1
|
Robinson BP, Nanni GM. Utilizing fractional lasers and tirbanibulin ointment to treat squamous and basal cell carcinomas. Arch Dermatol Res 2024; 316:683. [PMID: 39400600 PMCID: PMC11473590 DOI: 10.1007/s00403-024-03423-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2024] [Revised: 08/19/2024] [Accepted: 09/30/2024] [Indexed: 10/15/2024]
Abstract
Keratinocyte carcinoma is the most common form of cancer in the United States. Often treated by surgical excision, electrodessication and curettage, or Mohs surgery, treatment can frequently leave patients with a scar and can be time consuming and inconvenient for both patients and healthcare providers. Utilizing non-ablative fractional laser therapy followed by tirbanibulin ointment, we treated 30 basal and/or squamous cell carcinomas on 23 patients over the age of 50 with varying skin types. Multiple areas of the face and body, and carcinomas at differing stages, were treated. We maximized the depth of penetration of the fractional laser by using bulk heating methods while simultaneously optimizing cosmetic results. This is an ongoing study as we continue to track the progress of our participants. Thus far, no clinical or histological recurrence of carcinoma has been found in any of the treated sites.
Collapse
|
2
|
Multilayer In Vitro Human Skin Tissue Platforms for Quantitative Burn Injury Investigation. Bioengineering (Basel) 2023; 10:bioengineering10020265. [PMID: 36829759 PMCID: PMC9952576 DOI: 10.3390/bioengineering10020265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 02/01/2023] [Accepted: 02/06/2023] [Indexed: 02/19/2023] Open
Abstract
This study presents a multilayer in vitro human skin platform to quantitatively relate predicted spatial time-temperature history with measured tissue injury response. This information is needed to elucidate high-temperature, short-duration burn injury kinetics and enables determination of relevant input parameters for computational models to facilitate treatment planning. Multilayer in vitro skin platforms were constructed using human dermal keratinocytes and fibroblasts embedded in collagen I hydrogels. After three seconds of contact with a 50-100 °C burn tip, ablation, cell death, apoptosis, and HSP70 expression were spatially measured using immunofluorescence confocal microscopy. Finite element modeling was performed using the measured thermal characteristics of skin platforms to determine the temperature distribution within platforms over time. The process coefficients for the Arrhenius thermal injury model describing tissue ablation and cell death were determined such that the predictions calculated from the time-temperature histories fit the experimental burn results. The activation energy for thermal collagen ablation and cell death was found to be significantly lower for short-duration, high-temperature burns than those found for long-duration, low-temperature burns. Analysis of results suggests that different injury mechanisms dominate at higher temperatures, necessitating burn research in the temperature ranges of interest and demonstrating the practicality of the proposed skin platform for this purpose.
Collapse
|
3
|
Tarle M, Zubović A, Kos B, Raguž M, Lukšić I. Retrospective Longitudinal Study on Changes in Atmospheric Pressure as a Predisposing Factor for Odontogenic Abscess Formation. Dent J (Basel) 2023; 11:42. [PMID: 36826187 PMCID: PMC9955754 DOI: 10.3390/dj11020042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 02/05/2023] [Accepted: 02/06/2023] [Indexed: 02/11/2023] Open
Abstract
In our retrospective longitudinal study based on the data from 292 patients, we wanted to investigate whether there was an association between weather conditions and the occurrence of odontogenic abscesses (OA) requiring hospitalization. In the adult group (249 patients), the incidence of severe OA was highest in winter (32.9%) during January (11.6%), with the most common localizations being the perimandibular (35.7%) and submandibular (23.3%) regions. We found that changes in mean daily atmospheric pressure five days before hospitalization showed a positive association with the occurrence of OA, especially pressure variations greater than 12 hPa. Atmospheric pressure changes two and five days before hospitalization were also found to be moderate predictors of complications during treatment. Antibiogram analysis revealed resistance of streptococci to clindamycin in 26.3%. In the pediatric group, OA were also most frequent in winter (30.2%), and the perimandibular region (37.2%) and the canine fossa (20.9%) were the most frequent abscess localizations, while an association with meteorological parameters was not demonstrated. Clinical experience teaches us that weather change influences the occurrence of severe OA requiring hospitalization, which we confirmed in this research. To our knowledge, our study is the first to provide a threshold and precise time frame for atmospheric pressure changes.
