Langer N, Stephens AF, Šeman M, McGiffin D, Kaye DM, Gregory SD. HeartMate 3 for Heart Failure with Preserved Ejection Fraction: In Vitro Hemodynamic Evaluation and Anatomical Fitting. Ann Biomed Eng 2024:10.1007/s10439-024-03585-y. [PMID: 39014052 DOI: 10.1007/s10439-024-03585-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 07/08/2024] [Indexed: 07/18/2024]
Abstract
Heart failure with preserved ejection fraction (HFpEF) constitutes approximately 50% of heart failure (HF) cases, and encompasses different phenotypes. Among these, most patients with HFpEF exhibit structural heart changes, often with smaller left ventricular cavities, which pose challenges for utilizing ventricular assist devices (VADs). A left atrial to aortic (LA-Ao) VAD configuration could address these challenges, potentially enhancing patient quality of life by lowering elevated mean left atrial pressure (MLAP). This study assessed the anatomical compatibility and left atrial unloading capacity using a simulated VAD-supported HFpEF patient. A HeartMate3-supported HFpEF patient in an LA-Ao configuration was simulated using a cardiovascular simulator. Hemodynamic parameters were recorded during rest and exercise at seven pump flow rates. Computed tomography scans of 14 HFpEF (NYHA II-III) and six heart failure with reduced ejection fraction patients were analysed for anatomical comparisons. HFpEF models were independently assessed for virtual anatomical fit with the HM3 in the LA-Ao configuration. Baseline MLAP was reduced from 15 to 11 mmHg with the addition of 1 L/min HM3 support in the rest condition. In an exercise simulation, 6 L/min of HM3 support was required to reduce the MLAP from 29 to 16 mmHg. The HM3 successfully accommodated six HFpEF patients without causing interference with other cardiac structures, whereas it caused impingement ranging from 4 to 14 mm in the remaining patients. This study demonstrated that the HM3 in an LA-Ao configuration may be suitable for unloading the left atrium and relieving pulmonary congestion in some HFpEF patients where size-related limitations can be addressed through pre-surgical anatomical fit analysis.
Collapse
Affiliation(s)
- Nina Langer
- Cardio-Respiratory Engineering and Technology Laboratory (CREATElab), Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia.
- Victorian Heart Institute, Victorian Heart Hospital, Melbourne, VIC, Australia.
- Victorian Heart Hospital, Melbourne, VIC, Australia.
| | - Andrew F Stephens
- Cardio-Respiratory Engineering and Technology Laboratory (CREATElab), Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia
- Victorian Heart Institute, Victorian Heart Hospital, Melbourne, VIC, Australia
| | - Michael Šeman
- Cardio-Respiratory Engineering and Technology Laboratory (CREATElab), Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia
- School of Public Health and Preventative Medicine, Monash University, Melbourne, VIC, Australia
- The Department of Cardiology, The Alfred Hospital, Melbourne, VIC, Australia
| | - David McGiffin
- Department of Cardiothoracic Surgery, The Alfred, Melbourne, VIC, Australia
| | - David M Kaye
- The Department of Cardiology, The Alfred Hospital, Melbourne, VIC, Australia
| | - Shaun D Gregory
- Cardio-Respiratory Engineering and Technology Laboratory (CREATElab), Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, VIC, Australia
- Victorian Heart Institute, Victorian Heart Hospital, Melbourne, VIC, Australia
| |
Collapse
|
2
|
He X, Bender M, Gross C, Narayanaswamy K, Laufer G, Jakubek S, Bonderman D, Roehrich M, Karner B, Zimpfer D, Granegger M. Left Atrial Decompression With the HeartMate3 in Heart Failure With Preserved Ejection Fraction: Virtual Fitting and Hemodynamic Analysis. ASAIO J 2024; 70:107-115. [PMID: 37831817 DOI: 10.1097/mat.0000000000002074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2023] Open
Abstract
Effective treatment of heart failure with preserved ejection fraction (HFpEF) remains an unmet medical need. Although left atrial decompression using mechanical circulatory support devices was previously suggested, the heterogeneous HFpEF population and the lack of tailored devices have prevented the translation into clinical practice. This study aimed to evaluate the feasibility of left atrial decompression in HFpEF patients with a HeartMate 3 (HM3, Abbott Inc, Chicago, USA) in silico and in vitro . Anatomic compatibility of the HM3 pump was assessed by virtual device implantation into the left atrium through the left atrial appendage (LAA) and left atrial posterior wall (LAPW) of 10 HFpEF patients. Further, the efficacy of left atrial decompression was investigated experimentally in a hybrid mock loop, replicating the hemodynamics of an HFpEF phenotype at rest and exercise conditions. Virtual implantation without substantial intersection with surrounding tissues was accomplished through the LAA in 90% and 100% through the LAPW. Hemodynamic analysis in resting conditions demonstrated normalization of left atrial pressures without backflow at a pump speed of around 5400 rpm, whereas a range of 6400-7400 rpm was required during exercise. Therefore, left atrial decompression with the HM3 may be feasible in terms of anatomic compatibility and hemodynamic efficacy.
