1
|
Kilianova Z, Cizmarova I, Spaglova M, Piestansky J. Recent Trends in Therapeutic Drug Monitoring of Peptide Antibiotics. J Sep Sci 2024; 47:e202400583. [PMID: 39400453 DOI: 10.1002/jssc.202400583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2024] [Revised: 09/17/2024] [Accepted: 09/19/2024] [Indexed: 10/15/2024]
Abstract
Antimicrobial peptides take a specific position in the field of antibiotics (ATBs), however, from a large number of available molecules only a few of them were approved and are used in clinics. These therapeutic modalities play a crucial role in the management of diseases caused by multidrug-resistant bacterial pathogens and represent the last-line therapy for bacterial infections. Therefore, there is a demand for a rationale use of such ATBs based on optimization of the dosing strategy to minimize the risk of resistance and ensure the sustainable efficacy of the drug in real clinical practice. Therapeutic drug monitoring, as a measurement of drug concentration in the body fluids or tissues, results in the optimization of the patient´s medication and therapy outcome. This strategy is beneficial and could result in tailored therapy for different types of infection and the prolongation of the use and efficacy of ATBs in hospitals. This review paper provides an actual overview of approved antimicrobial peptides used in clinical practice and covers current trends in their analysis by convenient and advanced methodologies used for their identification and/or quantitation in biological matrices for therapeutic drug monitoring purposes. Special emphasis is given to the methods with perspective clinical outcomes.
Collapse
Affiliation(s)
- Zuzana Kilianova
- Department of Pharmacology and Toxicology, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovak Republic
| | - Ivana Cizmarova
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovak Republic
| | - Miroslava Spaglova
- Department of Galenic Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovak Republic
| | - Juraj Piestansky
- Department of Galenic Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovak Republic
- Toxicological and Antidoping Center, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovak Republic
- Institute of Neuroimmunology, Slovak Academy of Sciences, Bratislava, Slovak Republic
| |
Collapse
|
2
|
Nakhonchai N, Prompila N, Ponhong K, Siriangkhawut W, Vichapong J, Supharoek SA. Green hairy basil seed mucilage biosorbent for dispersive solid phase extraction enrichment of tetracyclines in bovine milk samples followed by HPLC analysis. Talanta 2024; 271:125645. [PMID: 38219323 DOI: 10.1016/j.talanta.2024.125645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 01/02/2024] [Accepted: 01/06/2024] [Indexed: 01/16/2024]
Abstract
Unmodified hairy basil seed mucilage (Ocimum basilicum L.), with attractive features as structural functionality and adsorption capacity, was employed as a green biosorbent for dispersive solid phase extraction and enrichment of oxytetracycline, tetracycline, and doxycycline before quantitation by HPLC-UV for the first time. Hairy basil crushed seed increased the contacting surface area and was completely dispersed in the sample solution to extract tetracyclines under acidic condition with the assistance of ultrasonic waves. The analytes in the extraction phase were separated on a C18 column under isocratic condition with a mobile phase consisted of acetonitrile and trifluoroacetic acid. Influence of chemical and physical variables on the extraction efficiency of the developed method was investigated and optimized systematically. Under the optimal condition of all experimental parameters, good linear ranges were obtained at 15.0-500 μg L-1 for tetracyclines with determination coefficients more than 0.9994. Limits of detection (LODs) and limits of quantitation (LOQs) ranged 5.0-7.0 and 15.0 μg L-1, respectively. Relative standard deviations (RSDs) of the proposed method at 100 and 300 μg L-1 for TCs were less than 13 % and 10 %, respectively with percentage TC recoveries from spiked standard ranging 83.1-109.9 %. This simple, reliable, cost-effective, and environmentally friendly method was successfully applied for the analysis of tetracycline residues in milk. The greenness of the proposed method was assessed using the Analytical Eco-Scale and AGREE protocol.
Collapse
Affiliation(s)
- Nongnapas Nakhonchai
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University, Maha Sarakham, 44150, Thailand
| | - Nattaya Prompila
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University, Maha Sarakham, 44150, Thailand
| | - Kraingkrai Ponhong
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University, Maha Sarakham, 44150, Thailand; Multidisciplinary Research Unit of Pure and Applied Chemistry, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University, Maha Sarakham, 44150, Thailand
| | - Watsaka Siriangkhawut
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University, Maha Sarakham, 44150, Thailand
| | - Jitlada Vichapong
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University, Maha Sarakham, 44150, Thailand; Multidisciplinary Research Unit of Pure and Applied Chemistry, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University, Maha Sarakham, 44150, Thailand
| | - Sam-Ang Supharoek
- Department of Medical Science, Amnatcharoen Campus, Mahidol University, Amnat Charoen, 3700, Thailand; Department of Chemistry and Center for Innovation in Chemistry, Faculty of Science, Mahidol University, Bangkok, 10400, Thailand.
| |
Collapse
|
3
|
Hu B. Non-invasive Sampling of Human Body Fluids Using In Vivo SPME. EVOLUTION OF SOLID PHASE MICROEXTRACTION TECHNOLOGY 2023:451-465. [DOI: 10.1039/bk9781839167300-00451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Noninvasive body fluids offer attractive sources to gain insights into human health. The in vivo solid-phase microextraction (SPME) technique is a fast and versatile sample preparation technique for the noninvasive sampling of human body fluids in various fields. This chapter summarizes the applications of SPME coupled with mass spectrometry (MS)-based approaches for noninvasive investigations of human body fluids, including urine, sweat, and saliva. New features of noninvasive SPME sampling and MS-based analysis are highlighted, and the prospects on their further development are also discussed.
