1
|
Aharonov A, Sofer S, Bruck H, Sarig U, Sharabi M. Unveiling the mechanical role of radial fibers in meniscal tissue: Toward structural biomimetics. Acta Biomater 2024:S1742-7061(24)00468-9. [PMID: 39181178 DOI: 10.1016/j.actbio.2024.08.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 08/01/2024] [Accepted: 08/16/2024] [Indexed: 08/27/2024]
Abstract
The meniscus tissue is crucial for knee joint biomechanics and is frequently susceptible to injuries resulting in early-onset osteoarthritis. Consequently, the need for meniscal substitutes spurs ongoing development. The meniscus is a composite tissue reinforced with circumferential and radial collagenous fibers; the mechanical role of the latter has yet to be fully unveiled. Here, we investigated the role of radial fibers using a synergistic methodology combining meniscal tissue structure imaging, a computational knee joint model, and the fabrication of simple biomimetic composite laminates. These laminates mimic the basic structural units of the meniscus, utilizing longitudinal and transverse fibers equivalent to the circumferential and radial fibers in meniscal tissue. In the computational model, the absence of radial fibers resulted in stress concentration within the meniscus matrix and up to 800 % greater area at the same stress level. Furthermore, the contact pressure on the tibial cartilage increased drastically, affecting up to 322 % larger areas. Conversely, in models with radial fibers, we observed up to 25 % lower peak contact pressures and width changes of less than 0.1 %. Correspondingly, biomimetic composite laminates containing transverse fibers exhibited minor transverse deformations and smaller Poisson's ratios. They demonstrated structural shielding ability, maintaining their mechanical performance with the reduced amount of fibers in the loading direction, similar to the ability of the torn meniscus to carry and transfer loads to some extent. These results indicate that radial fibers are essential to distribute contact pressure and tensile stresses and prevent excessive deformations, suggesting the importance of incorporating them in novel designs of meniscal substitutes. STATEMENT OF SIGNIFICANCE: The organization of the collagen fibers in the meniscus tissue is crucial to its biomechanical function. Radially oriented fibers are an important structural element of the meniscus and greatly affect its mechanical behavior. However, despite their importance to the meniscus mechanical function, radially oriented fibers receive minor attention in meniscal substitute designs. Here, we used a synergistic methodology that combines imaging of the meniscal tissue structure, a structural computational model of the knee joint, and the fabrication of simplistic biomimetic composite laminates that mimic the basic structural units of the meniscus. Our findings highlight the importance of the radially oriented fibers, their mechanical role in the meniscus tissue, and their importance as a crucial element in engineering novel meniscal substitutes.
Collapse
Affiliation(s)
- Adi Aharonov
- Department of Mechanical Engineering and Mechatronics, Ariel University, Ariel 407000, Israel
| | - Shachar Sofer
- Dr. Miriam and Sheldon Adelson School of Medicine, Department of Morphological Sciences and Teratology, Ariel University, Ariel 407000, Israel
| | - Hod Bruck
- Dr. Miriam and Sheldon Adelson School of Medicine, Department of Morphological Sciences and Teratology, Ariel University, Ariel 407000, Israel
| | - Udi Sarig
- Dr. Miriam and Sheldon Adelson School of Medicine, Department of Morphological Sciences and Teratology, Ariel University, Ariel 407000, Israel; Department of Chemical Engineering, School of Engineering, Ariel University, Ariel 407000, Israel
| | - Mirit Sharabi
- Department of Mechanical Engineering and Mechatronics, Ariel University, Ariel 407000, Israel.
| |
Collapse
|
2
|
Hashimoto S, Ohsawa T, Omae H, Oshima A, Takase R, Chikuda H. Extracorporeal shockwave therapy for degenerative meniscal tears results in a decreased T2 relaxation time and pain relief: An exploratory randomized clinical trial. Knee Surg Sports Traumatol Arthrosc 2024. [PMID: 39101450 DOI: 10.1002/ksa.12384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 07/03/2024] [Accepted: 07/08/2024] [Indexed: 08/06/2024]
Abstract
PURPOSE The optimal management of degenerative meniscal tears remains controversial. Extracorporeal shockwave therapy (ESWT) has been shown to promote tissue repair in both preclinical and clinical studies; however, its effect on degenerative meniscal tears remains unknown. This study aimed to examine whether ESWT improves meniscal degeneration. METHODS This randomized trial was conducted between 2020 and 2022 and involved patients with degenerative medial meniscal tears. Patients were allocated to receive either focused ESWT (0.25 mJ/mm2, 2000 impulses, 3 sessions with a 1-week interval) or sham treatment. Patients were evaluated using magnetic resonance imaging (MRI) before treatment and at 12 months after treatment. The primary endpoint was improvement in meniscal degeneration, as assessed by the change in T2 relaxation time from baseline on MRI T2 mapping. Knee pain and clinical outcomes were also examined at the same time. RESULTS Of 29 randomized patients, 27 patients (mean age 63.9 ± 8.7 years; females 37%; ESWT group 14 patients; control group 13 patients) were included in the final analysis. At 12 months postintervention, patients in the ESWT group showed a greater decrease in the T2 relaxation time (ESWT group -2.9 ± 1.7 ms vs. control group 1.0 ± 1.9 ms; p < 0.001) and had less knee pain (p = 0.04). The clinical outcomes at 12 months post-treatment were not statistically significant. No adverse events were reported. CONCLUSION ESWT decreased the T2 relaxation time in the meniscus at 12 months post-treatment. ESWT also provided pain relief, but no differences were observed in clinical outcomes. LEVEL OF EVIDENCE Level II.
Collapse
Affiliation(s)
- Shogo Hashimoto
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan
| | - Takashi Ohsawa
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan
| | - Hiroaki Omae
- Department of Orthopaedic Surgery, Zenshukai Hospital, Maebashi, Gunma, Japan
| | - Atsufumi Oshima
- Department of Orthopaedic Surgery, Takasaki Genaral Medical Center, Takasaki, Gunma, Japan
| | - Ryota Takase
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan
| | - Hirotaka Chikuda
- Department of Orthopaedic Surgery, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan
| |
Collapse
|
3
|
Seitz AM, Niehoff A. [Tissue biomechanics: connective tissue characterization : Cluster tissue biomechanics]. ORTHOPADIE (HEIDELBERG, GERMANY) 2024; 53:503-510. [PMID: 38829400 DOI: 10.1007/s00132-024-04517-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/02/2024] [Indexed: 06/05/2024]
Abstract
The various connective tissues of the body have different functions, which result from their specific structure and composition. The identification of this structure-function relationship is of great importance for various disciplines such as medicine, biology or tissue engineering. Connective tissue consists mainly of an extracellular matrix (ECM) and a limited number of cells. It is extremely adaptable because the activity of the cells remodels the composition and structure of the ECM in order to adapt the mechanical properties (functions) to the new demands (e.g. an increased mechanical stimulus).