Collapse
Affiliation(s)
- Xiangyu He
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Moritz Bender
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
- Division of Control and Process Automation, Institute of Mechanics and Mechatronics, TU Wien, Vienna, Austria
| | - Christoph Gross
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | | | - Günther Laufer
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Stefan Jakubek
- Division of Control and Process Automation, Institute of Mechanics and Mechatronics, TU Wien, Vienna, Austria
| | | | - Michael Roehrich
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| | - Barbara Karner
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
- Division of Cardiac Surgery, Department of Surgery, Medical University of Graz, Graz, Austria
| | - Daniel Zimpfer
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
- Division of Cardiac Surgery, Department of Surgery, Medical University of Graz, Graz, Austria
| | - Marcus Granegger
- From the Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
3
|
Miyagi C, Kuban BD, Flick CR, Polakowski AR, Miyamoto T, Karimov JH, Starling RC, Fukamachi K. Left atrial assist device for heart failure with preserved ejection fraction: initial results with torque control mode in diastolic heart failure model. Heart Fail Rev 2023; 28:287-296. [PMID: 33931816 DOI: 10.1007/s10741-021-10117-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 04/26/2021] [Indexed: 12/29/2022]
Abstract
A novel pump, the left atrial assist device (LAAD), is a device specifically for the treatment of heart failure with preserved ejection fraction (HFpEF). The LAAD is a mixed-flow pump that is implanted in the mitral position and delivers blood from the left atrium to the left ventricle. During the development process, we aimed to explore whether device activation in torque control (TC) mode would improve the function of the LAAD. The TC mode causes adjustment of the pump speed automatically during each cardiac cycle in order to maintain a specified torque. In this study, we tested four different TC settings (TC modes 0.9, 1.0, 1.25, and 1.5) using an in vitro mock circulatory loop. Mild, moderate, and severe diastolic heart failure (DHF) conditions, as well as normal heart condition, were simulated with the four TC modes. Also, we evaluated the LAAD in vivo with three calves. The LAAD was implanted at the mitral position with four TC settings (TC modes 0.9, 1.0, 1.1, 1.2). With LAAD support, the in vitro cardiac output and aortic pressure recovered to normal heart levels at TC 1.25 and 1.5 even under severe DHF conditions with little pump regurgitation. The TC mode tested in vivo with three calves, and it also showed favorable result without elevating the left ventricular end-diastolic pressure. These initial in vitro and in vivo results suggest that the TC mode could be potentially effective, and the LAAD could be a treatment option for HFpEF patients.
Collapse
Affiliation(s)
- Chihiro Miyagi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Barry D Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA. .,Electronics Core, Medical Device Solutions, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.
| | - Christine R Flick
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Anthony R Polakowski
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Takuma Miyamoto
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Randall C Starling
- Department of Cardiovascular Medicine, Miller Family Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA.,Kaufman Center for Heart Failure Treatment and Recovery, Cleveland Clinic, Cleveland, OH, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
4
|
Parra-Lucares A, Romero-Hernández E, Villa E, Weitz-Muñoz S, Vizcarra G, Reyes M, Vergara D, Bustamante S, Llancaqueo M, Toro L. New Opportunities in Heart Failure with Preserved Ejection Fraction: From Bench to Bedside… and Back. Biomedicines 2022; 11:70. [PMID: 36672578 PMCID: PMC9856156 DOI: 10.3390/biomedicines11010070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 12/07/2022] [Accepted: 12/13/2022] [Indexed: 12/29/2022] Open
Abstract
Heart failure with preserved ejection fraction (HFpEF) is a growing public health problem in nearly 50% of patients with heart failure. Therefore, research on new strategies for its diagnosis and management has become imperative in recent years. Few drugs have successfully improved clinical outcomes in this population. Therefore, numerous attempts are being made to find new pharmacological interventions that target the main mechanisms responsible for this disease. In recent years, pathological mechanisms such as cardiac fibrosis and inflammation, alterations in calcium handling, NO pathway disturbance, and neurohumoral or mechanic impairment have been evaluated as new pharmacological targets showing promising results in preliminary studies. This review aims to analyze the new strategies and mechanical devices, along with their initial results in pre-clinical and different phases of ongoing clinical trials for HFpEF patients. Understanding new mechanisms to generate interventions will allow us to create methods to prevent the adverse outcomes of this silent pandemic.
