Zieliński R, Lipa S, Piechaczek M, Sowiński J, Kołkowska A, Simka W. Finite Element Analysis and Fatigue Test of INTEGRA Dental Implant System. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1213. [PMID: 38473684 DOI: 10.3390/ma17051213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 02/25/2024] [Accepted: 02/29/2024] [Indexed: 03/14/2024]
Abstract
The study involved numerical FEA (finite element analysis) of dental implants. Based on this, fatigue tests were conducted according to the PN-EN 14801 standard required for the certification of dental products. Thanks to the research methodology developed by the authors, it was possible to conduct a thorough analysis of the impact of external and internal factors such as material, geometry, loading, and assembly of the dental system on the achieved value of fatigue strength limit in the examined object. For this purpose, FEM studies were based on identifying potential sites of fatigue crack initiation in reference to the results of the test conducted on a real model. The actions described in the study helped in the final evaluation of the dental system design process named by the manufacturer as INTEGRA OPTIMA 3.35. The objective of the research was to identify potential sites for fatigue crack initiation in a selected dental system built on the INTEGRA OPTIMA 3.35 set. The material used in the research was titanium grade 4. A map of reduced von Mises stresses was used to search for potential fatigue crack areas. The research [loading] was conducted on two mutually perpendicular planes positioned in such a way that the edge intersecting the planes coincided with the axis of the system. The research indicated that the connecting screw showed the least sensitivity (stress change) to the change in the loading plane, while the value of preload has a significant impact on the achieved fatigue strength of the system. In contrast, the endosteal implant (root) and the prosthetic connector showed the greatest sensitivity to the change in the loading plane. The method of mounting [securing] the endosteal implant using a holder, despite meeting the standards, may contribute to generating excessive stress concentration in the threaded part. Observation of the prosthetic connector in the Optima 3.35 system, cyclically loaded with a force of F ≈ 300 N in the area of the upper hexagonal peg, revealed a fatigue fracture. The observed change in stress peak in the dental connector for two different force application surfaces shows that the positioning of the dental system (setting of the socket in relation to the force action plane) is significantly decisive in estimating the limited fatigue strength.
Collapse
Affiliation(s)
- Rafał Zieliński
- Stomatologia na Ksiezym Mlynie, 16 D Tymienieckiego, 90-365 Lodz, Poland
| | - Sebastian Lipa
- Institute of Materials Science and Engineering, Lodz University of Technology, 90-924 Lodz, Poland
| | - Martyna Piechaczek
- Stomatologia na Ksiezym Mlynie, 16 D Tymienieckiego, 90-365 Lodz, Poland
| | - Jerzy Sowiński
- Private Dental Clinic, Tetmajera 3A Rd., 05-080 Izabelin C, Poland
| | - Agata Kołkowska
- Chemistry Students Research Society, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland
- Department of Inorganic Chemistry, Faculty of Chemistry, Analytical Chemistry and Electrochemistry, Silesian University of Technology, 44-100 Gliwice, Poland
| | - Wojciech Simka
- Chemistry Students Research Society, Faculty of Chemistry, Silesian University of Technology, 44-100 Gliwice, Poland
| |
Collapse
|
2
|
Li M, Komasa S, Hontsu S, Hashimoto Y, Okazaki J. Structural Characterization and Osseointegrative Properties of Pulsed Laser-Deposited Fluorinated Hydroxyapatite Films on Nano-Zirconia for Implant Applications. Int J Mol Sci 2022; 23:ijms23052416. [PMID: 35269557 PMCID: PMC8910007 DOI: 10.3390/ijms23052416] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 02/18/2022] [Accepted: 02/18/2022] [Indexed: 02/01/2023] Open
Abstract
Standard zirconia implants used in restoration still present problems related to inertness and long-term stability. Various physicochemical approaches have been used to modify the implant surfaces to improve early and late bone-to-implant integration; however, no ideal surface modification has been reported. This study used pulsed laser deposition to deposit a fluorinated hydroxyapatite (FHA) film on a zirconia implant to create a biologically active surface. The film prepared was uniform, dense, and crack-free, and exhibited granular surface droplets; it also presented excellent mechanical strength and favorable biological behavior. The FHA-coated implant was implanted on the femur of Sprague-Dawley rats, and various tests and analyses were performed. Results show that the in vitro initial cell activity on the FHA-coated samples was enhanced. In addition, higher alkaline phosphatase activity and cell mineralization were detected in cells cultured on the FHA-coated groups. Further, the newly formed bone volume of the FHA-coated group was higher than that of the bare micro-adjusted composite nano-zirconia (NANOZR) group. Therefore, the FHA film facilitated osseointegration and may improve the long-term survival rates of dental implants, and could become part of a new treatment technology for implant surfaces, promoting further optimization of NANOZR implant materials.
