1
|
Dong RG, Wu JZ, Xu XS, Welcome DE, Krajnak K. A Review of Hand-Arm Vibration Studies Conducted by US NIOSH since 2000. VIBRATION 2021; 4:482-528. [PMID: 34414357 PMCID: PMC8371562 DOI: 10.3390/vibration4020030] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Studies on hand-transmitted vibration exposure, biodynamic responses, and biological effects were conducted by researchers at the Health Effects Laboratory Division (HELD) of the National Institute for Occupational Safety and Health (NIOSH) during the last 20 years. These studies are systematically reviewed in this report, along with the identification of areas where additional research is needed. The majority of the studies cover the following aspects: (i) the methods and techniques for measuring hand-transmitted vibration exposure; (ii) vibration biodynamics of the hand-arm system and the quantification of vibration exposure; (iii) biological effects of hand-transmitted vibration exposure; (iv) measurements of vibration-induced health effects; (iv) quantification of influencing biomechanical effects; and (v) intervention methods and technologies for controlling hand-transmitted vibration exposure. The major findings of the studies are summarized and discussed.
Collapse
Affiliation(s)
- Ren G. Dong
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| | - John Z. Wu
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| | - Xueyan S. Xu
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| | - Daniel E. Welcome
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| | - Kristine Krajnak
- Physical Effects Research Branch, Health Effects Laboratory Division (HELD), National Institute for Occupational Safety and Health (NIOSH), Morgantown, WV 26505, USA
| |
Collapse
|
2
|
Zhang X, Zhang Q, Li Y, Liu C, Qiu Y. Effect of the thickness of polyurethane foams at the seat pan and the backrest on fore-and-aft in-line and vertical cross-axis seat transmissibility when sitting with various contact conditions of backrest during fore-and-aft vibration. APPLIED ERGONOMICS 2021; 93:103354. [PMID: 33516943 DOI: 10.1016/j.apergo.2021.103354] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 12/24/2020] [Accepted: 12/30/2020] [Indexed: 06/12/2023]
Abstract
Ride comfort in vehicles can be affected by seat properties. While previous studies focused on the vertical whole-body vibration, this study was designed to understand the influence of the foam thickness at the seat pan and at the backrest on seat transmissibilities with fore-and-aft vibration. Twelve subjects sitting with or without a vertical backrest were exposed to random fore-and-aft vibration between 1 and 15 Hz with the magnitude of 0.5 ms-2 r.m.s.. It was found that there was no significant difference in the primary resonance frequencies in the fore-and-aft in-line and vertical cross-axis transmissibilities to the seat pan and to the backrest. The resonance frequency in the fore-and-aft in-line transmissibilities to the seat pan and the backrest decreased with increasing thickness of foam at the seat pan and the backrest. Altering the thickness of foam at the seat pan was more effective than changing that at the backrest.
Collapse
Affiliation(s)
- Xiaolu Zhang
- College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, China
| | - Qingyu Zhang
- College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, China
| | - Yuejuan Li
- College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, China
| | - Chi Liu
- Vehicle NVH and Refinement, Jaguar Land Rover, Gaydon, United Kingdom.
| | - Yi Qiu
- Dynamics Group, Institute of Sound and Vibration Research, University of Southampton, United Kingdom
| |
Collapse
|
3
|
Goggins KA, Tarabini M, Lievers WB, Eger TR. Biomechanical response of the human foot when standing in a natural position while exposed to vertical vibration from 10-200 Hz. ERGONOMICS 2019; 62:644-656. [PMID: 30560711 DOI: 10.1080/00140139.2018.1559362] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2017] [Revised: 12/03/2018] [Accepted: 12/08/2018] [Indexed: 06/09/2023]
Abstract
Exposure to foot-transmitted vibration (FTV) can lead to pain and numbness in the toes and feet, increased cold sensitivity, blanching in the toes, and joint pain. Prolonged exposure can result in a clinical diagnosis of vibration-induced white foot (VIWFt). Data on the biomechanical response of the feet to FTV is limited; therefore, this study seeks to identify resonant frequencies for different anatomical locations on the human foot, while standing in a natural position. A laser Doppler vibrometer was used to measure vertical (z-axis) vibration on 21 participants at 24 anatomical locations on the right foot during exposure to a sine sweep from 10-200 Hz with a peak vertical velocity of 30 mm/s. The most notable differences in the average peak frequency occur between the toes (range: 99-147 Hz), midfoot (range: 51-84 Hz) and ankle (range: 16-39 Hz). Practitioner Summary: The biomechanical response of the human foot exposed to foot-transmitted vibration, when standing in a natural position, was measured for 21 participants. The foot does not respond uniformly; the toes, midfoot, and ankle regions need to be considered independently in future development of isolation strategies and protective measures.
