1
|
Bartlett MG. Current state of hydrophilic interaction liquid chromatography of oligonucleotides. J Chromatogr A 2024; 1736:465378. [PMID: 39293276 DOI: 10.1016/j.chroma.2024.465378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 09/11/2024] [Accepted: 09/13/2024] [Indexed: 09/20/2024]
Abstract
There has been a significant increase in the use of hydrophilic interaction liquid chromatography (HILIC) to separate oligonucleotides. This rise in the use of HILIC has correlated to the increasing success of oligonucleotides as therapeutic treatments and reagents in biomedical research. As more scientists need to routinely analyze oligonucleotides in addition to small molecules, peptides, and proteins using the same analytical instruments, it becomes difficult to use traditional types of analyses such as ion-pair reversed-phase chromatography. This increased use has led to new approaches that have improved the utility of HILIC to the point where it has become a legitimate alternative approach to ion-pair reversed-phase chromatography. This review highlights recent advances in HILIC separations of oligonucleotides with a focus on the underlying mechanisms of action. While HILIC has made significant gains in performance, there still remain challenges, which if properly addressed will continue to propel this approach forward.
Collapse
Affiliation(s)
- Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, GA 30602, USA.
| |
Collapse
|
2
|
Parr MK, Keiler AM. Oligonucleotide therapeutics in sports? An antidoping perspective. Arch Pharm (Weinheim) 2024:e2400404. [PMID: 39449227 DOI: 10.1002/ardp.202400404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 09/26/2024] [Accepted: 09/30/2024] [Indexed: 10/26/2024]
Abstract
Within the last two decades, the European Medicines Agency and the US Food and Drug Administration have approved several gene therapies. One category is oligonucleotide therapeutics, which allow for the regulation of the expression of target genes. Besides already approved therapeutics, there are several preclinical and clinical trials ongoing. The World Anti-Doping Agency prohibits the use of "nucleic acids or nucleic acid analogs that may alter genome sequences and/or alter gene expression by any mechanism" as a nonspecified method at all times. Hence, the administration of nucleic acids or analogs by athletes would cause an Anti-Doping Rule Violation. Herein, we discuss types of oligonucleotide therapeutics, their potential to be misused in sports, and considerations to sample preparation and mass spectrometric approaches with regard to antidoping analysis.
Collapse
Affiliation(s)
- Maria K Parr
- Institute of Pharmacy, Pharmaceutical and Medicinal Chemistry, Freie Universität Berlin, Berlin, Germany
| | - Annekathrin M Keiler
- Institute of Doping Analysis & Sports Biochemistry, Kreischa, Germany
- Environmental Monitoring & Endocrinology, Faculty of Biology, Technische Universität Dresden, Dresden, Germany
| |
Collapse
|
3
|
Tiambeng TN, Yan Y, Patel SK, Cotham VC, Wang S, Li N. Characterization of adeno-associated virus capsid proteins using denaturing size-exclusion chromatography coupled with mass spectrometry. J Pharm Biomed Anal 2024; 253:116524. [PMID: 39442445 DOI: 10.1016/j.jpba.2024.116524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 09/26/2024] [Accepted: 10/13/2024] [Indexed: 10/25/2024]
Abstract
Recombinant adeno-associated viruses (AAVs) are a highly effective platform for gene delivery for the treatment of many human diseases. Characterization of AAV viral protein attributes (VP), such as serotype identity, VP stoichiometry, and VP post-translational modifications, is essential to ensure product and process consistency. While size-exclusion chromatography (SEC) coupled with mass spectrometry (MS) is commonly used in the biopharmaceutical industry for analyzing protein therapeutics, its application to intact AAV VP components has not gained traction, presumably due to difficulties in achieving adequate resolution of VP(1-3) monomers. Herein, we describe the development of a denaturing SEC method and optimization of SEC parameters, including stationary phase pore size, column temperature, and mobile phase composition, to achieve effective chromatographic separation of VP(1-3). We demonstrate that an optimized dSEC-MS method featuring MS-compatible formic acid, can effectively separate VP(1-3) across AAV1, 2, 5, 6, 8, and 9 serotypes using a single column and mobile phase condition. A case study was included to showcase successful application of the dSEC-MS method in analyzing changes across different AAV production processes, yielding similar conclusions to an orthogonal approach, such as hydrophilic interaction chromatography (HILIC)- MS. Additionally, dSEC integrated with fluorescence (FLR) and ultraviolet (UV) detection can be used to semi-quantitatively identify both AAV DNA and VP components from empty and full AAV samples. Overall, this robust and MS-friendly methodological advancement could greatly streamline the development and analytical quality control processes for AAV-based gene therapies, providing a highly sensitive method for intact VP characterization.