Collapse
Affiliation(s)
- Min Li
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazono-cho, Hirakata 573-1121, Japan; (S.K.); (J.O.)
- Correspondence: ; Tel.: +81-080-3808-2228
| | - Satoshi Komasa
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazono-cho, Hirakata 573-1121, Japan; (S.K.); (J.O.)
| | - Shigeki Hontsu
- Department of Biomedical Engineering, Faculty of Biology-Oriented Science and Technology, Kindai University, 930 Nishimitani, Kinokawa 649-6493, Japan;
| | - Yoshiya Hashimoto
- Department of Biomaterials, Osaka Dental University, 8-1 Kuzuhahanazono-cho, Hirakata 573-1121, Japan;
| | - Joji Okazaki
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazono-cho, Hirakata 573-1121, Japan; (S.K.); (J.O.)
| |
Collapse
|
3
|
Molaei M, Attarzadeh N, Fattah-Alhosseini A. Tailoring the biological response of zirconium implants using zirconia bioceramic coatings: A systematic review. J Trace Elem Med Biol 2021; 66:126756. [PMID: 33831798 DOI: 10.1016/j.jtemb.2021.126756] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 03/18/2021] [Accepted: 03/29/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND The poor biological performance of zirconium implants in the human body resulting from their bio-inertness and vulnerability to corrosion and bacterial activity reflects the need for further studies on substitution or performing the surface modification. The suggestion of employing zirconia (ZrO2) bioceramic coatings for surface modification seems beneficial. OBJECTIVES This systematic review aims to identify and summarize existing documents reporting the biological responses for ZrO2 coatings produced by the PEO process on zirconium implants. METHODS PubMed, Scopus, and Web of Science international databases were searched for the original and English-language studies published between 2000 and 2021. All publications reported at least one study about in-vitro (cellular and immersion studies), in-vivo (animal studies), and antibacterial topics for ZrO2-PEO coated zirconium implants. RESULTS Throughout the initial search, 496 publications were found, and 296 papers remained following the elimination of duplicates. Finally, after multiple screening and eligibility assessments, 25 publications were qualified and included in the review. Among them, 25 in-vitro (cellular and immersion in SBF and Hanks' solutions studies), one in-vivo (animal studies), and eight antibacterial studies were found. CONCLUSION The ZrO2 coated samples demonstrate no cytotoxicity, high cell viability rate, and excellent biocompatibility. However, changing the solution composition and electrical parameters during the PEO procedures result in significant changes to in-vitro responses. As an instance, the ZrO2 coating surface demonstrates greater biocompatibility after irradiated by UV, which makes the surface more suitable for cell growth. Due to weak apatite-forming ability, the zirconium sample shows low bioactivity in SBF. However, most cases (13 out of 16) show that the specific morphology and chemical composition of the ZrO2 coating promote apatite-forming ability with good bioactivity in SBF. Nevertheless, few papers (three out of 16) showed that the ZrO2 coatings immersed in SBF had no apatite precipitates and so no bioactivity. These cases limit the bioactivity enhancement to treatment by UV-light irradiation, hydrothermal and chemical treatment, thermal evaporation, and cathodic polarization post-treatment on ZrO2 coatings. Both zirconium and ZrO2 coated samples do not show apatite-forming ability in Hanks' solution. The ZrO2 coated implant with the bone together indicates a greater shear strength and rapid new bone formation ability during 12 weeks because of containing Ca-P compounds and porous structure. The UV post-treated ZrO2 coating induces faster new bone formation and firmer connection of bond with bone than those of untreated ZrO2 coatings. A stronger antibacterial activity of ZrO2 coatings is confirmed in half of the selected papers (four out of eight studies) compared to the bare zirconium samples. The antibacterial protection of ZrO2 coatings can be influenced by the PEO procedure variables, i.e., solution composition, electrical parameters, and treatment time. In three cases, the antibacterial activity of ZrO2 coatings is enhanced by deposition of Zn, Ag, or Cu antibacterial layers through thermal evaporation post-treatment.