Collapse
Affiliation(s)
- Alfredo Parra-Lucares
- Critical Care Unit, Department of Medicine, Hospital Clínico Universidad de Chile, Santiago 8380420, Chile
- MD PhD Program, Faculty of Medicine, Universidad de Chile, Santiago 8380420, Chile
| | - Esteban Romero-Hernández
- MD PhD Program, Faculty of Medicine, Universidad de Chile, Santiago 8380420, Chile
- Division of Internal Medicine, Department of Medicine, Hospital Clínico Universidad de Chile, Santiago 8380420, Chile
| | - Eduardo Villa
- School of Medicine, Faculty of Medicine, Universidad de Chile, Santiago 8380420, Chile
| | - Sebastián Weitz-Muñoz
- Division of Internal Medicine, Department of Medicine, Hospital Clínico Universidad de Chile, Santiago 8380420, Chile
| | - Geovana Vizcarra
- Division of Internal Medicine, Department of Medicine, Hospital Clínico Universidad de Chile, Santiago 8380420, Chile
| | - Martín Reyes
- School of Medicine, Faculty of Medicine, Universidad de Chile, Santiago 8380420, Chile
| | - Diego Vergara
- School of Medicine, Faculty of Medicine, Universidad de Chile, Santiago 8380420, Chile
| | - Sergio Bustamante
- Coronary Care Unit, Cardiovascular Department, Hospital Clínico Universidad de Chile, Santiago 8380420, Chile
| | - Marcelo Llancaqueo
- Coronary Care Unit, Cardiovascular Department, Hospital Clínico Universidad de Chile, Santiago 8380420, Chile
| | - Luis Toro
- Division of Nephrology, Department of Medicine, Hospital Clínico Universidad de Chile, Santiago 8380420, Chile
- Centro de Investigación Clínica Avanzada, Hospital Clínico, Universidad de Chile, Santiago 8380420, Chile
| |
Collapse
|
5
|
Arduini M, Pham J, Marsden AL, Chen IY, Ennis DB, Dual SA. Framework for patient-specific simulation of hemodynamics in heart failure with counterpulsation support. Front Cardiovasc Med 2022; 9:895291. [PMID: 35979018 PMCID: PMC9376255 DOI: 10.3389/fcvm.2022.895291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Accepted: 07/13/2022] [Indexed: 11/17/2022] Open
Abstract
Despite being responsible for half of heart failure-related hospitalizations, heart failure with preserved ejection fraction (HFpEF) has limited evidence-based treatment options. Currently, a substantial clinical issue is that the disease etiology is very heterogenous with no patient-specific treatment options. Modeling can provide a framework for evaluating alternative treatment strategies. Counterpulsation strategies have the capacity to improve left ventricular diastolic filling by reducing systolic blood pressure and augmenting the diastolic pressure that drives coronary perfusion. Here, we propose a framework for testing the effectiveness of a soft robotic extra-aortic counterpulsation strategy using a patient-specific closed-loop hemodynamic lumped parameter model of a patient with HFpEF. The soft robotic device prototype was characterized experimentally in a physiologically pressurized (50–150 mmHg) soft silicone vessel and modeled as a combination of a pressure source and a capacitance. The patient-specific model was created using open-source software and validated against hemodynamics obtained by imaging of a patient (male, 87 years, HR = 60 bpm) with HFpEF. The impact of actuation timing on the flows and pressures as well as systolic function was analyzed. Good agreement between the patient-specific model and patient data was achieved with relative errors below 5% in all categories except for the diastolic aortic root pressure and the end systolic volume. The most effective reduction in systolic pressure compared to baseline (147 vs. 141 mmHg) was achieved when actuating 350 ms before systole. In this case, flow splits were preserved, and cardiac output was increased (5.17 vs. 5.34 L/min), resulting in increased blood flow to the coronaries (0.15 vs. 0.16 L/min). Both arterial elastance (0.77 vs. 0.74 mmHg/mL) and stroke work (11.8 vs. 10.6 kJ) were decreased compared to baseline, however left atrial pressure increased (11.2 vs. 11.5 mmHg). A higher actuation pressure is associated with higher systolic pressure reduction and slightly higher coronary flow. The soft robotic device prototype achieves reduced systolic pressure, reduced stroke work, slightly increased coronary perfusion, but increased left atrial pressures in HFpEF patients. In future work, the framework could include additional physiological mechanisms, a larger patient cohort with HFpEF, and testing against clinically used devices.
Collapse
Affiliation(s)
- Mattia Arduini
- Department of Radiology, Stanford University, Palo Alto, CA, United States
| | - Jonathan Pham
- Mechanical Engineering, Stanford University, Palo Alto, CA, United States
| | - Alison L. Marsden
- Department of Bioengineering, Stanford University, Palo Alto, CA, United States
- Department of Pediatrics, Stanford University, Palo Alto, CA, United States
| | - Ian Y. Chen
- Cardiovascular Institute, Stanford University, Palo Alto, CA, United States
- Division of Medicine (Cardiology), Veterans Affairs Health Care System, Palo Alto, CA, United States
| | - Daniel B. Ennis
- Department of Radiology, Stanford University, Palo Alto, CA, United States
- Cardiovascular Institute, Stanford University, Palo Alto, CA, United States
- Division of Radiology, Veterans Affairs Health Care System, Palo Alto, CA, United States
| | - Seraina A. Dual
- Department of Radiology, Stanford University, Palo Alto, CA, United States
- Cardiovascular Institute, Stanford University, Palo Alto, CA, United States
- *Correspondence: Seraina A. Dual
| |
Collapse
|
6
|
Comparison of device-based therapy options for heart failure with preserved ejection fraction: a simulation study. Sci Rep 2022; 12:5761. [PMID: 35388023 PMCID: PMC8987034 DOI: 10.1038/s41598-022-09637-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 03/25/2022] [Indexed: 12/29/2022] Open
Abstract
Successful therapy of heart failure with preserved ejection fraction (HFpEF) remains a major unmet clinical need. Device-based treatment approaches include the interatrial shunt device (IASD), conventional assist devices pumping blood from the left ventricle (LV-VAD) or the left atrium (LA-VAD) towards the aorta, and a valveless pulsatile assist device with a single cannula operating in co-pulsation with the native heart (CoPulse). Hemodynamics of two HFpEF subgroups during rest and exercise condition were translated into a lumped parameter model of the cardiovascular system. The numerical model was applied to assess the hemodynamic effect of each of the four device-based therapies. All four therapy options show a reduction in left atrial pressure during rest and exercise and in both subgroups (> 20%). IASDs concomitantly reduce cardiac output (CO) and shift the hemodynamic overload towards the pulmonary circulation. All three mechanical assist devices increase CO while reducing sympathetic activity. LV-VADs reduce end-systolic volume, indicating a high risk for suction events. The heterogeneity of the HFpEF population requires an individualized therapy approach based on the underlying hemodynamics. Whereas phenotypes with preserved CO may benefit most from an IASD device, HFpEF patients with reduced CO may be candidates for mechanical assist devices.