Collapse
Affiliation(s)
- Marko Tarle
- Department of Maxillofacial Surgery, Dubrava University Hospital, Gojko Šušak Avenue 6, 10000 Zagreb, Croatia
- School of Dental Medicine, University of Zagreb, Gundulićeva 5, 10000 Zagreb, Croatia
| | - Arijan Zubović
- Department of Maxillofacial Surgery, Clinical Hospital Center Rijeka, Krešimirova 42, 51000 Rijeka, Croatia
- The Faculty of Medicine, University of Rijeka, Braće Branchetta 20/1, 51000 Rijeka, Croatia
| | - Boris Kos
- Department of Maxillofacial Surgery, Dubrava University Hospital, Gojko Šušak Avenue 6, 10000 Zagreb, Croatia
| | - Marina Raguž
- Department of Neurosurgery, Dubrava University Hospital, Gojko Šušak Avenue 6, 10000 Zagreb, Croatia
- School of Medicine, Catholic University of Croatia, Ilica 242, 10000 Zagreb, Croatia
| | - Ivica Lukšić
- Department of Maxillofacial Surgery, Dubrava University Hospital, Gojko Šušak Avenue 6, 10000 Zagreb, Croatia
- School of Medicine, University of Zagreb, Šalata 3, 10000 Zagreb, Croatia
| |
Collapse
|
4
|
Wohlrab J, Mentel T, Eichner A. Efficiency of cutaneous heat diffusion after local hyperthermia for the treatment of itch. Skin Res Technol 2023; 29:e13277. [PMID: 36823504 PMCID: PMC10155804 DOI: 10.1111/srt.13277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 12/30/2022] [Indexed: 02/05/2023]
Abstract
BACKGROUND Today, itching is understood as an independent sensory perception, which is based on a complex etiology of a disturbed neuronal activity and leads to clinical symptoms. The primary afferents (pruriceptors) have functional overlaps with afferents of thermoregulation (thermoceptors). Thus, an antipruritic effect can be caused by antagonizing heat-sensitive receptors of the skin. The ion channel TRP-subfamily V member 1 (TRPV1) is of particular importance in this context. Repeated heat application can induce irreversible inactivation by unfolding of the protein, causing a persistent functional deficit and thus clinically and therapeutically reducing itch sensation. MATERIAL AND METHODS To demonstrate relevant heat diffusion after local application of heat (45°C to 52°C for 3 and 5 seconds) by a technical medical device, the temperature profile for the relevant skin layer was recorded synchronously on ex vivo human skin using an infrared microscope. RESULTS The results showed that the necessary activation temperature for TRPV1 of (≥43°C) in the upper relevant skin layers was safely reached after 3 and 5 seconds of application time. There were no indications of undesirable thermal effects. CONCLUSION The test results show that the objectified performance of the investigated medical device can be expected to provide the necessary temperature input for the activation of heat-sensitive receptors in the skin. Clinical studies are necessary to prove therapeutic efficacy in the indication pruritus.