Collapse
Affiliation(s)
- Maryam Molaei
- Department of Materials Engineering, Bu-Ali Sina University, Hamedan, 65178-38695, Iran
| | - Navid Attarzadeh
- Environmental Science and Engineering Program, University of Texas at El Paso, El Paso, TX, 79968, USA
| | | |
Collapse
|
4
|
Burkhardt F, Harlass M, Adolfsson E, Vach K, Spies BC, Kohal RJ. A Novel Zirconia-Based Composite Presents an Aging Resistant Material for Narrow-Diameter Ceramic Implants. MATERIALS 2021; 14:ma14092151. [PMID: 33922688 PMCID: PMC8122934 DOI: 10.3390/ma14092151] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 04/19/2021] [Accepted: 04/21/2021] [Indexed: 01/23/2023]
Abstract
A novel ceria-stabilized zirconia-alumina-aluminate composite (Ce-TZP-comp) that is not prone to aging presents a potential alternative to yttrium-stabilized zirconia for ceramic oral implants. The objective of this study was to evaluate the long-term stability of a one-piece narrow-diameter implant made of Ce-TZP-comp. Implant prototypes with a narrow (3.4 mm) and regular (4.0 mm) diameter were embedded according to ISO 14801, and subgroups (n = 8) were subsequently exposed to dynamic loading (107 cycles, 98N) and/or hydrothermal treatment (aging, 85 °C). Loading/aging was only applied as a combined protocol for the 4.0 mm diameter implants. One subgroup of each diameter remained untreated. One sample was cross-sectioned from each subgroup and evaluated with a scanning electron microscope for phase-transformation of the lattice. Finally, the remaining samples were loaded to fracture. A multivariate linear regression model was applied for statistical analyses (significance at p < 0.05). All samples withstood the different loading/aging protocols and no transformation propagation was observed. The narrow diameter implants showed the lowest fracture load after combined loading/aging (628 ± 56 N; p < 0.01), whereas all other subgroups exhibited no significantly reduced fracture resistance (between 762 ± 62 and 806 ± 73 N; p > 0.05). Therefore, fracture load values of Ce-TZP-comp implants suggest a reliable intraoral clinical application in the anterior jaw regions.
Collapse
Affiliation(s)
- Felix Burkhardt
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
| | - Markus Harlass
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
| | | | - Kirstin Vach
- Medical Center—University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
| | - Ralf-Joachim Kohal
- Medical Center—University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; (F.B.); (M.H.); (B.C.S.)
- Correspondence:
| |
Collapse
|
5
|
Optimized Planning and Evaluation of Dental Implant Fatigue Testing: A Specific Software Application. BIOLOGY 2020; 9:biology9110372. [PMID: 33142807 PMCID: PMC7693306 DOI: 10.3390/biology9110372] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 10/29/2020] [Accepted: 10/30/2020] [Indexed: 11/17/2022]
Abstract
Mechanical complications in implant-supported fixed dental prostheses are often related to implant and prosthetic design. Although the current ISO 14801 provides a framework for the evaluation of dental implant mechanical reliability, strict adherence to it may be difficult to achieve due to the large number of test specimens which it requires as well as the fact that it does not offer any probabilistic reference for determining the endurance limit. In order to address these issues, a new software program called ProFatigue is presented as a potentially powerful tool to optimize fatigue testing of implant-supported prostheses. The present work provides a brief description of some concepts such as load, fatigue and stress-number of cycles to failure curves (S-N curves), before subsequently describing the current regulatory situation. After analyzing the two most recent versions of the ISO recommendation (from 2008 and 2016), some limitations inherent to the experimental methods which they propose are highlighted. Finally, the main advantages and instructions for the correct implementation of the ProFatigue free software are given. This software will contribute to improving the performance of fatigue testing in a more accurate and optimized way, helping researchers to gain a better understanding of the behavior of dental implants in this type of mechanical test.
