1
|
Adanu KK, Iroko D, Amegan-Aho K, Adedia D, Ndudiri OV, Ali MA, Oyortey MA, Kpodonu J. Comparing the effectiveness and lubricity of a novel Shea lubricant to 2% lidocaine gel for digital rectal examination: a randomized non-inferiority trial. Sci Rep 2023; 13:4666. [PMID: 36949085 PMCID: PMC10033511 DOI: 10.1038/s41598-023-31555-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 03/14/2023] [Indexed: 03/24/2023] Open
Abstract
This study compared the level of lubricity and pain reduction of a novel shea lubricant to 2% lidocaine gel during digital rectal examination (DRE). Our research group performed a 9-week single-blind non-inferiority trial at the Ho Teaching Hospital involving 153 patients. The primary outcome measure was the mean pain difference during the procedure using a Visual Analogue Scale. 75 and 78 patients were randomized to the shea lubricant and 2% lidocaine gel groups respectively. The analysis considered the per-protocol population. The mean pain difference at endpoint was Δ - 0.01. The 95% lower confidence interval was a -0.595 difference in means, above the non-inferiority (NI) limit of - 0.720, thus establishing non-inferiority (Δ - 0.01, 95% CI - 0.59 to 0.57, NI - 0.72). With secondary outcome measures, perianal pruritus (p = 0.728), discomfort (p = 0.446), bowel urgency (p = 0.077) and urinary urgency (p = 0.841) were similar during the procedure. Shea lubricant had better lubricity and ease of use (p = 0.002). While the novel shea lubricant achieved similar level of pain reduction as obtained with 2% lidocaine gel, it had better ease of performance and lubricity.
Collapse
Affiliation(s)
- Kekeli Kodjo Adanu
- Department of Surgery, School of Medicine, University of Health and Allied Sciences, Ho, Ghana.
| | - Davidson Iroko
- Department of Anaesthesia and Critical Care, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | - Kokou Amegan-Aho
- Department of Pediatrics, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | - David Adedia
- Department of Basic Sciences, School of Basic and Biomedical Sciences, University of Health and Allied Sciences, Ho, Ghana
| | - Orish Verner Ndudiri
- Department of Microbiology, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | - Mahamudu Ayamba Ali
- Department of Surgery, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | - Mawuenyo Attawa Oyortey
- Department of Surgery, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | | |
Collapse
|
2
|
Armando M, Barthélémi L, Couret I, Verdier C, Dupont C, Jumas-Bilak E, Grau D. Recurrent environmental contamination in a centralized radiopharmacy unit by Achromobacter spp: results of a large microbiological investigation. Am J Infect Control 2022; 51:557-562. [PMID: 35870659 DOI: 10.1016/j.ajic.2022.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 07/02/2022] [Accepted: 07/06/2022] [Indexed: 11/01/2022]
Abstract
BACKGROUND Radiopharmaceuticals preparation unit, such as every aseptic preparation units, are strictly monitored in terms of microbiological contamination. Despite all biocontamination control procedures, our radiopharmacy unit faced repeated environnmental contamination by Achromobacter spp which necessitated a large environmental investigation. METHOD Microbiological controls were carried out using Count Tact agars (Biomérieux) for flat surfaces, dry swabbing for hard to reach areas and containers were filled with a sterile water solution (then filtrated on 0.45µm membrane and seeded). Microbiological identification was performed by mass spectrometry (MALDI-TOF-MS, Brucker) on each positive sample. RESULTS Achromobacter spp was found in 10% of the 413 samples during the 8 months investigation period. The proportion of positive samples was stable among time but their location was unpredictable. The highest inoculum was finally found in the buckets used for biocleaning. DISCUSSION Samples from cleaning buckets taken by dry swabbing were at first negative, but the use of a non-routinely used sampling method allowed to discover the reservoir of this persistent contamination. CONCLUSION This investigation alerted us on the high microbiological risk associated with reusable plastic containers and the importance of a sampling method adapted to critical locations.
Collapse
Affiliation(s)
- M Armando
- Radiopharmacy Unit, Department of Preparations and controls, University Teaching Hospital (UTH) of Montpellier, France
| | - L Barthélémi
- Radiopharmacy Unit, Department of Preparations and controls, University Teaching Hospital (UTH) of Montpellier, France
| | - I Couret
- Radiopharmacy Unit, Department of Preparations and controls, University Teaching Hospital (UTH) of Montpellier, France; Unit 1194 INSERM, Team Radiobiology and targeted radiotherapy, Cancer Research Institute of Montpellier, Montpellier, France
| | - C Verdier
- Pharmaceutical Controls Laboratory, Department of Preparations and controls, UTH of Montpellier, France
| | - C Dupont
- UMR 5569 HSM, Team "Pathogènes Hydriques Santé et Environnements", Unit of Bacteriology, University of Pharmacy, Montpellier, France
| | - E Jumas-Bilak
- Infection Control Department, UTH of Montpellier, France; UMR 5569 HSM, Team "Pathogènes Hydriques Santé et Environnements", Unit of Bacteriology, University of Pharmacy, Montpellier, France
| | - D Grau
- Infection Control Department, UTH of Montpellier, France; UMR 5569 HSM, Team "Pathogènes Hydriques Santé et Environnements", Unit of Bacteriology, University of Pharmacy, Montpellier, France
| |
Collapse
|
3
|
Schmitz J, Kossow A, Oelmeier de Murcia K, Heese S, Braun J, Möllmann U, Schmitz R, Möllers M. Disinfection of Transvaginal Ultrasound Probes by Ultraviolet C - A clinical Evaluation of Automated and Manual Reprocessing Methods. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2020; 41:681-687. [PMID: 31238382 DOI: 10.1055/a-0874-1971] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
PURPOSE Since pathogens can be transmitted to patients via transvaginal ultrasound probes, it is of particular importance that cleaning and disinfection are performed adequately. This study was designed to do a qualitative comparison of a low-level disinfection technique with disinfectant-impregnated wipes and an automated disinfection technique using ultraviolet C radiation in a clinical setting. MATERIALS AND METHODS The transvaginal ultrasound probes used in two groups of 160 patients were compared in a prospective controlled study regarding the effectiveness of manual low-level disinfection (Mikrozid sensitive wipes) and automated disinfection using ultraviolet C radiation (Antigermix AS1). Microbiological samples were taken from the whole surface of the probe before and after the disinfection process. RESULTS Before disinfection, 98.75 % (316/320) of the samples showed bacterial contamination. After automated and manual disinfection, the contamination rates were 34.2 % (54/158, automated) and 40.5 % (64/158, disinfectant wipes) (p > 0.05). Pathogens with the potential to cause healthcare-associated infections, such as Enterococcus faecalis and Klebsiella pneumoniae, were removed completely by both techniques. Manual disinfection showed a lower contamination rate after disinfection of bacteria that usually belong to the vaginal, pharyngeal and skin flora (disinfectant wipes 10.6 %, 11/104, automated 32.5 %, 38/117) (p < 0.001). CONCLUSION For the clinical routine, automated disinfection with ultraviolet C is a promising technique for transvaginal ultrasound probes because of the simple handling and time efficiency. In our study, this method was completely effective against nosocomial pathogens. However, the study didn't show any significant difference in terms of effectiveness compared to low-level wipe disinfection.