Collapse
Affiliation(s)
- Andreas Martin Seitz
- Institut für Unfallchirurgische Forschung und Biomechanik, Zentrum für Traumaforschung Ulm, Universitätsklinikum Ulm, Helmholtzstraße 14, 89081, Ulm, Deutschland.
| | - Anja Niehoff
- Institut für Biomechanik und Orthopädie, Deutsche Sporthochschule Köln, Am Sportpark Müngersdorf 6, 50933, Köln, Deutschland.
- Cologne Center for Musculoskeletal Biomechanics, Medizinische Fakultät, Universität zu Köln, Joseph-Stelzmann-Str. 9, 50931, Köln, Deutschland.
| |
Collapse
|
4
|
de Roy L, Schlickenrieder K, Rüger M, Faschingbauer M, Ignatius A, Seitz AM. Impact of degeneration and material pairings on cartilage friction: Cartilage versus glass. J Orthop Res 2024; 42:745-752. [PMID: 37975270 DOI: 10.1002/jor.25738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 10/17/2023] [Accepted: 11/14/2023] [Indexed: 11/19/2023]
Abstract
The association of knee joint osteoarthritis and altered frictional properties of the degenerated cartilage remains ambiguous, because previous in vitro studies did not consider the characteristic loads and velocities during gait. Therefore, the aim of this study was to quantify the friction behavior of degenerated human cartilage under characteristic stance and swing phase conditions. A dynamic pin-on-plate tribometer was used to test the tribological systems of cartilage against cartilage and cartilage against glass, both with synthetic synovial fluid as lubricant. Using the International Cartilage Repair Society classification, the cartilage samples were assigned to a mildly or a severely degenerated group before testing. Friction coefficients were calculated under stance and swing phase conditions at the beginning of the test and after 600 s of testing. The most important finding of this study is that cartilage against glass couplings displayed significantly higher friction for the severely degenerated samples compared to the mildly degenerated ones, whereas cartilage against cartilage couplings only indicated slight tendencies under the observed test conditions. Consequently, care should be taken when transferring in vitro findings from cartilage against cartilage couplings to predict the friction behavior in vivo. Therefore, we recommend in vitro tribological testing methods which account for gait-like loading conditions and to replicate physiological material pairings, particularly in preclinical medical device validation studies.
Collapse
Affiliation(s)
- Luisa de Roy
- Institute of Orthopedic Research and Biomechanics, Ulm University Medical Center, Ulm, Germany
| | - Klaus Schlickenrieder
- Faculty of Production Engineering and Management, Ulm University of Applied Sciences, Ulm, Germany
| | - Matthias Rüger
- Department of Pediatric Orthopedics and Traumatology, University Children's Hospital, University of Zurich, Zurich, Switzerland
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Martin Faschingbauer
- Department of Orthopedic Surgery, RKU, Ulm University Medical Center, Ulm, Germany
| | - Anita Ignatius
- Institute of Orthopedic Research and Biomechanics, Ulm University Medical Center, Ulm, Germany
| | - Andreas M Seitz
- Institute of Orthopedic Research and Biomechanics, Ulm University Medical Center, Ulm, Germany
| |
Collapse
|
5
|
Yan M, Liang T, Zhao H, Bi Y, Wang T, Yu T, Zhang Y. Model Properties and Clinical Application in the Finite Element Analysis of Knee Joint: A Review. Orthop Surg 2024; 16:289-302. [PMID: 38174410 PMCID: PMC10834231 DOI: 10.1111/os.13980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/21/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024] Open
Abstract
The knee is the most complex joint in the human body, including bony structures like the femur, tibia, fibula, and patella, and soft tissues like menisci, ligaments, muscles, and tendons. Complex anatomical structures of the knee joint make it difficult to conduct precise biomechanical research and explore the mechanism of movement and injury. The finite element model (FEM), as an important engineering analysis technique, has been widely used in many fields of bioengineering research. The FEM has advantages in the biomechanical analysis of objects with complex structures. Researchers can use this technology to construct a human knee joint model and perform biomechanical analysis on it. At the same time, finite element analysis can effectively evaluate variables such as stress, strain, displacement, and rotation, helping to predict injury mechanisms and optimize surgical techniques, which make up for the shortcomings of traditional biomechanics experimental research. However, few papers introduce what material properties should be selected for each anatomic structure of knee FEM to meet different research purposes. Based on previous finite element studies of the knee joint, this paper summarizes various modeling strategies and applications, serving as a reference for constructing knee joint models and research design.
