1
|
Alrasheed SH, Aldakhil S. Corneal Curvature, Anterior Chamber Depth, Lens Thickness, And Vitreous Chamber Depth: Their Intercorrelations With Refractive Error In Saudi Adults. Open Ophthalmol J 2022. [DOI: 10.2174/18743641-v16-e2209300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background:
Ocular biometrics, such as corneal curvature, axial length, anterior chamber depth, and lens thickness, play a significant role in the development of refractive error and are essential in many clinical and research applications.
Objective:
To determine means and ranges for corneal curvature, axial length, anterior chamber depth, lens thickness, vitreous chamber depth, and their intercorrelations with refractive error in Saudi adults.
Methods:
A total of 120 eyes of 60 hyperopic and 60 myopic subjects aged 19-26 years old were enrolled in this comparative cross-sectional study. Axial Length (AL), Anterior Chamber Depth (ACD), Lens Thickness (LT), and Vitreous Chamber Depth (VCD) were measured by the SONOMED ultrasound E-Z SCAN AB5500+, A-scan, with a contact technique. An ophthalmometer measured the refractive status objectively by auto-refraction and the corneal radius of curvature.
Results:
The findings showed that the myopic eyes had a deeper ACD(3.70±0.27mm) than hyperopic eyes (3.28±0.32mm), P=0.0001. However, the hyperopic eyes had a thicker LT (3.84±0.24mm) than the myopic eyes (3.81±0.19mm), P=0.640. The mean of the corneal radius of curvature for the myopic eyes was slightly more curved (7.87±0.23mm) than for the hyperopic eyes (7.95±0.27mm), P=0.602. The myopic eyes had a higher axial length/corneal radius AL/CR ratio (3.12±0.11) than hyperopic eyes (2.89±0.06), with P=0.0001. Myopic spherical equivalent (SPH) positively correlated with VCD and AL/CR ratio, P=0.0001. Vitreous chamber depth/Axial length ratio (VCD/AL) in the myopic eyes was higher (0.693±0.041) than in the hyperopic eyes (0.677±0.018), P=0.000. Hyperopic SPH was positively associated with the VCD/AL ratio, P=0.0001.
Conclusion:
Myopic eyes had a deeper VCD than hyperopic eyes; there was a strong positive correlation between VCD and myopic SPH. There was a strong positive correlation between the AL/CR ratio and myopic SPH and a VCD/AL ratio and the hyperopic SPH. Thus, the study suggests the possible utility of the AL/CR ratio while assessing the development of myopic refractive error and the VCD/AL ratio when evaluating hyperopic eyes and their associated complications.
Collapse
|
2
|
Tang C, Wu Q, Liu B, Wu G, Fan J, Hu Y, Yu H. A Multicenter Study of the Distribution Pattern of Posterior-To-Anterior Corneal Curvature Radii Ratio in Chinese Myopic Patients. Front Med (Lausanne) 2021; 8:724674. [PMID: 34988088 PMCID: PMC8720933 DOI: 10.3389/fmed.2021.724674] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 11/29/2021] [Indexed: 11/13/2022] Open
Abstract
Estimation of corneal refractive power (CRP) is of crucial importance to refractive and cataract surgery. The ratio of posterior to anterior curvature radii of the cornea (P/A ratio) is one of the key factors to determine the actual CRP (True-K). While the traditional method to calculate the CRP (Sim-K) is based on a constant P/A ratio (0.82), it is suggested that the P/A ratio varies in different people and exhibits a distribution pattern, which may have an impact on the accuracy of CRP estimation and postoperative refractive outcome. In this multicenter study, we aimed to investigate the distribution pattern of the P/A ratio in a large number of myopic patients, and further explore the relationship between P/A ratio and ΔK (the difference between True-K and Sim-K). We found that distribution of the P/A ratio ranged from 0.72 to 0.86 with an average value of 0.82 ± 0.01. The compensation effect of the refractive power of the posterior on the anterior surface of the cornea decreased with the increase of P/A ratio. There was a significant correlation between P/A ratio and ΔK in all eyes (r = 0.9764, P < 0.0001). A change of 0.1 in P/A ratio could cause a change of 0.75 D in ΔK. Our study suggests that the actual P/A ratio should be taken into consideration in refractive and cataract surgery when calculating the CRP and power of the intraocular lens in eyes with significantly deviated P/A ratios.
Collapse
Affiliation(s)
- Changting Tang
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
- Affiliated Hospital of Guilin Medical University, Guilin, China
| | - Qiaowei Wu
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Baoyi Liu
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Guanrong Wu
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| | - Jing Fan
- Affiliated Hospital of Guilin Medical University, Guilin, China
| | - Yijun Hu
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
- Refractive Surgery Center, Aier Institute of Refractive Surgery, Guangzhou Aier Eye Hospital, Guangzhou, China
- Aier School of Ophthalmology, Central South University, Changsha, China
| | - Honghua Yu
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
| |
Collapse
|
3
|
Yuan B, Li J, Song H. Effect of misalignment at different orientations associated with angle κ on optical performance of aspheric intraocular lenses with different surface designs. APPLIED OPTICS 2021; 60:5917-5924. [PMID: 34263818 DOI: 10.1364/ao.423000] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 06/22/2021] [Indexed: 06/13/2023]
Abstract
Intraocular lens (IOL) misalignment and angle κ have had significant negative impact on post-operative quality of vision. ZEMAX software has been used to imitate the optical performance of pseudophakic eyes with different IOL surface designs at different orientations of IOL misalignment (decentration of 0.4 mm and tilt of 7°, and with the existence of 0.5 mm angle κ). We found that an aspheric balanced curve optic surface maintained better optical performance via inducing less coma aberration. Coma aberration played an unexpectedly important role in the optical performance. With angle κ, the impact of IOL misalignment on visual quality was associated with the orientation of decentration and tilt, indicating that the coma compensation also took effect in pseudophakic eyes. Due to the high incidence of post-operative IOL misalignment, our results provide evidence of the importance of considering personalized angle κ before cataract surgery for patients.
Collapse
|