1
|
Berreta RS, Rubin J, Manivannan A, Jackson G, Cotter E, Khan ZA, McCormick J, Villarreal-Espinosa JB, Ayala S, Verma NN, Chahla J. Geniculate Artery Embolization for the Treatment of Mild to Moderate Knee Osteoarthritis Improves Pain and Function at Short-Term Follow-Up With Significant Procedural Heterogeneity Described Across the Literature: A Systematic Review. Arthroscopy 2024:S0749-8063(24)00567-X. [PMID: 39159728 DOI: 10.1016/j.arthro.2024.07.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 07/11/2024] [Accepted: 07/27/2024] [Indexed: 08/21/2024]
Abstract
PURPOSE To evaluate procedural heterogeneity, patient-reported outcomes (PROs), and complications following geniculate artery embolization (GAE) for knee osteoarthritis (OA). METHODS A literature search was performed using PubMed, Embase, and Scopus databases from inception to August 2023 according to the 2020 Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Human clinical studies reporting PROs following GAE for treatment of knee OA were included, and a qualitative comparison across PROs, procedural descriptions, and complications was performed. Study quality was assessed using the Cochrane Collaboration's risk of bias tool and the Methodological Index for Non-Randomized Studies criteria. The primary outcome measures included changes in PROs at 12 months and variances in procedural methodology. RESULTS A total of 17 studies, consisting of 533 patients and 620 knees, were identified. The reported mean improvement at 12 months for visual analog scale for pain and Western Ontario and McMaster Universities Arthritis Index scores ranged from 10 to 59 and 35.3 to 47, respectively. At 12 months, median improvements were observed in Knee injury and Osteoarthritis Outcome Score subscales such as Pain (range, 8.3-19.5), Quality of Life (15.49-25.0), Sport (7.5-26.3), and Symptoms (1.8-25.0). Decreasing minimal clinically important difference (MCID) achievement was observed between the 3-month and 6-month follow-up points. Patients with advanced OA and degenerative findings on magnetic resonance imaging exhibited lower rates of MCID achievement. Transient adverse events occurred in up to 80% of patients. Limited evidence from serial magnetic resonance imaging assessments suggests that GAE improves levels of synovitis. Significant heterogeneity exists among the GAE methodology as 4 different definitions of technical success, 4 distinct embolization targets, and use of 5 embolization agents were noted. CONCLUSIONS GAE results in short-term improvements in pain and function with decreasing MCID achievement observed after 3 to 6 months. Patients with severe OA also demonstrate lower rates of MCID achievement. A high rate of transient complications is reported, including skin discoloration and access site hematomas. Significant protocol heterogeneity exists, which contributes to variable outcomes. LEVEL OF EVIDENCE Level IV, systematic review of Level IV studies.
Collapse
Affiliation(s)
- Rodrigo Saad Berreta
- Department of Orthopaedics, Rush University Medical Center, Chicago, Illinois, U.S.A
| | - Jared Rubin
- University of Illinois College of Medicine, Chicago, Illinois, U.S.A
| | | | - Garrett Jackson
- Department of Orthopaedics, Rush University Medical Center, Chicago, Illinois, U.S.A
| | - Eric Cotter
- Department of Orthopaedics, Rush University Medical Center, Chicago, Illinois, U.S.A
| | - Zeeshan A Khan
- Department of Orthopaedics, Rush University Medical Center, Chicago, Illinois, U.S.A
| | - Johnathon McCormick
- Department of Orthopaedics, Rush University Medical Center, Chicago, Illinois, U.S.A
| | | | - Salvador Ayala
- Department of Orthopaedics, Rush University Medical Center, Chicago, Illinois, U.S.A
| | - Nikhil N Verma
- Department of Orthopaedics, Rush University Medical Center, Chicago, Illinois, U.S.A
| | - Jorge Chahla
- Department of Orthopaedics, Rush University Medical Center, Chicago, Illinois, U.S.A..
| |
Collapse
|
2
|
Nuzulia NA, Mart T, Ahmed I, Sari YW. The Use of Microspheres for Cancer Embolization Therapy: Recent Advancements and Prospective. ACS Biomater Sci Eng 2024; 10:637-656. [PMID: 38276875 DOI: 10.1021/acsbiomaterials.3c00659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
Embolization therapy involving biomaterials has improved the therapeutic strategy for most liver cancer treatments. Developing biomaterials as embolic agents has significantly improved patients' survival rates. Various embolic agents are present in liquid agents, foam, particulates, and particles. Some of the most applied embolic agents are microparticles, such as microspheres (3D micrometer-sized spherical particles). Microspheres with added functionalities are currently being developed for effective therapeutic embolization. Their excellent properties of high surface area and capacity for being loaded with radionuclides and alternate active or therapeutic agents provide an additional advantage to overcome limitations from traditional cancer treatments. Microspheres (non-radioactive and radioactive) have been widely used and explored for localized cancer treatment. Non-radioactive microspheres exhibit improved clinical performance as drug delivery vehicles in chemotherapy due to their controlled and sustained drug release to the target site. They offer better flow properties and are beneficial for the ease of delivery via injection procedures. In addition, radioactive microspheres have also been exploited for use as an embolic platform in internal radiotherapy as an alternative to cancer treatment. This short review summarizes the progressive development of non-radioactive and radioactive embolic microspheres, emphasizing material characteristics. The use of embolic microspheres for various modalities of therapeutic arterial embolization and their impact on therapeutic performance are also discussed.
