1
|
Kim DH, Choi YW, Kang S, Shin SJ, Jung IY. Postoperative pain of minimally invasive root canal treatment:a randomized clinical trial. Odontology 2024; 112:1307-1315. [PMID: 38429393 DOI: 10.1007/s10266-024-00912-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Accepted: 02/07/2024] [Indexed: 03/03/2024]
Abstract
This randomized clinical trial compared postoperative pain between a minimally invasive (MP) and conventional root canal treatment protocol (CP). A total of 170 mature permanent teeth (either with vital or necrotic pulp), were randomly assigned into two groups. In the CP group, ProTaper Gold (Dentsply Sirona, Ballaigues, Switzerland) and a continuous wave of condensation technique were used, whereas, in the MP group, TruNatomy (Dentsply Sirona), ultrasonic-assisted irrigation (UI), calcium hydroxide, and a sealer-based obturation technique were used. Patients recorded preoperative and postoperative pain using a 0-10 numerical rating scale (NRS) at 4 h, 1, 2, 3, 4, 5, 6, and 7 days after instrumentation and 1 day after canal obturation, respectively. There were no significant differences in pain intensity at any time points assessed between the two groups (p > 0.05). The occurrence of moderate/intense pain after instrumentation was significantly associated with preoperative periapical index (PAI) (p = 0.017) and NRS scores (p < 0.001). Preoperative pulp status (p = 0.009) and NRS score (p = 0.006) were identified as significant factors in the occurrence of moderate/intense pain after obturation. Instrumentation unequivocally reduced pain severity for both groups. The post-endodontic pain associated with the use of MP, combined with UI, Ca(OH)2, and calcium-silicate cement, did not differ from that of CP. Preoperative pain score, PAI, and preoperative pulp status were determined to be prognostic factors for postoperative pain.
Collapse
Affiliation(s)
- Do-Hyun Kim
- Department of Conservative Dentistry and Oral Science Research Center, Microscope Center, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Sudaemun-gu, Seoul, 03722, Korea
| | - Yoon-Woo Choi
- Department of Conservative Dentistry and Oral Science Research Center, Microscope Center, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Sudaemun-gu, Seoul, 03722, Korea
| | - Sumi Kang
- Department of Conservative Dentistry and Oral Science Research Center, Microscope Center, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Sudaemun-gu, Seoul, 03722, Korea
| | - Su-Jung Shin
- Department of Conservative Dentistry, Gangnam Severance Dental Hospital, Yonsei University, Seoul, Korea
| | - Il-Young Jung
- Department of Conservative Dentistry and Oral Science Research Center, Microscope Center, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Sudaemun-gu, Seoul, 03722, Korea.
| |
Collapse
|
2
|
Copelli FA, Oda LY, Rodrigues CT, Batista A, Duarte MAH, Cavenago BC. Evaluation of Minimally Invasive Preparation of Curved Mesial Canals of Mandibular Molars - An In Vitro Study. J Endod 2024; 50:1321-1326. [PMID: 38901644 DOI: 10.1016/j.joen.2024.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 05/29/2024] [Accepted: 06/06/2024] [Indexed: 06/22/2024]
Abstract
INTRODUCTION Curved mesial roots can be challenging for different stages of endodontic treatment. Preparation aims to enlarge, clean, and shape the root canal system, and hundreds of systems are available to carry it out. Aiming to maintain pericervical dentin, minimally invasive preparation was proposed, and with it, instruments with lower tapers emerged. This study aimed to evaluate the increase in canal volume, the centering ability of the instruments, and root canal transportation of two different rotary systems with lower tapers. METHODS Eighteen curved mesial roots of extracted mandibular molars were scanned by micro-CT at 3 moments: initial and after the 2 stages of endodontic preparation. The canals were prepared using TruNatomy (TN) and ProDesign Logic 2 (PDL2) instruments up to sizes 25.04 and 26.04, respectively, and after 36.03 and 35.05, respectively. The data were analyzed using parametric and nonparametric tests with a significance level of 5%. RESULTS TN and PDL2 systems showed no difference regarding the increase in the volume of the canals with the first instruments, but after preparation with a diameter size of 35 or 36, there was a difference (P < .01) between the systems in the cervical and middle thirds. CONCLUSION Both systems shaped the mesial canals of mandibular molars while keeping low transportation and good centering ability in enlargements up to diameter size 35 or 36 with tapers of 3 or 5%.
