1
|
Kim DH, Hong JT, Hur JW, Kim IS, Lee HJ, Lee JB. Clinical and Radiological Outcomes in C2 Recapping Laminoplasty for the Pathologies in the Upper Cervical Spine. Neurospine 2024; 21:565-574. [PMID: 38955529 PMCID: PMC11224761 DOI: 10.14245/ns.2347270.635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 01/31/2024] [Accepted: 02/09/2024] [Indexed: 07/04/2024] Open
Abstract
OBJECTIVE To evaluate C2 muscle preservation effect and the radiological and clinical outcomes after C2 recapping laminoplasty. METHODS Fourteen consecutive patients who underwent C2 recapping laminoplasty around C1-2 level were enrolled. To evaluate muscle preservation effect, the authors conducted a morphological measurement of extensor muscles between the operated and nonoperated side. Two surgeons measured the cross-sectional area (CSA) of obliquus capitis inferior (OCI) and semispinalis cervicis (SSC) muscle before and after surgery to determine atrophy rates (ARs). Additionally, we examined range of motion (ROM), sagittal vertical axis (SVA), neck visual analogue scale (VAS), Neck Disability Index (NDI), and Japanese Orthopaedic Association (JOA) score to assess potential changes in alignment and consequent clinical outcomes following posterior cervical surgery. RESULTS We measured the CSA of OCI and SSC before surgery, and at 6 and 12 months postoperatively. Based on these measurements, the AR of the nonoperated SSC was 0.1% ± 8.5%, the AR of the operated OCI was 2.0% ± 7.2%, and the AR of the nonoperated OCI was -0.7% ± 5.1% at the 12 months after surgery. However, the AR of the operated side's SSC was 11.2% ± 12.5%, which is a relatively higher value than other measurements. Despite the atrophic change of SSC on the operated side, there were no prominent changes observed in SVA, C0-2 ROM, and C2-7 ROM between preoperative and 12 months postoperative measurements, which were 11.8 ± 10.9 mm, 16.3° ± 5.9°, and 48.7° ± 7.7° preoperatively, and 14.1 ± 11.6 mm, 16.1° ± 7.2°, and 44.0° ± 10.3° at 12 months postoperative, respectively. Improvement was also noted in VAS, NDI, and JOA scores after surgery with JOA recovery rate of 77.3% ± 29.6%. CONCLUSION C2 recapping laminoplasty could be a useful tool for addressing pathologies around the upper cervical spine, potentially mitigating muscle atrophy and reducing postoperative neck pain, while maintaining sagittal alignment and ROM.
Collapse
Affiliation(s)
- Dong Hun Kim
- Department of Neurosurgery, Eunpyeong St. Mary’s Hospital, The Catholic University of Korea, Seoul, Korea
| | - Jae Taek Hong
- Department of Neurosurgery, Eunpyeong St. Mary’s Hospital, The Catholic University of Korea, Seoul, Korea
| | - Jung Woo Hur
- Department of Neurosurgery, Eunpyeong St. Mary’s Hospital, The Catholic University of Korea, Seoul, Korea
| | - Il Sup Kim
- Department of Neurosurgery, St. Vincent Hospital, The Catholic University of Korea, Suwon, Korea
| | - Ho Jin Lee
- Department of Neurosurgery, St. Vincent Hospital, The Catholic University of Korea, Suwon, Korea
| | - Jong Beom Lee
- Department of Neurosurgery, Chungbuk National University Hospital, Cheongju, Korea
| |
Collapse
|
2
|
Lee SH, Park JH, Lee JB, Lee HJ, Kim IS, Hur JW, Hong JT. Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation-A Retrospective Comparison with Conventional Pedicle Screw Implantation. Global Spine J 2023; 13:1592-1601. [PMID: 35193407 PMCID: PMC10448084 DOI: 10.1177/21925682211041965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
STUDY DESIGN A Retrospective Cohort Study. OBJECTIVE To introduce a new Doppler sonography-assisted pedicle screw fixation technique that enables vertebral artery (VA) monitoring during surgery and compares the accuracies of Doppler sonography-assisted cervical pedicle screw fixation and the conventional technique. METHODS This retrospective study was performed on 164 consecutive patients that underwent pedicle-based screw fixation from C2 to C6 between January 2013 and August 2020. Surgery was performed without intraoperative Doppler sonography in 84 cases (the Control group) or with intraoperative Doppler sonography in 80 cases (the Doppler group). Proper positioning of pedicle screws was graded, and the incidences of VA injury and screw breach in the Control and Doppler groups were compared. RESULTS Three hundred and ninety-nine screws were placed in the 164 patients (Doppler, 186 screws; Control, 213 screws). The percentages of well-positioned screws in the two groups were significantly different (Doppler, 97.8%; Control, 85.0%). There were two cases of VA injury in the Control group, an incidence of 2.4%, but no case in the Doppler group. CONCLUSION Doppler sonography can be used intraoperatively to help guide the trajectory of the cervical pedicle screw insertion. It can detect the VA inside the screw trajectory and may reduce the risk of VA injury during cervical pedicle screw fixation.
