1
|
Karaca Sakallı A, Ekici MA. Evaluation of shaping ability, apical transportation and centering ratio of T-Endo Must, WaveOne Gold, and Trunatomy in resin blocks. PeerJ 2024; 12:e18088. [PMID: 39421425 PMCID: PMC11485059 DOI: 10.7717/peerj.18088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Accepted: 08/22/2024] [Indexed: 10/19/2024] Open
Abstract
Purpose This study aimed to compare the shaping abilities of different nickel-titanium file systems. Materials and Methods Sixty-six j-shaped resin blocks were randomly divided into three groups (n = 22): Group T-Endo MUST (TE), Group WaveOne (W), Group TruNatomy (TR). After canal preparation, the amount of material removed from the canal, the centering ratio of the file systems, the direction and amount of canal transportation, and shaping errors were evaluated. Shaping time was calculated. Data of shaping time were analyzed with ANOVA and Tamhane test. Data on the shaping ability were analyzed with two- and three-way ROBUST ANOVA. The significance level was set at p = 0.05. Results There was a statistically significant difference between all groups for shaping time (p < 0.001). There was a statistically significant difference between groups for the total amount of material removed (p < 0.001). The directions of canal transportation were the inner surface of the curvature for W and TR and the outer for TE. There was no statistically significant difference between the groups for the amount of transportation (p > 0.05). The centering ratio of TE and W was statistically higher than TruNatomy (p < 0.001). Conclusions TruNatomy removed the least material that supported the minimally invasive endodontic approach. All file systems caused similar transportation and did not change the original canal shape.
Collapse
Affiliation(s)
- Aybüke Karaca Sakallı
- Faculty of Dentistry, Deparment of Endodontics, Gazi University Ankara, Ankara, Turkey
| | - Mügem Aslı Ekici
- Faculty of Dentistry, Deparment of Endodontics, Gazi University Ankara, Ankara, Turkey
| |
Collapse
|
2
|
Martins JNR, Silva EJNL, Marques D, Versiani MA. Influence of Continuous Rotation and Optimal Torque Reverse Kinematics on the Cyclic Fatigue Strength of Endodontic NiTi Clockwise Cutting Rotary Instruments. Dent J (Basel) 2024; 12:317. [PMID: 39452445 PMCID: PMC11506770 DOI: 10.3390/dj12100317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2024] [Revised: 09/24/2024] [Accepted: 09/29/2024] [Indexed: 10/26/2024] Open
Abstract
Objectives: The objective of the present study was to evaluate the cyclic fatigue strength of clockwise cutting rotary endodontic instruments when subjected to two different kinematics: continuous clockwise rotation and clockwise reciprocation movement under optimum torque reverse (OTR) motion. Methods: New ProTaper Next X1 (n = 20) and X2 (n = 20) instruments were randomly divided into two subgroups (n = 10) based on kinematics (continuous rotation or OTR). The specimens were tested using a custom-made device with a non-tapered stainless-steel artificial canal measuring 19 mm in length, featuring a 6 mm radius and an 86-degree curvature. All instruments were tested with a lubricant at room temperature until a fracture occurred. The time to fracture and the length of the separated fragment were recorded. Subsequently, the fractured instruments were inspected under a scanning electron microscope for signs of cyclic fatigue failure, plastic deformation, and/or crack propagation. The subgroup comparisons for time to fracture and instrument length were performed using the independent samples t-test, with the level of statistical significance set at 0.05. Results: When using OTR movement, the ProTaper Next X1 increased the time to fracture from 52.9 to 125.8 s (p < 0.001), while the ProTaper Next X2 increased from 45.4 to 66.0 s (p < 0.001). No subgroup exhibited plastic deformations, but both showed dimpling marks indicative of cyclic fatigue as the primary mode of failure. Additionally, OTR movement resulted in more metal alloy microcracks. Conclusions: The use of OTR motion extended the lifespan of the tested instruments and resulted in a higher number of metal microcracks. This suggests that OTR motion helped to distribute the mechanical stress more evenly across the instrument, thereby relieving localized tension. As a result, it delayed the formation of a single catastrophic crack, enhancing the overall performance of the instruments during the experimental procedures.
Collapse
Affiliation(s)
- Jorge N. R. Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral (GIBBO), Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudos de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
| | - Emmanuel J. N. L. Silva
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro 21210-623, Brazil
- Department of Endodontics, Fluminense Federal University, Rio de Janeiro 24220-900, Brazil
- Department of Endodontics, Rio de Janeiro University (UERJ), Rio de Janeiro 20550-013, Brazil
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral (GIBBO), Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudos de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
| | - Marco A. Versiani
- Dental Specialty Center, Brazilian Military Police, Belo Horizonte 30350-190, Brazil
| |
Collapse
|
3
|
Călin C, Focșăneanu AM, Paulsen F, Didilescu AC, Niță T. Shaping Efficiency of Rotary and Reciprocating Kinematics of Engine-driven Nickel-Titanium Instruments in Moderate and Severely curved Root Canals Using Microcomputed Tomography: A Systematic Review of Ex Vivo Studies. J Endod 2024; 50:907-924. [PMID: 38537784 DOI: 10.1016/j.joen.2024.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 02/29/2024] [Accepted: 03/18/2024] [Indexed: 04/20/2024]
Abstract
INTRODUCTION This systematic review aimed to compare reciprocating with continuous rotary instrumentation kinematics, by means of microcomputed tomography evaluations, in extracted human permanent teeth with moderate and severe canal curvatures. METHODS The research protocol was registered in the International Prospective Register of Systematic Reviews and given the reference number CRD42023404035. An electronic search was undertaken in MEDLINE (PubMed), EBSCO, Scopus, Web of Science databases until December 2021. Manual screening of issues in endodontic journals and references of relevant articles were assessed individually. The risk of bias (RoB) of the included articles was evaluated with the QUIN tool (Quality Assessment Tool for In Vitro Studies). RESULTS Among 1640 retrieved articles, 49 were included in the qualitative synthesis. Fifteen articles had low RoB, 33 articles had medium RoB, and only 1 study was at high RoB. Continuous rotary systems had better centering ability in both moderate and severe canal curvatures and resulted in less apical transportation in severely curved root canals. None of the kinematic systems was capable of instrumenting the entire canal surface area. Reciprocating kinematics systems tended to provide higher increase in surface area of severely curved canals and produced fewer dentinal microcracks in moderately curved canals. CONCLUSIONS The evidence presented in this review suggests that continuous rotary system seems to be better than reciprocating system in solving the major issues encountered during root canal instrumentation of extracted teeth with moderate and severe curvatures.
Collapse
Affiliation(s)
- Claudiu Călin
- Faculty of Dentistry, Department of Embryology, Carol Davila University of Medicine and Pharmacy, Bucharest, Romania
| | | | - Friedrich Paulsen
- Institute of Functional and Clinical Anatomy, Friedrich Alexander University Erlangen-Nürnberg, Erlangen, Germany
| | - Andreea C Didilescu
- Faculty of Dentistry, Department of Embryology, Carol Davila University of Medicine and Pharmacy, Bucharest, Romania.
| | - Tiberiu Niță
- Faculty of Dentistry, Department of Oral and Maxillofacial Surgery "Dan Theodorescu Hospital", Carol Davila University of Medicine and Pharmacy, Bucharest, Romania
| |
Collapse
|
4
|
Medina-Torres L, Cochran C, Bauer PA, Valcanaia AJ, Sindu D, Cavalcanti B, McDonald N. Effect of different instrumentation techniques on students' performance and outcomes of nonsurgical root canal treatment. J Dent Educ 2024; 88:940-948. [PMID: 38557969 DOI: 10.1002/jdd.13523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 01/18/2024] [Accepted: 03/03/2024] [Indexed: 04/04/2024]
Abstract
OBJECTIVES This study compared, retrospectively, the incidence of clinical errors and effects on treatment outcomes, when students were exposed to two different instrumentation techniques: a hybrid rotary technique (HYB), consisting of both hand instrumentation with hand stainless steel and Ni-Ti files plus the use of a rotary system (Vortex Blue, Dentsply Sirona), versus a full reciprocation instrumentation technique (WaveOne Gold [WOG], Dentsply Sirona). METHODS A total of 368 endodontic cases (n = 184) in anterior and premolar teeth, completed by dental students at the University of Michigan School of Dentistry from 2013 to 2022, were used for the study. The groups were evaluated by two calibrated clinicians, observing the incidence of clinical errors: file separations, over-instrumentation, ledges and transportations. Treatment outcomes were also observed. Data were analyzed statistically by Fisher's exact test and Mann-Whitney U test (p < 0.05). RESULTS No significant difference in file separations, ledges, and transportation was observed between the two groups. However, the WOG Group experienced significantly more over-instrumentation than HYB group, although this did not significantly affect tooth survival or periapical index (PAI). Cases with PAI scores of 5 were found to have significantly less tooth survival compared to the other PAI scores. CONCLUSIONS It can be concluded that both techniques in our study are well suited to advancing the endodontic dental education of students and novice operators, anticipating relatively successful outcomes of tooth survival, as long as the cases selected are less severe in progression preoperatively.
Collapse
Affiliation(s)
- Luis Medina-Torres
- Department of Cariology, Restorative Sciences and Endodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA
| | - Clarence Cochran
- Department of Cariology, Restorative Sciences and Endodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA
| | - Patricia Ann Bauer
- Department of Cariology, Restorative Sciences and Endodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA
| | - Andre Joao Valcanaia
- Department of Cariology, Restorative Sciences and Endodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA
| | - Devika Sindu
- Norton Thoracic Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
| | - Bruno Cavalcanti
- Department of Cariology, Restorative Sciences and Endodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA
| | - Neville McDonald
- Department of Cariology, Restorative Sciences and Endodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA
| |
Collapse
|
5
|
Srikumar GPV, Gadbail V, Alexander AK, Nishad G, Rahane S, Beautlin JS. An in vitro comparative evaluation of cyclic fatigue resistance of two rotary and two reciprocating file systems. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:774-779. [PMID: 39262602 PMCID: PMC11385906 DOI: 10.4103/jcde.jcde_2_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 02/11/2024] [Accepted: 06/10/2024] [Indexed: 09/13/2024]
Abstract
Context Root canal instrumentation is one of the important procedures for successful endodontic therapy. Unexpected fracture of files occurs during root canal instrumentation without any visible signs of deformation compromising the success of root canal treatment. Aims The aim of the study was to evaluate and compare cyclic fatigue resistance (CFR) of rotary and reciprocating files in simulated canals with 45°, 60°, and 90° angle of curvature. Settings and Design The study design was an In vitro study. Subjects and Methods Sixty nickel-titanium files, 30 each of rotary and reciprocating files were selected and divided into four groups (n = 15) of Neoendo Flex, ProTaper Next, WaveOne Gold (WOG), and Reciproc Blue (RPB) files. Each group was further subdivided into three subgroups containing five samples each based on their use in simulated canals with 45°, 60°, and 90° angle of curvature. To simulate root canals with 45°, 60°, and 90° angle of curvature, three artificial canals were designed in a stainless steel metal block. Each file was autoclaved, immersed in 3% sodium hypochlorite (NaOCl), and coated with 17% ethylenediaminetetraacetic acid (EDTA). Each file was tested for CFR using a torque-controlled reduction handpiece by instrumenting in a simulated canal for 10 s until fracture. The cycle of autoclaving, exposure to NaOCl, EDTA, and testing of CFR for 10 s per canal as per groups and subgroups was repeated again and again until the respective file fracture. The time taken to file fracture was recorded using a digital chronometer. The time taken for each file fracture (in minutes) was multiplied by the number of rotations per minute to attain the number of cycles to failure (NCF). Statistical Analysis Used The obtained results were subjected to statistical analysis using one-way analysis of variance and independent t-test. Results One-way ANOVA test showed a statistically significant difference between the four groups, P < 0.001. Independent "t"-test between individual subgroups showed a statistically significant difference, as P < 0.05. Conclusions WOG and RPB reciprocating file systems showed superior CFR, more especially in canals with abrupt 90° angle of curvature compared to both rotary file systems tested. Among rotary file systems tested, Neoendo Flex showed greater CFR than ProTaper Next.
