1
|
Huang X, Schwenke DW, Freedman RS, Lee TJ. Ames-2021 CO 2 Dipole Moment Surface and IR Line Lists: Toward 0.1% Uncertainty for CO 2 IR Intensities. J Phys Chem A 2022; 126:5940-5964. [PMID: 36007245 DOI: 10.1021/acs.jpca.2c01291] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A highly accurate CO2 ab initio dipole moment surface (DMS), Ames-2021, is reported along with 12C16O2 infrared (IR) intensity comparisons approaching a 1-4‰ level of agreement and uncertainty. The Ames-2021 DMS was accurately fitted from CCSD(T) finite-field dipoles computed with the aug-cc-pVXZ (X = T, Q, 5) basis for C atom and the d-aug-cc-pVXZ (X = T, Q, 5) basis for O atoms, and extrapolated to the one particle basis set limit. Fitting σrms is 3.8 × 10-7 au for 4443 geometries below 15 000 cm-1. The corresponding IR intensity, SAmes-2021, are computed using the Ames-2 potential energy surface (PES), which is the best PES available for CO2. Compared to high accuracy IR studies for 2001i-00001 and 3001i-00001 bands, SAmes-2021 matches NIST experiment-based intensities [SNIST-HIT16 or SHIT20] to -1.0 ± 1.3‰, or matches DLR experiment-based intensities [SDLR-HIT16/UCL/Ames] to 1.9 ± 3.7‰. This indicates the systematic deviations and uncertainties have been significantly reduced in SAmes-2021. The SUCL2015 (or SHITRAN2016) have larger deviations (vs SDLR) and uncertainties (vs SDLR, SNIST) which are attributed to the less accurate Ames-1 PES adopted in UCL-296 line list calculation. The SAmes-2021 intensity of 12C16O2 and 13C16O2 is utilized to derive new absolute 13C/12C ratios for Vienna PeeDee Belemnite (VPDB) with uncertainty reduced by 1/3 or 2/3. Further evaluation of SAmes-2021 intensities are carried out on those CO2 bands discussed in the HITRAN2020 update paper. Consistent improvements and better accuracies are found in band-by-band analysis, except for those bands strongly affected by Coriolis couplings, or very weak bands measured with relatively larger experimental uncertainties. The Ames-2021 296 K IR line lists are generated for 13 CO2 isotopologues, with 18 000 cm-1 and S296 K > 1 × 10-31 cm/molecule cutoff and then combined with CDSD line positions (except 14C16O2). The Ames-2021 DMS and 296 K IR line lists represent a major improvement over previous CO2 theoretical IR intensity studies, including Ames-2016, UCL-296, and recent UCL DMS 2021 update. A real 1 permille level of agreement and uncertainty will definitely require both more accurate PES and more accurate DMS.
Collapse
Affiliation(s)
- Xinchuan Huang
- MS 245-6, Astrophysics Branch, Space Science and Astrobiology Division, NASA Ames Research Center, Moffett Field, California 94035, United States.,SETI Institute, 339 Bernardo Avenue, Suite 200, Mountain View, California 94043, United States
| | - David W Schwenke
- MS 258-2, NAS Facility, NASA Ames Research Center, Moffett Field, California 94035, United States
| | - Richard S Freedman
- SETI Institute, 339 Bernardo Avenue, Suite 200, Mountain View, California 94043, United States.,MS 245-3, Planetary Systems Branch, Space Science and Astrobiology Division, NASA Ames Research Center, Moffett Field, California 94035, United States
| | - Timothy J Lee
- MS 245-3, Planetary Systems Branch, Space Science and Astrobiology Division, NASA Ames Research Center, Moffett Field, California 94035, United States
| |
Collapse
|
2
|
Fleisher AJ, Yi H, Srivastava A, Polyansky OL, Zobov NF, Hodges JT. Absolute 13C/ 12C Isotope Amount Ratio for Vienna Pee Dee Belemnite from Infrared Absorption Spectroscopy. NATURE PHYSICS 2021; 17:10.1038/s41567-021-01226-y. [PMID: 36873572 PMCID: PMC9982939 DOI: 10.1038/s41567-021-01226-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Measurements of isotope ratios are predominantly made with reference to standard specimens that have been characterized in the past. In the 1950s, the carbon isotope ratio was referenced to a belemnite sample collected by Heinz Lowenstam and Harold Urey1 in South Carolina's Pee Dee region. Due to the exhaustion of the sample since then, reference materials that are traceable to the original artefact are used to define the Vienna Pee Dee Belemnite (VPDB) scale for stable carbon isotope analysis2. However, these reference materials have also become exhausted or proven to exhibit unstable composition over time3, mirroring issues with the international prototype of the kilogram that led to a revised International System of Units4. A campaign to elucidate the stable carbon isotope ratio of VPDB is underway5, but independent measurement techniques are required to support it. Here we report an accurate value for the stable carbon isotope ratio inferred from infrared absorption spectroscopy, fulfilling the promise of this fundamentally accurate approach6. Our results agree with a value recently derived from mass spectrometry5, and therefore advance the prospects of SI-traceable isotope analysis. Further, our calibration-free method could improve mass balance calculations and enhance isotopic tracer studies in CO2 source apportionment.
