1
|
Visconti G, de Figueiredo M, Monnier J, Shea J, Rudaz S, Glauser G. Fast neonicotinoid quantification in honey using the one-point internal calibration approach. Food Chem X 2024; 23:101565. [PMID: 39007114 PMCID: PMC11239451 DOI: 10.1016/j.fochx.2024.101565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 05/31/2024] [Accepted: 06/14/2024] [Indexed: 07/16/2024] Open
Abstract
Neonicotinoids, a highly effective class of insecticides used worldwide, have been identified as a major cause of concern for biodiversity. To assess the ecological and environmental consequences of neonicotinoids' use, reliable analytical methodologies, including calibration approaches, are needed. Here, we compared the performance of internal calibration (IC) using a single concentration of stable isotope-labeled standard (SIL) with classical multipoint external calibration (EC) for the quantification of six neonicotinoids in honey. IC showed acceptable levels of trueness (86.3% - 116.0%) and precision (1.4% - 20.8%), although slight biases were observed at very low concentrations compared to EC. When applied to 32 original honey samples, both approaches showed strong agreement (R2 > 0.998) with proportional biases lower than 5%. These results highlight the possibility of implementing IC to simplify quantification in liquid chromatography-mass spectrometry-based pesticide applications.
Collapse
Affiliation(s)
- Gioele Visconti
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
| | - Miguel de Figueiredo
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
| | - Joanie Monnier
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
- Neuchâtel Platform of Analytical Chemistry (NPAC), University of Neuchâtel, Avenue de Bellevaux 51, 2000 Neuchâtel, Switzerland
| | - Julia Shea
- Neuchâtel Platform of Analytical Chemistry (NPAC), University of Neuchâtel, Avenue de Bellevaux 51, 2000 Neuchâtel, Switzerland
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
| | - Gaetan Glauser
- Neuchâtel Platform of Analytical Chemistry (NPAC), University of Neuchâtel, Avenue de Bellevaux 51, 2000 Neuchâtel, Switzerland
| |
Collapse
|
2
|
Sun F, Li Y, Tan H, Wu P, Shencheng Y, Lin H, Lu P, Zhang R, Liu S, Li Y, Yang S. Integrating a Multiple Isotopologue Reaction-Monitoring Technique and LC-MS/MS for Quantitation of Small Molecules: Ten Mycotoxins in Cereals as an Example. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2024; 72:6638-6650. [PMID: 38482854 DOI: 10.1021/acs.jafc.3c08828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/28/2024]
Abstract
Accurate quantification of mycotoxin in cereals is crucial for ensuring food safety and human health. However, the preparation of traditional multisample external calibration curves (MSCCs) is labor-intensive and error-prone. Here, a multiple isotopologue reaction-monitoring (MIRM)-LC-MS/MS method for accurate quantitation of ten major mycotoxins in cereals was successfully developed and validated, where a novel one-sample multipoint calibration curve (OSCC) strategy is used instead of MSCCs. The OSCC can be established by examining the correlation between the calculated theoretical isotopic abundances and the measured abundance across various MIRM channels. In comparison to the MSCC, the OSCC strategy exhibits outstanding performance including superior selectivity, accuracy (78.4-108.6%), and precision (<12.5%). Furthermore, the proposed OSCC-MIRM-LC-MS/MS method was successfully applied to investigate mycotoxin contamination in cereal samples in China. Considering the advantages of simplified workflows and improved throughput, the OSCC-MIRM-LC-MS/MS methodology holds great promise for accurately quantifying chemical contaminants in foods.