Collapse
Affiliation(s)
- Johanna Schmitz
- Department of Obstetrics and Gynecology, University Hospital Münster, Germany
| | | | | | - Sandra Heese
- Department of Obstetrics and Gynecology, University Hospital Münster, Germany
| | - Janina Braun
- Department of Obstetrics and Gynecology, University Hospital Münster, Germany
| | - Ute Möllmann
- Department of Obstetrics and Gynecology, University Hospital Münster, Germany
| | - Ralf Schmitz
- Department of Obstetrics and Gynecology, University Hospital Münster, Germany
| | - Mareike Möllers
- Department of Obstetrics and Gynecology, University Hospital Münster, Germany
| |
Collapse
|
4
|
Mullins K, Burnham K, Henricson EK, Cohen S, Fair J, Ray JW. Identification and Analysis of Bacterial Contamination of Ultrasound Transducers and Multiuse Ultrasound Transmission Gel Bottle Tips Before and After the Aseptic Cleansing Technique. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:1957-1963. [PMID: 32339352 DOI: 10.1002/jum.15300] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 03/14/2020] [Accepted: 03/22/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES To provide a descriptive analysis for species identification of culture and Gram stain results from ultrasound transducers and multiuse ultrasound transmission gel bottle tips in active clinical use and to compare bacterial cultures from ultrasound transducers before and after aseptic cleansing. METHODS A prospective blinded descriptive analytic study of 18 distinct clinical care sites within a single primary clinical institution was conducted. Before and after a disinfectant towel cleanse, transducers were pressed against tryptic soy agar contact plates. Plates were deidentified and submitted for blind incubation, Gram staining, and species identification with microsequencing. Results were classified as clinically relevant (CR) or non-clinically relevant. In total, 188 samples were analyzed: 80 from ultrasound transducers before and cleansing, 13 from multiuse gel bottle tips before and after cleansing, and 2 precleansing samples from the data collector's pen and badge. RESULTS Fifty-nine precleansing samples (73.8%) grew cultures with CR bacteria, and 21 samples (26.3%) did not. Staphylococcus simulans represented 31.0% of all positive culture samples. Thirteen postcleansing samples (16.3%) grew cultures with CR bacteria, equating to a 78.0% reduction of CR bacterial growth (likelihood ratio, 57.10; P < .001). CONCLUSIONS Ultrasound transducers have a notable CR bacterial burden and may serve as potential infective vectors. Aseptic cleansing effectively eliminates most of the bacterial load from ultrasound transducers, but some bacteria persist, presenting a risk of nosocomial infection with ultrasound-guided interventions. These findings support American Institute of Ultrasound in Medicine 2018 guidelines intended to ensure an appropriate level of transducer preparation based on the examination type while emphasizing rational infection control measures to minimize the risk of potential patient harm.
Collapse
Affiliation(s)
- Kevin Mullins
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - Kevin Burnham
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - Erik K Henricson
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - Stuart Cohen
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - James Fair
- Department of Surgery, Division of Emergency Medicine, University of Utah, Salt Lake City, Utah, USA
| | - Jeremiah W Ray
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| |
Collapse
|
5
|
Costello C, Basseal JM, Yang Y, Anstey J, Yastrebov K. Prevention of pathogen transmission during ultrasound use in the Intensive Care Unit: Recommendations from the College of Intensive Care Medicine Ultrasound Special Interest Group (USIG). Australas J Ultrasound Med 2020; 23:103-110. [PMID: 34760589 PMCID: PMC8411769 DOI: 10.1002/ajum.12205] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
ICU ultrasonography constitutes important part of modern car patient care. Current standards and practice of infection control and prevention are inadequate. This purpose of this document is to adapt and expand the 2017 Australasian Society for Ultrasound in Medicine (ASUM) and the Australasian College for Infection Prevention Control (ACIPC) guidelines on minimum standards for reprocessing/cleaning of ultrasound transducers to the specifics of intensive care medicine and provide advice to the ICU practitioners and health care administrators. It considers the medical, administrative, financial and practical controversies surrounding implementation, and addresses emerging issues of care for patients with confirmed or suspected Corona Virus Disease 2019 (COVID-19).