Collapse
Affiliation(s)
- Bin Hu
- Institute of Mass Spectrometry and Atmospheric Environment Jinan University Guangzhou 510632 China
| |
Collapse
|
4
|
Costa Queiroz ME, Donizeti de Souza I, Gustavo de Oliveira I, Grecco CF. In vivo solid phase microextraction for bioanalysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116656] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
5
|
Adsorption characteristics of polythiophene for tetracyclines and determination of tetracyclines in fish and chicken manure by solid phase extraction-HPLC method. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106935] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
6
|
Meng L, Dai Y, Chen C, Zhang J. Determination of amphetamines, ketamine and their metabolites in hair with high-speed grinding and solid-phase microextraction followed by LC-MS. Forensic Sci Res 2021; 6:273-280. [PMID: 34868720 PMCID: PMC8635643 DOI: 10.1080/20961790.2020.1838403] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
A novel hair sample pre-treatment method based on high-speed grinding and solid-phase microextraction (SPME) had been applied for the determination of amphetamines, ketamine and their metabolites in hair samples by liquid chromatography-mass spectrometry (LC-MS). A 20 mg sample of hair was ground with 2 mL of saturated sodium carbonate solution using a high-efficiency hair grinder with 70 Hz oscillation for 2 min at 4 °C. After centrifuging, 1.5 mL of the supernatant was transferred and treated with SPME by direct immersion (DI-SPME). The target analytes extracted by fibre were desorbed and analysed using LC-MS. Under the optimum conditions, a recovery of 90.2%–95.8% was obtained for all analytes. The analytical method was linear for all analytes in the range from 0.2 to 10 ng/mg with the correlation coefficient ranging from 0.9985 to 0.9993. The detection limits for all analytes were estimated to be 0.067 ng/mg. The accuracy (mean relative error) was within ±6.9% and the precision (relative standard error) was less than 6.8%. The combination of high-speed grinding of hair and SPME had the advantages of being easy to perform, environment-friendly and high in detection sensitivity. The proposed method offered an alternative analytical approach for the sensitive detection of drugs in hair samples for forensic purposes.Key Points The SPME was involved for the determination of drugs in hair with LC-MS. The hair high-speed grinding combined with SPME was firstly developed. Good linearity, sensitivity, recovery and precision were achieved.
Collapse
Affiliation(s)
- Liang Meng
- Department of Forensic Science, Fujian Police College, Fuzhou, China.,Engineering Research Center, Fujian Police College, Fuzhou, China
| | - Yong Dai
- Department of Forensic Science, Sichuan Police College, Luzhou, China
| | - Chen Chen
- Drug Research Center of Integrated Traditional Chinese and Western Medicine, Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, China
| | - Jun Zhang
- Department of Forensic Science, Fujian Police College, Fuzhou, China
| |
Collapse
|
7
|
Khan AU, Shah F, Khan RA, Ismail B, Khan AM, Muhammad H. Preconcentration of rifampicin prior to its efficient spectroscopic determination in the wastewater samples based on a nonionic surfactant. Turk J Chem 2021; 45:1201-1209. [PMID: 34707444 PMCID: PMC8517608 DOI: 10.3906/kim-2102-28] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 05/10/2021] [Indexed: 11/22/2022] Open
Abstract
Every year, tuberculosis affects the lungs of millions of people and rifampicin is the commonly used medicine for its treatment due to its antibiotic nature. The frequent use of rifampicin may lead to its increased concentration in the water resources. This research work is focused on the cloud point extraction (CPE) procedure for the preconcentration of rifampicin prior to its determination in water. The UV/vis spectrophotometric method was adapted for the measurement of rifampicin content after the phase separation. Triton-X 100 was used as the nonionic surfactant which contains hydrophilic polyethylene chain feasible for the extraction of analyte. Various analytical parameters that can affect the extraction efficacy were optimized to achieve linearity of the proposed method in the concentration range of 3.54–81.41 mgL–1. The Limit of detection and quantification were 1.261 and 4.212 mgL–1, respectively. The Preconcentration factor was 40 with relative standard deviation (%RSD) of 2.504%. The standard addition methodology was adopted for the validation of this procedure and effectively applied for the determination of rifampicin in real wastewater samples.
