1
|
Movilla-Meza NA, Sierra-Vega NO, Alvarado-Hernández BB, Méndez R, Romañach RJ. The Use of a Closed Feed Frame for the Development of Near-Infrared Spectroscopic Calibration Model to Determine Drug Concentration. Pharm Res 2023; 40:2903-2916. [PMID: 37700106 DOI: 10.1007/s11095-023-03601-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 08/31/2023] [Indexed: 09/14/2023]
Abstract
PURPOSE This study evaluates the use of the closed feed frame as a material sparing approach to develop near-infrared (NIR) spectroscopic calibration models for monitoring blend uniformity. The effect of shear induced by recirculation on NIR spectra was also studied. METHODS Calibration models were developed using NIR spectra obtained in the closed feed frame for two cases. For case 2, blends that flowed through the open feed frame were predicted with the model. The shear effect of the feed frame on the blends was assessed through the characterization of powder properties before and after recirculation. RESULTS The physical characterization of the blends confirmed that the powder properties were not altered after recirculation within the closed feed frame. Both calibration models provided highly accurate predictions of the test sets with low bias (0.03% w/w and -0.06% w/w) and relative standard error of prediction (1.9% and 3.7%), respectively. The predictive performance of the calibration models was not affected by the shear effect. CONCLUSION Recirculation within the closed feed frame did not change the physical properties of the blends studied. The prediction of blends flowing through the open feed frame was possible with a calibration model developed in the closed feed frame. The closed feed frame could reduce the materials needed to develop calibration models by more than 90%.
Collapse
Affiliation(s)
| | - Nobel O Sierra-Vega
- Department of Chemical Engineering, University of Puerto Rico at Mayagüez, Mayagüez, PR, USA
| | | | - Rafael Méndez
- Department of Chemical Engineering, University of Puerto Rico at Mayagüez, Mayagüez, PR, USA
| | - Rodolfo J Romañach
- Department of Chemistry, University of Puerto Rico at Mayagüez, Mayagüez, PR, USA.
- Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemistry, University of Puerto Rico at Mayagüez, PO Box 9000, Mayagüez, PR, 00681, USA.
| |
Collapse
|
2
|
Rubio AA, Conrad S, Juzaitis-Boelter C, Wishon CR, Fahrenholz AC. The impact of marker selection, in-line near-infrared spectroscopy (NIR), and feed mix time on the coefficient of variation (mix uniformity), body weight uniformity and broiler growth performance during the starter, grower, and finisher periods. Poult Sci 2023; 102:103109. [PMID: 37832185 PMCID: PMC10568556 DOI: 10.1016/j.psj.2023.103109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 09/01/2023] [Accepted: 09/07/2023] [Indexed: 10/15/2023] Open
Abstract
Most feed manufacturers in the United States use the same mixing time (and thus mix uniformity) throughout the growing period regardless of age and consumption patterns. However, research evaluating the optimum mixing time requirements and novel analysis methods, such as in-line near-infrared (NIR) spectroscopy, on the coefficient of variation (CV) and growth performance of broilers throughout the production phases is sparse. Two experiments were conducted to determine the effects of marker selection, in-line NIR, and varying mix times on mix uniformity, broiler growth performance, and body weight uniformity from 1 to 42 d of age. Feed was manufactured utilizing a 1,815-kg counterpoise ribbon mixer. In both experiments, feed was mixed for 4.5 min (3 min dry mix and 90 s of wet mix) and 30 s (0 s dry mix and 30 s wet mix) to obtain a standard mix (SM) and an abbreviated mix (AM), respectively. Experiment 1 constituted a 2 × 2 × 4 factorial arrangement of 2 mix times, (4.5 and 0.5 min), 2 batch sizes (908 and 1,815 kg), and 4 methodologies to evaluate mixer performance (sodium chloride, Microtracers (Red#40 and Blue#40), and in-line NIR). In experiment 2, broilers received different mix time combinations: 1) SM from 1 to 42 d, 2) SM from 1 to 28 d and AM from 28 to 42 d, 3) SM from 1 to 14 d and AM from 14 to 42 d, and 4) AM from 1 to 42 d. In both experiments, selecting a single source marker provided a more accurate estimation of mixer CV in SM and AM diets (P < 0.05). In experiment 2, mix time did not influence BW, feed intake (FI), FCR, or individual bird BW CV from 1 to 42 d of age (P > 0.05). These data indicated that mixer CV differed depending on total mix time and methodology used and diets with a reduced mix time may not necessarily influence growth performance and BW uniformity during the starter, grower, and finisher periods of broilers.
Collapse
Affiliation(s)
- A A Rubio
- Prestage Department of Poultry Science, North Carolina State University, Raleigh, NC 27607, USA
| | - S Conrad
- Bruker Corporation, Billerica, MA 01821, USA
| | | | - C R Wishon
- Prestage Department of Poultry Science, North Carolina State University, Raleigh, NC 27607, USA
| | - A C Fahrenholz
- Prestage Department of Poultry Science, North Carolina State University, Raleigh, NC 27607, USA.
| |
Collapse
|
3
|
Rish AJ, Henson SR, Velez-Silva NL, Nahid Hasan M, Drennen JK, Anderson CA. Application of a wavelength angle mapper for variable selection in iterative optimization technology predictions of drug content in pharmaceutical powder mixtures. Int J Pharm 2023; 643:123261. [PMID: 37479099 DOI: 10.1016/j.ijpharm.2023.123261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 07/11/2023] [Accepted: 07/18/2023] [Indexed: 07/23/2023]
Abstract
Process analytical technology (PAT) is an essential tool within pharmaceutical manufacturing to ensure consistent quality and maintain process control. Near-infrared (NIR) spectroscopy is one of the most popular PAT techniques, particularly for monitoring active pharmaceutical ingredient (API) concentrations. To interpret the spectral outputs of NIR spectroscopy, advanced multivariate models are required. Calibration-free models such as iterative optimization technology (IOT) algorithms are increasingly of interest, due primarily to their reduced material and time burdens. Variable/wavelength selection is a common method to improve prediction performance and robustness for IOT by focusing on spectral regions with the most relevant information. However, currently proposed wavelength selection approaches rely on training sets for optimization, therefore reducing or removing the advantages of IOT over empirical calibration-dependent models. In this work, a true calibration-free wavelength selection method is proposed based on measuring the difference between individual wavelengths of a mixture spectra and the net analyte signals via a wavelength angle mapper (WAM). An extension of the WAM utilizing a spectral window of wavelength instead of individual wavelengths, called SWAM, was also developed. However, the SWAM method does require a small training set to optimize wavelength selection parameters. The WAM and SWAM methods showed similar prediction performance for API in pharmaceutical powder blends when compared against other calibration-dependent models and the base IOT algorithm.
Collapse
Affiliation(s)
- Adam J Rish
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA
| | - Samuel R Henson
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA
| | - Natasha L Velez-Silva
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA
| | - Md Nahid Hasan
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA
| | - James K Drennen
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA; Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, USA
| | - Carl A Anderson
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA; Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, USA.
| |
Collapse
|
4
|
Parameter optimization in a continuous direct compression process of commercially batch-produced bisoprolol tablets. Int J Pharm 2022; 628:122355. [DOI: 10.1016/j.ijpharm.2022.122355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 10/24/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022]
|
5
|
Zheng C, Yost E, Muliadi AR, Govender N, Zhang L, Wu CY. Numerical analysis of die filling with a forced feeder using GPU-enhanced discrete element methods. Int J Pharm 2022; 622:121861. [PMID: 35643345 DOI: 10.1016/j.ijpharm.2022.121861] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 05/11/2022] [Accepted: 05/22/2022] [Indexed: 11/16/2022]
Abstract
Understanding die filling behaviour of powders is critical in developing optimal formulation and processes in various industries, such as pharmaceuticals and fine chemicals. In this paper, forced die filling is analysed using a graphics processing unit (GPU) based discrete element method (DEM), for which a powder feeder equipped with a wired stirrer is considered. The influences of operating parameters, such as the initial powder bed height, the filling speed, and the stirrer speed, on the die filling performance are systematically explored. It is shown that a larger initial powder bed height leads to a higher filling ratio, which can be attributed to a higher filling intensity; while the deposited particle mass in the die is almost independent of the powder bed height, when the initial fill level is larger than a critical bed height. Additionally, the filling ratio slightly increases with the increase of stirrer speed for cases with a stirrer, while the filling ratios are lower than that without a stirrer, which is attributed to the stirrer occupying some space above the die and reducing the effective discharge area. The obtained results can provide useful information for optimising the feeder system design and the operating condition.