Collapse
Affiliation(s)
- Timothy N Tiambeng
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591-6707, USA
| | - Yuetian Yan
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591-6707, USA.
| | - Shailin K Patel
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591-6707, USA
| | - Victoria C Cotham
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591-6707, USA
| | - Shunhai Wang
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591-6707, USA.
| | - Ning Li
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591-6707, USA
| |
Collapse
|
4
|
Guimaraes GJ, Kim J, Bartlett MG. Characterization of mRNA therapeutics. MASS SPECTROMETRY REVIEWS 2024; 43:1066-1090. [PMID: 37401740 DOI: 10.1002/mas.21856] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 04/25/2023] [Accepted: 05/17/2023] [Indexed: 07/05/2023]
Abstract
Therapeutic messenger RNAs (mRNAs) have emerged as powerful tools in the treatment of complex diseases, especially for conditions that lack efficacious treatment. The successful application of this modality can be attributed to its ability to encode entire proteins. While the large nature of these molecules has supported their success as therapeutics, its extended size creates several analytical challenges. To further support therapeutic mRNA development and its deployment in clinical trials, appropriate methods to support their characterization must be developed. In this review, we describe current analytical methods that have been used in the characterization of RNA quality, identity, and integrity. Advantages and limitations from several analytical techniques ranging from gel electrophoresis to liquid chromatography-mass spectrometry and from shotgun sequencing to intact mass measurements are discussed. We comprehensively describe the application of analytical methods in the measurements of capping efficiency, poly A tail analysis, as well as their applicability in stability studies.
Collapse
Affiliation(s)
- Guilherme J Guimaraes
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia, USA
| | - Jaeah Kim
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia, USA
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, Athens, Georgia, USA
| |
Collapse
|
5
|
Herbert C, Valesyan S, Kist J, Limbach PA. Analysis of RNA and Its Modifications. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2024; 17:47-68. [PMID: 38594935 DOI: 10.1146/annurev-anchem-061622-125954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Ribonucleic acids (RNAs) are key biomolecules responsible for the transmission of genetic information, the synthesis of proteins, and modulation of many biochemical processes. They are also often the key components of viruses. Synthetic RNAs or oligoribonucleotides are becoming more widely used as therapeutics. In many cases, RNAs will be chemically modified, either naturally via enzymatic systems within a cell or intentionally during their synthesis. Analytical methods to detect, sequence, identify, and quantify RNA and its modifications have demands that far exceed requirements found in the DNA realm. Two complementary platforms have demonstrated their value and utility for the characterization of RNA and its modifications: mass spectrometry and next-generation sequencing. This review highlights recent advances in both platforms, examines their relative strengths and weaknesses, and explores some alternative approaches that lie at the horizon.
Collapse
Affiliation(s)
- Cassandra Herbert
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, Cincinnati, Ohio, USA;
| | - Satenik Valesyan
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, Cincinnati, Ohio, USA;
| | - Jennifer Kist
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, Cincinnati, Ohio, USA;
| | - Patrick A Limbach
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, Cincinnati, Ohio, USA;
| |
Collapse
|
6
|
Wageed M, Mahdy HM, Kalaba MH, Kelany MA, Soliman M. Development of LC-MS/MS analytical method for the rapid determination of Diquat in water and beverages. Food Chem 2024; 438:137869. [PMID: 37992601 DOI: 10.1016/j.foodchem.2023.137869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Revised: 10/18/2023] [Accepted: 10/24/2023] [Indexed: 11/24/2023]
Abstract
This study aimed to develop simple, fast, and sensitive methods for the determination of diquat (DQ) in various matrices such as water and beverages. For water, direct injection was tested first, however, the sensitivity of the incurred samples were too low and couldn't possibly achieve the targeted limit of quantification. Hence, dilution with "weaker" injection solvents were tested, and the final conditions involved the dilution of water with acetonitrile (0.4 % ammonium hydroxide) which increased the sensitivity by more than ten times. Nevertheless, the beverages samples needed further treatment to achieve acceptable spiked recovery. The final conditions involved extraction using the aforementioned solvent, followed by heating and partitioning. Both of the methods satisfied the validation requirements, with an average recovery ranging from 85.9 to115 % and associated relative standard deviation (RSD %) within the range 3-8. Further applications on real samples were done to test the levels of contamination.