Collapse
Affiliation(s)
- Johannes Wohlrab
- Department of Dermatology and VenereologyMartin Luther University Halle‐WittenbergHalle (Saale)Germany
- Institute of applied DermatopharmacyMartin Luther University Halle‐WittenbergHalle (Saale)Germany
| | | | - Adina Eichner
- Institute of applied DermatopharmacyMartin Luther University Halle‐WittenbergHalle (Saale)Germany
| |
Collapse
|
5
|
Ren Y, Yan Y, Qi H. Photothermal conversion and transfer in photothermal therapy: From macroscale to nanoscale. Adv Colloid Interface Sci 2022; 308:102753. [PMID: 36007283 DOI: 10.1016/j.cis.2022.102753] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 08/08/2022] [Accepted: 08/10/2022] [Indexed: 12/17/2022]
Abstract
Photothermal therapy (PTT) is a promising alternative therapy for benign or even malignant tumors. To improve the selective heating of tumor cells, target-specific photothermal conversion agents are often included, especially nanoparticles. Meanwhile, some indirect methods by manipulating the radiation and heat delivery are also adopted. Therefore, to gain a clear understanding of the mechanism, and to improve the controllability of PTT, a few issues need to be clarified, including bioheat and radiation transfer, localized and collective heating of nanoparticles, etc. In this review, we provide an introduction to the typical bioheat transfer and radiation transfer models along with the dynamic thermophysical properties of biological tissue. On this basis, we reviewed the most recent advances in the temperature control methods in PTT from macroscale to nanoscale. Most importantly, a comprehensive introduction of the localized and collective heating effects of nanoparticle clusters is provided to give a clear insight into the mechanism for PPT from the microscale and nanoscale point of view.
Collapse
Affiliation(s)
- Yatao Ren
- Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom; School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, PR China
| | - Yuying Yan
- Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.
| | - Hong Qi
- School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, PR China.
| |
Collapse
|
6
|
MORTAZAVI SARE, MOKHTARI-DIZAJI MANIJHE. EXTRACTION OF PRESSURE AND TEMPERATURE DISTRIBUTION OF HIGH INTENSITY FOCUSED ULTRASOUND CONSIDERING NONLINEAR PROPAGATION. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422500099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The aim of this study is the extraction of acoustic pressure distribution in the target tissue layers based on the nonlinear behavior of waves. The nonlinear behavior effect of high intensity focused ultrasound (HIFU) on the temperature distribution of the tissue was extracted and compared with the linear behavior. The acoustic pressure field was calculated using the Westervelt equation and was coupled with Pennes thermal transfer equation. The simulations were performed for three layers of skin, fat and muscle using Comsol software. The disagreement between two linear and nonlinear models was analyzed with Kolmogorov–Smirnov test. The pressure and temperature distributions were calculated in nonlinear model by changing the acoustical parameters of the transducer including intensity, effective radiation area, focal length and sonication time. Model results were validated with experimental results with 98% correlation coefficient ([Formula: see text]). There is no significant difference between the pressure amplitude and temperature distribution in linear and nonlinear models at low intensity ([Formula: see text]), but with increasing intensity to 10[Formula: see text]W/cm2, in nonlinear model, maximum pressure and maximum temperature increased 40% and 20% compared with linear model. For input intensities of 1.5, 2, 8 and 10[Formula: see text]W/cm2, the maximum pressure (at focal point) increased 10%, 12%, 22%, 40% and maximum temperature increased 1%, 2%, 12%, 20% in nonlinear model compared to linear model. At 0.8[Formula: see text]cm2 and 1.5[Formula: see text]cm2 effective radiation area, the maximum acoustic pressure and temperature in nonlinear model increased from 12[Formula: see text]MPa to 30[Formula: see text]MPa and 43∘C to 79∘C, respectively. By decreasing the focal lengths from 10[Formula: see text]mm to 7.5[Formula: see text]mm, the maximum temperature increased from 45∘C to 87∘C. It is concluded a change in the input parameters of the transducer; it can be very effective in treating. The results emphasize the effects of nonlinear propagation and acoustical radiation parameters to improve the HIFU treatment.
