1
|
Wang T, Yang H, Yang J, Guo N, Wu G, Xu X, An M. Quantitative Determination of Four Potential Genotoxic Impurities in the Active Pharmaceutical Ingredients in TSD-1 Using UPLC-MS/MS. Molecules 2022; 27:molecules27134129. [PMID: 35807373 PMCID: PMC9268482 DOI: 10.3390/molecules27134129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 06/19/2022] [Accepted: 06/25/2022] [Indexed: 11/30/2022] Open
Abstract
A novel method of ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed for the identification and quantification of four potential genotoxic impurities (PGIs) in the active pharmaceutical ingredients of TSD-1, a novel P2Y12 receptor antagonist. Four PGIs were named, 4-nitrobenzenesulfonic acid, methyl 4-nitrobenzenesulfonate, ethyl 4-nitrobenzenesulfonate, and isopropyl 4-nitrobenzenesulfonate. Following the International Conference of Harmonization (ICH) guidelines, this methodology is capable of quantifying four PGIs at 15.0 ppm in samples of 0.5 mg/mL concentration. This validated approach presented very low limits (0.1512−0.3897 ng/mL), excellent linearity (coefficients > 0.9900), and a satisfactory recovery range (94.9−115.5%). The method was sufficient in terms of sensitivity, linearity, precision, accuracy, selectivity, and robustness and, thus, has high practicality in the pharmaceutical quality control of TSD-1.
Collapse
Affiliation(s)
- Taiyu Wang
- Department of Pharmacy, Baotou Medical College, Inner Mongolia University of Science and Technology, Baotou 014060, China; (T.W.); (G.W.)
- Chemical Pharmaceutical Research Center, Tasly Academy, Tasly Holding Group Co., Ltd., Tianjin 300410, China; (H.Y.); (J.Y.)
| | - Hailong Yang
- Chemical Pharmaceutical Research Center, Tasly Academy, Tasly Holding Group Co., Ltd., Tianjin 300410, China; (H.Y.); (J.Y.)
| | - Jie Yang
- Chemical Pharmaceutical Research Center, Tasly Academy, Tasly Holding Group Co., Ltd., Tianjin 300410, China; (H.Y.); (J.Y.)
| | - Ningjie Guo
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou 450001, China;
| | - Guodong Wu
- Department of Pharmacy, Baotou Medical College, Inner Mongolia University of Science and Technology, Baotou 014060, China; (T.W.); (G.W.)
| | - Xueyu Xu
- Chemical Pharmaceutical Research Center, Tasly Academy, Tasly Holding Group Co., Ltd., Tianjin 300410, China; (H.Y.); (J.Y.)
- Correspondence: (X.X.); (M.A.)
| | - Ming An
- Department of Pharmacy, Baotou Medical College, Inner Mongolia University of Science and Technology, Baotou 014060, China; (T.W.); (G.W.)
- Correspondence: (X.X.); (M.A.)
| |
Collapse
|
2
|
High-Performance Pd/AC Catalyst for Meropenem Synthesis Based on Selective Surface Modification of Activated Carbon. Catal Letters 2021. [DOI: 10.1007/s10562-021-03783-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
3
|
Abrão LCDC, Silveira AT, de Faria HD, Machado SC, Mendes TV, Plácido RV, Marciano LPDA, Martins I. Toxicological analyses: analytical method validation for prevention or diagnosis. Toxicol Mech Methods 2020; 31:18-32. [PMID: 33081560 DOI: 10.1080/15376516.2020.1839612] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The need for reliable results in Toxicological Analysis is recognized and required worldwide. The analytical validation ensures that a method will provide trustworthy information about a particular sample when applied in accordance with a predefined protocol, being able to determine a specific analyte at a distinct concentration range for a well-defined purpose. The driving force for developing method validation for bioanalytical projects comes from the regulatory agencies. Thus, the approach of this work is to present theoretical and practical aspects of method validation based on the analysis objective, whether for prevention or diagnosis. Although various legislative bodies accept differing interpretations of requirements for validation, the process for applying validation criteria should be adaptable for each scientific intent or analytical purpose.