Collapse
Affiliation(s)
- Nur Aisyah Nuzulia
- Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok 16424, Indonesia
- Department of Physics, Faculty of Mathematics and Natural Sciences, IPB University, Bogor 16680, Indonesia
| | - Terry Mart
- Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok 16424, Indonesia
| | - Ifty Ahmed
- Advanced Materials Research Group, Faculty of Engineering, University of Nottingham, Nottingham, NG7 2RD, U.K
| | - Yessie Widya Sari
- Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok 16424, Indonesia
- Department of Physics, Faculty of Mathematics and Natural Sciences, IPB University, Bogor 16680, Indonesia
| |
Collapse
|
3
|
Yang Y, Du N, Ma J, Peng Z, Zhou B, Yu J, Zhou X, Zhang W, Yan Z. Efficacy and Safety of Transarterial Chemoembolization with a Three-Stage Mixed Chemoembolic Regimen for Large Unresectable Hepatocellular Carcinoma. J Hepatocell Carcinoma 2023; 10:1897-1910. [PMID: 37904836 PMCID: PMC10613419 DOI: 10.2147/jhc.s433409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 09/30/2023] [Indexed: 11/01/2023] Open
Abstract
Objective This study aimed to assess the treatment response, survival outcomes, and safety of a novel transarterial chemoembolization (TACE) technique with a three-stage mixed chemoembolic regimen (M-TACE) in patients with large unresectable hepatocellular carcinoma (HCC) measuring more than 5 cm in maximum diameter. Methods Between January 2017 and March 2023, a total of 82 patients were enrolled in this retrospective cohort study. Treatment response was assessed in the first month after M-TACE; progression-free survival and overall survival (OS) were evaluated. The prognostic factors associated with patient survival were statistically analyzed by the Cox regression model. Adverse events were recorded. Results The maximum diameter of the tumors ranged from 5.3 cm to 20.0 cm (mean 10.71 cm). The objective response (OR) and disease control rates were 74.4 and 92.7%, respectively, at 1-month follow-up. The median survival time was 22 months (95% CI, 13.10-30.90 months). The OS rates were 82.0% at six months, 62.5% at one year, and 43.0% at two years. Targeted therapy and/or immunotherapy (P=0.001) and tumor response at one month (P=0.020) were protective factors for OS. In terms of safety, no major complications occurred and the only observed decrease within the normal range occurred in albumin and platelet levels one month after the embolization procedure. This decrease in levels did not show a significant relationship with the OR rates. Conclusion M-TACE demonstrated a promising objective tumor response, making it a viable and effective treatment option for patients with large unresectable HCC.
Collapse
Affiliation(s)
- Yanjie Yang
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, People’s Republic of China
| | - Nan Du
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, People’s Republic of China
| | - Jingqin Ma
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, People’s Republic of China
| | - Zhijie Peng
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, People’s Republic of China
| | - Bo Zhou
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, People’s Republic of China
| | - Jiaze Yu
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, People’s Republic of China
| | - Xin Zhou
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, People’s Republic of China
| | - Wen Zhang
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, People’s Republic of China
| | - Zhiping Yan
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, People’s Republic of China
| |
Collapse
|
4
|
Chau Y, Roux C, Gonzalez JF, Breuil V, Bernard de Dompsure R, Fontas E, Rudel A, Sédat J. Effectiveness of Geniculate Artery Embolization for Chronic Pain after Total Knee Replacement-A Pilot Study. J Vasc Interv Radiol 2023; 34:1725-1733. [PMID: 37391071 DOI: 10.1016/j.jvir.2023.06.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 05/19/2023] [Accepted: 06/20/2023] [Indexed: 07/02/2023] Open
Abstract
PURPOSE To evaluate the efficacy and safety of embolization of hyperemic synovial tissue for the treatment of persistent pain after total knee arthroplasty (TKA). MATERIALS AND METHODS Twelve patients with persistent pain after TKA were enrolled in this prospective, single-center pilot study. Genicular artery embolization (GAE) was performed using 75-μm spherical particles. The patients were assessed using a 100-point Visual Analog Scale (VAS) and Knee Injury and Osteoarthritis Outcome Score (KOOS) at baseline and 3 and 6 months thereafter. Adverse events were recorded at all time points. RESULTS A mean of 1.8 ± 0.8 abnormal hyperemic genicular arteries were identified and embolized, with a median volume of diluted embolic material of 4.3 mL in all 12 (100%) patients. The mean VAS score on walking improved from 73 ± 16 at baseline to 38 ± 35 at the 6-month follow-up (P < .05). The mean KOOS pain score improved from 43.6 ± 15.5 at baseline to 64.6 ± 27.1 at the 6-month follow-up (P < .05). At the 6-month follow-up, 55% and 73% of the patients attained a minimal clinically important change in pain and quality of life, respectively. Self-limited skin discoloration occurred in 5 (42%) patients. The VAS score increased by more than 20 immediately after embolization in 4 (30%) patients, who required analgesic treatment for 1 week. CONCLUSION GAE is a safe method of treating persistent pain after TKA that demonstrates potential efficacy at 12 months.
