1
|
Chavarria-Bolanos D, Komabayashi T, Shen I, Vega-Baudrit J, Gandolfi MG, Prati C, Montero-Aguilar M. Effects of heat on seven endodontic sealers. J Oral Sci 2021; 64:33-39. [PMID: 34880145 DOI: 10.2334/josnusd.21-0178] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
PURPOSE To examine the microscopic surface features, chemical composition, and thermodynamic profile of seven endodontic sealers (AH Plus, Adseal, MTA-Fillapex, RoekoSeal, GuttaFlow 2, GuttaFlow BioSeal, and EndoRez) exposed to high-temperature changes using an endodontic obturation device. METHODS The thermal properties were examined using scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Then, six disc-shaped specimens of each sealer were prepared and divided into two groups - a room temperature group and a heat exposure group - for analysis of surface and chemical changes using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). RESULTS DSC analysis showed that AH Plus had the highest exothermal signal (122.9°C), while TGA analysis showed that MTA-Fillapex was most affected by increased temperature (32.4% mass loss at 230ºC). SEM analysis showed that while AH Plus and GuttaFlow BioSeal maintained their surface integrity after heat exposure, the EDS profiles demonstrated changes in the chemical composition of the sealers after heat exposure for 5 s. High-temperature exposure had a negative impact on the properties of five of the sealers (Adseal, MTA-Fillapex, RoekoSeal, GuttaFlow 2, and EndoRez). CONCLUSION AH Plus and GuttaFlow BioSeal showed minimal changes upon high-temperature exposure, suggesting their suitability for thermal endodontic obturation techniques.
Collapse
Affiliation(s)
| | | | - Ivy Shen
- College of Dental Medicine, University of New England
| | | | - Maria G Gandolfi
- Laboratory of Biomaterials and Oral Pathology, School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna
| | - Carlo Prati
- Endodontic Clinical Section, School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna
| | | |
Collapse
|
2
|
Ochoa-RodrÍguez VM, Wilches-Visbal JH, Roma B, Coaguila-Llerena H, Tanomaru-Filho M, GonÇalves A, Spin-Neto R, Faria G. Radiopacity of endodontic materials using two models for conversion to millimeters of aluminum. Braz Oral Res 2020; 34:e080. [PMID: 32696910 DOI: 10.1590/1807-3107bor-2020.vol34.0080] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Accepted: 04/20/2020] [Indexed: 11/22/2022] Open
Abstract
The aims of the present study were to compare conventional radiography, radiographs digitized with a scanner or photographic camera, and digital radiography, used to evaluate the radiopacity of endodontic materials, and to compare the accuracy of linear and quadratic models used to convert radiopacity values to equivalent millimeters of aluminum (mm Al). Specimens of AH Plus, Endofill, Biodentine and BioMTA materials (n = 8) were radiographed next to an aluminum step-wedge using radiographic films and digital radiography systems (FONA CMOS sensor, Kodak CMOS sensor and photosensitive phosphor plate-PSP). Conventional radiographs were digitized using a scanner or photographic digital camera. Digital images of all the radiographic systems were evaluated using dedicated software. Optical density units (ODU) of the specimens and the aluminum step-wedge were evaluated by a photo-densitometer (PTDM), used in conventional radiographs. The radiopacity in equivalent mm Al of the materials was determined by linear and quadratic models, and the coefficients of determination (R2) values were calculated for each model. Radiopacity of the materials ranged from -9% to 25% for digital systems and digitized radiographs, compared to the PTDM (p < 0.05). The R2 values of the quadratic model were higher than those of the linear model. In conclusion, the FONA CMOS sensor showed the lowest radiopacity variability of the methodologies used, compared with the PTDM, except for the BioMTA group (higher than PTDM). The quadratic model showed higher R2 values than the linear model, thus indicating better accuracy and possible adoption to evaluate the radiopacity of endodontic materials.
