1
|
Freitas BLS, Fava NMDN, Melo-Neto MGD, Dalkiranis GG, Tonetti AL, Byrne JA, Fernandez-Ibañez P, Sabogal-Paz LP. Efficacy of UVC-LED radiation in bacterial, viral, and protozoan inactivation: an assessment of the influence of exposure doses and water quality. WATER RESEARCH 2024; 266:122322. [PMID: 39213680 DOI: 10.1016/j.watres.2024.122322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 08/20/2024] [Accepted: 08/23/2024] [Indexed: 09/04/2024]
Abstract
Ultraviolet light-emitting diodes (UV-LEDs) have demonstrated the ability to inactivate microorganisms in water, offering an environmentally safer alternative to the conventional mercury lamp, in UV applications. While several studies have explored the microbiological effect of UVC-LEDs (200nm-280nm), limited information exists regarding their effects on waters with critical qualities. These critical qualities encompass bacteria, viruses, and protozoa - drinking water quality indicators defined by the World Health Organization for small water systems. For the first time, this work reports on the Escherichia coli, PhiX-174, MS2, and Cryptosporidium oocysts inactivation using a bench-scale UVC-LED (280 nm) water disinfection system. UV doses at a wavelength of 280 nm (UV280) of up to 143.4 mJ/cm2 were delivered under two quality-critical water conditions: filtered water (UV transmittance at 280 nm - UVT280 90.2 %) and WHO challenge water (UVT 15.7 %). Results revealed microbiological reductions dependent on exposure time and UVT. For UV280 dose of 16.1 mJ/cm2, 2.93-3.70 log E. coli reductions were observed in UVT 90.2 % and 15.7 %, 3.49-4.21 log for PhiX-174, 0.63-0.78 log for MS2, and 0.02-0.04 log for Cryptosporidium oocysts. Significantly higher UV280 doses of 143.4 mJ/cm2 led to reductions of 3.94-5.35 log for MS2 and 0.42-0.46 log for Cryptosporidium oocysts. Statistical analysis revealed that the sensitivity among the organisms to UV280 exposure was E. coli = PhiX-174 > MS2 >> Cryptosporidium oocysts. Although experiments with WHO challenge water posed greater challenges for achieving 1 log reduction compared to filtered water, this difference only proved statistically significant for PhiX-174 and MS2 reductions. Overall, UVC-LED technology demonstrated notable efficacy in microbiological inactivation, achieving significant reductions based on WHO scheme of evaluation for POU technologies in both bacteria and viruses even in critical-quality waters. The findings emphasize the potential for extending the application of UVC-LED as a viable solution for household water treatment.
Collapse
Affiliation(s)
- Bárbara Luíza Souza Freitas
- Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil
| | - Natália Melo de Nasser Fava
- Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil
| | - Murilo Guilherme de Melo-Neto
- Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil
| | - Gustavo Gonçalves Dalkiranis
- São Carlos Institute of Physics, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil
| | - Adriano Luiz Tonetti
- School of Civil Engineering, Architecture and Urbanism - FECFAU, UNICAMP (State University of Campinas), Avenida Albert Einstein, 951, Cidade Universitária "Zeferino Vaz", Campinas, SP, 13083-852, Brazil
| | - John Anthony Byrne
- Nanotechnology and Integrated Bioengineering Centre, School of Engineering, Ulster University, Jordanstown, BT37 0QB, Northern Ireland, United Kingdom
| | - Pilar Fernandez-Ibañez
- Nanotechnology and Integrated Bioengineering Centre, School of Engineering, Ulster University, Jordanstown, BT37 0QB, Northern Ireland, United Kingdom
| | - Lyda Patricia Sabogal-Paz
- Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil.