Collapse
Affiliation(s)
- Mohamed Wageed
- Agricultural Research Center, Central Laboratory of Residue Analysis of Pesticides and Heavy Metals in Foods (QCAP), Ministry of Agriculture and Land Reclamation, Giza 12311, Egypt.
| | - Hesham M Mahdy
- Botany and Microbiology Department, Faculty of Science, Al-Azhar University, Cairo 11884, Egypt
| | - Mohamed H Kalaba
- Botany and Microbiology Department, Faculty of Science, Al-Azhar University, Cairo 11884, Egypt
| | - Mohamed A Kelany
- Agricultural Research Center, Central Laboratory of Residue Analysis of Pesticides and Heavy Metals in Foods (QCAP), Ministry of Agriculture and Land Reclamation, Giza 12311, Egypt
| | - Mostafa Soliman
- Agricultural Research Center, Central Laboratory of Residue Analysis of Pesticides and Heavy Metals in Foods (QCAP), Ministry of Agriculture and Land Reclamation, Giza 12311, Egypt
| |
Collapse
|
7
|
Vosáhlová Z, Kalíková K, Gilar M, Szymarek J, Mazurkiewicz-Bełdzińska M, Studzińska S. Hydrophilic interaction liquid chromatography with mass spectrometry for the separation and identification of antisense oligonucleotides impurities and nusinersen metabolites. J Chromatogr A 2024; 1713:464535. [PMID: 38039623 DOI: 10.1016/j.chroma.2023.464535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 11/24/2023] [Accepted: 11/25/2023] [Indexed: 12/03/2023]
Abstract
With the development of therapeutic oligonucleotides for antisense and gene therapies, the demand for analytical methods also increases. For the analysis of complex samples, for example plasma samples, where the use of mass detection is essential, hydrophilic interaction liquid chromatography is a suitable choice. The aim of the present work was to develop a method for separation and identification of the oligonucleotide impurities and metabolites by hydrophilic interaction liquid chromatography. First of all, the effects of different chromatographic conditions (e.g. pH of the aqueous part of the mobile phase, buffer concentration, column temperature) on the retention and separation of phosphorothioate oligonucleotides standards on the amide stationary phase were investigated. A set of model oligonucleotides containing a fully modified 21mer and its typical impurities (shortmers and oligonucleotides with different number of thiophosphate modifications) was used. The results showed that the concentration of the salt in the mobile phase as well as its pH, are the most influential parameters with regard to peak shape and separation. The knowledge gained was applied to the analysis of an unpurified 18mer oligonucleotides, analogues of the drug nusinersen used for the treatment of spinal muscular atrophy. The successful separation and identification of twenty-six and twenty-eight impurities was performed with the developed HILIC method. The method was applied to analysis of nusinersen metabolites of serum samples of patients treated with Spinraza.
Collapse
Affiliation(s)
- Zuzana Vosáhlová
- Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, 12800, Prague, Czech Republic
| | - Květa Kalíková
- Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, 12800, Prague, Czech Republic.
| | - Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA
| | - Jakub Szymarek
- Department of Developmental Neurology, Medical University of Gdansk, 7 Dębinki Str., PL-80-952, Gdańsk, Poland
| | | | - Sylwia Studzińska
- Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, 12800, Prague, Czech Republic; Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin Str., PL-87-100 Toruń, Poland; Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University in Toruń, 4 Wilenska St., 87-100 Toruń, Poland.
| |
Collapse
|
8
|
Gilar M, Koshel BM, Birdsall RE. Ion-pair reversed-phase and hydrophilic interaction chromatography methods for analysis of phosphorothioate oligonucleotides. J Chromatogr A 2023; 1712:464475. [PMID: 39491274 DOI: 10.1016/j.chroma.2023.464475] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 10/23/2023] [Accepted: 10/25/2023] [Indexed: 11/05/2024]
Abstract
In this study we investigated the separation of a 25 mer fully phosphorothioated oligonucleotide from its truncated n-1 (24 mer) species and selected phosphodiester 25 mer impurities using ion-pair reversed-phase chromatography. The hydrophobicity of ion-pairing agents (alkylamines) impacts n-1 separation selectivity. 25 mer impurities with single and double phosphodiester bonds eluted prior to the parent phosphorothioate oligonucleotide in the same region as 24 mer impurities, which complicated the chromatographic separation. An alternative technique, hydrophilic interaction chromatography, provided a different retention pattern; 24 mer n-1 impurities eluted prior to the 25 mer, while the phosphodiester impurities eluted after the full-length oligonucleotide. This enabled an improved chromatographic separation of the truncated and phosphodiester impurities from the phosphorothioate oligonucleotide of interest.
