1
|
Burt LA, Wyatt PM, Morrison A, Boyd SK. Bone Quality in Competitive Athletes: A Systematic Review. JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS 2023; 23:456-470. [PMID: 38037364 PMCID: PMC10696374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Accepted: 09/08/2023] [Indexed: 12/02/2023]
Abstract
The study objective was to assess bone quality measured by high resolution peripheral quantitative computed tomography (HR-pQCT) in competitive athletes. Medline, EMBASE and Sport Discus were searched through May 2022. Prior to submission, a follow-up database search was performed (January 2023). Studies of competitive athletes using HR-pQCT to assess bone quality were included. Athletes were aged between 14 and 45 years. Data extraction included study design and location (country), skeletal imaging modality and site, bone variables and any additional musculoskeletal-related outcome. Information identifying sports and athletes were also extracted. This review included 14 manuscripts and a total of 928 individuals (male: n=75; female: n=853). Athletes comprised 78% (n=722) of the included individuals and 93% of athletes were female. Assessment scores indicate the studies were good to fair quality. The athletes included in this review can be categorized into three groups: 1) healthy athletes, 2) athletes with compromised menstrual function (e.g., amenorrhoea), and 3) athletes with compromised bone health (e.g., bone stress injuries). When assessing bone quality using HR-pQCT, healthy competitive athletes had denser, stronger and larger bones with better microarchitecture, compared with controls. However, the same cannot be said for athletes with amenorrhoea or bone stress injuries.
Collapse
Affiliation(s)
- Lauren A. Burt
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, Canada
| | - Paige M. Wyatt
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, Canada
- Canadian Sports Institute, Calgary, Canada
| | - Alida Morrison
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, Canada
| | - Steven K. Boyd
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, Canada
| |
Collapse
|
2
|
Burt LA, Groves EM, Quipp K, Boyd SK. Bone density, microarchitecture and strength in elite figure skaters is discipline dependent. J Sci Med Sport 2021; 25:173-177. [PMID: 34607766 DOI: 10.1016/j.jsams.2021.09.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 08/09/2021] [Accepted: 09/02/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVES In elite figure skaters, to determine if there was a difference in volumetric bone mineral density and bone strength between 1) figure skaters and population-based normative data, 2) single or pair skaters and ice dancers, and 3) the landing and takeoff legs. DESIGN Cross-sectional. METHODS Figure skaters had their non-dominant distal radius and bilateral tibia scanned using high-resolution peripheral quantitative computed tomography. Volumetric bone mineral density was determined at the total, cortical and trabecular compartments, and finite element analysis estimated bone strength. Normative data was used to compare the total bone mineral density of figure skaters to a population-based cohort. Independent t-tests compared differences between skating discipline, and paired t-tests compared skeletal parameters for the landing and takeoff leg. RESULTS Twenty elite skaters (mean age 22 ± 6.2; female = 11, male = 9) completed scans. Compared with the general population, the mean percentile rank for skaters' total volumetric bone mineral density was below normal at the radius (27th percentile) and normal at the tibia (54th percentile). Single or pair skaters had more robust bone in the landing compared with their takeoff leg. Specifically, the landing leg had higher total bone mineral density (2.8%) and trabecular bone mineral density (6.5%), and superior bone strength (8.5%) than the takeoff leg (p < 0.05). CONCLUSIONS Volumetric bone mineral density and strength differences in figure skaters were discipline dependent. Side-to-side differences were observed in single and pair skaters where the landing leg is denser, larger and stronger than the takeoff leg.
