1
|
Reza Zaimbashi, Hadi Beitollahi. Electrochemical Sensor for Detection of Hydrochlorothiazide Based on Screen-Printed Electrode Modified with ZnO/Al2O3 Nanocomposite. SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY 2022. [DOI: 10.3103/s1068375522060163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
2
|
Box–Behnken experimental design for optimizing the HPLC method to determine hydrochlorothiazide in pharmaceutical formulations and biological fluid. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.118708] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
3
|
Yıldırım S, Demirdaş G, Fidan M, Yaşar A. Simple and Fast Determination of Terbinafine in Human Urine by Dilute and Shoot HPLC-DAD Using a Core-Shell Column. Comb Chem High Throughput Screen 2020; 24:342-351. [PMID: 32646357 DOI: 10.2174/1386207323666200709171504] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/12/2020] [Accepted: 04/21/2020] [Indexed: 11/22/2022]
Abstract
BACKGROUND Terbinafine is an allylamine antifungal that is effective against many fungi, dermatophytes and moulds. Analytical methods are required for the determination of terbinafine in biological fluids to perform therapeutic drug monitoring and pharmacokinetic studies. OBJECTIVE The aim of this study was to develop and validate a novel and fast method combining dilute and shoot approach and high-performance liquid chromatography coupled with photodiode array detection for the determination of terbinafine in human urine. METHODS Chromatographic parameters including mobile phase composition, pH, flow rate and injection volume were assessed and optimized. The separation of terbinafine and naproxen (internal standard) was achieved within 3 min using a C18 core-shell column (Raptor ARC-18, 100 x 4.6 mm, 2.7 μm) under isocratic conditions. Samples were eluted from the column at the flow rate of 1.4 mL/min using a mobile phase containing 0.2% triethylamine in water (pH 3.4 with formic acid): acetonitrile (45:55, v/v). RESULTS The presented technique was linear in the range of 25-2000 ng/mL. Intra- and inter-day reproducibility at four quality control levels (25, 200, 750 and 1500 ng/mL) were less than 7%, with relative errors ranging from -5.40% to 5.91%. The limit of detection was 12.60 ng/mL. The developed method has three main advantages compared to existing methods: simplicity and greenness of sample preparation, use of core-shell column and short analysis time. CONCLUSION The results of this study indicate that the combination of dilute and shoot approach and core-shell column can be regarded as an advantageous application for the fast determination of terbinafine in the urine.
Collapse
Affiliation(s)
- Sercan Yıldırım
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Trabzon, Turkey
| | - Gökhan Demirdaş
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Trabzon, Turkey
| | - Mert Fidan
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Trabzon, Turkey
| | - Ahmet Yaşar
- Department of Analytical Chemistry, Faculty of Pharmacy, Karadeniz Technical University, Trabzon, Turkey
| |
Collapse
|
4
|
Staniak M, Wójciak M, Sowa I, Tyszczuk-Rotko K, Strzemski M, Dresler S, Myśliński W. Silica-Based Monolithic Columns as a Tool in HPLC-An Overview of Application in Analysis of Active Compounds in Biological Samples. Molecules 2020; 25:molecules25143149. [PMID: 32660127 PMCID: PMC7397265 DOI: 10.3390/molecules25143149] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 07/02/2020] [Accepted: 07/06/2020] [Indexed: 01/08/2023] Open
Abstract
Monolithic fillings used in chromatography are of great interest among scientists since the first reports of their synthesis and use were published. In the 20 years since silica-based monolithic columns were introduced into the commercial market, numerous papers describing their chromatographical properties and utility in various branches of industry and scientific investigations were presented. This review is focused on possible applications of commercially available silica-based HPLC monolithic columns in the analysis of biological samples.
Collapse
Affiliation(s)
- Michał Staniak
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
- Correspondence: (M.S.); (M.W.)
| | - Magdalena Wójciak
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
- Correspondence: (M.S.); (M.W.)
| | - Ireneusz Sowa
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
| | - Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University Lublin, 20-031 Lublin, Poland;
| | - Maciej Strzemski
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
| | - Sławomir Dresler
- Department of Plant Physiology and Biophysics, Maria Curie-Skłodowska University, 20-033 Lublin, Poland;
| | - Wojciech Myśliński
- Chair and Department of Internal Diseases, Medical University of Lublin, 20-081 Lublin, Poland;
| |
Collapse
|
5
|
Abstract
Recently, high demand of high-throughput analyses with high sensitivity and selectivity to molecules and drugs in different classes with different physical-chemical properties—and a reduction in analysis time—is a principal milestone for novel methodologies that researchers are trying to achieve—especially when analytical procedures are applied to clinical purposes. In addition, to avoid high doses of a single drug that could cause serious side effects, multi-drug therapies are often used to treat numerous diseases. For these reasons, the demand for methods that allow the rapid analysis of mixed compounds has increased in recent years. In order to respond to these needs, new methods and instruments have been developed. However, often the complexity of a matrix can require a long time for the preparation and processing of the samples. Different problems in terms of components, types of matrices, compounds and physical-chemical complexity are encountered when considering drugs association profiles for quantitative analyses. This review addresses not only recently optimized procedures such as chromatographic separation, but also methods that have allowed us to obtain accuracy (precision and trueness), sensitivity and selectivity in quantitative analyses for cases of drug associations.