Collapse
Affiliation(s)
- Katie A Goggins
- a Bharti School of Engineering , Laurentian University , Sudbury , Canada
- b Centre for Research in Occupational Safety and Health , Laurentian University , Sudbury , Canada
| | - Marco Tarabini
- c Department of Mechanics , Politecnico di Milano , Lecco , Italy
| | - W Brent Lievers
- a Bharti School of Engineering , Laurentian University , Sudbury , Canada
- b Centre for Research in Occupational Safety and Health , Laurentian University , Sudbury , Canada
| | - Tammy R Eger
- b Centre for Research in Occupational Safety and Health , Laurentian University , Sudbury , Canada
- d School of Human Kinetics , Laurentian University , Sudbury , Canada
| |
Collapse
|
4
|
Pan D, Xu XS, Welcome DE, McDowell TW, Warren C, Wu J, Dong RG. The relationships between hand coupling force and vibration biodynamic responses of the hand-arm system. ERGONOMICS 2018; 61:818-830. [PMID: 29086628 PMCID: PMC6530558 DOI: 10.1080/00140139.2017.1398843] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Accepted: 10/20/2017] [Indexed: 06/07/2023]
Abstract
This study conducted two series of experiments to investigate the relationships between hand coupling force and biodynamic responses of the hand-arm system. In the first experiment, the vibration transmissibility on the system was measured as a continuous function of grip force while the hand was subjected to discrete sinusoidal excitations. In the second experiment, the biodynamic responses of the system subjected to a broadband random vibration were measured under five levels of grip forces and a combination of grip and push forces. This study found that the transmissibility at each given frequency increased with the increase in the grip force before reaching a maximum level. The transmissibility then tended to plateau or decrease when the grip force was further increased. This threshold force increased with an increase in the vibration frequency. These relationships remained the same for both types of vibrations. The implications of the experimental results are discussed. Practitioner Summary: Shocks and vibrations transmitted to the hand-arm system may cause injuries and disorders of the system. How to take hand coupling force into account in the risk assessment of vibration exposure remains an important issue for further studies. This study is designed and conducted to help resolve this issue.
Collapse
Affiliation(s)
- Daniel Pan
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , WV , USA
| | - Xueyan S Xu
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , WV , USA
| | - Daniel E Welcome
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , WV , USA
| | - Thomas W McDowell
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , WV , USA
| | - Christopher Warren
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , WV , USA
| | - John Wu
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , WV , USA
| | - Ren G Dong
- a Engineering and Control Technology Branch, Health Effects Laboratory Division , National Institute for Occupational Safety and Health , Morgantown , WV , USA
| |
Collapse
|
5
|
Xu XS, Dong RG, Welcome DE, Warren C, McDowell TW, Wu JZ. Vibrations transmitted from human hands to upper arm, shoulder, back, neck, and head. INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS 2017; 62:1-12. [PMID: 29123326 PMCID: PMC5672949 DOI: 10.1016/j.ergon.2016.07.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
UNLABELLED Some powered hand tools can generate significant vibration at frequencies below 25 Hz. It is not clear whether such vibration can be effectively transmitted to the upper arm, shoulder, neck, and head and cause adverse effects in these substructures. The objective of this study is to investigate the vibration transmission from the human hands to these substructures. Eight human subjects participated in the experiment, which was conducted on a 1-D vibration test system. Unlike many vibration transmission studies, both the right and left hand-arm systems were simultaneously exposed to the vibration to simulate a working posture in the experiment. A laser vibrometer and three accelerometers were used to measure the vibration transmitted to the substructures. The apparent mass at the palm of each hand was also measured to help in understanding the transmitted vibration and biodynamic response. This study found that the upper arm resonance frequency was 7-12 Hz, the shoulder resonance was 7-9 Hz, and the back and neck resonances were 6-7 Hz. The responses were affected by the hand-arm posture, applied hand force, and vibration magnitude. The transmissibility measured on the upper arm had a trend similar to that of the apparent mass measured at the palm in their major resonant frequency ranges. The implications of the results are discussed. RELEVANCE TO INDUSTRY Musculoskeletal disorders (MSDs) of the shoulder and neck are important issues among many workers. Many of these workers use heavy-duty powered hand tools. The combined mechanical loads and vibration exposures are among the major factors contributing to the development of MSDs. The vibration characteristics of the body segments examined in this study can be used to help understand MSDs and to help develop more effective intervention methods.
