Li R, Zhu J, Wang S, Li X, Li S. Effects of sterilization and disinfection methods on digitally designed surgical implant guide accuracy: An in vitro study. Clin Implant Dent Relat Res 2024. [PMID: 38808751 DOI: 10.1111/cid.13350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 04/10/2024] [Accepted: 05/16/2024] [Indexed: 05/30/2024]
Abstract
INTRODUCTION Surgical guides are commonly used to assist with dental implant placement. This study investigated the effects of five sterilization and disinfection methods on the accuracy of implant guides. METHODS Thirty surgical guides (five in each group) were designed and printed (with digital light processing technology) using different sterilization or disinfection methods categorized into six groups: hydrogen peroxide sterilization (group one); glutaraldehyde sterilization (group two); autoclaving (group three); plasma sterilization (group four); iodophor disinfection (group five); and blank group (group six). Verification was determined using three methods: distance and angle between the cross-shaped marks, deformation after superimposing the guides, and displacement and axial changes in the virtual implant. RESULTS After disinfection and sterilization, the guides in the autoclaving and iodophor groups showed a more pronounced color change and the guide in the autoclaving group had visible cracks. More significant changes were observed in the H2O2, glutaraldehyde, autoclaving, and iodophor groups regarding deformation after superimposing the guides and the distance and angle between the cross-shaped marks. The average labial deformation values (mm) of the first through fifth groups of guides were 0.283, 0.172, 0.289, 0.153, and 0.188, respectively. All groups were statistically different from the blank group for displacement and axial changes of the virtual implant (p < 0.05). CONCLUSION The sizes of almost all surgical guides changed after sterilization and disinfection treatments, with between-group differences. Plasma sterilization was more suitable for surgical guide sterilization because of the smaller deformations after treatment.
Collapse
Affiliation(s)
- Ruikun Li
- Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, China
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jie Zhu
- Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, China
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Shuo Wang
- Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, China
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Xueyuan Li
- Department of Ophthalmology, the General Hospital of Western Theater Command, Chengdu, China
| | - Songhang Li
- Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, China
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| |
Collapse
|
2
|
Pop SI, Dudescu M, Mihali SG, Păcurar M, Bratu DC. Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement. Polymers (Basel) 2022; 14:polym14102107. [PMID: 35631989 PMCID: PMC9144921 DOI: 10.3390/polym14102107] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/18/2022] [Accepted: 05/19/2022] [Indexed: 02/01/2023] Open
Abstract
Three-dimensional printed surgical guides increase the precision of orthodontic mini-implant placement. The purpose of this research was to investigate the effects of disinfection and of two types of autoclave sterilization on the mechanical properties of 3D printed surgical guides obtained via the SLA (stereolithography) and DLP (digital light processing) printing methods. A total of 96 standard specimens (48 SLA and 48 DLP) were printed to analyze the tensile and flexural properties of the materials. A total of 80 surgical guide (40 SLA and 40 DLP) specimens from each printing method were classified into four groups: CG (control group); G1, disinfected with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany); G2, autoclave-sterilized (121 °C); and G3, autoclave-sterilized (134 °C). Significant differences in the maximum compressive load were determined between the groups comprising the DLP-(p < 0.001) and the SLA- (p < 0.001) printed surgical guides. Groups G2 (p = 0.001) and G3 (p = 0.029) showed significant parameter modifications compared with the CG. Disinfection with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany) is suitable both for SLA- and DLP-printed surgical guides. Heat sterilization at both 121 °C and 134 °C modified the mechanical properties of the surgical guides.
Collapse
Affiliation(s)
- Silvia Izabella Pop
- Orthodontic Department, Faculty of Dental Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 38 Gh. Marinescu Str., 540139 Târgu Mureș, Romania; (S.I.P.); (M.P.)
| | - Mircea Dudescu
- Department of Mechanical Engineering, Technical University of Cluj-Napoca, 28 Memorandumului Street, 400114 Cluj-Napoca, Romania
- Correspondence: (M.D.); (S.G.M.)
| | - Sorin Gheorghe Mihali
- Department of Prosthodontics, Faculty of Dentistry, “Vasile Goldis” Western University of Arad, 94 Revolutiei Blvd, 310025 Arad, Romania
- Correspondence: (M.D.); (S.G.M.)
| | - Mariana Păcurar
- Orthodontic Department, Faculty of Dental Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 38 Gh. Marinescu Str., 540139 Târgu Mureș, Romania; (S.I.P.); (M.P.)