Collapse
Affiliation(s)
- G P V Srikumar
- Department of Conservative Dentistry and Endodontics, Triveni Institute of Dental Sciences, Hospital and Research Centre, Bilaspur, Chhattisgarh, India
| | - Vaishnavi Gadbail
- Department of Conservative Dentistry and Endodontics, Triveni Institute of Dental Sciences, Hospital and Research Centre, Bilaspur, Chhattisgarh, India
| | - Arvind Kumar Alexander
- Department of Conservative Dentistry and Endodontics, Rajas Dental College and Hospital, Tirunelveli, Tamil Nadu, India
| | - Geeta Nishad
- Department of Conservative Dentistry and Endodontics, Triveni Institute of Dental Sciences, Hospital and Research Centre, Bilaspur, Chhattisgarh, India
| | - Shripriya Rahane
- Department of Conservative Dentistry and Endodontics, Rajesh Ramdasji Kambe Dental College and Hospital, Akola, Maharashtra, India
| | - J S Beautlin
- Department of Conservative Dentistry and Endodontics, Rajas Dental College and Hospital, Tirunelveli, Tamil Nadu, India
| |
Collapse
|
6
|
Schimdt TF, da Fonseca Roberti Garcia L, da Silveira Teixeira C, Alcalde MP, Hungaro Duarte MA, Bortoluzzi EA. How Does Intentional Apical Foraminal Enlargement Affect the Foramen and Root Canal Morphology? J Endod 2024; 50:651-658. [PMID: 38387796 DOI: 10.1016/j.joen.2024.02.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 02/11/2024] [Accepted: 02/12/2024] [Indexed: 02/24/2024]
Abstract
INTRODUCTION This study assessed the effect of intentional foraminal enlargement on the foramen and the apical root canal morphology. METHOD Sixty mesial roots of mandibular molars were scanned by micro-computed tomography. Their apical foramina were photographed with a stereomicroscope before and after preparation. Three groups were formed (n = 20) according to the working length (WL). G-1: foramen - 1 mm; G0: foramen; and G+1: foramen + 1 mm. Each group originated 2 subgroups (n = 10): G-1: Buchanan's patency (size 10 K-type file) and foraminal debridement (sizes 20, 25 and 30 K-type files); G0 and G+1: rotary foraminal enlargement (ProDesign S size 25/.08) or reciprocating foraminal enlargement (R25). The area, perimeter, transportation, and noninstrumented walls of the foramen were evaluated. The root canal transportation and the centering index of preparation at 1, 3 and 5 mm from the foramen were also assessed. Data were compared statistically (α = 5%). RESULTS The instruments used at the foramen and 1 mm beyond promoted foraminal enlargement and transportation. Regarding NIW, there was no difference between mechanized foraminal enlargements performed at the foramen or 1 mm beyond, similar to the manual foraminal debridement group (P > .05). There was no difference in transportation and centralization at 1-, 3-, and 5-mm apical levels, regardless of the instrumentation systems. CONCLUSION Mechanical preparation at the foramen, or 1 mm beyond, resulted in foraminal enlargement, transportation and were not able to touch all root canal walls that delimit the foramen.
Collapse
Affiliation(s)
- Tamer Ferreira Schimdt
- Endodontics Division, Department of Dentistry, Health Sciences Center, Federal University of Santa Catarina, Florianopolis, Santa Catarina, Brazil
| | - Lucas da Fonseca Roberti Garcia
- Endodontics Division, Department of Dentistry, Health Sciences Center, Federal University of Santa Catarina, Florianopolis, Santa Catarina, Brazil
| | - Cleonice da Silveira Teixeira
- Endodontics Division, Department of Dentistry, Health Sciences Center, Federal University of Santa Catarina, Florianopolis, Santa Catarina, Brazil
| | - Murilo Priori Alcalde
- Department of Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Marco Antonio Hungaro Duarte
- Department of Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Eduardo Antunes Bortoluzzi
- Endodontics Division, Department of Diagnosis & Oral Health, University of Louisville, Louisville, Kentucky.
| |
Collapse
|
7
|
Srivastava S. Root Canal Instrumentation: Current Trends and Future Perspectives. Cureus 2024; 16:e58045. [PMID: 38738101 PMCID: PMC11088362 DOI: 10.7759/cureus.58045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/11/2024] [Indexed: 05/14/2024] Open
Abstract
The evolution of root canal instrumentation techniques has significantly impacted the field of endodontics, enhancing both the efficiency and outcomes of treatments. This review outlines the transition from manual to mechanical and rotary instruments, highlighting the role of nickel-titanium (NiTi) alloys and smart technologies in advancing procedural precision and reducing patient discomfort. Key historical developments and technological innovations, such as digital imaging and navigation systems, are explored for their contributions to improved clinical outcomes and patient satisfaction. Additionally, the review addresses the challenges presented by the complex anatomy of the root canal system and the advent of current instrumentation techniques. The potential of emerging trends, including artificial intelligence and advances in materials science, is discussed in the context of future endodontic practices. Despite the progress, challenges related to using advanced instrumentation methods, ethical considerations, and the cost factor of new technologies persist. The present review underscores the ongoing need for research and development to further refine root canal instrumentation techniques, ensuring that advancements in endodontic care remain patient-centered and accessible.
Collapse
Affiliation(s)
- Swati Srivastava
- Department of Conservative Dental Sciences, College of Dentistry, Qassim University, Buraidah, SAU
| |
Collapse
|
8
|
Diaconu CT, Diaconu AE, Tuculina MJ, Mihai LL, Gheorghiță M, Gheorghiță LM, Mărășescu P, Gliga A, Diaconu OA. Assessment of the Cyclic Fatigue Performance of the Novel Protaper Ultimate File System Used in Different Kinematics: An In Vitro Study. J Funct Biomater 2024; 15:85. [PMID: 38667542 PMCID: PMC11051539 DOI: 10.3390/jfb15040085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 03/06/2024] [Accepted: 03/27/2024] [Indexed: 04/28/2024] Open
Abstract
This in vitro study aims to assess the cyclic fatigue resistance of the Protaper Ultimate (PTU) files compared to the Protaper Gold (PTG) and the M3 UDG (M3) files using various motion kinematics in simulated canals. As far as the authors are aware, no study has previously compared the three file systems before this current investigation. Therefore, closing this information gap is the goal of the current research. Methods: A total of (60 new endodontic files were randomly divided into 6 groups (10 files per group); groups 1, 3, and 5 used continuous rotation (CR), while groups 2, 4, and 6 used forward reciprocating motion (FRM). A manufactured stainless-steel artificial canal was used to perform the cyclic fatigue testing. The results were analyzed using Student's t-test and two-way ANOVA. All pairwise comparisons revealed statistically significant differences in the time to failure (TTF) for every study group (p < 0.001), with the exception of the PTG and M3 files, which performed similarly using both CR and FRM. Conclusions: The PTU files performed better than the PTG and M3 files in terms of the TTF and number of cycles to failure (NCF) using both CR and FRM.
Collapse
Affiliation(s)
- Cezar Tiberiu Diaconu
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| | - Anca Elena Diaconu
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| | - Mihaela Jana Tuculina
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| | - Laurența Lelia Mihai
- Faculty of Dental Medicine, University Titu Maiorescu of Bucharest, 031593 Bucharest, Romania
| | - Mircea Gheorghiță
- Faculty of Dental Medicine, Department of Oral and Maxillofacial Surgery, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Lelia Mihaela Gheorghiță
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| | - Petre Mărășescu
- Faculty of Dental Medicine, Department of Dental Prothesis Technology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Alexandru Gliga
- Faculty of Dental Medicine, Department of Operative Dentistry, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania;
| | - Oana Andreea Diaconu
- Faculty of Dental Medicine, Department of Endodontics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.D.); (A.E.D.); (L.M.G.); (O.A.D.)
| |
Collapse
|
9
|
Abdel-Baset ST, Fahmy SH, Obeid MF. Can instrumentation kinematics affect postoperative pain and substance P levels? A randomized controlled trial. BMC Oral Health 2024; 24:102. [PMID: 38233887 PMCID: PMC10792914 DOI: 10.1186/s12903-024-03882-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 01/10/2024] [Indexed: 01/19/2024] Open
Abstract
BACKGROUND This study aimed to assess the influence of continuous rotation and reciprocation kinematics on postoperative pain (POP) levels and substance P (SP) levels in patients diagnosed with irreversible pulpitis and symptomatic apical periodontitis (SAP). MATERIALS AND SUBJECTS A total of twenty patients were randomly assigned into two groups: Continuous Rotation Group (CRG) (n = 10), subjected to mechanical preparation with the EdgeEndox7 rotary system (Albuquerque, NM, USA), and Reciprocation Group (RG) (n = 10), treated with the EdgeOne Fire reciprocating system (Albuquerque, NM, USA). Apical fluid (AF) samples were collected, and SP levels were quantified through radioimmunoassay. POP was assessed using the Numerical Rating Scale (NRS) at various time intervals (preoperatively, 6 h, 12 h, 24 h, 48 h, and 72 h). Data were statistically analyzed utilizing the independent t-test, Mann-Whitney U test, Friedman's test, and Nemenyi post hoc test. RESULTS There was a significant increase in SP levels in the reciprocating group compared to the continuous rotation group (P ≤ 0.05). Additionally, patients in the reciprocating group reported significantly higher POP levels (P ≤ 0.05) at all measured intervals (6 h, 12 h, 24 h, and 48 h), with both groups exhibiting similar pain level reductions at the 72-hour mark. CONCLUSION Our findings suggest that continuous rotation kinematics in root canal preparation leads to a considerable reduction in SP expression and POP. TRIAL REGISTRATION The study protocol was retrospectively registered on the www. CLINICALTRIALS gov database (NCT06081335) at (13/10/2023) after the approval of the Ethics Committee, Faculty of Dentistry, Ain Shams University (FDASU-RecIM012135).
Collapse
Affiliation(s)
| | - Sarah Hossam Fahmy
- Department of Endodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Maram Farouk Obeid
- Department of Endodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
| |
Collapse
|
10
|
Ahmed HMA, El-Karim I, Duncan HF, Krastl G, Galler K. Implications of root, pulp chamber, and canal anatomy on pulpotomy and revitalization procedures. Clin Oral Investig 2023; 27:6357-6369. [PMID: 37870593 DOI: 10.1007/s00784-023-05284-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Accepted: 09/26/2023] [Indexed: 10/24/2023]
Abstract
OBJECTIVES This review aims to discuss the implications of anatomy of the root, pulp chamber, and canals on pulpotomy and revitalization procedures (RPs) as treatment alternatives to root canal treatment procedures. METHODS This narrative review was undertaken to address two main questions - why remove vital pulp tissue in teeth with complex canal anatomy when it can be preserved? And why replace the necrotic pulp in teeth with mature roots with a synthetic material when we can revitalize? This review also aims to discuss anatomical challenges with pulpotomy and revitalization procedures. RESULTS Maintaining the vitality of the pulp via partial or full pulpotomy procedures avoids the multiple potential challenges faced by clinicians during root canal treatment. However, carrying out pulpotomy procedures requires a meticulous understanding of the pulp chamber anatomy, which varies from tooth to tooth. Literature shows an increased interest in the application of RPs in teeth with mature roots; however, to date, the relation between the complexity of the root canal system and outcomes of RPs in necrotic multi-rooted teeth with mature roots is unclear and requires further robust comparative research and long-term follow-up. CONCLUSIONS Whenever indicated, pulpotomy procedures are viable treatment options for vital teeth with mature roots; however, comparative, adequately powered studies with long-term follow-up are needed as a priority in this area. RPs show promising outcomes for necrotic teeth with mature roots that warrant more evidence in different tooth types with long-term follow-ups. CLINICAL RELEVANCE: Clinicians should be aware of the pulp chamber anatomy, which is subject to morphological changes by age or as a defensive mechanism against microbial irritation, before practicing partial and full pulpotomy procedures. RP is a promising treatment option for teeth with immature roots, but more evidence is needed for its applications in teeth with mature roots. A universal consensus and considerably more robust evidence are needed for the standardization of RPs in teeth with mature roots.