Collapse
Affiliation(s)
- Felipe Andretta Copelli
- Department of Restorative Dentistry, Postgraduate Program in Dentistry of Federal University of Paraná, Curitiba, Paraná, Brazil
| | - Lisa Yurie Oda
- Department of Restorative Dentistry, Postgraduate Program in Dentistry of Federal University of Paraná, Curitiba, Paraná, Brazil.
| | | | - Antonio Batista
- Department of Restorative Dentistry, Federal University of Paraná, Curitiba, Paraná, Brazil
| | - Marco Antonio Hungaro Duarte
- Department of Operative Dentistry, Endodontics and Dental Materials, School of Dentistry of Bauru, University of São Paulo, São Paulo, Brazil
| | - Bruno Cavalini Cavenago
- Department of Restorative Dentistry, Postgraduate Program in Dentistry of Federal University of Paraná, Curitiba, Paraná, Brazil
| |
Collapse
|
3
|
Sharma A, Nirupama DN, Nainan MT, Vijay R, Thomas H, Yasin S. Quantitative evaluation of the apically extruded debris from root canals prepared by single-file rotary and reciprocating file systems: An in vitro study. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:860-865. [PMID: 39372569 PMCID: PMC11451691 DOI: 10.4103/jcde.jcde_275_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Revised: 06/28/2024] [Accepted: 06/28/2024] [Indexed: 10/08/2024]
Abstract
Aim The aim is to investigate and compare the amount of apically extruded debris after root canal preparation using single rotary and reciprocating file system. Materials and Methods Forty single-rooted human mandibular premolars with straight canals were randomly assigned to four groups (n = 10). The root canals were instrumented according to the manufacturers' instructions using single-rotary file systems Hyflex EDM (HEDM), One Shape (OS) and single-reciprocating file systems Wave OneGold (WOG) and OneRECI (OR). The apically extruded debris was collected in preweighed glass vials using the Myers and Montgomery method. After drying, the mean weight of the extruded debris was assessed using a microbalance. Results and Conclusions Multiple comparison between groups demonstrated that the mean weight of apically extruded debris in the HEDM group was significantly less compared to all other study groups, and the differences were statistically significant (P < 0.001). Under the condition of this study, all file systems caused apical debris extrusion. The mean apically extruded debris was significantly least in HEDM, followed by WOG, OneRECI and highest in the OS group.
Collapse
Affiliation(s)
- Ayisha Sharma
- Department of Conservative Dentistry and Endodontics, Vydehi Institute of Dental Sciences and Research Centre, Bengaluru, Karnataka, India
| | - Duddi Narendra Nirupama
- Department of Conservative Dentistry and Endodontics, Vydehi Institute of Dental Sciences and Research Centre, Bengaluru, Karnataka, India
| | - Mohan Thomas Nainan
- Department of Conservative Dentistry and Endodontics, Vydehi Institute of Dental Sciences and Research Centre, Bengaluru, Karnataka, India
| | - R. Vijay
- Department of Conservative Dentistry and Endodontics, Vydehi Institute of Dental Sciences and Research Centre, Bengaluru, Karnataka, India
| | - Helen Thomas
- Department of Conservative Dentistry and Endodontics, Vydehi Institute of Dental Sciences and Research Centre, Bengaluru, Karnataka, India
| | - Sohail Yasin
- Department of Conservative Dentistry and Endodontics, Vydehi Institute of Dental Sciences and Research Centre, Bengaluru, Karnataka, India
| |
Collapse
|
4
|
Ürgüplüoğlu SN, Akıncı L, Şimşek N. Micro-computed tomography analysis of shaping ability of nickel-titanium instruments activated by continuous rotation or adaptive motion. AUST ENDOD J 2024; 50:334-340. [PMID: 38666710 DOI: 10.1111/aej.12850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 04/15/2024] [Accepted: 04/16/2024] [Indexed: 08/13/2024]
Abstract
This study assessed the ability of Twisted File Adaptive (TFA), TruNatomy (TRN) and VDW.Rotate (VR) instruments activated by continuous rotation (CR) and adaptive motion (AM) to shape curved root canals. Thirty mandibular molars with two separate mesial canals 20°-40° curved were collected and scanned using micro-computed tomography (μCT). The canals were then randomly assigned into six groups (n = 10): TRN, VR or TFA instruments activated by CR or AM. TRN groups 17.02, 20.04 and 26.04; VR groups 15.04, 20.05 and 25.06; TFA groups were shaped consecutively using 15K-file, 20.04 and 25.06. After they were shaped, the canals were scanned again. The volume of removed dentin, canal transportation and centring ratio were calculated μCT images. All data were analysed using the Kruskal-Wallis test or one-way analysis of variance (p < 0.05). With both kinematics, the TRN instrument removed the least amount of dentin, the VR-CR and the TFA-AM removed the most (p < 0.05). The transportation and centring ratios among all groups were similar (p > 0.05). The volume of dentin removed, the diameter or design features of the instruments and different kinematics did not affect the centring ratio and the amount of transportation and remained within safe limits. All three instruments activated by either kinematics were found to have similar effectiveness in shaping curved root canals.
