1
|
Czajkowska A, Korsak D, Fiedoruk-Pogrebniak M, Koncki R, Strzelak K. Turbidimetric flow analysis system for the investigation of microbial growth. Talanta 2024; 268:125303. [PMID: 37852015 DOI: 10.1016/j.talanta.2023.125303] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 10/03/2023] [Accepted: 10/07/2023] [Indexed: 10/20/2023]
Abstract
The monitoring of life of microbial populations is of the uttermost importance in environmental and food analysis, agriculture, as well as in medicine. The duration of bacteria adaptation to new environmental conditions, its lifetime and the divisions' pace are the key information in many studies. It was found that the fully-mechanized flow analysis system based on solenoid valves and pumps, paired with a dedicated flow-through optoelectronic detector can be successfully applied for monitoring of bacteria growth. The applicability of the designed multicommutated flow analysis (MCFA) system was proved by analysis of solutions containing bacteria cells proceeded by tests of McFarland (McF) standards. The developed setup allowed modelling and simulation of microbial growth, as well as monitoring of the bacteria growth in real-time manner to be carried out. The monitor is useful for the quantitative estimation of the basic parameters of bacteria population like its size, the rate of bacteria multiplication, as well as the times of lag, log and stationary phases of microbial growth.
Collapse
Affiliation(s)
| | - Dorota Korsak
- Faculty of Biology, University of Warsaw, Warsaw, Poland
| | | | - Robert Koncki
- Faculty of Chemistry, University of Warsaw, Warsaw, Poland
| | - Kamil Strzelak
- Faculty of Chemistry, University of Warsaw, Warsaw, Poland.
| |
Collapse
|
2
|
Malicka I, Lewińska I, Tymecki Ł. On-line 'protein shaker': A multicommutated flow analysis system for fluorometric creatinine determination in deproteinized serum. Anal Chim Acta 2022; 1191:339246. [PMID: 35033258 DOI: 10.1016/j.aca.2021.339246] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 10/27/2021] [Accepted: 11/01/2021] [Indexed: 11/26/2022]
Abstract
A fully mechanized multicommutated flow analysis (MCFA) system for fluorometric determination of creatinine in serum samples is introduced in this paper. The flow system was constructed with microsolenoid pumps and valves and with a 3D-printed flow cell. Fluorometric assay relied on creatinine reaction with 3,5-dinitrobenzoic acid and hydrogen peroxide in an alkaline environment. To overcome significant interference from protein, a flow reactor for serum deproteinization was designed and implemented in the flow system. The deproteinization was carried out by precipitation with trichloroacetic acid and the addition of sodium chloride facilitated the precipitate sedimentation. The supernatant representative sample was pumped out and subjected to fluorometric creatinine assay. The obtained linear range was from 1.6 to 500 μmol L-1 and the precision, expressed as RSD, was below 3%. The proposed MCFA system was used to determine creatinine concentration in control serum samples. The results obtained with flow deproteinization correlated well with results obtained with conventional deproteinization (y = (0.91 ± 0.09) x + (37 ± 28)) with Pearson's r 0.979.
Collapse
Affiliation(s)
- Iga Malicka
- University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093, Warsaw, Poland
| | - Izabela Lewińska
- University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093, Warsaw, Poland.
| | - Łukasz Tymecki
- University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093, Warsaw, Poland
| |
Collapse
|
3
|
Bzura J, Korsak D, Koncki R. Bioanalytical insight into the life of microbial populations: A chemical monitoring of ureolytic bacteria growth. Enzyme Microb Technol 2021; 153:109899. [PMID: 34670184 DOI: 10.1016/j.enzmictec.2021.109899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 08/23/2021] [Accepted: 08/27/2021] [Indexed: 11/03/2022]
Abstract
In this publication an alternative approach to investigations of bacterial growth is proposed. Contrary to the conventional physical methods it is based on enzyme activity detection. The procedure for real-time and on-line monitoring of microbial ureolytic activity (applied as a model experimental biosystem) in the flow analysis format is presented. The developed fully-mechanized bioanalytical flow system is composed of solenoid micropumps and microvalves actuated by Arduino microcontroller. The photometric detection based on Nessler reaction is performed using dedicated flow-through optoelectronic detector made of paired light emitting diodes. The developed bioanalytical system allows discrete assaying of microbial urease in the wide range of activity up to 5.4 U mL-1 with detection limit below 0.44 U mL-1, a high sensitivity in the linear range of response (up to 200 mV U-1 mL and relatively high throughput (9 detection per hour). The proposed differential procedure of measurements (i.e. a difference between peaks register for sample with and without external addition of urea is treated as an analytical signal) allows elimination of interfering effects from substrate and products of biocatalysed reaction as well as other components of medium used for microbial growth. The developed bioanalytical system was successfully applied for the control of growth of urease-positive bacteria strains (Proteus vulgaris, Klebsiella pneumoniae and Paracoccus yeei) including examination of effects from various microbial cultivation conditions like temperature, composition of culture medium and amount of substrate required for induction of bacterial enzymatic activity. The developed bioanalytical flow system can be applied for metabolic activity-based estimation of parameters of lag and log phases of microbial growth as well as for detection of decline phase.