Collapse
Affiliation(s)
- Hany Mohamed Aly Ahmed
- Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
| | - Ikhlas El-Karim
- School of Medicine, Dentistry and Biomedical Sciences, Queen's University, Belfast, UK
| | - Henry F Duncan
- Division of Restorative Dentistry and Periodontology, Dublin Dental University Hospital, Trinity College Dublin, Dublin, Ireland
| | - Gabriel Krastl
- Department of Conservative Dentistry and Periodontology, Center of Dental, Traumatology University Hospital of Würzburg Pleicherwall, 2, 97070, Würzburg, Germany
| | - Kerstin Galler
- Department of Restorative Dentistry and Periodontology, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
11
|
Chan CW, Romeo VR, Lee A, Zhang C, Neelakantan P, Pedullà E. Accumulated Hard Tissue Debris and Root Canal Shaping Profiles Following Instrumentation with Gentlefile, One Curve, and Reciproc Blue. J Endod 2023; 49:1344-1351. [PMID: 37516238 DOI: 10.1016/j.joen.2023.07.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 07/19/2023] [Accepted: 07/20/2023] [Indexed: 07/31/2023]
Abstract
INTRODUCTION This laboratory study aimed to evaluate the accumulated hard tissue debris (AHTD) and shaping performance following root canal instrumentation with a novel stainless steel rotary system (Gentlefile; MedicNRG, Kibbutz Afikim, Israel) compared with two single-file nickel-titanium instruments of different kinematics through micro-computed tomography (micro-CT) analysis. METHODS Thirty isthmus-containing mesial roots of human mandibular molars with a curvature of 15°-35° were scanned with micro-CT at an isotropic resolution of 12 μm and randomly assigned to three groups (n = 10) according to the instruments used for canal preparation: Gentlefile (GF; #23/.04), One Curve (OC; #25/.06; Micro-Mega, Besancon, France), and Reciproc Blue R25 (RB; #25/.08; VDW, Munich, Germany). The AHTD, unprepared canal surface area, volume changes, surface area changes, and transportation were evaluated by comparing preoperative and postoperative micro-CT images. In addition, the time required for canal preparation was recorded. Data were statistically analyzed using the one-way analysis of variance (ANOVA) test or the Kruskal-Wallis test at a significance level of 5%. RESULTS No significant differences were observed in the percentage of AHTD or in the unprepared canal surface area between the three groups (P > .05). The RB group demonstrated a significantly greater percentage increase in volume and surface area than the GF group (P < .05). The GF and OC groups showed significantly less transportation at 3 mm from the apex than the RB group (P < .001). The OC group required significantly less time for instrumentation than the RB and GF groups (P < .05). CONCLUSIONS Instrumentation with GF (#23/.04), OC, and RB yielded similar levels of AHTD and unprepared surface area in isthmus-containing curved canals. GF achieved this with less dentin removal and apical transportation, at the expense of a longer preparation time.
Collapse
Affiliation(s)
- Chi Wai Chan
- Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Virginia Rosy Romeo
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Angeline Lee
- Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Chengfei Zhang
- Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China.
| | - Prasanna Neelakantan
- Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China; Department of Endodontics, Arthur A. Dugoni School of Dentistry, University of the Pacific, San Francisco, CA.
| | - Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| |
Collapse
|
12
|
Grande NM, Castagnola R, Minciacchi I, Marigo L, Plotino G. A review of the latest developments in rotary NiTi technology and root canal preparation. Aust Dent J 2023; 68 Suppl 1:S24-S38. [PMID: 37960998 DOI: 10.1111/adj.12998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2023] [Indexed: 11/15/2023]
Abstract
The introduction of nickel-titanium (NiTi) mechanical instruments dramatically changed clinical endodontics over the last few decades. Before NiTi, it was necessary to use more instruments to create an ideal root canal shape, and many approaches, sequences and techniques were developed over the years. Recently, NiTi endodontic instruments have undergone a series of changes brought about by modifications in design, surface treatments, and thermal treatments to improve their root canal preparation outcomes and reduce associated canal preparation risks during root canal treatment. Heat treatment is one of the most fundamental approaches to improving the fatigue resistance and flexibility of NiTi endodontic instruments. In addition, new kinematics have been developed to offer greater safety and efficiency. This narrative review describes the general properties and manufacturing of NiTi instruments, and the mechanical system evolution of NiTi instruments.
Collapse
Affiliation(s)
- N M Grande
- Dipartimento di Testa-Collo e organi di senso, Università Cattolica del Sacro Cuore, Rome, Italy
| | - R Castagnola
- Dipartimento di Testa-Collo e organi di senso, Università Cattolica del Sacro Cuore, Rome, Italy
| | | | - L Marigo
- Dipartimento di Testa-Collo e organi di senso, Università Cattolica del Sacro Cuore, Rome, Italy
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo. Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | | |
Collapse
|
13
|
Marques RPS, Oliveira NM, Barbosa VRP, Bresolin CR, Mello-Moura ACV, Lara JS, Novaes TF, Mendes FM. Reciprocating instrumentation for endodontic treatment of primary molars: 24-month randomized clinical trial. Int J Paediatr Dent 2022. [PMID: 36522131 DOI: 10.1111/ipd.13042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 10/27/2022] [Accepted: 11/17/2022] [Indexed: 12/23/2022]
Abstract
BACKGROUND Although reciprocating instrumentation has been extensively studied for permanent teeth, stronger evidence for its use in primary teeth is lacking. AIM The aim of this randomized clinical trial was to compare the efficacy of endodontic treatment in primary molars using reciprocating (RECIP) and manual (MAN) instrumentation techniques after 24 months. DESIGN Primary molars with indication of endodontic treatment were randomly divided into two groups: MAN and RECIP. Treatments were performed, and root canals were filled with calcium hydroxide and iodoform paste. Teeth were later restored with bulk-fill composite resin and re-evaluated after 6, 12, 18, and 24 months. The primary outcome was the success of the endodontic treatment evaluated by Cox regression analysis adjusted by cluster and success rate after 24 months in the intention-to-treat (ITT) population. Instrumentation time, discomfort, postoperative pain, and quality of root canal filling were also evaluated as secondary endpoints. RESULTS A total of 151 primary win 107 children were included, and 137 were followed up for 24 months. Success rate of teeth allocated to the MAN group was 57.3% and 55.3% for RECIP (p = .792); MAN instrumentation, however, was more time-consuming (p = .005). CONCLUSION The efficacy of endodontic treatment in primary molars using reciprocating and manual instrumentation is similar after 24 months.
Collapse
Affiliation(s)
| | - Natalia Matsuda Oliveira
- Department of Pediatric Dentistry, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | | | | | - Anna Carolina Volpi Mello-Moura
- Faculty Dental Medicine, Center for Interdisciplinary Research in Health - SalivaTec Lab, Universidade Catolica Portuguesa, Viseu, Portugal
| | - Juan Sebastian Lara
- Department of Cariology, Operative Dentistry and Dental Public Health, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | | | - Fausto Medeiros Mendes
- Department of Pediatric Dentistry, School of Dentistry, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
14
|
Braambati D, Monteiro RDC, Coelho MS, Soares ADJ, Frozoni M. Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values. Braz Dent J 2022; 33:28-35. [PMID: 36477962 PMCID: PMC9733375 DOI: 10.1590/0103-6440202204855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 10/11/2022] [Indexed: 12/12/2022] Open
Abstract
This study assessed 3 endodontic motors, X-Smart Plus (Dentsply Sirona, Ballaigues, Switzerland), VDW.Silver Reciproc (VDW GmbH, München, Germany) and, iRoot (Bassi Endodontics, Belo Horizonte, Brazil) in 2 different reciprocating settings. The movements evaluated were 170° in counter-clockwise (CCW) and 50° in clockwise (CW) at 350 RPM, and 150° CCW and 30° CW at 300 RPM. For the X-Smart Plus and VDW Silver the settings used were the ones in the motor library. For the iRoot, the motor was adjusted to the angles of the study. A customized optic target was attached to the contra-angle of the motor and the movements were recorded with a high-resolution camera (K2 DistaMaxTM Long-Distance Microscope System, Infinity Photo-Optical Company, Colorado, EUA) at 2,400 frames per second (FPS). The images were analyzed with the Vision Research software (Inc. Headquarters, Wayne, New Jersey, EUA). The following kinematic parameters were assessed: CCW angle, CW angle, speed (RPM) at both directions, and, standstill time at each change of directions. The Intraclass Correlation Coefficient (ICC) and Kruskal-Wallis (method of Dunn) were used at a significant level of 5%. There was no statistically significant difference among the motors at the 150°/30° setting (P > .05); the iRoot was the least reliable at the 170°/50° setting for CCW angle, speed, and net angle parameters (P < 0.05). The standstill time of all motors in both directions was identical. None of the motors were able to reproduce faithfully the set movements. The iRoot motor presented a higher discrepancy when compared to X-Smart and VDW Silver.
Collapse
Affiliation(s)
- Dieimes Braambati
- Endodontic Department, São Leopoldo Mandic School of Dentistry, Campinas- SP, Brazil
| | | | - Marcelo Santos Coelho
- Endodontic Department, São Leopoldo Mandic School of Dentistry, Campinas- SP, Brazil
| | | | - Marcos Frozoni
- Endodontic Department, São Leopoldo Mandic School of Dentistry, Campinas- SP, Brazil
| |
Collapse
|
15
|
Wear Analysis of Four Different Single-File Reciprocating Instruments before and after Four Uses in Simulated Root Canals. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12126253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The aim of this study is to assess the surface alterations of four reciprocating instruments before and after the shaping of four resin-simulated root canals. The following four different reciprocating instruments are selected: 10 Reciproc Blue (RB25), 10 WaveOne Gold (WOG), 10 EdgeOne Fire (EOF) and 10 recently introduced instruments OneRECI (OR), for a total of 40 new instruments. Before root canal shaping, each instrument is mounted on a stub in a standardized position and observed using a scanning electron microscope (SEM) to detect any surface alteration, such as microfractures, metal defects, deformations, blunt and disruption of cutting edges, debris, pitting and tip flattening. Micrographs are acquired at the level of the tip, 4 mm, 8 mm and 12 mm from it. After that, each instrument is used in four simulated resin root canals. SEM observation was repeated after the simulated clinical use to assess the wear resistance of the instruments. Surface alterations are registered before and after instrumentation and statistical analysis is performed using a Chi-Square test to verify homogeneity of defects distribution and GLM to evaluate the differences of RMS at baseline and after use for both groups (α level 0.05). Before simulated clinical uses, no alterations are found except for three cases of EOF with metal strips in correspondence to the tip, disruption of the cutting edge of WOG and oily spotting on two different OR. After simulated clinical use, EOF shows a statistically significant difference in terms of spiral distortion and flattening of the cutting edges. The OR shows the highest presence of debris despite the ultrasonic cleaning procedures. No instrument fractures are observed. EOF should be discarded after four clinical uses and carefully inspected after each insertion into root canals. Moreover, tough attention should be paid during disinfection and cleaning procedures after instrumentation considering the copious debris detected in each instrument, particularly in OR.