Collapse
Affiliation(s)
- Victor Manuel Ochoa-RodrÍguez
- Department of Restorative Dentistry, Araraquara School of Dentistry, Universidade Estadual Paulista, Araraquara, SP, Brazil
| | | | - Barbara Roma
- Department of Restorative Dentistry, Araraquara School of Dentistry, Universidade Estadual Paulista, Araraquara, SP, Brazil
| | - Hernán Coaguila-Llerena
- Department of Restorative Dentistry, Araraquara School of Dentistry, Universidade Estadual Paulista, Araraquara, SP, Brazil
| | - Mário Tanomaru-Filho
- Department of Restorative Dentistry, Araraquara School of Dentistry, Universidade Estadual Paulista, Araraquara, SP, Brazil
| | - Andréa GonÇalves
- Department of Oral Diagnosis and Surgery, Araraquara School of Dentistry, Universidade Estadual Paulista, Araraquara, SP, Brazil
| | - Rubens Spin-Neto
- Department of Dentistry and Oral Health, School of Health, Aarhus University, Aarhus, Denmark
| | - Gisele Faria
- Department of Restorative Dentistry, Araraquara School of Dentistry, Universidade Estadual Paulista, Araraquara, SP, Brazil
| |
Collapse
|
3
|
Ekici MA, Ömürlü H. In vitro comparison of the physical properties of zinc oxide eugenol-based, propolis-containing experimental root canal sealers with standard sealers. ACTA ODONTOLOGICA TURCICA 2019. [DOI: 10.17214/gaziaot.440060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
4
|
Lopes FC, Zangirolami C, Mazzi-Chaves JF, Silva-Sousa AC, Crozeta BM, Silva-Sousa YTC, Sousa-Neto MD. Effect of sonic and ultrasonic activation on physicochemical properties of root canal sealers. J Appl Oral Sci 2019; 27:e20180556. [DOI: 10.1590/1678-7757-2018-0556] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Accepted: 02/17/2019] [Indexed: 11/21/2022] Open
|
5
|
Physicochemical Properties of Epoxy Resin-Based and Bioceramic-Based Root Canal Sealers. Bioinorg Chem Appl 2017; 2017:2582849. [PMID: 28210204 PMCID: PMC5292198 DOI: 10.1155/2017/2582849] [Citation(s) in RCA: 84] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Accepted: 12/08/2016] [Indexed: 11/26/2022] Open
Abstract
Three bioceramic sealers (EndoSequence BC sealer, EndoSeal MTA, and MTA Fillapex) and three epoxy resin-based sealers (AH-Plus, AD Seal, and Radic-Sealer) were tested to evaluate the physicochemical properties: flow, final setting time, radiopacity, dimensional stability, and pH change. The one-way ANOVA and Tukey's post hoc test were used to analyze the data (P = 0.05). The MTA Fillapex sealer had a highest flow and the BC Sealer presented a flow significantly lower than the others (P < 0.05). The BC Sealer and MTA Fillapex samples were not set in humid incubator condition even after one month. EndoSeal MTA had the longest setting time among the measurable materials and Radic-Sealer and AD Seal showed shorter setting time than the AH-Plus (P < 0.05). AH-Plus and EndoSeal MTA showed statistically higher values and MTA Fillapex showed statistically lower radiopacity (P < 0.05). BC Sealer showed the highest alkaline pH in all evaluation periods. Set samples of 3 epoxy resin-based sealers and EndoSeal MTA presented a significant increase of pH over experimental time for 4 weeks. In conclusion, the bioceramic sealer and epoxy resin-based sealers showed clinical acceptable physicochemical properties, but BC Sealer and MTA Fillapex were not set completely.
Collapse
|
6
|
Gandolfi M, Siboni F, Prati C. Properties of a novel polysiloxane-guttapercha calcium silicate-bioglass-containing root canal sealer. Dent Mater 2016; 32:e113-26. [DOI: 10.1016/j.dental.2016.03.001] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Accepted: 03/01/2016] [Indexed: 11/29/2022]
|
7
|
Influence of Ultrasonic Activation of 4 Root Canal Sealers on the Filling Quality. J Endod 2014; 40:964-8. [DOI: 10.1016/j.joen.2013.11.016] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Revised: 11/20/2013] [Accepted: 11/21/2013] [Indexed: 11/17/2022]
|
8
|
Radiopacity and Cytotoxicity of Portland Cement Containing Zirconia Doped Bismuth Oxide Radiopacifiers. J Endod 2014; 40:251-4. [DOI: 10.1016/j.joen.2013.07.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2013] [Revised: 07/19/2013] [Accepted: 07/20/2013] [Indexed: 11/19/2022]
|
9
|
An SY, Lee DH, Lee KB. Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography. ACTA ACUST UNITED AC 2013. [DOI: 10.14368/jdras.2013.29.4.377] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
10
|
Altintas SH, Yildirim T, Kayipmaz S, Usumez A. Evaluation of the radiopacity of luting cements by digital radiography. J Prosthodont 2012; 22:282-6. [PMID: 23107317 DOI: 10.1111/j.1532-849x.2012.00936.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/11/2012] [Indexed: 11/28/2022] Open
Abstract
PURPOSE The aim of this study was to evaluate the radiopacity of eight contemporary luting cements using direct digital radiography. MATERIALS AND METHODS Ten specimens, (5 mm diameter, 1 mm high) were prepared for each material tested (RelyX ARC, RelyX U100, RelyX Unicem, Nexus 2, Nexus 3, Metacem, Breeze, Adhesor zinc phosphate). The specimens were stored in a moist chamber at 37°C until completely set, then radiographed using a Kodak digital sensor and an aluminum step wedge with variable thicknesses (1 to 13 mm in 1-mm increments) used for reference. A Kodak 2100 intraoral X-ray unit was operated at 60 kV, 7 mA, and 0.20 seconds. According to international standards, the radiopacity of the specimens was compared with that of the aluminum step wedge using the equal-density area tool of the Kodak Dental Imaging software (ver. 6.7). Data were analyzed by ANOVA and Tukey's test. RESULTS Adhesor zinc phosphate cement showed the highest radiopacity of all materials and dentin. Breeze showed the lowest radiopacity (p < 0.05). No significant difference in radiopacity was observed between dentin and RelyX ARC, Nexus 2, or Metacem (p > 0.05). The radiopacities of Nexus 3 and RelyX Unicem were significantly higher than those of other resin cements and dentin (p < 0.05). CONCLUSIONS All materials showed radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association. Breeze had less radiopacity than dentin.