Collapse
Affiliation(s)
- Adam J. Fleisher
- Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
- These authors contributed equally: Adam J. Fleisher, Hongming Yi
- To whom correspondence should be addressed: , phone: 301-975-4864, National Institute of Standards and Technology, 100 Bureau Drive, Mailstop 8320, Gaithersburg, MD 20899, USA
| | - Hongming Yi
- Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
- These authors contributed equally: Adam J. Fleisher, Hongming Yi
- Present affiliation: The Department of Civil and Environmental Engineering, Princeton University, Princeton, NJ, USA
| | - Abneesh Srivastava
- Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
| | - Oleg L. Polyansky
- Department of Physics and Astronomy, University College London, London, UK
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Nikolai F. Zobov
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Joseph T. Hodges
- Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
| |
Collapse
|
3
|
Wu H, Hu CL, Wang J, Sun YR, Tan Y, Liu AW, Hu SM. A well-isolated vibrational state of CO2verified by near-infrared saturated spectroscopy with kHz accuracy. Phys Chem Chem Phys 2020; 22:2841-2848. [DOI: 10.1039/c9cp05121j] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Quantitative determination of atmospheric CO2concentration by remote sensing relies on accurate line parameters.
Collapse
Affiliation(s)
- Hao Wu
- Hefei National Laboratory for Physical Sciences at Microscale
- iChem Center
- University of Science and Technology of China
- Hefei
- China
| | - Chang-Le Hu
- Hefei National Laboratory for Physical Sciences at Microscale
- iChem Center
- University of Science and Technology of China
- Hefei
- China
| | - Jin Wang
- Hefei National Laboratory for Physical Sciences at Microscale
- iChem Center
- University of Science and Technology of China
- Hefei
- China
| | - Yu R. Sun
- Hefei National Laboratory for Physical Sciences at Microscale
- iChem Center
- University of Science and Technology of China
- Hefei
- China
| | - Yan Tan
- Hefei National Laboratory for Physical Sciences at Microscale
- iChem Center
- University of Science and Technology of China
- Hefei
- China
| | - An-Wen Liu
- Hefei National Laboratory for Physical Sciences at Microscale
- iChem Center
- University of Science and Technology of China
- Hefei
- China
| | - Shui-Ming Hu
- Hefei National Laboratory for Physical Sciences at Microscale
- iChem Center
- University of Science and Technology of China
- Hefei
- China
| |
Collapse
|
4
|
Fleurbaey H, Yi H, Adkins EM, Fleisher AJ, Hodges JT. Cavity ring-down spectroscopy of CO 2 near λ = 2.06 μm: Accurate transition intensities for the Orbiting Carbon Observatory-2 (OCO-2) "strong band". JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER 2020; 252:https://doi.org/10.1016/j.jqsrt.2020.107104. [PMID: 33100382 DOI: 10.1016/j.jqsrt.2020.107104] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The λ = 2.06 μm absorption band of CO2 is widely used for the remote sensing of atmospheric carbon dioxide, making it relevant to many important top-down measurements of carbon flux. The forward models used in the retrieval algorithms employed in these measurements require increasingly accurate line intensity and line shape data from which absorption cross-sections can be computed. To overcome accuracy limitations of existing line lists, we used frequency-stabilized cavity ring-down spectroscopy to measure 39 transitions in the 12C16O2 absorption band. The line intensities were measured with an estimated relative combined standard uncertainty of u r = 0.08 %. We predicted the J-dependence of the measured intensities using two theoretical models: a one-dimensional spectroscopic model with Herman-Wallis rotation-vibration corrections, and a line-by-line ab initio dipole moment surface model [Zak et al. JQSRT 2016;177:31-42]. For the second approach, we fit only a single factor to rescale the theoretical integrated band intensity to be consistent with the measured intensities. We find that the latter approach yields an equally adequate representation of the fitted J-dependent intensity data and provides the most physically general representation of the results. Our recommended value for the integrated band intensity equal to 7.183 × 10-21 cm molecule-1 ± 6 × 10-24 cm molecule-1 is based on the rescaled ab initio model and corresponds to a fitted scale factor of 1.0069 ± 0.0002. Comparisons of literature intensity values to our results reveal systematic deviations ranging from -1.16 % to +0.33 %.
