1
|
Papp LA, Imre S, Bálint I, Lungu AI, Mărcutiu PE, Papp J, Ion V. Is it Time to Migrate to Liquid Chromatography Automated Platforms in the Clinical Laboratory? A Brief Point of View. J Chromatogr Sci 2024; 62:191-200. [PMID: 36715315 DOI: 10.1093/chromsci/bmad002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 11/28/2022] [Indexed: 01/31/2023]
Abstract
Liquid chromatography coupled to mass spectrometry already started to surpass the major drawbacks in terms of sensitivity, specificity and cross-reactivity that some analytical methods used in the clinical laboratory exhibit. This hyphenated technique is already preferred for specific applications while finding its own place in the clinical laboratory setting. However, large-scale usage, high-throughput analysis and lack of automation emerge as shortcomings that liquid chromatography coupled to mass spectrometry still has to overrun in order to be used on a larger scale in the clinical laboratory. The aim of this review article is to point out the present-day position of the liquid chromatography coupled to mass spectrometry technique while trying to understand how this analytical method relates to the basic working framework of the clinical laboratory. This paper offers insights about the main regulation and traceability criteria that this coupling method has to align and comply to, automation and standardization issues and finally the critical steps in sample preparation workflows all related to the high-throughput analysis framework. Further steps are to be made toward automation, speed and easy-to-use concept; however, the current technological and quality premises are favorable for chromatographic coupled to mass spectral methods.
Collapse
Affiliation(s)
- Lajos-Attila Papp
- Faculty of Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology from Targu Mures, Gheorghe Marinescu street 38, 540142 Targu Mures, Romania
- Public Health Department Mures, Gheorghe Marinescu street 40, 540136 Targu Mures, Romania
| | - Silvia Imre
- Faculty of Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology from Targu Mures, Gheorghe Marinescu street 38, 540142 Targu Mures, Romania
- Center for Advanced Medical and Pharmaceutical Research, George Emil Palade University of Medicine, Pharmacy, Science, and Technology from Targu Mures, Gheorghe Marinescu street 38, 540142 Targu Mures, Romania
| | - István Bálint
- Faculty of Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology from Targu Mures, Gheorghe Marinescu street 38, 540142 Targu Mures, Romania
- Public Health Department Mures, Gheorghe Marinescu street 40, 540136 Targu Mures, Romania
| | - Andreea-Ioana Lungu
- Faculty of Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology from Targu Mures, Gheorghe Marinescu street 38, 540142 Targu Mures, Romania
- Public Health Department Mures, Gheorghe Marinescu street 40, 540136 Targu Mures, Romania
| | - Petra-Edina Mărcutiu
- Faculty of Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology from Targu Mures, Gheorghe Marinescu street 38, 540142 Targu Mures, Romania
- Public Health Department Mures, Gheorghe Marinescu street 40, 540136 Targu Mures, Romania
| | - Júlia Papp
- Faculty of Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology from Targu Mures, Gheorghe Marinescu street 38, 540142 Targu Mures, Romania
- Public Health Department Mures, Gheorghe Marinescu street 40, 540136 Targu Mures, Romania
| | - Valentin Ion
- Faculty of Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology from Targu Mures, Gheorghe Marinescu street 38, 540142 Targu Mures, Romania
- Center for Advanced Medical and Pharmaceutical Research, George Emil Palade University of Medicine, Pharmacy, Science, and Technology from Targu Mures, Gheorghe Marinescu street 38, 540142 Targu Mures, Romania
| |
Collapse
|
2
|
Applications of Volumetric Absorptive Microsampling Technique: A Systematic Critical Review. Ther Drug Monit 2023:00007691-990000000-00101. [PMID: 36917733 DOI: 10.1097/ftd.0000000000001083] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 11/19/2022] [Indexed: 03/16/2023]
Abstract
METHODS A novel microsampling device called Volumetric Absorptive microsampling (VAMS), developed in 2014, appears to have resolved the sample inhomogeneity inherent to dried blood spots, with improved precision in the volume of sample collected for measuring drug concentration. A literature search was conducted to identify several analytical and pharmacokinetic studies that have used VAMS in recent years. RESULTS The key factors for proper experimental design and optimization of the extraction of drugs and metabolites of interest from the device were summarized. This review focuses on VAMS and elaborates on bioanalytical factors, method validation steps, and scope of this technique in clinical practice. CONCLUSIONS The promising microsampling method VAMS is especially suited for conducting pharmacokinetic studies with very small volumes of blood, especially in special patient populations. Clinical validation of every VAMS assay must be conducted prior to the routine practical implementation of this method.
