Donato F, Donati T, Minelli F, Borghetti A, Minucci M, Luparelli A, Tinelli G, Tshomba Y. Treatment of Aorto-iliac and Infrainguinal Vascular Infections with a Prefabricated Bovine Pericardial Graft. Ann Vasc Surg 2024; 105:177-188. [PMID: 38599483 DOI: 10.1016/j.avsg.2024.01.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Revised: 12/30/2023] [Accepted: 01/01/2024] [Indexed: 04/12/2024]
Abstract
BACKGROUND The use of biological grafts provides acceptable mid- and long-term results in native or prosthetic vascular infections. Several reports describe the successful use of bovine pericardium in case of vascular infections, mainly as a large patch to be sutured as a tubular graft. Recently, a novel prefabricated bovine pericardium graft (Biointegral Surgical No-React® Inc, Mississauga, ON, Canada) has been introduced in clinical practice with promising results. In this study, we report our preliminary experience utilizing Biointegral Surgical graft in case of native and or prosthetic aorto-iliac and infrainguinal infection. METHODS We retrospectively analyzed data from 20 patients with native or prosthetic aorto-iliac and infrainguinal infection who underwent in situ reconstruction (ISR) with a Biointegral Surgical No-React bovine pericardium prosthesis between October 2020 and February 2023 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario Gemelli - IRCCS in Rome, Italy. All patients followed a standardized protocol including postoperative anticoagulation and long-term intravenous antibiotics. RESULTS The indication for surgery was: mycotic aortic aneurysm in 4 patients (20%), graft infection after abdominal aortic repair in 11 patients (55%), peripheral graft infection in 5 patients (25%). Complete excision of the infected aorta or prosthetic graft, surgical debridement and ISR were performed in all patients. Hospital mortality rate was 5% (n = 1) and graft-related mortality of 0%. During follow-up (median 13 months, range 6-34 months), reinfection was 5.2% and primary graft patency 94.7%. CONCLUSIONS The use of prefabricated bovine pericardial grafts represents a promising option for the treatment of native and prosthetic aorto-iliac and infrainguinal infections. The application of this biological graft with a standardized postoperative protocol has been associated with a satisfactory patency and reinfection rate without increased bleeding complications.
Collapse
Affiliation(s)
- Federica Donato
- Dipartimento Cardiovascolare, Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Vascular Surgery, Fondazione Policlinico Universitario Gemelli IRCCS, Roma - Università Cattolica del Sacro Cuore, Rome, Italy.
| | - Tommaso Donati
- Dipartimento Cardiovascolare, Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Vascular Surgery, Fondazione Policlinico Universitario Gemelli IRCCS, Roma - Università Cattolica del Sacro Cuore, Rome, Italy
| | - Fabrizio Minelli
- Dipartimento Cardiovascolare, Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Vascular Surgery, Fondazione Policlinico Universitario Gemelli IRCCS, Roma - Università Cattolica del Sacro Cuore, Rome, Italy
| | - Alberto Borghetti
- Dipartimento Cardiovascolare, Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Infectious Diseases, Fondazione Policlinico Universitario Gemelli IRCCS, Roma - Università Cattolica del Sacro Cuore, Rome, Italy
| | - Marta Minucci
- Dipartimento Cardiovascolare, Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Vascular Surgery, Fondazione Policlinico Universitario Gemelli IRCCS, Roma - Università Cattolica del Sacro Cuore, Rome, Italy
| | - Antonio Luparelli
- Dipartimento Cardiovascolare, Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Vascular Surgery, Fondazione Policlinico Universitario Gemelli IRCCS, Roma - Università Cattolica del Sacro Cuore, Rome, Italy
| | - Giovanni Tinelli
- Dipartimento Cardiovascolare, Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Vascular Surgery, Fondazione Policlinico Universitario Gemelli IRCCS, Roma - Università Cattolica del Sacro Cuore, Rome, Italy
| | - Yamume Tshomba
- Dipartimento Cardiovascolare, Università Cattolica del Sacro Cuore, Rome, Italy; Unit of Vascular Surgery, Fondazione Policlinico Universitario Gemelli IRCCS, Roma - Università Cattolica del Sacro Cuore, Rome, Italy
| |
Collapse
|
2
|
Botea R, Lavie-Badie Y, Goicea A, Porterie J, Marcheix B. Early and midterm outcomes of a bentall operation using an all-biological valved BioConduit™. J Cardiothorac Surg 2022; 17:325. [PMID: 36536442 PMCID: PMC9761648 DOI: 10.1186/s13019-022-02073-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Accepted: 12/09/2022] [Indexed: 12/23/2022] Open
Abstract