Collapse
Affiliation(s)
| | - Alberto Thalison Silveira
- Laboratory of Toxicant and Drug Analysis, Federal University of Alfenas - Unifal-MG, Alfenas, Brazil
| | - Henrique Dipe de Faria
- Laboratory of Toxicant and Drug Analysis, Federal University of Alfenas - Unifal-MG, Alfenas, Brazil
| | - Simone Caetani Machado
- Laboratory of Toxicant and Drug Analysis, Federal University of Alfenas - Unifal-MG, Alfenas, Brazil
| | - Tássia Venga Mendes
- Laboratory of Toxicant and Drug Analysis, Federal University of Alfenas - Unifal-MG, Alfenas, Brazil
| | - Rodrigo Vicentino Plácido
- Laboratory of Toxicant and Drug Analysis, Federal University of Alfenas - Unifal-MG, Alfenas, Brazil
| | | | - Isarita Martins
- Laboratory of Toxicant and Drug Analysis, Federal University of Alfenas - Unifal-MG, Alfenas, Brazil
| |
Collapse
|
4
|
Kammoun AK, Khedr A, Khayyat AN, Hegazy MA. Ultra-performance liquid chromatography-tandem mass spectrometric method for quantitation of the recently Food and Drug Administration approved combination of vaborbactam and meropenem in human plasma. ROYAL SOCIETY OPEN SCIENCE 2020; 7:200635. [PMID: 32874656 PMCID: PMC7428257 DOI: 10.1098/rsos.200635] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Accepted: 06/12/2020] [Indexed: 06/11/2023]
Abstract
A parenteral medical combination containing vaborbactam and meropenem is used mainly to treat complicated urinary tract infections. A novel ultra-performance liquid chromatography tandem mass spectrometric method was developed for the sensitive determination of both compounds in human plasma. Sample preparation was performed by precipitation technique. The chromatographic separation was accomplished using the Acquity C18-BEH column, 0.01 M ammonium formate: acetonitrile (47 : 53, v/v) as a mobile phase with a flow rate of 0.2 ml min-1. Analytes were monitored by applying multiple reaction monitoring. The bioanalytical validation criteria were conducted following the Food and Drug Administration recommendations. The method was linear within range 0.5 to 50 µg ml-1, for both drugs. The intra-day and inter-day precision, as coefficient variation (% CV) and the accuracy, as % bias did not exceed 15% for both drugs. The percentage recovery of targeted analytes was not less than 77%, calculated at three quality control levels. The proposed method showed a suitable lower level of quantification value of 0.50 µg ml-1 for both analytes, which is far lower than the expected C max, which permits the use of this method for pharmacokinetic studies. The proposed method proved to be useful for the evaluation of this combination in both human plasma and pharmaceutical formulation.