Collapse
|
6
|
Ashour S, Bayram R. Selective and validated kinetic spectrophotometric method for the determination of irbesartan in pure and pharmaceutical formulations. ANNALES PHARMACEUTIQUES FRANÇAISES 2018; 77:101-111. [PMID: 30471775 DOI: 10.1016/j.pharma.2018.09.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 09/05/2018] [Accepted: 09/06/2018] [Indexed: 11/26/2022]
Abstract
A novel-coupling reagent is used for the simple and sensitive kinetic spectrophotometric determination of irbesartan (IRB) in pure or pharmaceutical formulations. The method utilizes an oxidative coupling reaction based on oxidation of 3-methyl-2-benzothiazolinone hydrazone hydrochloride monohydrate (MBTH) with Ce(IV) in 2% sulfuric acid medium, followed by coupling the produced electrophilic intermediate (diazonium salt of the reagent) with IRB to give greenish-blue colored product (1:1, stoichiometry) having maximum absorption at 629nm and the colored species is stable for more than 1h. The initial rate and fixed time (at 35min) methods are adopted for determination of IRB concentration. The linearity is in the ranges of 5.0-40.0μg/mL and 2.0-45.0μg/mL and the limit of detection is 0.46 and 0.40μg/mL for initial rate and fixed time methods, respectively. Molar absorptivity for the method was found to be 1.50×104L/molcm. The validated kinetic methods can be successfully applied to the analysis of IRB in bulk and tablet dosage form and in the routine quality control analysis. The percentage recoveries were above 100% for both methods. The excipients did not interfere in the analysis.
Collapse
Affiliation(s)
- S Ashour
- Department of Chemistry, Faculty of Sciences, Aleppo University, Aleppo, Syria.
| | - R Bayram
- Departments of Pharmaceutical Chemistry, Pharmacy Program, Batterjee Medical College, Jeddah, Saudi Arabia
| |
Collapse
|
7
|
Fast and sensitive LC-MS/MS method for the simultaneous determination of lisinopril and hydrochlorothiazide in human plasma. J Pharm Anal 2018. [PMID: 29404033 DOI: 10.1016/j.jpha.2016.11.004.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
A sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the simultaneous determination of lisinopril (LIS) and hydrochlorothiazide (HCTZ) in human plasma using their labeled internal standards (ISs). Sample pre-treatment involved solid phase extraction on Waters Oasis HLB cartridges using 100 µL of plasma, followed by liquid chromatography on Hypersil Gold C18 (50 mm×3.0 mm, 5 µm) column. The analytes were eluted within 2.0 min using acetonitrile-5.0 mM ammonium formate, pH 4.5 (85:15, v/v) as the mobile phase. The analytes and ISs were analyzed in the negative ionization mode and quantified using multiple reaction monitoring. The method showed excellent linearity over the concentration range of 0.50-250.0 ng/mL for both the analytes. The intra-batch and inter-batch precision (% CV) was ≤5.26% and their extraction recoveries were in the range of 96.6%-103.1%. Matrix effect evaluated in terms of IS-normalized matrix factors ranged from 0.97 to 1.03 for both the analytes. The validated method was successfully applied to determine the plasma concentration of the drugs using 10 mg lisinopril and 12.5 mg hydrochlorothiazide fixed dose formulation in 18 healthy Indian volunteers.