Collapse
Affiliation(s)
- Yves Chau
- Neurointerventionnal and Interventional Vascular Unit, CHU de Nice, Pasteur 2 Hospital, Nice, France.
| | - Christian Roux
- Department of Rheumatology, CHU de Nice, Pasteur 2 Hospital, Nice, France
| | | | - Véronique Breuil
- Department of Rheumatology, CHU de Nice, Pasteur 2 Hospital, Nice, France
| | | | - Eric Fontas
- Department of Clinical Research and Innovation, CHU de Nice, Pasteur 2 Hospital, Nice, France
| | - Alexandre Rudel
- Department of Osteo-Articular Radiology, CHU de Nice, Pasteur 2 Hospital, Nice, France
| | - Jacques Sédat
- Neurointerventionnal and Interventional Vascular Unit, CHU de Nice, Pasteur 2 Hospital, Nice, France
| |
Collapse
|
5
|
Talaie R, Torkian P, Amili O, Aboufirass Y, Rostambeigi N, Jalaeian H, Golzarian J. Particle Distribution in Embolotherapy, How Do They Get There? A Critical Review of the Factors Affecting Arterial Distribution of Embolic Particles. Ann Biomed Eng 2022; 50:885-897. [PMID: 35524027 DOI: 10.1007/s10439-022-02965-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Accepted: 04/05/2022] [Indexed: 11/26/2022]
Abstract
Embolization has tremendously evolved in recent years and has expanded to treatment of a variety of pathologic processes. There has been emerging evidence that the level of arterial occlusion and the distribution of embolic particles may play an important role in the clinical outcome. This is a comprehensive literature review to identify variables that play important role in determination of level of occlusion of blood vessels and distribution of embolic particles. The literature searches between 1996 to 2020 through PubMed and Ovid-MEDLINE yielded over 1030 articles of which 30 studies providing details on the level of occlusion are reviewed here. We divided the playing factors into characteristics of the particles, solution/injection and vascular bed. Accordingly, particle size, type and aggregation, compressibility/deformability, and biodegradability are categorized as the factors involving particles' behavioral nature. Infusion rate and concentration/dilution of the medium are related to the carrying solution. Hemodynamics and the arterial resistance are characteristics of the vascular bed that also play an important role in the distribution of embolic particles. Understanding and predicting the level of embolization is a complex multi-factor problem that requires more evidence, warranting further randomized controlled trials, and powered human and animal studies.
Collapse
Affiliation(s)
- Reza Talaie
- Department of Vascular and Interventional Radiology, University of Minnesota, Minneapolis, MN, USA
| | - Pooya Torkian
- Department of Vascular and Interventional Radiology, University of Minnesota, Minneapolis, MN, USA.
| | - Omid Amili
- Department of Mechanical, Industrial and Manufacturing Engineering (MIME), University of Toledo, Toledo, OH, USA
| | | | - Nassir Rostambeigi
- Mallinckrodt Institute of Radiology, Washington University School of Medicine in St. Louis, St. Louis, MO, USA
| | - Hamed Jalaeian
- Department of Interventional Radiology, Miller School of Medicine, University of Miami, Miami, FL, USA
| | - Jafar Golzarian
- Department of Vascular and Interventional Radiology, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
6
|
Bariatric Arterial Embolization with Calibrated Radiopaque Microspheres and an Antireflux Catheter Suppresses Weight Gain and Appetite-Stimulating Hormones in Swine. J Vasc Interv Radiol 2020; 31:1483-1491. [PMID: 32800664 DOI: 10.1016/j.jvir.2020.04.038] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 04/27/2020] [Accepted: 04/28/2020] [Indexed: 02/07/2023] Open
Abstract
PURPOSE To examine safety and efficacy of bariatric arterial embolization (BAE) with x-ray-visible embolic microspheres (XEMs) and an antireflux catheter in swine. MATERIAL AND METHODS BAE with selective infusion of XEMs (n = 6) or saline (n = 4, control) into gastric fundal arteries was performed under x-ray guidance. Weight and plasma hormone levels were measured at baseline and weekly for 4 weeks after embolization. Cone-beam CT images were acquired immediately after embolization and weekly for 4 weeks. Hormone-expressing cells in the stomach were assessed by immunohistochemical staining. RESULTS BAE pigs lost weight 1 week after embolization followed by significantly impaired weight gain relative to control animals (14.3% vs 20.9% at 4 weeks, P = .03). Plasma ghrelin levels were significantly lower in BAE pigs than in control animals (1,221.6 pg/mL vs 1,706.2 pg/mL at 4 weeks, P < .01). XEMs were visible on x-ray and cone-beam CT during embolization, and radiopacity persisted over 4 weeks (165.5 HU at week 1 vs 158.5 HU at week 4, P = .9). Superficial mucosal ulcerations were noted in 1 of 6 BAE animals. Ghrelin-expressing cell counts were significantly lower in the gastric fundus (17.7 vs 36.8, P < .00001) and antrum (24.2 vs 46.3, P < .0001) of BAE pigs compared with control animals. Gastrin-expressing cell counts were markedly reduced in BAE pigs relative to control animals (98.5 vs 127.0, P < .02). Trichrome staining demonstrated significantly more fibrosis in BAE animals compared with control animals (13.8% vs 8.7%, P < .0001). CONCLUSIONS XEMs enabled direct visualization of embolic material during and after embolization. BAE with XEMs and antireflux microcatheters was safe and effective.
