1
|
Schimek A, Ng JK, Basbas I, Martin F, Xin D, Saleh D, Hubbuch J. An HPLC-SEC-based rapid quantification method for vesicular stomatitis virus particles to facilitate process development. Mol Ther Methods Clin Dev 2024; 32:101252. [PMID: 38774583 PMCID: PMC11107205 DOI: 10.1016/j.omtm.2024.101252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Accepted: 04/18/2024] [Indexed: 05/24/2024]
Abstract
Virus particle (VP) quantification plays a pivotal role in the development of production processes of VPs for virus-based therapies. The yield based on total VP count serves as a process performance indicator for evaluating process efficiency and consistency. Here, a label-free particle quantification method for enveloped VPs was developed, with potential applications in oncolytic virotherapy, vaccine development, and gene therapy. The method comprises size-exclusion chromatography (SEC) separation using high-performance liquid chromatography (HPLC) instruments. Ultraviolet (UV) was used for particle quantification and multi-angle light scattering (MALS) for particle characterization. Consistent recoveries of over 97% in the SEC were achieved upon mobile phase screenings and addition of bovine serum albumin (BSA) as sample stabilizer. A calibration curve was generated, and the method's performance and applicability to in-process samples were characterized. The assay's repeatability variation was <1% and its intermediate precision variation was <3%. The linear range of the method spans from 7.08 × 108 to 1.72 × 1011 VP/mL, with a limit of detection (LOD) of 7.72 × 107 VP/mL and a lower limit of quantification (LLOQ) of 4.20 × 108 VP/mL. The method, characterized by its high precision, requires minimal hands-on time and provides same-day results, making it efficient for process development.
Collapse
Affiliation(s)
- Adrian Schimek
- ViraTherapeutics GmbH, Bundesstraße 27, 6063 Rum, Austria
| | - Judy K.M. Ng
- ViraTherapeutics GmbH, Bundesstraße 27, 6063 Rum, Austria
| | - Ioannes Basbas
- ViraTherapeutics GmbH, Bundesstraße 27, 6063 Rum, Austria
| | - Fabian Martin
- ViraTherapeutics GmbH, Bundesstraße 27, 6063 Rum, Austria
| | - Dongyue Xin
- Boehringer Ingelheim Pharmaceuticals Inc, 900 Ridgebury Road, Ridgefield, CT 06877, USA
| | - David Saleh
- Boehringer Ingelheim Pharma GmbH & Co. KG, Birkendorfer Str. 65, 88397 Biberach, Germany
| | - Jürgen Hubbuch
- Karlsruhe Institute of Technology, Institute of Process Engineering in Life Sciences, Section IV Biomolecular Separation Engineering, Fritz-Haber-Weg 2, 76131 Karlsruhe, Germany
| |
Collapse
|
2
|
James KT, Cooney B, Agopsowicz K, Trevors MA, Mohamed A, Stoltz D, Hitt M, Shmulevitz M. Novel High-throughput Approach for Purification of Infectious Virions. Sci Rep 2016; 6:36826. [PMID: 27827454 PMCID: PMC5101806 DOI: 10.1038/srep36826] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2016] [Accepted: 10/21/2016] [Indexed: 01/02/2023] Open
Abstract
Viruses are extensively studied as pathogens and exploited as molecular tools and therapeutic agents. Existing methods to purify viruses such as gradient ultracentrifugation or chromatography have limitations, for example demand for technical expertise or specialized equipment, high time consumption, and restricted capacity. Our laboratory explores mutations in oncolytic reovirus that could improve oncolytic activity, and makes routine use of numerous virus variants, genome reassortants, and reverse engineered mutants. Our research pace was limited by the lack of high-throughput virus purification methods that efficiently remove confounding cellular contaminants such as cytokines and proteases. To overcome this shortcoming, we evaluated a commercially available resin (Capto Core 700) that captures molecules smaller than 700 kDa. Capto. Core 700 chromatography produced virion purity and infectivity indistinguishable from CsCl density gradient ultracentrifugation as determined by electron microscopy, gel electrophoresis analysis and plaque titration. Capto Core 700 resin was then effectively adapted to a rapid in-slurry pull-out approach for high-throughput purification of reovirus and adenovirus. The in-slurry purification approach offered substantially increased virus purity over crude cell lysates, media, or high-spin preparations and would be especially useful for high-throughput virus screening applications where density gradient ultracentrifugation is not feasible.