Collapse
Affiliation(s)
- Afaq Ullah Khan
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Pakistan
| | - Faheem Shah
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Pakistan
| | - Rafaqat Ali Khan
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Pakistan
| | - Bushra Ismail
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Pakistan
| | - Asad Mohammad Khan
- Department of Chemistry, COMSATS University Islamabad, Abbottabad Pakistan
| | - Haji Muhammad
- Department of Chemistry, Federal Urdu University of Arts, Sciences and Technology, Karachi Pakistan
| |
Collapse
|
8
|
Hu B, Ouyang G. In situ solid phase microextraction sampling of analytes from living human objects for mass spectrometry analysis. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116368] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
9
|
Pelit L, Pelit F, Ertaş H, Ertaş FN. Electrochemically Fabricated Solid Phase Microextraction Fibers and Their Applications in Food, Environmental and Clinical Analysis. CURR ANAL CHEM 2019. [DOI: 10.2174/1573411015666190314155440] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Background:Designing an analytical methodology for complicated matrices, such as biological and environmental samples, is difficult since the sample preparation procedure is the most demanding step affecting the whole analytical process. Nowadays, this step has become more challenging by the legislations and environmental concerns since it is a prerequisite to eliminate or minimize the use of hazardous substances in traditional procedures by replacing with green techniques suitable for the sample matrix.Methods:In addition to the matrix, the nature of the analyte also influence the ease of creating green analytical techniques. Recent developments in the chemical analysis provide us new methodologies introducing microextraction techniques and among them, solid phase microextraction (SPME) has emerged as a simple, fast, low cost, reliable and portable sample preparation technique that minimizes solvent consumption.Results:The use of home-made fibers is popular in the last two decades since the selectivity can be tuned by changing the surface characteristics through chemical and electrochemical modifications. Latter technique is preferred since the electroactive polymers can be coated onto the fiber under controlled electrochemical conditions and the film thicknesses can be adjusted by simply changing the deposition parameters. Thermal resistance and mechanical strength can be readily increased by incorporating different dopant ions into the polymeric structure and selectivity can be tuned by inserting functional groups and nanostructures. A vast number of analytes with wide range of polarities extracted by this means can be determined with a suitable chromatographic detector coupled to the system. Therefore, the main task is to improve the physicochemical properties of the fiber along with the extraction efficiency and selectivity towards the various analytes by adjusting the electrochemical preparation conditions.Conclusion:This review covers the fine tuning conditions practiced in electrochemical preparation of SPME fibers and in-tube systems and their applications in environmental, food and clinical analysis.
Collapse
Affiliation(s)
- Levent Pelit
- Department of Chemistry, Science Faculty, Ege University, Bornova, 35 100, İzmir, Turkey
| | - Füsun Pelit
- Department of Chemistry, Science Faculty, Ege University, Bornova, 35 100, İzmir, Turkey
| | - Hasan Ertaş
- Department of Chemistry, Science Faculty, Ege University, Bornova, 35 100, İzmir, Turkey
| | - Fatma Nil Ertaş
- Department of Chemistry, Science Faculty, Ege University, Bornova, 35 100, İzmir, Turkey
| |
Collapse
|
10
|
Ma X, Huang P, Dang X, Ai Y, Zheng D, Chen H. MWCNTs/MnO2 nanocomposite-based polythiophene coating for solid-phase microextraction and determination of polycyclic aromatic hydrocarbons in soil. Microchem J 2019. [DOI: 10.1016/j.microc.2019.02.031] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
11
|
Dei Cas M, Casagni E, Gambaro V, Cesari E, Roda G. Determination of daptomycin in human plasma and breast milk by UPLC/MS-MS. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1116:38-43. [DOI: 10.1016/j.jchromb.2019.03.036] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 03/04/2019] [Accepted: 03/27/2019] [Indexed: 11/25/2022]
|
12
|
Fernandes GFDS, Salgado HRN, Santos JLD. A critical review of HPLC-based analytical methods for quantification of Linezolid. Crit Rev Anal Chem 2019; 50:196-211. [PMID: 31017000 DOI: 10.1080/10408347.2019.1605876] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Linezolid is a synthetic antimicrobial agent belonging to the oxazolidinone class. Since its approval in the year 2000 until now, linezolid remains the main representative drug for the oxazolidinone class of drugs, which is used in therapy due to its unique mode of action, which involves inhibition of protein synthesis. As linezolid holds great importance in antimicrobial therapy, it is necessary to compile the various analytical methods that have been reported in the literature for its analysis. Analytical techniques used for pharmaceutical analyses and therapeutic drug monitoring play an important role in comprehending the aspects regarding bioavailability, bioequivalence, and therapeutic monitoring during patient follow-ups. Even though linezolid has had the approval for clinical use for more than 18 years now, most of the analytical methods for its determination reported in the scientific literature are the ones which utilize HPLC. Therefore, the present review provides a summary of the HPLC-based methods used in the determination and quantification of linezolid in different matrices since the time of its discovery.