Collapse
|
3
|
Zwart TC, Metscher E, van der Boog PJM, Swen JJ, de Fijter JW, Guchelaar H, de Vries APJ, Moes DJAR. Volumetric microsampling for simultaneous remote immunosuppressant and kidney function monitoring in outpatient kidney transplant recipients. Br J Clin Pharmacol 2022; 88:4854-4869. [PMID: 35670960 PMCID: PMC9796409 DOI: 10.1111/bcp.15433] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 05/20/2022] [Accepted: 05/25/2022] [Indexed: 01/01/2023] Open
Abstract
AIMS Immunosuppressant and kidney function monitoring are crucial for kidney transplant recipient follow-up. Microsamples enable remote sampling and minimise patient burden as compared to conventional venous sampling at the clinic. We developed a liquid chromatography-tandem mass spectrometry assay to quantify tacrolimus, mycophenolic acid (MPA), creatinine and iohexol in dried blood spot (DBS), and volumetric absorptive microsample (VAMS) samples. METHODS The assay was successfully validated analytically for all analytes. Clinical validation was conducted by direct comparison of paired DBS, VAMS and venous reference samples from 25 kidney transplant recipients. Patients received iohexol 5-15 minutes before immunosuppressant intake and were sampled 0, 1, 2 and 3 hours thereafter, enabling tacrolimus and MPA area under the concentration-time curve (AUC) and creatinine-based and iohexol-based glomerular filtration rate (GFR) estimation. Method agreement was evaluated using Passing-Bablok regression, Bland-Altman analysis and the percentages of values within 15-30% of the reference (P15 -P30 ) with a P20 acceptance threshold of 80%. RESULTS For DBS samples, method agreement was excellent for tacrolimus trough concentrations (n = 25, P15 = 92.0%) and AUCs (n = 25; P20 = 95.8%) and adequate for creatinine-based GFR trend monitoring (n = 25; P20 = 80%). DBS-based MPA AUC assessment showed suboptimal agreement (n = 16; P20 = 68.8%), but was considered acceptable given its P30 of 100%. The assay performed inadequately for DBS-based iohexol GFR determination (n = 24; P20 = 75%). The VAMS technique generally showed inferior performance, but can be considered for certain situations. CONCLUSION The assay was successfully validated for tacrolimus, MPA and creatinine quantification in DBS samples, enabling simultaneous remote kidney function trend monitoring and immunosuppressant therapeutic drug monitoring in kidney transplant recipients.