Collapse
Affiliation(s)
- Mingyue Yan
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Ting Liang
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Haibo Zhao
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Yanchi Bi
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
| | - Tianrui Wang
- Department of Orthopedics, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Tengbo Yu
- Institute of Sports Medicine and Health, Qingdao University, Qingdao, China
- Department of Orthopedic Surgery, Qingdao Hospital, University of Health and Rehabilitation Sciences (Qingdao Municipal Hospital), Qingdao, China
| | - Yingze Zhang
- Department of Orthopedics, The Third Hospital of Hebei Medical University, Shijiazhuang, China
| |
Collapse
|
6
|
Schwer J, Ignatius A, Seitz AM. The biomechanical properties of human menisci: A systematic review. Acta Biomater 2024; 175:1-26. [PMID: 38092252 DOI: 10.1016/j.actbio.2023.12.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Revised: 11/09/2023] [Accepted: 12/06/2023] [Indexed: 01/08/2024]
Abstract
Biomechanical characterization of meniscal tissue ex vivo remains a critical need, particularly for the development of suitable meniscus replacements or therapeutic strategies that target the native mechanical properties of the meniscus. To date, a huge variety of test configurations and protocols have been reported, making it extremely difficult to compare the respective outcome parameters, thereby leading to misinterpretation. Therefore, the purpose of this systematic review was to identify test-specific parameters that contribute to uncertainties in the determination of mechanical properties of the human meniscus and its attachments, which derived from common quasi-static and dynamic tests in tension, compression, and shear. Strong evidence was found that the determined biomechanical properties vary significantly depending on the specific test parameters, as indicated by up to tenfold differences in both tensile and compressive properties. Test mode (stress relaxation, creep, cyclic) and configuration (unconfined, confined, in-situ), specimen shape and dimensions, preconditioning regimes, loading rates, post-processing of experimental data, and specimen age and degeneration were identified as the most critical parameters influencing the outcome measures. In conclusion, this work highlights an unmet need for standardization and reporting guidelines to facilitate comparability and may prove beneficial for evaluating the mechanical properties of novel meniscus constructs. STATEMENT OF SIGNIFICANCE: The biomechanical properties of the human meniscus have been studied extensively over the past decades. However, it remains unclear to what extent both test protocol and specimen-related differences are responsible for the enormous variability in material properties. Therefore, this systematic review analyzes the biomechanical properties of the human meniscus in the context of the underlying testing protocol. The most sensitive parameters affecting the determination of mechanical properties were identified and critically discussed. Currently, it is of utmost importance for scientists evaluating potential meniscal scaffolds and biomaterials to have a control group rather than a direct comparison to the literature. Standardization of both test procedures and reporting requirements is needed to improve and accelerate the development of meniscal replacement constructs.
Collapse
Affiliation(s)
- Jonas Schwer
- Institute of Orthopedic Research and Biomechanics, Center for Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
| | - Anita Ignatius
- Institute of Orthopedic Research and Biomechanics, Center for Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
| | - Andreas Martin Seitz
- Institute of Orthopedic Research and Biomechanics, Center for Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany.
| |
Collapse
|
7
|
Mahmood F, Clarke J, Riches P. Is the mechanical function of meniscal tissue altered in osteoarthritic knees? Knee 2023; 44:194-200. [PMID: 37672911 DOI: 10.1016/j.knee.2023.08.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 07/27/2023] [Accepted: 08/11/2023] [Indexed: 09/08/2023]
Abstract
BACKGROUND Deteriorating meniscal function is thought to play a role in knee osteoarthritis. Meniscal proteoglycans maintain mechanical stiffness of the tissue through electrostatic effects. This study aimed to investigate whether the mechanical properties of macroscopically intact meniscus are preserved in osteoarthritis. METHODS Discs of lateral meniscal tissue two millimetres thick and of five millimetres diameter from osteoarthritic knees and from healthy donors were placed within a confined compression chamber, mounted in a materials testing machine and bathed in isotonic 0.14M PBS, hypotonic deionised water or hypertonic 3M PBS. Following equilibrium, a 10% ramp compressive strain was applied followed by a 7200 second hold. Resultant stress relaxation curves were fitted to a nonlinear poroviscoelastic model with strain dependent permeability using finite element modelling to determine mechanical parameters. All samples were assayed for proteoglycan content. Comparison of results was undertaken using multivariate ANOVA. RESULTS Thirty samples from osteoarthritic knees and 18 samples from healthy donors were tested. No significant differences in mechanical parameters or proteoglycan content was observed between groups. In both groups Young's modulus (E) was significantly greater, and zero-strain permeability significantly reduced, in samples tested in deionised water compared to samples tested in 0.14M or 3M PBS (all p < 0.05). CONCLUSION Mechanical parameters of intact lateral meniscus in osteoarthritic knees are similar to those found in healthy knees. Proteoglycan concentration and their electrostatic contribution to mechanical stiffness of the meniscus is maintained in menisci derived from osteoarthritic knees. Whilst macroscopic tears in the meniscal ultrastructure may contribute to osteoarthritis, intact meniscal tissue maintains its function.
Collapse
Affiliation(s)
- Fahd Mahmood
- Department of Orthopaedics, Golden Jubilee National Hospital, Agamemnon Street, Clydebank G81 4DY, United Kingdom.
| | - Jon Clarke
- Department of Orthopaedics, Golden Jubilee National Hospital, Agamemnon Street, Clydebank G81 4DY, United Kingdom
| | - Philip Riches
- Department of Biomedical Engineering, Wolfson Centre, University of Strathclyde, 16 Richmond Street, Glasgow G1 1XQ, United Kingdom
| |
Collapse
|
8
|
Morejon A, Schwartz G, Best TM, Travascio F, Jackson AR. Effect of molecular weight and tissue layer on solute partitioning in the knee meniscus. OSTEOARTHRITIS AND CARTILAGE OPEN 2023; 5:100360. [PMID: 37122844 PMCID: PMC10133802 DOI: 10.1016/j.ocarto.2023.100360] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 04/04/2023] [Indexed: 05/02/2023] Open
Abstract
Objective Knee meniscus tissue is partly vascularized, meaning that nutrients must be transported through the extracellular matrix of the avascular portion to reach resident cells. Similarly, drugs used as therapeutic agents to treat meniscal pathologies rely on transport through the tissue. The driving force of diffusive transport is the gradient of concentration, which depends on molecular solubility. The meniscus is organized into a core region sandwiched between the tibial and femoral superficial layers. Structural differences exist across meniscal regions; therefore, regional differences in solubility are also hypothesized. Methods Samples from the core, tibial and femoral layers were obtained from 5 medial and 5 lateral porcine menisci. The partition coefficient (K) of fluorescein, 3 kDa and 40 kDa dextrans in the layers of the meniscus was measured using an equilibration experiment. The effect of meniscal compartment, layer, and solute molecular weight on K was analyzed using a three-way ANOVA. Results K ranged from a high of ∼2.9 in fluorescein to a low of ∼0.1 in 40 kDa dextran and was inversely related to the solute molecular weight across all tissue regions. Tissue layer only had a significant effect on partitioning of 40k Dex solute, which was lower in the tibial surface layer relative to the core (p = 0.032). Conclusion This study provides insight into depth-dependent partitioning in the meniscus, indicating the limiting effect of the meniscus superficial layer on solubility increases with solute molecular size. This illustrates how the surface layers could potentially reduce the effectiveness of drug delivery therapies incorporating large molecules (>40 kDa).