| |
Collapse
|
2
|
Sousa M, Oliveira IM, Correia L, Gomes IB, Sousa CA, Braga DFO, Simões M. Far-UV-C irradiation promotes synergistic bactericidal action against adhered cells of Escherichia coli and Staphylococcus epidermidis. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 917:170352. [PMID: 38286293 DOI: 10.1016/j.scitotenv.2024.170352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 01/17/2024] [Accepted: 01/20/2024] [Indexed: 01/31/2024]
Abstract
The contamination of indoor areas is a global health problem that can cause the dispersion of infectious diseases. In that sense, it is urgent to find new strategies applying a lower concentration of the traditional chemicals used for cleaning and disinfection. Ultraviolet radiation (UV), in particular far-UV-C (200-225 nm), has emerged as a successful, powerful, easy-to-apply, and inexpensive approach for bacterial eradication that still requires scientific assessment. This study investigated new strategies for disinfection based on far-UV-C (222 nm) combined with chlorine and mechanical cleaning, providing an innovative solution using low doses. The bactericidal activity of far-UV-C (222 nm) was tested at an intensity of irradiation from 78.4 μW/cm2 to 597.7 μW/cm2 (for 1 min) against Escherichia coli and Staphylococcus epidermidis adhered on polystyrene microtiter plates. It was further tested in combination with mechanical cleaning (ultrasounds for 1 min) and free chlorine (0.1, 0.5, and 1 mg/L for 5 min). The triple combination consisting of mechanical cleaning + free chlorine (0.5 mg/L) + far-UV-C (54 mJ/cm2) was tested against cells adhered to materials found in hospital settings and other public spaces: polyvinyl chloride (PVC), stainless steel (SS), and polyetheretherketone (PEEK). Disinfection with far-UV-C (54 mJ/cm2) and free chlorine at 0.5 mg/L for 5 min allowed a total reduction of culturable E. coli cells and a logarithmic reduction of 2.98 ± 0.03 for S. epidermidis. The triple combination of far-UV-C, free chlorine, and mechanical cleaning resulted in a total reduction of culturable cells for both adhered bacteria. Bacterial adhesion to PVC, SS, and PEEK occurred at distinct extents and influenced the bactericidal activity of the triple combination, with logarithmic reductions of up to three. The overall results highlight that, based on culturability assessment, far-UV-C (54 mJ/cm2) with chlorine (0.5 mg/L; 5 min) and mechanical cleaning (1 min) as an efficient disinfection strategy using mild conditions. The combination of culturability and viability assessment of disinfection is recommended to detect regrowth events and increase the effectiveness in microbial growth control.
Collapse
Affiliation(s)
- M Sousa
- LEPABE-Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, Department of Chemical Engineering, University of Porto, 4200-465 Porto, Portugal; ALiCE-Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
| | - I M Oliveira
- LEPABE-Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, Department of Chemical Engineering, University of Porto, 4200-465 Porto, Portugal; ALiCE-Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
| | - L Correia
- SpinnerDynamics, Lda., Rua da Junta de Freguesia 194, 4540-322 Escariz, Arouca, Portugal
| | - I B Gomes
- LEPABE-Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, Department of Chemical Engineering, University of Porto, 4200-465 Porto, Portugal; ALiCE-Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
| | - C A Sousa
- LEPABE-Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, Department of Chemical Engineering, University of Porto, 4200-465 Porto, Portugal; ALiCE-Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
| | - D F O Braga
- SpinnerDynamics, Lda., Rua da Junta de Freguesia 194, 4540-322 Escariz, Arouca, Portugal
| | - M Simões
- LEPABE-Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, Department of Chemical Engineering, University of Porto, 4200-465 Porto, Portugal; ALiCE-Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal.
| |
Collapse
|
3
|
Salazar F, Pizarro-Oteíza S, Molinett S, Labbé M. Effect of Optimized UV-LED Technology on Modeling, Inactivation Kinetics and Microbiological Safety in Tomato Juice. Foods 2024; 13:430. [PMID: 38338565 PMCID: PMC10855617 DOI: 10.3390/foods13030430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 12/26/2023] [Accepted: 01/20/2024] [Indexed: 02/12/2024] Open
Abstract
This research analyzed, optimized and modeled the inactivation kinetics of pathogenic bacteria (PB1: Escherichia coli O157:H7 and PB2: Listeria monocytogenes) and determined the microbiological safety of tomato juice processed by UV-LED irradiation and heat treatment. UV-LED processing conditions were optimized using response surface methodology (RSM) and were 90% power intensity, 21 min and 273-275 nm (251 mJ/cm2) with R2 > 0.96. Using the optimal conditions, levels of PB1 and PB2 resulted a log reduction of 2.89 and 2.74 CFU/mL, respectively. The Weibull model was efficient for estimating the log inactivation of PB1 and PB2 (CFU/mL). The kinetic parameter δ showed that 465.2 mJ/cm2 is needed to achieve a 90% log (CFU/mL) reduction in PB1 and 511.3 mJ/cm2 for PB2. With respect to the scale parameter p > 1, there is a descending concave curve. UV-LED-treated tomato juice had an 11.4% lower Listeria monocytogenes count than heat-treated juice on day 28 (4.0 ± 0.82 °C). Therefore, UV-LED technology could be used to inactivate Escherichia coli O157:H7 and Listeria monocytogenes, preserving tomato juice for microbiological safety, but studies are required to further improve the inactivation of these pathogens and analyze other fruit and vegetable juices.