Collapse
Affiliation(s)
- Tom C. Zwart
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| | - Erik Metscher
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| | - Paul J. M. van der Boog
- Department of Internal Medicine (Nephrology)Leiden University Medical CenterLeidenThe Netherlands
- LUMC Transplant CenterLeiden University Medical CenterLeidenThe Netherlands
| | - Jesse J. Swen
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| | - Johan W. de Fijter
- Department of Internal Medicine (Nephrology)Leiden University Medical CenterLeidenThe Netherlands
- LUMC Transplant CenterLeiden University Medical CenterLeidenThe Netherlands
| | - Henk‐Jan Guchelaar
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| | - Aiko P. J. de Vries
- Department of Internal Medicine (Nephrology)Leiden University Medical CenterLeidenThe Netherlands
- LUMC Transplant CenterLeiden University Medical CenterLeidenThe Netherlands
| | - Dirk Jan A. R. Moes
- Department of Clinical Pharmacy and ToxicologyLeiden University Medical CenterLeidenThe Netherlands
| |
Collapse
|
4
|
Moriconi D, Nannipieri M, Dadson P, Rosada J, Tentolouris N, Rebelos E. The Beneficial Effects of Bariatric-Surgery-Induced Weight Loss on Renal Function. Metabolites 2022; 12:967. [PMID: 36295869 PMCID: PMC9608617 DOI: 10.3390/metabo12100967] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Revised: 10/08/2022] [Accepted: 10/08/2022] [Indexed: 08/05/2023] Open
Abstract
Obesity represents an independent risk factor for the development of chronic kidney disease (CKD), leading to specific histopathological alterations, known as obesity-related glomerulopathy. Bariatric surgery is the most effective means of inducing and maintaining sustained weight loss. Furthermore, in the context of bariatric-surgery-induced weight loss, a reduction in the proinflammatory state and an improvement in the adipokine profile occur, which may also contribute to the improvement of renal function following bariatric surgery. However, the assessment of renal function in the context of obesity and following marked weight loss is difficult, since the formulas adopted to estimate glomerular function use biomarkers whose production is dependent on muscle mass (creatinine) or adipose tissue mass and inflammation (cystatin-c). Thus, following bariatric surgery, the extent to which reductions in plasma concentrations reflect the actual improvement in renal function is not clear. Despite this limitation, the available literature suggests that in patients with hyperfiltration at baseline, GFR is reduced following bariatric surgery, whereas GFR is increased in patients with decreased GFR at baseline. These findings are also confirmed in the few studies that have used measured rather than estimated GFR. Albuminuria is also decreased following bariatric surgery. Moreover, bariatric surgery seems superior in achieving the remission of albuminuria and early CKD than the best medical treatment. In this article, we discuss the pathophysiology of renal complications in obesity, review the mechanisms through which weight loss induces improvements in renal function, and provide an overview of the renal outcomes following bariatric surgery.
Collapse
Affiliation(s)
- Diego Moriconi
- Department of Clinical and Experimental Medicine, University of Pisa, 56126 Pisa, Italy
| | - Monica Nannipieri
- Department of Clinical and Experimental Medicine, University of Pisa, 56126 Pisa, Italy
| | - Prince Dadson
- Turku PET Centre, University of Turku, 20500 Turku, Finland
| | - Javier Rosada
- Fourth Unit of Internal Medicine, University Hospital of Pisa, 56124 Pisa, Italy
| | - Nikolaos Tentolouris
- Department of Propaedeutic and Internal Medicine, Medical School, National and Kapodistrian University of Athens, Laiko General Hospital, 11527 Athens, Greece
| | - Eleni Rebelos
- Turku PET Centre, University of Turku, 20500 Turku, Finland
- Institute of Clinical Physiology, National Research Council (CNR), 56124 Pisa, Italy
| |
Collapse
|
5
|
Delahaye L, Veenhof H, Koch BCP, Alffenaar JWC, Linden R, Stove C. Alternative Sampling Devices to Collect Dried Blood Microsamples: State-of-the-Art. Ther Drug Monit 2021; 43:310-321. [PMID: 33470777 DOI: 10.1097/ftd.0000000000000864] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Accepted: 11/20/2020] [Indexed: 12/14/2022]
Abstract
ABSTRACT Dried blood spots (DBS) have been used in newborn screening programs for several years. More recently, there has been growing interest in using DBS as a home sampling tool for the quantitative determination of analytes. However, this presents challenges, mainly because of the well-known hematocrit effect and other DBS-specific parameters, including spotted volume and punch site, which could add to the method uncertainty. Therefore, new microsampling devices that quantitatively collect capillary dried blood are continuously being developed. In this review, we provided an overview of devices that are commercially available or under development that allow the quantitative (volumetric) collection of dried blood (-based) microsamples and are meant to be used for home or remote sampling. Considering the field of therapeutic drug monitoring (TDM), we examined different aspects that are important for a device to be implemented in clinical practice, including ease of patient use, technical performance, and ease of integration in the workflow of a clinical laboratory. Costs related to microsampling devices are briefly discussed, because this additionally plays an important role in the decision-making process. Although the added value of home sampling for TDM and the willingness of patients to perform home sampling have been demonstrated in some studies, real clinical implementation is progressing at a slower pace. More extensive evaluation of these newly developed devices, not only analytically but also clinically, is needed to demonstrate their real-life applicability, which is a prerequisite for their use in the field of TDM.
