1
|
Zhang E, Chen J, Li X, Luo L, Ma Y, Zhang Q, Wang X. An improved ultra-high performance liquid chromatography-tandem mass spectrometry method determining hispidulin and homoplantaginin in rat plasma and associated pharmacokinetic studies. ACTA CHROMATOGR 2022. [DOI: 10.1556/1326.2022.01082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Abstract
Flavonoids are the most abundant components in Salvia plebeia, with significant pharmacological antioxidant and hepatoprotective properties. Hispidulin and homoplantaginin are the main flavonoid components in S. Plebeia. In this study, we established an ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) to determine hispidulin and homoplantaginin in rat plasma samples, which were precipitated using acetonitrile-methanol (9:1, v/v). We used a UPLC HSS T3 (100 mm × 2.1 mm, 1.7 μm diameter) chromatographic column, an acetonitrile-water (containing 0.1% formic acid) mobile phase, and a gradient elution flow rate of 0.4 mL min−1 in an elution time of 4 min. We used electrospray ionization (ESI) detection in positive ion mode, and multiple reaction monitoring mode (MRM) for quantitative analysis: m/z 301 → 286 for hispidulin, m/z 463 → 301 for homoplantaginin, and m/z 465 → 303 for internal standard (IS). In pharmacokinetic studies, 24 rats were orally administered hispidulin and homoplantaginin (5 mg kg−1) and received sublingual intravenous injections (1 mg kg−1) at two different doses, four groups with six rats/group. Differences in hispidulin and homoplantaginin pharmacokinetics in rat plasma were evaluated. The calibration curve showed good linearity in the 0.5–1,000 ng mL−1 range, with r > 0.99. Precision, accuracy, recovery, matrix effects, and stability results all met standard biological sample detection requirements. Our pharmacokinetic studies showed hispidulin bioavailability was much higher than homoplantaginin at 17.8% and 0.1%, respectively.
Collapse
Affiliation(s)
- En Zhang
- Clinical Laboratory, Ningbo Medical Treatment Center Lihuili Hospital, Ningbo, China
| | - Junying Chen
- Analytical and Testing Center, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xia Li
- Clinical Laboratory, Ningbo Medical Treatment Center Lihuili Hospital, Ningbo, China
| | - Lvqi Luo
- Analytical and Testing Center, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Yizhe Ma
- Analytical and Testing Center, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Qingwei Zhang
- Shanghai Institute of Pharmaceutical Industry Co., Ltd., Shanghai, China
| | - Xianqin Wang
- Analytical and Testing Center, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
2
|
Cai X, Dai X, Li Z, Chen J, Wang X, Zhang M. An UPLC-MS/MS method for quantification of spiraeoside in mouse blood and its application to a pharmacokinetic and bioavailability study. ACTA CHROMATOGR 2022. [DOI: 10.1556/1326.2022.01061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Abstract
A simple, rapid, and sensitive method based on UPLC-MS/MS was developed to determine spiraeoside in mouse blood, and was applied to the pharmacokinetics and bioavailability of spiraeoside after mice after intravenous (a dose of 5 mg kg−1) and oral (a dose of 20 mg kg−1) administration. On HSS T3 column set at 40 °C, chromatographic separation was obtained with the mobile phase of acetonitrile and 0.1% formic acid using the gradient elution. Spiraeoside and internal standard (IS) were quantitatively analyzed using multiple reaction monitoring (MRM) mode in electrospray (ESI) positive interface. The MRM mode was monitoring the fragmentation of m/z 465.4→303.1 and m/z 451.3→ 289.2 for spironoside and IS, respectively. The results showed a good linear relationship was in the concentration range of 1–200 ng mL−1 (r > 0.998) and the lower limit of quantification (LLOQ) was 1.0 ng mL−1. The intra- and the inter-day precision (RSD%) of the method was within 14.0%, and the accuracy ranged from 90.0% to 115.0%. The extraction recovery of spriaeoside was better than 63.0%, and the matrix effects were in the range of 86%–98%. It also showed the half-life was short, and the absolute bioavailability was 4.0% in mice. Therefore, the established UPLC-MS/MS method was suitable for the pharmacokinetic and bioavailability study of spiraeoside in mice.