Collapse
Affiliation(s)
- Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, MA 01757, USA.
| | | | | |
Collapse
|
9
|
Gilar M, Doneanu C, Gaye MM. Liquid Chromatography Methods for Analysis of mRNA Poly(A) Tail Length and Heterogeneity. Anal Chem 2023; 95:14308-14316. [PMID: 37696042 PMCID: PMC10535021 DOI: 10.1021/acs.analchem.3c02552] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 08/28/2023] [Indexed: 09/13/2023]
Abstract
Messenger RNA (mRNA) is a new class of therapeutic compounds. The current advances in mRNA technology require the development of efficient analytical methods. In this work, we describe the development of several methods for measurement of mRNA poly(A) tail length and heterogeneity. Poly(A) tail was first cleaved from mRNA with the RNase T1 enzyme. The average length of a liberated poly(A) tail was analyzed with the size exclusion chromatography method. Size heterogeneity of the poly(A) tail was estimated with high-resolution ion-pair reversed phase liquid chromatography (IP RP LC). The IP RP LC method provides resolution of poly(A) tail oligonucleotide variants up to 150 nucleotide long. Both methods use a robust ultraviolet detection suitable for mRNA analysis in quality control laboratories. The results were confirmed by the LC-mass spectrometry (LC MS) analysis of the same mRNA sample. The poly(A) tail length and heterogeneity results were in good agreement.
Collapse
Affiliation(s)
- Martin Gilar
- Separations
R&D, Waters Corporation, Milford, Massachusetts 01757, United States
| | - Catalin Doneanu
- Discovery
and Development, Waters Corporation, Milford, Massachusetts 01757, United States
| | - Maissa M. Gaye
- Consumables
Research, Waters Corporation, Milford, Massachusetts 01757, United States
| |
Collapse
|
10
|
Managing nonspecific adsorption to liquid chromatography hardware: A review. Anal Chim Acta 2023; 1250:340994. [PMID: 36898813 DOI: 10.1016/j.aca.2023.340994] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 02/16/2023] [Accepted: 02/17/2023] [Indexed: 02/19/2023]
Abstract
The choice of alternative materials over stainless steel hardware in the construction of liquid chromatography systems has unveiled the degree to which nonspecific adsorption impacts the reproducibility of LC methods. Some of the major contributors to nonspecific adsorption losses are charged metallic surfaces and leached metallic impurities, that may interact with the analyte and result in analyte loss and overall poor chromatographic performance. In this review, we describe several mitigation strategies available to chromatographers to minimize nonspecific adsorption to chromatographic systems. Alternative surfaces to stainless steel such as titanium, PEEK, and hybrid surface technologies are discussed. Furthermore, mobile phase additives used to prevent metal ion-analyte interactions are reviewed. Nonspecific adsorption of analytes is not reserved to metallic surfaces, as analytes may adsorb to the surfaces of filters, tubes, and pipette tips during sample preparation. Identifying the source of nonspecific interactions is paramount, as mitigation strategies may differ depending on what stage nonspecific losses are taking place. With this in mind, we discuss diagnostic methods that may help the chromatographer to differentiate losses resulting from sample preparation, and losses during LC runs.
Collapse
|
11
|
Guimaraes GJ, Leach FE, Bartlett MG. Microflow Liquid Chromatography – Multi-Emitter Nanoelectrospray Mass Spectrometry of Oligonucleotides. J Chromatogr A 2023; 1696:463976. [PMID: 37054634 DOI: 10.1016/j.chroma.2023.463976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/04/2023] [Accepted: 04/05/2023] [Indexed: 04/08/2023]
Abstract
While the most sensitive LC-MS methods for oligonucleotide analysis contain ion-pairs in the mobile phase, these modifiers have been associated with instrument contamination and ion suppression. Typically, entire LC-MS systems are reserved for oligonucleotide LC-MS when using ion-pairing buffers. To overcome these limitations, numerous HILIC methods, liberated from ion-pairs, have been recently developed. Since ion-pairs play a role in analyte desorption from ESI droplets, their removal from mobile phases tend to impact method sensitivity. An effective way to recover MS sensitivity is to reduce the LC flow rate and therefore reduce ESI droplet size. With a focus on MS sensitivity, this study investigates the applicability of a microflow LC- nanoelectrospray MS platform in oligonucleotide ion-pair RP and HILIC LC-MS methods. The platform is effective and substantially increased the MS sensitivity of HILIC methods. Furthermore, LC method development for both types of separations provide insight into microflow chromatography of oligonucleotides, an under investigated chromatographic scale.