Collapse
Affiliation(s)
- Guilherme Felipe Dos Santos Fernandes
- Institute of Chemistry, São Paulo State University, Araraquara, Brazil.,School of Pharmaceutical Sciences, São Paulo State University, Araraquara, Brazil
| | | | - Jean Leandro Dos Santos
- Institute of Chemistry, São Paulo State University, Araraquara, Brazil.,School of Pharmaceutical Sciences, São Paulo State University, Araraquara, Brazil
| |
Collapse
|
13
|
Ghadi M, Hadjmohammadi MR. Extraction and determination of three benzodiazepines in aqueous and biological samples by air-assisted liquid–liquid microextraction and high-performance liquid chromatography. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2019. [DOI: 10.1007/s13738-018-01590-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
14
|
Lashgari M, Yamini Y. An overview of the most common lab-made coating materials in solid phase microextraction. Talanta 2019; 191:283-306. [DOI: 10.1016/j.talanta.2018.08.077] [Citation(s) in RCA: 75] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Revised: 08/24/2018] [Accepted: 08/27/2018] [Indexed: 11/28/2022]
|
15
|
Cheng X, Zhang C, Di Y, Li N, Yao H, Dong Y. An LC-MS/MS method for quantification of daptomycin in dried blood spot: Application to a pharmacokinetics study in critically ill patients. J LIQ CHROMATOGR R T 2018. [DOI: 10.1080/10826076.2018.1492935] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Xiaoliang Cheng
- Department of Pharmacy, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, China
| | - Chun Zhang
- Surgical Intensive Care Unit, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, China
| | - Ying Di
- Surgical Intensive Care Unit, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, China
| | - Na Li
- Surgical Intensive Care Unit, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, China
| | - Hongping Yao
- Department of Pharmacy, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, China
| | - Yalin Dong
- Department of Pharmacy, The First Affiliated Hospital of Xi’an Jiaotong University, Xi'an, China
| |
Collapse
|
16
|
Franco de Oliveira SCWSE, Zucoloto AD, de Oliveira CDR, Hernandez EMM, Fruchtengarten LVG, de Oliveira TF, Yonamine M. Development of a simple HPLC-DAD multi-analyte procedure and its application in cases evaluated by the Poison Control Center of São Paulo, Brazil. Biomed Chromatogr 2018; 32:e4360. [PMID: 30109709 DOI: 10.1002/bmc.4360] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 07/24/2018] [Accepted: 08/06/2018] [Indexed: 01/20/2023]
Abstract
This work describes a simple approach to overcome challenges in emergency toxicological analysis, using liquid-liquid extraction and high-performance liquid chromatography coupled with a diode-array detector (HPLC-DAD). A rapid procedure has been developed, for the extraction and detection of 19 analytes from the following drug classes: analgesics, benzodiazepines, antidepressants, anticonvulsants and drugs of abuse. These substances are relevant in the context of emergency toxicology in Brazil. The method has been validated according to international guidelines by establishing parameters such as lower limit of quantification, sensitivity, linearity, accuracy and precision. The intra and inter-day precision values, at the lowest concentration levels, have always been less than 20% considering its relative standard deviation. As for accuracy values, these have also been satisfactory (above 81.3%). This method was successfully applied in 201 blood samples from patients with suspected poisoning of the Poison Control Center of São Paulo (PCC-SP), Brazil. Finally, the developed method has shown to be relevant for emergency toxicology due to its high sensitivity and it could be also very useful in both fields of clinical and forensic toxicology.
Collapse
Affiliation(s)
| | - Alexandre D Zucoloto
- Faculty of Pharmaceutical Sciences, University of Sao Paulo, São Paulo, SP, Brazil.,Poison Control Center of Sao Paulo, SP, Brazil
| | | | | | | | - Tiago F de Oliveira
- Federal University of Health Sciences of Porto Alegre, Porto Alegre, RS, Brazil
| | - Mauricio Yonamine
- Faculty of Pharmaceutical Sciences, University of Sao Paulo, São Paulo, SP, Brazil
| |
Collapse
|
17
|
Jafari S, Hamidi S. Microextraction techniques in antibiotic monitoring in body fluids: Recent trends and future. J LIQ CHROMATOGR R T 2018. [DOI: 10.1080/10826076.2017.1399418] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Affiliation(s)
- Samira Jafari
- Department of Pharmaceutical Biomaterial, School of Pharmacy and Medical Biomaterials Research Center (MBRC), Tehran University of Medical Sciences, Tehran, Iran
| | - Samin Hamidi
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz, Iran
| |
Collapse
|
18
|
Clinical application of microsampling versus conventional sampling techniques in the quantitative bioanalysis of antibiotics: a systematic review. Bioanalysis 2018; 10:407-423. [DOI: 10.4155/bio-2017-0269] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Conventional sampling techniques for clinical pharmacokinetic studies often require the removal of large blood volumes from patients. This can result in a physiological or emotional burden, particularly for neonates or pediatric patients. Antibiotic pharmacokinetic studies are typically performed on healthy adults or general ward patients. These may not account for alterations to a patient’s pathophysiology and can lead to suboptimal treatment. Microsampling offers an important opportunity for clinical pharmacokinetic studies in vulnerable patient populations, where smaller sample volumes can be collected. This systematic review provides a description of currently available microsampling techniques and an overview of studies reporting the quantitation and validation of antibiotics using microsampling. A comparison of microsampling to conventional sampling in clinical studies is included.
