Moore GW, Platton S, Yartey N, Foxton E, White D, MacDonald SG. Taipan snake venom time has high sensitivity for lupus anticoagulants in non-anticoagulated, triple positive antiphospholipid syndrome patients.
Int J Lab Hematol 2024;
46:538-545. [PMID:
38303489 DOI:
10.1111/ijlh.14240]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 01/05/2024] [Indexed: 02/03/2024]
Abstract
INTRODUCTION
Dilute Russell's viper venom time (dRVVT) and activated partial thromboplastin time (APTT) are the mainstay assays in lupus anticoagulant (LA) detection yet they have limitations, particularly in relation to interferences and specificity. The recently validated Taipan snake venom time (TSVT) screening with ecarin time (ET) confirmatory assays overcome many of those limitations due to the innate specificity engendered from direct prothrombin activation, and insensitivity to the effects of vitamin K antagonists (VKA). The present study aimed to further evidence diagnostic utility of TSVT/ET by performing them in samples from 116 nonanticoagulated patients with established triple-positive antiphospholipid syndrome (APS).
METHODS
Samples were identified in three expert centres who performed dRVVT, APTT and solid phase antiphospholipid antibody assays with reagents from a variety of manufacturers. All samples additionally received TSVT/ET analysis using standardised reagents.
RESULTS
Ninety seven of 116 (83.6%) were dRVVT- and APTT-positive, 85/97 (87.6%) of which were TSVT/ET-positive, 9/116 (7.8%) were dRVVT-positive only, 6 of which were TSVT/ET-positive, and 10/116 (8.6%) were APTT-positive only, 5 of which were TSVT/ET-positive. 96/116 TSVT/ET-positivity returned a high sensitivity for LA of 82.8%. Low coefficients of determination revealed weak relationships between LA potency and anticardiolipin and anti-β2-glycoprotein I antibody titres for all three LA assays.
CONCLUSIONS
TSVT/ET has high sensitivity for the clinically significant LA found in triple positive APS patients. TSVT/ET can establish multiple LA assay positivity in nonanticoagulated patients negative for one of dRVVT or APTT, and is the only assay pairing insensitive to VKAs, the recommended anticoagulation for APS.
Collapse