Collapse
Affiliation(s)
- Xueyan S. Xu
- Corresponding author. ECTB/HELD/NIOSH/CDC, 1095 Willowdale Road, MS L-2027, Morgantown, WV 26505, USA. (X.S. Xu)
| | | | | | | | | | | |
Collapse
|
6
|
Dong RG, Sinsel EW, Welcome DE, Warren C, Xu XS, McDowell TW, Wu JZ. Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces. Saf Health Work 2016; 6:159-73. [PMID: 26929824 PMCID: PMC4674512 DOI: 10.1016/j.shaw.2015.05.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Accepted: 06/28/2015] [Indexed: 11/29/2022] Open
Abstract
The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.
Collapse
Affiliation(s)
- Ren G Dong
- Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA
| | - Erik W Sinsel
- Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA
| | - Daniel E Welcome
- Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA
| | - Christopher Warren
- Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA
| | - Xueyan S Xu
- Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA
| | - Thomas W McDowell
- Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA
| | - John Z Wu
- Engineering & Control Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV, USA
| |
Collapse
|
7
|
Dong RG, Welcome DE, McDowell TW, Wu JZ. Theoretical foundation, methods, and criteria for calibrating human vibration models using frequency response functions. JOURNAL OF SOUND AND VIBRATION 2015; 356:195-216. [PMID: 26740726 PMCID: PMC4699322 DOI: 10.1016/j.jsv.2015.06.047] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
While simulations of the measured biodynamic responses of the whole human body or body segments to vibration are conventionally interpreted as summaries of biodynamic measurements, and the resulting models are considered quantitative, this study looked at these simulations from a different angle: model calibration. The specific aims of this study are to review and clarify the theoretical basis for model calibration, to help formulate the criteria for calibration validation, and to help appropriately select and apply calibration methods. In addition to established vibration theory, a novel theorem of mechanical vibration is also used to enhance the understanding of the mathematical and physical principles of the calibration. Based on this enhanced understanding, a set of criteria was proposed and used to systematically examine the calibration methods. Besides theoretical analyses, a numerical testing method is also used in the examination. This study identified the basic requirements for each calibration method to obtain a unique calibration solution. This study also confirmed that the solution becomes more robust if more than sufficient calibration references are provided. Practically, however, as more references are used, more inconsistencies can arise among the measured data for representing the biodynamic properties. To help account for the relative reliabilities of the references, a baseline weighting scheme is proposed. The analyses suggest that the best choice of calibration method depends on the modeling purpose, the model structure, and the availability and reliability of representative reference data.