Collapse
Affiliation(s)
- Justyna Bzura
- Faculty of Chemistry, University of Warsaw, L. Pasteura 1, 02-093, Warsaw, Poland
| | - Dorota Korsak
- Faculty of Biology, University of Warsaw, I. Miecznikowa 1, 02-096, Warsaw, Poland
| | - Robert Koncki
- Faculty of Chemistry, University of Warsaw, L. Pasteura 1, 02-093, Warsaw, Poland.
| |
Collapse
|
4
|
From the bottom of an old jar: A fluorometric method for the determination of creatinine in human serum. Anal Chim Acta 2020; 1135:116-122. [DOI: 10.1016/j.aca.2020.08.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 08/08/2020] [Accepted: 08/11/2020] [Indexed: 01/11/2023]
|
5
|
Chaneam S, Kaewyai K, Mantim T, Chaisuksant R, Wilairat P, Nacapricha D. Simultaneous and direct determination of urea and creatinine in human urine using a cost-effective flow injection system equipped with in-house contactless conductivity detector and LED colorimeter. Anal Chim Acta 2019; 1073:54-61. [DOI: 10.1016/j.aca.2019.05.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 04/17/2019] [Accepted: 05/02/2019] [Indexed: 12/15/2022]
|
6
|
MANTHONG N, WILAIRAT P, NACAPRICHA D, CHANEAM S. Simultaneous Colorimetric Measurements of Antioxidant Capacity by Flow Injection Analysis with Paired Emitter Detector Diode. ANAL SCI 2019; 35:535-541. [DOI: 10.2116/analsci.18p512] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Nantaya MANTHONG
- Department of Chemistry, Faculty of Science, Silpakorn University
| | - Prapin WILAIRAT
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs.)
- National Doping Control Centre, Mahidol University
| | - Duangjai NACAPRICHA
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs.)
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University
| | - Sumonmarn CHANEAM
- Department of Chemistry, Faculty of Science, Silpakorn University
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs.)
| |
Collapse
|
7
|
Strzelak K, Koncki R. A remote-controlled immunochemical system for nephelometric detection of human serum transferrin. Biosens Bioelectron 2019; 127:31-37. [DOI: 10.1016/j.bios.2018.12.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
8
|
Modern creatinine (Bio)sensing: Challenges of point-of-care platforms. Biosens Bioelectron 2019; 130:110-124. [PMID: 30731344 DOI: 10.1016/j.bios.2019.01.048] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2018] [Revised: 01/11/2019] [Accepted: 01/20/2019] [Indexed: 01/01/2023]
Abstract
The importance of knowing creatinine levels in the human body is related to the possible association with renal, muscular and thyroid dysfunction. Thus, the accurate detection of creatinine may indirectly provide information surrounding those functional processes, therefore contributing to the management of the health status of the individual and early diagnosis of acute diseases. The questions at this point are: to what extent is creatinine information clinically relevant?; and do modern creatinine (bio)sensing strategies fulfil the real needs of healthcare applications? The present review addresses these questions by means of a deep analysis of the creatinine sensors reported in the literature over the last five years. There is a wide range of techniques for detecting creatinine, most of them based on optical readouts (20 of the 33 papers collected in this review). However, the use of electrochemical techniques (13 of the 33 papers) is recently emerging in alignment with the search for a definitive and trustworthy creatinine detection at the point-of-care level. In this sense, biosensors (7 of the 33 papers) are being established as the most promising alternative over the years. While creatinine levels in the blood seem to provide better information about patient status, none of the reported sensors display adequate selectivity in such a complex matrix. In contrast, the analysis of other types of biological samples (e.g., saliva and urine) seems to be more viable in terms of simplicity, cross-selectivity and (bio)fouling, besides the fact that its extraction does not disturb individual's well-being. Consequently, simple tests may likely be used for the initial check of the individual in routine analysis, and then, more accurate blood detection of creatinine could be necessary to provide a more genuine diagnosis and/or support the corresponding decision-making by the physician. Herein, we provide a critical discussion of the advantages of current methods of (bio)sensing of creatinine, as well as an overview of the drawbacks that impede their definitive point-of-care establishment.