Collapse
Affiliation(s)
| | - Levent Akıncı
- Department of Endodontics, Faculty of Dentistry, Inonu University, Malatya, Turkey
| | - Neslihan Şimşek
- Department of Endodontics, Faculty of Dentistry, Inonu University, Malatya, Turkey
| |
Collapse
|
5
|
Al Omari T, Atmeh AR, Algahtani FN, Dkmak A, Albanna RHI, Tabnjh A. The effect of irrigation solution temperature and novel heat-treated rotary files on apical debris extrusion and canal preparation time. AUST ENDOD J 2024. [PMID: 39022875 DOI: 10.1111/aej.12878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 06/27/2024] [Accepted: 07/07/2024] [Indexed: 07/20/2024]
Abstract
This study aimed to compare apical debris extrusion and canal preparation time with ProTaper Gold (PTG) and ProTaper Ultimate (PTU) files at different temperatures. Mesio-buccal roots of 60 mandibular first molars were distributed into six groups depending on the file type (PTG, PTU) and irrigation solution temperature (20, 37, 45°C). During instrumentation, extruded debris were collected and weighed to measure the mass in milligrams. The canal preparation time was recorded in seconds. ANOVA followed by Bonferroni post-hoc tests were used for analysis. The amount of debris extrusion was significantly higher in PTU, which was affected by the irrigation solution temperature (p < 0.05). The difference in canal preparation time was not significant between the two file systems, however, it was significant between the different temperatures (p = 0.001). Both file systems had shorter canal preparation times at 20°C. The irrigation solution temperature could influence the debris extrusion and time of canal preparation.
Collapse
Affiliation(s)
- Taher Al Omari
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Amre R Atmeh
- Hamdan Bin Mohammed College of Dental Medicine (HBMCDM), Mohammed Bin Rashid University of Medicine and Health Sciences (MBRU), Dubai, United Arab Emirates
| | - Fahda N Algahtani
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Alaa Dkmak
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Rami Haitham Issa Albanna
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Abedelmalek Tabnjh
- Department of Applied Dental Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| |
Collapse
|
6
|
Kaşıkçı S, Türker SA. Effect of Movement Kinematics and Heat-Treated Alloys on the Apical Extrusion of Debris: An In Vitro Study. Niger J Clin Pract 2024; 27:774-778. [PMID: 38943303 DOI: 10.4103/njcp.njcp_889_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Accepted: 05/21/2024] [Indexed: 07/01/2024]
Abstract
BACKGROUND Apically extruded debris can be affected by some features of the file systems such as kinematics or metallurgic properties. AIMS This in vitro study aimed to evaluate the effect of movement kinematics (reciprocation or rotation) and heat-treated alloys (C.Wire) on the amount of debris extrusion. METHODS Seventy-two mesiobuccal root canals were assigned into three experimental groups related to the single-file system used (n = 24): two rotational; One Shape (Conventional Ni-Ti), One Curve (C.Wire), and one reciprocating; and One Reci (C.Wire). The file systems were used according to the advisable speed and torque according to the manufacturers' suggestion. The weight of debris was calculated by subtracting the preweights from postweights of Eppendorf tubes. Kruskall-Wallis and Mann-Whitney U tests were used to analyze the data (P = 0.05). RESULTS One Shape produced the greatest amount of extruded debris compared with One Curve (P < 0.001) and One Reci (P < 0.001), respectively. No statistical difference was found between One Curve and One Reci concerning amount of apical debris extrusion (P = 0.489). CONCLUSION Metallurgical properties of files may affect apical debris extrusion. Alloy type is an important factor in the amount of debris extrusion. File kinematics does not affect apical debris extrusion.