Collapse
Affiliation(s)
| | - Jocelyne M Basseal
- Discipline of Infectious Diseases & ImmunologyFaculty of Health and MedicineThe University of SydneySydneyNew South WalesAustralia
| | - Yang Yang
- Department of SurgeryUniversity of MelbourneAustralia Monash UniversityEastern Clinical SchoolMelbourneVictoriaAustralia
| | - James Anstey
- Royal Melbourne HospitalParkvilleVictoriaAustralia
| | - Konstantin Yastrebov
- St George HospitalPrince of Wales HospitalUniversity of New South WalesSydneyNew South WalesAustralia
| |
Collapse
|
6
|
Yagnik KJ, Kalyatanda G, Cannella AP, Archibald LK. Outbreak of Acinetobacter baumannii associated with extrinsic contamination of ultrasound gel in a tertiary centre burn unit. Infect Prev Pract 2019; 1:100009. [PMID: 34368675 PMCID: PMC8336045 DOI: 10.1016/j.infpip.2019.100009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 06/20/2019] [Indexed: 11/28/2022] Open
Abstract
Background During 2011 and 2012, an increase in occurrence of multidrug-resistant Acinetobacter baumannii infections was recorded in the Shands Hospital Burn Intensive Care Unit (BICU). An epidemic curve together with strain typing was consistent with an intermittent common source outbreak. An investigation was therefore initiated. Aim To identify risk factors for A. baumannii infection, characterize the source of the pathogen, implement control measures to terminate the outbreak, and institute preventive measures. Methods We conducted a retrospective case-control study; reviewed BICU infection control policies, practices and procedures, and patient exposure to healthcare workers (HCWs), and obtained epidemiologically-directed environmental cultures. Findings Eleven patients met the case definition. On multivariate analysis, case-patients were more likely to have undergone an ultrasound procedure in the BICU (adjusted odds ratio [AOR]: 19.5; confidence interval [CI]: 2.4-435) or have a FlexiSeal™ device (AOR: 11.9, CI:1.3-276). Epidemiologically-directed cultures of the environment, ultrasound equipment, and ultrasound gel from opened containers on the ultrasound trolley and in the Ultrasound Department were negative for the outbreak pathogen. Culture of an open ultrasound gel dispenser stored in the Ultrasound Department yielded an A. baumannii strain with DNA banding patterns identical to the outbreak strain. Conclusions Based on data from our epidemiologic, microbiologic, and observational studies, we believe that inadvertent extrinsic contamination of the gel dispenser occurred in the Ultrasound Department. Contaminated gel was then dispensed into multiuse vials of gel stored on the mobile carts. The outbreak was stemmed by instituting changes in practices in the Ultrasound Department, including introduction of single-use ultrasound vials and storage of ultrasound gel.
Collapse
Affiliation(s)
- Kruti J Yagnik
- University of Florida College of Medicine, Department of Medicine, Gainesville, FL, USA
| | - Gautam Kalyatanda
- University of Florida College of Medicine, Department of Medicine, Division of Infectious Diseases & Global Medicine, Gainesville, FL, USA
| | - Anthony P Cannella
- University of Florida College of Medicine, Department of Medicine, Division of Infectious Diseases & Global Medicine, Gainesville, FL, USA.,Malcolm Randall Veterans Health Administration Medical Centre, Gainesville, FL, USA.,University of Florida College of Medicine, Department of Molecular Genetics & Microbiology, Gainesville, FL, USA.,University of Florida College of Medicine, Emerging Pathogens Institute, Gainesville, FL, USA
| | - Lennox K Archibald
- University of Florida College of Medicine, Department of Medicine, Division of Infectious Diseases & Global Medicine, Gainesville, FL, USA.,Malcolm Randall Veterans Health Administration Medical Centre, Gainesville, FL, USA
| |
Collapse
|
7
|
Incidence of residual bacterial contamination of transvaginal ultrasound probes. J Med Ultrason (2001) 2019; 46:475-479. [DOI: 10.1007/s10396-019-00941-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Accepted: 03/08/2019] [Indexed: 10/27/2022]
|
8
|
Westerway SC, Basseal JM, Abramowicz JS. Medical Ultrasound Disinfection and Hygiene Practices: WFUMB Global Survey Results. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:344-352. [PMID: 30409470 DOI: 10.1016/j.ultrasmedbio.2018.09.019] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 09/19/2018] [Accepted: 09/19/2018] [Indexed: 06/08/2023]
Abstract
As ultrasound technology rapidly evolves and is used more frequently in every area of medical diagnosis and treatment, it may be overlooked as a potential vector in the transmission of a health care-associated infection. A survey on disinfection and hygiene practice in medical ultrasound was disseminated via the World Federation for Ultrasound in Medicine and Biology (WFUMB) to its six member federations and associated ultrasound societies globally. One thousand twenty-nine responses were obtained across a broad range of ultrasound practitioners. A total of 76% of respondents used transducer covers every time to scan open wounds and 71% when blood and bodily fluids were present or for an interventional procedure. Approved high-level disinfectants are not always used, even when blood comes into contact with the transducer or after endocavity scans. Alcohol-based wipes were used by many respondents to clean both external transducers and endocavity transducers. Open-ended responses indicated that a large caseload hindered the time required for cleaning and that access to clear guidelines would be beneficial. Global survey results indicate that some users do not comply with disinfection practice, and there is a gap in knowledge on basic infection prevention and control education within the ultrasound unit. As the infectious status of a patient is not often disclosed prior to an ultrasound examination, training in suitable protocols for the cleaning and disinfection of ultrasound equipment is imperative to mitigate the risk of potential infection.
Collapse
Affiliation(s)
- Susan Campbell Westerway
- Department of Dentistry and Health Sciences, Charles Sturt University, New South Wales, Australia; World Federation for Ultrasound in Medicine and Biology (WFUMB), Chicago, Illinois, USA
| | - Jocelyne M Basseal
- Australasian Society for Ultrasound in Medicine, Chatswood, New South Wales, Australia.