Collapse
|
16
|
Altufayli MD, Salim B, Katbeh I, Merei R, Mamasaidova Z. Shaping Ability of Reciproc Blue Versus One Curve in Curved Canal: An In-Vitro Study. Cureus 2022; 14:e24387. [PMID: 35619838 PMCID: PMC9126444 DOI: 10.7759/cureus.24387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/22/2022] [Indexed: 11/25/2022] Open
Abstract
The introduction of nickel-titanium (NiTi) rotary instruments improved the root canal preparation of the narrow and curved root canals, especially after the introduction of thermomechanical treated (NiTi) alloys that have a high flexibility to prepare the curved canal reducing the common clinical complication, such as fracture, the change of the original shape of the root canal as a result of the change in the curvature of the curved root canal, the change of the working length which caused by the creation of the ledges, canal transporting and zipping especially in medium and highly curved canal. This study aimed to compare the shaping ability of two heat-treated nickel-titanium single file systems using reciprocation motion and rotary motion in curved canals. Materials and methods Thirty extracted human teeth with one curved root at 25 to 56 degrees were used, two NiTi single file systems were used to prepare the curved root canal in two groups: Reciproc R25 (Munich, Germany: VDW) group (n=15) and One Curve (Besancon, France: Micro-Mega) group (n=15). Curved root canal instrumentation outcomes were evaluated using cone-beam computed tomography (CBCT). Kruskal-Wallis with Bonferroni post hoc test was used to assess differences between working length, the angle and radius of curvature after instrumentation. Results There was a significant difference in angle and radius of curvature (-1.83° One Curve, -2.25° Reciproc blue and -0.18 mm One Curve, -0.19 mm Reciproc blue, respectively) (p<0.05) after instrumentation for both One Curve and Reciproc blue groups, and there was no significant difference in working length change (-0.16 mm One Curve, -0.32 mm Reciproc blue) after instrumentation of both One Curve and Reciproc blue groups (p>0.05). Conclusion The Reciproc blue single file system with reciprocation movement and One Curve with continuous movement cause a significant difference in curvature and radius of curved root canal affecting the original shape of the root canal with no significant difference in working length of the curved root canal.
Collapse
|
17
|
Chinchiyanont P, Yanpiset K, Banomyong D, Thongbai-On N. Shaping ability of non-adaptive and adaptive core nickel-titanium single-file systems with supplementary file in ribbon-shaped canals analysed by micro-computed tomography. AUST ENDOD J 2022; 49:38-47. [PMID: 35255157 DOI: 10.1111/aej.12609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 01/17/2022] [Accepted: 02/02/2022] [Indexed: 11/28/2022]
Abstract
This study compared shaping ability between two single-file systems and before/after using supplementary file in untouched area, volume of removed dentin, maximum cut depth (the highest cut depth by main file) and remaining thinnest dentin (the thinnest root dentin after preparation). Ribbon-shaped distal canals of mandibular molars were prepared with non-adaptive core (WaveOne Gold) or adaptive core (XP-endo Shaper) files (n = 15/group) and additionally prepared with a supplementary file (XP-endo Finisher), and the shaping ability was investigated using micro-computed tomography. XP-endo Shaper group demonstrated significantly less overall untouched area than WaveOne Gold group (38.21 ± 6.98% vs. 47.68 ± 9.16%) (p < 0.05). No significant difference was detected between XP-endo Shaper and WaveOne Gold groups in volume of removed dentin (1.85 ± 0.53 vs. 1.66 ± 0.33 mm3 ), maximum cut depth (0.10-0.28 vs. 0.10-0.29 mm) and remaining thinnest dentin (0.66-0.80 vs. 0.78-0.88 mm). Supplementary XP-endo Finisher treatment significantly decreased untouched area (11%-23% reduction) (p < 0.05) with minimally cut root dentin (0.01-0.02 mm).
Collapse
Affiliation(s)
- Parichat Chinchiyanont
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Kallaya Yanpiset
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Danuchit Banomyong
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | | |
Collapse
|
18
|
Chaniotis A, Ordinola Zapata R. Present status and future directions -Management of curved and calcified root canals. Int Endod J 2022; 55 Suppl 3:656-684. [PMID: 35106792 DOI: 10.1111/iej.13685] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 01/14/2022] [Accepted: 01/18/2022] [Indexed: 12/01/2022]
Abstract
Root canal curvature and calcification introduce factors that increase the risk of procedural accidents during root canal treatment. The inability to achieve patency to the apical third, asymmetrical dentine removal leading to transportation, perforation and instrument fracture inside the curved trajectories are some of the procedural problems that might jeopardize the management of intraradicular infection and result in poor treatment outcomes. In fact, curved and constricted canals introduce such complexity that total instrumentation concepts and specially designed instruments have been developed to deal with the challenge. This narrative review seeks to provide and consolidate the principles necessary for understanding the dynamics of curved and constricted canal management and to improve the understanding for future developments in this field.
Collapse
Affiliation(s)
- Antonis Chaniotis
- Private practice, National and Kapodistrian University of Athens, Dental School, Athens, Greece
| | - Ronald Ordinola Zapata
- Division of Endodontics, School of Dentistry, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
19
|
Saber SM, Alfadag AMA, Nawar NN, Plotino G, Hassanien EES. Instrumentation Kinematics Does Not Affect Bacterial Reduction, Post-Operative Pain and flare-ups: A Randomized Clinical Trial. Int Endod J 2022; 55:405-415. [PMID: 35100456 DOI: 10.1111/iej.13695] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 01/26/2022] [Accepted: 01/27/2022] [Indexed: 11/25/2022]
Abstract
AIM This randomized clinical trial aimed to assess the effect of instrumentation kinematics (reciprocation or continuous rotation) on bacterial reduction, post-operative pain and incidence of flare-ups after root canal treatment of single-rooted mandibular premolars with asymptomatic apical periodontitis. METHODOLOGY Sixty-six patients were included in this prospective, parallel, randomized clinical trial. Patients were randomly allocated into two groups (N=33) according to the kinematics of the shaping instrument: WaveOne Gold (WO) used in reciprocation or One Shape (OS) used in continuous rotation. Under complete asepsis, bacterial samples were taken before (S1) and after (S2) a standard cleaning and shaping protocol. Evaluation of bacterial reduction was done by both culture technique and quantitative real-time polymerase chain reaction (qPCR) analysis. Post-operative pain was evaluated using the visual analog scale (VAS) after 24, 48- and 72-hours following treatment, while flare-ups were recorded as a binary outcome (Yes/No). Independent and paired t-tests were used for inter and intragroup comparisons for bacterial count data respectively. For post-operative pain score, intergroup comparisons were analyzed using Mann-Whitney U test while intragroup comparisons were analyzed using Friedman test followed by pairwise comparisons utilizing Wilcoxon signed rank test with Bonferroni correction. The significance level was set at p≤0.05 within all tests. RESULTS All the allocated participants received the intervention and were analyzed. The comparison between culture and qPCR methods showed that qPCR analysis demonstrated significantly higher pre-instrumentation baseline bacterial count (p<0.05). The percentage of bacterial reduction, detected by either method, significantly decreased after instrumentation using either rotation or reciprocation kinematics (p<0.05). However, the difference between the WOG or OS files was statistically non-significant (p>0.05). The intra-group comparisons showed a significant reduction in post-operative pain with time (p<0.05) for both groups. However, the inter-group comparison demonstrated that the difference in post-operative pain after the use of either WOG or OS was statistically non-significant (p>0.05). The incidence of flare-ups between both groups was also not-significant (p=1). CONCLUSIONS Shaping kinematics, either rotation or reciprocation motions, had no impact on bacterial reduction and the incidence of post-operative pain and flare-ups after root canal preparation of single-rooted premolars with asymptomatic apical periodontitis.
Collapse
Affiliation(s)
- Shehabeldin Mohamed Saber
- Department of Endodontics, Ain Shams University, Cairo, Egypt.,Department of Endodontics, The British University, El-Shorouk city, Egypt
| | | | - Nawar Naguib Nawar
- Department of Endodontics, The British University, El-Shorouk city, Egypt
| | | | - Ehab El-Sayed Hassanien
- Department of Endodontics, Ain Shams University, Cairo, Egypt.,El-Galala University, El-Galala city, Egypt
| |
Collapse
|
20
|
Das D, Barai S, Kumar R, Bhattacharyya S, Maity A, Shankarappa P. Comparative evaluation of incidence of dentinal defects after root canal preparation using hand, rotary, and reciprocating files: An ex vivo study. J Int Oral Health 2022. [DOI: 10.4103/jioh.jioh_136_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
21
|
|
22
|
Bhat R, Kini A, Shetty P, Kansara P, Penugonda B. Cyclic Fatigue Resistance and Surface Roughness of Rotary NiTi Instruments after Simulated Clinical Use in Curved Root Canals – An Atomic Force Microscopy Study. PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLÍNICA INTEGRADA 2022. [DOI: 10.1590/pboci.2022.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Affiliation(s)
| | - Arjun Kini
- New York University College of Dentistry, USA
| | | | | | | |
Collapse
|
23
|
Macedo LMDD, Silva-Sousa YTC, Olivato Junior O, Baltazar AF, Rached-Junior FJA. Different biomechanical preparation protocols on the penetration and bond strength of the filling material to dentin. Braz Dent J 2021; 32:12-22. [PMID: 34877974 DOI: 10.1590/0103-6440202104472] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Accepted: 10/13/2021] [Indexed: 11/21/2022] Open
Abstract
The aim of this study was to evaluate the influence of different instruments and mechanisms of agitation of the irrigating solution on the penetration by confocal laser scanning microscopy (CLSM), and the bond strength (BS) of the filling material to the dentin by push-out test. Human premolars were distributed in two experimental groups (n=30), according to the instrumentation system: ProTaper Next (PN) or XP-endo Shaper (XS) and three irrigation protocol (n=10): NaviTip (Nv), XP-endo Finisher (XF), passive ultrasonic irrigation/ XP-endo Finisher (PUIXF). The 2.5% NaOCl and 17% EDTA were the irrigating solutions used. The filling was performed using a lateral condensation technique, with AH Plus added to 0.1% rodhamine B. The roots were sectioned, obtaining 2 slices for each third of the root. The first slice was submitted to the sealer penetration analysis and the push-out test. The second slice was submitted to qualitative analysis (SEM) of the union interface. For the penetration (%) Tukey showed that PNXF (82.38±13.48), PNPUIXF (82.48± 12.02), XSXF (82.24±11.28) and XSPUIXP (86.23±10.45) presented the highest values, different (p<0.05) from PNNv (68.29±15.12) and XSNv (71.41±16.50). The BS (MPa) test evidenced that in the cervical third, PNPF (4.92±1.04) and XPSPF (5.03±0.70) obtained the highest values differing from the others groups (p<0.05). CSLM and SEM showed greater penetration of the sealer on the entire length of the root canal when the irrigation solution was stirred. In conclusion that the association PUI and XP-endo Finisher favored the penetration and bond strength of the filling material to the root dentin.
Collapse
|
24
|
Machado R, Vigarani G, Macoppi T, Pawar A, Glaci Reinke SM, Kovalik Gonçalves AC. Extrusion of debris with and without intentional foraminal enlargement - A systematic review and meta-analysis. AUST ENDOD J 2021; 47:741-748. [PMID: 34146366 DOI: 10.1111/aej.12539] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 05/23/2021] [Accepted: 05/26/2021] [Indexed: 01/22/2023]
Abstract
This systematic review and meta-analysis was sought to assess whether intentional foraminal enlargement (IFE) is responsible for extrusion of a larger quantity of debris from extracted human teeth with fully formed apexes. Following the recommendations of Preferred Reporting Items for Systematic Review and Meta-Analysis - PRISMA, electronic and manual searches were performed to identify studies that evaluated the extrusion of debris, comparing different apical limits of instrumentation (with/without IFE). The quality of the studies selected was evaluated, and statistical analysis was conducted. To perform the meta-analysis, just 3 papers could be used. The heterogeneity was high, however; there was no statistically significant difference in relation to the extrusion of debris in teeth either submitted or not submitted to IFE. The general risk of bias was moderate. In conclusion, IFE is not responsible for extrusion of a larger quantity of debris from extracted human teeth with fully formed apexes.