Collapse
|
19
|
Machini WBS, Oliveira-Brett AM. Cyclic Lipopeptide Antibiotic Daptomycin Electrochemical Oxidation at a Glassy Carbon Electrode. ELECTROANAL 2017. [DOI: 10.1002/elan.201700037] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Wesley B. S. Machini
- Department of Chemistry; Faculty of Sciences and Technology, University of Coimbra; 3004-535 Coimbra Portugal
| | - A. M. Oliveira-Brett
- Department of Chemistry; Faculty of Sciences and Technology, University of Coimbra; 3004-535 Coimbra Portugal
| |
Collapse
|
20
|
Mohammed SA, Eissa MS, Ahmed HM. Simple protein precipitation extraction technique followed by validated chromatographic method for linezolid analysis in real human plasma samples to study its pharmacokinetics. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1043:235-240. [DOI: 10.1016/j.jchromb.2016.09.042] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Revised: 09/26/2016] [Accepted: 09/28/2016] [Indexed: 11/17/2022]
|
21
|
Tótoli EG, Garg S, Salgado HRN. Daptomycin: Physicochemical, Analytical, and Pharmacological Properties. Ther Drug Monit 2016; 37:699-710. [PMID: 26020161 DOI: 10.1097/ftd.0000000000000222] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Daptomycin is the first approved member of a new class of antimicrobials, the cyclic lipopeptides, and presents selective action against gram-positive bacteria, including methicillin- and vancomycin-resistant strains. Considering that resistance to daptomycin is rare, the drug has become very important for current clinical practice. This review covers daptomycin's physicochemical characteristics, antibacterial spectrum, mechanism of action, pharmacokinetics, clinical applications, side effects, drug interactions, and the analytical methods used to measure daptomycin in pharmaceutical products and biologic samples. Special attention has been given to therapeutic drug monitoring reports, as studies have shown its highly variable pharmacokinetics in specific circumstances, such as in patients suffering from critical illness, morbid obesity, severe sepsis, and kidney injury. For the same reason, methods described for therapeutic drug monitoring of daptomycin in the special patient population have been reviewed. In addition, the review presents a discussion of environmentally friendly analytical methods for daptomycin, which are necessary to reduce the impact of our activities on the environment. However, it was observed that there is a gap in the literature in this regard and further research involving the development of "green" methodologies for the analysis of daptomycin is necessary. The review will be useful to the clinical community in assisting with the responsible use of daptomycin, which is critical to prevent the emergence of resistant strains.
Collapse
Affiliation(s)
- Eliane Gandolpho Tótoli
- *School of Pharmaceutical Sciences, Universidade Estadual Paulista, Araraquara, Brazil; and †Centre for Pharmaceutical Innovation and Development (CPID), University of South Australia, Adelaide, Australia
| | | | | |
Collapse
|
22
|
Bagheri H, Banihashemi S, Jelvani S. A polythiophene–silver nanocomposite for headspace needle trap extraction. J Chromatogr A 2016; 1460:1-8. [DOI: 10.1016/j.chroma.2016.06.078] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Revised: 06/25/2016] [Accepted: 06/27/2016] [Indexed: 12/11/2022]
|
23
|
Christ AP, Machado MS, Ribas KG, Schwarzbold AV, Silva CDBD, Adams AIH. A fully validated microbiological assay for daptomycin injection and comparison to HPLC method. BRAZ J PHARM SCI 2015. [DOI: 10.1590/s1984-82502015000400003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
abstract Daptomycin (DPT) was the first lipopeptide antibiotic available for commercialization. It is active against gram-positive bacteria, including resistant strains. This work aimed to develop and validate a turbidimetric microbiologic assay to determine daptomycin in an injectable form. A 3x3 design was employed, at concentrations of 1, 2 and 4.0 µg/mL. The microorganism test used was Staphylococcus aureus ATCC 6538p, and Antibiotic Medium 3 was used as the culture medium. Method validation demonstrated that the bioassay was linear (r=0.9995), precise (RSD=2.58%), accurate (recovery 100.48± 2.11%), and robust. Degradation kinetics was also performed in an alkaline medium, indicating that daptomycin degradation follows first order kinetics under these conditions. The analyses of degraded solutions showed that daptomycin degradation products do not possess bactericidal activity. The bioassay was compared to HPLC method that was previously developed and no significant difference was found between them (p>0.05). The method proved to be appropriate for daptomycin injection quality control.
Collapse
|
24
|
Tótoli EG, Salgado HRN. A green approach for the quantification of daptomycin in pharmaceutical formulation by UV spectrophotometry. BRAZ J PHARM SCI 2015. [DOI: 10.1590/s1984-82502015000400007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
abstract Daptomycin is the first approved drug from a new class of antimicrobials, the cyclic lipopeptides, and is a very important antimicrobial agent in current clinical practice. Currently, there are no "green" analytical methods described in the literature to analyze the typical pharmaceutical dosage form of daptomycin. Thus, the aim of this work was to validate an environment-friendly spectrophotometric method in the UV region, for the analysis of daptomycin as a lyophilized powder. Water was used as diluent and the analyses were carried out on a spectrophotometer at 221 nm. The method met all validation requirements of the ICH guidelines, over a concentration range of 6-21 µg mL-1. A Student's t-test demonstrated that the proposed method was comparable to an HPLC method previously validated. Thus, the validated spectrophotometric method could quantify daptomycin in a powder form for injectable solutions, while being an economical, rapid, and "green" alternative for routine analysis in quality control.