Collapse
|
8
|
Shah JV, Parekh JM, Shah PA, Shah PV, Sanyal M, Shrivastav PS. Application of an LC-MS/MS method for the analysis of amlodipine, valsartan and hydrochlorothiazide in polypill for a bioequivalence study. J Pharm Anal 2018; 7:309-316. [PMID: 29404054 PMCID: PMC5790699 DOI: 10.1016/j.jpha.2017.06.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2017] [Revised: 04/16/2017] [Accepted: 06/02/2017] [Indexed: 12/02/2022] Open
Abstract
A sensitive and selective method has been proposed for the simultaneous determination of amlodipine (AML), valsartan (VAL) and hydrochlorothiazide (HCTZ) in human plasma by liquid chromatography–tandem mass spectrometry (LC–MS/MS). The analytes and their deuterated analogs were quantitatively extracted from 100 µL human plasma by solid phase extraction on Oasis HLB cartridges. The chromatographic separation of the analytes was achieved on a Chromolith RP18e (100 mm × 4.6 mm) analytical column within 2.5 min. The resolution factor between AML and VAL, AML and HCTZ, and VAL and HCTZ was 2.9, 1.5 and 1.4, respectively, under isocratic conditions. The method was validated over a dynamic concentration range of 0.02–20.0 ng/mL for AML, 5.00–10,000 ng/mL for VAL and 0.20–200 ng/mL for HCTZ. Ion-suppression/enhancement effects were investigated by post-column infusion technique. The mean IS-normalized matrix factors for AML, VAL and HCTZ were 0.992, 0.994 and 0.998, respectively. The intra-batch and inter-batch precision (% CV) across quality control levels was ≤ 5.56% and the recovery was in the range of 93.4%–99.6% for all the analytes. The method was successfully applied to a bioequivalence study of 5 mg AML + 160 mg VAL + 12.5 mg HCTZ tablet formulation (test and reference) in 18 healthy Indian males under fasting. The mean log-transformed ratios of Cmax, AUC0–120h and AUC0-inf and their 90% CIs were within 90.2%–102.1%. The assay reproducibility was demonstrated by reanalysis of 90 incurred samples.
Collapse
Affiliation(s)
- Jaivik V Shah
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad 380009, India
| | - Jignesh M Parekh
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad 380009, India
| | - Priyanka A Shah
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad 380009, India
| | - Priya V Shah
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad 380009, India.,Department of Chemistry, St. Xavier's College, Navrangpura, Ahmedabad 380009, India.,Department of Pharmacy, M. S. University, Pratapgunj, Vadodara 390002, India
| | - Mallika Sanyal
- Department of Chemistry, St. Xavier's College, Navrangpura, Ahmedabad 380009, India
| | - Pranav S Shrivastav
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad 380009, India
| |
Collapse
|
9
|
Fast and sensitive LC-MS/MS method for the simultaneous determination of lisinopril and hydrochlorothiazide in human plasma. J Pharm Anal 2018; 7:163-169. [PMID: 29404033 PMCID: PMC5790688 DOI: 10.1016/j.jpha.2016.11.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Revised: 11/23/2016] [Accepted: 11/24/2016] [Indexed: 01/19/2023] Open
Abstract
A sensitive and rapid liquid chromatography-tandem mass spectrometry (LC–MS/MS) method has been developed for the simultaneous determination of lisinopril (LIS) and hydrochlorothiazide (HCTZ) in human plasma using their labeled internal standards (ISs). Sample pre-treatment involved solid phase extraction on Waters Oasis HLB cartridges using 100 µL of plasma, followed by liquid chromatography on Hypersil Gold C18 (50 mm×3.0 mm, 5 µm) column. The analytes were eluted within 2.0 min using acetonitrile-5.0 mM ammonium formate, pH 4.5 (85:15, v/v) as the mobile phase. The analytes and ISs were analyzed in the negative ionization mode and quantified using multiple reaction monitoring. The method showed excellent linearity over the concentration range of 0.50–250.0 ng/mL for both the analytes. The intra-batch and inter-batch precision (% CV) was ≤5.26% and their extraction recoveries were in the range of 96.6%–103.1%. Matrix effect evaluated in terms of IS-normalized matrix factors ranged from 0.97 to 1.03 for both the analytes. The validated method was successfully applied to determine the plasma concentration of the drugs using 10 mg lisinopril and 12.5 mg hydrochlorothiazide fixed dose formulation in 18 healthy Indian volunteers.
