1
|
Comparison study of three laparoscopic ligation procedures for pediatric inguinal hernia: a multicenter cohort of 5523 cases. Hernia 2022; 26:1659-1667. [PMID: 35504975 DOI: 10.1007/s10029-022-02600-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 03/11/2022] [Indexed: 11/04/2022]
Abstract
PURPOSE Single-site laparoscopic percutaneous extraperitoneal ligation (SLPEL) for pediatric inguinal hernia has gained popularity worldwide. However, complications associated with extraperitoneal knotting are not rare. This study evaluated the effectiveness of a modified SLPEL (M-SLPEL) to decrease adverse events associated with ligation knotting by comparing it with two other methods: classical SLPEL (C-SLPEL) and intracorporeal purse-string suturing (IPS). METHODS A multicenter retrospective comparative study was conducted among 5523 pediatric inguinal hernia patients. Cases were divided into three groups according to the surgical procedure: the M-SLPEL, C-SLPEL, and IPS groups. Data describing the clinical characteristics, operative time, and complications were collected. RESULTS All procedures were performed uneventfully. There were no significant differences in the age at operation (mean 2.62 ± 1.38 years). The operative time was shorter in the M-SLPEL group both for unilateral hernias (12.5 ± 1.8 min in C-SLPEL, 11.7 ± 1.3 min in M-SLPEL, and 17.6 ± 2.9 min in IPS) and for bilateral hernias (15.1 ± 2.1 min, 14.6 ± 1.7 min, and 23.9 ± 2.3 min, respectively). The overall incidence of adverse events in the inguinal region was 0% for M-SLPEL, 2.2% for C-SLPEL, and 0.5% for IPS. All patients were followed up for 12-93 months (mean 54 months). Recurrence occurred in 8 cases in the C-SLPEL group, 1 case in the M-SLPEL group, and 8 cases in the IPS group, with no significance between groups. No scrotal hematoma, testicular atrophy, or iatrogenic cryptorchidism occurred in any group. CONCLUSION The M-SLPEL procedure has time-consumption efficiency equivalent to that of C-SLPEL and even fewer adverse events in the inguinal region than IPS and C-SLPEL.
Collapse
|
2
|
Ramot Y, Rousselle S, Steiner M, Lavie Y, Ezov N, Nyska A. Safety and Performance Evaluation of Su2ura Approximation, a New Suturing Device, in Pigs. Toxicol Pathol 2021; 50:211-217. [DOI: 10.1177/01926233211067960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
One of the challenging aspects of minimal invasive surgery (MIS) is intracorporal suturing, which can be significantly time-consuming. Therefore, there is a rising need for devices that can facilitate the suturing procedure in MIS. Su2ura Approximation Device (Su2ura Approximation) is a novel device developed to utilize the insertion of anchors threaded with stitches to allow a single action placement of a suture. The objective of this study was to evaluate the long-term safety and tissue approximation of Su2ura Approximation in comparison to Endo Stitch + Surgidac sutures in female domestic pigs. All incision sites were successfully closed by both methods. Firm consolidation within and around the incision site was noted in several animals in both treatment groups, which corresponded histopathologically to islands of ectopic cartilage or bone spicules within the fibrotic scar. These changes reflect heterotopic ossification that is commonly seen in the healing of abdominal operation sites in pigs. No other abnormal findings were observed throughout the study period. In conclusion, the use of Su2ura Approximation under the present experimental conditions revealed no safety concerns.
Collapse
Affiliation(s)
- Yuval Ramot
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel
- Department of Dermatology, Hadassah Medical Center, Jerusalem, Israel
| | | | | | | | - Nati Ezov
- Envigo CRS (Israel), Ness Ziona, Israel
| | - Abraham Nyska
- Toxicologic Pathology, Tel Aviv and Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
3
|
Shalaby R, Negm M, El-Sawaf M, Elsaied A, Shehata S, Hamed A, Shehata S, Radwan AB. Needlescopic Disconnection and Peritoneal Closure for Pediatric Inguinal Hernia Repair: A Novel Technique. Surg Laparosc Endosc Percutan Tech 2021; 32:272-278. [PMID: 34608108 DOI: 10.1097/sle.0000000000001001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 07/01/2021] [Indexed: 11/25/2022]
Abstract
BACKGROUND There are many laparoscopic techniques for pediatric congenital inguinal hernia repair. Needlescopic surgery was introduced recently in pediatric patients aiming at getting excellent cosmetic outcomes. PURPOSE The aim of this study was to describe a novel technique for needlescopic inguinal hernia repair in children. PATIENTS AND METHODS Needlescopic division of the hernial sac was carried out on 369 children in 6 pediatric tertiary centers during the period from August 2016 to May 2019. All hernias were repaired by a novel needlescopic procedure that replicates all the steps of the open herniotomy. RESULTS A total of 369 patients with 410 hernias were included in this study. They were 232 (62.9%) males and 137 (37.1%) females, with a mean age of 3.58±1.26 (range=2 to 8 y) and mean internal inguinal ring diameter was 13.65±3.85 mm (range=8 to 20 mm). The mean operative time was 23.36±4.67 minutes for bilateral and 14.28±2.98 minutes for unilateral cases. All cases were completed without conversion to conventional laparoscopy. All cases were followed up for a mean of 19.6±3.2 months. None of our patients developed recurrence or testicular atrophy and the scars were nearly invisible 3 months postoperatively. CONCLUSIONS Needlescopic pediatric inguinal hernia repair using disconnection of the hernia sac at internal inguinal ring with purse-string suture closure of peritoneum is feasible and safe with no recurrence and with outstanding cosmetic results.