Collapse
Affiliation(s)
- Feifei Sun
- Animal-Derived Food Safety Innovation Team, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, People's Republic of China
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Yanshen Li
- College of Life Science, Yantai University, Yantai 264005, Shandong, People's Republic of China
| | - Haiguang Tan
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Peixu Wu
- Animal-Derived Food Safety Innovation Team, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, People's Republic of China
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Yingnan Shencheng
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Haopeng Lin
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Peng Lu
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Rong Zhang
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Shuyan Liu
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Yi Li
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Shupeng Yang
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| |
Collapse
|
3
|
Visconti G, de Figueiredo M, Salamin O, Boccard J, Vuilleumier N, Nicoli R, Kuuranne T, Rudaz S. Straightforward quantification of endogenous steroids with liquid chromatography-tandem mass spectrometry: Comparing calibration approaches. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1226:123778. [PMID: 37393882 DOI: 10.1016/j.jchromb.2023.123778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 05/23/2023] [Accepted: 05/31/2023] [Indexed: 07/04/2023]
Abstract
Different calibration strategies are used in liquid chromatography hyphenated to mass spectrometry (LC-MS) bioanalysis. Currently, the surrogate matrix and surrogate analyte represent the most widely used approaches to compensate for the lack of analyte-free matrices in endogenous compounds quantification. In this context, there is a growing interest in rationalizing and simplifying quantitative analysis using a one-point concentration level of stable isotope-labeled (SIL) standards as surrogate calibrants. Accordingly, an internal calibration (IC) can be applied when the instrument response is translated into analyte concentration via the analyte-to-SIL ratio performed directly in the study sample. Since SILs are generally used as internal standards to normalize variability between authentic study sample matrix and surrogate matrix used for the calibration, IC can be calculated even if the calibration protocol was achieved for an external calibration (EC). In this study, a complete dataset of a published and fully validated method to quantify an extended steroid profile in serum was recomputed by adapting the role of SIL internal standards as surrogate calibrants. Using the validation samples, the quantitative performances for IC were comparable with the original method, showing acceptable trueness (79%-115%) and precision (0.8%-11.8%) for the 21 detected steroids. The IC methodology was then applied to human serum samples (n = 51) from healthy women and women diagnosed with mild hyperandrogenism, showing high agreement (R2 > 0.98) with the concentrations obtained using the conventional quantification based on EC. For IC, Passing-Bablok regression showed proportional biases between -15.0% and 11.3% for all quantified steroids, with an average difference of -5.8% compared to EC. These results highlight the reliability and the advantages of implementing IC in clinical laboratories routine to simplify quantification in LC-MS bioanalysis, especially when a large panel of analytes is monitored.
Collapse
Affiliation(s)
- Gioele Visconti
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
| | - Miguel de Figueiredo
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland
| | - Olivier Salamin
- Center of Research and Expertise in Anti-Doping Sciences - REDs, Institute of Sport Sciences, University of Lausanne, Lausanne, Switzerland; Swiss Laboratory for Doping Analyses, University Center of Legal Medicine, Lausanne and Geneva, Lausanne University Hospital and University of Lausanne, Switzerland
| | - Julien Boccard
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Basel, Switzerland
| | - Nicolas Vuilleumier
- Department of Genetic and Laboratory Medicine, Geneva University Hospitals (HUG), Geneva, Switzerland
| | - Raul Nicoli
- Swiss Laboratory for Doping Analyses, University Center of Legal Medicine, Lausanne and Geneva, Lausanne University Hospital and University of Lausanne, Switzerland
| | - Tiia Kuuranne
- Swiss Laboratory for Doping Analyses, University Center of Legal Medicine, Lausanne and Geneva, Lausanne University Hospital and University of Lausanne, Switzerland
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Basel, Switzerland.
| |
Collapse
|
4
|
Zhang H, Li Y, Abdallah MF, Tan H, Li J, Liu S, Zhang R, Sun F, Li Y, Yang S. Novel one-point calibration strategy for high-throughput quantitation of microcystins in freshwater using LC-MS/MS. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 858:159345. [PMID: 36270352 DOI: 10.1016/j.scitotenv.2022.159345] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 10/05/2022] [Accepted: 10/06/2022] [Indexed: 06/16/2023]
Abstract
Precise quantification of microcystins (MCs) in freshwater is crucial for environmental monitoring and human health. However, the preparation of traditional multi-sample external calibration curve (MSCC) is time consuming and prone to error. Here, a novel one-point calibration strategy including one sample multi-point calibration curve (OSCC) and in sample calibration curve (ISCC) is proposed for the quantitation of eight MCs in freshwater lakes using liquid chromatography tandem mass spectrometry (LC-MS/MS). The multiple isotopologue reaction monitoring (MIRM) of MCs and its 15N-labelled internal standards were used for OSCC and ISCC, respectively. The isotopic abundance of each MIRM channel could be calculated and measured accurately. Additionally, this strategy was comprehensively validated and showed good performance in selectivity, sensitivity, accuracy and precision as the traditional MSCC. Interestingly, OSCC could realize sample dilution by monitoring the less abundant MIRM transitions, while ISCC remove blank matrixes and generate calibration curve in each study samples. Furthermore, the proposed methodology was successfully applied to analyze several freshwater lake samples contaminated by MCs. Considering the advantages of excluding the MSCC preparation, simplified workflows and improved throughput, OSCC and ISCC will be favored for MCs monitoring and as an emerging approach in environmental pollutant control and prevention.