Collapse
Affiliation(s)
- Ricardo Machado
- Department of Endodontics, School of Dentistry, Regional University of Blumenau, Blumenau, Santa Catarina, Brazil
| | - Gislayne Vigarani
- Student of Dentistry, Regional University of Blumenau, Blumenau, Santa Catarina, Brazil
| | - Tainara Macoppi
- Student of Dentistry, Regional University of Blumenau, Blumenau, Santa Catarina, Brazil
| | - Ajinkya Pawar
- Department of Conservative Dentistry and Endodontics, Nair Hospital Dental College, Mumbai, Maharashtra, India
| | - Stella Maria Glaci Reinke
- Department of Endodontics, School of Dentistry, Regional University of Blumenau, Blumenau, Santa Catarina, Brazil
| | | |
Collapse
|
25
|
Chi D, Zhang Y, Lin X, Tong Z. Cyclic fatigue resistance for six types of nickel titanium instruments at artificial canals with different angles and radii of curvature. Dent Mater J 2021; 40:1129-1135. [PMID: 34121024 DOI: 10.4012/dmj.2020-358] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study evaluated the cyclic fatigue resistance for six types of 25# NiTi instruments. A traditional manufacturing instrument, an M wire instrument, a gold treatment instrument, a controlled memory (CM) wire instrument, a CM wire instrument with electrical discharge machining (EDM), and an R-phase heat treatment instrument, were operated in the different curved artificial canals. The fracture time (FT) and number of cycles to fracture (NCF) of the NiTi instruments were higher at 45° angles and double-curvature canals than at 60° angles. Except for the instruments with gold technology and EDM technology, others showed the longest FT and the highest NCF at an 8 mm radius of curvature. Morphological characteristics of cyclic fatigue were exhibited on the cross-section and lateral view of fracture fragments. The use of M-wire, R-phase wire, CM-wire, gold technology, EDM technology, and reciprocating movement were beneficial to enhance the cyclic fatigue resistance of NiTi files.
Collapse
Affiliation(s)
- Danlu Chi
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University
| | - Yuejiao Zhang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University
| | - Xinwei Lin
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University
| | - Zhongchun Tong
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University.,Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University
| |
Collapse
|
26
|
Campos DS, Rodrigues EA, Bueno CEDS, Fontana CE, da Silva EJNL, de Lima CO, De Martin AS. The ability of reciprocating glide path instruments to reach the full root canal working length. AUST ENDOD J 2021; 47:487-492. [PMID: 33754413 DOI: 10.1111/aej.12510] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/07/2021] [Indexed: 11/30/2022]
Abstract
This study evaluated the ability of reciprocating glide path instruments to reach the full working length (RFWL). Thirty mesial roots of mandibular molars were matched into 2 groups (n = 15 teeth, 30 root canals), according to the system used for glide path: WaveOne Gold Glider (WOGG) and R-Pilot. The samples with fractured instruments or when it was not possible to RFWL were scanned using micro-computed tomography. Fractured instruments were also visualised through a scanning electron microscopy to verify the type of fracture. The parameters were compared statistically by Fisher's and chi-square tests (P < 0.05). No instrument fractures were observed in the R-pilot, while 2 fractures occurred in the WOGG group (P > 0.05). RFLW was achieved in 29 canals (96.66%) and 28 canals (93.33%) with R-pilot and WOGG instruments, respectively (P > 0.05). The instruments are able to RFWL in mesial canals of mandibular molars. WOGG showed two fractures while no R-Pilot instruments fractured.
Collapse
Affiliation(s)
- Daniel Souza Campos
- Department of Endodontics, School of Dentistry, São Leopoldo Mandic Faculty, Campinas, Brazil
| | - Evaldo Almeida Rodrigues
- Department of Endodontics, School of Dentistry, State University of Feira de Santana (UEFS), Feira de Santana, Brazil
| | | | - Carlos Eduardo Fontana
- Department of Endodontics, School of Dentistry, São Leopoldo Mandic Faculty, Campinas, Brazil
| | - Emmanuel João Nogueira Leal da Silva
- Department of Endodontics, School of Dentistry, State University of Rio de Janeiro (UERJ), Rio de Janeiro, Brazil.,Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - Carolina Oliveira de Lima
- Department of Endodontics, School of Dentistry, State University of Rio de Janeiro (UERJ), Rio de Janeiro, Brazil
| | | |
Collapse
|
27
|
Predin Djuric N, Van Der Vyver P, Vorster M, Vally ZI. Comparison of apical debris extrusion using clockwise and counter-clockwise single-file reciprocation of rotary and reciprocating systems. AUST ENDOD J 2021; 47:394-400. [PMID: 33638593 DOI: 10.1111/aej.12490] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 01/14/2021] [Accepted: 01/29/2021] [Indexed: 11/28/2022]
Abstract
The aim was to evaluate apical debris extrusion produced by a single-file system used in counter-clockwise reciprocation and compare it to rotary single-file systems used in clockwise rotation and clockwise reciprocation. A total of 100 first mandibular molars were divided into five groups (n = 20): (i) WaveOne Gold Glider and Primary instrument in counter-clockwise reciprocation; (ii) One G and One Curve file in clockwise rotation; (iii) One G and One Curve file in clockwise reciprocation; (iv) TruNatomy Glider and Prime instrument in clockwise rotation; and (v) TruNatomy Glider and Prime instrument in clockwise reciprocation. Apical debris extruded was measured after glide path preparation and canal preparation. WaveOne Gold displayed significantly higher amounts of apical debris extrusion in all the groups (P < 0.05). The lowest mean values were recorded by clockwise reciprocation groups: TruNatomy Glider, One Curve and TruNatomy Glider and Prime combined value, for glide path, canal preparation and combined mean values, respectively.
Collapse
Affiliation(s)
- Natasa Predin Djuric
- Department of Odontology, Faculty of Health Sciences, School of Dentistry, Oral and Dental Hospital, University of Pretoria, Pretoria, Gauteng, South Africa
| | - Peet Van Der Vyver
- Department of Odontology, Faculty of Health Sciences, School of Dentistry, Oral and Dental Hospital, University of Pretoria, Pretoria, Gauteng, South Africa
| | - Martin Vorster
- Department of Odontology, Faculty of Health Sciences, School of Dentistry, Oral and Dental Hospital, University of Pretoria, Pretoria, Gauteng, South Africa
| | - Zunaid Ismail Vally
- Department of Odontology, Faculty of Health Sciences, School of Dentistry, Oral and Dental Hospital, University of Pretoria, Pretoria, Gauteng, South Africa
| |
Collapse
|
28
|
Nasrabadi N, Jamali S, Vojoodi MG, Jamali M. The impact of Distinctive Root Canal Instrumentation Systems on Endotoxin Lessening from the Root Canal: A Systematic Review and Meta-Analysis. PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLÍNICA INTEGRADA 2021. [DOI: 10.1590/pboci.2021.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
29
|
de Camargo EJ, Duarte MAH, Alcalde MP, Só MVDR, Vasconcelos BCD, Silva EJNL, Plotino G, Vivan RR. Safety of large preparation with different instruments in the buccal canals of maxillary molars. AUST ENDOD J 2020; 47:81-89. [PMID: 33368843 DOI: 10.1111/aej.12481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 12/02/2020] [Accepted: 12/08/2020] [Indexed: 11/26/2022]
Abstract
This study aimed to evaluate the influence of large apical preparations with Reciproc (REC), Hyflex CM (HCM) and Twisted File Adaptive (TFA) systems using micro-computed tomography (MCT). Ninety mesiobuccal (MB) and distobuccal (DB) root canals of maxillary molars (n = 45) were scanned using MCT before and after the shaping procedures. The root canals (n = 15) were prepared until REC 40.06, HCM 40.04 and TFA 35.04. The root canal transportation (RCT), centring ability (CA), change in volume of the root canal and at different levels (VC), remaining dentine thickness (RDT), removal of dentine wall (RDW) and working time (WT) were evaluated. Data were analysed using the Kruskal-Wallis and Dunn tests, and the one-way ANOVA and Tukey tests with a level of significance set at 5%. No significant difference among the instruments was found regarding the RCT, CA, RDT, RDW and WT (P > 0.05), in larger apical preparations in curved MB and straight DB canals of maxillary molars.
Collapse
Affiliation(s)
- Ericson Janolio de Camargo
- Division of Endodontics, College of Dentistry, University Center of Várzea Grande (UNIVAG), Várzea Grande, Brazil.,Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
| | - Marco Antonio Hungaro Duarte
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
| | - Murilo Priori Alcalde
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
| | | | | | | | - Gianluca Plotino
- Department of Endodontics, Sapienza Università di Roma, Rome, Italy
| | - Rodrigo Ricci Vivan
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
| |
Collapse
|
30
|
Cuellar MRC, Velásquez-Espedilla EG, Pedrinha VF, Vivan RR, Duarte MAH, Andrade FBD. Can kinematics, file diameter, and PUI influence the intracanal decontamination and apical bacterial extrusion? Braz Oral Res 2020; 35:e003. [PMID: 33206776 DOI: 10.1590/1807-3107bor-2021.vol35.0003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Accepted: 08/19/2020] [Indexed: 11/22/2022] Open
Abstract
The present study investigated the intracanal decontamination and apical extrusion of bacteria and debris from root canals instrumented with rotary and reciprocating systems (ProDesign Logic or ProDesign R), with different file diameters and using conventional syringe irrigation (CSI) or passive ultrasonic irrigation (PUI). Eighty extracted mandibular premolars were contaminated with Enterococcus faecalis and randomly assigned to eight experimental groups according to the root canal instrumentation and irrigation technique employed (n = 10): G1: Prodesign Logic 25.06; G2: Prodesign R 25.06; G3 and G4 were instrumented with the same single-file systems, respectively, using 35.05 diameters and CSI. G5, G6, G7, and G8 were instrumented like the previous groups, but with PUI. Apically extruded debris during instrumentation was collected into pre-weighed microtubes. The weight of the empty microtube was subtracted from the final weight to establish the amount of extruded debris. Bacteria from root canals and extruded debris were collected for a microbiological evaluation of colony forming units (CFU/mL). For statistical analyses, the Mann-Whitney and Kruskal-Wallis followed by the Dunn's tests were used (α = 0.05). All instruments caused extrusion of debris. For irrigation techniques, PUI promoted greater debris and bacterial extrusion (p < 0.05). The CFU/mL count indicated that the instrumentation of the experimental groups were equally effective in the decontamination of the root canal (p > 0.05). The systems tested (regarding file diameter and kinematics) were associated with similar amounts of apically extruded debris and root canal decontamination. PUI was associated with greater debris and bacterial extrusion.