Collapse
Affiliation(s)
- SARE MORTAZAVI
- Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - MANIJHE MOKHTARI-DIZAJI
- Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| |
Collapse
|
7
|
Bianchi L, Cavarzan F, Ciampitti L, Cremonesi M, Grilli F, Saccomandi P. Thermophysical and mechanical properties of biological tissues as a function of temperature: a systematic literature review. Int J Hyperthermia 2022; 39:297-340. [DOI: 10.1080/02656736.2022.2028908] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Affiliation(s)
- Leonardo Bianchi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Fabiana Cavarzan
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Lucia Ciampitti
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Matteo Cremonesi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Francesca Grilli
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| | - Paola Saccomandi
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
8
|
Malekmohamadi MH, Ahmadikia H, Mosharaf-Dehkordi M. The effect of heat flux distribution and internal heat generation on the thermal damage in multilayer tissue in thermotherapy. J Therm Biol 2021; 99:102920. [PMID: 34420601 DOI: 10.1016/j.jtherbio.2021.102920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 03/23/2021] [Accepted: 03/27/2021] [Indexed: 10/21/2022]
Abstract
Proper analysis of the temperature distribution during heat therapy in the target tissue and around it will prevent damage to other adjacent healthy cells. In this study, the exact solution of steady and unsteady of the hyperbolic bioheat equations is performed for multilayer skin with tumor at different heat fluxes on its surface and the generation of internal heat in the tumor. By determining the temperature distribution in three modes of constant heat flux, parabolic heat flux and internal heat generation in tumor tissue, the amount of burn in all three modes is evaluated. The results indicated that the Fourier or non-Fourier behavior of tissue has no role in the rate of burns in thermotherapy processes. At equal powers applied to the tissue, the internal heat generation in the tumor, constant flux and parabolic flux on the skin surface have the most uniform and most non-uniform temperature distribution, respectively and cause the least and the most thermal damage in the tissue.
Collapse
Affiliation(s)
| | - Hossein Ahmadikia
- Department of Mechanical Engineering, University of Isfahan, Isfahan, Iran.
| | | |
Collapse
|
9
|
Singh S, Melnik R. Domain Heterogeneity in Radiofrequency Therapies for Pain Relief: A Computational Study with Coupled Models. Bioengineering (Basel) 2020; 7:E35. [PMID: 32272567 PMCID: PMC7355452 DOI: 10.3390/bioengineering7020035] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Revised: 03/25/2020] [Accepted: 04/02/2020] [Indexed: 12/11/2022] Open
Abstract
The objective of the current research work is to study the differences between the predicted ablation volume in homogeneous and heterogeneous models of typical radiofrequency (RF) procedures for pain relief. A three-dimensional computational domain comprising of the realistic anatomy of the target tissue was considered in the present study. A comparative analysis was conducted for three different scenarios: (a) a completely homogeneous domain comprising of only muscle tissue, (b) a heterogeneous domain comprising of nerve and muscle tissues, and (c) a heterogeneous domain comprising of bone, nerve and muscle tissues. Finite-element-based simulations were performed to compute the temperature and electrical field distribution during conventional RF procedures for treating pain, and exemplified here for the continuous case. The predicted results reveal that the consideration of heterogeneity within the computational domain results in distorted electric field distribution and leads to a significant reduction in the attained ablation volume during the continuous RF application for pain relief. The findings of this study could provide first-hand quantitative information to clinical practitioners about the impact of such heterogeneities on the efficacy of RF procedures, thereby assisting them in developing standardized optimal protocols for different cases of interest.
Collapse
Affiliation(s)
- Sundeep Singh
- MS2Discovery Interdisciplinary Research Institute, Wilfrid Laurier University, 75 University Avenue West, Waterloo, ON N2L 3C5, Canada;
| | - Roderick Melnik
- MS2Discovery Interdisciplinary Research Institute, Wilfrid Laurier University, 75 University Avenue West, Waterloo, ON N2L 3C5, Canada;
- BCAM—Basque Center for Applied Mathematics, Alameda de Mazarredo 14, E-48009 Bilbao, Spain
| |
Collapse
|
10
|
Singh S, Melnik R. Thermal ablation of biological tissues in disease treatment: A review of computational models and future directions. Electromagn Biol Med 2020; 39:49-88. [PMID: 32233691 DOI: 10.1080/15368378.2020.1741383] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Percutaneous thermal ablation has proven to be an effective modality for treating both benign and malignant tumours in various tissues. Among these modalities, radiofrequency ablation (RFA) is the most promising and widely adopted approach that has been extensively studied in the past decades. Microwave ablation (MWA) is a newly emerging modality that is gaining rapid momentum due to its capability of inducing rapid heating and attaining larger ablation volumes, and its lesser susceptibility to the heat sink effects as compared to RFA. Although the goal of both these therapies is to attain cell death in the target tissue by virtue of heating above 50°C, their underlying mechanism of action and principles greatly differs. Computational modelling is a powerful tool for studying the effect of electromagnetic interactions within the biological tissues and predicting the treatment outcomes during thermal ablative therapies. Such a priori estimation can assist the clinical practitioners during treatment planning with the goal of attaining successful tumour destruction and preservation of the surrounding healthy tissue and critical structures. This review provides current state-of-the-art developments and associated challenges in the computational modelling of thermal ablative techniques, viz., RFA and MWA, as well as touch upon several promising avenues in the modelling of laser ablation, nanoparticles assisted magnetic hyperthermia and non-invasive RFA. The application of RFA in pain relief has been extensively reviewed from modelling point of view. Additionally, future directions have also been provided to improve these models for their successful translation and integration into the hospital work flow.