Collapse
Affiliation(s)
- Huiyan Zhang
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China; Institute of Animal Sciences, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China
| | - Yanshen Li
- College of Life Science, Yantai University, Yantai, Shandong 264005, PR China
| | - Mohamed F Abdallah
- Department of Food Technology, Safety and Health, Ghent University, Coupure Links 653, 9000 Ghent, Belgium; Department of Forensic Medicine and Toxicology, Faculty of Veterinary Medicine, Assiut University, Assiut 71515, Egypt
| | - Haiguang Tan
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China
| | - Jianxun Li
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China
| | - Shuyan Liu
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China
| | - Rong Zhang
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China
| | - Feifei Sun
- College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, PR China
| | - Yi Li
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China.
| | - Shupeng Yang
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, PR China.
| |
Collapse
|
5
|
Visconti G, Boccard J, Feinberg M, Rudaz S. From fundamentals in calibration to modern methodologies: A tutorial for small molecules quantification in liquid chromatography-mass spectrometry bioanalysis. Anal Chim Acta 2023; 1240:340711. [PMID: 36641149 DOI: 10.1016/j.aca.2022.340711] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 12/05/2022] [Accepted: 12/06/2022] [Indexed: 12/12/2022]
Abstract
Over the last two decades, liquid chromatography coupled to mass-spectrometry (LC‒MS) has become the gold standard to perform qualitative and quantitative analyses of small molecules. When quantitative analysis is developed, an analyst usually refers to international guidelines for analytical method validation. In this context, the design of calibration curves plays a key role in providing accurate results. During recent years and along with instrumental advances, strategies to build calibration curves have dramatically evolved, introducing innovative approaches to improve quantitative precision and throughput. For example, when a labeled standard is available to be spiked directly into the study sample, the concentration of the unlabeled analog can be easily determined using the isotopic pattern deconvolution or the internal calibration approach, eliminating the need for multipoint calibration curves. This tutorial aims to synthetize the advances in LC‒MS quantitative analysis for small molecules in complex matrices, going from fundamental aspects in calibration to modern methodologies and applications. Different work schemes for calibration depending on the sample characteristics (analyte and matrix nature) are distinguished and discussed. Finally, this tutorial outlines the importance of having international guidelines for analytical method validation that agree with the advances in calibration strategies and analytical instrumentation.
Collapse
Affiliation(s)
- Gioele Visconti
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland
| | - Julien Boccard
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland
| | | | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland.
| |
Collapse
|
6
|
One sample multi-point calibration curve as a novel approach for quantitative LC-MS analysis: the quantitation of six aflatoxins in milk and oat-based milk as an example. Food Chem 2023; 420:135593. [PMID: 37080113 DOI: 10.1016/j.foodchem.2023.135593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 01/11/2023] [Accepted: 01/26/2023] [Indexed: 01/31/2023]
Abstract
Preparing of calibration curves are critical steps for accurate quantitative LC-MS bioanalysis. Traditional multi-sample external calibration curve (MSCC) is labor-intensive and prone to error. In this study, a novel strategy of one sample multi-point calibration curve (OSCC) using multiple isotopologue reaction monitoring (MIRM) was proposed and validated using LC-MS for the quantitation of six aflatoxins in milk and oat-based milk samples. The developed MIRM-OSCC methodology is comprehensively validated and the results indicated that the established method exhibits good performance in selectivity, sensitivity, accuracy and precision. Furthermore, the OSCC could realize sample dilution by monitoring the MIRM channel with less intensity for samples beyond the upper limit of quantification, without the need of sample dilution, which improves the assay throughput. Considering the advantages of excluding the MSCC preparation and sample dilution in OSCC, this strategy can be widely applied in various fields such as drugs, food safety and environmental analysis.