Collapse
|
7
|
Lewis AL, Caine M, Garcia P, Ashrafi K, Tang Y, Hinchcliffe L, Guo W, Bascal Z, Kilpatrick H, Willis SL. Handling and performance characteristics of a new small caliber radiopaque embolic microsphere. J Biomed Mater Res B Appl Biomater 2020; 108:2878-2888. [PMID: 32578348 PMCID: PMC7496950 DOI: 10.1002/jbm.b.34619] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2019] [Revised: 03/19/2020] [Accepted: 04/13/2020] [Indexed: 12/24/2022]
Abstract
The in vitro and in vivo handling and performance characteristics of a small caliber radiopaque embolic microsphere, 40–90 μm DC Bead LUMI™ (LUMI40‐90), were studied. Microsphere drug loading and elution and effects on size, suspension, and microcatheter delivery were evaluated using established in vitro methodologies. In vivo evaluations of vascular penetration (rabbit renal artery embolization), long‐term biocompatibility and X‐ray imaging properties, pharmacokinetics and local tissue effects of both doxorubicin (Dox) and irinotecan (Iri) loaded microspheres (swine hepatic artery embolization) were conducted. Compared to 70–150 μm DC Bead LUMI (LUMI70‐150), LUMI40‐90 averaged 70 μm versus 100 μm, which was unchanged upon drug loading. Handling, suspension, and microsphere delivery studies were successfully performed. Dox loading was faster (20 min) and Iri equivalent (<10 min) while drug elution rates were similar. Contrast suspension times were longer with no delivery complications. Vascular penetration was statistically greater (rabbit) with no unexpected adverse safety findings (swine). Microspheres ± drug were visible under X‐ray imaging (CT) at 90 days. Peak plasma drug levels and area under the curve were greater for LUMI40‐90 compared to LUMI70‐150 but comparable to 70–150 μm DC BeadM1™ (DC70‐150). Local tissue effects showed extensive hepatic necrosis for Dox, whereas Iri displayed lower toxicity with more pronounced lobar fibrosis. LUMI40‐90 remains suspended for longer and have greater vessel penetration compared to the other DC Bead LUMI sizes and are similarly highly biocompatible with long‐term visibility under X‐ray imaging. Drug loading is equivalent or faster with pharmacokinetics similar to DC70‐150 for both Dox and Iri.
Collapse
Affiliation(s)
- Andrew L Lewis
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| | - Marcus Caine
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| | - Pedro Garcia
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| | - Koorosh Ashrafi
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| | - Yiqing Tang
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| | - Lorcan Hinchcliffe
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| | - Wei Guo
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| | - Zainab Bascal
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| | - Hugh Kilpatrick
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| | - Sean L Willis
- Biocompatibles UK Ltd., a BTG International Group Company, Camberley, Surrey, UK
| |
Collapse
|
8
|
Souftas V, Deuteraiou D, Anthoulaki X, Chalkidou A, Bothou A, Gaidatzi F, Tsypsianis G, Iatrakis G, Zervoudis S, Souftas D, Michalopoulos S, Vogiatzaki T, Galazios G, Nikolettos N, Tsikouras P. Significance of changes in inflammatory parameters following uterine artery embolization in pre-menopausal females. Exp Ther Med 2020; 19:3684-3690. [PMID: 32346432 PMCID: PMC7185183 DOI: 10.3892/etm.2020.8652] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Accepted: 12/19/2019] [Indexed: 12/29/2022] Open
Abstract
The purpose of the present study was to describe the course of changes in laboratory inflammatory markers following bilateral uterine artery embolization (UAE) as a treatment for leiomyomas and adenomyosis. The body temperature was measured and blood samples were collected to determine white blood cell (WBC) count and C-reactive protein (CRP) levels in 270 patients on the day prior to UAE and for up to 4 days post-embolization. Aside from a single case with a non-inflammatory complication, none of the other cases had any complications. Post-UAE leukocytosis with a mean maximum value of 10.8±3.5x109/l (range, 5.9-18.6x109/l) was observed one-year post-intervention. The mean leukocyte numbers were indicated to be higher on day 3 post-UAE. The CRP level was also increased post-UAE, with a mean maximum value of 7.75±3.5 mg/dl. Maximum levels were reached in 8 patients on the 2nd and in 11 patients on the 3rd post-operative day. The maximum pain score was ~5.5 and reached its lowest level at the end of the 12th week post-intervention. The present study did not consider an association between the embolic material used or uterus size with the level of treatment success. No complications were observed post-UAE; however, a significant increase in the WBC count was observed within the first 3 days, indicating mild leukocytosis.