| | - Dana Cristina Bratu
- Department of Orthodontics and Dento-Facial Orthopedics, Orthodontic Research Center, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy, 2 Eftimie Murgu Square, 300041 Timișoara, Romania;
| |
Collapse
|
3
|
Biedrzycki AH, Kistler HC, Perez-Jimenez EE, Morton AJ. Use of Hausdorff Distance and Computer Modelling to Evaluate Virtual Surgical Plans with Three-Dimensional Printed Guides against Freehand Techniques for Navicular Bone Repair in Equine Orthopaedics. Vet Comp Orthop Traumatol 2021; 34:9-16. [PMID: 33440435 DOI: 10.1055/s-0040-1721846] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the surgical execution of a virtual surgical plan (VSP) with three-dimensional (3D) guides against a freehand approach in the equine navicular bone using an automated in silico computer analysis technique. STUDY DESIGN Eight pairs of cadaveric forelimb specimens of adult horses were used in an ex vivo experimental study design with in silico modelling. Limbs received either a 3.5 mm cortical screw according to a VSP or using an aiming device. Using computed tomography and computer segmentation, a comparison was made between the executed screw and the planned screw using the Hausdorff distance (HD). RESULTS Navicular bone mean HD registration error was -0.06 ± 0.29 mm. The VSP with 3D printing demonstrated significantly superior accuracy with a mean deviation of 1.19 ± 0.42 mm compared with aiming device group (3.53 ± 1.24 mm, p = 0.0018). The VSP group was 5.0 times more likely to result in a mean aberration of less than 1.0 mm (95% confidence interval, 0.62-33.4). A 3.5 mm screw with an optimal entry point can have a maximum deviation angle of 3.23 ± 0.07, 2.70 ± 0.06 and 2.37 ± 0.10 degrees in a proximal, dorsal and palmar direction respectively, prior to violating one of the cortical surfaces. CONCLUSION Procedures performed using the 3D guides have a high degree of accuracy, with minimal mean deviations (<1 mm and <1 degree) of a VSP compared with those using the conventional aiming device. The use of VSP and the HD for evaluation of orthopaedic surgeries and outcome measures shows promise for simplifying and improving surgical accuracy.
Collapse
Affiliation(s)
- Adam H Biedrzycki
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, United States
| | - Hannah C Kistler
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, United States
| | | | - Alison J Morton
- Department of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, United States
| |
Collapse
|
4
|
Török G, Gombocz P, Bognár E, Nagy P, Dinya E, Kispélyi B, Hermann P. Effects of disinfection and sterilization on the dimensional changes and mechanical properties of 3D printed surgical guides for implant therapy - pilot study. BMC Oral Health 2020; 20:19. [PMID: 31973705 PMCID: PMC6979289 DOI: 10.1186/s12903-020-1005-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Accepted: 01/13/2020] [Indexed: 11/26/2022] Open
Abstract
Background The purpose of this research was to investigate the effects of disinfection and three different sterilization methods on the dimensional changes and mechanical properties of three-dimensional (3D) printed surgical guide for implant therapy. The objective was to assess the effects of sterilization procedures in 3D printed drill guide templates with destructive and non-destructive material testing. Methods Fifteen identical drill guide templates were produced using a 3D printer. The surgical guides were classified into five groups: three controls, three disinfected (4% Gigasept®, 60 min), three plasma sterilized, three autoclave sterilized (+ 1 bar, 121 °C, 20 min), and three autoclave sterilized (+ 2 bar, 134 °C, 10 min). The templates were digitalized with a Steinbichler SCAN ST 3D scanner. Length was measured under an SZX16 stereomicroscope. A scanning electron microscope was used to study the surface morphology of the drill templates. The hardness, and flexural and compressive strength were measured to assess any changes in the physical characteristics of the material caused by sterilization. The drill guide templates were also examined with a Dage XiDAT 6600 X-ray. During the X-ray examinations, the following parameters were used: 100 kV voltage, 128 AVG averaging, 0.8 W power. One-way analysis of variance (ANOVA) was used to detect the difference between groups. Results Evaluation of the hardness measurements of the various specimens shows that the hardness of the material was not changed by the plasma sterilization (p = 0.0680), steam sterilization on 121 °C (p = 0.6033) or disinfection process (p = 0.1399). The statistical analysis revealed significant difference in hardness strength of the autoclave sterilized (134 °C) specimens (p = 0.0002). There was no significant difference between the goups regarding the scanning electron microscopic and stereomicroscopic examinations. There was no significant difference regarding the X-ray visibility of the templates to the effect of the disinfection (p = 0.7844), plasma sterilization (p = 0.4091) and steam sterilization on 121 °C (p = 0.9277) and steam sterilization on 131 °C (p = 0.093). The effect of the sterilization was the same in case of both flexural and compressive strength of the material. Conclusions Our findings indicate that plasma sterilization and steam sterilization at 121 °C were both suitable for sterilizing the tested 3D printed surgical guides.
Collapse
Affiliation(s)
- Gréta Török
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi Street 47, Budapest, H-1088, Hungary.
| | - Péter Gombocz
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi Street 47, Budapest, H-1088, Hungary
| | - Eszter Bognár
- Department of Materials Science and Engineering, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Bertalan Lajos Street 7, Budapest, H-1111, Hungary.,Budapest and MTA-BME Research Group for Composite Science and Technology, Műegyetem rkp. 3, Budapest, H-1111, Hungary
| | - Péter Nagy
- Department of Materials Science and Engineering, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Bertalan Lajos Street 7, Budapest, H-1111, Hungary
| | - Elek Dinya
- Institute of Digital Health Sciences, Semmelweis University, Ferenc Square 15., Budapest, H-1094, Hungary
| | - Barbara Kispélyi
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi Street 47, Budapest, H-1088, Hungary
| | - Péter Hermann
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi Street 47, Budapest, H-1088, Hungary
| |
Collapse
|
5
|
Soft Tissue Changes in Patients Undergoing Intraoral Quadrangular Le Fort II Osteotomy Versus Conventional Le Fort I Osteotomy. J Oral Maxillofac Surg 2018; 76:416-425. [DOI: 10.1016/j.joms.2017.07.158] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 06/12/2017] [Accepted: 07/11/2017] [Indexed: 11/21/2022]
|