Collapse
|
7
|
Kandi S, Savaryn JP, Ji QC, Jenkins GJ. Use of in-sample calibration curve approach for quantification of peptides with high-resolution mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9377. [PMID: 35940586 DOI: 10.1002/rcm.9377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 07/27/2022] [Accepted: 08/05/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE The in-sample calibration curve (ISCC) approach of quantification utilizes the response of isotopologue ions from spiked-in stable isotope labeled internal standard (SIL-IS) to build a standard curve. The quantitative analysis of the study sample is achieved based on the response of selected monoisotopic analyte ion against the calibration curve. Although this methodology has been demonstrated to be feasible by unit and high-resolution mass spectrometers, quantitation on high-resolution mass spectrometer with product ions has not been tested. We tested the feasibility of this approach using product ions on an high-resolution mass spectrometer equipped with an Orbitrap detector. METHODS Using a proteomics workflow for sample preparation, two surrogate peptides were quantified from a complex matrix of protein digest from human peripheral blood mononuclear cells (hPBMCs). SIL-IS was spiked in at different levels to construct calibration curves in a traditional manner. ISCCs were prepared using extracted ion chromatograms from isotopically resolved mass spectra and compared with traditional calibration curves. RESULTS A linear response was observed with ISCC approach for at least two to three orders of magnitude in MS1 as well as targeted MS2 (tMS2). From protein digests, isobaric interferences were observed for endogenous peptides on the MS1 level; this was circumvented with product-ion-based quantitation where for one peptide, %CV for endogenous levels was more than 20% with ISCC but higher with the traditional calibration curve approach. For the second peptide, endogenous levels could not be determined in the traditional approach as calibrant levels did not bracket the lower end, and with the ISCC approach, isotopologues at abundances lower than the endogenous level allowed for quantitative assessments. CONCLUSIONS ISCC demonstrated improved precision across surrogate peptides from endogenous protein digests. In samples where endogenous analyte concentrations were low in abundance, ISCC rescued what would have been a non-reportable result in a traditional bioanalytical assay as calibrant levels were not prepared at adequately low levels to bracket unknowns. ISCC using high-resolution mass spectrometer is feasible and ideal compared to unit resolution mass spectrometers. High-resolution mass spectrometer allows for isotopic resolution for analytes with > + 2 charge state and provides flexibility in quantification using multiple product ions. ISCC using high-resolution mass spectrometer allows for simultaneous assaying of low abundance isotopologues, the signal acquisition of which is not constrained by limits in data acquisition or calibrant preparation as with other approaches but rather limited by platform sensitivity. In contrast to unit resolution mass spectrometers, these features offered by high-resolution mass spectrometer could be especially useful for the drug discovery assay support where there is less lead time for assay development than for the assays to support the drug development studies.