Collapse
Affiliation(s)
- Vasileios Souftas
- Department of Interventional Radiology and Medical Imaging, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Dorelia Deuteraiou
- Department of Obstetrics and Gynecology, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Xanthoula Anthoulaki
- Department of Obstetrics and Gynecology, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Anna Chalkidou
- Department of Obstetrics and Gynecology, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Anastasia Bothou
- Department of Obstetrics and Mastology, Rea Hospital, Athens 17564, Greece
| | - Fotini Gaidatzi
- Department of Obstetrics and Gynecology, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Grigorios Tsypsianis
- Department of Medical Statistics, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Georgios Iatrakis
- University of West Attica, Department of Midwifery, Athens 17564, Greece
| | - Stefanos Zervoudis
- Department of Medical Statistics, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Dimitrios Souftas
- Department of Social Administration, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Spyridon Michalopoulos
- Department of Obstetrics and Gynecology, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Theodosia Vogiatzaki
- Department of Anesthesiology and Pain Treatment, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - George Galazios
- Department of Obstetrics and Gynecology, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Nikolaos Nikolettos
- Department of Obstetrics and Gynecology, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| | - Panagiotis Tsikouras
- Department of Obstetrics and Gynecology, Medical Faculty, Democritus University of Thrace, Alexandroupolis 68100, Greece
| |
Collapse
|
9
|
Kim AY, Yacoub JH, Field DH, Park BU, Kallakury B, Korolowicz KE, Menne S. Suitability of the woodchuck HCC as a preclinical model for evaluation of intra-arterial therapies. Animal Model Exp Med 2020; 3:98-102. [PMID: 32318666 PMCID: PMC7167237 DOI: 10.1002/ame2.12100] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 12/27/2019] [Accepted: 01/15/2020] [Indexed: 01/03/2023] Open
Abstract
The most commonly used preclinical models of hepatocellular carcinoma (HCC) are limited for use in testing of intra-arterial therapies such as transarterial chemoembolization and radioembolization. Issues encountered with the more commonly used animal models include dissimilarity in their disease development compared with humans and the size of the vasculature which can make intra-arterial therapy testing difficult or impossible. Here we describe the suitability of the woodchuck HCC model for testing of intra-arterial therapies. We describe the techniques for pre-embolization imaging assessment using CT and MRI, technical tips on performing angiography and embolization, and pathological assessment of treated liver.
Collapse
Affiliation(s)
- Alexander Y. Kim
- Department of RadiologyMedstar Georgetown University HospitalWashingtonDistrict of Columbia
| | - Joseph H. Yacoub
- Department of RadiologyMedstar Georgetown University HospitalWashingtonDistrict of Columbia
| | - David H. Field
- Department of RadiologyMedstar Georgetown University HospitalWashingtonDistrict of Columbia
| | - Byoung Uk Park
- Department of Pathology and Laboratory MedicineMedstar Georgetown University HospitalWashingtonDistrict of Columbia
| | - Bhaskar Kallakury
- Department of Pathology and Laboratory MedicineMedstar Georgetown University HospitalWashingtonDistrict of Columbia
| | - Kyle E. Korolowicz
- Department of Microbiology and ImmunologyGeorgetown University Medical CenterWashingtonDistrict of Columbia
| | - Stephan Menne
- Department of Microbiology and ImmunologyGeorgetown University Medical CenterWashingtonDistrict of Columbia
| |
Collapse
|
10
|
Lee RM, Cardona K, Russell MC. Historical perspective: Two decades of progress in treating metastatic colorectal cancer. J Surg Oncol 2019; 119:549-563. [PMID: 30806493 DOI: 10.1002/jso.25431] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 02/11/2019] [Accepted: 02/12/2019] [Indexed: 12/11/2022]
Abstract
Colorectal cancer is the third most commonly diagnosed cancer in the United States. While screening methods strive to improve rates of early stage detection, 25% of patients have metastatic disease at the time of diagnosis, with the most common sites being the liver, lung, and peritoneum. While once perceived as hopeless, the last two decades have seen substantial strides in the medical, surgical, and regional therapies to treat metastatic disease offering significant improvements in survival.
Collapse
Affiliation(s)
- Rachel M Lee
- Department of Surgery, Division of Surgical Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia
| | - Kenneth Cardona
- Department of Surgery, Division of Surgical Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia
| | - Maria C Russell
- Department of Surgery, Division of Surgical Oncology, Winship Cancer Institute, Emory University, Atlanta, Georgia
| |
Collapse
|
11
|
Vollherbst DF, Gockner T, Do T, Holzer K, Mogler C, Flechsig P, Harms A, Schlett CL, Pereira PL, Richter GM, Kauczor HU, Sommer CM. Computed tomography and histopathological findings after embolization with inherently radiopaque 40μm-microspheres, standard 40μm-microspheres and iodized oil in a porcine liver model. PLoS One 2018; 13:e0198911. [PMID: 29985928 PMCID: PMC6037373 DOI: 10.1371/journal.pone.0198911] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Accepted: 05/29/2018] [Indexed: 02/07/2023] Open
Abstract
Purpose The present study compared standard computed tomography (CT) and histopathological findings after endovascular embolization using a prototype of inherently radiopaque 40μm-microspheres with both standard 40μm-microspheres and iodized oil in a porcine liver model. Materials and methods Twelve pigs were divided into six study groups, of two pigs each. Four pigs were embolized with iodized oil alone and four with radiopaque microspheres; two animals in each group were sacrificed at 2 hours and two at 7 days. Two pigs were embolized with radiopaque microspheres and heparin and sacrificed at 7 days. Two pigs were embolized with standard microspheres and sacrificed at 2 hours. CT was performed before and after segmental embolization and before sacrifice at 7 days. The distribution of embolic agent, inflammatory response and tissue necrosis were assessed histopathologically. Results Radiopaque microspheres and iodized oil were visible on standard CT 2 hours and 7 days after embolization, showing qualitatively comparable arterial and parenchymal enhancement. Quantitatively, the enhancement was more intense for iodized oil. Standard microspheres, delivered without contrast, were not visible by imaging. Radiopaque and standard microspheres similarly occluded subsegmental and interlobular arteries and, to a lesser extent, sinusoids. Iodized oil resulted in the deepest penetration into sinusoids. Necrosis was always observed after embolization with microspheres, but never after embolization with iodized oil. The inflammatory response was mild to moderate for microspheres and moderate to severe for iodized oil. Conclusion Radiopaque 40μm-microspheres are visible on standard CT with qualitatively similar but quantitatively less intense enhancement compared to iodized oil, and with a tendency towards less of an inflammatory reaction than iodized oil. These microspheres also result in tissue necrosis, which was not observed after embolization with iodized oil. Both radiopaque and standard 40μm-microspheres are found within subsegmental and interlobar arteries, as well as in hepatic sinusoids.