Collapse
|
10
|
Shah JV, Shah PA, Sanyal M, Shrivastav PS. Simultaneous quantification of amiloride and hydrochlorothiazide in human plasma by liquid chromatography-tandem mass spectrometry. J Pharm Anal 2017; 7:288-296. [PMID: 29404051 PMCID: PMC5790693 DOI: 10.1016/j.jpha.2017.03.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2016] [Revised: 03/06/2017] [Accepted: 03/23/2017] [Indexed: 11/17/2022] Open
Abstract
A selective, sensitive and precise assay based on solid phase extraction and liquid chromatography–tandem mass spectrometry (LC–MS/MS) was developed for the simultaneous determination of amiloride (AMI) and hydrochlorothiazide (HCTZ) in human plasma. Sample clean-up with 250 µL of plasma was done on Phenomenex Strata™-X extraction cartridges using their labeled internal standards (AMI-15N3 and HCTZ-13C,d2). Chromatography was performed on Hypersil Gold C18 (50 mm×3.0 mm, 5 µm) column using acetonitrile with 4.0 mM ammonium formate (pH 4.0, adjusted with 0.1% formic acid) (80:20, v/v) as the mobile phase. Detection was carried out on a triple quadrupole API 5500 mass spectrometer utilizing an electrospray ionization interface and operating in the positive ionization mode for AMI and negative ionization mode for HCTZ. Multiple reaction monitoring was used following the transitions at m/z 230.6/116.0, m/z 233.6/116.0, m/z 296.0/204.9 and m/z 299.0/205.9 for AMI, AMI-15N3, HCTZ and HCTZ-13C,d2, respectively. Calibration curves were linear (r2≥0.9997) over the concentration range of 0.050–50.0 and 0.50–500 ng/mL for AMI and HCTZ, respectively, with acceptable accuracy and precision. The signal-to-noise ratio at the limit of quantitation was ≥14 for both the analytes. The mean recovery of AMI and HCTZ from plasma was 89.0% and 98.7%, respectively. The IS-normalized matrix factors determined for matrix effect ranged from 0.971 to 1.024 for both the analytes. The validated LC–MS/MS method was successfully applied to a bioequivalence study using 5 mg AMI and 50 mg HCTZ fixed dose tablet formulation in 18 healthy Indian volunteers with good reproducibility.
Collapse
Affiliation(s)
- Jaivik V Shah
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad 380009, India
| | - Priyanka A Shah
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad 380009, India
| | - Mallika Sanyal
- Department of Chemistry, St. Xavier's College, Navrangpura, Ahmedabad 380009, India
| | - Pranav S Shrivastav
- Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad 380009, India
| |
Collapse
|
11
|
Arase S, Horie K, Kato T, Noda A, Mito Y, Takahashi M, Yanagisawa T. Intelligent peak deconvolution through in-depth study of the data matrix from liquid chromatography coupled with a photo-diode array detector applied to pharmaceutical analysis. J Chromatogr A 2016; 1469:35-47. [PMID: 27712885 DOI: 10.1016/j.chroma.2016.09.037] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 08/24/2016] [Accepted: 09/19/2016] [Indexed: 10/21/2022]
Abstract
Multivariate curve resolution-alternating least squares (MCR-ALS) method was investigated for its potential to accelerate pharmaceutical research and development. The fast and efficient separation of complex mixtures consisting of multiple components, including impurities as well as major drug substances, remains a challenging application for liquid chromatography in the field of pharmaceutical analysis. In this paper we suggest an integrated analysis algorithm functioning on a matrix of data generated from HPLC coupled with photo-diode array detector (HPLC-PDA) and consisting of the mathematical program for the developed multivariate curve resolution method using an expectation maximization (EM) algorithm with a bidirectional exponentially modified Gaussian (BEMG) model function as a constraint for chromatograms and numerous PDA spectra aligned with time axis. The algorithm provided less than ±1.0% error between true and separated peak area values at resolution (Rs) of 0.6 using simulation data for a three-component mixture with an elution order of a/b/c with similarity (a/b)=0.8410, (b/c)=0.9123 and (a/c)=0.9809 of spectra at peak apex. This software concept provides fast and robust separation analysis even when method development efforts fail to achieve complete separation of the target peaks. Additionally, this approach is potentially applicable to peak deconvolution, allowing quantitative analysis of co-eluted compounds having exactly the same molecular weight. This is complementary to the use of LC-MS to perform quantitative analysis on co-eluted compounds using selected ions to differentiate the proportion of response attributable to each compound.
Collapse
Affiliation(s)
- Shuntaro Arase
- Eisai Co., Ltd., Formulation Research, Pharmaceutical Science & Technology Core Function Unit, Medicine Development Center, Kawashima, Kakamigahara, Gifu 501-6195, Japan
| | - Kanta Horie
- Eisai Co., Ltd., Translational Medicine Department, Medicine Creation, Neurology Business Group, Tokodai, Tsukuba, Ibaraki 300-2635, Japan.
| | - Takashi Kato
- Eisai Co., Ltd., Formulation Research, Pharmaceutical Science & Technology Core Function Unit, Medicine Development Center, Kawashima, Kakamigahara, Gifu 501-6195, Japan
| | - Akira Noda
- Shimadzu Corporation, Technology Research Laboratory, Hikaridai, Seika-cho, Soraku-gun, Kyoto 619-0237, Japan
| | - Yasuhiro Mito
- Shimadzu Corporation, Research & Development Department, Analytical & Measuring Instruments Division, Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511, Japan
| | - Masatoshi Takahashi
- Shimadzu Corporation, Research & Development Department, Analytical & Measuring Instruments Division, Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511, Japan
| | - Toshinobu Yanagisawa
- Shimadzu Corporation, Research & Development Department, Analytical & Measuring Instruments Division, Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511, Japan.
| |
Collapse
|