Collapse
Affiliation(s)
- Ren G. Dong
- Correspondence to: ECTB/HELD/NIOSH/CDC, 1095 Willowdale Road, MS L-2027, Morgantown, WV 26505, USA. Tel.: +1 304 285 6332; fax: +1 304 285 6265. (R.G. Dong)
| | | | | | | |
Collapse
|
8
|
Xu XS, Dong RG, Welcome DE, Warren C, McDowell TW. An examination of an adapter method for measuring the vibration transmitted to the human arms. MEASUREMENT : JOURNAL OF THE INTERNATIONAL MEASUREMENT CONFEDERATION 2015; 73:318-334. [PMID: 26834309 PMCID: PMC4731869 DOI: 10.1016/j.measurement.2015.05.039] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The objective of this study is to evaluate an adapter method for measuring the vibration on the human arms. Four instrumented adapters with different weights were used to measure the vibration transmitted to the wrist, forearm, and upper arm of each subject. Each adapter was attached at each location on the subjects using an elastic cloth wrap. Two laser vibrometers were also used to measure the transmitted vibration at each location to evaluate the validity of the adapter method. The apparent mass at the palm of the hand along the forearm direction was also measured to enhance the evaluation. This study found that the adapter and laser-measured transmissibility spectra were comparable with some systematic differences. While increasing the adapter mass reduced the resonant frequency at the measurement location, increasing the tightness of the adapter attachment increased the resonant frequency. However, the use of lightweight (≤15 g) adapters under medium attachment tightness did not change the basic trends of the transmissibility spectrum. The resonant features observed in the transmissibility spectra were also correlated with those observed in the apparent mass spectra. Because the local coordinate systems of the adapters may be significantly misaligned relative to the global coordinates of the vibration test systems, large errors were observed for the adapter-measured transmissibility in some individual orthogonal directions. This study, however, also demonstrated that the misalignment issue can be resolved by either using the total vibration transmissibility or by measuring the misalignment angles to correct the errors. Therefore, the adapter method is acceptable for understanding the basic characteristics of the vibration transmission in the human arms, and the adapter-measured data are acceptable for approximately modeling the system.
Collapse
Affiliation(s)
- Xueyan S. Xu
- Corresponding author at: ECTB/HELD/NIOSH/CDC, 1095 Willowdale Road, MS L-2027, Morgantown, WV 26505, USA. Tel.: +1 (304) 285 5840; fax: +1 (304) 285 6265. (X.S. Xu)
| | | | | | | | | |
Collapse
|
9
|
Welcome DE, Dong RG, Xu XS, Warren C, McDowell TW, Wu JZ. An examination of the vibration transmissibility of the hand-arm system in three orthogonal directions. INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS 2015; 45:21-34. [PMID: 26635424 PMCID: PMC4666322 DOI: 10.1016/j.ergon.2014.11.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
UNLABELLED The objective of this study is to enhance the understanding of the vibration transmission in the hand-arm system in three orthogonal directions (X, Y, and Z). For the first time, the transmitted vibrations distributed on the entire hand-arm system exposed in the three orthogonal directions via a 3-D vibration test system were measured using a 3-D laser vibrometer. Seven adult male subjects participated in the experiment. This study confirms that the vibration transmissibility generally decreased with the increase in distance from the hand and it varied with the vibration direction. Specifically, to the upper arm and shoulder, only moderate vibration transmission was measured in the test frequency range (16 to 500 Hz), and virtually no transmission was measured in the frequency range higher than 50 Hz. The resonance vibration on the forearm was primarily in the range of 16-30 Hz with the peak amplitude of approximately 1.5 times of the input vibration amplitude. The major resonance on the dorsal surfaces of the hand and wrist occurred at around 30-40 Hz and, in the Y direction, with peak amplitude of more than 2.5 times of the input amplitude. At higher than 50 Hz, vibration transmission was effectively limited to the hand and fingers. A major finger resonance was observed at around 100 Hz in the X and Y directions and around 200 Hz in the Z direction. In the fingers, the resonance magnitude in the Z direction was generally the lowest, and the resonance magnitude in the Y direction was generally the highest with the resonance amplitude of 3 times the input vibration, which was similar to the transmissibility at the wrist and hand dorsum. The implications of the results are discussed. RELEVANCE TO INDUSTRY Prolonged, intensive exposure to hand-transmitted vibration could result in hand-arm vibration syndrome. While the syndrome's precise mechanisms remain unclear, the characterization of the vibration transmissibility of the system in the three orthogonal dimensions performed in this study can help understand the syndrome and help develop improved frequency weightings for assessing the risk of the exposure for developing various components of the syndrome.
Collapse
Affiliation(s)
| | - Ren G. Dong
- Corresponding author. ECTB/HELD/NIOSH/CDC, 1095 Willowdale Road, MS L-2027, Morgantown, WV 26505, USA. Tel.: +1 304 285 6332; fax: +1 304 285 6265. (R.G. Dong)
| | | | | | | | | |
Collapse
|