Collapse
Affiliation(s)
- Chao Zheng
- Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, United Kingdom
| | - Edward Yost
- Small Molecule Pharmaceutical Sciences, Genentech, South San Francisco, CA 94080, USA
| | - Ariel R Muliadi
- Small Molecule Pharmaceutical Sciences, Genentech, South San Francisco, CA 94080, USA
| | - Nicolin Govender
- Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, United Kingdom
| | - Ling Zhang
- Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, United Kingdom
| | - Chuan-Yu Wu
- Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, United Kingdom.
| |
Collapse
|
6
|
Robert G, Dalvi H, Lavoie FB, Abatzoglou N, Gosselin R. Pharmaceutical tablet compression: measuring temporal and radial concentration profiles to better assess segregation. Pharm Dev Technol 2022; 27:448-458. [PMID: 35583396 DOI: 10.1080/10837450.2022.2078348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Concentration monitoring inside a tablet press feed frame is important not only to assess the composition of the powder blend being compressed into tablets but also to detect quality affecting phenomena such as powder segregation. Near infrared spectroscopy has been successfully used to monitor powder concentration inside feed frame; however, so far, this methodology does not provide information on local spatial variability, since it probes a very small area of powder sample. Near infrared chemical imaging (NIR CI) has the potential to improve process monitoring because it can simultaneously acquire a plurality of spectra covering nearly the entire width of feed frame, thereby making it possible to detect local variations in powder concentration.The present work uses both NIRS and NIR CI to monitor the concentration of Ibuprofen and Ascorbic acid in multi-component mock pharmaceutical blends flowing through the feed frame of an industrial tablet press. The concentrations of Ibuprofen and Ascorbic acid were successfully monitored in multi-component powder blends. NIR spectral wavelength ranges and pre-treatments were simultaneously optimized via a genetic algorithm. N-way PLS approach for concentration monitoring was found to be more suitable than regular PLS when analyzing spectral images and provided the ability to visualize spatial segregation.
Collapse
Affiliation(s)
- Giverny Robert
- Department of Chemical & Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, Québec, Canada
| | - Himmat Dalvi
- Department of Chemical & Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, Québec, Canada
| | - Francis B Lavoie
- Department of Chemical & Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, Québec, Canada
| | - Nicolas Abatzoglou
- Department of Chemical & Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, Québec, Canada
| | - Ryan Gosselin
- Department of Chemical & Biotechnological Engineering, Université de Sherbrooke, Sherbrooke, Québec, Canada
| |
Collapse
|
7
|
Rish AJ, Henson SR, Anik Alam M, Liu Y, Drennen JK, Anderson CA. Development of calibration-free/minimal calibration wavelength selection for iterative optimization technology algorithms toward process analytical technology application. Int J Pharm 2022; 614:121463. [PMID: 35026311 DOI: 10.1016/j.ijpharm.2022.121463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 01/06/2022] [Accepted: 01/07/2022] [Indexed: 10/19/2022]
Abstract
As continuous manufacturing (CM) processes are developed, process analytical technology (PAT) via NIR spectroscopy has become an integral tool in process monitoring. NIR spectroscopy requires the deployment of complex multivariate models to extract the relevant information. The model of choice for the pharmaceutical industry is Partial Least Squares (PLS). However, the development of PLS can be burdensome due to the time and resource intensive requirements of calibration. To overcome this challenge, calibration-free/minimal calibration approaches have become of increasing interest. Iterative optimization technology (IOT) algorithms are a favorable calibration-free/minimal calibration approach with only the requirement of pure component spectra for successful active pharmaceutical ingredient (API) quantification. IOT algorithms were utilized to monitor potency trends (qualitative) and API content (quantitative) in a CM system and compared to a traditional PLS model. To overcome the reduced prediction performance of IOT during non-steady state conditions, a novel wavelength method based on variable importance in projection scores was employed. Overall, the success and value of IOT algorithms for application in CM settings was demonstrated.
Collapse
Affiliation(s)
- Adam J Rish
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA
| | - Samuel R Henson
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA
| | - Md Anik Alam
- Worldwide Research and Development, Pfizer Inc., Groton, CT 06340, USA
| | - Yang Liu
- Worldwide Research and Development, Pfizer Inc., Groton, CT 06340, USA
| | - James K Drennen
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA; Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, USA
| | - Carl A Anderson
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, USA; Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, USA.
| |
Collapse
|
8
|
Velez NL, Drennen JK, Anderson CA. Challenges, opportunities and recent advances in near infrared spectroscopy applications for monitoring blend uniformity in the continuous manufacturing of solid oral dosage forms. Int J Pharm 2022; 615:121462. [PMID: 35026317 DOI: 10.1016/j.ijpharm.2022.121462] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 12/20/2021] [Accepted: 01/07/2022] [Indexed: 10/19/2022]
Abstract
Near infrared (NIR) spectroscopy has been widely recognized as a powerful PAT tool for monitoring blend uniformity in continuous manufacturing (CM) processes. However, the dynamic nature of the powder stream and the fast rate at which it moves, compared to batch processes, introduces challenges to NIR quantitative methods for monitoring blend uniformity. For instance, defining the effective sample size interrogated by NIR, selecting the best sampling location for blend monitoring, and ensuring NIR model robustness against influential sources of variability are challenges commonly reported for NIR applications in CM. This article reviews the NIR applications for powder blend monitoring in the continuous manufacturing of solid oral dosage forms, with a particular focus on the challenges, opportunities for method optimization and recent advances with respect three main aspects: effective sample size measured by NIR, probe location and method robustness.
Collapse
Affiliation(s)
- Natasha L Velez
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, United States; Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, United States.
| | - James K Drennen
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, United States; Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, United States.
| | - Carl A Anderson
- Duquesne University Graduate School for Pharmaceutical Sciences, Pittsburgh, PA 15282, United States; Duquesne Center for Pharmaceutical Technology, Duquesne University, Pittsburgh, PA 15282, United States.
| |
Collapse
|
9
|
Determination and understanding of lead-lag between in-line NIR tablet press feed frame and off-line NIR tablet measurements. Int J Pharm 2022; 611:121328. [PMID: 34852290 DOI: 10.1016/j.ijpharm.2021.121328] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 11/23/2021] [Accepted: 11/25/2021] [Indexed: 11/21/2022]
Abstract
The influence of different tableting process parameters on lead-lag was studied by collecting in-line near-infrared (NIR) spectra in the filling chamber of the tablet press feed frame and off-line NIR tablet data. Lead-lag is defined as the difference in time and API concentration between the measured in-line feed frame NIR response and the off-line NIR tablet data. Lead-lag results from the product formulation blend undergoing additional mixing after passing the NIR probe inside the feed frame, before being filled into the dies of the tablet press. A design of experiments (DoE) was performed to evaluate the effect of the tableting process factors paddle speed, turret speed, overfill level, paddle speed ratio and feed frame type upon lead-lag. Paddle speed and turret speed were identified as the only tableting parameters affecting lead-lag. Lead-lag decreased with increasing paddle speed or turret speed and became negligible at high paddle speed and high turret speed. Overfill level, paddle speed ratio and feed frame type did not affect lead-lag, suggesting that the amount and the trajectory of the recirculating powder in the feed frame did not significantly vary and hence influence the lead-lag within the examined process factor ranges. Finally, a methodology was developed using the in-line feed frame NIR measurements for the continuous monitoring and control of blend potency and tablet content uniformity. Tablet diversion should start when the in-line feed frame monitored blend potency exceeds the predefined control limits and can discontinue when this blend potency is again within the control limits for a duration equal to the lead-lag time. A combination of continuous blend potency monitoring inside the feed frame and in-process tablet weight control allows real-time tablet content uniformity assurance. Although the findings of this study are restricted to the specific equipment, tableting parameter ranges and product formulation used, the suggested approach for lead-lag determination and continuous tablet content uniformity monitoring can be applied to any rotary tablet press and product formulation.