Collapse
Affiliation(s)
- Lauren A Burt
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Canada.
| | | | | | - Steven K Boyd
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Canada.
| |
Collapse
|
3
|
Warden SJ, Wright CS, Fuchs RK. Bone Microarchitecture and Strength Adaptation to Physical Activity: A Within-Subject Controlled HRpQCT Study. Med Sci Sports Exerc 2021; 53:1179-1187. [PMID: 33394902 DOI: 10.1249/mss.0000000000002571] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
PURPOSE Physical activity benefits bone mass and cortical bone size. The current study assessed the impact of chronic (≥10 yr) physical activity on trabecular microarchitectural properties and microfinite element analyses of estimated bone strength. METHODS Female collegiate-level tennis players (n = 15; age = 20.3 ± 0.9 yr) were used as a within-subject controlled model of chronic unilateral upper-extremity physical activity. Racquet-to-nonracquet arm differences at the distal radius and radial diaphysis were assessed using high-resolution peripheral quantitative computed tomography. The distal tibia and the tibial diaphysis in both legs were also assessed, and cross-country runners (n = 15; age = 20.8 ± 1.2 yr) included as controls. RESULTS The distal radius of the racquet arm had 11.8% (95% confidence interval [CI] = 7.9% to 15.7%) greater trabecular bone volume/tissue volume, with trabeculae that were greater in number, thickness, connectivity, and proximity to each other than that in the nonracquet arm (all P < 0.01). Combined with enhanced cortical bone properties, the microarchitectural advantages at the distal radius contributed a 18.7% (95% CI = 13.0% to 24.4%) racquet-to-nonracquet arm difference in predicted load before failure. At the radial diaphysis, predicted load to failure was 9.6% (95% CI = 6.7% to 12.6%) greater in the racquet versus nonracquet arm. There were fewer and smaller side-to-side differences at the distal tibia; however, the tibial diaphysis in the leg opposite the racquet arm was larger with a thicker cortex and had 4.4% (95% CI = 1.7% to 7.1%) greater strength than the contralateral leg. CONCLUSION Chronically elevated physical activity enhances trabecular microarchitecture and microfinite element estimated strength, furthering observations from short-term longitudinal studies. The data also demonstrate that tennis players exhibit crossed symmetry wherein the leg opposite the racquet arm possesses enhanced tibial properties compared with in the contralateral leg.
Collapse
|
4
|
Whittier DE, Boyd SK, Burghardt AJ, Paccou J, Ghasem-Zadeh A, Chapurlat R, Engelke K, Bouxsein ML. Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography. Osteoporos Int 2020; 31:1607-1627. [PMID: 32458029 PMCID: PMC7429313 DOI: 10.1007/s00198-020-05438-5] [Citation(s) in RCA: 169] [Impact Index Per Article: 42.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Accepted: 04/23/2020] [Indexed: 12/29/2022]
Abstract
INTRODUCTION The application of high-resolution peripheral quantitative computed tomography (HR-pQCT) to assess bone microarchitecture has grown rapidly since its introduction in 2005. As the use of HR-pQCT for clinical research continues to grow, there is an urgent need to form a consensus on imaging and analysis methodologies so that studies can be appropriately compared. In addition, with the recent introduction of the second-generation HrpQCT, which differs from the first-generation HR-pQCT in scan region, resolution, and morphological measurement techniques, there is a need for guidelines on appropriate reporting of results and considerations as the field adopts newer systems. METHODS A joint working group between the International Osteoporosis Foundation, American Society of Bone and Mineral Research, and European Calcified Tissue Society convened in person and by teleconference over several years to produce the guidelines and recommendations presented in this document. RESULTS An overview and discussion is provided for (1) standardized protocol for imaging distal radius and tibia sites using HR-pQCT, with the importance of quality control and operator training discussed; (2) standardized terminology and recommendations on reporting results; (3) factors influencing accuracy and precision error, with considerations for longitudinal and multi-center study designs; and finally (4) comparison between scanner generations and other high-resolution CT systems. CONCLUSION This article addresses the need for standardization of HR-pQCT imaging techniques and terminology, provides guidance on interpretation and reporting of results, and discusses unresolved issues in the field.