Collapse
|
12
|
Roussis SG, Rentel C. Exploring the use of the desirability function to optimize the separation of oligonucleotide impurities by ion pair-RP LCMS. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1220:123666. [PMID: 36921438 DOI: 10.1016/j.jchromb.2023.123666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 03/03/2023] [Accepted: 03/06/2023] [Indexed: 03/11/2023]
Abstract
The use of small alkyl amines as ion pair reagents permits enhanced separation of impurities of phosphate diester oligonucleotides, which can be beneficial to quality control applications, and aid elucidation of the mechanisms of impurity formation. In general, however, separation of the individual components that comprise the majority of oligonucleotide impurities requires development of several independent chromatographic methods. Ideally, a single method capable of separating the individual components of all impurity classes would be developed. The mathematical concept of the desirability function has been explored here for its ability to determine the combination of experimental factors that result in a single, globally optimized chromatographic method. The optimized mobile phase, consisting of 1 mM propylamine (PA), 30 mM ammonium bicarbonate (ABC), and 1 mM octanoic acid (C8A), produced excellent agreement between measured and predicted peak resolution values for a set of n - 1 impurities. The relative importance of the mobile phase constituents on the mechanism of separation has been discussed. The approach holds great promise for the improved separation of components in complex chromatographic systems.
Collapse
Affiliation(s)
| | - Claus Rentel
- Ionis Pharmaceuticals, Carlsbad, CA 92010, United States
| |
Collapse
|
13
|
Development and multicenter validation of an LC–MS-based bioanalytical method for antisense therapeutics. Bioanalysis 2022; 14:1213-1227. [DOI: 10.4155/bio-2022-0126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background: Many bioanalytical methods for antisense oligonucleotides (ASOs) using LC–MS have been reported. However, no data have been available on the reproducibility and robustness of a single bioanalytical method for ASOs. As such, in the current study, we evaluated the reproducibility and robustness of LC–MS-based bioanalytical methods for ASOs in multiple laboratories. Methods/Results: Seven independent laboratories were included in this study. Mipomersen was measured by ion-pairing LC–MS (IP-LC–MS) as a model ASO using different LC–MS. The validation results of calibration curve, accuracy, precision and selectivity met the criteria of conventional bioanalytical method validation guidelines using LC/GC–MS for drugs in all laboratories. Meanwhile, carryover (>20%) was detected in three laboratories. Conclusion: We first demonstrated the multicenter-validated IP-LC–MS bioanalytical method for ASOs. Our data showed that the method was sensitive, robust and reproducible. However, the occurrence of carryover should be carefully monitored in its future application.
Collapse
|
14
|
Metabolic profiling workflow for cell extracts by targeted hydrophilic interaction liquid chromatography-tandem mass spectrometry. J Chromatogr A 2022; 1684:463556. [DOI: 10.1016/j.chroma.2022.463556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 10/04/2022] [Accepted: 10/07/2022] [Indexed: 11/22/2022]
|
15
|
Lardeux H, Goyon A, Zhang K, Nguyen JM, Lauber MA, Guillarme D, D'Atri V. The impact of low adsorption surfaces for the analysis of DNA and RNA oligonucleotides. J Chromatogr A 2022; 1677:463324. [PMID: 35858489 DOI: 10.1016/j.chroma.2022.463324] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 07/07/2022] [Accepted: 07/08/2022] [Indexed: 12/20/2022]
Abstract
As interest in oligonucleotide (ON) therapeutics is increasing, there is a need to develop suitable analytical methods able to properly analyze those molecules. However, an issue exists in the adsorption of ONs on different parts of the instrumentation during their analysis. The goal of the present paper was to comprehensively evaluate various types of bioinert materials used in ion-pairing reversed-phase (IP-RPLC) and hydrophilic interaction chromatography (HILIC) to mitigate this issue for 15- to 100-mer DNA and RNA oligonucleotides. The whole sample flow path was considered under both conditions, including chromatographic columns, ultra-high-performance liquid chromatography (UHPLC) system, and ultraviolet (UV) flow cell. It was found that a negligible amount of non-specific adsorption might be attributable to the chromatographic instrumentation. However, the flow cell of a detector should be carefully subjected to sample-based conditioning, as the material used in the UV flow cell was found to significantly impact the peak shapes of the largest ONs (60- to 100-mer). Most importantly, we found that the choice of column hardware had the most significant impact on the extent of non-specific adsorption. Depending on the material used for the column walls and frits, adsorption can be more or less pronounced. It was proved that any type of bioinert RPLC/HILIC column hardware offered some clear benefits in terms of adsorption in comparison to their stainless-steel counterparts. Finally, the evaluation of a large set of ONs was performed, including a DNA duplex and DNA or RNA ONs having different base composition, furanose sugar, and modifications occurring at the phosphate linkage or at the sugar moiety. This work represents an important advance in understanding the overall ON adsorption, and it helps to define the best combination of materials when analyzing a wide range of unmodified and modified 20-mer DNA and RNA ONs.