Collapse
|
10
|
Sierra-Vega NO, González-Rosario RA, Rangel-Gil RS, Romañach RJ, Méndez R. Quantitative analysis of blend uniformity within a Three-Chamber feed frame using simultaneously Raman and Near-Infrared spectroscopy. Int J Pharm 2021; 613:121417. [PMID: 34965466 DOI: 10.1016/j.ijpharm.2021.121417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/14/2021] [Accepted: 12/18/2021] [Indexed: 11/29/2022]
Abstract
This study reports the use of Raman and Near-infrared (NIR) spectroscopy to simultaneously monitor the drug concentration in flowing powder blends within a three-chamber feed frame. The Raman probe was located at the top of the dosing chamber, while the NIR probe was located at the top of the filling chamber. The Raman and NIR spectra were continuously acquired while the powder blends flowed through the feed frame. Calibration models were developed with spectra from a total of five calibration blends ranging in caffeine concentration among 3.50 and 6.50% w/w. These models were optimized to predict three test set blends of 4.00, 5.00, and 6.00% w/w caffeine. The results showed a high predictive ability of the models based on root mean square error of predictions of 0.174 and 0.235% w/w for NIR and Raman spectroscopic models, respectively. Concentration profiles with higher variability were observed for the Raman spectroscopy predictions. An estimate of the mass analyzed by each spectrum showed that a NIR spectrum analyzes approximately 4.5 times the mass analyzed by a Raman spectrum; despite these differences in the mass analyzed, blend uniformity results are equivalent between techniques. Variographic analysis demonstrated that both techniques have significantly low sampling errors for the real-time monitoring process of drug concentration within the feed frame.
Collapse
Affiliation(s)
- Nobel O Sierra-Vega
- Department of Chemical Engineering, University of Puerto Rico at Mayaguez, Puerto Rico 00681, United States.
| | - Rafael A González-Rosario
- Department of Chemical Engineering, University of Puerto Rico at Mayaguez, Puerto Rico 00681, United States
| | - Raúl S Rangel-Gil
- Department of Chemical Engineering, University of Puerto Rico at Mayaguez, Puerto Rico 00681, United States
| | - Rodolfo J Romañach
- Department of Chemistry, University of Puerto Rico at Mayaguez, Puerto Rico 00681, United States
| | - Rafael Méndez
- Department of Chemical Engineering, University of Puerto Rico at Mayaguez, Puerto Rico 00681, United States
| |
Collapse
|
11
|
NIR spectroscopic methods for monitoring blend potency in a feed frame - calibration transfer between offline and inline using a continuum regression filter. Int J Pharm 2021; 614:121363. [PMID: 34954005 DOI: 10.1016/j.ijpharm.2021.121363] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 11/29/2021] [Accepted: 12/05/2021] [Indexed: 11/22/2022]
Abstract
A material sparing method for near-infrared (NIR) calibration was developed using an offline apparatus coupled with a calibration transfer method to enable a partial least squares (PLS) model to monitor the concentration of active pharmaceutical ingredients (API) in the feed frame of a rotary tablet press. The offline apparatus was designed to simulate the powder flow dynamic and NIRS measurement environment of a tablet-press feed frame. A comprehensive experimental design, including calibration and testing, was employed to determine blend inhomogeneity. NIR spectra were collected at both the feed frame (inline) conditions and the simulator (offline) conditions. The simulator conditions were designed to mimic the density and powder flow in the feed frame during the actual tableting process. The offline data were pretreated by an orthogonalization-based calibration transfer algorithm, a continuum regression filter (CR filter), before being subjected to PLS modeling. This study demonstrated: (1) calibration for inline application can be generated using an offline apparatus, and (2) the CR filter, as an innovative calibration transfer method, can generalize the offline method for multiple feed frame conditions.
Collapse
|
12
|
Jakubowska E, Ciepluch N. Blend Segregation in Tablets Manufacturing and Its Effect on Drug Content Uniformity-A Review. Pharmaceutics 2021; 13:pharmaceutics13111909. [PMID: 34834324 PMCID: PMC8620778 DOI: 10.3390/pharmaceutics13111909] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 11/02/2021] [Accepted: 11/08/2021] [Indexed: 11/26/2022] Open
Abstract
Content uniformity (CU) of the active pharmaceutical ingredient is a critical quality attribute of tablets as a dosage form, ensuring reproducible drug potency. Failure to meet the accepted uniformity in the final product may be caused either by suboptimal mixing and insufficient initial blend homogeneity, or may result from further particle segregation during storage, transfer or the compression process itself. This review presents the most relevant powder segregation mechanisms in tablet manufacturing and summarizes the currently available, up-to-date research on segregation and uniformity loss at the various stages of production process—the blend transfer from the bulk container to the tablet press, filling and discharge from the feeding hopper, as well as die filling. Formulation and processing factors affecting the occurrence of segregation and tablets’ CU are reviewed and recommendations for minimizing the risk of content uniformity failure in tablets are considered herein, including the perspective of continuous manufacturing.
Collapse
Affiliation(s)
- Emilia Jakubowska
- Chair and Department of Pharmaceutical Technology, Faculty of Pharmacy, Poznan University of Medical Sciences, 6 Grunwaldzka Street, 60-780 Poznan, Poland
- Correspondence:
| | - Natalia Ciepluch
- Department of Medical Rescue, Chair of Emergency Medicine, Faculty of Health Sciences, Poznan University of Medical Sciences, 7 Rokietnicka Street, 60-806 Poznan, Poland;
| |
Collapse
|
13
|
Mateo-Ortiz D, Villanueva-Lopez V, Muddu SV, Doddridge GD, Alhasson D, Dennis MC. Dry Powder Mixing Is Feasible in Continuous Twin Screw Extruder: Towards Lean Extrusion Process for Oral Solid Dosage Manufacturing. AAPS PharmSciTech 2021; 22:249. [PMID: 34648107 DOI: 10.1208/s12249-021-02148-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 09/22/2021] [Indexed: 11/30/2022] Open
Abstract
Using discrete element method (DEM) modeling and near-infrared (NIR) spectroscopy, the feasibility of powder mixing in the initial pre-melting zones of a twin screw extruder using two independent feeders was studied. Previous work in the pharmaceutical and food industry has focused on mixing when materials are melted or on material homogeneity at the extruder's output. Depending on the formulation, ensuring a fully blended formulation prior to melting may be desired. Experiments were conducted using a Coperion ZSK-18 extruder to evaluate if blend uniformity can be achieved by exploring screw configuration, screw speed, and powder feed rate. As powder exited the extruder and deposited on a conveyor belt, an in-line NIR spectrophotometer measured spectra of material. Chemometric-based models predicted unknown concentrations to evaluate if blend uniformity was achieved. Using the EDEM software, Hertz-Mindlin contact model, and dimensions of the extruder, DEM simulations complemented the experimental work. The DEM computational models provided understanding of mixing patterns inside the extruder at particle scale and helped select the screw configuration before doing experimentation. The simulations showed good axial mixing for all the screw configurations studied, while good cross (radial) mixing was only observed for the screw configuration with 90-degree kneading elements. Therefore, the screw configuration with two 90-degree kneading elements was chosen for the experimental study. The RTD profiles when using a screw configuration with only conveying screw elements are comparable to a plug flow reactor (PFR), while the profiles when using kneading elements are more comparable to an ideal continuous stirred tank reactor (CSTR). For the screw configuration with 90 degrees kneading elements, the mean residence time (MRT) decreases with an increase in the screw speed. Experimental NIR spectra showed that concentrations can be predicted with an error of 2%. It was demonstrated that the twin screw extruder can provide proper dry powder mixing of two powder feed streams based on a unit dose scale, enabling continuous powder mixing prior to the melting zone in the extruder for the formulation studied with a cohesive API. This setup may also work for other types of formulations. These studies can help in developing lean hot melt as well as wet extrusion/granulation processes using twin screw extruders for the continuous manufacturing of oral solid dosage products.