Collapse
Affiliation(s)
- Maricel Rosario Cardenas Cuellar
- Universidade de São Paulo - USP, Bauru School of Dentistry, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru, SP, Brazil
| | - Evelyn Giuliana Velásquez-Espedilla
- Universidade de São Paulo - USP, Bauru School of Dentistry, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru, SP, Brazil
| | - Victor Feliz Pedrinha
- Universidade de São Paulo - USP, Bauru School of Dentistry, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru, SP, Brazil
| | - Rodrigo Ricci Vivan
- Universidade de São Paulo - USP, Bauru School of Dentistry, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru, SP, Brazil
| | - Marco Antonio Hungaro Duarte
- Universidade de São Paulo - USP, Bauru School of Dentistry, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru, SP, Brazil
| | - Flaviana Bombarda de Andrade
- Universidade de São Paulo - USP, Bauru School of Dentistry, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru, SP, Brazil
| |
Collapse
|
31
|
De-Deus G, Cardoso ML, Simões-Carvalho M, Silva EJNL, Belladonna FG, Cavalcante DM, Oliveira DDS, Souza EM, Lopes RT, Versiani MA. Glide Path with Reciprocating Driven Pathfinding Instrument: Performance and Fracture Rate. J Endod 2020; 47:100-104. [PMID: 33045262 DOI: 10.1016/j.joen.2020.09.015] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Revised: 09/04/2020] [Accepted: 09/10/2020] [Indexed: 11/15/2022]
Abstract
INTRODUCTION This study assessed the number of mesial and distal canals of mandibular molars in which the R-Pilot pathfinding reciprocating instrument reached the working length (WL) during macro glide path procedure. Fracture and deformation rates were also evaluated. METHODS One hundred fifty-six root canals of 52 teeth were scouted to the length of the apical foramen. Then the R-Pilot instrument was positioned at the canal orifice and activated. The instrument was moved by using a pecking motion and light apical pressure. This procedure was repeated in an attempt to reach the WL. The type of fracture and/or instrument deformation was assessed by scanning electron microscopy, whereas the roots with fractured instruments were scanned through micro-computed tomography. The percentage frequency distribution of fractures, deformations, and root canals in which the R-Pilot reached the WL were recorded and statistically compared by using the Pearson's χ2 test with α = 5%. RESULTS R-Pilot instruments reached the WL in 139 root canals (89.10%), and χ2 test showed a significant difference between the observed frequencies and the expected frequencies (χ2 = 95.41, P = .000). The observed frequencies of fractures (2.56%) and deformations (1.92%) were also significantly lower than the expected (fracture: χ2 = 140.41, P = .000; deformation: χ2 = 144.23, P = .000). Fractures occurred mostly at the apical and curved parts of the root canals. CONCLUSIONS R-Pilot reached the WL in 89.10% of the root canals of mandibular molars with fracture and deformation rates of 2.56% and 1.92%, respectively.
Collapse
Affiliation(s)
- Gustavo De-Deus
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | - Milla Lessa Cardoso
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | - Marco Simões-Carvalho
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| | - Emmanuel J N L Silva
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil; Department of Endodontics, Grande Rio University, Duque de Caxias, Rio de Janeiro, Brazil
| | | | | | | | - Erick Miranda Souza
- Department of Dentistry II, Federal University of Maranhão, São Luís, Maranhão, Brazil
| | - Ricardo Tadeu Lopes
- Nuclear Engineering Program, Federal University of Rio de Janeiro, Rio de Janeiro, Rio de Janeiro, Brazil
| | - Marco Aurélio Versiani
- Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil
| |
Collapse
|
32
|
Alberton CS, Tomazinho FSF, Calefi PS, Duarte MAH, Vivan RR, Baratto-Filho F. Influence of the Preparation Order in Four-Canal Maxillary Molars with WaveOne Gold System. J Endod 2020; 46:1291-1296. [DOI: 10.1016/j.joen.2020.05.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 05/18/2020] [Accepted: 05/27/2020] [Indexed: 12/12/2022]
|
33
|
Lopes WSP, Vieira VTL, Silva EJNL, Silva MCD, Alves FRF, Lopes HP, Pires FR. Bending, buckling and torsional resistance of rotary and reciprocating glide path instruments. Int Endod J 2020; 53:1689-1695. [PMID: 32767775 DOI: 10.1111/iej.13385] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 07/31/2020] [Accepted: 08/04/2020] [Indexed: 11/27/2022]
Abstract
AIM To evaluate the bending, buckling and torsional resistance of ProGlider (PG) (Dentsply Sirona, Ballaigues, Switzerland), R-Pilot (RP) (VDW, Munich, Germany) and WaveOne Gold Glider (WOGG) (Dentsply Sirona). METHODOLOGY Ninety instruments were used: 30 PG (size 0.16, .02v taper), 30 RP (size 0.125, .04 taper) and 30 WOGG (size 0.15, .02v taper). The bending resistance test was performed on 10 randomly selected instruments of each system according to ISO 3630-1 specifications. For the buckling resistance test, a loading was applied in the axial direction of each instrument using a universal test machine, with a 20 N cell and 15 mm min-1 speed, in the axial direction. When a lateral elastic displacement of 1 mm occurred, the force was registered. The torsional resistance test was performed according to ISO 3630-1 specifications. Statistical analysis was performed using one-way anova and post hoc Student-Newman-Keuls test (P < 0.05). RESULTS WOGG had the lowest bending resistance, whilst RP had the highest bending resistance (P < 0.05). RP also had the highest buckling resistance, and WOGG had the lowest (P < 0.05). PG had intermediate results regarding bending and buckling resistance, with significant differences to RP and WOGG (P < 0.05). RP had the highest torsional strength and the lowest angular deflection when compared to PG and WOGG (P < 0.05). No differences in the torsional strength and angular deflection were observed between WOGG and PG (P> 0.05). CONCLUSION The glide path instruments had different behaviours in term of bending, buckling and torsional resistance.
Collapse
Affiliation(s)
- W S P Lopes
- Department of Endodontics, School of Dentistry, UNESA - Estácio de Sá University, Rio de Janeiro, Brazil
| | - V T L Vieira
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - E J N L Silva
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - M C D Silva
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - F R F Alves
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - H P Lopes
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - F R Pires
- Department of Endodontics, School of Dentistry, UNESA - Estácio de Sá University, Rio de Janeiro, Brazil
| |
Collapse
|
34
|
The Influence of Brushing Movement on Geometrical Shaping Outcomes: A Micro-CT Study. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10144805] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Brushing motion has been proposed for endodontic single-file reciprocating systems to eliminate coronal interferences, but it may hesitate in a less conservative root canal shaping. The aim of the study was to compare the maintenance of the original root canal anatomy using the WaveOne Gold (WOG) technique with or without a brushing motion. Sixty extracted human mandibular first molars were selected. Manual canal scouting and mechanical glide path were performed. Samples were randomized into two groups (n = 30): WOG Primary was used to shape the mesio-lingual canals without (NB group) or with (B group) an intentional brushing motion. Specimens were scanned with micro-computed tomography (micro-CT) before and after instrumentation in order to match the volumes. Increases in canal volume and surface area were measured. Centroid shift and thickness of removed dentine from the inner curvature were assessed at the furcation, 1.5 mm and 3 mm apically from the furcation, and in relation to the point of maximum curvature. Data were analyzed by one-way ANOVA and post-hoc Student–Newmann–Keuls tests (p < 0.05). No brushing technique resulted in being significantly associated with a better maintenance of the canal anatomy, especially in the coronal third (p < 0.05). When using the WOG system, a no-brushing technique resulted in less invasive shaping, reducing the risk of stripping.
Collapse
|
35
|
Cunha TC, Matos FDS, Paranhos LR, Bernardino ÍDM, Moura CCG. Influence of glide path kinematics during endodontic treatment on the occurrence and intensity of intraoperative and postoperative pain: a systematic review of randomized clinical trials. BMC Oral Health 2020; 20:175. [PMID: 32571285 PMCID: PMC7310418 DOI: 10.1186/s12903-020-01164-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 06/12/2020] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND Preliminary canal enlargement (glide path preparation) may play a significant role in the development of pain. The aim of this systematic review of randomized clinical trials was to assess the influence of glide path kinematics during endodontic treatment on the occurrence and intensity of intraoperative and postoperative pain. METHODS A search was performed in June 2019 in six electronic databases (PubMed, Scopus, LILACS, SciELO, Embase and Web of Science) and two grey literature databases (OpenGrey and OpenThesis). The bibliographic references of the eligible articles were also hand-searched. The included clinical studies assessed the occurrence and intensity of intraoperative and/or postoperative pain after root canal preparation without glide path preparation (WGP) or with glide path preparation using manual (M-GP), continuous rotary (CR-GP), or reciprocating (R-GP) instruments. The primary outcome was the occurrence and intensity of intraoperative and postoperative pain, while analgesic consumption was the secondary outcome. The full texts of the eligible studies were analyzed by two reviewers who performed calibration exercises to verify the risk of bias and quality of the individual studies using the Joanna Briggs Institute Critical Appraisal tool. RESULTS From 1283 identified articles, only six studies were included in the qualitative analysis of the results, with a total sample of 884 patients/teeth. Three studies presented a high risk of bias, while three studies presented a moderate risk. Two studies reported that CR-GP causes lower pain levels than M-GP and WGP, and three studies showed no differences between CR-GP and R-GP. Regarding analgesic consumption, two studies found no differences among glide path kinematics, and one study reported lower consumption for CR-GP than for M-GP. Because of the limited number of studies and methodological differences, no statistical analyses were performed for the glide path kinematics comparisons. CONCLUSIONS Compelling evidence indicating a significantly different occurrence and intensity of pain among glide path kinematics is lacking. The systematic review protocol was registered in the PROSPERO database [CRD42020139989].
Collapse
Affiliation(s)
- Thaís Christina Cunha
- Postgraduate Program in Dentistry, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - Felipe de Souza Matos
- Postgraduate Program in Dentistry, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - Luiz Renato Paranhos
- Department of Preventive and Community Dentistry, School of Dentistry, Federal University of Uberlândia, Av. Pará, 1720, Bloco 2G, sala 1, Umuarama, Uberlândia, MG, CEP 38405-320, Brazil.
| | | | | |
Collapse
|
36
|
Ramyadharshini T, Anand Sherwood I, Vigneshwar VS, Ernest Prince P, Vaanjay M. Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems. Restor Dent Endod 2020; 45:e22. [PMID: 32483539 PMCID: PMC7239674 DOI: 10.5395/rde.2020.45.e22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 10/25/2019] [Accepted: 11/21/2019] [Indexed: 11/11/2022] Open
Abstract
Objectives This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.
Collapse
Affiliation(s)
| | - Inbaraj Anand Sherwood
- Department of Conservative Dentistry and Endodontics, CSI College of Dental Sciences, Madurai, TN, India
| | - V Shanmugham Vigneshwar
- Department of Conservative Dentistry and Endodontics, CSI College of Dental Sciences, Madurai, TN, India
| | - Prakasam Ernest Prince
- Department of Conservative Dentistry and Endodontics, CSI College of Dental Sciences, Madurai, TN, India
| | - Murugadoss Vaanjay
- Department of Conservative Dentistry and Endodontics, CSI College of Dental Sciences, Madurai, TN, India
| |
Collapse
|
37
|
Plotino G, Nagendrababu V, Bukiet F, Grande NM, Veettil SK, De-Deus G, Aly Ahmed HM. Influence of Negotiation, Glide Path, and Preflaring Procedures on Root Canal Shaping-Terminology, Basic Concepts, and a Systematic Review. J Endod 2020; 46:707-729. [PMID: 32334856 DOI: 10.1016/j.joen.2020.01.023] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Revised: 12/24/2019] [Accepted: 01/28/2020] [Indexed: 12/19/2022]
Abstract
INTRODUCTION Negotiation, glide path, and preflaring are essential steps in root canal shaping procedures. This report aimed to discuss the terminology, basic concepts, and clinical considerations of negotiation, glide path, and preflaring procedures and the influence of these steps on root canal shaping. METHODS This systematic review was undertaken following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The protocol has been registered with the International Prospective Register of Systematic Reviews (number CRD42019127021). A comprehensive literature search was performed by 2 independent reviewers using a selected search strategy in 2 electronic databases (PubMed and Scopus) until January 28, 2019. A further search was performed manually in endodontic journals. Studies investigating or comparing at least 1 shaping property resulting from root canal instrumentation with a glide path or preflaring in human extracted teeth or clinical studies were included. RESULTS The literature shows that the definition of glide path and preflaring procedures remains controversial, which requires an elaboration in the American Association of Endodontists' Glossary of Endodontic Terms. After the removal of irrelevant and duplicated articles, 98 articles were included. The impact of glide path preparation and preflaring on working length determination, apical file size determination, canal transportation, separation of endodontic files, shaping time, dentinal microcrack formation, and extrusion of debris was discussed. Because of heterogeneity among the included studies, quantitative synthesis was not performed for most of the parameters. CONCLUSIONS An evidence-based guideline is needed to define and correlate the basic concepts and current applications of each step of contemporary advancements in root canal instruments. Glide path preparation reduces the risk of debris extrusion, has no influence on the incidence of dentinal crack formation, and improves the preservation of the original canal anatomy. The creation of a glide path may have no impact on Reciproc files (VDW, Munich, Germany) in reaching the full working length. Preflaring increases the accuracy of working length determination. Further randomized clinical trials are required to evaluate the effect of a glide path and preflaring on root canal treatment outcomes.