| | - Jacques S Abramowicz
- World Federation for Ultrasound in Medicine and Biology (WFUMB), Chicago, Illinois, USA; Department of Obstetrics & Gynecology, University of Chicago, Chicago, Illinois, USA
| |
Collapse
|
9
|
Haviari S, Cassier P, Dananché C, Hulin M, Dauwalder O, Rouvière O, Bertrand X, Perraud M, Bénet T, Vanhems P. Outbreak of Achromobacter xylosoxidans and Ochrobactrum anthropi Infections after Prostate Biopsies, France, 2014. Emerg Infect Dis 2018; 22:1412-9. [PMID: 27434277 PMCID: PMC4982167 DOI: 10.3201/eid2208.151423] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
We report an outbreak of healthcare-associated prostatitis involving rare environmental pathogens in immunocompetent patients undergoing transrectal prostate biopsies at Hôpital Édouard Herriot (Lyon, France) during August 13-October 10, 2014. Despite a fluoroquinolone-based prophylaxis, 5 patients were infected with Achromobacter xylosoxidans and 3 with Ochrobactrum anthropi, which has not been reported as pathogenic in nonimmunocompromised persons. All patients recovered fully. Analysis of the outbreak included case investigation, case-control study, biopsy procedure review, microbiologic testing of environmental and clinical samples, and retrospective review of hospital records for 4 years before the outbreak. The cases resulted from asepsis errors during preparation of materials for the biopsies. A low-level outbreak involving environmental bacteria was likely present for years, masked by antimicrobial drug prophylaxis and a low number of cases. Healthcare personnel should promptly report unusual pathogens in immunocompetent patients to infection control units, and guidelines should explicitly mention asepsis during materials preparation.
Collapse
|
10
|
Nyhsen CM, Humphreys H, Koerner RJ, Grenier N, Brady A, Sidhu P, Nicolau C, Mostbeck G, D’Onofrio M, Gangi A, Claudon M. Infection prevention and control in ultrasound - best practice recommendations from the European Society of Radiology Ultrasound Working Group. Insights Imaging 2017; 8:523-535. [PMID: 29181694 PMCID: PMC5707224 DOI: 10.1007/s13244-017-0580-3] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Revised: 10/03/2017] [Accepted: 10/05/2017] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVES The objective of these recommendations is to highlight the importance of infection prevention and control in ultrasound (US), including diagnostic and interventional settings. METHODS Review of available publications and discussion within a multidisciplinary group consistent of radiologists and microbiologists, in consultation with European patient and industry representatives. RECOMMENDATIONS Good basic hygiene standards are essential. All US equipment must be approved prior to first use, including hand held devices. Any equipment in direct patient contact must be cleaned and disinfected prior to first use and after every examination. Regular deep cleaning of the entire US machine and environment should be undertaken. Faulty transducers should not be used. As outlined in presented flowcharts, low level disinfection is sufficient for standard US on intact skin. For all other minor and major interventional procedures as well as all endo-cavity US, high level disinfection is mandatory. Dedicated transducer covers must be used when transducers are in contact with mucous membranes or body fluids and sterile gel should be used inside and outside covers. CONCLUSIONS Good standards of basic hygiene and thorough decontamination of all US equipment as well as appropriate use of US gel and transducer covers are essential to keep patients safe. MAIN MESSAGES • Transducers must be cleaned/disinfected before first use and after every examination. • Low level disinfection is sufficient for standard US on intact skin. • High level disinfection is mandatory for endo-cavity US and all interventions. • Dedicated transducer covers must be used for endo-cavity US and all interventions. • Sterile gel should be used for all endo-cavity US and all interventions.
Collapse
Affiliation(s)
- Christiane M. Nyhsen
- Radiology Department, City Hospitals Sunderland, Kayll Road, Sunderland, SR4 7TP UK
| | - Hilary Humphreys
- Department of Clinical Microbiology, The Royal College of Surgeons in Ireland, Dublin, Ireland
- Department of Microbiology, Beaumont Hospital, Dublin, Ireland
| | - Roland J. Koerner
- Infection Prevention and Control Department, Department of Microbiology, City Hospitals Sunderland, Kayll Road, Sunderland, SR4 7TP UK
| | - Nicolas Grenier
- Service d’Imagerie Diagnostique et Interventionnelle de l’Adulte Groupe Hospitalier, Pellegrin Place Amelie Raba-Leon, 33076 Bordeaux, Cedex France
| | - Adrian Brady
- Department of Radiology, Mercy University Hospital, Grenville Place, Cork, T12 WE28 Ireland
| | - Paul Sidhu
- King’s College Hospital, Denmark Hill, London, SE5 9RS UK
| | | | | | - Mirko D’Onofrio
- Radiology, Policlinico G.B. Rossi, VERONA, piazzale LA SCURO 10, 37134 Verona, Italy
| | - Afshin Gangi
- NHC, 1, Place de l’Hôpital, 67091 Strasbourg, France
| | - Michel Claudon
- Children Hospital, University Hospital - Nancy Brabois, Rue du Morvan, 54511 Vandoeuvre Les Nancy, Cedex France
| |
Collapse
|
11
|
Leduc P, Doublet JD, Bruyère F, Malavaud S. [Infection control practices while performing prostate biopsies in France: A CIAFU survey]. Prog Urol 2017; 27:529-535. [PMID: 28818480 DOI: 10.1016/j.purol.2017.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Revised: 05/28/2017] [Accepted: 07/05/2017] [Indexed: 10/19/2022]
Abstract
In 2008, the French Public Health Committee admitted that associating ultrasound probe protection, and related precautions, and low-level disinfection would be equivalent to the intermediate level disinfection. In 2010, the French Urology Association (AFU) updated guidelines regarding trans-rectal prostate biopsies, namely preventive measures related to cross-transmission of infections. We report an evaluation of compliance to them, driven in 2016 by AFU's infection committee. Although not recommended, almost one third of the urologists still perform biopsies under general anesthesia, and two thirds of them ask for a urine culture before biopsies. Several improvements are still needed: sterilization of needle guide should always be done when not of single use, the ultrasonography gel should be sterile, probes protection should be EC labeled, and compliance to probe processing between two patients should increase. Most of urologists happened to experience blood or feces contamination of probes. Less than half of probes are entirely floodable, and when intermediate level disinfection is done, glutaraldehyde is still referred as disinfectant by one third of the urologists. LEVEL OF EVIDENCE 4.