Collapse
|
14
|
Zimmermann M, Thommes M. Residence time and mixing capacity of a rotary tablet press feed frame. Drug Dev Ind Pharm 2021; 47:790-798. [PMID: 34042546 DOI: 10.1080/03639045.2021.1934871] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
PURPOSE Most rotary tablet presses contain a feed frame to provide a continuous powder flow and to feed powder into the dies. The wide residence time distribution (RTD) of these feed frames is problematic, because it negatively affects material traceability in continuous manufacturing. In a rotary tablet press, different machine settings influence the RTD, which is characterized by the mean and the width of the distribution. This study focused on the effects of the rotational speed of the feed frame paddles and the rotary tablet press throughput on the RTD. METHODS An in-line UV/Vis measurement method was developed for determining the RTD in the feed frame. A model based on a plug flow and a continuous stirred tank reactor was adapted to model the experimentally determined RTDs. Finally, the mixing capacity of a feed frame was evaluated and correlated with a model parameter of the RTD. RESULTS Overall, the developed UV/Vis measurement method was suitable and could be used to obtain process information regarding content uniformity in real time. The experimentally-determined RTDs were described well by fitting an inverse mixing and a transport time. In addition, a correlation between the location and the shape of measured RTDs and tablet press throughput was found. In contrast, rotational feed frame paddle speed did not affect the RTDs. Split-feeding experiments indicated the mixing capacity of the rotary tablet press feed frame. CONCLUSION The inverse mixing time can be used as an initial indicator for estimating the mixing capacity.
Collapse
Affiliation(s)
- Maren Zimmermann
- Laboratory of Solids Process Engineering, Department of Biochemical and Chemical Engineering, TU Dortmund University, Dortmund, Germany
| | - Markus Thommes
- Laboratory of Solids Process Engineering, Department of Biochemical and Chemical Engineering, TU Dortmund University, Dortmund, Germany
| |
Collapse
|
15
|
Román-Ospino AD, Baranwal Y, Li J, Vargas J, Igne B, Bate S, Brouckaert D, Chauchard F, Hausner D, Ramachandran R, Singh R, Muzzio FJ. Sampling optimization for blend monitoring of a low dose formulation in a tablet press feed frame using spatially resolved near-infrared spectroscopy. Int J Pharm 2021; 602:120594. [PMID: 33857586 DOI: 10.1016/j.ijpharm.2021.120594] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 03/23/2021] [Accepted: 04/07/2021] [Indexed: 10/21/2022]
Abstract
In-line measurements of low dose blends in the feed frame of a tablet press were performed for API concentration levels as low as 0.10% w/w. The proposed methodology utilizes the advanced sampling capabilities of a Spatially Resolved Near-Infrared (SR-NIR) probe to develop Partial Least-Squares calibration models. The fast acquisition speed of multipoint spectra allowed the evaluation of different numbers of co-adds and feed frame paddle speeds to establish the optimum conditions of data collection to predict low potency blends. The interaction of the feed frame paddles with the SR-NIR probe was captured with high resolution and allowed the implementation of a spectral data selection criterion to remove the effect of the paddles from the calibration and testing process. The method demonstrated accuracy and robustness when predicting drug concentrations across different feed frame paddle speeds.
Collapse
Affiliation(s)
- Andrés D Román-Ospino
- Engineering Research Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, United States
| | - Yukteshwar Baranwal
- Engineering Research Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, United States
| | - Jingzhe Li
- Engineering Research Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, United States
| | - Jenny Vargas
- GlaxoSmithKline (GSK), Collegeville, PA 19426, United States
| | - Benoît Igne
- GlaxoSmithKline (GSK), Collegeville, PA 19426, United States
| | - Simon Bate
- GlaxoSmithKline (GSK), Collegeville, PA 19426, United States
| | | | | | - Douglas Hausner
- Engineering Research Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, United States
| | - Rohit Ramachandran
- Engineering Research Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, United States
| | - Ravendra Singh
- Engineering Research Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, United States
| | - Fernando J Muzzio
- Engineering Research Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, United States.
| |
Collapse
|
16
|
Zhong WZ, Zakhvatayeva A, Zhang L, Wu CY. Powder flow during linear and rotary die filling. Int J Pharm 2021; 602:120654. [PMID: 33915183 DOI: 10.1016/j.ijpharm.2021.120654] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Revised: 04/03/2021] [Accepted: 04/23/2021] [Indexed: 11/16/2022]
Abstract
In the pharmaceutical industry, linear die filling is widely employed in R&D, while rotary die filling is very common in commercial production. It is not clear if powder die filling behaviour in a linear die filling system is representative of the flow performance in a rotary tablet press. In this study, a linear die filling system and a rotary die filling system were used to examine flow behaviours of both poor-flowing and free-flowing powders. It was found that the performance of poor-flowing powder in the linear die filling system is slightly better than that in the rotary die filling system, while the performance of free-flowing powders in the linear die filling system is similar to that in the rotary die filling system. Hence, it is suitable to use the linear die filling system to estimate the flow behaviour during rotary die filling with free-flowing powders, but caution needs to be taken when poor-flowing powders are used.
Collapse
Affiliation(s)
- Wen-Zhen Zhong
- School of Mechanical Engineering, University of Jinan, Shandong 250022, China.
| | | | - Ling Zhang
- Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, UK
| | - Chuan-Yu Wu
- Department of Chemical and Process Engineering, University of Surrey, Guildford GU2 7XH, UK
| |
Collapse
|
17
|
Hetrick EM, Shi Z, Harms ZD, Myers DP. Sample Mass Estimate for the Use of Near-Infrared and Raman Spectroscopy to Monitor Content Uniformity in a Tablet Press Feed Frame of a Drug Product Continuous Manufacturing Process. APPLIED SPECTROSCOPY 2021; 75:216-224. [PMID: 32721168 DOI: 10.1177/0003702820950318] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Recently, feed frame-based process analytical technology measurements used to assure product quality during continuous manufacturing processes have received significant attention. These measurements are able to accurately determine uniformity of the powder blend before compression, and in these applications, it is necessary to understand the interrogated sample volume per measurement. This understanding ensures that the blend measurement can be indicative of the uniformity of the final dosage form. A scientifically sound approach is proposed here to estimate sample mass for a continuous manufacturing process that utilizes either near infrared or Raman spectroscopy. A wide range of commercially available probes with varying spot diameters are considered. By comparing near infrared and Raman spectroscopy, an optimal range of probe spot diameters was identified in order to reach an estimated sample mass between 50 and 500 mg for pharmaceutical blends per measurement, which is equivalent to common tablet weight ranges for solid oral dosage forms currently on the market.
Collapse
Affiliation(s)
- Evan M Hetrick
- Lilly Research Laboratories, Eli Lilly & Co., Indianapolis, IN, USA
| | - Zhenqi Shi
- Lilly Research Laboratories, Eli Lilly & Co., Indianapolis, IN, USA
| | - Zachary D Harms
- Lilly Research Laboratories, Eli Lilly & Co., Indianapolis, IN, USA
| | - David P Myers
- Lilly Research Laboratories, Eli Lilly & Co., Indianapolis, IN, USA
| |
Collapse
|
18
|
Tanimura S, Singh R, Román-Ospino AD, Ierapetritou M. Residence time distribution modelling and in line monitoring of drug concentration in a tablet press feed frame containing dead zones. Int J Pharm 2020; 592:120048. [PMID: 33161037 DOI: 10.1016/j.ijpharm.2020.120048] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 10/15/2020] [Accepted: 11/01/2020] [Indexed: 01/08/2023]
Abstract
The presence of a 'significant dead zone' in any continuous manufacturing equipment may affect the product quality and need to be investigated systematically. Dead zone will affect the residence time distribution (RTD) of continuous manufacturing and thus the mixing and product quality. Tablet press (feed frame) is one of unit operations that directly influence the critical quality attributes (CQA's). However, currently no systematic methods and tools are available to characterize and model the feed frame dead zone. In this manuscript, the RTD of the tablet press feed frame containing dead zone is investigated. Step-change experiments revealed that the feed frame could be expressed as a traditional continuous stirred tank model. The volume fractions of the dead zones are determined experimentally as well as using RTD model. In addition, an in-line NIR method for drug concentration monitoring inside the feed frame is also developed. The developed NIR calibration model enables to monitor the drug concentration precisely and detect the variation immediately with the probe positioned right above the left paddle. It is also found that the feed frame paddle speed slightly affects the predictive accuracy of NIR, while the die disc speed has no significant effect.