Collapse
|
25
|
Szultka-Mlynska M, Olszowy P, Buszewski B. Nanoporous Conducting Polymer–Based Coatings in Microextraction Techniques for Environmental and Biomedical Applications. Crit Rev Anal Chem 2015; 46:236-47. [DOI: 10.1080/10408347.2015.1081051] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Malgorzata Szultka-Mlynska
- Department of Environmental Chemistry and Bioanalytics, Nicolaus Copernicus University, Toruń, Poland
- Interdisciplinary Centre for Modern Technologies, Nicolaus Copernicus University, Toruń, Poland
| | - Pawel Olszowy
- Department of Environmental Chemistry and Bioanalytics, Nicolaus Copernicus University, Toruń, Poland
- Interdisciplinary Centre for Modern Technologies, Nicolaus Copernicus University, Toruń, Poland
| | - Bogusław Buszewski
- Department of Environmental Chemistry and Bioanalytics, Nicolaus Copernicus University, Toruń, Poland
- Interdisciplinary Centre for Modern Technologies, Nicolaus Copernicus University, Toruń, Poland
| |
Collapse
|
26
|
Tótoli EG, Salgado HRN. Rapid Turbidimetric Assay to Determine the Potency of Daptomycin in Lyophilized Powder. Pharmaceutics 2015; 7:106-21. [PMID: 26184288 PMCID: PMC4588188 DOI: 10.3390/pharmaceutics7030106] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2015] [Revised: 07/02/2015] [Accepted: 07/02/2015] [Indexed: 11/16/2022] Open
Abstract
Daptomycin is an important antimicrobial for clinical practice, mainly because it remains very active against Gram-positive resistant strains, such as methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci. Development of microbiological methods for the analysis of antimicrobials is highly recommended, since they can provide important information about their biological activities, which physicochemical methods are not able to provide. Considering that there are no studies in the literature describing microbiological methods for the analysis of daptomycin, the aim of this work was to validate a microbiological method for the quantitation of daptomycin by the turbidimetric assay. Staphylococcus aureus was used as the test microorganism, and the brain heart infusion broth was used as the culture medium. The validation of the method was performed according to the ICH guidelines, and it was shown to be linear, precise, robust, accurate and selective, over a concentration range of 8.0 to 18.0 µg mL-1. Student's t-test showed the interchangeability of the proposed method with a previously-validated HPLC method. The developed turbidimetric method described in this paper is a convenient alternative for the routine quality control of daptomycin in its pharmaceutical dosage form.
Collapse
Affiliation(s)
- Eliane Gandolpho Tótoli
- School of Pharmaceutical Sciences, Universidade Estadual Paulista, Rod. Araraquara-Jaú, km 1, CEP 14801-902 Araraquara, SP, Brazil.
| | - Hérida Regina Nunes Salgado
- School of Pharmaceutical Sciences, Universidade Estadual Paulista, Rod. Araraquara-Jaú, km 1, CEP 14801-902 Araraquara, SP, Brazil.
| |
Collapse
|
27
|
Noroozian E, Rahimi M. Application of Poly(Pyrrole-co-Phenol) Electrosynthesized for Stir-Bar Sorptive Extraction of Polycyclic Aromatic Hydrocarbons and Liquid Chromatographic Analysis. J LIQ CHROMATOGR R T 2014. [DOI: 10.1080/10826076.2014.896815] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Ebrahim Noroozian
- a Department of Chemistry , Shahid Bahonar University of Kerman , Kerman , Iran
| | - Mina Rahimi
- a Department of Chemistry , Shahid Bahonar University of Kerman , Kerman , Iran
| |
Collapse
|
28
|
Rahimi M, Noroozian E. Frits coated with nano-structured conducting copolymer for solid-phase extraction of polycyclic aromatic hydrocarbons in water samples and liquid chromatographic analysis. Talanta 2014; 123:224-32. [DOI: 10.1016/j.talanta.2014.02.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Revised: 01/23/2014] [Accepted: 02/02/2014] [Indexed: 11/26/2022]
|
29
|
|
30
|
Buszewski B, Olszowy P, Pikus S, Kozak M. Electropolymerized nanoporous polymeric SPME coatings: preparation and characterization by small angle X-ray scattering and scanning electron microscopy. MONATSHEFTE FUR CHEMIE 2014; 145:527-531. [PMID: 26166891 PMCID: PMC4494846 DOI: 10.1007/s00706-013-1115-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/04/2013] [Accepted: 10/26/2013] [Indexed: 11/26/2022]
Abstract
ABSTRACT Polymeric polypyrrole and polythiophene solid phase microextraction (SPME) coatings were prepared using electropolymerization with a linear sweep voltammetry technique. Physicochemical properties were measured using different methods, in particular small angle X-ray scattering and scanning electron microscopy. By using innovative approaches for pore size measurement, we were able to calculate a maximum of the pore size range from 80 to 90 nm. Additionally, film thicknesses measured from 90 to 150 μm. Using scanning electron microscopy, we describe the characteristics of polymer growth on the support surface. GRAPHICAL ABSTRACT
Collapse
Affiliation(s)
- Boguslaw Buszewski
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, Gagarina 7, Torun, Poland
| | - Pawel Olszowy
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, Gagarina 7, Torun, Poland
| | - Stanislaw Pikus
- Department of Crystallography, Faculty of Chemistry, Maria Curie-Skłodowska University, Maria Curie-Skłodowska 3, 20-031 Lublin, Poland
| | - Maciej Kozak
- Department of Macromolecular Physics, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznan, Poland