Collapse
Affiliation(s)
- Ahmed K. Kammoun
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, King Abdulaziz University, PO Box 80260, Jeddah 21589, Saudi Arabia
| | - Alaa Khedr
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, King Abdulaziz University, PO Box 80260, Jeddah 21589, Saudi Arabia
| | - Ahdab N. Khayyat
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, King Abdulaziz University, PO Box 80260, Jeddah 21589, Saudi Arabia
| | - Maha A. Hegazy
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, 11562 Cairo, Egypt
| |
Collapse
|
5
|
Koçoğlu ES, Sözüdoğru O, Komesli OT, Yılmaz AE, Er EÖ, Bakırdere S. Sensitive Determination of Selected Drug Active Compounds in Wastewater Matrices by LC-QTOF-MS/MS after Vortex Assisted Binary Solvents Dispersive Liquid-Liquid Microextraction. CHEM LETT 2020. [DOI: 10.1246/cl.200066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- E. Seda Koçoğlu
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Turkey
| | - Onur Sözüdoğru
- Atatürk University, Department of Environmental Engineering, 25240 Erzurum, Turkey
| | - Okan T. Komesli
- Atatürk University, Department of Environmental Engineering, 25240 Erzurum, Turkey
| | - Alper E. Yılmaz
- Atatürk University, Department of Environmental Engineering, 25240 Erzurum, Turkey
| | - Elif Öztürk Er
- Yıldız Technical University, Department of Chemical Engineering, 34220 İstanbul, Turkey
| | - Sezgin Bakırdere
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Turkey
| |
Collapse
|
6
|
Chen Y, Wu S, Yang Q. Development and Validation of LC-MS/MS for Analyzing Potential Genotoxic Impurities in Pantoprazole Starting Materials. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2020; 2020:6597363. [PMID: 32211210 PMCID: PMC7085375 DOI: 10.1155/2020/6597363] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 01/21/2020] [Accepted: 02/08/2020] [Indexed: 06/10/2023]
Abstract
Pantoprazole sodium (PPZS) is a selective proton pump inhibitor used in the prevention and treatment of gastric acid-related diseases. Six potentially genotoxic impurities (PGIs) are involved in 5-difluoromethoxy-2-mercapto-1H-benzimidazole (DMBZ), which is the starting material of PPZS. To date, no suitable method has yet been developed for PGI separation and quantification at the threshold of toxicological concern levels. In this study, a sensitive and reliable liquid chromatography-tandem mass spectrometry method was developed and validated for the quantitative analysis of six PGIs in DMBZ according to the guidelines of the International Council for Harmonization (ICH). The calibration curves showed good linearity within the studied range, and the correlation coefficient of fitting exceeded 0.998 for each impurity. The sensitivity of the proposed method was in the range of 0.6-10.0 ng/mL. Good recoveries were observed in the range of 94.32%-107.43% with RSD values below 6.5%. Quantitative analysis of impurities in substance batches of DMBZ showed the high efficiency of the developed method at a low level. Hence, the proposed method is practical and useful in the detection and qualification of PGIs in DMBZ and may be applied to ensure the safe use of PPZS in clinical treatment.
Collapse
Affiliation(s)
- Yuyuan Chen
- Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, China
| | - Song Wu
- Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, China
| | - Qingyun Yang
- Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100050, China
| |
Collapse
|
7
|
Dispersive liquid-liquid microextraction with high-performance liquid chromatography for the analysis of 1,4-benzodioxane-6-aldehyde in eliglustat tartrate active pharmaceutical ingredient. J Pharm Biomed Anal 2020; 179:112988. [PMID: 31812805 DOI: 10.1016/j.jpba.2019.112988] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2019] [Revised: 11/10/2019] [Accepted: 11/11/2019] [Indexed: 11/20/2022]
Abstract
Potential genotoxic impurities (PGIs) are a series of compounds that could potentially damage DNA. Therefore, a sensitive method is needed for detection and quantification. The present work described and validated a method for the quantification of one PGI (namely 1,4-benzodioxane-6-aldehyde) in Eliglustat tartrate (EGT) active pharmaceutical ingredient (API) substances using dispersive liquid-liquid microextraction (DLLME) as sample preparation to remove matrix effect and detected by HPLC-UV. Parameters influencing the microextraction efficiency were systematically investigated. The combined application of DLLME and HPLC-UV provided the sensitivity of the method. The achieved limit of detection (LOD) and the limit of quantification (LOQ) were adequate for the specific purpose and found to be 1.29 μg g-1 and 2.58 μg g-1, respectively. This simple and effective methodology offers a key advantage in the ease of removing matrix effect and improves sensitivity obviously. In addition, no costly instrumentation and skilled personnel are needed when using this method, which is available and can be successfully implemented in routine factory drug quality control analysis.