Collapse
Affiliation(s)
- Sundeep Singh
- MS2Discovery Interdisciplinary Research Institute, Wilfrid Laurier University, Waterloo, Ontario, Canada
| | - Roderick Melnik
- MS2Discovery Interdisciplinary Research Institute, Wilfrid Laurier University, Waterloo, Ontario, Canada.,BCAM - Basque Center for Applied Mathematics, Bilbao, Spain
| |
Collapse
|
11
|
Fang Z, Moser MAJ, Zhang EM, Zhang W, Zhang B. A Novel Method to Increase Tumor Ablation Zones With RFA by Injecting the Cationic Polymer Solution to Tissues: In Vivo and Computational Studies. IEEE Trans Biomed Eng 2019; 67:1787-1796. [PMID: 31634120 DOI: 10.1109/tbme.2019.2947292] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE This study aims to examine, for the first time, the introduction of cationic polymer solutions to improve radiofrequency ablation (RFA) in terms of a potentially enlarged ablation zone. METHODS By using in vivo and computational RFA studies, two cationic polymers, Chitooligosaccharides (COS) and carboxymethyl chitosan (CMC), diluted in deionized water, were injected into tissues separately surrounding the RF bipolar electrode prior to power application. A total of 9 rabbits were used to 1) measure the increase in electrical conductivity of tissues injected with the cationic polymer solutions, and 2) explore the enhancement of the ablation performance in RFA trials. A computer model of RFA comprising a model of the solution diffusion with an RF thermal ablation model was also built, validated by the in vivo experiment, to quantitatively study the effect of cationic polymer solutions on ablation performances. RESULTS Compared to the control group, the electrical conductivity of rabbit liver tissues was increased by 42.20% (0.282 ± 0.006 vs. 0.401 ± 0.048 S/m, P = 0.001) and 43.97% (0.282 ± 0.006 vs. 0.406 ± 0.042 S/m, P = 0.001) by injecting the COS and CMC solution at the concentration of 100 mg/mL into the tissues, denoted COSDW100 and CMCDW100, respectively. Consequently, the in vivo experiments show that the ablation zone was enlarged by 95% (47.6 ± 6.3 vs. 92.6 ± 11.5 mm2, P < 0.001) and 87% (47.6± 6.3 vs. 88.8 ± 9.6 mm2, P < 0.001) by COSDW100 and CMCDW100, respectively. The computer simulation shows that the ablation zone was enlarged by 71% (51.9 vs. 88.7 mm2) and 63% (51.9 vs. 84.7 mm2) by COSDW100 and CMCDW100, respectively. CONCLUSION The injection of the cationic solution can greatly improve the performance of RFA treatment in terms of enlarging the ablation zone, which is due to the increase in the electrical conductivity of liver tissues surrounding the RF electrode. SIGNIFICANCE This study contributes to the improvement of RFA in the treatment of large tumors.