Collapse
Affiliation(s)
- S Kaşıkçı
- Department of Endodontics, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey
| | - S A Türker
- Department of Endodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak, Turkey
| |
Collapse
|
7
|
Abdelnaby P, Ibrahim M, ElBackly R. In vitro evaluation of filling material removal and apical debris extrusion after retreatment using Reciproc blue, Hyflex EDM and ProTaper retreatment files. BMC Oral Health 2023; 23:902. [PMID: 37990209 PMCID: PMC10664678 DOI: 10.1186/s12903-023-03579-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 10/25/2023] [Indexed: 11/23/2023] Open
Abstract
OBJECTIVES To evaluate the amount of remaining filing material and apical debris extrusion after retreatment using Reciproc Blue, Hyflex EDM and ProTaper Retreatment Files. MATERIALS AND METHODS Thirty-six extracted permanent mandibular first molars with moderately curved mesial roots were selected. Mesiobuccal canals were prepared using the ProTaper Next system up to size X2 and filled using gutta-percha and Adseal sealer via cold lateral compaction. Teeth were randomly divided into three equal groups (n = 12): Group 1: Reciproc Blue (RB)(VDW, Germany), Group 2: Hyflex EDM (HEDM)(Coltene/Whaledent, Switzerland), Group 3: ProTaper Universal Retreatment file system + ProTaper Next file system (PTUR + PTN)( Dentsply Maillefer, Switzerland). Eppendorf tubes were used to collect the apically extruded debris. Cone-beam computed tomographic scans were taken prior to and after retreatment and the volume of remaining filling material was assessed at the coronal, middle and apical levels. Statistical analysis was performed using the Kruskal-Wallis test, Friedman's test and Wilcoxon Sign Rank test. Significance level was set at p value 0.05. RESULTS There were no statistically significant differences among the three groups in the reduction of the volume of the filling material or in the amount of apically extruded debris. CONCLUSION All the tested filing systems showed similar efficacy in removing the filling material, however, none of them could achieve its complete removal. Apical extrusion of debris occurred with all the systems used with no significant difference between the three groups.
Collapse
Affiliation(s)
- Passent Abdelnaby
- Conservative Dentistry Department, MS Student, Endodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Mohamed Ibrahim
- Conservative Dentistry Department, Endodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Rania ElBackly
- Conservative Dentistry Department, Endodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
- Tissue Engineering Laboratories, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| |
Collapse
|
8
|
Rajnekar R, Mankar N, Nikhade P, Chandak M. Comparative evaluation of apical debris extrusion during root canal preparation using three different rotary file systems. F1000Res 2023; 12:797. [PMID: 39220607 PMCID: PMC11362740 DOI: 10.12688/f1000research.135235.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/03/2023] [Indexed: 09/04/2024] Open
Abstract
Background: Endodontic success depends on the complete cleaning and shaping of the root canal. In order to achieve this goal, debris removal is essential. Even with improvements in instrument design, apical debris extrusion continues to be a cause of periradicular inflammation. The current study aimed to compare the amount of apically extruded debris throughout the canal instrumentation with TruNatomy, ProTaper Next, 2Shape rotary systems. Methods: A total of 60 freshly extracted single‑rooted mandibular premolars were used. An access opening was made, and a working length was estimated. The samples were arbitrarily allocated into three groups i.e. Group I: TruNatomy (n = 20), Group II: ProTaper Next (n = 20), Group III: 2Shape (n = 20). During the canal instrumentation, the extruded debris were collected in preweighed Eppendorf tubes. Post-instrumentation, the tubes were placed in a hot air oven at 140°C for five hours. For calculating the dry debris weight, the tube's pre-instrumentation weight was deducted from the post-instrumentation weight. The data was analysed using one‑way analysis of variance and post hoc Tukey's test. Results: Extrusion of debris was noted in all the specimens. TruNatomy rotary system showed least debris extrusion in comparison to ProTaper Next and 2Shape (P < 0.05). However, the results were statistically non-significant between ProTaper Next and 2Shape (P > 0.05). Conclusions: It was noted that all instruments apically extruded debris, with TruNatomy system being related to minimum extrusion.