| |
Collapse
|
31
|
Pereira J, Silva CL, Perestrelo R, Gonçalves J, Alves V, Câmara JS. Re-exploring the high-throughput potential of microextraction techniques, SPME and MEPS, as powerful strategies for medical diagnostic purposes. Innovative approaches, recent applications and future trends. Anal Bioanal Chem 2014; 406:2101-22. [DOI: 10.1007/s00216-013-7527-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2013] [Revised: 11/16/2013] [Accepted: 11/20/2013] [Indexed: 11/30/2022]
|
32
|
Banitaba MH, Hosseiny Davarani SS, Kazemi Movahed S. Comparison of direct, headspace and headspace cold fiber modes in solid phase microextraction of polycyclic aromatic hydrocarbons by a new coating based on poly(3,4-ethylenedioxythiophene)/graphene oxide composite. J Chromatogr A 2014; 1325:23-30. [DOI: 10.1016/j.chroma.2013.11.056] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2013] [Revised: 10/20/2013] [Accepted: 11/27/2013] [Indexed: 12/21/2022]
|
33
|
Pelit L, Dizdaş TN. Preparation and application of a polythiophene solid-phase microextraction fiber for the determination of endocrine-disruptor pesticides in well waters. J Sep Sci 2013; 36:3234-41. [DOI: 10.1002/jssc.201300633] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2013] [Revised: 07/23/2013] [Accepted: 07/23/2013] [Indexed: 11/06/2022]
Affiliation(s)
- Levent Pelit
- Department of Chemistry, Science Faculty, Ege University; Bornova İzmir Turkey
| | - Tuğberk Nail Dizdaş
- Department of Chemistry, Science Faculty, Ege University; Bornova İzmir Turkey
| |
Collapse
|
34
|
Li Y, Li W, Wang Y, Zhou H, Hu G, Zhang N, Sun C. Development of a solid-phase microextraction fiber coated with poly(methacrylic acid-ethylene glycol dimethacrylate) and its application for the determination of chlorophenols in water coupled with GC. J Sep Sci 2013; 36:2121-7. [DOI: 10.1002/jssc.201200979] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2012] [Revised: 04/19/2013] [Accepted: 04/19/2013] [Indexed: 11/09/2022]
Affiliation(s)
- Yongqiang Li
- State Key Laboratory of Pollution Control and Resource Reuse; School of the Environment, Nanjing University; Nanjing P. R. China
| | - Wenchao Li
- State Key Laboratory of Pollution Control and Resource Reuse; School of the Environment, Nanjing University; Nanjing P. R. China
| | - Yonghua Wang
- Key Laboratory of Integrated Regulation and Resource Department on Shallow Lakes; College of Environment, Hohai University; Nanjing P. R. China
| | - Haolin Zhou
- Agilent Technologies (Shanghai); Shanghai P. R. China
| | - Guanjiu Hu
- Environmental Monitor Center of Jiangsu Province; Nanjing P. R. China
| | - Ninghong Zhang
- Environmental Monitor Center of Jiangsu Province; Nanjing P. R. China
| | - Cheng Sun
- State Key Laboratory of Pollution Control and Resource Reuse; School of the Environment, Nanjing University; Nanjing P. R. China
| |
Collapse
|
35
|
Electrochemically prepared solid-phase microextraction coatings—A review. Anal Chim Acta 2013; 781:1-13. [DOI: 10.1016/j.aca.2013.03.012] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2012] [Revised: 02/25/2013] [Accepted: 03/01/2013] [Indexed: 11/21/2022]
|
36
|
Khodadoust S, Ghaedi M. Optimization of dispersive liquid-liquid microextraction with central composite design for preconcentration of chlordiazepoxide drug and its determination by HPLC-UV. J Sep Sci 2013; 36:1734-42. [DOI: 10.1002/jssc.201300085] [Citation(s) in RCA: 76] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2013] [Revised: 02/16/2013] [Accepted: 03/15/2013] [Indexed: 11/08/2022]
|
37
|
Conductive polymer-based microextraction methods: A review. Anal Chim Acta 2013; 767:1-13. [DOI: 10.1016/j.aca.2012.12.013] [Citation(s) in RCA: 140] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2012] [Revised: 12/06/2012] [Accepted: 12/08/2012] [Indexed: 11/22/2022]
|
38
|
Hu C, He M, Chen B, Hu B. A sol–gel polydimethylsiloxane/polythiophene coated stir bar sorptive extraction combined with gas chromatography-flame photometric detection for the determination of organophosphorus pesticides in environmental water samples. J Chromatogr A 2013; 1275:25-31. [DOI: 10.1016/j.chroma.2012.12.036] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2012] [Revised: 12/13/2012] [Accepted: 12/17/2012] [Indexed: 11/16/2022]
|
39
|
Farhadi K, Hatami M, Matin AA. Microextraction techniques in therapeutic drug monitoring. Biomed Chromatogr 2012; 26:972-89. [PMID: 22767149 DOI: 10.1002/bmc.2774] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2012] [Accepted: 05/11/2012] [Indexed: 11/08/2022]
Abstract
Therapeutic drug monitoring (TDM), as part of clinical process of medical treatments, is commonly used to maintain 'therapeutic' drug concentrations. TDM is useful to identify the causes of unwanted or unexpected responses, to prevent unnecessary diagnostic testing, to improve clinical outcomes, and even to save lives. The determination of drug concentration in blood samples requires an excellent sample preparation procedure. Recent trends in sample preparation include miniaturization, automation, high-throughput performance, on-line coupling with analytical instruments and low-cost operation through extremely low or no solvent consumption. Microextraction techniques, such as liquid- and solid-phase microextraction, have these advantages over the traditional techniques. This paper reviews the recent developments in microextraction techniques used for drug monitoring in serum, plasma or blood samples.