Collapse
|
12
|
Matsumoto K, Kimura SI, Itai S, Kondo H, Iwao Y. In vivo temperature-sensitive drug release system trigged by cooling using low-melting-point microcrystalline wax. J Control Release 2019; 303:281-288. [PMID: 31026549 DOI: 10.1016/j.jconrel.2019.04.029] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Revised: 04/19/2019] [Accepted: 04/20/2019] [Indexed: 10/27/2022]
Abstract
Temperature-sensitive formulations are attractive controlled-release formulations, which release an incorporated drug by changes in body temperature induced by external temperature stimulation. Recently, it has been reported that wax matrix (WM) particles composed of a low-melting-point microcrystalline wax (MCW) released only a small amount of the drug at 37 °C, whereas faster drug release occurred at 25 °C. In this study, temperature-sensitive formulations composed of low-melting-point MCW that release drugs triggered by cooling, rather than heating, were developed. In an in vitro dissolution test in which the test medium was repeatedly cooled from 37 to 25 °C, control of the promotion and suppression of drug release was achieved. The drug concentration in the plasma of rats administered the particles was significantly increased by cooling compared with non-cooling, indicating that the drug release from the particles was promoted by cooling both in vitro and in vivo. Therefore, particles composed of low-melting-point MCW should be useful for the development of cooling-triggered, temperature-sensitive formulations.
Collapse
Affiliation(s)
- Kohei Matsumoto
- Department of Pharmaceutical Engineering and Drug Delivery Science, School of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Suruga-ku, Shizuoka 422-8526, Japan
| | - Shin-Ichiro Kimura
- Department of Pharmaceutical Engineering and Drug Delivery Science, School of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Suruga-ku, Shizuoka 422-8526, Japan
| | - Shigeru Itai
- Department of Pharmaceutical Engineering and Drug Delivery Science, School of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Suruga-ku, Shizuoka 422-8526, Japan
| | - Hiromu Kondo
- Department of Pharmaceutical Engineering and Drug Delivery Science, School of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Suruga-ku, Shizuoka 422-8526, Japan
| | - Yasunori Iwao
- Department of Pharmaceutical Engineering and Drug Delivery Science, School of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Suruga-ku, Shizuoka 422-8526, Japan.
| |
Collapse
|
13
|
Kumar R, Vashishth AK, Ghangas S. Variable thermal conductivity approach for bioheat transfer during thermal ablation. ARAB JOURNAL OF BASIC AND APPLIED SCIENCES 2019. [DOI: 10.1080/25765299.2019.1566982] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Affiliation(s)
- Rajneesh Kumar
- Department of Mathematics, Kurukshetra University, Haryana, India
| | | | - Suniti Ghangas
- Department of Mathematics, Kurukshetra University, Haryana, India
| |
Collapse
|
14
|
Paul A, Paul A. Computational study of photo-thermal ablation of large blood vessel embedded tumor using localized injection of gold nanoshells. J Therm Biol 2018; 78:329-342. [DOI: 10.1016/j.jtherbio.2018.10.021] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 10/21/2018] [Accepted: 10/27/2018] [Indexed: 10/27/2022]
|
15
|
Hong X, Lin J, Liu Y, Xu W. Active Thermal Sensing for Bonding Structure Damage Detection of Hidden Frame Glass Curtain Wall. SENSORS (BASEL, SWITZERLAND) 2018; 18:E3594. [PMID: 30360503 PMCID: PMC6263633 DOI: 10.3390/s18113594] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 10/13/2018] [Accepted: 10/14/2018] [Indexed: 11/16/2022]
Abstract
Adhesive bonded structure damage of hidden frame glass curtain wall will cause falling glass, which threatens the security of people and property. Therefore, the damage detection of the adhesive bonded structure of glass curtain wall has great significance. In this paper, active thermal sensing technology for bonding structure damage detection was introduced. Firstly, the thermal wave propagation of bonded structure was analyzed. Second, the simulated annealing algorithm and TracePro simulation were utilized to design the heat source. Thirdly, the platform of active thermal sensing was built, and experiments were conducted. Finally, image fusion enhancement of Laplacian pyramid was utilized to the enhancement process of thermal images. The simulation results showed that the irradiance of the cross-optimization was more uniform, and the uniformity was 17.50% higher than the original design value. The experiments results showed that defects of different sizes and depths can be distinguished. The gray differences of the damages on the depth of 0 mm and 4 mm were 0.025 and 0.045, respectively. The thermal wave testing can detect damage intuitively and rapidly, which is significant for the future research of unmanned detection of bonding structure damage of hidden frame glass curtain wall.