Collapse
Affiliation(s)
- Fernando Salazar
- Laboratorio de Fermentaciones Industriales, Escuela de Alimentos, Facultad de Ciencias Agronómicas y de los Alimentos, Pontificia Universidad Católica de Valparaíso, Av. Waddington 716, Valparaíso 2340000, Chile
| | - Sebastián Pizarro-Oteíza
- Laboratorio de Fermentaciones Industriales, Escuela de Alimentos, Facultad de Ciencias Agronómicas y de los Alimentos, Pontificia Universidad Católica de Valparaíso, Av. Waddington 716, Valparaíso 2340000, Chile
| | - Sebastián Molinett
- Laboratorio de Bionanotecnología, Instituto de Investigaciones Agropecuarias, INIA CRI La Cruz, Chorrillos 86, La Cruz 2280454, Chile
| | - Mariela Labbé
- Laboratorio de Fermentaciones Industriales, Escuela de Alimentos, Facultad de Ciencias Agronómicas y de los Alimentos, Pontificia Universidad Católica de Valparaíso, Av. Waddington 716, Valparaíso 2340000, Chile
| |
Collapse
|
4
|
Nicolau T, Gomes Filho N, Padrão J, Zille A. A Comprehensive Analysis of the UVC LEDs' Applications and Decontamination Capability. MATERIALS (BASEL, SWITZERLAND) 2022; 15:2854. [PMID: 35454546 PMCID: PMC9028096 DOI: 10.3390/ma15082854] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/08/2022] [Accepted: 04/11/2022] [Indexed: 01/27/2023]
Abstract
The application of light-emitting diodes (LEDs) has been gaining popularity over the last decades. LEDs have advantages compared to traditional light sources in terms of lifecycle, robustness, compactness, flexibility, and the absence of non-hazardous material. Combining these advantages with the possibility of emitting Ultraviolet C (UVC) makes LEDs serious candidates for light sources in decontamination systems. Nevertheless, it is unclear if they present better decontamination effectiveness than traditional mercury vapor lamps. Hence, this research uses a systematic literature review (SLR) to enlighten three aspects: (1) UVC LEDs' application according to the field, (2) UVC LEDs' application in terms of different biological indicators, and (3) the decontamination effectiveness of UVC LEDs in comparison to conventional lamps. UVC LEDs have spread across multiple areas, ranging from health applications to wastewater or food decontamination. The UVC LEDs' decontamination effectiveness is as good as mercury vapor lamps. In some cases, LEDs even provide better results than conventional mercury vapor lamps. However, the increase in the targets' complexity (e.g., multilayers or thicker individual layers) may reduce the UVC decontamination efficacy. Therefore, UVC LEDs still require considerable optimization. These findings are stimulating for developing industrial or final users' applications.
Collapse
Affiliation(s)
- Talita Nicolau
- 2C2T-Centre for Textile Science and Technology, University of Minho, 4800-058 Guimaraes, Portugal
| | - Núbio Gomes Filho
- School of Economics and Management, University of Minho, 4710-057 Braga, Portugal
| | - Jorge Padrão
- 2C2T-Centre for Textile Science and Technology, University of Minho, 4800-058 Guimaraes, Portugal
| | - Andrea Zille
- 2C2T-Centre for Textile Science and Technology, University of Minho, 4800-058 Guimaraes, Portugal
| |
Collapse
|