Collapse
Affiliation(s)
- Dominik F. Vollherbst
- Department of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Theresa Gockner
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
- Clinic for Diagnostic and Interventional Radiology, University Hospital Mainz, Mainz, Germany
| | - Thuy Do
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Kerstin Holzer
- Department of General Pathology, University Hospital Heidelberg, Heidelberg, Germany
| | - Carolin Mogler
- Institute of Pathology, Technical University Munich, Munich, Germany
| | - Paul Flechsig
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
- Department of Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
| | - Alexander Harms
- Department of General Pathology, University Hospital Heidelberg, Heidelberg, Germany
| | - Christopher L. Schlett
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Philippe L. Pereira
- Clinic for Radiology, Minimally-invasive Therapies and Nuclear Medicine, SLK Kliniken Heilbronn GmbH, Heilbronn, Germany
| | - Götz M. Richter
- Clinic for Diagnostic and Interventional Radiology, Klinikum Stuttgart, Stuttgart, Germany
| | - Hans U. Kauczor
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Christof M. Sommer
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
- Clinic for Diagnostic and Interventional Radiology, Klinikum Stuttgart, Stuttgart, Germany
- * E-mail:
| |
Collapse
|
12
|
Sommer CM, Harms A, Do TD, Gockner TL, Kriegsmann M, Schlett CL, Holzer K, Vollherbst D, Warth A, Pereira PL, Eichwald V, Jugold M, Kauczor HU, Flechsig P. Inherently Radiopaque Narrow-Size-Calibrated Microspheres: Proof of Principle in a Pig Embolization Model. Cardiovasc Intervent Radiol 2018; 41:1404-1411. [DOI: 10.1007/s00270-018-1986-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2017] [Accepted: 05/11/2018] [Indexed: 02/06/2023]
|
13
|
Sommer CM, Do TD, Schlett CL, Flechsig P, Gockner TL, Kuthning A, Vollherbst DF, Pereira PL, Kauczor HU, Macher-Göppinger S. In vivo characterization of a new type of biodegradable starch microsphere for transarterial embolization. J Biomater Appl 2017; 32:932-944. [DOI: 10.1177/0885328217746674] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Christof M Sommer
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
- Clinic for Diagnostic and Interventional Radiology, Klinikum Stuttgart, Stuttgart, Germany
| | - Thuy D Do
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Christopher L Schlett
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Paul Flechsig
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
- Clinic for Nuclear Medicine, University Hospital Heidelberg, Heidelberg, Germany
| | - Theresa L Gockner
- Clinic for Diagnostic and Interventional Radiology, University Hospital Mainz, Mainz, Germany
| | | | - Dominik F Vollherbst
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
- Department of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Philippe L Pereira
- Clinic for Radiology, Minimally-invasive Therapies and Nuclear Medicine, SLK Kliniken Heilbronn GmbH, Heilbronn, Germany
| | - Hans U Kauczor
- Clinic for Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | | |
Collapse
|
14
|
Caine M, Zhang X, Hill M, Guo W, Ashrafi K, Bascal Z, Kilpatrick H, Dunn A, Grey D, Bushby R, Bushby A, Willis SL, Dreher MR, Lewis AL. Comparison of microsphere penetration with LC Bead LUMI™ versus other commercial microspheres. J Mech Behav Biomed Mater 2017; 78:46-55. [PMID: 29132100 DOI: 10.1016/j.jmbbm.2017.10.034] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Revised: 10/27/2017] [Accepted: 10/30/2017] [Indexed: 11/26/2022]
Abstract
The purpose of this study was to evaluate LC Bead LUMI™ (40-90µm and 70-150µm) in order to determine if their increased resistance to compression influences microsphere penetration and distribution compared to more compressible commercial microspheres. LC Bead LUMI™ 40-90µm and 70-150µm, LC BeadM1® 70-150µm, Embozene™ 40µm and Embozene™ 100µm size and distributions were measured using optical microscopy. Penetration in vitro was evaluated using an established 'plate model', consisting of a calibrated tapered gap between a glass plate and plastic housing to allow visual observation of microsphere penetration depth. Behaviour in vivo was assessed using a rabbit renal embolization model with histopathologic confirmation of vessel penetration depth. Penetration behaviour in vitro was reproducible and commensurate with the measured microsphere size, the smaller the microsphere the deeper the penetration. Comparison of the microsphere diameter measured on the 2D plate model versus the corresponding average microsphere size measured by histopathology in the kidney showed no significant differences (p = > 0.05 Mann-Whitney, demonstrating good in vitro - in vivo predictive capabilities of the plate model) confirming predictable performance for LC Bead LUMI™ (40-90µm and 70-150µm) based on microsphere size, their increased rigidity having no bearing on their depth of penetration and distribution. An assessment of a LC Bead LUMI™ (40-90µm and 70-150µm) has shown that despite having greater resistance to compression, these microspheres behave in a predictable manner within in vitro and in vivo models comparable with more compressible microspheres of similar sizes.