Collapse
Affiliation(s)
- Sang Hyo Lee
- Department of Neurosurgery, The Catholic University of Korea Eunpyeong St Mary’s Hospital, Eunpyeong-gu, Korea
| | - Jong-Hyeok Park
- Department of Neurosurgery, The Catholic University of Korea Incheon St Mary’s Hospital, Incheon, Korea
| | - Jong Beom Lee
- Department of Neurosurgery, Chungbuk National University, Cheongju, Korea
| | - Ho Jin Lee
- Department of Neurosurgery, The Catholic University of Korea St Vincent’s Hospital, Suwon, Korea
| | - Il Sup Kim
- Department of Neurosurgery, The Catholic University of Korea St Vincent’s Hospital, Suwon, Korea
| | - Jeong Woo Hur
- Department of Neurosurgery, The Catholic University of Korea Eunpyeong St Mary’s Hospital, Eunpyeong-gu, Korea
| | - Jae Taek Hong
- Department of Neurosurgery, The Catholic University of Korea Eunpyeong St Mary’s Hospital, Eunpyeong-gu, Korea
- Department of Neurosurgery, The Catholic University of Korea St Vincent’s Hospital, Suwon, Korea
| |
Collapse
|
3
|
De Abreu Pineda M, Atallah E, Wainwright J, Schaefer J, Mahtabfar A, Harrop J, Prasad S, Heller J, Sharan A, Sivaganesan A, Jallo J. Hypoglossal nerve injury with C1 lateral mass screw placement: A case report and review of the literature. Radiol Case Rep 2022; 17:4594-4598. [PMID: 36193267 PMCID: PMC9525811 DOI: 10.1016/j.radcr.2022.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 08/29/2022] [Accepted: 09/04/2022] [Indexed: 11/16/2022] Open
Affiliation(s)
- Maria De Abreu Pineda
- Sidney Kimmel Medical College at Thomas Jefferson University, 1025 Walnut St #100, Philadelphia, PA 19107, USA
- Corresponding author.
| | - Elias Atallah
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| | - John Wainwright
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| | - Joseph Schaefer
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| | - Aria Mahtabfar
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| | - James Harrop
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| | - Srinivas Prasad
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| | - Joshua Heller
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| | - Ashwini Sharan
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| | - Ahilan Sivaganesan
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| | - Jack Jallo
- Thomas Jefferson University Hospital, Department of Neurological Surgery, 111 S 11th St, Philadelphia, PA 19107, USA
| |
Collapse
|
4
|
Hong JT, Koller H, Abumi K, Yuan W, Falavigna A, Lee HJ, Lee JB, Le Huec JC, Park JH, Kim IS. A new nomenclature system for the surgical treatment of cervical spine deformity, developing, and validation of SOF system. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2021; 30:1670-1680. [PMID: 33547943 DOI: 10.1007/s00586-021-06751-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 12/08/2020] [Accepted: 01/23/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE To develop and assess the reliability of new nomenclature system that systematically organizes osteotomy techniques and briefly describes the surgical approach, the surgical sequence, and the fixation technique for cervical spine deformity (CSD). METHODS We developed a new classification system (SOF system) for CSD surgery that describes the sequence of surgical approach (S), the grade of osteotomy (O), and the information of fixation (F) using alphanumeric codes. Twenty CSD osteotomies (8 anterior osteotomies, 12 posterior osteotomies) were included in this study to evaluate the inter- and intra-observer agreement based on operation records. Six observers performed independent evaluations of the operation records in random order. Each observer described 20 CSD surgeries using the SOF system twice (> 30 days between assessments) based on operation records to validate SOF system. RESULTS Overall agreement (among all six observers at the initial assessment) on the anterior and posterior osteotomy was ICC = 0.96 and ICC = 0.91, respectively. Overall agreement (repeat observations after at least 30 days) on the anterior and posterior osteotomy was ICC = 0.96 and ICC = 0.91, respectively. This data showed that both inter- and intra-observer agreement revealed 'excellent'. CONCLUSION This study introduces the SOF system of the CSD surgery to understand the surgical sequence, the type of osteotomy and the fixation techniques. The investigation of the inter- and intra-observer agreement revealed 'excellent agreement' for both anterior and posterior osteotomies. Thus, SOF system can provide a consistent description of the various CSD surgeries and its use will provide a common frame for CSD surgery and help communicate between surgeons.