Collapse
|
7
|
Miyagi C, Fukamachi K, Kuban BD, Gao S, Miyamoto T, Flick CR, Polakowski AR, Horvath DJ, Starling RC, Karimov JH. Left Atrial Circulatory Assistance in Simulated Diastolic Heart Failure Model: First in Vitro and in Vivo. J Card Fail 2022; 28:789-798. [PMID: 35027316 PMCID: PMC9106897 DOI: 10.1016/j.cardfail.2021.11.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 10/21/2021] [Accepted: 11/22/2021] [Indexed: 01/10/2023]
Abstract
BACKGROUND We are developing a left atrial assist device (LAAD) that is implanted at the mitral position to treat diastolic heart failure (DHF) represented by heart failure with preserved ejection fraction. METHODS The LAAD was tested at 3 pump speeds on a pulsatile mock loop with a pneumatic pump that simulated DHF conditions by adjusting the diastolic drive. The LAAD was implanted in 6 calves, and the hemodynamics were assessed. In 3 cases, DHF conditions were induced by using a balloon inserted into the left ventricle, and in 2 cases, mitral valve replacement was also performed after the second aortic cross-clamp. RESULTS DHF conditions were successfully induced in the in vitro study. With LAAD support, cardiac output, aortic pressure and left atrial pressure recovered to normal values, whereas pulsatility was maintained for both in vivo and in vitro studies. Echocardiography showed no left ventricular outflow tract obstruction, and the LAAD was successfully replaced by a mechanical prosthetic valve. CONCLUSIONS These initial in vitro and in vivo results support our hypothesis that use of the LAAD increases cardiac output and aortic pressure and decreases left atrial pressure, while maintaining arterial pulsatility.
Collapse
Affiliation(s)
- Chihiro Miyagi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio.
| | - Barry D Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio; Electronics Core, Medical Device Solutions, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Shengquiang Gao
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Takuma Miyamoto
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Christine R Flick
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Anthony R Polakowski
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | | | - Randall C Starling
- Department of Cardiovascular Medicine, Heart,Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio; Kaufman Center for Heart Failure Treatment and Recovery, Cleveland Clinic, Cleveland, Ohio
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
8
|
Abstract
Heart failure with preserved ejection fraction (HFpEF) is a syndrome with an unfavorable prognosis, and the number of the patients continues to grow. Because there is no effective therapy established as a standard, including pharmacological treatments, a movement to develop and evaluate device-based therapies is an important emerging area in the treatment of HFpEF patients. Many devices have set their target to reduce the left atrial pressure or pulmonary capillary wedge pressure because they are strongly related to the symptoms and prognosis of HFpEF, but the methodology to achieve it varies based on the devices. In this review, we summarize and categorize these devices into the following: (1) interatrial shunt devices, (2) left ventricle expander, (3) electrical therapy, (4) left ventricular assist devices, and (5) mechanical circulatory support devices under development. Here, we describe the features and specifications of device-based therapies currently under development and those at more advanced stages of preclinical testing. Advantages and limitations of these technologies, with insights on their safety and feasibility for HFpEF patients, are described.
Collapse
|
9
|
Haberbusch M, De Luca D, Moscato F. Changes in Resting and Exercise Hemodynamics Early After Heart Transplantation: A Simulation Perspective. Front Physiol 2020; 11:579449. [PMID: 33240102 PMCID: PMC7677526 DOI: 10.3389/fphys.2020.579449] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 09/30/2020] [Indexed: 11/13/2022] Open
Abstract
Introduction: During heart transplantation (HTx), cardiac denervation is inevitable, thus typically resulting in chronic resting tachycardia and chronotropic incompetence with possible consequences in patient quality of life and clinical outcomes. To this date, knowledge of hemodynamic changes early after HTx is still incomplete. This study aims at providing a model-based description of the complex hemodynamic changes at rest and during exercise in HTx recipients (HTxRs). Materials and Methods: A numerical model of early HTxRs is developed that integrates intrinsic and autonomic heart rate (HR) control into a lumped-parameter cardiovascular system model. Intrinsic HR control is realized by a single-cell sinoatrial (SA) node model. Autonomic HR control is governed by aortic baroreflex and pulmonary stretch reflex and modulates SA node activity through neurotransmitter release. The model is tuned based on published clinical data of 15 studies. Simulations of rest and exercise are performed to study hemodynamic changes associated with HTxRs. Results: Simulations of HTxRs at rest predict a substantially increased HR [93.8 vs. 69.5 beats/min (bpm)] due to vagal denervation while maintaining normal cardiac output (CO) (5.2 vs. 5.6 L/min) through a reduction in stroke volume (SV) (55.4 vs. 82 mL). Simulations of exercise predict markedly reduced peak CO (13 vs. 19.8 L/min) primarily resulting from diminished peak HRs (133.9 vs. 169 bpm) and reduced ventricular contractility. Yet, the model results show that HTxRs can maintain normal CO for low- to medium-intensity exercise by increased SV augmentation through the Frank-Starling mechanism. Conclusion: Relevant hemodynamic changes occur after HTx. Simulations suggest that (1) increased resting HRs solely result from the absence of vagal tone; (2) chronotropic incompetence is the main limiting factor of exercise capacity whereby peripheral factors play a secondary role; and (3) despite the diminished exercise capacity, HTxRs can compensate chronotropic incompetence by a preload-mediated increase in SV augmentation and thus maintain normal CO in low- to medium-intensity exercise.