Collapse
Affiliation(s)
- Honorine Lardeux
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland
| | - Alexandre Goyon
- Small Molecule Pharmaceutical Sciences, Genentech Inc., DNA Way, South San Francisco, CA 94080, USA
| | - Kelly Zhang
- Small Molecule Pharmaceutical Sciences, Genentech Inc., DNA Way, South San Francisco, CA 94080, USA
| | | | | | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland
| | - Valentina D'Atri
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland.
| |
Collapse
|
16
|
Walter TH, Alden BA, Belanger JL, Berthelette K, Boissel C, DeLano M, Kizekai L, Nguyen JM, Shiner SJ. Modifying the Metal Surfaces in HPLC Systems and Columns to Prevent Analyte Adsorption and Other Deleterious Effects. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.pm7270x6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Interactions of certain analytes with metal surfaces in high performance liquid chromatography (HPLC) instruments and columns cause a range of deleterious effects, including peak broadening and tailing, low peak areas, and the formation of new peaks due to chemical reactions. To mitigate these effects, we have developed a novel surface modification technology in which a hybrid organic/inorganic surface based on an ethylene-bridged siloxane chemistry is applied to the metal components in HPLC instruments and columns. We demonstrate the impact of this technology on peak symmetry, peak area, and injection-to-injection and column-to-column reproducibility for several metal-sensitive analytes. We also show an example of the mitigation of an on-column oxidation reaction. A variant of this technology has recently been developed for size-exclusion chromatography of proteins. An example is shown demonstrating the use of this variant applied to size-exclusion columns for the separation of a monoclonal antibody monomer and higher molecular weight species. Together, these results highlight the importance of preventing interactions of analytes with metal surfaces in HPLC in order to achieve accurate and precise results.
Collapse
|
17
|
Morreel K, t’Kindt R, Debyser G, Jonckheere S, Sandra P. Diving into the Structural Details of In Vitro Transcribed mRNA Using Liquid Chromatography–Mass Spectrometry-Based Oligonucleotide Profiling. LCGC EUROPE 2022. [DOI: 10.56530/lcgc.eu.jk3969w4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
The production process of in vitro transcribed messenger RNA (IVT-mRNA)-based vaccines has matured in recent years, partly due to the fight against infectious diseases such as COVID-19. One key to success has been the use of modified, next to canonical, nucleotides and the efficient addition of a Cap-structure and poly A tail to the 5’ and 3’ end, respectively, of this massive biomolecule. These important features affect mRNA stability and impact translation efficiency, consequently boosting the optimization and implementation of liquid chromatography–mass spectrometry (LC–MS)-based oligonucleotide profiling methods for their characterization. This article will provide an overview of these LC–MS methods at a fundamental and application level. It will be shown how LC–MS is implemented in mRNA-based vaccine analysis to determine the capping efficiency and the poly A tail length, and how it allows, via RNA mapping, (i) to determine the mRNA sequence, (ii) to screen the fidelity of the manufactured modifications, and (iii) to identify and quantify unwanted modifications resulting from manufacturing or storage, and sequence variants resulting from mutation or transcription errors.
Collapse
|
18
|
Hughes CJ, Gethings LA, Wilson ID, Plumb RS. Access to the Phospho-proteome via the Mitigation of Peptide-Metal Interactions. J Chromatogr A 2022; 1673:463024. [DOI: 10.1016/j.chroma.2022.463024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 03/21/2022] [Accepted: 04/03/2022] [Indexed: 10/18/2022]
|
19
|
Optimizing test approaches for the detection of exposed metal surfaces within a chromatographic flow path. J Chromatogr A 2022; 1666:462855. [DOI: 10.1016/j.chroma.2022.462855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 01/25/2022] [Accepted: 01/25/2022] [Indexed: 11/18/2022]
|