Collapse
Affiliation(s)
| | - Venkateshbabu Nagendrababu
- Division of Clinical Dentistry, School of Dentistry, International Medical University, Kuala Lumpur, Malaysia
| | - Frederic Bukiet
- Aix Marseille University, CNRS, ISM, Inst Movement Sci, Marseille, France; APHM, Hôpital Timone, Service d'Odontologie, Marseille, France
| | | | - Sajesh K Veettil
- School of Pharmacy, International Medical University, Kuala Lumpur, Malaysia
| | - Gustavo De-Deus
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - Hany Mohamed Aly Ahmed
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia.
| |
Collapse
|
38
|
de-Figueiredo FED, Lima LF, Lima GS, Oliveira LS, Ribeiro MA, Brito-Junior M, Correa MB, Sousa-Neto M, Faria e Silva AL. Apical periodontitis healing and postoperative pain following endodontic treatment with a reciprocating single-file, single-cone approach: A randomized controlled pragmatic clinical trial. PLoS One 2020; 15:e0227347. [PMID: 32012166 PMCID: PMC6996828 DOI: 10.1371/journal.pone.0227347] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2019] [Accepted: 12/15/2019] [Indexed: 12/18/2022] Open
Abstract
This trial assessed post-operative pain and healing of apical periodontitis following endodontic therapy with a reciprocating system compared to a crown-down technique with hand files and lateral compaction filling. One-hundred and twenty nonvital anterior teeth with apical periodontitis were randomly treated using either a reciprocating single file followed by matching-taper single-cone filling or a hand file and lateral compaction filling. Postoperative pain was assessed during the 7 days after the treatment, using a visual analogue scale and a verbal rating scale. Apical healing was assessed using the periapical index score after a 12-month follow-up. The hypothesis tested was that both protocols were equivalent and present similar effectiveness in healing periapical lesions. Data were analyzed through two one-sided tests, t-tests, as well as Mann-Whitney and Chi-squared tests (α = 0.05). Logistic regression was used to investigate the association of clinical and demographic factors with the success of treatment. Regardless of the assessment time, no difference in incidence (38%-43% at first 24h), intensity of postoperative pain, and incidence of flare-up (≈ 3%) was observed between the two endodontic protocols. Both protocols resulted in a similar healing rate of apical periodontitis. After 12 months, the success rate ranged from 73% to 78% and the difference between the treatments fell within the pre-established equivalence margin (-0.1; -0.41 to 0.2). Endodontic treatment combining a reciprocating single file with matching-taper single cone showed similar clinical effectiveness to the treatment using hand-file instrumentation and the lateral compaction filling.
Collapse
Affiliation(s)
| | - Laila Fernandes Lima
- Graduate Program in Dentistry, Federal University of Sergipe, Aracaju, Sergipe, Brazil
| | - Giana Silveira Lima
- Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil
| | - Ludmila Smith Oliveira
- Graduate Program in Health Sciences, Federal University of Sergipe, Aracaju, Sergipe, Brazil
| | | | - Manoel Brito-Junior
- Department of Dentistry, State University of Montes Claros, Montes Claros, MG, Brazil
| | - Marcos Brito Correa
- Department of Restorative Dentistry and Dental Materials, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil
| | - Manoel Sousa-Neto
- Department of Restorative Dentistry, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil
| | | |
Collapse
|
39
|
Park SJ, Park SH, Cho KM, Ji HJ, Lee EH, Kim JW. Comparison of vibration characteristics of file systems for root canal shaping according to file length. Restor Dent Endod 2020; 45:e51. [PMID: 33294416 PMCID: PMC7691267 DOI: 10.5395/rde.2020.45.e51] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/30/2020] [Accepted: 08/04/2020] [Indexed: 12/03/2022] Open
Abstract
Objectives No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems. Materials and Methods A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%. Results In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups. Conclusions In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.
Collapse
Affiliation(s)
- Seong-Jun Park
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| | - Se-Hee Park
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| | - Kyung-Mo Cho
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| | - Hyo-Jin Ji
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| | - Eun-Hye Lee
- Department of Conservative Dentistry, Hanyang University Seoul Hospital, Seoul, Korea
| | - Jin-Woo Kim
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| |
Collapse
|
40
|
Maniglia-Ferreira C, de Almeida Gomes F, Ximenes T, Neto MAT, Arruda TE, Ribamar GG, Herculano LFG. Influence of reuse and cervical preflaring on the fracture strength of reciprocating instruments. Eur J Dent 2019; 11:41-47. [PMID: 28435364 PMCID: PMC5379833 DOI: 10.4103/ejd.ejd_272_16] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objective: This study sought to assess the influence of cervical preflaring and reuse after resterilization, on fracture strength and plastic deformation and/or surface cracking in reciprocating nickel–titanium [NiTi] endodontic instruments after root canal instrumentation of extracted human teeth. Materials and Methods: Forty engine-driven reciprocating NiTi instruments (20 Reciproc® [RC], VDW; 20 WaveOne® [WO], Dentsply) were used in root canal instrumentation of extracted human molars. A total of 485 human upper molars with similar anatomical features were selected and randomly distributed across four groups according to the instrumentation procedures performed (G1 and G3: RC; G2 and G4: WO). Reciprocating instruments were used as per manufacturer instructions. In groups G3 and G4, cervical preflaring was performed prior to instrumentation. After each use of each instrument, sterilization was repeated and scanning electron microscope (SEM) images were obtained to check for plastic deformations and/or cracks on instrument surfaces. Each instrument was used repeatedly until fracture occurred. Results: Regardless of flaring, RC files exhibited greater fracture strength than WO instruments (P <0.01) with and without preflaring. Cervical preflaring significantly reduced the risk of instrument fracture (P <0.01). No plastic deformations were observed before fracturing. However, cracks were found on WO instruments shortly after their first use. RC and WO instruments resisted fracturing after autoclave sterilization. Conclusions: Cervical preflaring allowed a significant increase in the number of times RC and WO files could be reused safely.
Collapse
Affiliation(s)
| | - Fabio de Almeida Gomes
- Department of Endodontics, Course of Dentistry, University of Fortaleza, Fortaleza, CE, Brazil
| | - Tatyana Ximenes
- Department of Endodontics, Course of Dentistry, University of Fortaleza, Fortaleza, CE, Brazil
| | | | - Thiane Elys Arruda
- Department of Endodontics, Course of Dentistry, University of Fortaleza, Fortaleza, CE, Brazil
| | - Giovani Gonçalves Ribamar
- Department of Metallurgical and Materials Engineering, Faculty of Chemical Engineering, Federal University of Ceará, Fortaleza, CE, Brazil
| | - Luis Flávio Gaspar Herculano
- Department of Metallurgical and Materials Engineering, Faculty of Chemical Engineering, Federal University of Ceará, Fortaleza, CE, Brazil
| |
Collapse
|
41
|
Machado R, Comparin D, Back EDEE, Garcia LDFR, Alberton LR. Residual smear layer after root canal instrumentation by using Niti, M-Wire and CM-Wire instruments: A scanning electron microscopy analysis. Eur J Dent 2019; 12:403-409. [PMID: 30147407 PMCID: PMC6089052 DOI: 10.4103/ejd.ejd_259_17] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Objective: The purpose of this study was to compare the amount of residual smear layer after root canal instrumentation by using Ni-Ti, M-Wire, and CM-Wire instruments. Materials and Methods: Seventy-two mandibular incisors were randomly divided into six groups according to the system used: WaveOne (WO), Reciproc (RP), Unicone (UC), ProTaper Next (PN), Mtwo (MT), and HyFlex (HF). Afterward, the specimens were cleaved in the mesiodistal and buccolingual direction for analysis by scanning electron microscopy. Results: Considering both directions and root canal thirds, there was no difference between HF, MT, and PN. RP, UC, and WO presented a significant difference between the directions, and the cervical third showed a significantly smaller quantity of residual smear layer compared with the apical third. When the systems were compared among them, there was a significant difference only between RP and WO. Conclusions: Residual smear layer observed after instrumentation with the different systems was similar, except for quantities between the reciprocating systems.
Collapse
Affiliation(s)
- Ricardo Machado
- Clinical Practice Limited to Endodontics, Navegantes, Santa Catarina, Brazil
| | - Daniel Comparin
- Clinical Practice Limited to Endodontics, Cunha Porã, Santa Catarina, Brazil
| | | | - Lucas da Fonseca Roberti Garcia
- Department of Dentistry, Division of Endodontics, Health Sciences Center, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Luiz Rômulo Alberton
- Department of Veterinary Medicine, Graduate Program in Animal Science, Paranaense University - UNIPAR, Umuarama, Paraná, Brazil
| |
Collapse
|
42
|
Reciproc and Reciproc Blue in the removal of bioceramic and resin-based sealers in retreatment procedures. Clin Oral Investig 2019; 24:405-416. [DOI: 10.1007/s00784-019-02956-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Accepted: 05/07/2019] [Indexed: 12/12/2022]
|
43
|
Feghali M, Jabbour E, Koyess E, Sabbagh J. Scanning electron microscopy evaluation of debris and smear layer generated by two instruments used in reciprocating motion WaveOne Gold® and Reciproc Blue®. AUST ENDOD J 2019; 45:388-393. [PMID: 30770606 DOI: 10.1111/aej.12338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/03/2019] [Indexed: 10/27/2022]
Abstract
The aim was to evaluate debris and smear layer at 1, 3 and 5 mm from the foramen of single-file systems WaveOne Gold® and Reciproc Blue®. Thirty single-rooted teeth were prepared using one of the following NiTi instruments WaveOne Gold® and Reciproc Blue®. Root canals were observed under a scanning electron microscope. The presence of debris and smear layer at the apical third of root canals was evaluated. Data were analysed by Friedman and Wilcoxon tests. WaveOne Gold® produced significantly less debris and smear layer compared to Reciproc Blue®. However, the mean amount of debris was significantly different within distances for WaveOne Gold®, while no difference were observed for Reciproc Blue. The mean amount of smear layer was not significantly different within distances with WaveOne Gold® and Reciproc Blue®. Both systems showed debris and smear layer in the apical third; nevertheless, WaveOne Gold® showed better results.