Collapse
Affiliation(s)
- Jae Taek Hong
- Department of Neurosurgery, Eunpyeong St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea.
| | - Heiko Koller
- Department of Neurosurgery, Technical University of Munich, Munich, Germany
| | - Kuniyoshi Abumi
- Department of Orthopedic Surgery, Sapporo Orthopedic Hospital, Sapporo, Japan
| | - Wen Yuan
- Department of Orthopedic Surgery, Changzheng Hospital, Second Military Medical University, Shanghai, China
| | - Asdrubal Falavigna
- Department of Neurosurgery, University of Caxias Do Sul, Caxias Do Sul, RS, Brazil
| | - Ho Jin Lee
- Department of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Suwon, Korea
| | - Jong Beom Lee
- Department of Neurosurgery, Chungbuk National University Hospital, Cheongju, Korea
| | - Jean-Charles Le Huec
- Department of Orthopedic Surgery, Bordeaux University Hospital, Bordeaux, France
| | - Jong-Hyeok Park
- Department of Neurosurgery, Incheon St. Mary's Hospital, The Catholic University of Korea, Incheon, Korea
| | - Il Sup Kim
- Department of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Suwon, Korea
| |
Collapse
|
5
|
Hong JT, Koller H, Abumi K, Yuan W, Falavigna A, Lee HJ, Lee JB, Le Huec JC, Park JH, Kim IS. SOF System; A New Nomenclature System for the Surgical Techniques of Cervical Spine Deformity. Neurospine 2020; 17:505-512. [PMID: 33022155 PMCID: PMC7538365 DOI: 10.14245/ns.2040472.236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 08/25/2020] [Indexed: 12/05/2022] Open
Abstract
Although cervical spinal deformity (CSD) can have a profoundly negative impact on an individual’s quality of life and there have been many advances in surgical treatment of CSD in recent years, there exists no comprehensive classification system of surgical treatment that categorizes anterior and posterior surgery separately according to the grade of surgery. The objective of this study is to introduce the new classification system of various surgical treatments for CSD. We developed a new classification system (SOF system) for CSD surgery that describes the sequence of surgical approach (S), the grade of osteotomy (O), and the information of fixation (F) using alphanumeric codes. This new classification system can provide a consistent description of the various osteotomies performed in CSD surgery. Especially, regarding research, there has been a clear benefit to this classification. Having a standardized classification that allows for common frame for cervical deformity correction surgery, communication between surgeons and the evaluation of the CSD surgeries make it possible to conduct global comparative research about surgical outcome.
Collapse
Affiliation(s)
- Jae Taek Hong
- Department of Neurosurgery, Eunpyeong St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea
| | - Heiko Koller
- Department of Neurosurgery, Technical University of Munich, Munich, Germany
| | - Kuniyoshi Abumi
- Department of Orthopedic Surgery, Sapporo Orthopedic Hospital, Sapporo, Japan
| | - Wen Yuan
- Department of Orthopedic Surgery, Changzheng Hospital, Second Military Medical University, Shanghai, China
| | - Asdrubal Falavigna
- Department of Neurosurgery, University of Caxias do Sul, Caxias do Sul, RS, Brazil
| | - Ho Jin Lee
- Department of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Suwon, Korea
| | - Jong Beom Lee
- Department of Neurosurgery, Chungbuk National University Hospital, Cheongju, Korea
| | - Jean-Charles Le Huec
- Department of Orthopedic Surgery, Bordeaux University Hospital, Bordeaux, France
| | - Jong Hyuk Park
- Department of Neurosurgery, Incheon St. Mary's Hospital, The Catholic University of Korea, Incheon, Korea
| | - Il Sup Kim
- Department of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Suwon, Korea
| |
Collapse
|