Collapse
Affiliation(s)
- Xiaobin Hong
- School of Mechanical & Automotive Engineering, South China University of Technology, Guangzhou 510641, China.
| | - Jinfan Lin
- School of Mechanical & Automotive Engineering, South China University of Technology, Guangzhou 510641, China.
| | - Yuan Liu
- School of Mechanical & Automotive Engineering, South China University of Technology, Guangzhou 510641, China.
| | - Weiying Xu
- School of Mechanical & Automotive Engineering, South China University of Technology, Guangzhou 510641, China.
| |
Collapse
|
16
|
Mesicek J, Kuca K. Summary of numerical analyses for therapeutic uses of laser-activated gold nanoparticles. Int J Hyperthermia 2018; 34:1255-1264. [DOI: 10.1080/02656736.2018.1440016] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Affiliation(s)
- Jakub Mesicek
- Faculty of Informatics and Management, University of Hradec Kralove, Hradec Kralove, Czech Republic
| | - Kamil Kuca
- Faculty of Informatics and Management, University of Hradec Kralove, Hradec Kralove, Czech Republic
- Biomedical Research Centre, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic
| |
Collapse
|
17
|
Analytical expressions for estimating endurance time and glove thermal resistance related to human finger in cold conditions. J Therm Biol 2017; 69:334-340. [PMID: 29037403 DOI: 10.1016/j.jtherbio.2017.09.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2017] [Revised: 09/18/2017] [Accepted: 09/19/2017] [Indexed: 11/22/2022]
Abstract
Frostbite is considered the severest form of cold injury and can lead to necrosis and loss of peripheral appendages. Therefore, prediction of endurance time of limb's tissue in cold condition is not only necessary but also crucial to estimate cold injury intensity and to choose appropriate clothing. According to the previous work which applied a 3-D thermal model for human finger to analyze cold stress, in this study, an expression is presented for endurance time in cold conditions to prevent cold injury. A formula is also recommended to select a proper glove with specific thermal resistance based on the ambient situation and cold exposure time. By employing linear extrapolation and real physical conditions, the proposed formulas were drawn out from numerical simulation. Analytical results show good agreement with numerical data. The used numerical data had been also validated with experimental data existed in the literature. Furthermore, the effect of different parameters such as glove thermal resistance and ambient temperature is investigated analytically.
Collapse
|
18
|
Fallahi A, Reza Salimpour M, Shirani E. A 3D thermal model to analyze the temperature changes of digits during cold stress and predict the danger of frostbite in human fingers. J Therm Biol 2017; 65:153-160. [PMID: 28343569 DOI: 10.1016/j.jtherbio.2017.03.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Accepted: 03/03/2017] [Indexed: 11/28/2022]
Abstract
The existing computational models of frostbite injury are limited to one and two dimensional schemes. In this study, a coupled thermo-fluid model is applied to simulate a finger exposed to cold weather. The spatial variability of finger-tip temperature is compared to experimental ones to validate the model. A semi-realistic 3D model for tissue and blood vessels is used to analyze the transient heat transfer through the finger. The effect of heat conduction, metabolic heat generation, heat transport by blood perfusion, heat exchange between tissues and large vessels are considered in energy balance equations. The current model was then tested in different temperatures and air speeds to predict the danger of frostbite in humans for different gloves. Two prevalent gloves which are commonly used in cold climate are considered for investigation. The endurance time and the fraction of necrotic tissues are two main factors suggested for obtaining the response of digit tissues to different environmental conditions.
Collapse
Affiliation(s)
- Amir Fallahi
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran
| | - Mohammad Reza Salimpour
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran.
| | - Ebrahim Shirani
- Foolad Institute of Technology, Fooladshahr, Isfahan 84916-63763, Iran
| |
Collapse
|