Collapse
Affiliation(s)
- Max Haberbusch
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria
| | - Daniela De Luca
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
- Department of Information Engineering, University of Pisa, Pisa, Italy
| | - Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria
- Austrian Cluster for Tissue Regeneration, Vienna, Austria
| |
Collapse
|
10
|
Escher A, Choi Y, Callaghan F, Thamsen B, Kertzscher U, Schweiger M, Hübler M, Granegger M. A Valveless Pulsatile Pump for Heart Failure with Preserved Ejection Fraction: Hemo- and Fluid Dynamic Feasibility. Ann Biomed Eng 2020; 48:1821-1836. [PMID: 32232694 PMCID: PMC7280352 DOI: 10.1007/s10439-020-02492-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 03/15/2020] [Indexed: 01/02/2023]
Abstract
Treatment of heart failure with preserved ejection fraction (HFpEF) remains a major unmet medical need. An implantable valveless pulsatile pump with a single cannula—the CoPulse pump—may provide beneficial hemodynamic support for select HFpEF patients when connected to the failing ventricle. We aimed to demonstrate hemodynamic efficacy and hemocompatible design feasibility for this novel assist device. The hemodynamic effect of the pump was investigated with an in vitro circulatory mock loop and an ex vivo isolated porcine heart model. The hydraulic design was optimized using computational fluid dynamics (CFD), and validated by 4D-flow magnetic resonance imaging (MRI). The pump reduced left atrial pressure (> 27%) and increased cardiac output (> 14%) in vitro. Ex vivo experiments revealed elevated total stroke volume at increased end-systolic volume during pump support. Asymmetric cannula positioning indicated superior washout, decreased stagnation (8.06 mm2 vs. 31.42 mm2), and marginal blood trauma potential with moderate shear stresses (< 24 Pa) in silico. Good agreement in flow velocities was evident among CFD and 4D-flow MRI data (r > 0.76). The CoPulse pump proved hemodynamically effective. Hemocompatibility metrics were comparable to those of a previously reported, typical pulsatile pump with two cannulae. The encouraging in vitro, ex vivo, and hemocompatibility results substantiate further development of the CoPulse pump.
Collapse
Affiliation(s)
- Andreas Escher
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland.,Biofluid Mechanics Laboratory, Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, Berlin, Germany.,Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, Zurich, Switzerland
| | - Young Choi
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Fraser Callaghan
- Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland.,Center for MR Research, University Children's Hospital Zurich, Zurich, Switzerland
| | - Bente Thamsen
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland.,Biofluid Mechanics Laboratory, Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, Berlin, Germany
| | - Ulrich Kertzscher
- Biofluid Mechanics Laboratory, Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, Berlin, Germany
| | - Martin Schweiger
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Michael Hübler
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Marcus Granegger
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland. .,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland. .,Biofluid Mechanics Laboratory, Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, Berlin, Germany.
| |
Collapse
|
11
|
Hemodynamic exercise responses with a continuous-flow left ventricular assist device: Comparison of patients' response and cardiorespiratory simulations. PLoS One 2020; 15:e0229688. [PMID: 32187193 PMCID: PMC7080259 DOI: 10.1371/journal.pone.0229688] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Accepted: 02/11/2020] [Indexed: 12/24/2022] Open
Abstract
Background Left ventricular assist devices (LVADs) are an established treatment for end stage heart failure patients. As LVADs do not currently respond to exercise demands, attention is also directed towards improvements in exercise capacity and resulting quality of life. The aim of this study was to explore hemodynamic responses observed during maximal exercise tests to infer underlying patient status and therefore investigate possible diagnostics from LVAD derived data and advance the development of physiologically adaptive LVAD controllers. Methods High resolution continuous LVAD flow waveforms were recorded from 14 LVAD patients and evaluated at rest and during maximum bicycle exercise tests (n = 24). Responses to exercise were analyzed in terms of an increase (↑) or decrease (↓) in minimum (QMIN), mean (QMEAN), maximum flow (QMAX) and flow pulsatility (QP2P). To interpret clinical data, a cardiorespiratory numerical simulator was used that reproduced patients’ hemodynamics at rest and exercise. Different cardiovascular scenarios including chronotropic and inotropic responses, peripheral vasodilation, and aortic valve pathologies were simulated systematically and compared to the patients’ responses. Results Different patients’ responses to exercise were observed. The most common response was a positive change of ΔQMIN↑ and ΔQP2P↑ from rest to exercise (70% of exercise tests). Two responses, which were never reported in patients so far, were distinguished by QMIN↑ and QP2P↓ (observed in 17%) and by QMIN↓ and QP2P↑ (observed in 13%). The simulations indicated that the QP2P↓ can result from a reduced left ventricular contractility and that the QMIN↓ can occur with a better left ventricular contractility and/or aortic insufficiency. Conclusion LVAD flow waveforms determine a patients’ hemodynamic “fingerprint” from rest to exercise. Different waveform responses to exercise, including previously unobserved ones, were reported. The simulations indicated the left ventricular contractility as a major determinant for the different responses, thus improving patient stratification to identify how patient groups would benefit from exercise-responsive LVAD control.