Collapse
Affiliation(s)
- Rutuja Rajnekar
- Datta Meghe Institute of Higher Education and Research, Sawangi, Maharashtra, India
- Department of Conservative Dentistry and Endodontics, Sharad Pawar Dental College, Wardha, Maharshtra, 442001, India
| | - Nikhil Mankar
- Datta Meghe Institute of Higher Education and Research, Sawangi, Maharashtra, India
- Department of Conservative Dentistry and Endodontics, Sharad Pawar Dental College, Wardha, Maharshtra, 442001, India
| | - Pradnya Nikhade
- Datta Meghe Institute of Higher Education and Research, Sawangi, Maharashtra, India
- Department of Conservative Dentistry and Endodontics, Sharad Pawar Dental College, Wardha, Maharshtra, 442001, India
| | - Manoj Chandak
- Datta Meghe Institute of Higher Education and Research, Sawangi, Maharashtra, India
- Department of Conservative Dentistry and Endodontics, Sharad Pawar Dental College, Wardha, Maharshtra, 442001, India
| |
Collapse
|
9
|
Al Omari TMN, La Rosa GRM, Albanna RHI, Tabnjh A, Papale F, Pedullà E. The effect of different kinematics on apical debris extrusion with a single-file system. Odontology 2023; 111:910-915. [PMID: 36917401 PMCID: PMC10492679 DOI: 10.1007/s10266-023-00802-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 02/27/2023] [Indexed: 03/16/2023]
Abstract
To compare the amount of extruded debris caused by different motions using a single-file system. Fifty mandibular first molar teeth were randomized into 5 groups (n = 10) according to the motion tested: Optimize Torque Reverse (OTR), TF Adaptive Motion (TFA), continuous rotation (CR), reciprocation motion (+ 150°, -30°) (REC), and Jeni motion (Jeni). One Curve single file 25/06 (Micro-Mega, Besançon, France) was used in all experimental groups. The root canals were irrigated with 2.5% NaOCl, and the extruded debris were collected at pre-weighted glass vials. The glass vials were kept inside an incubator for one week at 70 °C to dry out the irrigating solution. The extruded debris was quantified by subtracting the pre-instrumentation from the post-instrumentation weight of the glass vials. The time required for each instrumentation procedure was digitally recorded. All data were analyzed statistically with one way ANOVA and post hoc Tukey test (P < 0.05). All the motions extruded apically debris with Jeni mode caused significantly less debris extrusion than TFA, REC, and CR (P < 0.05) while no significant difference emerged with OTR. Preparation time was not significantly different in all groups. Within the limits of the present study, all the kinematics produced apically debris extrusion, with Jeni reporting a similar amount of debris compared with OTR and significantly less than TFA, REC, and CR. Preparation time was similar among the tested kinematics.
Collapse
Affiliation(s)
- Taher M N Al Omari
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy.
| | - Rami Haitham Issa Albanna
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Abedelmalek Tabnjh
- Department of Applied Dental Science, Faculty of Applied Medical Science, Jordan University of Science and Technology, Irbid, Jordan
| | - Flavia Papale
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| |
Collapse
|
10
|
Abduljalil M, Andac G, Basmaci F. Impacts of different Nickel-Titanium rotary and reciprocating root canal preparation systems on the amount of apically extruded debris. AUST ENDOD J 2023; 49 Suppl 1:308-314. [PMID: 36571483 DOI: 10.1111/aej.12734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 07/18/2022] [Accepted: 12/18/2022] [Indexed: 12/27/2022]
Abstract
This study aimed to evaluate the amount of apically extruded debris caused by different NiTi files. One hundred mandibular premolars were included in this study. The specimens were divided into five groups (n = 20): (i) TruNatomy, (ii) WaveOne Gold, (iii) 2Shape, (iv) ProTaper Next and (v) Reciproc Blue. The extruded debris was collected into preweighed Eppendorf tubes. These tubes were weighed again, and the net weight of debris was calculated. Data were statistically analysed, and the significance level was set at 5%. The least amount of extruded debris was observed in the TruNatomy group (p < 0.05). Statistically significant differences were not found among (iii), (iv) and (v) groups (p > 0.05). However, these groups resulted in significantly higher amounts of debris when compared to (i) and (ii) groups (p < 0.05). The results lead us to conclude that all instrumentation systems caused apical extrusion of debris at varying weights.