OBJECTIVES To analyze the midterm results of aortic root replacement using the valved, all biological, No React®, BioConduit™. METHODS From 2017 to 2020, we prospectively followed 91 consecutive patients who underwent a Bentall procedure with a BioConduit™ valved graft in our institution. The primary outcomes were aortic bioprosthetic valve dysfunction and mortality according to Valve Academic Research Consortium 3 (VARC3). RESULTS Mean age was 70 ± 10 years and 67 patients (74%) were men. Ascending aortic aneurysm (72%), aortic valve regurgitation (51%) or stenosis (20%) and acute endocarditis (14%) were the main indications for surgery. Seventy-four patients (81.3%) were followed up at 1 year. The perioperative mortality was 8% (n = 8), the early, 1 year, mortality was 2% (n = 2) and the midterm mortality, at 4 years of follow up, was 4% (n = 3). Ten patients fulfilled the criteria for hemodynamic valve deterioration at 1 year (13%) and 14 for a bioprosthetic valve failure during the entire follow-up (17%). CONCLUSIONS We are reporting early and midterm results of Bentall procedures with the all-biological, valved, No-React® BioConduit™. To our knowledge, this is the first study reporting an early and midterm unexpectedly high rate of non-structural prosthetic hemodynamic deterioration. The rate of endocarditis and atrioventricular disconnections remain similar to previous studies.
Collapse
Affiliation(s)
- Roxana Botea
- grid.414295.f0000 0004 0638 3479Department of Cardiovascular Surgery, Rangueil University Hospital, Toulouse, France ,grid.414295.f0000 0004 0638 3479Department of Cardiology, Rangueil University Hospital, 1, Avenue Jean Poulhès, TSA 50032, 31059 Toulouse Cedex, France
| | - Yoan Lavie-Badie
- grid.414295.f0000 0004 0638 3479Department of Cardiology, Rangueil University Hospital, 1, Avenue Jean Poulhès, TSA 50032, 31059 Toulouse Cedex, France
| | - Alexandru Goicea
- grid.414295.f0000 0004 0638 3479Department of Cardiovascular Surgery, Rangueil University Hospital, Toulouse, France ,Department of Cardiovascular Surgery, Nicolae Stancioiu Heart Institute, Cluj-Napoca, Romania
| | - Jean Porterie
- grid.414295.f0000 0004 0638 3479Department of Cardiovascular Surgery, Rangueil University Hospital, Toulouse, France
| | - Bertrand Marcheix
- grid.414295.f0000 0004 0638 3479Department of Cardiovascular Surgery, Rangueil University Hospital, Toulouse, France
| |
Collapse
|
3
|
Rapetto F, Caputo M, Angelini GD. Surgical reconstruction of the right ventricular outflow tract-The clock is still ticking. J Card Surg 2021; 36:3153-3154. [PMID: 34057241 DOI: 10.1111/jocs.15685] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 05/21/2021] [Indexed: 11/29/2022]
Affiliation(s)
| | - Massimo Caputo
- Bristol Heart Institute, University of Bristol, Bristol, UK
| | | |
Collapse
|
4
|
Selcuk A, Kilic Y, Korun O, Yurdakok O, Cicek M, Altin HF, Altuntas Y, Yilmaz EH, Sasmazel A, Aydemir NA. High incidence of fever in patients after biointegral pulmonic valved conduit implantation. J Card Surg 2021; 36:3147-3152. [PMID: 34056764 DOI: 10.1111/jocs.15683] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 04/02/2021] [Accepted: 05/03/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To describe our short- and medium-term outcomes using the BioIntegral pulmonic conduit. METHODS Between August 2018 and September 2019, the BioIntegral pulmonic valved conduit was used for right ventricular outflow tract reconstruction in 48 patients. The data were retrospectively retrieved from the patient charts. RESULTS The median age at surgery was 36 months (interquartile range [IQR] = 18-62 months). The diagnoses were pulmonary atresia-ventricular septal defect in 28 patients, absent pulmonary valve in four patients, truncus arteriosus in six patients, TGA-VSD-PS in five patients, conduit stenosis in three patients, and left venticular outflow tract obstruction requiring a Ross operation in two patients. In the postoperative short-term follow-up, 15 patients out of 48 had a high fever. Of these, 12 patients had concomitantly elevated C-reactive protein levels. There were no patients with blood culture positivity. The median postoperative length of hospital stay was 14 days (IQR = 8-21 days). The overall mortality was 4% in two patients, one died of right ventricular failure and multiple organ failure and one died of pulmonary embolism. The two patients who died were not among the 15 patients with fever. However, four patients with fever underwent balloon angioplasty for conduit restenosis in their medium-term follow-up. CONCLUSION There was a high incidence of fever and adverse outcomes in the short-term postoperative follow-up of patients in whom the BioIntegral pulmonic valved conduit was implanted. Caution is advisable in using these conduits until there is convincing evidence about the sterilization and storage standards of these grafts.