Collapse
|
12
|
Telyshev D, Petukhov D, Selishchev S. Numerical modeling of continuous-flow left ventricular assist device performance. Int J Artif Organs 2019; 42:611-620. [PMID: 31169054 DOI: 10.1177/0391398819852365] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Responses of five rotary blood pumps, namely HeartAssist 5, HeartMate II, HeartWare, Sputnik 1, and Sputnik 2, were extensively assessed in six test cases using a mathematical model of the cardiovascular system. Data for the rotary pumps were derived from pressure-flow curves reported in the literature. The test cases were chosen to attempt to cover most common clinical conditions, such as partial or full support or transitions between different levels of ventricular support. The investigated parameters are collected in a table and presented in figures, such as pressure-volume loops, H-Q curves, pump flow, and aortic pressure waveforms. HeartAssist, Sputnik 1, and Sputnik 2 pumps provide comparable level of aortic pressure, pump flow pulsatility PI(QP), and aortic pressure pulsatility PI(AoP) due to the similarity of pressure-flow characteristic curves of these pumps. HeartMate II provides a minimal backflow among other investigated rotary blood pumps due to the maximum pressure head at zero flow. HeartWare provides minimal pulsation of flow, which is confirmed by a flow range from -2 to 7 L/min in case 1. At the same time, the greatest degree of unloading was demonstrated by the HeartWare due to the flatness of the pressure-flow curve shape. The conclusions were made based on the obtained results, including the influence of pressure-flow curve shape on the pump performance and occurrences of adverse events, such as backflow or suction. For example, the increase of the pressure head at zero flow decreases the likelihood of backflow through the pump, and with it, increasing the flow under minimal pressure head increases the likelihood of suction.
Collapse
Affiliation(s)
- Dmitry Telyshev
- National Research University of Electronic Technology, Zelenograd, Russia.,Sechenov First Moscow State Medical University, Moscow, Russia
| | - Dmitry Petukhov
- National Research University of Electronic Technology, Zelenograd, Russia
| | - Sergey Selishchev
- National Research University of Electronic Technology, Zelenograd, Russia
| |
Collapse
|
13
|
Granegger M, Dave H, Knirsch W, Thamsen B, Schweiger M, Hübler M. A Valveless Pulsatile Pump for the Treatment of Heart Failure with Preserved Ejection Fraction: A Simulation Study. Cardiovasc Eng Technol 2018; 10:69-79. [PMID: 30536212 DOI: 10.1007/s13239-018-00398-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Accepted: 12/03/2018] [Indexed: 12/13/2022]
Abstract
PURPOSE Effective treatment of patients with terminal heart failure and preserved ejection fraction (HFpEF) is an unmet medical need. The aim of this study was to investigate a novel valveless pulsatile pump as a therapeutic option for the HFpEF population through comprehensive in silico investigations. METHODS The pump was simulated in a numerical model of the cardiovascular system of four HFpEF phenotypes and compared to a typical case of heart failure with reduced ejection fraction (HFrEF). The proposed pump, which was modeled as being directly connected to the left ventricle, features a single valveless inlet and outlet cannula and is driven in co-pulsation with the left ventricle. We collected hemodynamics for two different pump volumes (30 and 60 mL). RESULTS In all HFpEF conditions, the 30 mL pump improved the cardiac output by approximately 1 L/min, increased the mean arterial pressure by > 11% and lowered the mean left atrial pressure by > 30%. With the larger (60 mL) stroke volume, these hemodynamic improvements were more pronounced. In the HFrEF condition however, these effects were three times less in magnitude. CONCLUSIONS In this simulation study, the valveless pulsatile device improves hemodynamics in HFpEF patients by increasing the total stroke volume. The hemodynamic benefits are achieved with a small device volume comparable to implantable rotary blood pumps.
