbourne, Level 6, Building 290, 700 Swanston Street, Carlton, Victoria, Australia
| | - Felix Kin Peng Hui
- Department of Infrastructure Engineering, University of Melbourne, Australia
| | - Colin Duffield
- Department of Infrastructure Engineering, University of Melbourne, Australia
| | - Ali Mohammed Saeed
- Department of Jobs, Regions and Precincts, Level 13, 1 Spring Street, Melbourne, Victoria, Australia
| |
Collapse
|
3
|
Airborne infection risk assessment of COVID-19 in an inpatient department through on-site occupant behavior surveys. JOURNAL OF BUILDING ENGINEERING 2022; 51:104255. [PMCID: PMC8864063 DOI: 10.1016/j.jobe.2022.104255] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 02/06/2022] [Accepted: 02/17/2022] [Indexed: 05/26/2023]
Abstract
Airborne transmission is a possible infection route of the coronavirus disease 2019 (COVID-19). This investigation focuses on the airborne infection risk of COVID-19 in a nursing unit in an inpatient building in Shenzhen, China. On-site measurements and questionnaire surveys were conducted to obtain the air change rates and occupant trajectories, respectively. The aerosol transport and dose–response models were applied to evaluate the infection risk. The average outdoor air change rate measured in the wards was 1.1 h−1, which is below the minimum limit of 2.0 h−1 required by ASHRAE 170–2021. Considering the surveyed occupant behavior during one week, the patients and their attendants spent an average of 19.4 h/d and 15.1 h/d, respectively, in the wards, whereas the nurses primarily worked in the nurse station (3.0 h/d) and wards (2.4 h/d). The doctors primarily worked in their offices (2.6 h/d) and wards (1.1 h/d). Assuming one undetected COVID-19 infector emitting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the nursing unit, we calculated the accumulated viral dose and infection probabilities of the occupants. After one week, the cumulative infection risks of the patients and attendants were almost equal (0.002), and were higher than those of the nurses (0.0013) and doctors (0.0004). Proper protection measures, such as reducing the number of attendants, increasing the air change rate, and wearing masks, were found to reduce the infection risk. It should be noted that the reported results are based on several assumptions, such as the speculated virological properties of SARS-CoV-2 and the particular trajectories of occupants. Moreover, only second generations of transmission were taken into consideration, whereas in reality, the week-long exposure may cause third generation of transmission or worse.
Collapse
|
4
|
Xu Q, Goh HC, Mousavi E, Nabizadeh Rafsanjani H, Varghese Z, Pandit Y, Ghahramani A. Towards Personalization of Indoor Air Quality: Review of Sensing Requirements and Field Deployments. SENSORS (BASEL, SWITZERLAND) 2022; 22:3444. [PMID: 35591133 PMCID: PMC9104953 DOI: 10.3390/s22093444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 04/20/2022] [Accepted: 04/26/2022] [Indexed: 06/15/2023]
Abstract
As humans spend more time indoors, ensuring acceptable indoor air quality (IAQ) through ubiquitous sensing systems has become a necessity. Although extensive studies have been conducted on the IAQ sensing systems, a holistic review of the performance and deployment of Ubiquitous IAQ Sensing (UIAQS) systems with associated requirements in IAQ sensing standards is still lacking. In this study, we first reviewed IAQ pollutants and other IAQ-related factors and the associated requirements in the prominent IAQ sensing standards. We found that while non-pollutant factors are influential on occupants' perception of IAQ and their satisfaction, they do not have evaluation metrics in the IAQ standards. Then, we systematically reviewed field studies on UIAQS technologies in the literature. Specific classes of information were recorded and analyzed further. We found that the majority of the UIAQS systems did not meet the requirements of the prominent IAQ sensing standards and identified four primary research gaps. We concluded that a new holistic and personalized approach that incorporates UIAQS measurements and subjective feedback is needed. This study provides valuable insights for researchers and policymakers to better improve UIAQS technologies by developing personalized IAQ sensors and sensing standards.
Collapse
Affiliation(s)
- Qian Xu
- Department of the Built Environment, College of Design and Engineering, National University of Singapore, Singapore 119077, Singapore; (Q.X.); (H.C.G.)
| | - Hui Ci Goh
- Department of the Built Environment, College of Design and Engineering, National University of Singapore, Singapore 119077, Singapore; (Q.X.); (H.C.G.)
| | - Ehsan Mousavi
- Department of Construction Science and Management, Clemson University, Clemson, SC 29634, USA;
| | | | - Zubin Varghese
- Trane Technologies PLC Engineering & Technology Centre, Bangalore 560029, India; (Z.V.); (Y.P.)
| | - Yogesh Pandit
- Trane Technologies PLC Engineering & Technology Centre, Bangalore 560029, India; (Z.V.); (Y.P.)
| | - Ali Ghahramani
- Department of the Built Environment, College of Design and Engineering, National University of Singapore, Singapore 119077, Singapore; (Q.X.); (H.C.G.)
| |
Collapse
|
5
|
Mousavi ES, Mohammadi Nafchi A, DesJardins JD, LeMatty AS, Falconer RJ, Ashley ND, Roth BS, Moschella P. Design and in-vitro testing of a portable patient isolation chamber for bedside aerosol containment and filtration. BUILDING AND ENVIRONMENT 2022; 207:108467. [PMID: 34720358 PMCID: PMC8542519 DOI: 10.1016/j.buildenv.2021.108467] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 10/19/2021] [Accepted: 10/20/2021] [Indexed: 06/13/2023]
Abstract
The emergence of the SARS-CoV-2 pandemic has imposed a multitude of complications on healthcare facilities. Healthcare professionals had to develop creative solutions to deal with resource shortages and isolation spaces when caring for COVID positive patients. Among many other solutions, facilities have utilized engineering strategies to mitigate the spread of viral contamination within the hospital environment. One of the standard solutions has been the use of whole room negative pressurization (WRNP) to turn a general patient room into an infection isolation space. However, this has not always been easy due to many limitations, such as direct access to the outdoors and the availability of WRNP units. In operating rooms where a patient is likely to go through aerosol-generating procedures, other solutions must be considered because most operating rooms use positive pressure ventilation to maintain sterility. The research team has designed, built, and tested a Covering for Operations during Viral Emergency Response (COVER), a low-cost, portable isolation chamber that fits over a patient's torso on a hospital bed to contain and remove the pathogenic agents at the source (i.e., patient's mouth and nose). This study tests the performance of the COVER system under various design and performance scenarios using particle tracing techniques and compares its efficiency with WRNP units. The results show that COVER can dramatically reduce the concentration of particles within the room, while WRNP is only effective in preventing the room-induced particles from migrating to adjacent spaces.
Collapse
Affiliation(s)
- Ehsan S Mousavi
- Neiri Family Department of Construction Science and Management, Clemson University, Clemson, SC, 29634, USA
| | - Ali Mohammadi Nafchi
- Neiri Family Department of Construction Science and Management, Clemson University, Clemson, SC, 29634, USA
| | - John D DesJardins
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Amanda S LeMatty
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Robert J Falconer
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Noah D Ashley
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - Benjamin S Roth
- Prisma Health Upstate, University of South Carolina School of Medicine of Greenville, Greenville, SC, 29611, USA
| | - Phillip Moschella
- Prisma Health Upstate, University of South Carolina School of Medicine of Greenville, Greenville, SC, 29611, USA
| |
Collapse
|