Collapse
Affiliation(s)
- Subutay Han Altintas
- Department of Prosthodontics, Faculty of Dentistry, Karadeniz Technical University, Trabzon 61080, Turkey.
| | | | | | | |
Collapse
|
11
|
Poorsattar Bejeh Mir A, Poorsattar Bejeh Mir M. Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge. Imaging Sci Dent 2012; 42:163-7. [PMID: 23071966 PMCID: PMC3465758 DOI: 10.5624/isd.2012.42.3.163] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Revised: 06/15/2012] [Accepted: 07/23/2012] [Indexed: 11/24/2022] Open
Abstract
Purpose ANSI/ADA has established standards for adequate radiopacity. This study was aimed to assess the changes in radiopacity of composite resins according to various tube-target distances and exposure times. Materials and Methods Five 1-mm thick samples of Filtek P60 and Clearfil composite resins were prepared and exposed with six tube-target distance/exposure time setups (i.e., 40 cm, 0.2 seconds; 30 cm, 0.2 seconds; 30 cm, 0.16 seconds, 30 cm, 0.12 seconds; 15 cm, 0.2 seconds; 15 cm, 0.12 seconds) performing at 70 kVp and 7 mA along with a 12-step aluminum stepwedge (1 mm incremental steps) using a PSP digital sensor. Thereafter, the radiopacities measured with Digora for Windows software 2.5 were converted to absorbencies (i.e., A=-log (1-G/255)), where A is the absorbency and G is the measured gray scale). Furthermore, the linear regression model of aluminum thickness and absorbency was developed and used to convert the radiopacity of dental materials to the equivalent aluminum thickness. In addition, all calculations were compared with those obtained from a modified 3-step stepwedge (i.e., using data for the 2nd, 5th, and 8th steps). Results The radiopacities of the composite resins differed significantly with various setups (p<0.001) and between the materials (p<0.001). The best predicted model was obtained for the 30 cm 0.2 seconds setup (R2=0.999). Data from the reduced modified stepwedge was remarkable and comparable with the 12-step stepwedge. Conclusion Within the limits of the present study, our findings support that various setups might influence the radiopacity of dental materials on digital radiographs.
Collapse
Affiliation(s)
- Arash Poorsattar Bejeh Mir
- Dentistry Student Research Committee (DSRC), Dental Materials Research Center, Dentistry School, Babol University of Medical Sciences, Babol, Iran
| | | |
Collapse
|
12
|
Baldi JV, Bernardes RA, Duarte MAH, Ordinola-Zapata R, Cavenago BC, Moraes JCS, de Moraes IG. Variability of physicochemical properties of an epoxy resin sealer taken from different parts of the same tube. Int Endod J 2012; 45:915-20. [DOI: 10.1111/j.1365-2591.2012.02049.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
13
|
Akcay I, Ilhan B, Dundar N. Comparison of conventional and digital radiography systems with regard to radiopacity of root canal filling materials. Int Endod J 2012; 45:730-6. [DOI: 10.1111/j.1365-2591.2012.02026.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
14
|
Marciano MA, Guimarães BM, Ordinola-Zapata R, Bramante CM, Cavenago BC, Garcia RB, Bernardineli N, Andrade FB, Moraes IG, Duarte MA. Physical Properties and Interfacial Adaptation of Three Epoxy Resin–based Sealers. J Endod 2011; 37:1417-21. [DOI: 10.1016/j.joen.2011.06.023] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2011] [Revised: 06/22/2011] [Accepted: 06/23/2011] [Indexed: 11/15/2022]
|
15
|
Collares FM, Leitune VCB, Rostirolla FV, Trommer RM, Bergmann CP, Samuel SMW. Nanostructured hydroxyapatite as filler for methacrylate-based root canal sealers. Int Endod J 2011; 45:63-7. [DOI: 10.1111/j.1365-2591.2011.01948.x] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
16
|
Flores DSH, Rached-Júnior FJA, Versiani MA, Guedes DFC, Sousa-Neto MD, Pécora JD. Evaluation of physicochemical properties of four root canal sealers. Int Endod J 2010; 44:126-35. [DOI: 10.1111/j.1365-2591.2010.01815.x] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
17
|
Resende LM, Rached-Junior FJA, Versiani MA, Souza-Gabriel AE, Miranda CES, Silva-Sousa YTC, Sousa Neto MD. A comparative study of physicochemical properties of AH Plus, Epiphany, and Epiphany SE root canal sealers. Int Endod J 2009; 42:785-93. [DOI: 10.1111/j.1365-2591.2009.01584.x] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|