Collapse
Affiliation(s)
- Lisa Delahaye
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Belgium
| | - Herman Veenhof
- University of Groningen, Department of Clinical Pharmacy and Pharmacology, University Medical Center Groningen, Groningen, The Netherlands
| | - Birgit C P Koch
- Department of Hospital Pharmacy, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Jan-Willem C Alffenaar
- Sydney Pharmacy School, Faculty of Medicine and Health, The University of Sydney, Camperdown, NSW, Australia
- Department of Pharmacy, Westmead Hospital, Westmead, NSW, Australia
- Marie Bashir Institute of Infectious Diseases and Biosecurity, The University of Sydney, Camperdown, NSW, Australia; and
| | - Rafael Linden
- Laboratory of Analytical Toxicology, Institute of Health Sciences, Universidade Feevale, Novo Hamburgo, RS, Brazil
| | - Christophe Stove
- Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, Belgium
| |
Collapse
|
6
|
Protti M, Marasca C, Cirrincione M, Cavalli A, Mandrioli R, Mercolini L. Assessment of capillary volumetric blood microsampling for the analysis of central nervous system drugs and metabolites. Analyst 2021; 145:5744-5753. [PMID: 32749392 DOI: 10.1039/d0an01039a] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Therapeutic drug monitoring (TDM) is an important tool for correlating the administered drug dose to drug and metabolite concentrations in the body and to therapeutic and adverse effects. In the case of treatment with drugs active on the central nervous system (CNS), frequent TDM becomes really useful, especially for patient compliance checking and for therapy optimisation. The selective serotonin reuptake inhibitors (SSRIs) fluoxetine and sertraline, chosen as target compounds for this study, are two antidepressants mainly used for major depression, but also for obsessive-compulsive disorder associated with neurodegenerative diseases and for eating disorders. Microsampling approaches can be used to make TDM patient-friendly, by means of minimally invasive fingerpricking instead of classic invasive venipuncture. In this study, an innovative volumetric microsampling approach based on the use of hemaPEN technology is proposed to simultaneously obtain four identical dried whole blood microsamples by means of a single capillary sampling. The developed strategy shows significant advantages in terms of blood collection and storage, fast and feasible extraction procedure and sensitive LC-MS/MS analysis, also providing satisfactory validation results (extraction yield >81%, RSD <12.0%, and <6.3% loss in analyte stability after 3 months). The proposed methodology has proven to be sound and reliable for application to the TDM of psychiatric patients treated with antidepressant drugs such as fluoxetine and sertraline. The original capillary volumetric microsampling procedure using hemaPEN has been demonstrated to be suitable for the accurate sampling of capillary whole blood, in order to be successfully exploited in self- and home-sampling procedures in future and to pave the way for precision medicine approaches for the treatment of CNS disorders.
Collapse
Affiliation(s)
- Michele Protti
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna, Via Belmeloro 6, 40126 Bologna, Italy.