Collapse
Affiliation(s)
- Mohamad Abduljalil
- Department of Endodontics, Faculty of Dentistry, European University of Lefke, Mersin 10, Turkey
| | - Gizem Andac
- Department of Endodontics, Faculty of Dentistry, Near East University, Mersin 10, Turkey
| | - Fatma Basmaci
- Department of Endodontics, Faculty of Dentistry, Near East University, Mersin 10, Turkey
| |
Collapse
|
11
|
Al-Saffar FB, Al-Gharrawi HA. A Comparative Evaluation of the Apically Extruded Debris from Root Canals Prepared by R-Motion NiTi File System. Int J Dent 2023; 2023:5731248. [PMID: 37152476 PMCID: PMC10156454 DOI: 10.1155/2023/5731248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/07/2023] [Accepted: 04/07/2023] [Indexed: 05/09/2023] Open
Abstract
Background Apically extruded debris (AED) is an inherent concern during root canal treatment for both endodontists and general practitioners. The present study investigates the AED of the novel R-Motion single-file reciprocating system compared to standard single reciprocating and multifile rotary systems. Materials and Methods Fifty-six moderately curved palatal roots of upper maxillary first molars were selected for the present study. The samples were then divided randomly into four groups (n = 14)- Group I: R-motion (RM), Group II: WaveOne Gold (WOG), Group III: ProTaper Next (PTN), and Group IV: HyFlex EDM (HFEDM). The researcher has modified Myers and Montgomery's method to simulate human body temperature. Vials were used to collect debris and weighted using a 0.00001 sensitive balance before and after instrumentation. The instrumentation of all experimented groups was done at 37°C, terminated at master apical file #25. An auto syringe with a side vented needle was used to deliver 8 ml of deionized water for irrigation of each sample during preparation. Vials were stored in a dry sealed desiccator which contained CaSO4 crystals, for 24 hr before weighing. The weight of the collected debris was obtained by subtracting the preinstrumentation weight from the postinstrumentation weight for each vial. The Kruskal-Wallis and Mann-Whitney U tests were performed to analyse the statistical difference in the amount of debris between the tested groups at a 0.05 significance level. Results The RM system produced less debris extrusion than all tested groups, with a significant difference between the former and the WOG and the PTN systems. However, WOG, PTN, and HFEDM showed no statistically significant difference in the amount of AED. Conclusion All tested groups produced apical debris in different amounts. The RM produced substantially less AED than WOG and PTN. Meanwhile, WOG, PTN, and HFEDM caused a comparable amount of AED.
Collapse
Affiliation(s)
- Farah B. Al-Saffar
- Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, Baghdad 10001, Iraq
| | - Hikmet A. Al-Gharrawi
- Department of Conservative Dentistry, College of Dentistry, Mustansiriyah University, Baghdad 10001, Iraq
| |
Collapse
|
12
|
Quantitative Assessment of Apically Extruded Debris after Single-Files Supplemental Retreatment considering Apical Patency Influence: In Vitro Study. Int J Biomater 2022; 2022:7544813. [PMID: 36589768 PMCID: PMC9797296 DOI: 10.1155/2022/7544813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 12/05/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022] Open
Abstract
Objective This study aims to assess the impact of re-establishing apical patency on the quantity of debris extruded through the apex after three supplementary retreatment files (TruNatomy (TRN), WaveOne Gold (WOG), and XP endo Finisher R (XPFR)). Materials and Methods Eighty single-rooted mandibular premolars were prepared with ProTaper Universal rotary systems (PTU) up to F3 and obturated. The samples were divided into two main groups according to the presence or absence of the apical patency (n = 40), GI with apical patency and GII without apical patency. Based on the file system, which was adopted to eliminate the previous filling, each group had four subgroups (n = 10). In GI PTUR and GII PTUR, ProTaper Universal retreatment files (PTUR) were utilized only to remove the most primary filling material (control groups). In the other groups (PTUR) used, it was first followed by supplementary files. The quantity of debris extruded by different retreatment file systems was determined and compared to the corresponding control group with or without apical patency. Data were analyzed using a two-way ANOVA with a post hoc Tukey's multiple comparison test at a 5% significance level. Results There was a statistically significant difference among the control and experimental groups. XPFR had the least quantity of extruded debris. Apical patency did not affect the debris extrusion. Conclusion All tested files led to a significant apical debris extrusion regardless of apical patency.
Collapse
|
13
|
Roshdy NN, Hassan R. Quantitative evaluation of apically extruded debris using TRUShape, TruNatomy, and WaveOne Gold in curved canals. BDJ Open 2022; 8:13. [PMID: 35595771 PMCID: PMC9122899 DOI: 10.1038/s41405-022-00106-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 02/19/2022] [Accepted: 02/21/2022] [Indexed: 11/09/2022] Open
Abstract
Abstract
Objective
This study compared the quantity of extruded debris after instrumentation with TRUShape 3D Conforming files, TruNatomy files, and the WaveOne Gold reciprocating system.