Collapse
Affiliation(s)
- Shinji Tanimura
- CMC R&D Center, Kyowa Kirin Co., Ltd., 1188 Shimotogari, Nagaizumi-cho, Sunto-gun, Shizuoka 411-8731 Japan
| | - Ravendra Singh
- Engineering Research Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, USA.
| | - Andrés D Román-Ospino
- Engineering Research Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, USA
| | - Marianthi Ierapetritou
- Department of Chemical and Biomolecular Engineering, University of Delaware, DE 19716, USA.
| |
Collapse
|
19
|
Flow behaviour of pharmaceutical powders during rotary die filling with a paddle feeder. Int J Pharm 2020; 585:119547. [DOI: 10.1016/j.ijpharm.2020.119547] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 06/11/2020] [Accepted: 06/12/2020] [Indexed: 11/23/2022]
|
20
|
In-line monitoring of low drug concentration of flowing powders in a new sampler device. Int J Pharm 2020; 583:119358. [DOI: 10.1016/j.ijpharm.2020.119358] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 04/15/2020] [Accepted: 04/19/2020] [Indexed: 01/18/2023]
|
21
|
Muñoz SG, Torres EH. Supervised Extended Iterative Optimization Technology for Estimation of Powder Compositions in Pharmaceutical Applications: Method and Lifecycle Management. Ind Eng Chem Res 2020. [DOI: 10.1021/acs.iecr.0c01385] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
22
|
Impact of Particle and Equipment Properties on Residence Time Distribution of Pharmaceutical Excipients in Rotary Tablet Presses. Pharmaceutics 2020; 12:pharmaceutics12030283. [PMID: 32245219 PMCID: PMC7151020 DOI: 10.3390/pharmaceutics12030283] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 03/18/2020] [Accepted: 03/19/2020] [Indexed: 11/17/2022] Open
Abstract
Paddle feeders are devices commonly used in rotary tablet presses to facilitate constant and efficient die filling. Adversely, the shear stress applied by the rotating paddles is known to affect the bulk properties of the processed powder dependent on the residence time. This study focuses on the residence time distribution (RTD) of two commonly applied excipients (microcrystalline cellulose, MCC; dicalcium phosphate, DCP), which exhibit different flow properties inside rotary tablet presses. To realistically depict the powder flow inside rotary tablet presses, custom-made tracer powder was developed. The applied method was proven to be appropriate as the tracer and bulk powder showed comparable properties. The RTDs of both materials were examined in two differently scaled rotary tablet presses and the influence of process parameters was determined. To analyze RTDs independent of the mass flow, the normalized variance was used to quantify intermixing. Substantial differences between both materials and tablet presses were found. Broader RTDs were measured for the poorer flowing MCC as well as for the production scale press. The obtained results can be used to improve the general understanding of powder flow inside rotary tablet presses and amplify scale-up and continuous production process development.
Collapse
|
23
|
The Challenge of Die Filling in Rotary Presses-A Systematic Study of Material Properties and Process Parameters. Pharmaceutics 2020; 12:pharmaceutics12030248. [PMID: 32164230 PMCID: PMC7150958 DOI: 10.3390/pharmaceutics12030248] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 03/03/2020] [Accepted: 03/05/2020] [Indexed: 11/20/2022] Open
Abstract
For the efficient and safe production of pharmaceutical tablets, a deep process understanding is of high importance. An essential process step during tableting is the die filling, as it is responsible for a consistent tablet weight and drug content. Furthermore, it affects the results of subsequent process steps, compaction and ejection, and thus critical quality attributes. This study focuses on understanding the influences of process parameters and material properties on die filling on a rotary tablet press. By the systematic variation in process parameters as the turret and paddle speeds as well as the fill and dosing depths, five formulations with differing properties are processed. Analysis of the normalized tablet weight, called filling yield, revealed different limitation mechanisms of the filling process, i.e., incomplete filled dies for certain parameter settings. Kinetic limitations occur due to a short residence time under the feed frame (filling time) caused by high turret speeds, which additionally induce high tablet weight variation coefficients. Characteristic maximum turret speeds at certain paddle speeds can be found to still achieve complete filling. At low turret speeds, densification of the powder inside the dies takes place, induced by two mechanisms: either high paddle speeds or high overfill ratios, or a combination of both. The challenge to fill the dies completely as well as avoid densification is dependent on material properties as the flowability. The mass discharge rate from an orifice was found to be in a linear correlation to the filling results of different formulations below complete filling.
Collapse
|
24
|
Hildebrandt C, Gopireddy SR, Scherließ R, Urbanetz NA. A DEM approach to assess the influence of the paddle wheel shape on force feeding during pharmaceutical tableting. ADV POWDER TECHNOL 2020. [DOI: 10.1016/j.apt.2019.11.030] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
25
|
Alvarado-Hernández BB, Sierra-Vega NO, Martínez-Cartagena P, Hormaza M, Méndez R, Romañach RJ. A sampling system for flowing powders based on the theory of sampling. Int J Pharm 2019; 574:118874. [PMID: 31837408 DOI: 10.1016/j.ijpharm.2019.118874] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 11/10/2019] [Accepted: 11/12/2019] [Indexed: 12/16/2022]
Abstract
An innovative chute and stream sampler system for flowing powders has been developed and tested. The system is designed for representative sampling based on the principles of the Theory of Sampling (TOS). The sampling system was used in combination with near infrared (NIR) spectroscopy to determine the drug concentration of flowing powders. The system is comprised of three parts: a chute, a stream sampler and a sample collection port. The NIR spectra were obtained at the chute, before entering the sampler, and as the powder flowed through the stream sampler. Samples were also collected from the sample collection port to be analyzed using an ultraviolet-visible (UV-Vis) reference method to determine drug content. A total of eight pharmaceutical powder blends, ranging in concentration from 10.5(%w/w) to 19.5(%w/w) of caffeine, were used to test the sampling system. Materials were characterized before blends were made to provide information on flow properties. The throughput of the system was between 30 and 35 kg/h based on the flow properties of the blend. Drug concentration was effectively determined at the chute and stream sampler. The NIR calibration models showed low root mean squared errors of prediction, 0.65(%w/w) and 0.51(%w/w), for the chute and stream sampler respectively. The NIR calibration models also showed low bias values -0.36(%w/w) at the chute and 0.057(%w/w) at the stream sampler. Significant agreement was obtained between the results from the nondestructive NIR versus the destructive UV-Vis method. Variographic analysis was performed to estimate the analytical and sampling errors when determining the drug concentration at the chute and stream sampler respectively. The variographic analysis showed low analytical errors, 0.103(%w/w)2 and 0.181(%w/w)2 at the chute and stream sampler respectively. The analysis also showed that the minimum practical error (MPE) was around 0.2(%w/w)2 at both chute and stream sampler.
Collapse
Affiliation(s)
| | - Nobel O Sierra-Vega
- Department of Chemical Engineering, University of Puerto Rico at Mayaguez, Puerto Rico
| | - Pedro Martínez-Cartagena
- Department of Chemistry, University of Puerto Rico at Mayaguez, Call Box 9000, Mayaguez 00680, Puerto Rico
| | - Manuel Hormaza
- IBS Caribe INC., P.O. Box 8849, San Juan PR 00910, Puerto Rico
| | - Rafael Méndez
- Department of Chemical Engineering, University of Puerto Rico at Mayaguez, Puerto Rico
| | - Rodolfo J Romañach
- Department of Chemistry, University of Puerto Rico at Mayaguez, Call Box 9000, Mayaguez 00680, Puerto Rico.
| |
Collapse
|
26
|
Characterization of NIR interfaces for the feeding and in-line monitoring of a continuous granulation process. Int J Pharm 2019; 574:118848. [PMID: 31812798 DOI: 10.1016/j.ijpharm.2019.118848] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 10/28/2019] [Accepted: 11/04/2019] [Indexed: 11/23/2022]
Abstract
This work describes the characterization of three NIR interfaces intended to monitor a continuous granulation process. Two interfaces (i.e. a barrel interface and a rotating paddle interface) were evaluated to monitor the API concentration at the entrance of the granulator, and a third interface (i.e. an outlet interface), was evaluated to examine the quality of the resulting outlet granules. The barrel interface provided an assessment of the API concentration during the feeding process by scanning the material conveyed by the screws of the loss-in-weight feeder. The rotating paddle interface analyzed discrete amounts of powder upon exiting the feeder via the accumulation of material on the paddles. Partial Least Squares (PLS) calibration models were developed using the same powder blends for the two inlet interfaces and using the outlet granules for the outlet interface. Five independent batches were used to evaluate the prediction performance of each inlet calibration model. The outlet interface produced the lowest error of prediction due to the homogeneity of the granules. The barrel interface produced lower errors of prediction than the rotating paddle interface. However, powder density affected only the barrel interface, producing deviations in the predicted values. Therefore, powder density is a factor that should be considered in the calibration sample design for spectroscopic measurements when using this type of interface. A variographic analysis demonstrated that the continuous 1-dimensional motion in the barrel and outlet interfaces produced representative measurements of each batch during calibration and test experiments, generating a low minimum practical error (MPE).