Collapse
Affiliation(s)
- Soumya Kandi
- DMPK-BA, AbbVie Inc, North Chicago, Illinois, USA
| | | | - Qin C Ji
- DMPK-BA, AbbVie Inc, North Chicago, Illinois, USA
| | | |
Collapse
|
8
|
Sun F, Tan H, Abdallah MF, Li Y, Zhou J, Li Y, Yang S. A novel calibration strategy based on isotopic distribution for high-throughput quantitative analysis of pesticides and veterinary drugs using LC-HRMS. JOURNAL OF HAZARDOUS MATERIALS 2022; 430:128413. [PMID: 35183054 DOI: 10.1016/j.jhazmat.2022.128413] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 01/18/2022] [Accepted: 01/31/2022] [Indexed: 06/14/2023]
Abstract
Preparation of calibration curves is a critical step for large-scale quantification. However, this procedure is time-consuming, labor intensive. Herein, a novel isotopologue multipoint calibration (IMC) strategy, was proposed and demonstrated for the simultaneous quantitation of 120 pesticides and 83 veterinary drugs in surface water samples using Liquid Chromatography-High Resolution Mass Spectrometry (LC-HRMS). In this strategy, the natural isotopic distribution was used to generate external calibration curves, eliminating the need of analyst's adjustment and many sets of chemical standard solutions required in external calibration curves. Additionally, this strategy was comprehensively validated, and the results indicated this strategy had better performance in both accuracy and precision, fully meeting the requirements for the quantitative analysis. Interestingly, for the samples with high concentration beyond the upper limit of quantitation, the IMC strategy could avoid samples dilution by monitoring the less abundant isotopic channels. Furthermore, the IMC method was successfully applied in the surface water samples collected from Anhui province, China. Among which, sulfamethoxazole and imidacoprid were the main contributors. In conclusion, we present a promising LC-HRMS strategy for the accurate quantitation of small molecules, which has a potential application in food and environmental analysis.
Collapse
Affiliation(s)
- Feifei Sun
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China; Animal-derived Food Safety Innovation Team, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, People's Republic of China
| | - Haiguang Tan
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Mohamed F Abdallah
- Department of Food Technology, Food Safety and Health, Ghent University, Coupure Links 653, 9000 Ghent, Belgium
| | - Yanshen Li
- College of Life Science, Yantai University, Yantai, Shandong 264005, People's Republic of China
| | - Jinhui Zhou
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China
| | - Yi Li
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China.
| | - Shupeng Yang
- Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, People's Republic of China.
| |
Collapse
|
9
|
Visconti G, Olesti E, González-Ruiz V, Glauser G, Tonoli D, Lescuyer P, Vuilleumier N, Rudaz S. Internal calibration as an emerging approach for endogenous analyte quantification: Application to steroids. Talanta 2021; 240:123149. [PMID: 34954616 DOI: 10.1016/j.talanta.2021.123149] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 10/20/2021] [Accepted: 10/21/2021] [Indexed: 12/15/2022]
Abstract
The use of mass spectrometry methods with triple quadrupole instruments is well established for quantification. However, the preparation of calibration curves can be time-consuming and prone to analytical errors. In this study, an innovative internal calibration (IC) approach using a one-standard calibration with a stable isotope-labeled (SIL) standard version of the endogenous compound was developed. To ensure optimal quantitative performance, the following parameters were evaluated: the stability of the analyte-to-SIL response factor (RF), the chemical and isotopic purities of the SIL, and the instrumental reproducibility. Using six clinically important endogenous steroids and their respective SIL standards, we demonstrated that RFs obtained on different LC-MS platforms were consistent. The quantitative performance of the proposed approach was determined using quality control samples prepared in depleted serum, and showed both satisfactory precision (1.3%-12.4%) and trueness (77.5%-107.0%, with only 3 values outside ±30%). The developed method was then applied to human serum samples, and the results were similar to those obtained with the conventional quantification approach based on external calibration: the Passing-Bablok regression showed a proportional bias of 6.8% and a mean difference of -5.9% between the two methodologies. Finally, we showed that the naturally occurring isotopes of the SIL can be used to provide additional calibration points and increase the accuracy for analytes with low concentrations.
Collapse
Affiliation(s)
- Gioele Visconti
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland
| | - Eulalia Olesti
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| | - Víctor González-Ruiz
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| | - Gaëtan Glauser
- Neuchâtel Platform of Analytical Chemistry, University of Neuchâtel, Avenue de Bellevaux 51, 2000 Neuchâtel, Switzerland
| | - David Tonoli
- Division of Laboratory Medicine, Geneva University Hospitals (HUG), Geneva, Switzerland
| | - Pierre Lescuyer
- Division of Laboratory Medicine, Geneva University Hospitals (HUG), Geneva, Switzerland
| | - Nicolas Vuilleumier
- Division of Laboratory Medicine, Geneva University Hospitals (HUG), Geneva, Switzerland
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel-Servet 1, 1211, Geneva, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland.
| |
Collapse
|