Collapse
Affiliation(s)
- Marcus Caine
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK; Faculty of Engineering and the Environment, University of Southampton, University Road, Highfield, Southampton SO17 1BJ, UK
| | - Xunli Zhang
- Faculty of Engineering and the Environment, University of Southampton, University Road, Highfield, Southampton SO17 1BJ, UK
| | - Martyn Hill
- Faculty of Engineering and the Environment, University of Southampton, University Road, Highfield, Southampton SO17 1BJ, UK
| | - Wei Guo
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK
| | - Koorosh Ashrafi
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK
| | - Zainab Bascal
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK
| | - Hugh Kilpatrick
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK
| | - Anthony Dunn
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK
| | - David Grey
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK
| | - Rosemary Bushby
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK
| | - Andrew Bushby
- School of Engineering and Materials Science, Queen Mary University, Mile End Road, London E1 4NS, UK
| | - Sean L Willis
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK
| | - Matthew R Dreher
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK
| | - Andrew L Lewis
- Biocompatibles UK Ltd, a BTG Group Company, Lakeview, Riverside Way, Watchmoor Park, Camberley GU15 3YL, UK.
| |
Collapse
|
15
|
Del Giudice C, Ifergan G, Goudot G, Bellamy V, Messas E, Clement O, Bruneval P, Menasche P, Sapoval M. Evaluation of a new model of hind limb ischemia in rabbits. J Vasc Surg 2017; 68:849-857. [PMID: 29074110 DOI: 10.1016/j.jvs.2017.07.140] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2017] [Accepted: 07/28/2017] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Various animal models of critical limb ischemia have been developed in the past. However, there is no animal model that can undergo endovascular treatment, while providing reproducible true critical limb ischemia with arterial ulcers and rest pain. We evaluated the efficacy of a new model of rabbit hindlimb ischemia created through a percutaneous approach using embolization with calibrated particles. METHODS Through a percutaneous transauricular artery approach and selective catheterization of the superficial femoral artery, embolization of distal limb vessels was performed using a mixture of 300- to 500-μm calibrated microparticles (Embosphere, Merit Medical, Salt Lake City, Utah), saline solution, and iodine contrast. Clinical and ultrasound imaging-based blood flow evaluation was performed before embolization and during follow-up. Histologic evaluation was performed at humane killing 14 days after the procedure. RESULTS The model was successfully created in 10 rabbits (10 limbs). One rabbit died of sudden death at 8 days after the procedure. The nine surviving rabbits developed hind ulcers. All rabbits had a higher pain score in the follow-up compared to baseline value (P < .0001). Blood flow in the saphenous artery decreased significantly after the procedure and later at 14 days follow-up (baseline value 63.4 ± 31.3 μL per cardiac cycle vs 32.0 ± 28.4 μL per cardiac cycle postprocedure [P = .0013] and 32.0 ± 28.4 μL per cardiac cycle at 14 days [P = .0015]). Pathology showed signs of severe limb ischemia in all rabbits with subacute and chronic injury patterns. CONCLUSIONS A rabbit hind limb ischemia model created by percutaneous transauricular distal femoral artery embolization with calibrated particles may overcome some of the limitations of existing animal models. As such, this model could prove useful for assessing therapies designed to improve arterial perfusion and collateral growth.
Collapse
Affiliation(s)
- Costantino Del Giudice
- Vascular and Oncological Interventional Radiology, Université Paris Descartes, Hôpital Européen George Pompidou, Paris, France; Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS-970, Centre de Recherche Cardiovasculaire, Université Paris Descartes, Sorbonne Paris Cité, Paris, France.
| | - Gabriel Ifergan
- Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS-970, Centre de Recherche Cardiovasculaire, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Guillaume Goudot
- Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS-970, Centre de Recherche Cardiovasculaire, Université Paris Descartes, Sorbonne Paris Cité, Paris, France; Angiology, Université Paris Descartes, Paris, France
| | - Valerie Bellamy
- Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS-970, Centre de Recherche Cardiovasculaire, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Emmanuel Messas
- Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS-970, Centre de Recherche Cardiovasculaire, Université Paris Descartes, Sorbonne Paris Cité, Paris, France; Angiology, Université Paris Descartes, Paris, France
| | - Olivier Clement
- Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS-970, Centre de Recherche Cardiovasculaire, Université Paris Descartes, Sorbonne Paris Cité, Paris, France; Department of Radiology, Université Paris Descartes, Paris, France
| | - Patrick Bruneval
- Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS-970, Centre de Recherche Cardiovasculaire, Université Paris Descartes, Sorbonne Paris Cité, Paris, France; Department of Pathology, Université Paris Descartes, Hôpital Européen George Pompidou, Paris, France
| | - Philippe Menasche
- Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS-970, Centre de Recherche Cardiovasculaire, Université Paris Descartes, Sorbonne Paris Cité, Paris, France; Department of Cardiovascular Surgery, Assistance Publique-Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Paris, France
| | - Marc Sapoval
- Vascular and Oncological Interventional Radiology, Université Paris Descartes, Hôpital Européen George Pompidou, Paris, France; Institut National de la Santé et de la Recherche Médicale (INSERM), UMRS-970, Centre de Recherche Cardiovasculaire, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| |
Collapse
|
16
|
Drug-eluting embolic microspheres for local drug delivery - State of the art. J Control Release 2017; 262:127-138. [PMID: 28710006 DOI: 10.1016/j.jconrel.2017.07.016] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Revised: 07/07/2017] [Accepted: 07/10/2017] [Indexed: 12/19/2022]
Abstract
Embolic microspheres or beads used in transarterial chemoembolization are an established treatment method for hepatocellular carcinoma patients. The occlusion of the tumor-feeding vessels by intra-arterial injection of the beads results in tumor necrosis and shrinkage. In this short review, we describe the utility of using these beads as devices for local drug delivery. We review the latest advances in the development of non-biodegradable and biodegradable drug-eluting beads for transarterial chemoembolization. Their capability to load different drugs, such as chemotherapeutics and anti-angiogenic compounds with different physicochemical properties, like charge and hydrophilicity/hydrophobicity, are discussed. We specifically address controlled and sustained drug release from the microspheres, and the resulting in vivo pharmacokinetics in the plasma vs. drug distribution in the targeted tissue.