Collapse
|
8
|
Determination of epoxide impurity in sarpogrelate hydrochloride intermediate by UHPLC and column-switching liquid chromatography. J Pharm Biomed Anal 2019; 174:57-62. [DOI: 10.1016/j.jpba.2019.05.053] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 05/22/2019] [Accepted: 05/23/2019] [Indexed: 12/15/2022]
|
9
|
Shelke M, Deshpande SS, Sharma S. Quinquennial Review of Progress in Degradation Studies and Impurity Profiling: An Instrumental Perspective Statistics. Crit Rev Anal Chem 2019; 50:226-253. [DOI: 10.1080/10408347.2019.1615863] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- Madhav Shelke
- School of Pharmacy & Technology Management, SVKM's NMIMS, Shirpur, Maharashtra, India
| | | | | |
Collapse
|
10
|
Robust Optimization of Chaotropic Chromatography Assay for Lamotrigine and its Two Impurities in Tablets. Chromatographia 2018. [DOI: 10.1007/s10337-018-3661-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
11
|
Wingert NR, Arbo MD, Göethel G, da Costa B, Altknecht LF, Garcia SC, Steppe M. In vitro toxicity assessment of rivaroxaban degradation products and kinetic evaluation to decay process. Drug Chem Toxicol 2018; 42:509-518. [PMID: 29644883 DOI: 10.1080/01480545.2018.1452931] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Degradation kinetics of oral anticoagulant rivaroxaban (RIV) was assessed in acid and alkaline media and while exposed to UVC radiation. Among all stress conditions tested, kinetic degradation process was better described by a zero-order model. A stability indicating method was validated for the analysis of the anticoagulant RIV in tablets by high-performance liquid chromatography. Robustness was evaluated with a two-level Plackett-Burman experimental design. The effect of acute exposition of the human hepatoblastoma HepG2 cell line to RIV stressed samples (100 and 500 µM) was assessed through in vitro toxicity tests. MTT reduction, neutral red uptake, mitochondrial membrane potential, and low molecular weight DNA diffusion assays were employed for cytotoxicity evaluation (5×104 cells/well). The genotoxic potential was assessed by comet assay (2×104 cells/well). Acute toxicity to HepG2 cells was assessed after 24 h incubation with sample solutions, for each test. A direct relationship between the increased amount of alkaline degradation products and higher cytotoxic potential was found. Results obtained by viability assay investigations support the concerns on risks associated with acute toxicity and genotoxicity of pharmaceutical samples containing degradation products as impurities.
Collapse
Affiliation(s)
- Nathalie R Wingert
- a Laboratory of Pharmaceutical Quality Control (LCQFar) , Federal University of Rio Grande do Sul , Porto Alegre , Brazil
| | - Marcelo D Arbo
- b Laboratory of Toxicology (LATOX) , Federal University of Rio Grande do Sul , Porto Alegre , Brazil
| | - Gabriela Göethel
- b Laboratory of Toxicology (LATOX) , Federal University of Rio Grande do Sul , Porto Alegre , Brazil
| | - Bárbara da Costa
- b Laboratory of Toxicology (LATOX) , Federal University of Rio Grande do Sul , Porto Alegre , Brazil
| | - Louise F Altknecht
- b Laboratory of Toxicology (LATOX) , Federal University of Rio Grande do Sul , Porto Alegre , Brazil
| | - Solange C Garcia
- b Laboratory of Toxicology (LATOX) , Federal University of Rio Grande do Sul , Porto Alegre , Brazil
| | - Martin Steppe
- a Laboratory of Pharmaceutical Quality Control (LCQFar) , Federal University of Rio Grande do Sul , Porto Alegre , Brazil
| |
Collapse
|
12
|
Teasdale A, Elder DP. Analytical control strategies for mutagenic impurities: Current challenges and future opportunities? Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2017.10.027] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
13
|
Analysis of potential genotoxic impurities in rabeprazole active pharmaceutical ingredient via Liquid Chromatography-tandem Mass Spectrometry, following quality-by-design principles for method development. J Pharm Biomed Anal 2018; 149:410-418. [DOI: 10.1016/j.jpba.2017.11.037] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2017] [Revised: 11/10/2017] [Accepted: 11/11/2017] [Indexed: 11/20/2022]
|