Collapse
Affiliation(s)
- Andy Morejon
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL, USA
| | - Gabi Schwartz
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA
| | - Thomas M. Best
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA
- Department of Orthopedic Surgery, University of Miami, Coral Gables, FL, USA
- UHealth Sports Medicine Institute, Coral Gables, FL, USA
| | - Francesco Travascio
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL, USA
- Department of Orthopedic Surgery, University of Miami, Coral Gables, FL, USA
- Max Biedermann Institute for Biomechanics at Mount Sinai Medical Center, Miami Beach, FL, USA
- Corresponding author. College of Engineering, University of Miami, 1251 Memorial Drive, MEB 276, Coral Gables, FL 33146, USA.
| | - Alicia R. Jackson
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA
- Corresponding author. College of Engineering, University of Miami, 1251 Memorial Drive, MEA 219, Coral Gables, FL 33146 USA.
| |
Collapse
|
9
|
Morejon A, Dalbo PL, Best TM, Jackson AR, Travascio F. Tensile energy dissipation and mechanical properties of the knee meniscus: relationship with fiber orientation, tissue layer, and water content. Front Bioeng Biotechnol 2023; 11:1205512. [PMID: 37324417 PMCID: PMC10264653 DOI: 10.3389/fbioe.2023.1205512] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 05/22/2023] [Indexed: 06/17/2023] Open
Abstract
Introduction: The knee meniscus distributes and dampens mechanical loads. It is composed of water (∼70%) and a porous fibrous matrix (∼30%) with a central core that is reinforced by circumferential collagen fibers enclosed by mesh-like superficial tibial and femoral layers. Daily loading activities produce mechanical tensile loads which are transferred through and dissipated by the meniscus. Therefore, the objective of this study was to measure how tensile mechanical properties and extent of energy dissipation vary by tension direction, meniscal layer, and water content. Methods: The central regions of porcine meniscal pairs (n = 8) were cut into tensile samples (4.7 mm length, 2.1 mm width, and 0.356 mm thickness) from core, femoral and tibial components. Core samples were prepared parallel (circumferential) and perpendicular (radial) to the fibers. Tensile testing consisted of frequency sweeps (0.01-1Hz) followed by quasi-static loading to failure. Dynamic testing yielded energy dissipation (ED), complex modulus (E*), and phase shift (δ) while quasi-static tests yielded Young's Modulus (E), ultimate tensile strength (UTS), and strain at UTS (εUTS). To investigate how ED is influenced by the specific mechanical parameters, linear regressions were performed. Correlations between sample water content (φw) and mechanical properties were investigated. A total of 64 samples were evaluated. Results: Dynamic tests showed that increasing loading frequency significantly reduced ED (p < 0.05). Circumferential samples had higher ED, E*, E, and UTS than radial ones (p < 0.001). Stiffness was highly correlated with ED (R2 > 0.75, p < 0.01). No differences were found between superficial and circumferential core layers. ED, E*, E, and UTS trended negatively with φw (p < 0.05). Discussion: Energy dissipation, stiffness, and strength are highly dependent on loading direction. A significant amount of energy dissipation may be associated with time-dependent reorganization of matrix fibers. This is the first study to analyze the tensile dynamic properties and energy dissipation of the meniscus surface layers. Results provide new insights on the mechanics and function of meniscal tissue.
Collapse
Affiliation(s)
- Andy Morejon
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL, United States
| | - Pedro L. Dalbo
- School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, United States
| | - Thomas M. Best
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States
- Department of Orthopedic Surgery, University of Miami, Coral Gables, FL, United States
- UHealth Sports Medicine Institute, Coral Gables, FL, United States
| | - Alicia R. Jackson
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States
| | - Francesco Travascio
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL, United States
- Department of Orthopedic Surgery, University of Miami, Coral Gables, FL, United States
- Max Biedermann Institute for Biomechanics at Mount Sinai Medical Center, Miami Beach, FL, United States
| |
Collapse
|
10
|
Gouldin AG, Patel NK, Golladay GJ, Puetzer JL. Advanced glycation end-product accumulation differs by location and sex in aged osteoarthritic human menisci. Osteoarthritis Cartilage 2023; 31:363-373. [PMID: 36494052 PMCID: PMC10088070 DOI: 10.1016/j.joca.2022.11.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 11/15/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVE There is a clear link between increasing age and meniscus degeneration, leading to increased injury, osteoarthritis (OA) progression, and often total knee replacement. Advanced glycation end-products (AGEs) are non-enzymatic crosslinks and adducts that accumulate in collagen with age, altering tissue mechanics and cell function, ultimately leading to increased injury and inflammation. AGEs, both fluorescent and non-fluorescent, play a central role in age-related degradation of tissues throughout the body; however, little is known about their role in meniscus degeneration. The objective of this study was to characterize changes in aged OA menisci, specifically evaluating zonal AGE accumulation, to gain a better understanding of changes that may lead to age-related meniscal degeneration. METHOD Deidentified human menisci (N = 48, 52-84 years old) were obtained from subjects undergoing total knee replacement. Changes in extracellular matrix (ECM) were assessed by gross morphology, confocal analysis, and biochemical assays. Deoxyribonucleic acid (DNA), glycosaminoglycan (GAG), collagen, and AGE accumulation were compared with patient age, zonal region, and patient sex. RESULTS There were minimal changes in DNA, GAG, and collagen concentration with age or zone. However, collagen fraying and AGEs increased with age, with more AGEs accumulating in the meniscal horns compared to the central body and in male menisci compared to females. CONCLUSIONS Overall, this work provides greater insights into regional changes that occur in human menisci with age and OA. These results suggest AGEs may play a role in the degeneration of the meniscus, with AGEs being a possible target to reduce age-related tears, degeneration, and OA progression.