Collapse
Affiliation(s)
- Xiaojun Cai
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xiangyi Dai
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Zhou Li
- Wenzhou Customs Comprehensive Technical Service Center, Wenzhou, China
| | - Junying Chen
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xianqin Wang
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Meiling Zhang
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
3
|
Simultaneous Determination of Lamotrigine, Oxcarbazepine, Lacosamide, and Topiramate in Rat Plasma by Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry. Int J Anal Chem 2022; 2022:1838645. [PMID: 35321047 PMCID: PMC8938153 DOI: 10.1155/2022/1838645] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 02/24/2022] [Indexed: 12/21/2022] Open
Abstract
This study established an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method to study the pharmacokinetics of four antiepileptic drugs, lamotrigine, oxcarbazepine, lacosamide, and topiramate, in rats after oral administration. The gradient elution was performed on a UPLC HSS T3 (2.1 mm × 100 mm, 1.8 μm) column with acetonitrile-0.1% formic acid as the mobile phase at a flow rate of 0.4 mL/min. Protein precipitation by acetonitrile was adopted for plasma sample pretreatment. Electrospray- (ESI-) positive/negative ion switching and multiple reaction monitoring (MRM) modes were adopted for ion quantitative determination of antiepileptic drugs. UPLC-MS/MS detection and Drug and Statistics (DAS) software fitting were performed to blood samples collected from rats after oral administration of lamotrigine, oxcarbazepine, lacosamide, and topiramate (5 mg/kg). All drugs examined showed linearity within 5–5000 ng/ml (R2 > 0.9987), the intraday accuracy was within 92%–108%, and the interday accuracy was within 93%–109%. The relative standard deviations (RSD) of intraday and interday were less than 15%. The matrix effect was within 91%–105%, and the recovery was better than 88%. The established UPLC-MS/MS method was successfully applied to the pharmacokinetic study of lamotrigine, oxcarbazepine, lacosamide, and topiramate in rats.
Collapse
|
4
|
Chen M, Jin J, Ji X, Chang K, Li J, Zhao L. Pharmacokinetics, bioavailability and tissue distribution of chitobiose and chitotriose in rats. BIORESOUR BIOPROCESS 2022; 9:13. [PMID: 38647841 PMCID: PMC10991139 DOI: 10.1186/s40643-022-00500-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Accepted: 01/22/2022] [Indexed: 11/10/2022] Open
Abstract
Chitooligosaccharides (COSs) have various physiological activities and broad application prospects; however, their pharmacokinetics and tissue distribution remain unclear. In this study, a sensitive and selective ultra-performance liquid chromatography-mass spectrometry (UPLC-MS) method for determining chitobiose (COS 2) and chitotriose (COS 3) in rat serum and tissues was developed. This method was successfully validated based on FDA guidelines in terms of selectivity, calibration curves (lower limit of quantification was 0.002 µg/mL for COS 2 and 0.02 µg/mL for COS 3), precision (intra-day relative standard deviation of 0.04%-3.55% and inter-day relative standard deviation of 1.94%-11.63%), accuracy (intra-day relative error of - 1.81%-11.06% and inter-day relative error of - 9.41%-8.63%), matrix effects, recovery (97.10%-101.29%), stability, dilution integrity, and carry-over effects. Then, the method was successfully applied to the pharmacokinetics and tissue distribution study of COS 2 and COS 3 after intragastric and intravenous administration. After intragastric administration, COS 2 and COS 3 were rapidly absorbed, reached peak concentrations in the serum after approximately 0.45 h, and showed rapid elimination with clearances greater than 18.82 L/h/kg and half-lives lower than 6 h. The absolute oral bioavailability of COS 2 and COS 3 was 0.32%-0.52%. COS 2 and COS 3 were widely distributed in Wistar rat tissues and could penetrated the blood-brain barrier without tissue accumulation.
Collapse
Affiliation(s)
- Mai Chen
- School of Biotechnology, State Key Laboratory of Bioreactor Engineering, R&D Center of Separation and Extraction Technology in Fermentation Industry, East China University of Science and Technology, Shanghai, 200237, China
| | - Jiayang Jin
- School of Biotechnology, State Key Laboratory of Bioreactor Engineering, R&D Center of Separation and Extraction Technology in Fermentation Industry, East China University of Science and Technology, Shanghai, 200237, China
| | - Xiaoguo Ji
- School of Biotechnology, State Key Laboratory of Bioreactor Engineering, R&D Center of Separation and Extraction Technology in Fermentation Industry, East China University of Science and Technology, Shanghai, 200237, China
| | - Kunlin Chang
- School of Biotechnology, State Key Laboratory of Bioreactor Engineering, R&D Center of Separation and Extraction Technology in Fermentation Industry, East China University of Science and Technology, Shanghai, 200237, China
| | - Juan Li
- Department of Nutrition, Chang-Zheng Hospital, Naval Medical University, Shanghai, 200003, China.
| | - Liming Zhao
- School of Biotechnology, State Key Laboratory of Bioreactor Engineering, R&D Center of Separation and Extraction Technology in Fermentation Industry, East China University of Science and Technology, Shanghai, 200237, China.