Collapse
Affiliation(s)
- P Leduc
- Unité d'épidémiologie et hygiène hospitalière, CHU Toulouse-Rangueil, 1, avenue Jean-Poulhès, 31059 Toulouse cedex 9, France
| | - J D Doublet
- Service d'urologie, centre hospitalier de Versailles, 177, rue de Versailles, 78157 Le Chesnaix cedex, France
| | - F Bruyère
- Service d'urologie, CHRU de Tours, 2, boulevard Tonnellé, 37044 Tours, France; PRES centre Val-de-Loire, université François-Rabelais de Tours, 37044 Tours, France
| | - S Malavaud
- Unité d'épidémiologie et hygiène hospitalière, CHU Toulouse-Rangueil, 1, avenue Jean-Poulhès, 31059 Toulouse cedex 9, France.
| | | |
Collapse
|
12
|
JOURNAL CLUB: Ultrasound-Guided Breast Interventions: Low Incidence of Infectious Complications With Use of an Uncovered Probe. AJR Am J Roentgenol 2017; 208:1147-1153. [PMID: 28225634 DOI: 10.2214/ajr.16.16440] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to determine the incidence of infectious complications after ultrasound-guided breast interventions performed with an intermediate-level disinfection protocol without an ultrasound probe cover. MATERIALS AND METHODS Two independent institutional databases were searched to identify breast infections in patients who underwent ultrasound-guided interventions between January 2005 and July 2013. The departments of radiology and infectious diseases independently maintained these databases. A comprehensive retrospective chart review based on periprocedural antibiotic use and clinical documentation of infection was also performed to reduce the likelihood of missing potential infectious complications. RESULTS A total of 12,708 ultrasound-guided breast procedures were performed in the time frame of this study. All potential cases of procedure-related infection were included for subspecialist review in an effort to give the most conservative (highest) estimate of infectious complications. Among these cases, 14 documented cases of possible procedure-related infection were identified, for an overall incidence of 0.11%. All infections were localized skin or soft-tissue infections and adequately treated with a short course of oral antibiotics. No cases of more serious infections or sepsis were found. None of the reported infections required IV antibiotic therapy, percutaneous intervention, surgical intervention, or hospitalization. CONCLUSION The incidence of infectious complications after an ultrasound-guided breast intervention without an ultrasound probe cover is extremely low. Physicians can use this information in the development of their disinfection protocols and to provide accurate information in counseling patients during preprocedural consultation.
Collapse
|
13
|
|
14
|
Westerway SC, Basseal JM. The ultrasound unit and infection control - Are we on the right track? ULTRASOUND : JOURNAL OF THE BRITISH MEDICAL ULTRASOUND SOCIETY 2017; 25:53-57. [PMID: 28228825 DOI: 10.1177/1742271x16688720] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Accepted: 12/13/2016] [Indexed: 11/15/2022]
Abstract
Best practice guidelines for the disinfection of ultrasound transducers and infection prevention in ultrasound departments are generally recommended by either government health groups or the ultrasound societies of individual countries. The literature shows a wide variance in not only transducer cleaning methods but basic hygiene practices in the ultrasound workplace. This paper describes results from a UK survey of disinfection of ultrasound transducers and hygiene practice in the workplace. The survey revealed that some ultrasound practitioners did not follow current guidelines with regard to the correct disinfection method of transducers, cords or ultrasound machine keyboards. Furthermore, the survey exposed the lack of training from the product manufacturers on how to use the disinfection product appropriately. These inconsistencies may be responsible for compliance issues and highlight the need for an awareness campaign and a unified approach to infection control by ultrasound practitioners.
Collapse
Affiliation(s)
- Susan C Westerway
- Faculty of Dentistry & Health Sciences, Charles Sturt University, NSW, Australia; Australasian Society for Ultrasound in Medicine (ASUM), Sydney, NSW, Australia
| | - Jocelyne M Basseal
- Australasian Society for Ultrasound in Medicine (ASUM), Sydney, NSW, Australia
| |
Collapse
|
15
|
Nyhsen CM, Humphreys H, Nicolau C, Mostbeck G, Claudon M. Infection prevention and ultrasound probe decontamination practices in Europe: a survey of the European Society of Radiology. Insights Imaging 2016; 7:841-847. [PMID: 27778309 PMCID: PMC5110482 DOI: 10.1007/s13244-016-0528-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Revised: 09/19/2016] [Accepted: 10/03/2016] [Indexed: 11/26/2022] Open
Abstract
OBJECTIVES Although ultrasound (US) is considered one of the safest imaging modalities, concerns have been raised regarding potential infection transmission risks through US procedures. A survey was undertaken by the European Society of Radiology (ESR) to establish infection prevention and control measures in US and to highlight the importance of good medical practice. METHODS An online survey was sent to all 22,000 full ESR members. RESULTS The response rate of completed surveys was 4.3 % (946 practitioners, 97 % of which were radiologists, mostly working in larger hospital settings). Among respondents, 29 %, 11 % and 6 % did not disinfect the US probe after every patient when performing standard surface US, endo-cavity US and interventional procedures, respectively. Eleven percent did not always use probe covers for endo-cavity US; for interventional procedures, the proportion was 23 %. A minority used sterile gel sachets in direct patient contact for endo-cavity scans (30 %), and 77.5 % used sterile gel for interventional procedures. CONCLUSIONS The survey results highlight a wide range of practices throughout Europe and the need to raise awareness amongst practitioners regarding the importance of infection prevention and control measures. The development of European recommendations encompassing all US examinations, together with education is a priority. MAIN MESSAGES • Transmission of infection through ultrasound procedures is possible. • There is a wide range of ultrasound probe decontamination practices in Europe. • Not all practitioners use probe covers for endo-cavity or interventional ultrasound. • Not all practitioners use sterile gel for internal and invasive procedures. • Currently there are no European recommendations encompassing all US examinations.