Materials and methods
Fifty-one mesiobuccal canals with severe curvatures (25–40°) were assigned to three equal groups according to the rotary system used for preparation, either TRUShape, TruNatomy, or WaveOne Gold files. The extruded debris was collected in pre-weighed glass vials. The data were statistically analyzed using a one-way ANOVA test and Tukey’s post hoc test.
Results
The least extruded debris was obtained with the WaveOne Gold instruments compared to the TRUShape and TruNatomy files (p < 0.001).
Conclusions
Debris extrusion occurs independently of the motion or design of the instrument. The WaveOne Gold system outperformed TRUShape and TruNatomy files in this study.
Collapse
|
14
|
Unno H, Ebihara A, Hirano K, Kasuga Y, Omori S, Nakatsukasa T, Kimura S, Maki K, Okiji T. Mechanical Properties and Root Canal Shaping Ability of a Nickel-Titanium Rotary System for Minimally Invasive Endodontic Treatment: A Comparative In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7929. [PMID: 36431416 PMCID: PMC9692467 DOI: 10.3390/ma15227929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 11/02/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
Selection of an appropriate nickel−titanium (NiTi) rotary system is important for minimally invasive endodontic treatment, which aims to preserve as much root canal dentin as possible. This study aimed to evaluate selected mechanical properties and the root canal shaping ability of TruNatomy (TRN), a NiTi rotary system designed for minimally invasive endodontic shaping, in comparison with existing instruments: HyFlex EDM (HEDM), ProTaper Next (PTN), and WaveOne Gold (WOG). Load values measured with a cantilever bending test were ranked as TRN < HEDM < WOG < PTN (p < 0.05). A dynamic cyclic fatigue test revealed that the number of cycles to fracture was ranked as HEDM > WOG > TRN > PTN (p < 0.05). Torque and vertical force generated during instrumentation of J-shaped artificial resin canals were measured using an automated instrumentation device connected to a torque and vertical force measuring system; TRN exhibited smaller torque and vertical force values in most comparisons with the other instruments. The canal centering ratio for TRN was smaller than or comparable to that for the other instruments except for WOG at the apex level. Under the present experimental conditions, TRN showed higher flexibility and lower torque and vertical force values than the other instruments.
Collapse
|
15
|
Silva EJNL, de Lima CO, Barbosa AFA, Lopes RT, Sassone LM, Versiani MA. The impact of TruNatomy and ProTaper Gold instruments on the preservation of the periradicular dentin and on the enlargement of the apical canal of mandibular molars. J Endod 2022; 48:650-658. [PMID: 35181453 DOI: 10.1016/j.joen.2022.02.003] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 01/25/2022] [Accepted: 02/07/2022] [Indexed: 02/08/2023]
Abstract
INTRODUCTION This study aimed to evaluate the preservation of the periradicular dentin and the enlargement of the apical canal of mandibular molars with TruNatomy and ProTaper Gold instruments. METHODS Twenty mandibular molars were scanned in a micro-CT device, anatomically paired, and distributed into 2 groups (n=10). In the ProTaper Gold group, mesial and distal canals were prepared up to F2 (25/.08v) and F3 (30/.09v) instruments, while in the TruNatomy group, mesial and distal canals were enlarged until Prime (26/.04v) and Medium (36/.03v) instruments, respectively. After a new scan, surface area, volume, unprepared areas, transportation, percentage of dentin removal, and dentin thickness parameters were calculated. Data were compared between groups using Mann-Whitney, Student t-test, and the non-metric multidimensional scaling test with alpha set at 5%. RESULTS No difference was found between groups regarding unprepared canal areas and reduction of dentin thickness (P > 0.05). Transportation was lower than 0.1 mm in all groups and statistical differences were observed only at the apical third of the mesiobuccal canal with lower values in the TruNatomy group. ProTaper Gold removed more dentin than TruNatomy at the coronal level of mesial roots (1.8% and 1.0%, respectively) (P < 0.05). CONCLUSIONS TruNatomy and ProTaper Gold were efficient for performing canal preparation in mandibular molars. The tested systems were similar in terms of untouched canal walls and remaining dentin thickness, and slightly different in the apical transportation of mesial canals and percentage of dentin removal at the coronal third, but without clinically significant errors.