Collapse
Affiliation(s)
- Khalil Farhadi
- Department of Chemistry, Faculty of Science, Urmia University, Iran.
| | | | | |
Collapse
|
40
|
Cobzac SC, Gocan S. CHROMATOGRAPHY: RECENT PROGRESS. J LIQ CHROMATOGR R T 2012. [DOI: 10.1080/10826076.2011.647193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
41
|
Mehdinia A, Bashour F, Roohi F, Jabbari A, Saleh A. Preparation and evaluation of thermally stable nano-structured self-doped polythiophene coating for analysis of phthalate ester trace levels. J Sep Sci 2012; 35:563-70. [DOI: 10.1002/jssc.201100713] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
42
|
Rani S, Malik AK, Singh B. Novel micro-extraction by packed sorbent procedure for the liquid chromatographic analysis of antiepileptic drugs in human plasma and urine. J Sep Sci 2012; 35:359-66. [DOI: 10.1002/jssc.201100789] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
43
|
Olszowy P, Szultka M, Nowaczyk J, Buszewski B. A new way of solid-phase microextraction fibers preparation for selected antibiotic drug determination by HPLC–MS. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:2542-8. [DOI: 10.1016/j.jchromb.2011.07.007] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2011] [Revised: 06/01/2011] [Accepted: 07/07/2011] [Indexed: 11/27/2022]
|
44
|
Cobzac SC, Gocan S. SAMPLE PREPARATION FOR HIGH PERFORMANCE LIQUID CHROMATOGRAPHY: RECENT PROGRESS. J LIQ CHROMATOGR R T 2011. [DOI: 10.1080/10826076.2011.588064] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Affiliation(s)
- Simona Codruta Cobzac
- a Department of Analytical Chemistry, Faculty of Chemistry and Chemical Engineering , Babes-Bolyai University , Cluj Napoca, Romania
| | - Simion Gocan
- a Department of Analytical Chemistry, Faculty of Chemistry and Chemical Engineering , Babes-Bolyai University , Cluj Napoca, Romania
| |
Collapse
|
45
|
Olszowy P, Szultka M, Buszewski B. Poly(3-alkylthiophenes): new sorption materials for solid phase microextraction of drugs isolated from human plasma. Anal Bioanal Chem 2011; 401:1377-84. [PMID: 21710286 PMCID: PMC3151406 DOI: 10.1007/s00216-011-5159-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2011] [Revised: 05/30/2011] [Accepted: 06/02/2011] [Indexed: 11/28/2022]
Abstract
A novel sorbent in solid phase microextraction (SPME) method based on poly(3-alkylthiophenes) was used in the isolation of linezolid from human plasma samples following liquid chromatography determination. The effect of extraction time on the sorption capacity of the SPME process was studied and pointed at 10 min both for adsorption and desorption. Poly(3-methylthiophene) and poly(3-nonylthiophene) were applied for the extraction of linezolid from water solutions. In plasma samples, four coatings including polythiophene and poly(3-penthylthiophene) were investigated. With these measurements, correlation coefficients were calculated in the range from 0.9820 to 0.9995, and the relative standard deviations were below 15%. That allowed claiming that the synthesized and described materials can be successfully applied in the analysis of linezolid also from other matrices such as urine or blood.
Collapse
Affiliation(s)
- Pawel Olszowy
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, Torun, Poland
| | | | | |
Collapse
|
46
|
Kataoka H, Saito K. Recent advances in SPME techniques in biomedical analysis. J Pharm Biomed Anal 2011; 54:926-50. [DOI: 10.1016/j.jpba.2010.12.010] [Citation(s) in RCA: 143] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2010] [Revised: 12/06/2010] [Accepted: 12/09/2010] [Indexed: 10/18/2022]
|
47
|
KATAOKA H. Current Developments and Future Trends in Solid-phase Microextraction Techniques for Pharmaceutical and Biomedical Analyses. ANAL SCI 2011; 27:893-905. [DOI: 10.2116/analsci.27.893] [Citation(s) in RCA: 81] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|