Collapse
Affiliation(s)
| | - Hilary Humphreys
- Royal College of Surgeons in Ireland, RCSI Education & Research Centre, Beaumont Hospital, Beaumont Dublin 9, Ireland
| | - Carlos Nicolau
- Hospital Clinic de Barcelona, Villarroel 170, ES 8036 Barcelona, Spain
| | | | - Michel Claudon
- Radiology Department, Hôpital de Brabois, CHRU de Nancy and IADI INSERM U 947, Rue du Morvan, FR 54511 Vandoeuvre Les Nancy Cedex, France
| |
Collapse
|
16
|
|
17
|
Dietrich CF, Horn R, Morf S, Chiorean L, Dong Y, Cui XW, Atkinson NSS, Jenssen C. Ultrasound-guided central vascular interventions, comments on the European Federation of Societies for Ultrasound in Medicine and Biology guidelines on interventional ultrasound. J Thorac Dis 2016; 8:E851-E868. [PMID: 27747022 DOI: 10.21037/jtd.2016.08.49] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Central venous access has traditionally been performed on the basis of designated anatomical landmarks. However, due to patients' individual anatomy and vessel pathology and depending on individual operators' skill, this landmark approach is associated with a significant failure rate and complication risk. There is substantial evidence demonstrating significant improvement in effectiveness and safety of vascular access by realtime ultrasound (US)-guidance, as compared to the anatomical landmark-guided approach. This review comments on the evidence-based recommendations on US-guided vascular access which have been published recently within the framework of Guidelines on Interventional Ultrasound (InVUS) of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) from a clinical practice point of view.
Collapse
Affiliation(s)
- Christoph F Dietrich
- Medical Department, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Würzburg, Germany;; Sino-German Research Center of Ultrasound in Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450000, China
| | - Rudolf Horn
- Notfallstation, Kantonsspital Glarus, Glarus, Switzerland
| | - Susanne Morf
- Intensivmedizin Kantonsspital Graubünden, Chur, Switzerland
| | - Liliana Chiorean
- Department of Medical Imaging, des Cévennes Clinic, Annonay, France
| | - Yi Dong
- Translational Gastroenterology Unit, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Xin-Wu Cui
- Medical Department, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Würzburg, Germany;; Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Nathan S S Atkinson
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Christian Jenssen
- Department of Internal Medicine, Krankenhaus Märkisch Oderland Strausberg, Wriezen, Germany
| |
Collapse
|
18
|
Bacterial Contamination of Ultrasound Probes at a Tertiary Referral University Medical Center. AJR Am J Roentgenol 2014; 203:928-32. [DOI: 10.2214/ajr.13.12407] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
19
|
O’Rourke M, Levan P, Khan T. Current Use of Ultrasound Transmission Gel for Transesophageal Echocardiogram Examinations: A Survey of Cardiothoracic Anesthesiology Fellowship Directors. J Cardiothorac Vasc Anesth 2014; 28:1208-10. [DOI: 10.1053/j.jvca.2014.02.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Indexed: 11/11/2022]
|
20
|
Investigation of current infection-control practices for ultrasound coupling gel: a survey, microbiological analysis, and examination of practice patterns. Reg Anesth Pain Med 2014; 38:415-24. [PMID: 23974866 DOI: 10.1097/aap.0b013e3182a0e12f] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND AND OBJECTIVES Ultrasound coupling gel may serve as a vector for the spread of bacteria and has been the causative agent for significant health care-associated infections. The purpose of this study was to document existing infection-control procedures and level of contamination present within nonsterile ultrasound gel from several clinical departments at a single institution. A second purpose was to examine the effectiveness of clinician education and manufacturer-based ultrasound additives on ultrasound gel contamination and in vitro bacterial proliferation, respectively. METHODS Compliance with Health Canada recommended infection-control policies were determined by survey. Contamination of in-use ultrasound gel bottles was determined by inspecting cultures after 72 hours of incubation. After infection-control education, a 28-day interval assessment was used to examine contamination rates in newly provided ultrasound gel. The ability of ultrasound gel containing parabens to prevent bacterial growth was examined in cultures grown with and without ultrasound gel. RESULTS Practitioners were not compliant with Health Canada recommendations, but the baseline ultrasound gel contamination rate within these departments was only 2.5%. Education in infection control did not improve the contamination rate over 28 days. Contamination was discovered in ultrasound gel supplied directly from the manufacturer. Ultrasound gel suppressed but did not prevent bacterial growth in a species- and time-specific manner. CONCLUSIONS The source of contamination for in-use ultrasound gel may be of manufacturer or human origin. Because additives to the ultrasound gel are not bactericidal, sterile ultrasound gel should be used for invasive and high-risk cases, and improving infection-control policies is warranted.
Collapse
|
21
|
M'Zali F, Bounizra C, Leroy S, Mekki Y, Quentin-Noury C, Kann M. Persistence of microbial contamination on transvaginal ultrasound probes despite low-level disinfection procedure. PLoS One 2014; 9:e93368. [PMID: 24695371 PMCID: PMC3973690 DOI: 10.1371/journal.pone.0093368] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2013] [Accepted: 03/04/2014] [Indexed: 11/18/2022] Open
Abstract
AIM OF THE STUDY In many countries, Low Level Disinfection (LLD) of covered transvaginal ultrasound probes is recommended between patients' examinations. The aim of this study was to evaluate the antimicrobial efficacy of LLD under routine conditions on a range of microorganisms. MATERIALS AND METHODS Samples were taken over a six month period in a private French Radiology Center. 300 specimens derived from endovaginal ultrasound probes were analyzed after disinfection of the probe with wipes impregnated with a quaternary ammonium compound and chlorhexidine. Human papillomavirus (HPV) was sought in the first set of s100 samples, Chlamydia trachomatis and mycoplasmas were searched in the second set of 100 samples, bacteria and fungi in the third 100 set samples. HPV, C. trachomatis and mycoplasmas were detected by PCR amplification. PCR positive samples were subjected to a nuclease treatment before an additional PCR assay to assess the likely viable microorganisms. Bacteria and fungi were investigated by conventional methods. RESULTS A substantial persistence of microorganisms was observed on the disinfected probes: HPV DNA was found on 13% of the samples and 7% in nuclease-resistant form. C. trachomatis DNA was detected on 20% of the probes by primary PCR but only 2% after nuclease treatment, while mycoplasma DNA was amplified in 8% and 4%, respectively. Commensal and/or environmental bacterial flora was present on 86% of the probes, occasionally in mixed culture, and at various levels (10->3000 CFU/probe); Staphylococcus aureus was cultured from 4% of the probes (10-560 CFU/probe). No fungi were isolated. CONCLUSION Our findings raise concerns about the efficacy of impregnated towels as a sole mean for disinfection of ultrasound probes. Although the ultrasound probes are used with disposable covers, our results highlight the potential risk of cross contamination between patients during ultrasound examination and emphasize the need for reviewing the disinfection procedure.