| | | | | | | | | | | |
Collapse
|
7
|
Dhondt L, Croubels S, De Cock P, Dhont E, De Baere S, De Paepe P, Devreese M. Volumetric absorptive microsampling as alternative sampling technique for renal function assessment in the paediatric population using iohexol. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1171:122623. [PMID: 33735803 DOI: 10.1016/j.jchromb.2021.122623] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 02/07/2021] [Accepted: 02/20/2021] [Indexed: 10/22/2022]
Abstract
The glomerular filtration rate (GFR) is considered the best overall index for the renal function. Currently, one of the most promising exogenous markers for GFR assessment is iohexol. In this study, the suitability of volumetric absorptive microsampling (VAMS) as alternative for the conventional blood sampling and quantification of iohexol in paediatric plasma was assessed. Therefore, a new, fully validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed. Subsequently, the clinical suitability was evaluated in 20 paediatric patients by comparing plasma iohexol concentrations and associated GFR values obtained by the VAMS method with those obtained by conventional blood sampling and quantification of iohexol in plasma. The developed, simple and cost-effective LC-MS/MS-method fulfilled all pre-set validation acceptance criteria. Iohexol could be accurately quantified within a haematocrit range of 20-60% and long-term stability of iohexol in VAMS was demonstrated up to 245 days under different storage temperatures. Both iohexol plasma concentrations (r = 0.98, mean bias: -4.20%) and derived GFR values (r = 0.99; mean bias: 1.31%), obtained by a conventional plasma and the VAMS method, demonstrated good correlation and acceptable bias. The agreement between the two methods was especially good for GFR values higher than 60 mL/min/1.73 m2. Nevertheless, for GFR values <60 mL/min/1.73 m2 the accuracy compared to the plasma method was lower. However, small adjustments to the sampling protocol could probably solve this problem.
Collapse
Affiliation(s)
- Laura Dhondt
- Department of Pharmacology, Toxicology and Biochemistry, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, Merelbeke, Belgium
| | - Siska Croubels
- Department of Pharmacology, Toxicology and Biochemistry, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, Merelbeke, Belgium
| | - Pieter De Cock
- Department of Pharmacy, Ghent University Hospital, Corneel Heymanslaan 10, Ghent, Belgium; Heymans Institute of Pharmacology, Ghent University, Corneel Heymanslaan 10, Ghent, Belgium; Department of Paediatric Intensive Care, Ghent University Hospital, Corneel Heymanslaan 10, Ghent, Belgium
| | - Evelyn Dhont
- Department of Paediatric Intensive Care, Ghent University Hospital, Corneel Heymanslaan 10, Ghent, Belgium
| | - Siegrid De Baere
- Department of Pharmacology, Toxicology and Biochemistry, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, Merelbeke, Belgium
| | - Peter De Paepe
- Heymans Institute of Pharmacology, Ghent University, Corneel Heymanslaan 10, Ghent, Belgium
| | - Mathias Devreese
- Department of Pharmacology, Toxicology and Biochemistry, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, Merelbeke, Belgium.
| |
Collapse
|
8
|
El Assri S, Sam H, El Assri A, Bentata Y, Saalaoui E, Rochdi C, Sebbar EH, Choukri M. Iohexol assay for direct determination of glomerular filtration rate: optimization and development of an HPLC-UV method for measurement in serum and urine. Clin Chim Acta 2020; 508:115-121. [DOI: 10.1016/j.cca.2020.04.038] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 04/29/2020] [Accepted: 04/30/2020] [Indexed: 12/11/2022]
|
9
|
UHPLC-MS/MS method for iohexol determination in human EDTA and lithium-heparin plasma, human urine and in goat- and pig EDTA plasma. Bioanalysis 2020; 12:981-990. [PMID: 32697606 DOI: 10.4155/bio-2020-0122] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
Aim: Iohexol plasma clearance is used as an indicator of kidney function in clinical and preclinical settings. To investigate the pharmacokinetic profile of iohexol, a rapid, simple method for measurement of iohexol in different matrices and species was needed. Materials & methods: Iohexol was separated on an Accucore C18 column (Thermo Fisher Scientific, CA, USA). Detection was performed on a Thermo Scientific Quantiva tandem quadrupole mass spectrometer. The method was validated according to the requirements for bioanalytical methods issued by the US FDA and European Medicines Agency. Conclusion: We developed and validated a fast and efficient analytical method, suitable for analyzing iohexol in human EDTA plasma, human lithium-heparin plasma, human urine and goat- and pig EDTA plasma, using only one calibration line prepared in human EDTA plasma.
Collapse
|