Collapse
|
6
|
Bethke A, Pieralli S, Kohal RJ, Burkhardt F, von Stein-Lausnitz M, Vach K, Spies BC. Fracture Resistance of Zirconia Oral Implants In Vitro: A Systematic Review and Meta-Analysis. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E562. [PMID: 31991565 PMCID: PMC7040771 DOI: 10.3390/ma13030562] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 01/15/2020] [Accepted: 01/21/2020] [Indexed: 12/27/2022]
Abstract
Various protocols are available to preclinically assess the fracture resistance of zirconia oral implants. The objective of the present review was to determine the impact of different treatments (dynamic loading, hydrothermal aging) and implant features (e.g., material, design or manufacturing) on the fracture resistance of zirconia implants. An electronic screening of two databases (MEDLINE/Pubmed, Embase) was performed. Investigations including > 5 screw-shaped implants providing information to calculate the bending moment at the time point of static loading to fracture were considered. Data was extracted and meta-analyses were conducted using multilevel mixed-effects generalized linear models (GLMs). The Šidák method was used to correct for multiple testing. The initial search resulted in 1864 articles, and finally 19 investigations loading 731 zirconia implants to fracture were analyzed. In general, fracture resistance was affected by the implant design (1-piece > 2-piece, p = 0.004), material (alumina-toughened zirconia/ATZ > yttria-stabilized tetragonal zirconia polycrystal/Y-TZP, p = 0.002) and abutment preparation (untouched > modified/grinded, p < 0.001). In case of 2-piece implants, the amount of dynamic loading cycles prior to static loading (p < 0.001) or anatomical crown supply (p < 0.001) negatively affected the outcome. No impact was found for hydrothermal aging. Heterogeneous findings of the present review highlight the importance of thoroughly and individually evaluating the fracture resistance of every zirconia implant system prior to market release.
Collapse
Affiliation(s)
- Annalena Bethke
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Stefano Pieralli
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Felix Burkhardt
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| | - Manja von Stein-Lausnitz
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
| | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Faculty of Medicine, Medical Center—University of Freiburg, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany;
| | - Benedikt Christopher Spies
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, 14197 Berlin, Germany; (A.B.); (S.P.); (F.B.); (M.v.S.-L.)
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center—University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany;
| |
Collapse
|
7
|
Spies BC, Fross A, Adolfsson E, Bagegni A, Doerken S, Kohal RJ. Stability and aging resistance of a zirconia oral implant using a carbon fiber-reinforced screw for implant-abutment connection. Dent Mater 2018; 34:1585-1595. [PMID: 30180975 DOI: 10.1016/j.dental.2018.08.290] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 07/16/2018] [Accepted: 08/18/2018] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To investigate the long-term stability of a metal-free zirconia two-piece implant assembled with a carbon fiber-reinforced (CRF) screw by means of transformation propagation, potential changes in surface roughness, the gap size of the implant-abutment connection, and fracture load values. METHODS In a combined procedure, two-piece implants made from alumina-toughened zirconia were dynamically loaded (107 cycles) and hydrothermally aged (85°, 60days). Implants made from titanium (Ti) and a titanium-zirconium (TiZr) alloy with a titanium abutment screw served as control. Transformation propagation (ATZ) and gap size of the IAC were monitored at cross-sections by scanning electron microscopy (SEM). Furthermore, changes in surface roughness of ATZ implants were measured. Finally, implants were statically loaded to fracture. Linear regression models and pairwise comparisons were used for statistical analyses. RESULTS Independent of the implant bulk material, dynamic loading/hydrothermal aging did not decrease fracture resistance (p=0.704). All test and control implants fractured at mean loads >1100N. Gap size of the IAC remained stable (<5μm) or decreased. None of the CFR screws fractured during static or dynamic loading. Monoclinic layer thickness of ATZ implants increased by 2-3μm at surfaces exposed to water, including internal surfaces of the IAC. No changes in surface roughness were observed. SIGNIFICANCE Combined hydrothermal aging and dynamic loading did not affect the above-mentioned parameters of the evaluated two-piece ATZ implant. Mean fracture loads >1100N suggest a reliable clinical application.
Collapse
Affiliation(s)
- Benedikt C Spies
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Str. 4-6, Berlin, Germany.
| | - Alexander Fross
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | | | - Aimen Bagegni
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Sam Doerken
- Medical Center - University of Freiburg, Institute of Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Stefan-Meier-Str. 26, 79104 Freiburg, Germany
| | - Ralf-Joachim Kohal
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| |
Collapse
|