Collapse
Affiliation(s)
- Fatima M'Zali
- Université Bordeaux Segalen, Microbiologie Fondamentale et Pathogénicité Unité Mixte de Recherche 5234, Bordeaux, France
| | - Carole Bounizra
- Université Bordeaux Segalen, Microbiologie Fondamentale et Pathogénicité Unité Mixte de Recherche 5234, Bordeaux, France
| | - Sandrine Leroy
- Centre Hospitalier Universitaire de Nîmes, Service de Biostatistique, Epidémiologie Clinique, Santé Publique, Informatique Médicale, Nîmes, France
| | - Yahia Mekki
- Laboratoire de Virologie, Centre de Biologie et Pathologie Est, Hospices Civils de Lyon, Lyon, France
| | - Claudine Quentin-Noury
- Université Bordeaux Segalen, Microbiologie Fondamentale et Pathogénicité Unité Mixte de Recherche 5234, Bordeaux, France
| | - Michael Kann
- Université Bordeaux Segalen, Microbiologie Fondamentale et Pathogénicité Unité Mixte de Recherche 5234, Bordeaux, France
| |
Collapse
|
22
|
Wittmann J, Dreiseikelmann B, Rohde C, Rohde M, Sikorski J. Isolation and characterization of numerous novel phages targeting diverse strains of the ubiquitous and opportunistic pathogen Achromobacter xylosoxidans. PLoS One 2014; 9:e86935. [PMID: 24466294 PMCID: PMC3899368 DOI: 10.1371/journal.pone.0086935] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2013] [Accepted: 12/19/2013] [Indexed: 11/19/2022] Open
Abstract
The clinical relevance of nosocomially acquired infections caused by multi-resistant Achromobacter strains is rapidly increasing. Here, a diverse set of 61 Achromobacter xylosoxidans strains was characterized by MultiLocus Sequence Typing and Phenotype MicroArray technology. The strains were further analyzed in regard to their susceptibility to 35 antibiotics and to 34 different and newly isolated bacteriophages from the environment. A large proportion of strains were resistant against numerous antibiotics such as cephalosporines, aminoglycosides and quinolones, whereas piperacillin-tazobactam, ticarcillin, mezlocillin and imipenem were still inhibitory. We also present the first expanded study on bacteriophages of the genus Achromobacter that has been so far a blank slate with respect to phage research. The phages were isolated mainly from several waste water treatment plants in Germany. Morphological analysis of all of these phages by electron microscopy revealed a broad diversity with different members of the order Caudovirales, including the families Siphoviridae, Myoviridae, and Podoviridae. A broad spectrum of different host ranges could be determined for several phages that lysed up to 24 different and in part highly antibiotic resistant strains. Molecular characterisation by DNA restriction analysis revealed that all phages contain linear double-stranded DNA. Their restriction patterns display distinct differences underlining their broad diversity.
Collapse
Affiliation(s)
- Johannes Wittmann
- Leibniz Institute DSMZ – German Collection of Microorganisms and Cell Cultures, Department of Microorganisms, Braunschweig, Germany
- * E-mail:
| | - Brigitte Dreiseikelmann
- Department of Microbiology/Genetechnology, Faculty of Biology, University of Bielefeld, Bielefeld, Germany
| | - Christine Rohde
- Leibniz Institute DSMZ – German Collection of Microorganisms and Cell Cultures, Department of Microorganisms, Braunschweig, Germany
| | - Manfred Rohde
- Helmholtz Centre for Infection Research, Department of Medical Microbiology, Central Facility for Microscopy, Braunschweig, Germany
| | - Johannes Sikorski
- Leibniz Institute DSMZ – German Collection of Microorganisms and Cell Cultures, Department of Microbial Ecology and Diversity Research, Braunschweig, Germany
| |
Collapse
|
23
|
Reply. Urology 2013. [DOI: 10.1016/j.urology.2013.01.077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
24
|
Detection of Achromobacter xylosoxidans in hospital, domestic, and outdoor environmental samples and comparison with human clinical isolates. Appl Environ Microbiol 2013; 79:7142-9. [PMID: 24038696 DOI: 10.1128/aem.02293-13] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Achromobacter xylosoxidans is an aerobic nonfermentative Gram-negative rod considered an important emerging pathogen among cystic fibrosis (CF) patients worldwide and among immunocompromised patients. This increased prevalence remains unexplained, and to date no environmental reservoir has been identified. The aim of this study was to identify potential reservoirs of A. xylosoxidans in hospital, domestic, and outdoor environments and to compare the isolates with clinical ones. From 2011 to 2012, 339 samples were collected in Dijon's university hospital, in healthy volunteers' homes in the Dijon area, and in the outdoor environment in Burgundy (soil, water, mud, and plants). We designed a protocol to detect A. xylosoxidans in environmental samples based on a selective medium: MCXVAA (MacConkey agar supplemented with xylose, vancomycin, aztreonam, and amphotericin B). Susceptibility testing, genotypic analysis by pulsed-field gel electrophoresis, and blaOXA-114 sequencing were performed on the isolates. A total of 50 strains of A. xylosoxidans were detected in hospital (33 isolates), domestic (9 isolates), and outdoor (8 isolates) samples, mainly in hand washing sinks, showers, and water. Most of them were resistant to ciprofloxacin (49 strains). Genotypic analysis and blaOXA-114 sequencing revealed a wide diversity among the isolates, with 35 pulsotypes and 18 variants of oxacillinases. Interestingly, 10 isolates from hospital environment were clonally related to clinical isolates previously recovered from hospitalized patients, and one domestic isolate was identical to one recovered from a CF patient. These results indicate that A. xylosoxidans is commonly distributed in various environments and therefore that CF patients or immunocompromised patients are surrounded by these reservoirs.