Collapse
Affiliation(s)
- A G Gouldin
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA, United States.
| | - N K Patel
- Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA, United States.
| | - G J Golladay
- Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA, United States.
| | - J L Puetzer
- Department of Biomedical Engineering, Virginia Commonwealth University, Richmond, VA, United States; Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA, United States.
| |
Collapse
|
11
|
Bradley PX, Thomas KN, Kratzer AL, Robinson AC, Wittstein JR, DeFrate LE, McNulty AL. The Interplay of Biomechanical and Biological Changes Following Meniscus Injury. Curr Rheumatol Rep 2023; 25:35-46. [PMID: 36479669 PMCID: PMC10267895 DOI: 10.1007/s11926-022-01093-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/31/2022] [Indexed: 12/12/2022]
Abstract
PURPOSE OF REVIEW Meniscus injury often leads to joint degeneration and post-traumatic osteoarthritis (PTOA) development. Therefore, the purpose of this review is to outline the current understanding of biomechanical and biological repercussions following meniscus injury and how these changes impact meniscus repair and PTOA development. Moreover, we identify key gaps in knowledge that must be further investigated to improve meniscus healing and prevent PTOA. RECENT FINDINGS Following meniscus injury, both biomechanical and biological alterations frequently occur in multiple tissues in the joint. Biomechanically, meniscus tears compromise the ability of the meniscus to transfer load in the joint, making the cartilage more vulnerable to increased strain. Biologically, the post-injury environment is often characterized by an increase in pro-inflammatory cytokines, catabolic enzymes, and immune cells. These multi-faceted changes have a significant interplay and result in an environment that opposes tissue repair and contributes to PTOA development. Additionally, degenerative changes associated with OA may cause a feedback cycle, negatively impacting the healing capacity of the meniscus. Strides have been made towards understanding post-injury biological and biomechanical changes in the joint, their interplay, and how they affect healing and PTOA development. However, in order to improve clinical treatments to promote meniscus healing and prevent PTOA development, there is an urgent need to understand the physiologic changes in the joint following injury. In particular, work is needed on the in vivo characterization of the temporal biomechanical and biological changes that occur in patients following meniscus injury and how these changes contribute to PTOA development.
Collapse
Affiliation(s)
- Patrick X Bradley
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA
| | - Karl N Thomas
- Department of Orthopaedic Surgery, Duke University School of Medicine, DUMC Box 3093, Durham, NC, 27710, USA
| | - Avery L Kratzer
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Allison C Robinson
- Department of Orthopaedic Surgery, Duke University School of Medicine, DUMC Box 3093, Durham, NC, 27710, USA
| | - Jocelyn R Wittstein
- Department of Orthopaedic Surgery, Duke University School of Medicine, DUMC Box 3093, Durham, NC, 27710, USA
| | - Louis E DeFrate
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA
- Department of Orthopaedic Surgery, Duke University School of Medicine, DUMC Box 3093, Durham, NC, 27710, USA
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Amy L McNulty
- Department of Orthopaedic Surgery, Duke University School of Medicine, DUMC Box 3093, Durham, NC, 27710, USA.
- Department of Biomedical Engineering, Duke University, Durham, NC, USA.
- Department of Pathology, Duke University School of Medicine, Durham, NC, USA.
| |
Collapse
|
12
|
Li W, Li T, Xi X, Zhang R, Sun W, Zhang D, Gong W. Does higher knee hyperextension in patients with hemiplegia affect lateral and medial meniscus volume in the paretic leg? A cross-sectional study. BMC Sports Sci Med Rehabil 2023; 15:4. [PMID: 36600322 DOI: 10.1186/s13102-022-00611-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 12/19/2022] [Indexed: 01/06/2023]
Abstract
BACKGROUND After stroke, an abnormal gait pattern gradually leads to knee pain and joint lesions, resulting the gait instability. However, the correlation between the knee hyperextension and gait pattern, the meniscus volume, and the water content of meniscus in paretic and non-paretic legs has not been fully investigated. Moreover, most of physicians tend to ignore this knee hyperextension. This study attempted to emphasize the importance of knee hyperextension using gait analysis and Magnetic resonance imaging (Trial registration number ChiCTR2000039641, date of registration 04/11/2020). METHODS Eight patients with chronic hemiplegic (6 male, 2 female) volunteered to participate in this study. Participants was recruited if they had a hemiplegia following a stroke occurring more than 6 months, had an ability to walk 10 m without aids, had a Function Ambulation Category level at least 3 and above, and had a hemiplegic lower extremity identified as Brunnstrom state III or above identification. The spatial-temporal gait parameters and kinematic parameters in the paretic and the non-paretic legs and the percentage of free water content in deep and shallow layers. RESULTS Longer time since hemiplegia led to larger angles of knee hyperextension (R = 0.56, p = 0.016), larger angles of knee hyperextension led to more tears in meniscus (R = - 0.53, - 0,57 and - 0.70), and larger angles of knee hyperextension decreased water content of the lateral meniscus in the non-paretic leg (R = - 0.91) but increased water content of the medial meniscus (R = 0.53 and 0.63). CONCLUSIONS The knee hyperextension could not be ignored by physicians and needed to be diagnosed and treated as early as possible, the time since hemiplegia could be an indicator of sign of knee hyperextension.
Collapse
Affiliation(s)
- Wenshan Li
- Beijing Rehabilitation Medicine Academy, Capital Medical University, Beijing, 100144, China
| | - Tiancong Li
- Beijing Rehabilitation Medicine Academy, Capital Medical University, Beijing, 100144, China
| | - Xiaoshuang Xi
- Beijing Rehabilitation Medicine Academy, Capital Medical University, Beijing, 100144, China
| | - Rong Zhang
- Second Clinical Medical Academy, Yunnan University of Chinese Medicine, Kunming, Yunnan, 650500, China
| | - Weishuang Sun
- Rehabilitation Medicine Academy, Weifang Medical University, Weifang, Shandong, 261053, China
| | - Dan Zhang
- Rehabilitation Medicine Academy, Weifang Medical University, Weifang, Shandong, 261053, China
| | - Weijun Gong
- Department of Neurological Rehabilitation, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, 100144, China.