Collapse
Affiliation(s)
- Rafik Shalaby
- Pediatric Surgery Department, Al-Azhar University Hospitals
| | - Mohamed Negm
- Pediatric Surgery Unit, South Valley University, Faculty of Medicine, Qena
| | | | - Adham Elsaied
- Pediatric Surgery Department, Mansoura University Children Hospital, Mansoura
| | - Sherif Shehata
- Pediatric Surgery Unit, Tanta University Hospitals, Tanta
| | - Ashraf Hamed
- Pediatric Surgery Department, Al-Azhar University Hospitals
| | - Sameh Shehata
- Pediatric Surgery Unit, Alexandria University hospital, Alexandria, Egypt
| | - Ahmed B Radwan
- Pediatric Surgery Department, Ain Shams University Hospitals, Cairo
| |
Collapse
|
4
|
Luo Z, Cao Z, Wang K, Li S, Cao G, Chi S, Zhang X, Li K, Zhou Y, Guo J, Tian M, Tang S. Re-evaluation of jumping purse-string suturing in pediatric laparoscopic hernia repair. Surg Endosc 2021; 36:3277-3284. [PMID: 34327548 DOI: 10.1007/s00464-021-08640-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 07/13/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND Reported recurrence rates using jumping purse-string suturing in laparoscopic hernia repair (LH) are higher than that of intact purse-string. This study aims to compare the outcomes of LH using transabdominal jumping purse-string suturing (TJS) with those using transabdominal intact purse-string suturing (TIS) and percutaneous extraperitoneal intact purse-string suturing (PEIS). METHODS A total of 3340 patients from three centers who have undergone laparoscopic hernia repair from January 2016 to June 2019 were retrospectively reviewed. Of these, 1460 patients received TJS, 724 patients received TIS, and 1006 patients received PEIS. One hundred and fifty patients were excluded due to the loss of follow-up. Demographic characteristics, intraoperative findings, and postoperative complications were analyzed. RESULTS The hernia distribution characteristics and mean length of hospital stay were similar among the three groups (p > 0.05, p > 0.05). While the overall complication rates were similar among the three groups (0.34% in TJS vs. 0.41% in TIS vs. 0.50% in PEIS, TJS & TIS p = 0.502; TJS & PEIS p = 0.813), the incidence of intraoperative hematoma in TIS group and postoperative subcutaneous knot in PEIS group was significantly higher ((0.83% in TIS and 0.34% in TJS vs. 0.2% in PEIS, TJS & TIS p = 0.018; TJS & PEIS p = 0.163), (0% in TIS and 0% in TJS vs. 0.2% in PEIS, TJS & TIS p = 0.415; TJS & PEIS p = 0.025)). There were no differences in the recurrent rate in both unilateral and bilateral cases. CONCLUSIONS Transabdominal jumping purse-string suturing is not associated with a higher recurrence rate and is the recommended surgical approach.
Collapse
Affiliation(s)
- Zhibin Luo
- Department of Pediatric Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Zhiqing Cao
- Department of Pediatric Surgery, Jiangmen Maternity and Child Health Care Hospital, Jiangmen, Guangdong Province, China
| | - Kangtai Wang
- Department of Pediatric Surgery, Hubei Enshi Autonomous Prefecture Central Hospital, Enshi City, Hubei Province, China
| | - Shuai Li
- Department of Pediatric Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Guoqing Cao
- Department of Pediatric Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Shuiqing Chi
- Department of Pediatric Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xi Zhang
- Department of Pediatric Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Kang Li
- Department of Pediatric Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Yun Zhou
- Department of Pediatric Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Jialing Guo
- Department of Pediatric Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Min Tian
- Department of Hernia and Abdominal Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
| | - Shaotao Tang
- Department of Pediatric Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
| |
Collapse
|
5
|
An Alternative Technique for Transumbilical Single-Port Laparoscopic Percutaneous Precise Closure of the Inguinal Hernia Sac in Children: A 3-Year Single-Centre Study. Gastroenterol Res Pract 2021; 2021:6679519. [PMID: 34257645 PMCID: PMC8253622 DOI: 10.1155/2021/6679519] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 06/21/2021] [Indexed: 11/18/2022] Open
Abstract
Objective To evaluate the safety and reliability of a novel technique of single-port laparoscopic-assisted percutaneous precise closure of the inguinal hernia sac in children. Methods From September 2016 through September 2019, children with inguinal hernia(s) treated with single-port laparoscopic-assisted percutaneous extraperitoneal closure using a guide wire were enrolled in this study. Operative time, surgical complications, recurrence rate, and cosmetic results were collected. Results A total of 917 cases with inguinal hernia(s) were collected. Among them, there were 886 (96.61%) boys and 31 girls. Their mean age was 5.2 ± 3.7 years. There were 693 (75.57%) cases with unilateral hernia. There were 224 cases with bilateral hernias or patent processus vaginalis, including 135 (14.72%) cases with an open contralateral ring which was confirmed intraoperatively. Twenty-three (2.51%) needed another port to complete the hernia sac separation. The operation time was 24.7 ± 5.2 min and 14.6 ± 3.8 min in bilateral and unilateral ones. Three cases complained of numbness in the thigh region or groin pain which subsided without medication in the 2nd postoperative month. There was no recurrence, and the incision scars were nearly invisible. Conclusion Single-port laparoscopic-assisted percutaneous extraperitoneal closure using a guide wire is a safe, less cost, and reliable technique in the treatment of inguinal hernia in children.
Collapse
|