Collapse
Affiliation(s)
- Hélène Fleurbaey
- Material Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899, USA
| | - Hongming Yi
- Material Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899, USA
| | - Erin M Adkins
- Material Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899, USA
| | - Adam J Fleisher
- Material Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899, USA
| | - Joseph T Hodges
- Material Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899, USA
| |
Collapse
|
5
|
Yi H, Fleisher AJ. High-resolution cavity ring-down spectroscopy of the ν1 + ν6 combination band of methanol at 2.0 μm. J Chem Phys 2019; 151:234202. [DOI: 10.1063/1.5125146] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Affiliation(s)
- Hongming Yi
- Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA
| | - Adam J. Fleisher
- Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, USA
| |
Collapse
|
6
|
Fleisher AJ, Adkins EM, Reed ZD, Yi H, Long DA, Fleurbaey HM, Hodges JT. Twenty-Five-Fold Reduction in Measurement Uncertainty for a Molecular Line Intensity. PHYSICAL REVIEW LETTERS 2019; 123:043001. [PMID: 31491247 PMCID: PMC6767615 DOI: 10.1103/physrevlett.123.043001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 06/06/2019] [Indexed: 05/06/2023]
Abstract
To accurately attribute sources and sinks of molecules like CO_{2}, remote sensing missions require line intensities (S) with relative uncertainties u_{r}(S)<0.1%. However, discrepancies in S of ≈1% are common when comparing different experiments, thus limiting their potential impact. Here we report a cavity ring-down spectroscopy multi-instrument comparison which revealed that the hardware used to digitize analog ring-down signals caused variability in spectral integrals which yield S. Our refined approach improved measurement accuracy 25-fold, resulting in u_{r}(S)=0.06%.
Collapse
Affiliation(s)
- Adam J Fleisher
- National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, USA
| | - Erin M Adkins
- National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, USA
| | - Zachary D Reed
- National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, USA
| | - Hongming Yi
- National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, USA
| | - David A Long
- National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, USA
| | - Hélène M Fleurbaey
- National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, USA
| | - Joseph T Hodges
- National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, USA
| |
Collapse
|
7
|
Fleisher AJ, Long DA, Liu Q, Gameson L, Hodges JT. Optical Measurement of Radiocarbon below Unity Fraction Modern by Linear Absorption Spectroscopy. J Phys Chem Lett 2017; 8:4550-4556. [PMID: 28880564 PMCID: PMC5725230 DOI: 10.1021/acs.jpclett.7b02105] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
High-precision measurements of radiocarbon (14C) near or below a fraction modern 14C of 1 (F14C ≤ 1) are challenging and costly. An accurate, ultrasensitive linear absorption approach to detecting 14C would provide a simple and robust benchtop alternative to off-site accelerator mass spectrometry facilities. Here we report the quantitative measurement of 14C in gas-phase samples of CO2 with F14C < 1 using cavity ring-down spectroscopy in the linear absorption regime. Repeated analysis of CO2 derived from the combustion of either biogenic or petrogenic sources revealed a robust ability to differentiate samples with F14C < 1. With a combined uncertainty of 14C/12C = 130 fmol/mol (F14C = 0.11), initial performance of the calibration-free instrument is sufficient to investigate a variety of applications in radiocarbon measurement science including the study of biofuels and bioplastics, illicitly traded specimens, bomb dating, and atmospheric transport.
Collapse
|