Collapse
Affiliation(s)
- Kevin T James
- Department of Medical Microbiology and Immunology, Li Ka Shing Institute of Virology, University of Alberta, Edmonton, Alberta, Canada
| | - Brad Cooney
- GE Healthcare, LifeSciences, Marlborough, MA, US
| | - Kate Agopsowicz
- Department of Oncology, University of Alberta, Edmonton, Alberta, Canada
| | - Mary Ann Trevors
- Department of Microbiology and Immunology, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Adil Mohamed
- Department of Medical Microbiology and Immunology, Li Ka Shing Institute of Virology, University of Alberta, Edmonton, Alberta, Canada
| | - Don Stoltz
- Department of Microbiology and Immunology, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Mary Hitt
- Department of Oncology, University of Alberta, Edmonton, Alberta, Canada
| | - Maya Shmulevitz
- Department of Medical Microbiology and Immunology, Li Ka Shing Institute of Virology, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
3
|
Kramberger P, Urbas L, Štrancar A. Downstream processing and chromatography based analytical methods for production of vaccines, gene therapy vectors, and bacteriophages. Hum Vaccin Immunother 2015; 11:1010-21. [PMID: 25751122 PMCID: PMC4514237 DOI: 10.1080/21645515.2015.1009817] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2014] [Accepted: 12/25/2014] [Indexed: 10/23/2022] Open
Abstract
Downstream processing of nanoplexes (viruses, virus-like particles, bacteriophages) is characterized by complexity of the starting material, number of purification methods to choose from, regulations that are setting the frame for the final product and analytical methods for upstream and downstream monitoring. This review gives an overview on the nanoplex downstream challenges and chromatography based analytical methods for efficient monitoring of the nanoplex production.
Collapse
|
4
|
Transfiguracion J, Manceur AP, Petiot E, Thompson CM, Kamen AA. Particle quantification of influenza viruses by high performance liquid chromatography. Vaccine 2015; 33:78-84. [DOI: 10.1016/j.vaccine.2014.11.027] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2014] [Revised: 11/08/2014] [Accepted: 11/15/2014] [Indexed: 01/02/2023]
|
5
|
Development and validation of a HPLC method for the quantification of baculovirus particles. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:61-8. [DOI: 10.1016/j.jchromb.2010.11.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2010] [Revised: 11/05/2010] [Accepted: 11/08/2010] [Indexed: 02/05/2023]
|
6
|
Transfiguracion J, Bernier A, Voyer R, Coelho H, Coffey M, Kamen A. Rapid and reliable quantification of reovirus type 3 by high performance liquid chromatography during manufacturing of Reolysin. J Pharm Biomed Anal 2008; 48:598-605. [PMID: 18632239 DOI: 10.1016/j.jpba.2008.05.038] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2008] [Revised: 05/23/2008] [Accepted: 05/27/2008] [Indexed: 11/25/2022]
Abstract
Reolysin, a human reovirus type 3, is being evaluated in the clinic as an oncolytic therapy for various types of cancer. To facilitate the optimization and scale-up of the current process, a high performance liquid chromatography (HPLC) method has been developed that is rapid, specific and reliable for the quantification of reovirus type 3 particles. Using an anion-exchange column, the intact virus eluted from the contaminants in 9.78 min at 350 mM NaCl in 50mM HEPES, pH 7.10 in a total analysis time of 25 min. The virus demonstrated a homogenous peak with no co-elution of other compounds as analyzed by photodiode array analysis. The HPLC method facilitated the optimization of the purification process which resulted in the improvement of both total and infectious particle recovery and contributed to the successful scale-up of the process at the 20 L, 40 L and 100 L production scale. The method is suitable for the analysis of crude virus supernatants, crude lysates, semi-purified and purified preparations and therefore is an ideal monitoring tool during process development and scale-up.
Collapse
Affiliation(s)
- Julia Transfiguracion
- Animal Cell Technology Group, Bioprocess Sector, Biotechnology Research Institute, National Research Council Canada, 6100 Royalmount Avenue, Montreal, Quebec, Canada H4P 2R2
| | | | | | | | | | | |
Collapse
|