Collapse
|
27
|
Sierra-Vega NO, Romañach RJ, Méndez R. Feed frame: The last processing step before the tablet compaction in pharmaceutical manufacturing. Int J Pharm 2019; 572:118728. [PMID: 31682965 DOI: 10.1016/j.ijpharm.2019.118728] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 09/19/2019] [Accepted: 09/21/2019] [Indexed: 10/25/2022]
Abstract
The feed frame is a force-feeding device used in the die filling process. The die filling process is crucial within pharmaceutical manufacturing to guarantee the critical quality attributes of the tablets. In recent years, interest in this unit has increased because it can affect the properties of the powder blend and tablets, and because of the success in real time monitoring of powder blend uniformity potential for Process Analytical Technology as described in this review. The review focuses on the recent advances in understanding the powder flow behavior inside the feed frame and how the residence time distribution of the powder within the feed frame is affected by the operating conditions and design parameters. Furthermore, this review also highlights the effect of the paddle wheel design and feed frame process parameters on the tablet weight, the principal variable for measuring die filling performance.
Collapse
Affiliation(s)
- Nobel O Sierra-Vega
- Department of Chemical Engineering, University of Puerto Rico at Mayaguez, PR 00681, United States
| | - Rodolfo J Romañach
- Department of Chemistry, University of Puerto Rico at Mayaguez, PR 00681 United States
| | - Rafael Méndez
- Department of Chemical Engineering, University of Puerto Rico at Mayaguez, PR 00681, United States.
| |
Collapse
|
28
|
Li Y, Anderson CA, Drennen JK, Airiau C, Igne B. Development of an In-Line Near-Infrared Method for Blend Content Uniformity Assessment in a Tablet Feed Frame. APPLIED SPECTROSCOPY 2019; 73:1028-1040. [PMID: 30990067 DOI: 10.1177/0003702819842189] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Process analytical technology (PAT) has shown great potential for in-line tableting process monitoring. The study focuses on the development and validation of an in-line near-infrared (NIR) spectroscopic method for the determination of content uniformity of blends in a tablet feed frame. An in-line NIR method was developed after careful evaluation of the impact of potential experimental factors on the robustness and model accuracy and precision. The NIR method was validated according to the principles outlined in International Conference on Harmonization-Q2 for validation of analytical procedures and was demonstrated to be suitable for monitoring blend content for the formulation under evaluation. Reliable measurements of blend homogeneity rely on representative sampling. To reach the appropriate scale of scrutiny for a unit dose, the study assessed factors that influence the effective sample size measured by NIR. Spectral averaging, integration time, and feed frame paddle wheel speed were found to influence the effective sample size measured by the NIR probe. The effective sampling size was also estimated by comparing the distribution of predicted values with the reference values. The development of a robust, in-line PAT method was facilitated by thorough understanding of the sensitivity of PAT sensors to factors affecting pharmaceutical processes and products.
Collapse
Affiliation(s)
- Yi Li
- Duquesne University, Graduate School of Pharmaceutical Sciences, Pittsburgh, PA, USA
| | - Carl A Anderson
- Duquesne University, Graduate School of Pharmaceutical Sciences, Pittsburgh, PA, USA
| | - James K Drennen
- Duquesne University, Graduate School of Pharmaceutical Sciences, Pittsburgh, PA, USA
| | - Christian Airiau
- GlaxoSmithKline, Analytical Sciences and Development, Collegeville, PA, USA
| | - Benoît Igne
- GlaxoSmithKline, Analytical Sciences and Development, Collegeville, PA, USA
| |
Collapse
|
29
|
Razuc M, Grafia A, Gallo L, Ramírez-Rigo MV, Romañach RJ. Near-infrared spectroscopic applications in pharmaceutical particle technology. Drug Dev Ind Pharm 2019; 45:1565-1589. [DOI: 10.1080/03639045.2019.1641510] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- M. Razuc
- Instituto de Química del Sur (INQUISUR), Universidad Nacional del Sur (UNS)-CONICET, Bahía Blanca, Argentina
- Departamento de Biología, Bioquímica y Farmacia, Universidad Nacional del Sur (UNS), Bahía Blanca, Argentina
| | - A. Grafia
- Planta Piloto de Ingeniería Química (PLAPIQUI), Universidad Nacional del Sur (UNS)- CONICET, Bahía Blanca, Argentina
| | - L. Gallo
- Departamento de Biología, Bioquímica y Farmacia, Universidad Nacional del Sur (UNS), Bahía Blanca, Argentina
- Planta Piloto de Ingeniería Química (PLAPIQUI), Universidad Nacional del Sur (UNS)- CONICET, Bahía Blanca, Argentina
| | - M. V. Ramírez-Rigo
- Departamento de Biología, Bioquímica y Farmacia, Universidad Nacional del Sur (UNS), Bahía Blanca, Argentina
- Planta Piloto de Ingeniería Química (PLAPIQUI), Universidad Nacional del Sur (UNS)- CONICET, Bahía Blanca, Argentina
| | - R. J. Romañach
- Department of Chemistry, Center for Structured Organic Particulate Systems, University of Puerto Rico – Mayagüez, Mayagüez, Puerto Rico
| |
Collapse
|
30
|
Dühlmeyer K, Özcoban H, Leopold C. Inline monitoring of the powder filling level within a rotary tablet press feed frame. POWDER TECHNOL 2019. [DOI: 10.1016/j.powtec.2019.04.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
31
|
Harms ZD, Shi Z, Kulkarni RA, Myers DP. Characterization of Near-Infrared and Raman Spectroscopy for In-Line Monitoring of a Low-Drug Load Formulation in a Continuous Manufacturing Process. Anal Chem 2019; 91:8045-8053. [DOI: 10.1021/acs.analchem.8b05002] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Zachary D. Harms
- Small Molecule Design and Development, Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | - Zhenqi Shi
- Small Molecule Design and Development, Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | - Rajesh A. Kulkarni
- Small Molecule Design and Development, Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | - David P. Myers
- Small Molecule Design and Development, Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| |
Collapse
|
32
|
Variographic analysis: A new methodology for quality assurance of pharmaceutical blending processes. Comput Chem Eng 2019. [DOI: 10.1016/j.compchemeng.2019.02.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
33
|
Dalvi H, Langlet A, Colbert MJ, Cournoyer A, Guay JM, Abatzoglou N, Gosselin R. In-line monitoring of Ibuprofen during and after tablet compression using near-infrared spectroscopy. Talanta 2019; 195:87-96. [DOI: 10.1016/j.talanta.2018.11.034] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 11/08/2018] [Accepted: 11/12/2018] [Indexed: 11/16/2022]
|
34
|
Burcham CL, Florence AJ, Johnson MD. Continuous Manufacturing in Pharmaceutical Process Development and Manufacturing. Annu Rev Chem Biomol Eng 2019; 9:253-281. [PMID: 29879381 DOI: 10.1146/annurev-chembioeng-060817-084355] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The pharmaceutical industry has found new applications for the use of continuous processing for the manufacture of new therapies currently in development. The transformation has been encouraged by regulatory bodies as well as driven by cost reduction, decreased development cycles, access to new chemistries not practical in batch, improved safety, flexible manufacturing platforms, and improved product quality assurance. The transformation from batch to continuous manufacturing processing is the focus of this review. The review is limited to small, chemically synthesized organic molecules and encompasses the manufacture of both active pharmaceutical ingredients (APIs) and the subsequent drug product. Continuous drug product is currently used in approved processes. A few examples of production of APIs under current good manufacturing practice conditions using continuous processing steps have been published in the past five years, but they are lagging behind continuous drug product with respect to regulatory filings.