Collapse
Affiliation(s)
- Marcus Granegger
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland. .,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland.
| | - Hitendu Dave
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Walter Knirsch
- Pediatric Cardiology, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Bente Thamsen
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Martin Schweiger
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Michael Hübler
- Pediatric Cardiovascular Surgery, Department of Surgery, Pediatric Heart Center, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| |
Collapse
|
14
|
Wiegmann L, Thamsen B, de Zélicourt D, Granegger M, Boës S, Schmid Daners M, Meboldt M, Kurtcuoglu V. Fluid Dynamics in the HeartMate 3: Influence of the Artificial Pulse Feature and Residual Cardiac Pulsation. Artif Organs 2018; 43:363-376. [PMID: 30129977 DOI: 10.1111/aor.13346] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 07/22/2018] [Accepted: 08/15/2018] [Indexed: 12/17/2022]
Abstract
Ventricular assist devices (VADs), among which the HeartMate 3 (HM3) is the latest clinically approved representative, are often the therapy of choice for patients with end-stage heart failure. Despite advances in the prevention of pump thrombosis, rates of stroke and bleeding remain high. These complications are attributed to the flow field within the VAD, among other factors. One of the HM3's characteristic features is an artificial pulse that changes the rotor speed periodically by 4000 rpm, which is meant to reduce zones of recirculation and stasis. In this study, we investigated the effect of this speed modulation on the flow fields and stresses using high-resolution computational fluid dynamics. To this end, we compared Eulerian and Lagrangian features of the flow fields during constant pump operation, during operation with the artificial pulse feature, and with the effect of the residual native cardiac cycle. We observed good washout in all investigated situations, which may explain the low incidence rates of pump thrombosis. The artificial pulse had no additional benefit on scalar washout performance, but it induced rapid variations in the flow velocity and its gradients. This may be relevant for the removal of deposits in the pump. Overall, we found that viscous stresses in the HM3 were lower than in other current VADs. However, the artificial pulse substantially increased turbulence, and thereby also total stresses, which may contribute to clinically observed issues related to hemocompatibility.
Collapse
Affiliation(s)
- Lena Wiegmann
- The Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland
| | - Bente Thamsen
- Pediatric Cardiovascular Surgery, Pediatric Heart Center, Department of Surgery, University Children's Hospital Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Switzerland.,Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Diane de Zélicourt
- The Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland.,Children's Research Center, University Children's Hospital Zurich, Switzerland
| | - Marcus Granegger
- Pediatric Cardiovascular Surgery, Pediatric Heart Center, Department of Surgery, University Children's Hospital Zurich, Zurich, Switzerland
| | - Stefan Boës
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Marianne Schmid Daners
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Mirko Meboldt
- Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Vartan Kurtcuoglu
- The Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland.,National Center of Competence in Research, Kidney CH, Zurich, Switzerland.,Zurich Center for Integrative Human Physiology, University of Zurich, Zurich, Switzerland
| |
Collapse
|
15
|
Granegger M, Schweiger M, Schmid Daners M, Meboldt M, Hübler M. Cavopulmonary mechanical circulatory support in Fontan patients and the need for physiologic control: A computational study with a closed-loop exercise model. Int J Artif Organs 2018. [DOI: 10.1177/0391398818762359] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose: Rotary blood pumps are a promising treatment approach for patients with a total cavopulmonary connection and a failing cardiovascular system. The aim of this study was to investigate the hemodynamic effects of cavopulmonary support using a numerical model with closed-loop baroreflex and exercise mechanisms. Methods: A numerical model of the univentricular cardiovascular system was developed, mimicking the hemodynamics during rest and exercise. Rotary blood pumps with different hydraulic pump characteristics (flat vs steep pressure-flow relationships) were investigated in the cavopulmonary position. Furthermore, two support modes—a constant speed setting and a physiologically controlled speed—were examined. Results: Hemodynamics without rotary blood pumps were achieved with less than 10% deviation from reported values during rest and exercise. Rotary blood pumps at constant speed improve the hemodynamics at rest, however, they constitute a hydraulic resistance during light (steep characteristics) or moderate (flat characteristics) exercise. In contrast, physiologic control increases cardiac output (moderate exercise: 8.2 vs 7.4 L/min) and reduces sympathetic activation (heart rate at moderate exercise: 111 vs 123 bpm). Conclusion: In this simulation study, the necessity of an automatically controlled rotary blood pump in the cavopulmonary position was shown. A pump at constant speed might constitute an additional resistance to venous return during physical activity. Therefore, a physiologic control algorithm based on the pressure difference between the caval veins and the atrial pressure is proposed to improve hemodynamics, especially during physical activity.
Collapse
Affiliation(s)
- Marcus Granegger
- Pediatric Heart Center, University Children’s Hospital, University of Zurich, Zurich, Switzerland
| | - Martin Schweiger
- Pediatric Heart Center, University Children’s Hospital, University of Zurich, Zurich, Switzerland
| | - Marianne Schmid Daners
- pd
- z Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Mirko Meboldt
- pd
- z Product Development Group Zurich, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Michael Hübler
- Pediatric Heart Center, University Children’s Hospital, University of Zurich, Zurich, Switzerland
| |
Collapse
|
16
|
Pan Q, Zhou G, Wang R, Yu Y, Li F, Fang L, Yan J, Ning G. The degree of heart rate asymmetry is crucial for the validity of the deceleration and acceleration capacity indices of heart rate: A model-based study. Comput Biol Med 2016; 76:39-49. [PMID: 27392228 DOI: 10.1016/j.compbiomed.2016.06.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Revised: 05/24/2016] [Accepted: 06/20/2016] [Indexed: 11/20/2022]
Abstract
The deceleration capacity (DC) and acceleration capacity (AC) of heart rate are a pair of indices used for evaluating the autonomic nervous system (ANS). We assessed the role of heart rate asymmetry (HRA) in defining the relative performance of DC and AC using a mathematical model, which is able to generate a realistic RR interval (RRI) time series with controlled ANS states. The simulation produced a set of RRI series with random sympathetic and vagal activities. The multi-scale DCs and ACs were computed from the RRI series, and the correlation of DC and AC with the ANS functions was analyzed to evaluate the performance of the indices. In the model, the HRA level was modified by changing the inspiration/expiration (I/E) ratio to examine the influence of HRA on the performances of DC and AC. The results show that on the conventional scales (T=1, s=2), an HRA level above 50% results in a stronger association of DC with the ANS, compared with AC. On higher scales (T=4, s=6), there was no HRA and DC showed a similar performance to AC for all I/E ratios. The data suggest that the HRA level determines which of DC or AC is the optimal index for expressing ANS functions. Future clinical applications of DC and AC should be accompanied by an HRA analysis to provide a better index for assessing ANS.