Collapse
Affiliation(s)
- D E Whittier
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - S K Boyd
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - A J Burghardt
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - J Paccou
- Department of Rheumatology, MABlab UR 4490, CHU Lille, Univ. Lille, 59000, Lille, France
| | - A Ghasem-Zadeh
- Departments of Endocrinology and Medicine, Austin Health, The University of Melbourne, Melbourne, Australia
| | - R Chapurlat
- INSERM UMR 1033, Université de Lyon, Lyon, France
- Hôpital Edouard Herriot, Hospice Civils de Lyon, Lyon, France
| | - K Engelke
- Department of Medicine 3, FAU University Erlangen-Nürnberg and Universitätsklinikum Erlangen, Erlangen, Germany
- Bioclinica, Inc., Hamburg, Germany
| | - M L Bouxsein
- Center for Advanced Orthopedic Studies, Beth Israel Deaconess Medical Center, Boston, MA, USA.
- Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
5
|
Arias-Moreno AJ, Hosseini HS, Bevers M, Ito K, Zysset P, van Rietbergen B. Validation of distal radius failure load predictions by homogenized- and micro-finite element analyses based on second-generation high-resolution peripheral quantitative CT images. Osteoporos Int 2019; 30:1433-1443. [PMID: 30997546 PMCID: PMC6614386 DOI: 10.1007/s00198-019-04935-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Accepted: 03/05/2019] [Indexed: 12/15/2022]
Abstract
UNLABELLED This study developed a well-standardized and reproducible approach for micro-finite element (mFE) and homogenized-FE (hFE) analyses that can accurately predict the distal radius failure load using either mFE or hFE models when using the approaches and parameters developed in this study. INTRODUCTION Micro-FE analyses based on high-resolution peripheral quantitative CT (HR-pQCT) images are frequently used to predict distal radius failure load. With the introduction of a second-generation HR-pQCT device, however, the default modelling approach no longer provides accurate results. The aim of this study was to develop a well-standardized and reproducible approach for mFE and hFE analyses that can provide precise and accurate results for distal radius failure load predictions based on second-generation HR-pQCT images. METHODS Second-generation HR-pQCT was used to scan the distal 20-mm section of 22 cadaver radii. The sections were excised and mechanically tested afterwards. For these sections, mFE and hFE models were made that were used to identify required material parameters by comparing predicted and measured results. Using these parameters, the models were cropped to represent the 10-mm region recommended for clinical studies to test their performance for failure load prediction. RESULTS After identification of material parameters, the measured failure load of the 20-mm segments was in good agreement with the results of mFE models (R2 = 0.969, slope = 1.035) and hFE models (R2 = 0.966, slope = 0.890). When the models were restricted to the clinical region, mFE still accurately predicted the measured failure load (R2 = 0.955, slope = 1.021), while hFE predictions were precise but tended to overpredict the failure load (R2 = 0.952, slope = 0.780). CONCLUSIONS It was concluded that it is possible to accurately predict the distal radius failure load using either mFE or hFE models when using the approaches and parameters developed in this study.
Collapse
Affiliation(s)
- A J Arias-Moreno
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, De Zaale, Groene Loper 15, 5612AP, Eindhoven, The Netherlands
- Department of Mechanics and Production, Autonomous University of Manizales, Antigua Estación del Ferrocarril, Manizales, Caldas, Colombia
| | - H S Hosseini
- Institute for Surgical Technology and Biomechanics, University of Bern, Stauffacherstrasse 78, 3014, Bern, Switzerland
| | - M Bevers
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, De Zaale, Groene Loper 15, 5612AP, Eindhoven, The Netherlands
| | - K Ito
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, De Zaale, Groene Loper 15, 5612AP, Eindhoven, The Netherlands
| | - P Zysset
- Institute for Surgical Technology and Biomechanics, University of Bern, Stauffacherstrasse 78, 3014, Bern, Switzerland
| | - B van Rietbergen
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, De Zaale, Groene Loper 15, 5612AP, Eindhoven, The Netherlands.
| |
Collapse
|