Collapse
|
9
|
Bzura J, Koncki R. A mechanized urease activity assay. Enzyme Microb Technol 2019; 123:1-7. [PMID: 30686345 DOI: 10.1016/j.enzmictec.2019.01.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 12/30/2018] [Accepted: 01/02/2019] [Indexed: 11/19/2022]
Abstract
Two fully mechanized flow analysis systems for urease activity assays have been developed, characterized and compared. Both of them are based on almost the same compact system of solenoid micropumps and microvalves controlled and actuated by highly effective, low-power and economic Arduino microcontroller. For photometric detection of ammonia formed in the course of enzymatic hydrolysis of urea, the Berthelot method and the Nessler reaction have been examined. For both these detection schemes very simple dedicated optoelectronic flow-through detectors made of paired light emitting diodes have been developed. In both systems single enzyme assay lasting a few minutes allows determination of urease in activity range 0.02-5.3 U mL-1 with detection limit 0.02 U mL-1 and in 1.3-5.3 U mL-1 range with 0.75 U mL-1 detection limit for Nessler reaction and Berthelot method based systems, respectively. When compared with mechanized Berthelot method, the bioanalytical system based on Nessler reaction offers higher sensitivity, lower detection/determination limits, better selectivity and lower cost of the assay. It has been demonstrated that the developed bioanalytical flow systems could be useful for urease determination in complex biological matrix like plant extracts and media for microbial cultures as well as for inhibitive determination of heavy metals at sub-ppm levels.
Collapse
Affiliation(s)
- Justyna Bzura
- University of Warsaw, Faculty of Chemistry, L. Pasteura 1, 02-093, Warsaw, Poland.
| | - Robert Koncki
- University of Warsaw, Faculty of Chemistry, L. Pasteura 1, 02-093, Warsaw, Poland
| |
Collapse
|
10
|
Rybkowska N, Koncki R, Strzelak K. Optoelectronic iron detectors for pharmaceutical flow analysis. J Pharm Biomed Anal 2017; 145:504-508. [PMID: 28746909 DOI: 10.1016/j.jpba.2017.06.057] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 06/22/2017] [Accepted: 06/25/2017] [Indexed: 11/29/2022]
Abstract
Compact flow-through optoelectronic detectors fabricated by pairing of light emitting diodes have been applied for development of economic flow analysis systems dedicated for iron ions determination. Three analytical methods with different chromogens selectively recognizing iron ions have been compared. Ferrozine and ferene S based methods offer higher sensitivity and slightly lower detection limits than method with 1,10-phenantroline, but narrower ranges of linear response. Each system allows detection of iron in micromolar range of concentration with comparable sample throughput (20 injections per hour). The developed flow analysis systems have been successfully applied for determination of iron in diet supplements. The utility of developed analytical systems for iron release studies from drug formulations has also been demonstrated.
Collapse
Affiliation(s)
- Natalia Rybkowska
- University of Warsaw, Department of Chemistry, Pasteura 1, 02-093, Warsaw, Poland.
| | - Robert Koncki
- University of Warsaw, Department of Chemistry, Pasteura 1, 02-093, Warsaw, Poland
| | - Kamil Strzelak
- University of Warsaw, Department of Chemistry, Pasteura 1, 02-093, Warsaw, Poland
| |
Collapse
|
11
|
Michalec M, Fiedoruk-Pogrebniak M, Matuszkiewicz-Rowińska J, Tymecki Ł, Koncki R. Biomedical monitoring of phosphate removal by hemodialysis. J Pharm Biomed Anal 2016; 126:9-13. [DOI: 10.1016/j.jpba.2016.04.034] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 04/20/2016] [Accepted: 04/21/2016] [Indexed: 10/21/2022]
|