| |
Collapse
|
13
|
Bone Marrow-Derived Fibrin Clots Stimulate Healing of a Meniscal Defect in a Rabbit Model. Arthroscopy 2022:S0749-8063(22)00838-6. [PMID: 36574822 DOI: 10.1016/j.arthro.2022.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 11/25/2022] [Accepted: 12/01/2022] [Indexed: 12/26/2022]
Abstract
PURPOSE To determine the in vivo effectiveness of bone marrow aspirate-derived (BMA) fibrin clots for avascular meniscal defect healing in a rabbit model. METHODS In 42 Japanese white rabbits, a 2.0-mm cylindrical defect was introduced into the avascular zone of the anterior part of the medial meniscus in the bilateral knees. The rabbits were grouped according to implantation of a BMA fibrin clot (BMA group) or a peripheral blood (PB)-derived clot (PB group) into the defect and nonimplantation (control group). Macroscopic and histological assessments were performed using a scoring system at 4 and 12 weeks after surgery. At 12 weeks after surgery, compressive stress was analyzed biomechanically. RESULTS The meniscal score in the BMA group (12.1) was greater than that in the PB group (5.5; P = .031) and control group (4.4; P = .013) at 4 weeks. The meniscal score in the BMA group (13.1) was greater than that in the control group (6.4; BMA = 13.1; P = .0046) at 12 weeks. In the biomechanical analysis, the BMA group demonstrated significantly higher compressive strength than the PB group (6.6 MPa) (BMA = 15.4 MPa; P = .0201) and control group (3.6 MPa; BMA = 15.4 MPa; P = .007). CONCLUSIONS Implantation of BMA fibrin clots into the meniscal defect of the avascular zone in a rabbit model improved the meniscal score at 4 weeks and strengthened the reparative meniscal tissue at 12 weeks compared with the implantation of PB fibrin clots. CLINICAL RELEVANCE Healing in the avascular zone of the meniscus can be problematic. Approaches to improving this healing response have had variable results. This study provides additional information that may help improve the outcomes in patients with these injuries.
Collapse
|
14
|
Experiments and hyperelastic modeling of porcine meniscus show heterogeneity at high strains. Biomech Model Mechanobiol 2022; 21:1641-1658. [PMID: 35882676 DOI: 10.1007/s10237-022-01611-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 07/01/2022] [Indexed: 11/02/2022]
Abstract
Constitutive modeling of the meniscus is critical in areas like knee surgery and tissue engineering. At low strain rates, the meniscus can be described using a hyperelastic model. Calibration of hyperelastic material models of the meniscus is challenging on many fronts due to material variability and friction. In this study, we present a framework to determine the hyperelastic material parameters of porcine meniscus (and similar soft tissues) using no-slip uniaxial compression experiments. Because of the nonhomogeneous deformation in the specimens, a finite element solution is required at each step of the iterative calibration process. We employ a Bayesian calibration approach to account for the inherent material variability and a Bayesian optimization approach to minimize the resulting cost function in the material parameter space. Cylindrical specimens of porcine meniscus from the anterior, middle and posterior regions are tested up to 30% compressive strain and the Yeoh form of hyperelastic strain energy density function is used to describe the material response. The results show that the Yeoh form is able to accurately describe the compressive response of porcine meniscus and that the Bayesian calibration and optimization approaches are able to calibrate the model in a computationally efficient manner while taking into account the inherent material variability. The results also show that the shear modulus or the initial stiffness is roughly uniform across the different areas of the meniscus, but there is significant spatial heterogeneity in the response at high strains. In particular, the middle region is considerably stiffer at high strains. This heterogeneity is important to consider in modeling the response of the meniscus for clinical applications.
Collapse
|
15
|
Meniscus surface texture is associated with degenerative changes in biological and biomechanical properties. Sci Rep 2022; 12:11977. [PMID: 35831482 PMCID: PMC9279509 DOI: 10.1038/s41598-022-16206-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 07/06/2022] [Indexed: 11/08/2022] Open
Abstract
Meniscal degeneration is defined by semi-quantitative assessment of multiple histological findings and has been implicated in biomechanical dysfunction, yet little is known about its relationship with biological properties. This paper aimed to quantitatively evaluate degenerative findings in human meniscus to examine their relationship with gene expression and biomechanical properties, and to extract histological findings that reflect biological properties like gene expression and cytokine secretion. This study included lateral menisci of 29 patients who underwent total knee arthroplasty. The menisci were divided into six samples. For each sample, Pauli's histological evaluation and corresponding quantitative assessment (surface roughness, DNA content, collagen orientation, and GAG content) were performed, with surface roughness showing the highest correlation with the histological evaluation in a single correlation analysis (r = 0.66, p < 0.0001) and multivariate analysis (p < 0.0001). Furthermore, surface roughness was associated with gene expression related to meniscal degeneration and with tangent modulus which decreases with increasing degeneration (r = - 0.49, p = 0.0002). When meniscal tissue was classified by surface integrity, inflammatory cytokine secretion tended to be higher in severe degenerated menisci. These results suggest that the evaluation of meniscal surface texture could predict the degree of degeneration and inflammatory cytokine secretion.
Collapse
|
16
|
Morejon A, Mantero AMA, Best TM, Jackson AR, Travascio F. Mechanisms of energy dissipation and relationship with tissue composition in human meniscus. Osteoarthritis Cartilage 2022; 30:605-612. [PMID: 35032627 PMCID: PMC8940718 DOI: 10.1016/j.joca.2022.01.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 12/29/2021] [Accepted: 01/03/2022] [Indexed: 02/07/2023]
Abstract
OBJECTIVE The human meniscus is essential in maintaining proper knee joint function. The meniscus absorbs shock, distributes loads, and stabilizes the knee joint to prevent the onset of osteoarthritis. The extent of its shock-absorbing role can be estimated by measuring the energy dissipated by the meniscus during cyclic mechanical loading. METHODS Samples were prepared from the central and horn regions of medial and lateral human menisci from 8 donors (both knees for total of 16 samples). Cyclic compression tests at several compression strains and frequencies yielded the energy dissipated per tissue volume. A GEE regression model was used to investigate the effects of compression, meniscal side and region, and water content on energy dissipation in order to account for repeated measures within samples. RESULTS Energy dissipation by the meniscus increased with compressive strain from ∼0.1 kJ/m3 (at 10% strain) to ∼10 kJ/m3 (at 20% strain) and decreased with loading frequency. Samples from the anterior region provided the largest energy dissipation when compared to central and posterior samples (P < 0.05). Water content for the 16 meniscal tissues was 77.9 (C.I. 72.0-83.8%) of the total tissue mass. A negative correlation was found between energy dissipation and water content (P < 0.05). CONCLUSION The extent of energy dissipated by the meniscus is inversely related to loading frequency and meniscal water content.