Collapse
Affiliation(s)
- Arif Selcuk
- Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| | - Yigit Kilic
- Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| | - Oktay Korun
- Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| | - Okan Yurdakok
- Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| | - Murat Cicek
- Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| | - Husnu F Altin
- Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| | - Yasemin Altuntas
- Department of Anesthesiology and Reanimation, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| | - Emine H Yilmaz
- Department of Pediatric Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| | - Ahmet Sasmazel
- Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| | - Numan A Aydemir
- Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
| |
Collapse
|
5
|
Le Bars F, Tomasi J, Belhaj Soulami R, Colas F, Anselmi A, Verhoye JP. Long-term follow-up of the Shelhigh™ superstentless bioprosthesis aortic valve and valved conduit in a monocentric experience. THE JOURNAL OF CARDIOVASCULAR SURGERY 2020; 61:776-783. [PMID: 32558524 DOI: 10.23736/s0021-9509.20.11219-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The Shelhigh™ SuperStentless (Shelhigh, INC., Union, NJ, USA) is a stentless aortic valve bioprosthesis and aortic root valved conduit. In 2007, this device was recalled by FDA due to malfunction, and subsequently reintegrated by BioIntegral Surgical™ Few data are available over late durability of this device. We performed a long-term follow-up of Shelhigh™ devices implanted at our center. METHODS Between 2002 and 2007, 44 patients underwent aortic valve replacement with a Shelhigh™ device (40 aortic valve bioprosthesis and 4 valved conduit). We performed a clinical and echocardiographic follow-up (9.2 years±4.3). Standardized definitions of valve-related events were adopted. RESULTS At discharge, maximum and mean aortic gradients averaged 36.1±11.3 and 21.0±6.8 mmHg, respectively. The 30-days mortality was 2.3%. Over the follow-up period, 29 patients died (65.9%); 2 deaths were valve related. Overall survival at 1, 5 and 10 years was 97.7%, 85.8% and 54% respectively. At last echocardiography, average transvalvular gradients had remained globally stable in the population (33.6±12 and 20.4±10.5 mmHg). Eight (19%) structural valve deterioration (SVD) events were reported. Two (5%) non-structural valve dysfunction (NSVD) events occurred (periprosthetic leak). Two (5%) infectious endocarditis events and two (5%) valve thromboses were also deplored. Three (7%) patients required re-operation (2 due to SVD and 1 due to endocarditis). CONCLUSIONS The immediate hemodynamic performance of the Shelhigh™ aortic bioprostheses was unexpectedly suboptimal. Despite this, hemodynamic performance remained stable over time. Patients survival at follow-up was satisfactory, however, continued surveillance is necessary.