Collapse
Affiliation(s)
- Maya Feghali
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry, Lebanese University, Beirut, Lebanon
| | - Edgard Jabbour
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry, Lebanese University, Beirut, Lebanon
| | - Edmond Koyess
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry, Lebanese University, Beirut, Lebanon
| | - Joseph Sabbagh
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry, Lebanese University, Beirut, Lebanon
| |
Collapse
|
44
|
Santos CB, Simões‐Carvalho M, Perez R, Vieira VTL, Antunes HS, Cavalcante DF, De‐Deus G, Silva EJNL. Torsional fatigue resistance of R‐Pilot and WaveOne Gold Glider NiTi glide path reciprocating systems. Int Endod J 2019; 52:874-879. [DOI: 10.1111/iej.13068] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2018] [Accepted: 12/21/2018] [Indexed: 11/30/2022]
Affiliation(s)
- C. B. Santos
- Department of Endodontics Fluminense Federal University (UFF) NiteróiBrazil
| | - M. Simões‐Carvalho
- Department of Endodontics Fluminense Federal University (UFF) NiteróiBrazil
| | - R. Perez
- Department of Endodontics Fluminense Federal University (UFF) NiteróiBrazil
| | - V. T. L. Vieira
- Department of Endodontics School of Dentistry Grande Rio University (UNIGRANRIO) Rio de Janeiro Brazil
| | - H. S. Antunes
- Department of Endodontics School of Dentistry Grande Rio University (UNIGRANRIO) Rio de Janeiro Brazil
| | - D. F. Cavalcante
- Department of Endodontics Fluminense Federal University (UFF) NiteróiBrazil
| | - G. De‐Deus
- Department of Endodontics Fluminense Federal University (UFF) NiteróiBrazil
| | - E. J. N. L. Silva
- Department of Endodontics Fluminense Federal University (UFF) NiteróiBrazil
- Department of Endodontics School of Dentistry Grande Rio University (UNIGRANRIO) Rio de Janeiro Brazil
| |
Collapse
|
45
|
Martins CM, De Souza Batista VE, Andolfatto Souza AC, Andrada AC, Mori GG, Gomes Filho JE. Reciprocating kinematics leads to lower incidences of postoperative pain than rotary kinematics after endodontic treatment: A systematic review and meta-analysis of randomized controlled trial. J Conserv Dent 2019; 22:320-331. [PMID: 31802813 PMCID: PMC6873607 DOI: 10.4103/jcd.jcd_439_18] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Background: Extrusion of infected debris into the periapical tissue has been cited as the major cause of postoperative pain, regardless of instrumentation technique. Aim: Comprehensively review two different kinematics of instrumentation (reciprocating and rotary) and association to the postoperative pain after endodontic treatment. Methods: Two investigators performed a systematic review with meta-analysis. MEDLINE/PubMed, Cochrane Library, and Scopus supplied relevant data from studies published until February 2018 to answer the PICO question. Primary outcome was overall postoperative pain, and the secondary outcomes were nature of the pain (mild, moderate, and severe) at 12, 24, and 48 h. Results: Ten randomized clinical trials fulfilled eligibility criteria, and five of them were submitted in the meta-analysis. Primary outcome indicated that reciprocating system results in less postoperative pain compared to rotary system (P < 0.05). As a secondary outcome, there was no statistical difference for mild, moderate, and severe pain after 12 and 24 h using reciprocating or rotary systems (P > 0.05). However, the reciprocation system showed less severe pain after 48 h (P < 0.05). Conclusion: Rotary motion had a negative impact on postoperative pain after endodontic treatment. Furthermore, after 48 h, more patients presented severe pain under rotary motion. More randomized clinical studies would be helpful.
Collapse
Affiliation(s)
- Christine Men Martins
- Department of Dentistry, Dental School of Presidente Prudente, University of Western São Paulo, Presidente Prudente, Sao Paulo, Brazil
| | - Victor Eduardo De Souza Batista
- Department of Dentistry, Dental School of Presidente Prudente, University of Western São Paulo, Presidente Prudente, Sao Paulo, Brazil
| | | | - Ana Cristina Andrada
- Department of Endodontics, University of Detroit Mercy School of Dentistry, Detroit, Michigan, USA
| | - Graziela Garrido Mori
- Department of Dentistry, Dental School of Presidente Prudente, University of Western São Paulo, Presidente Prudente, Sao Paulo, Brazil
| | - João Eduardo Gomes Filho
- Department of Dentistry, Dental School of Presidente Prudente, University of Western São Paulo, Presidente Prudente, Sao Paulo, Brazil
| |
Collapse
|
46
|
Keskin C, Sivas Yilmaz Ö, Inan U, Özdemir Ö. Postoperative pain after glide path preparation using manual, reciprocating and continuous rotary instruments: a randomized clinical trial. Int Endod J 2018; 52:579-587. [DOI: 10.1111/iej.13053] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2018] [Accepted: 12/03/2018] [Indexed: 11/29/2022]
Affiliation(s)
- C. Keskin
- Department of Endodontics Faculty of Dentistry Ondokuz Mayıs University Samsun Turkey
| | - Ö. Sivas Yilmaz
- Department of Endodontics Faculty of Dentistry Ondokuz Mayıs University Samsun Turkey
| | - U. Inan
- Department of Endodontics Faculty of Dentistry Ondokuz Mayıs University Samsun Turkey
| | - Ö. Özdemir
- Miadent Oral and Dental Health Center Ankara Turkey
| |
Collapse
|
47
|
Neelakantan P, Ahmed HMA, Chang JWW, Nabhan MS, Wei X, Cheung GSP, Gomes BPFA. Effect of instrumentation systems on endotoxin reduction from root canal systems: A systematic review of clinical studies and meta‐analysis. AUST ENDOD J 2018; 45:407-413. [DOI: 10.1111/aej.12333] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/03/2018] [Indexed: 11/26/2022]
Affiliation(s)
- Prasanna Neelakantan
- Discipline of Endodontology Faculty of Dentistry The University of Hong Kong Hong Kong Hong Kong
| | - Hany Mohamed Aly Ahmed
- Department of Restorative Dentistry Faculty of Dentistry University of Malaya Kuala Lumpur Malaysia
| | - Jeffrey Wen Wei Chang
- Discipline of Endodontology Faculty of Dentistry The University of Hong Kong Hong Kong Hong Kong
| | - Mohamed Shady Nabhan
- Department of Prosthetic Dentistry Faculty of Dentistry Ain Shams University Cairo Egypt
| | - Xi Wei
- Department of Operative Dentistry and Endodontics Guanghua School of Stomatology, Affiliated Stomatological Hospital Guangdong Provincial Key Laboratory of Stomatology Sun Yat‐sen University Guangzhou China
| | - Gary Shun Pan Cheung
- Discipline of Endodontology Faculty of Dentistry The University of Hong Kong Hong Kong Hong Kong
| | - Brenda P. F. A. Gomes
- Department of Restorative Dentistry Endodontics Division Piracicaba Dental School State University of Campinas ‐ UNICAMP Piracicaba São Paulo Brazil
| |
Collapse
|
48
|
Iacono F, Pirani C, Arias A, de la Macorra JC, Generali L, Gandolfi MG, Prati C. Impact of a modified motion on the fatigue life of NiTi reciprocating instruments: a Weibull analysis. Clin Oral Investig 2018; 23:3095-3102. [PMID: 30397734 DOI: 10.1007/s00784-018-2730-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 10/22/2018] [Indexed: 10/27/2022]
Abstract
OBJECTIVES To evaluate the impact of a modified motion on the fatigue life of four brands of nickel-titanium (NiTi) reciprocating instruments. MATERIALS AND METHODS Cyclic fatigue (CF) resistance of 160 instruments was evaluated in an artificial stainless-steel canal (90° angle, 5-mm radius of curvature). WaveOne and WaveOne Gold (Denstply Maillefer, Baillagues, Switzerland) and Reciproc and Reciproc Blue (VDW, Munich, Germany) were tested with two different motions: (1) X-Smart Plus (Denstply Maillefer) endodontic motor and (2) a 4:1 contra-angle with an experimental motion (EVO) with different rotation angles and based on a sinusoidal acceleration. Motions with X-Smart Plus and EVO were recorded and analyzed at a reduced speed with VLC Media Player software for a more accurate analysis. Mean half-life, beta, and eta Weibull parameters were determined and compared. RESULTS Reciproc Blue resulted the most resistant instruments either with EVO or X-Smart. WaveOne Gold lasted significantly longer than WaveOne with EVO (probability of 91%) while no significant differences were found with X-Smart. Considering NCF, Reciproc, WaveOne Gold, and Reciproc Blue lasted significantly longer with EVO (probabilities of 66%, 80%, and 89% respectively). WaveOne Gold showed the highest beta parameter. CONCLUSIONS The experimental motion was found to have a positive impact on fatigue lifetime of reciprocating instruments. CLINICAL RELEVANCE Current findings provide insight for future improvements in the clinical use of reciprocating files. Experimental motions may be considered when searching for additional strategies in order to increase the safer use of NiTi files during endodontic procedures.
Collapse
Affiliation(s)
- Francesco Iacono
- School of Dentistry, Endodontic Clinical Section, Master in Clinical Endodontology, Department of Biomedical and Neuromotor Sciences(DIBINEM), University of Bologna, Alma Mater Studiorum, Bologna, Italy
| | - Chiara Pirani
- School of Dentistry, Endodontic Clinical Section, Master in Clinical Endodontology, Department of Biomedical and Neuromotor Sciences(DIBINEM), University of Bologna, Alma Mater Studiorum, Bologna, Italy.
| | - Ana Arias
- Department of Conservative and Prosthetic Dentistry, School of Dentistry, Complutense University, Madrid, Spain
| | - Josè C de la Macorra
- Department of Conservative and Prosthetic Dentistry, School of Dentistry, Complutense University, Madrid, Spain
| | - Luigi Generali
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance (CHIMOMO), School of Dentistry, Endodontic Section, University of Modena and Reggio Emilia, Modena, Italy
| | - Maria Giovanna Gandolfi
- School of Dentistry, Endodontic Clinical Section, Master in Clinical Endodontology, Department of Biomedical and Neuromotor Sciences(DIBINEM), University of Bologna, Alma Mater Studiorum, Bologna, Italy
| | - Carlo Prati
- School of Dentistry, Endodontic Clinical Section, Master in Clinical Endodontology, Department of Biomedical and Neuromotor Sciences(DIBINEM), University of Bologna, Alma Mater Studiorum, Bologna, Italy
| |
Collapse
|
49
|
Gavini G, Santos MD, Caldeira CL, Machado MEDL, Freire LG, Iglecias EF, Peters OA, Candeiro GTDM. Nickel-titanium instruments in endodontics: a concise review of the state of the art. Braz Oral Res 2018; 32:e67. [PMID: 30365608 DOI: 10.1590/1807-3107bor-2018.vol32.0067] [Citation(s) in RCA: 103] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2018] [Accepted: 06/11/2018] [Indexed: 11/22/2022] Open
Abstract
The introduction of automated instrumentation in endodontics represented a major advance in progress for this specialty, with improvements in the quality and predictability of root canal preparation and a significant reduction in procedural errors. In recent years, endodontic instruments have undergone a series of changes brought about by modifications in design, surface treatments, and thermal treatments. In addition, new movements have also been incorporated to offer greater safety and efficiency, optimizing the properties of the NiTi alloy, especially through eccentric rotary motion. An understanding of the mechanical properties of these new NiTi instruments and their effect on the clinical performance of root canal preparation is essential if dental practitioners are to select the instruments that provide optimal clinical outcomes, especially in curved or flattened canals. The objective of this literature review is to present and discuss the characteristics of the NiTi alloys used in the major instrumentation systems available in the market, as well as the influence of the metallurgical and mechanical properties of NiTi instruments and the movements that drive them, to enable more accurate and predictable planning of root canal preparation.
Collapse
Affiliation(s)
- Giulio Gavini
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | - Marcelo Dos Santos
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | - Celso Luis Caldeira
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | | | - Laila Gonzales Freire
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | - Elaine Faga Iglecias
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | - Ove Andrea Peters
- University of the Pacific, Arthur A. Dugoni School of Dentistry, Department of Endodontics, San Francisco, CA, United States
| | | |
Collapse
|
50
|
Plotino G, Grande NM, Testarelli L, Gambarini G, Castagnola R, Rossetti A, Özyürek T, Cordaro M, Fortunato L. Cyclic Fatigue of Reciproc and Reciproc Blue Nickel-titanium Reciprocating Files at Different Environmental Temperatures. J Endod 2018; 44:1549-1552. [DOI: 10.1016/j.joen.2018.06.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2018] [Revised: 06/03/2018] [Accepted: 06/07/2018] [Indexed: 11/29/2022]
|