Collapse
Affiliation(s)
- Andy Morejon
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL
| | | | - Thomas M. Best
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL,Department of Orthopaedic Surgery, University of Miami, Miami, FL,UHealth Sports Medicine Institute, Coral Gables, FL
| | - Alicia R. Jackson
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL,Corresponding authors: Dr. Francesco Travascio, Associate Professor College of Engineering, University of Miami, 1251 Memorial Drive, MEB 276 Coral Gables, FL 33146 USA Telephone: +1-(305)-284-2371, Dr. Alicia R. Jackson Associate Professor, College of Engineering, University of Miami, 1251 Memorial Drive, MEA 219 Coral Gables, FL 33146, USA, Telephone: +1-(305)-284-2135,
| | - Francesco Travascio
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL,Department of Orthopaedic Surgery, University of Miami, Miami, FL,Max Biedermann Institute for Biomechanics at Mount Sinai Medical Center, Miami Beach, FL,Corresponding authors: Dr. Francesco Travascio, Associate Professor College of Engineering, University of Miami, 1251 Memorial Drive, MEB 276 Coral Gables, FL 33146 USA Telephone: +1-(305)-284-2371, Dr. Alicia R. Jackson Associate Professor, College of Engineering, University of Miami, 1251 Memorial Drive, MEA 219 Coral Gables, FL 33146, USA, Telephone: +1-(305)-284-2135,
| |
Collapse
|
17
|
Berni M, Marchiori G, Cassiolas G, Grassi A, Zaffagnini S, Fini M, Lopomo NF, Maglio M. Anisotropy and inhomogeneity of permeability and fibrous network response in the pars intermedia of the human lateral meniscus. Acta Biomater 2021; 135:393-402. [PMID: 34411754 DOI: 10.1016/j.actbio.2021.08.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 08/10/2021] [Accepted: 08/12/2021] [Indexed: 02/07/2023]
Abstract
Within the human tibiofemoral joint, meniscus plays a key role due to its peculiar time-dependent mechanical characteristics, inhomogeneous structure and compositional features. To better understand the pathophysiological mechanisms underlying this essential component, it is mandatory to analyze in depth the relationship between its structure and the function it performs in the joint. Accordingly, the aim of this study was to evaluate the behavior of both solid and fluid phases of human meniscus in response to compressive loads, by integrating mechanical assessment and histological analysis. Cubic specimens were harvested from seven knee lateral menisci, specifically from anterior horn, pars intermedia and posterior horn; unconfined compressive tests were then performed according to three main loading directions (i.e., radial, circumferential and vertical). Fibril modulus, matrix modulus and hydraulic permeability of the tissue were thence estimated through a fibril-network-reinforced biphasic model. Tissue porosity and collagen fibers arrangement were assessed through histology for each region and related to the loading directions adopted during mechanical tests. Regional and strain-dependent constitutive parameters were finally proposed for the human lateral meniscus, suggesting an isotropic behavior of both the horns, and a transversely isotropic response of the pars intermedia. Furthermore, the histological findings supported the evidences highlighted by the compressive tests. Indeed, this study provided novel insights concerning the functional behavior of human menisci by integrating mechanical and histological characterizations and thus highlighting the key role of this component in knee contact mechanics and presenting fundamental information that can be used in the development of tissue-engineered substitutes. STATEMENT OF SIGNIFICANCE: This work presents an integration to the approaches currently used to model the mechanical behavior of the meniscal tissue. This study assessed in detail the regional and directional contributions of both the meniscal solid and fluid phases during compressive response, providing also complementary histological evidence. Within this updated perspective, both knee computational modeling and meniscal tissue engineering can be improved to have an effective impact on the clinical practice.
Collapse
|
18
|
Seitz AM, Osthaus F, Schwer J, Warnecke D, Faschingbauer M, Sgroi M, Ignatius A, Dürselen L. Osteoarthritis-Related Degeneration Alters the Biomechanical Properties of Human Menisci Before the Articular Cartilage. Front Bioeng Biotechnol 2021; 9:659989. [PMID: 34026741 PMCID: PMC8134692 DOI: 10.3389/fbioe.2021.659989] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Accepted: 03/24/2021] [Indexed: 12/15/2022] Open
Abstract
An exact understanding of the interplay between the articulating tissues of the knee joint in relation to the osteoarthritis (OA)-related degeneration process is of considerable interest. Therefore, the aim of the present study was to characterize the biomechanical properties of mildly and severely degenerated human knee joints, including their menisci and tibial and femoral articular cartilage (AC) surfaces. A spatial biomechanical mapping of the articulating knee joint surfaces of 12 mildly and 12 severely degenerated human cadaveric knee joints was assessed using a multiaxial mechanical testing machine. To do so, indentation stress relaxation tests were combined with thickness and water content measurements at the lateral and medial menisci and the AC of the tibial plateau and femoral condyles to calculate the instantaneous modulus (IM), relaxation modulus, relaxation percentage, maximum applied force during the indentation, and the water content. With progressing joint degeneration, we found an increase in the lateral and the medial meniscal instantaneous moduli (p < 0.02), relaxation moduli (p < 0.01), and maximum applied forces (p < 0.01), while for the underlying tibial AC, the IM (p = 0.01) and maximum applied force (p < 0.01) decreased only at the medial compartment. Degeneration had no influence on the relaxation percentage of the soft tissues. While the water content of the menisci did not change with progressing degeneration, the severely degenerated tibial AC contained more water (p < 0.04) compared to the mildly degenerated tibial cartilage. The results of this study indicate that degeneration-related (bio-)mechanical changes seem likely to be first detectable in the menisci before the articular knee joint cartilage is affected. Should these findings be further reinforced by structural and imaging analyses, the treatment and diagnostic paradigms of OA might be modified, focusing on the early detection of meniscal degeneration and its respective treatment, with the final aim to delay osteoarthritis onset.