Collapse
Affiliation(s)
- Florent Le Bars
- Division of Thoracic and Cardiovascular Surgery, Pontchaillou University Hospital Center, Rennes, France
| | - Jacques Tomasi
- Division of Thoracic and Cardiovascular Surgery, Pontchaillou University Hospital Center, Rennes, France
| | - Reda Belhaj Soulami
- Division of Thoracic and Cardiovascular Surgery, Pontchaillou University Hospital Center, Rennes, France
| | - Fabrice Colas
- Division of Thoracic and Cardiovascular Surgery, Pontchaillou University Hospital Center, Rennes, France
| | - Amedeo Anselmi
- Division of Thoracic and Cardiovascular Surgery, Pontchaillou University Hospital Center, Rennes, France -
| | - Jean-Philippe Verhoye
- Division of Thoracic and Cardiovascular Surgery, Pontchaillou University Hospital Center, Rennes, France
| |
Collapse
|
6
|
Roubelakis A, Karangelis D, Sadeque S, Yanagawa B, Modi A, Barlow CW, Livesey SA, Ohri SK. Initial experience with xenograft bioconduit for the treatment of complex prosthetic valve endocarditis. Perfusion 2017; 32:383-388. [PMID: 28118782 DOI: 10.1177/0267659117690250] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
INTRODUCTION The treatment of complex prosthetic valve endocarditis (PVE) with aortic root abscess remains a surgical challenge. Several studies support the use of biological tissues to minimize the risk of recurrent infection. We present our initial surgical experience with the use of an aortic xenograft conduit for aortic valve and root replacement. METHODS Between October 2013 and August 2015, 15 xenograft bioconduits were implanted for complex PVE with abscess (13.3% female). In 6 patients, concomitant procedures were performed: coronary bypass (n=1), mitral valve replacement (n=5) and tricuspid annuloplasty (n=1). The mean age at operation was 60.3±15.5 years. The mean Logistic European system for cardiac operating risk evaluation (EuroSCORE) was 46.6±23.6. The median follow-up time was 607±328 days (range: 172-1074 days). RESULTS There were two in-hospital deaths (14.3% mortality), two strokes (14.3%) and seven patients required permanent pacemaker insertion for conduction abnormalities (46.7%). The mean length of hospital stay was 26 days. At pre-discharge echocardiography, the conduit mean gradient was 9.3±3.3mmHg and there was either none (n=6), trace (n=6) or mild aortic insufficiency (n=1). There was no incidence of mid-term death, prosthesis-related complications or recurrent endocarditis. CONCLUSIONS Xenograft bioconduits may be safe and effective for aortic valve and root replacement for complex PVE with aortic root abscess. Although excess early mortality reflects the complexity of the patient population, there was good valve hemodynamics, with no incidence of recurrent endocarditis or prosthesis failure in the mid-term. Our data support the continued use and evaluation of this biological prosthesis in this high-risk patient cohort.
Collapse
Affiliation(s)
- Apostolos Roubelakis
- 1 Department of Cardiac Surgery, University Hospital Southampton, Southampton, UK
| | - Dimos Karangelis
- 2 Division of Cardiac Surgery, St Michael's Hospital, University of Toronto, Toronto, Canada
| | - Syed Sadeque
- 1 Department of Cardiac Surgery, University Hospital Southampton, Southampton, UK
| | - Bobby Yanagawa
- 2 Division of Cardiac Surgery, St Michael's Hospital, University of Toronto, Toronto, Canada
| | - Amit Modi
- 1 Department of Cardiac Surgery, University Hospital Southampton, Southampton, UK
| | - Clifford W Barlow
- 1 Department of Cardiac Surgery, University Hospital Southampton, Southampton, UK
| | - Steven A Livesey
- 1 Department of Cardiac Surgery, University Hospital Southampton, Southampton, UK
| | - Sunil K Ohri
- 1 Department of Cardiac Surgery, University Hospital Southampton, Southampton, UK
| |
Collapse
|
7
|
Carrel T, Reineke D, Englberger L. Another report on unfavourable long-term outcome following implantation of the Shelhigh No-React™ valved tube graft. Eur J Cardiothorac Surg 2016; 50:1179-1180. [PMID: 27307482 DOI: 10.1093/ejcts/ezw205] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Thierry Carrel
- Department of Cardiovascular Surgery, University Hospital and University of Bern, Bern, Switzerland
| | - David Reineke
- Department of Cardiovascular Surgery, University Hospital and University of Bern, Bern, Switzerland
| | - Lars Englberger
- Department of Cardiovascular Surgery, University Hospital and University of Bern, Bern, Switzerland
| |
Collapse
|
8
|
Sahin A, Müggler O, Sromicki J, Caliskan E, Reser D, Emmert MY, Alkadhi H, Maisano F, Falk V, Holubec T. Long-term follow-up after aortic root replacement with the Shelhigh® biological valved conduit: a word of caution! Eur J Cardiothorac Surg 2016; 50:1172-1178. [DOI: 10.1093/ejcts/ezw167] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2015] [Revised: 04/02/2016] [Accepted: 04/13/2016] [Indexed: 11/13/2022] Open
|
9
|