Collapse
|
25
|
Chittick P, Russo V, Sims M, Robinson-Dunn B, Oleszkowicz S, Sawarynski K, Powell K, Makin J, Darnell E, Boura JA, Boyanton B, Band J. An outbreak of Pseudomonas aeruginosa respiratory tract infections associated with intrinsically contaminated ultrasound transmission gel. Infect Control Hosp Epidemiol 2013; 34:850-3. [PMID: 23838230 DOI: 10.1086/671268] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
We describe an outbreak of Pseudomonas aeruginosa respiratory tract infections related to intrinsically contaminated ultrasound gel used for intraoperative transesophageal echocardiograms in cardiovascular surgery patients. This investigation led to a product safety alert by the Food and Drug Administration and the development of guidelines for appropriate use of ultrasound gel.
Collapse
Affiliation(s)
- Paul Chittick
- Department of Infectious Disease, Beaumont Health System, Royal Oak, Michigan 48073, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Lorber G, Duvdevani M, Friedman M, Lavy E, Landau EH, Gofrit ON, Pode D, Steinberg D. First Place: Sustained-Release Antibacterial Varnish-Coated Biopsy Needle for Reduction of Infection Rates Following Prostate Biopsy—In Vitro Model. J Endourol 2013; 27:277-83. [DOI: 10.1089/end.2012.0123] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Gideon Lorber
- Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| | - Mordechai Duvdevani
- Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| | - Michael Friedman
- School of Pharmacy, Hebrew University-Hadassah, Jerusalem, Israel
| | - Eran Lavy
- School of Veterinary Medicine, Robert H. Smith Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Israel
| | - Ezekiel H. Landau
- Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| | - Ofer N. Gofrit
- Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| | - Dov Pode
- Department of Urology, Hadassah Hebrew University Medical Center, Jerusalem, Israel
| | - Doron Steinberg
- Biofilm Research Laboratory, Hebrew University-Hadassah, Jerusalem, Israel
| |
Collapse
|
27
|
Oleszkowicz SC, Chittick P, Russo V, Keller P, Sims M, Band J. Infections associated with use of ultrasound transmission gel: proposed guidelines to minimize risk. Infect Control Hosp Epidemiol 2012; 33:1235-7. [PMID: 23143361 DOI: 10.1086/668430] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Susan C Oleszkowicz
- Department of Epidemiology, Beaumont Health System, Royal Oak, Michigan 48073, USA.
| | | | | | | | | | | |
Collapse
|
28
|
Pseudomonas aeruginosa Respiratory Tract Infections Associated With Contaminated Ultrasound Gel Used for Transesophageal Echocardiography—Michigan, December 2011–January 2012. Ann Emerg Med 2012; 60:374-6; discussion 376-7. [DOI: 10.1016/j.annemergmed.2012.07.106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
29
|
Brote hospitalario de Achromobacter denitrificans relacionado con el uso de clorhexidina contaminada. INFECTIO 2012. [DOI: 10.1016/s0123-9392(12)70064-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
30
|
Gray RA, Williams PL, Dubbins PA, Jenks PJ. Decontamination of transvaginal ultrasound probes: review of national practice and need for national guidelines. Clin Radiol 2012; 67:1069-77. [PMID: 22591688 DOI: 10.1016/j.crad.2012.02.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2011] [Revised: 02/05/2012] [Accepted: 02/13/2012] [Indexed: 12/01/2022]
Abstract
AIM To determine the national practice of transvaginal ultrasound (TVUS) probe decontamination in English hospitals and to develop recommendations for guidance. MATERIALS AND METHODS A literature review was undertaken to clarify best practice and evaluate methods of decontamination of TVUS probes. A questionnaire was developed to ascertain TVUS probe decontamination programmes in current use within English hospitals. This was sent to ultrasound leads of 100 English hospitals; 68 hospitals responded. RESULTS There is a wide variation in TVUS probe decontamination across English hospitals. Although the majority of respondents (87%, 59/68) reported having clear and practical written guidelines for TVUS decontamination, the frequency, methods, and types of decontamination solutions utilized were widely variable and none meet the standards required to achieve high-level disinfection. CONCLUSION While the decontamination of other endoluminal medical devices (e.g., flexible endoscopes) is well defined and regulated, the decontamination of TVUS probes has no such guidance. There appears to be incomplete understanding of the level of risk posed by TVUS probes, and in some cases, this has resulted in highly questionable practices regarding TVUS hygiene. There is an urgent need to develop evidence-based national guidance for TVUS probe decontamination.
Collapse
Affiliation(s)
- R A Gray
- Derriford Hospital, Crownhill, Plymouth, Devon, UK.
| | | | | | | |
Collapse
|
31
|
Genetic and biochemical characterization of a novel metallo-β-lactamase, TMB-1, from an Achromobacter xylosoxidans strain isolated in Tripoli, Libya. Antimicrob Agents Chemother 2012; 56:2241-5. [PMID: 22290947 DOI: 10.1128/aac.05640-11] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
An Achromobacter xylosoxidans strain from the Tripoli central hospital produced a unique metallo-β-lactamase, designated TMB-1, which is related to DIM-1 (62%) and GIM-1 (51%). bla(TMB-1) was embedded in a class 1 integron and located on the chromosome. The TMB-1 β-lactamase has lower k(cat) values than both DIM-1 and GIM-1 with cephalosporins and carbapenems. The K(m) values were more similar to those of GIM-1 than those of DIM-1, with the overall k(cat)/K(m) values being lower than those for GIM-1 and DIM-1.
Collapse
|
32
|
Achromobacter xylosoxidans infection presenting as a pulmonary nodule mimicking cancer. J Clin Microbiol 2011; 49:2751-4. [PMID: 21593259 DOI: 10.1128/jcm.02571-10] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Achromobacter xylosoxidans is typically isolated from pulmonary sources, presenting as pneumonia in immunosuppressed individuals. We describe a novel clinical presentation of A. xylosoxidans infection presenting as multiple spiculated, pulmonary nodules mimicking cancer for which the patient underwent a wedge resection of the lung for diagnosis and staging of presumptive cancer.
Collapse
|