Collapse
Affiliation(s)
- Andreas M Seitz
- Institute of Orthopedic Research and Biomechanics, Center of Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
| | - Felix Osthaus
- Institute of Orthopedic Research and Biomechanics, Center of Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
| | - Jonas Schwer
- Institute of Orthopedic Research and Biomechanics, Center of Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
| | - Daniela Warnecke
- Institute of Orthopedic Research and Biomechanics, Center of Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
| | - Martin Faschingbauer
- Department of Orthopedic Surgery, Universitäts- und Rehabilitationskliniken Ulm (RKU), Ulm University Medical Center, Ulm, Germany
| | - Mirco Sgroi
- Department of Orthopedic Surgery, Universitäts- und Rehabilitationskliniken Ulm (RKU), Ulm University Medical Center, Ulm, Germany
| | - Anita Ignatius
- Institute of Orthopedic Research and Biomechanics, Center of Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
| | - Lutz Dürselen
- Institute of Orthopedic Research and Biomechanics, Center of Trauma Research Ulm, Ulm University Medical Center, Ulm, Germany
| |
Collapse
|
19
|
Morejon A, Norberg CD, De Rosa M, Best TM, Jackson AR, Travascio F. Compressive Properties and Hydraulic Permeability of Human Meniscus: Relationships With Tissue Structure and Composition. Front Bioeng Biotechnol 2021; 8:622552. [PMID: 33644008 PMCID: PMC7902918 DOI: 10.3389/fbioe.2020.622552] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 12/21/2020] [Indexed: 12/13/2022] Open
Abstract
The meniscus is crucial in maintaining knee function and protecting the joint from secondary pathologies, including osteoarthritis. The meniscus has been shown to absorb up to 75% of the total load on the knee joint. Mechanical behavior of meniscal tissue in compression can be predicted by quantifying the mechanical parameters including; aggregate modulus (H) and Poisson modulus (ν), and the fluid transport parameter: hydraulic permeability (K). These parameters are crucial to develop a computational model of the tissue and for the design and development of tissue engineered scaffolds mimicking the native tissue. Hence, the objective of this study was to characterize the mechanical and fluid transport properties of human meniscus and relate them to the tissue composition. Specimens were prepared from the axial and the circumferential anatomical planes of the tissue. Stress relaxation tests yielded the H, while finite element modeling was used to curve fit for ν and K. Correlations of moduli with water and glycosaminoglycans (GAGs) content were investigated. On average H was found to be 0.11 ± 0.078 MPa, ν was 0.32 ± 0.057, and K was 2.9 ± 2.27 × 10-15 m4N-1s-1. The parameters H, ν, and K were not found to be statistically different across compression orientation or compression level. Water content of the tissue was 77 ± 3.3% while GAG content was 8.79 ± 1.1%. Interestingly, a weak negative correlation was found between H and water content (R2 ~ 34%) and a positive correlation between K and GAG content (R2 ~ 53%). In conclusion, while no significant differences in transport and compressive properties can be found across sample orientation and compression levels, data trends suggest potential relationships between magnitudes of H and K, and GAG content.
Collapse
Affiliation(s)
- Andy Morejon
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL, United States
| | - Christopher D Norberg
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States
| | - Massimiliano De Rosa
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL, United States
| | - Thomas M Best
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States.,Department of Orthopaedic Surgery, University of Miami, Coral Gables, FL, United States.,UHealth Sports Medicine Institute, Coral Gables, FL, United States
| | - Alicia R Jackson
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, United States
| | - Francesco Travascio
- Department of Mechanical and Aerospace Engineering, University of Miami, Coral Gables, FL, United States.,Department of Orthopaedic Surgery, University of Miami, Coral Gables, FL, United States.,Max Biedermann Institute for Biomechanics at Mount Sinai Medical Center, Miami Beach, FL, United States
| |
Collapse
|
20
|
Schwer J, Rahman MM, Stumpf K, Rasche V, Ignatius A, Dürselen L, Seitz AM. Degeneration Affects Three-Dimensional Strains in Human Menisci: In situ MRI Acquisition Combined With Image Registration. Front Bioeng Biotechnol 2020; 8:582055. [PMID: 33042980 PMCID: PMC7526678 DOI: 10.3389/fbioe.2020.582055] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Accepted: 08/28/2020] [Indexed: 11/20/2022] Open
Abstract
Degenerative changes of menisci contribute to the evolution of osteoarthritis in the knee joint, because they alter the load transmission to the adjacent articular cartilage. Identifying alterations in the strain response of meniscal tissue under compression that are associated with progressive degeneration may uncover links between biomechanical function and meniscal degeneration. Therefore, the goal of this study was to investigate how degeneration effects the three-dimensional (3D; axial, circumferential, radial) strain in different anatomical regions of human menisci (anterior and posterior root attachment; anterior and posterior horn; pars intermedia) under simulated compression. Magnetic resonance imaging (MRI) was performed to acquire image sequences of 12 mild and 12 severe degenerated knee joints under unloaded and loaded [25%, 50% and 100% body weight (BW)] conditions using a customized loading device. Medial and lateral menisci as well as their root attachments were manually segmented. Intensity-based rigid and non-rigid image registration were performed to obtain 3D deformation fields under the respective load levels. Finally, the 3D voxels were transformed into hexahedral finite-element models and direction-dependent local strain distributions were determined. The axial compressive strain in menisci and meniscal root attachments significantly increased on average from 3.1% in mild degenerated joints to 7.3% in severe degenerated knees at 100% BW (p ≤ 0.021). In severe degenerated knee joints, the menisci displayed a mean circumferential strain of 0.45% (mild: 0.35%) and a mean radial strain of 0.41% (mild: 0.37%) at a load level of 100% BW. No significant changes were observed in the circumferential or radial directions between mild and severe degenerated knee joints for all load levels (p > 0.05). In conclusion, high-resolution MRI was successfully combined with image registration to investigate spatial strain distributions of the meniscus and its attachments in response to compression. The results of the current study highlight that the compressive integrity of the meniscus decreases with progressing tissue degeneration, whereas the tensile properties are maintained.
Collapse
Affiliation(s)
- Jonas Schwer
- Institute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Ulm, Germany
| | - Muhammed Masudur Rahman
- Institute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Ulm, Germany.,Department of Mechanical Engineering, University of Connecticut, Storrs, CT, United States
| | - Kilian Stumpf
- Experimental Cardiovascular Imaging, Department of Internal Medicine II, University Hospital Ulm, Ulm, Germany
| | - Volker Rasche
- Experimental Cardiovascular Imaging, Department of Internal Medicine II, University Hospital Ulm, Ulm, Germany
| | - Anita Ignatius
- Institute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Ulm, Germany
| | - Lutz Dürselen
- Institute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Ulm, Germany
| | - Andreas Martin Seitz
- Institute of Orthopaedic Research and Biomechanics, Centre for Trauma Research Ulm, Ulm University Medical Centre, Ulm, Germany
| |
Collapse
|