Reineke DC, Kaya A, Heinisch PP, Oezdemir B, Winkler B, Huber C, Heijmen RH, Morshuis W, Carrel TP, Englberger L. Long-term follow-up after implantation of the Shelhigh® No-React® complete biological aortic valved conduit. Eur J Cardiothorac Surg 2015; 50:98-104. [DOI: 10.1093/ejcts/ezv452] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Accepted: 11/26/2015] [Indexed: 11/12/2022] Open
|
10
|
Assessment of Hemodynamic Conditions in the Aorta Following Root Replacement with Composite Valve-Conduit Graft. Ann Biomed Eng 2015; 44:1392-404. [PMID: 26369636 DOI: 10.1007/s10439-015-1453-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Accepted: 09/07/2015] [Indexed: 10/23/2022]
Abstract
This paper presents the analysis of detailed hemodynamics in the aortas of four patients following replacement with a composite bio-prosthetic valve-conduit. Magnetic resonance image-based computational models were set up for each patient with boundary conditions comprising subject-specific three-dimensional inflow velocity profiles at the aortic root and central pressure waveform at the model outlet. Two normal subjects were also included for comparison. The purpose of the study was to investigate the effects of the valve-conduit on flow in the proximal and distal aorta. The results suggested that following the composite valve-conduit implantation, the vortical flow structure and hemodynamic parameters in the aorta were altered, with slightly reduced helical flow index, elevated wall shear stress and higher non-uniformity in wall shear compared to normal aortas. Inter-individual analysis revealed different hemodynamic conditions among the patients depending on the conduit configuration in the ascending aorta, which is a key factor in determining post-operative aortic flow. Introducing a natural curvature in the conduit to create a smooth transition between the conduit and native aorta may help prevent the occurrence of retrograde and recirculating flow in the aortic arch, which is particularly important when a large portion or the entire ascending aorta needs to be replaced.
Collapse
|
11
|
Aortic Root Replacement With Biological Valved Conduits. Ann Thorac Surg 2015; 100:337-53. [DOI: 10.1016/j.athoracsur.2015.02.057] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Revised: 02/06/2015] [Accepted: 02/12/2015] [Indexed: 11/24/2022]
|
12
|
First 102 Patients With the Biovalsalva Conduit for Aortic Root Replacement. Ann Thorac Surg 2012; 94:72-7. [DOI: 10.1016/j.athoracsur.2012.03.032] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2012] [Revised: 03/09/2012] [Accepted: 03/19/2012] [Indexed: 11/17/2022]
|
13
|
Lepage L, Krapf L, Hekimian G, Duval X, Nataf P, Hvass U, Vahanian A, Messika-Zeitoun D. Unusual presentation of cryolife O'Brien(R) stentless aortic valve bioprosthesis dysfunction mimicking infective endocarditis. Eur J Cardiothorac Surg 2011; 41:800-5. [PMID: 22219468 DOI: 10.1093/ejcts/ezr191] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVES We previously reported a possible but unusual prosthetic-valve infective endocarditis (PV-IE) occurring on a Cryolife O'Brien Stentless Porcine Xenograft (CLOB) (anatomic damages suggestive of IE but negative inflammatory and microbiological markers). We reviewed all cases of aortic PV-IE admitted in our institution and compared the clinical presentation, bacteriological and echocardiographic features according to the type of prosthesis. METHODS Sixty consecutive cases with possible or definite aortic PV-IE (23 CLOB, 26 mechanical valve and 11 stented bioprosthesis) were admitted between 2002 and 2008. RESULTS Patients with CLOB had more prosthetic dehiscence (P = 0.006) and severe regurgitation (P = 0.01) than those with mechanical or stented prosthetic valves. In contrast, they had less fever (P = 0.003), lower C-reactive protein (CRP) levels (P = 0.02) and more frequently negative blood cultures (P = 0.08). Differences were due to seven patients who presented with no fever, low CRP, negative blood culture, negative valve culture and PCR when performed, despite echocardiographic features suggestive of IE (abscess or valve dehiscence). All were first operated on since 2004 when the manufacturing process changed and required a second surgery. The French Authority of Health was informed leading to the withdrawal of the CLOB from the market in 2010. CONCLUSIONS One-third of patients with CLOB admitted for possible or definite PV-IE presented with anatomic damages suggestive of IE but with negative inflammatory and microbiological markers. The exact aetiology remains unclear, but the present data have led to the worldwide withdrawal of prosthesis in 2010. A close follow-up of patients implanted with CLOB should be advised, especially if it has been manufactured since 2004.
Collapse
Affiliation(s)
- Laurent Lepage
- Department of Cardiac Surgery, AP-HP, Bichat Hospital, Paris, France
| | | | | | | | | | | | | | | |
Collapse
|