- Shanghai Collaborative Innovation Center for Biomanufacturing Technology (SCICBT), Shanghai, 200237, China.
| |
Collapse
|
5
|
Yu Z, Chen F, Jin Y, Zhou M, Wang X, Shen X. Determination of oroxin A, oroxin B, oroxylin A, oroxyloside, chrysin, chrysin 7-O-beta-gentiobioside, and guaijaverin in mouse blood by UPLC-MS/MS and its application to pharmacokinetics. ACTA CHROMATOGR 2021. [DOI: 10.1556/1326.2021.00963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Abstract
In this study, a UPLC-MS/MS method was developed to measure the concentrations of the flavonoids oroxin A, oroxin B, oroxylin A, oroxyloside, chrysin, chrysin 7-O-beta-gentiobioside, and guaijaverin in the blank mouse blood, and the method was then used in the measurement of the pharmacokinetics of the compounds in mice. Oroxin A, oroxin B, oroxylin A, oroxyloside, chrysin, chrysin 7-O-beta-gentiobioside, and guaijaverin were administered intravenously at a dose of 5 mg kg−1, and the mouse blood (20 μL) was withdrawn from the caudal vein 0.08333, 0.25, 0.5, 1, 2, 4, 6, 8, and 10 h after administration. The mobile phase used for chromatographic separation by gradient elution was composed of acetonitrile and water (0.1% formic acid). The analytes were detected by operating in electrospray ionization (ESI) positive-ion mode using multiple reactions monitoring (MRM). The intra-day and inter-day accuracy ranged from 86.2 to 109.3%, the intra-day precision was less than 14%, and the inter-day precision was less than 15%. The matrix effect ranged from 85.3 to 111.3%, and the recovery of the analytes after protein precipitation were all above 78.2%. This method had the advantages of high sensitivity, accuracy, and recovery, and it had excellent selectivity, which enabled it to be applied to measuring the pharmacokinetics of the analytes in mice.
Collapse
Affiliation(s)
- Zheng Yu
- 1 Analytical and Testing Centre, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Fan Chen
- 2 Ruian People’s Hospital, The Third Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Yinan Jin
- 1 Analytical and Testing Centre, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Minyue Zhou
- 1 Analytical and Testing Centre, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xianqin Wang
- 1 Analytical and Testing Centre, School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xiuwei Shen
- 2 Ruian People’s Hospital, The Third Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
6
|
Lin C, Song D, Jiang H, Luo L, Bao X, Yu X, Ma J, Wang X, Jiang X. Determination of eugenitin in mouse blood by ultra-performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study. ACTA CHROMATOGR 2021. [DOI: 10.1556/1326.2021.00937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Abstract
Eugenitin is a non-volatile chromone derivative which is always found in dried flower buds of Syzygium aromaticum L. (Merr.) & L.M. Perry. Until now, there were no reports about the pharmacokinetics of eugenitin in biological fluids. A UPLC-MS/MS method developed to determine eugenitin in mouse blood. The blood samples were prepared by protein precipitation with acetonitrile. Chrysin (internal standard, IS) and eugenitin were gradient eluted by mobile phase of acetonitrile and water (0.1% formic acid) in a BEH C18 column. The multiple reaction monitoring (MRM) of m/z 221.1→206.0 for eugenitin and m/z 255.1→152.9 for IS with an electrospray ionization (ESI) source was used for quantitative detection. The calibration curve ranged from 0.5 to 500 ng/mL (r > 0.995). The accuracy ranged from 98 to 113%, the precision was less than 12%, and the matrix effect was between 86 and 94%, the recovery was better than 81%. The developed method was successfully used for pharmacokinetics of eugenitin in mice after intravenous (5 mg/kg) and oral (20 mg/kg) administration, and the absolute availability of eugenitin was 12%.
Collapse
Affiliation(s)
- Chongliang Lin
- Department of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Dezhen Song
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Haodong Jiang
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Lvqi Luo
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xi Bao
- Department of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Xiaomin Yu
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Jianshe Ma
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xianqin Wang
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xiajuan Jiang
- Department of Pharmacy, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| |
Collapse
|