Collapse
Affiliation(s)
- Christopher L Burcham
- Small Molecule Design and Development, Eli Lilly and Company, Lilly Research Laboratory, Indianapolis, Indiana 48525, USA; ,
| | - Alastair J Florence
- EPSRC Future CMAC Hub, Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, G11XQ United Kingdom;
| | - Martin D Johnson
- Small Molecule Design and Development, Eli Lilly and Company, Lilly Research Laboratory, Indianapolis, Indiana 48525, USA; ,
| |
Collapse
|
35
|
Investigation of powder flow within a pharmaceutical tablet press force feeder – A DEM approach. POWDER TECHNOL 2019. [DOI: 10.1016/j.powtec.2019.01.040] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
36
|
Sierra-Vega NO, Román-Ospino A, Scicolone J, Muzzio FJ, Romañach RJ, Méndez R. Assessment of blend uniformity in a continuous tablet manufacturing process. Int J Pharm 2019; 560:322-333. [PMID: 30763679 DOI: 10.1016/j.ijpharm.2019.01.073] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 01/25/2019] [Accepted: 01/31/2019] [Indexed: 12/20/2022]
Abstract
Blend uniformity was monitored throughout a continuous manufacturing (CM) process by near infrared (NIR) spectroscopic measurements of flowing blends and compared to the drug concentration in the tablets. The NIR spectra were obtained through the chute after the blender and within the feed frame, while transmission spectra were obtained for the tablets. The CM process was performed with semi-fine acetaminophen blends at 10.0% (w/w). The blender was operated at 250 RPM, for best performance, and 106 and 495 rpm where a lower mixing efficiency was expected. The variation in blender RPM increased the variation in drug concentration at the chute but not at the feed frame. Statistical results show that the drug concentration of tablets can be predicted, with great accuracy, from blends within the feed frame. This study demonstrated a mixing effect within the feed frame, which contribute to a 60% decrease in the relative standard deviation of the drug concentration, when compared to the chute. Variographic analysis showed that the minimum sampling and analytical error was five times less in the feed frame than the chute. This study demonstrates that the feed frame is an ideal location for monitoring the drug concentration of powder blends for CM processes.
Collapse
Affiliation(s)
- Nobel O Sierra-Vega
- Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical Engineering, University of Puerto Rico at Mayaguez, PR 00681, United States
| | - Andrés Román-Ospino
- Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers University, New Jersey, Piscataway 08854, United States
| | - James Scicolone
- Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers University, New Jersey, Piscataway 08854, United States
| | - Fernando J Muzzio
- Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical and Biochemical Engineering, Rutgers University, New Jersey, Piscataway 08854, United States
| | - Rodolfo J Romañach
- Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemistry, University of Puerto Rico at Mayaguez, PR 00681, United States
| | - Rafael Méndez
- Center for Structured Organic Particulate Systems (C-SOPS), Department of Chemical Engineering, University of Puerto Rico at Mayaguez, PR 00681, United States.
| |
Collapse
|
37
|
Development of near infrared spectroscopic calibration models for in-line determination of low drug concentration, bulk density, and relative specific void volume within a feed frame. J Pharm Biomed Anal 2019; 164:211-222. [DOI: 10.1016/j.jpba.2018.10.046] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Revised: 10/24/2018] [Accepted: 10/25/2018] [Indexed: 11/24/2022]
|
38
|
Shi Z, Hermiller J, Muñoz SG. Estimation of mass-based composition in powder mixtures using Extended Iterative Optimization Technology (EIOT). AIChE J 2018. [DOI: 10.1002/aic.16417] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Zhenqi Shi
- Small Molecule Design & Development; Lilly Research Laboratories; Indianapolis IN, 46285
| | - James Hermiller
- Small Molecule Design & Development; Lilly Research Laboratories; Indianapolis IN, 46285
| | - Salvador García Muñoz
- Small Molecule Design & Development; Lilly Research Laboratories; Indianapolis IN, 46285
| |
Collapse
|
39
|
Goh HP, Sia Heng PW, Liew CV. The Effects of Feed Frame Parameters and Turret Speed on Mini-Tablet Compression. J Pharm Sci 2018; 108:1161-1171. [PMID: 30237030 DOI: 10.1016/j.xphs.2018.09.005] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Revised: 08/22/2018] [Accepted: 09/05/2018] [Indexed: 10/28/2022]
Abstract
Die filling is a critical process step during tablet production as it defines the tablet weight. Achieving die fill consistency during production of mini-tablets, tablets with diameters ≤6 mm, is considerably more challenging. Although die filling in rotary presses had been studied in relation to the feed paddle design, paddle speed, and turret speed, it is unclear how these process variables could impact mini-tablet production and product properties. In this study, 1.8 and 3 mm mini-tablets were prepared using a rotary press with multiple-tip tooling using different process configurations. Mini-tablet weight variation within and across compaction cycles were determined using data from compression roller displacement and mini-tablet weight. Higher die fill densities were achieved with a flat feed wheel paddle and high paddle speed. This was attributed to better granule fluidization in the feed frame, which also increased the intercycle weight variation and reduced tensile strength. The turret speed did not impact mini-tablet properties significantly. Granule overlubrication in the feed frame potentially reduced mini-tablet tensile strength during compaction. The number of paddle passes in the die fill region was correlated to mini-tablet die fill performance. Findings from this study could provide better insights into the relationship between process variables and mini-tablet product quality.
Collapse
Affiliation(s)
- Hui Ping Goh
- Department of Pharmacy, GEA-NUS Pharmaceutical Processing Research Laboratory, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore
| | - Paul Wan Sia Heng
- Department of Pharmacy, GEA-NUS Pharmaceutical Processing Research Laboratory, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore
| | - Celine Valeria Liew
- Department of Pharmacy, GEA-NUS Pharmaceutical Processing Research Laboratory, National University of Singapore, 18 Science Drive 4, Singapore 117543, Singapore.
| |
Collapse
|
40
|
Dühlmeyer KP, Özcoban H, Leopold CS. A novel method for determination of the filling level in the feed frame of a rotary tablet press. Drug Dev Ind Pharm 2018; 44:1744-1751. [PMID: 29961339 DOI: 10.1080/03639045.2018.1492609] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
AIM The aim of this study was to investigate whether the filling level within the feed frame of a rotary tablet press can be quantified by laser triangulation combined with the angle recognition of one paddle wheel via rotary encoder. SIGNIFICANCE Rotary tablet press feed frames are supposed to assure a uniform die filling and, thus, to guarantee the weight and content uniformity of the resulting tablets. Therefore, a constant bulk availability and flow within the feed frame is crucial and has to be ensured by the feed frame design and the operating conditions. So far, there is no instrument available to monitor the bulk filling level or the bulk distribution within feed frames. METHODS Calcium phosphate dihydrate was used as model powder. The powder surface level was determined via laser triangulation and the angle position of the paddle wheel was monitored via incremental rotary encoder. The data of both parameters was acquired synchronously and evaluated by in-house written software. RESULTS Different powder masses led to significantly different filling level signals. The experiments showed a high reproducibility of the determined filling levels. Furthermore, an influence of the rotational speed on the powder distribution was observed. CONCLUSIONS The developed instrument may be used for quantification of the volumetric filling level within rotary tablet press feed frames. It may either be used to better understand the powder behavior within feed frames or for improvement of the die filling process by implementing the device into a feedback loop.