Collapse
Affiliation(s)
- Emmanuel J N L Silva
- Departament of Endodontics, State University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
| | | | | | - Ricardo Tadeu Lopes
- Nuclear Engineering Program, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Luciana Moura Sassone
- Departament of Endodontics, State University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | | |
Collapse
|
16
|
Tanalp J. A critical analysis of research methods and experimental models to study apical extrusion of debris and irrigants. Int Endod J 2022; 55 Suppl 1:153-177. [DOI: 10.1111/iej.13686] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 01/14/2022] [Accepted: 01/18/2022] [Indexed: 11/30/2022]
Affiliation(s)
- J Tanalp
- Yeditepe University Faculty of Dentistry Department of Endodontics Istanbul Turkey
| |
Collapse
|
17
|
Varghese E, Venkatesh K. Comparative evaluation of cutting efficiency, cyclic fatigue, corrosion resistance, and autoclave cycle effects of three different file systems: An in-vitro micro-CT and metallurgy analysis. J Int Oral Health 2022. [DOI: 10.4103/jioh.jioh_91_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
|
18
|
Lee YJ, Kim S, Shin SJ. Volume Percentage of Filling Voids in Root Canals Prepared by a Novel Nickel-Titanium Rotary System (TruNatomy) Using Two Different Obturation Techniques. MATERIALS 2021; 14:ma14143846. [PMID: 34300765 PMCID: PMC8305233 DOI: 10.3390/ma14143846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Revised: 07/04/2021] [Accepted: 07/06/2021] [Indexed: 11/16/2022]
Abstract
This study aimed to compare the volume percentage of filling voids in root canals prepared with a newly introduced rotary system, TruNatomy (Dentsply Maillefer), and obturated by the modified continuous wave (CW) or single cone (SC) filling technique. Plastic tooth models with four canals were enlarged by using TruNatomy files and randomly allocated into either the CW or SC group. The volume percentage of filling voids at 1–6 mm from the apex was analyzed by using microcomputed tomography; mean values were compared by using independent two-sample t-tests (p < 0.05). The mean volume percentages of the filling voids were 2.81 ± 1.11% and 1.77 ± 0.82% in the CW and SC groups, respectively. In the apical area (1–4 mm), volume percentages in the palatal were significantly different between the CW and SC groups; in the middle area (4–6 mm), volume percentages in the palatal and the second mesiobuccal canals were significantly different (p < 0.05). The SC group showed lower volume percentages of filling voids than the CW group. The canals prepared by the TruNatomy system can be obturated well by both the SC and CW techniques. The SC technique showed a lower number of voids, especially in the palatal canals.
Collapse
Affiliation(s)
- You Jin Lee
- Gangnam Severance Hospital, Department of Conservative Dentistry, Yonsei University College of Dentistry, 211 Eonjuro, Gangnam-gu, Seoul 06273, Korea;
| | - Sunil Kim
- Department of Conservative Dentistry and Oral Science Research Center, Yonsei University College of Dentistry, 50-1 Yonsei-Ro, Seodaemun-gu, Seoul 03722, Korea;
| | - Su-Jung Shin
- Gangnam Severance Hospital, Department of Conservative Dentistry and Oral Science Research Center, Yonsei University College of Dentistry, 211 Eonjuro, Gangnam-gu, Seoul 06273, Korea
- Correspondence: ; Tel.: +82-2-2019-3572; Fax: +82-2-3463-4052
| |
Collapse
|
19
|
Al Omari T, El-Farraj H, Arıcan B, Atav Ateş A. Apical debris extrusion of full-sequenced rotary systems in narrow ribbon-shaped canals. AUST ENDOD J 2021; 48:245-250. [PMID: 34125465 DOI: 10.1111/aej.12540] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/24/2021] [Accepted: 05/26/2021] [Indexed: 02/05/2023]
Abstract
The apically extruded debris caused by TruNatomy System (TRN), RACE EVO system (RE) and VDW Rotate (VR) systems in mandibular anterior teeth with ribbon-shaped root canals were compared. The root canals (n = 20 in each group) were irrigated with NaOCl 2.5%, and the extruded debris was collected at pre-weighted Eppendorf tubes. The amount of apically extruded debris (mg) and the treatment time (s) were recorded. Tukey pairwise comparisons were performed to compare groups with a 95% confidence level. VR had significantly less debris extrusion values and treatment time than RE and TRN (P < 0.05). Although no difference was observed between RE and TRN in terms of apically extruded debris (P > 0.05), a significant difference in favour of RE was observed in terms of treatment time (P < 0.05). All the instruments extruded debris at varying weights.
Collapse
Affiliation(s)
- Taher Al Omari
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Hamza El-Farraj
- Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Burçin Arıcan
- Department of Endodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkey
| | - Ayfer Atav Ateş
- Department of Endodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkey
| |
Collapse
|