Collapse
Affiliation(s)
- Qing Pan
- College of Information Engineering, Zhejiang University of Technology, 288 Liuhe Road, Hangzhou 310023, China
| | - Gongzhan Zhou
- College of Information Engineering, Zhejiang University of Technology, 288 Liuhe Road, Hangzhou 310023, China
| | - Ruofan Wang
- Department of Biomedical Engineering, Key Laboratory of Biomedical Engineering of Ministry of Education, Zhejiang University, 38 Zheda Road, Hangzhou 310027, China
| | - Yihua Yu
- Department of ICU, Zhejiang Hospital, 12 Lingyin Road, Hangzhou 310013, China
| | - Feng Li
- College of Information Engineering, Zhejiang University of Technology, 288 Liuhe Road, Hangzhou 310023, China
| | - Luping Fang
- College of Information Engineering, Zhejiang University of Technology, 288 Liuhe Road, Hangzhou 310023, China
| | - Jing Yan
- Department of ICU, Zhejiang Hospital, 12 Lingyin Road, Hangzhou 310013, China.
| | - Gangmin Ning
- Department of Biomedical Engineering, Key Laboratory of Biomedical Engineering of Ministry of Education, Zhejiang University, 38 Zheda Road, Hangzhou 310027, China.
| |
Collapse
|
17
|
Nguyen PH, Tuzun E, Quick CM. Aortic pulse pressure homeostasis emerges from physiological adaptation of systemic arteries to local mechanical stresses. Am J Physiol Regul Integr Comp Physiol 2016; 311:R522-31. [PMID: 27306830 DOI: 10.1152/ajpregu.00402.2015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2015] [Accepted: 06/13/2016] [Indexed: 11/22/2022]
Abstract
Aortic pulse pressure arises from the interaction of the heart, the systemic arterial system, and peripheral microcirculations. The complex interaction between hemodynamics and arterial remodeling precludes the ability to experimentally ascribe changes in aortic pulse pressure to particular adaptive responses. Therefore, the purpose of the present work was to use a human systemic arterial system model to test the hypothesis that pulse pressure homeostasis can emerge from physiological adaptation of systemic arteries to local mechanical stresses. First, we assumed a systemic arterial system that had a realistic topology consisting of 121 arterial segments. Then the relationships of pulsatile blood pressures and flows in arterial segments were characterized by standard pulse transmission equations. Finally, each arterial segment was assumed to remodel to local stresses following three simple rules: 1) increases in endothelial shear stress increases radius, 2) increases in wall circumferential stress increases wall thickness, and 3) increases in wall circumferential stress decreases wall stiffness. Simulation of adaptation by iteratively calculating pulsatile hemodynamics, mechanical stresses, and vascular remodeling led to a general behavior in response to mechanical perturbations: initial increases in pulse pressure led to increased arterial compliances, and decreases in pulse pressure led to decreased compliances. Consequently, vascular adaptation returned pulse pressures back toward baseline conditions. This behavior manifested when modeling physiological adaptive responses to changes in cardiac output, changes in peripheral resistances, and changes in local arterial radii. The present work, thus, revealed that pulse pressure homeostasis emerges from physiological adaptation of systemic arteries to local mechanical stresses.
Collapse
Affiliation(s)
- Phuc H Nguyen
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; and
| | - Egemen Tuzun
- Texas A&M Institute for Preclinical Studies, College Station, Texas
| | - Christopher M Quick
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; and
| |
Collapse
|
18
|
Malchesky PS. Dr. Francesco Moscato appointed as co-editor representing the International Society for Rotary Blood Pumps. Artif Organs 2015; 39:199-200. [PMID: 25788209 DOI: 10.1111/aor.12492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
19
|
Karmonik C, Partovi S, Loebe M, Schmack B, Weymann A, Lumsden AB, Karck M, Ruhparwar A. Computational fluid dynamics in patients with continuous-flow left ventricular assist device support show hemodynamic alterations in the ascending aorta. J Thorac Cardiovasc Surg 2014; 147:1326-1333.e1. [DOI: 10.1016/j.jtcvs.2013.09.069] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2013] [Revised: 07/30/2013] [Accepted: 09/30/2013] [Indexed: 01/24/2023]
|