Collapse
Affiliation(s)
- K P Dühlmeyer
- a Division of Pharmaceutical Technology, Department of Chemistry , University of Hamburg , Hamburg , Germany
| | - H Özcoban
- b Fette Compacting GmbH , Schwarzenbek , Germany
| | - C S Leopold
- a Division of Pharmaceutical Technology, Department of Chemistry , University of Hamburg , Hamburg , Germany
| |
Collapse
|
41
|
Li Y, Anderson CA, Drennen JK, Airiau C, Igne B. Method Development and Validation of an Inline Process Analytical Technology Method for Blend Monitoring in the Tablet Feed Frame Using Raman Spectroscopy. Anal Chem 2018; 90:8436-8444. [DOI: 10.1021/acs.analchem.8b01009] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Yi Li
- Duquesne University, Graduate School of Pharmaceutical Sciences, Pittsburgh, Pennsylvania 15282, United States
| | - Carl A. Anderson
- Duquesne University, Graduate School of Pharmaceutical Sciences, Pittsburgh, Pennsylvania 15282, United States
| | - James K. Drennen
- Duquesne University, Graduate School of Pharmaceutical Sciences, Pittsburgh, Pennsylvania 15282, United States
| | - Christian Airiau
- GlaxoSmithKline, Analytical Sciences and Development, King of Prussia, Pennsylvania 19406, United States
| | - Benoît Igne
- GlaxoSmithKline, Analytical Sciences and Development, King of Prussia, Pennsylvania 19406, United States
| |
Collapse
|
42
|
Sierra-Vega NO, Sánchez-Paternina A, Maldonado N, Cárdenas V, Romañach RJ, Méndez R. In line monitoring of the powder flow behavior and drug content in a Fette 3090 feed frame at different operating conditions using Near Infrared spectroscopy. J Pharm Biomed Anal 2018; 154:384-396. [DOI: 10.1016/j.jpba.2018.03.017] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 03/06/2018] [Accepted: 03/09/2018] [Indexed: 10/17/2022]
|
43
|
De Leersnyder F, Peeters E, Djalabi H, Vanhoorne V, Van Snick B, Hong K, Hammond S, Liu AY, Ziemons E, Vervaet C, De Beer T. Development and validation of an in-line NIR spectroscopic method for continuous blend potency determination in the feed frame of a tablet press. J Pharm Biomed Anal 2018; 151:274-283. [DOI: 10.1016/j.jpba.2018.01.032] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 01/16/2018] [Accepted: 01/17/2018] [Indexed: 10/18/2022]
|
44
|
Zeng X, Xiong X, Yang H, Tang B, Du Q, Hou Q, Suo Z, Li H. Quantitative Monitoring the Anti-Solvent Crystallization and Storage Process for Nandrolone by Near-Infrared Spectroscopy. J Pharm Sci 2018; 107:1928-1936. [PMID: 29339135 DOI: 10.1016/j.xphs.2018.01.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Revised: 12/08/2017] [Accepted: 01/08/2018] [Indexed: 10/18/2022]
Abstract
A novel hydrate (SH2O) of nandrolone was prepared by anti-solvent methods. The crystallization processes with 2 schemes (A and B) were monitored by in-line near-infrared (NIR) spectroscopy. The amounts of SH2O in powder samples obtained by the anti-solvent crystallization and storage process were quantified by NIR combined with chemometrics methods. In-line NIR spectra from 4500 to 8000 cm-1 were chosen to capture physicochemical changes during the whole crystallization process. The combination of the principal component results with offline characterization (scanning electron microscopy, powder X-ray diffraction, NIR) data showed that both schemes yielded high purity SH2O products, but the crystallization speed of scheme B was significantly accelerated. It was demonstrated that in-line NIR spectroscopy combined with principal component analysis can be very useful to monitor in real time and control the anti-solvent crystallization process. Moreover, the solubility and the solid-state transformation of nandrolone under different storage conditions were investigated. The apparent solubility of SH2O was 2.19-2.44 times of Form I, and SH2O was relatively stable when stored at a high relative humidity and temperature below 25°C.
Collapse
Affiliation(s)
- Xia Zeng
- Department of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Xinnuo Xiong
- Department of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Hongqin Yang
- Department of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Bin Tang
- Department of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Qiaohong Du
- Department of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Quan Hou
- Department of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Zili Suo
- Department of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Hui Li
- Department of Chemical Engineering, Sichuan University, Chengdu 610065, China.
| |
Collapse
|
45
|
García-Muñoz S, Butterbaugh A, Leavesley I, Manley LF, Slade D, Bermingham S. A flowsheet model for the development of a continuous process for pharmaceutical tablets: An industrial perspective. AIChE J 2017. [DOI: 10.1002/aic.15967] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
| | | | | | | | - David Slade
- Process Systems Enterprise Ltd; 26-28 Hammersmith Grove, London W6 7HA U.K
| | - Sean Bermingham
- Process Systems Enterprise Ltd; 26-28 Hammersmith Grove, London W6 7HA U.K
| |
Collapse
|
46
|
Hetrick EM, Shi Z, Barnes LE, Garrett AW, Rupard RG, Kramer TT, Cooper TM, Myers DP, Castle BC. Development of Near Infrared Spectroscopy-based Process Monitoring Methodology for Pharmaceutical Continuous Manufacturing Using an Offline Calibration Approach. Anal Chem 2017; 89:9175-9183. [DOI: 10.1021/acs.analchem.7b01907] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Evan M. Hetrick
- Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | - Zhenqi Shi
- Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | - Lukas E. Barnes
- Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | - Aaron W. Garrett
- Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | - Robert G. Rupard
- Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | | | - Tony M. Cooper
- Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | - David P. Myers
- Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| | - Bryan C. Castle
- Eli Lilly and Company, Indianapolis, Indiana 46285, United States
| |
Collapse
|
47
|
Alam MA, Shi Z, Drennen JK, Anderson CA. In-line monitoring and optimization of powder flow in a simulated continuous process using transmission near infrared spectroscopy. Int J Pharm 2017; 526:199-208. [DOI: 10.1016/j.ijpharm.2017.04.054] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 04/19/2017] [Accepted: 04/22/2017] [Indexed: 11/29/2022]
|
48
|
Teżyk M, Jakubowska E, Milczewska K, Milanowski B, Voelkel A, Lulek J. The influence of direct compression powder blend transfer method from the container to the tablet press on product critical quality attributes: a case study. Drug Dev Ind Pharm 2017; 43:911-916. [PMID: 28032521 DOI: 10.1080/03639045.2016.1278016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVE The aim of this article is to compare the gravitational powder blend loading method to the tablet press and manual loading in terms of their influence on tablets' critical quality attributes (CQA). SIGNIFICANCE The results of the study can be of practical relevance to the pharmaceutical industry in the area of direct compression of low-dose formulations, which could be prone to content uniformity (CU) issues. METHODS In the preliminary study, particle size distribution (PSD) and surface energy of raw materials were determined using laser diffraction method and inverse gas chromatography, respectively. For trials purpose, a formulation containing two pharmaceutical ingredients (APIs) was used. Tablet samples were collected during the compression progress to analyze their CQAs, namely assay and CU. RESULTS Results obtained during trials indicate that tested direct compression powder blend is sensitive to applied powder handling method. Mild increase in both APIs content was observed during manual scooping. Gravitational approach (based on discharge into the drum) resulted in a decrease in CU, which is connected to a more pronounced assay increase at the end of tableting than in the case of manual loading. CONCLUSIONS The correct design of blend transfer over single unit processes is an important issue and should be investigated during the development phase since it may influence the final product CQAs. The manual scooping method, although simplistic, can be a temporary solution to improve the results of API's content and uniformity when compared to industrial gravitational transfer.
Collapse
Affiliation(s)
- Michał Teżyk
- a Gedeon Richter Polska Sp. z o.o , Grodzisk Mazowiecki , Poland.,b Department of Pharmaceutical Technology, Faculty of Pharmacy , Poznan University of Medical Sciences , Poznan , Poland
| | - Emilia Jakubowska
- b Department of Pharmaceutical Technology, Faculty of Pharmacy , Poznan University of Medical Sciences , Poznan , Poland
| | - Kasylda Milczewska
- c Institute of Chemical Technology and Engineering, Poznan University of Technology , Poznan , Poland
| | - Bartłomiej Milanowski
- b Department of Pharmaceutical Technology, Faculty of Pharmacy , Poznan University of Medical Sciences , Poznan , Poland
| | - Adam Voelkel
- c Institute of Chemical Technology and Engineering, Poznan University of Technology , Poznan , Poland
| | - Janina Lulek
- b Department of Pharmaceutical Technology, Faculty of Pharmacy , Poznan University of Medical Sciences , Poznan , Poland
| |
Collapse
|
49
|
Colón YM, Vargas J, Sánchez E, Navarro G, Romañach RJ. Assessment of Robustness for a Near-Infrared Concentration Model for Real-Time Release Testing in a Continuous Manufacturing Process. J Pharm Innov 2016. [DOI: 10.1007/s12247-016-9265-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
50
|
Near infrared spectroscopic calibration models for real time monitoring of powder density. Int J Pharm 2016; 512:61-74. [DOI: 10.1016/j.ijpharm.2016.08.029] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Revised: 07/20/2016] [Accepted: 08/13/2016] [Indexed: 11/19/2022]
|