Collapse
|
17
|
de Almeida Vital JM, de Farias TP, Dias FL, de Oliveira JF, Miranda da Paixão JG, de Cavalcanti Siebra PJ, Lopes Moraes AR. Nasal Cavity Paraganglioma: Literature Review and Discussion of a Rare Case. Biomed Hub 2017; 2:1-15. [PMID: 31988909 PMCID: PMC6945913 DOI: 10.1159/000464099] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Accepted: 02/13/2017] [Indexed: 12/02/2022] Open
Abstract
Paragangliomas can be found from the skull base to the sacrum. Sinonasal paragangliomas are infrequent. A 16-year-old female reported spontaneous discrete bilateral epistaxis once a month beginning when she was 3 years of age. Computed tomography showed an expansive hypervascular mass occupying the right nasal cavity and nasopharynx. Sinonasal paragangliomas usually occur in middle-aged women. Radiologic investigation is essential for the diagnosis of sinonasal paragangliomas and evaluating extension of the lesion. Endoscopic and conventional approaches are effective, and preoperative embolization is paramount for reducing bleeding risk. Histopathological features cannot differentiate benign from malignant paragangliomas, and since metastasis may eventually occur, follow-up must be carried out for a long period of time.
Collapse
Affiliation(s)
| | - Terence Pires de Farias
- Department of Oncology, Instituto Nacional de Câncer (INCA), Rio de Janeiro, Brazil.,Department of Head and Neck Surgery, Pontíficia Universidade Católica of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Fernando Luiz Dias
- Department of Head and Neck Surgery, Instituto Nacional de Câncer (INCA), Rio de Janeiro, Brazil.,Department of Head and Neck Surgery, Pontíficia Universidade Católica of Rio de Janeiro, Rio de Janeiro, Brazil.,Department of Clinical Surgery, Universidade de São Paulo, São Paulo, Brazil
| | | | | | | | - Arli Regina Lopes Moraes
- Department of Head and Neck Surgery, Instituto Nacional de Câncer (INCA), Rio de Janeiro, Brazil
| |
Collapse
|
18
|
Caine M, Carugo D, Zhang X, Hill M, Dreher MR, Lewis AL. Review of the Development of Methods for Characterization of Microspheres for Use in Embolotherapy: Translating Bench to Cathlab. Adv Healthc Mater 2017; 6. [PMID: 28218823 DOI: 10.1002/adhm.201601291] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Revised: 01/04/2017] [Indexed: 12/25/2022]
Abstract
Therapeutic embolotherapy is the deliberate occlusion of a blood vessel within the body, which can be for the prevention of internal bleeding, stemming of flow through an arteriovenous malformation, or occlusion of blood vessels feeding a tumor. This is achieved using a wide selection of embolic devices such as balloons, coils, gels, glues, and particles. Particulate embolization is often favored for blocking smaller vessels, particularly within hypervascularized tumors, as they are available in calibrated sizes and can be delivered distally via microcatheters for precise occlusion with associated locoregional drug delivery. Embolic performance has been traditionally evaluated using animal models, but with increasing interest in the 3R's (replacement, reduction, refinement), manufacturers, regulators, and clinicians have shown interest in the development of more sophisticated in vitro methods for evaluation and prediction of in vivo performance. Herein the current progress in developing bespoke techniques incorporating physical handling, fluid dynamics, occlusive behavior, and sustained drug elution kinetics within vascular systems is reviewed. While it is necessary to continue to validate the safety of such devices in vivo, great strides have been made in the development of bench tests that better predict the behavior of these products aligned with the principles of the 3R's.
Collapse
Affiliation(s)
- Marcus Caine
- Faculty of Engineering and the Environment; University of Southampton; University Road Highfield Southampton SO17 1BJ UK
- Biocompatibles UK Ltd., Lakeview; Riverside Way, Watchmoor Park Camberley GU15 3YL UK
| | - Dario Carugo
- Faculty of Engineering and the Environment; University of Southampton; University Road Highfield Southampton SO17 1BJ UK
| | - Xunli Zhang
- Faculty of Engineering and the Environment; University of Southampton; University Road Highfield Southampton SO17 1BJ UK
| | - Martyn Hill
- Faculty of Engineering and the Environment; University of Southampton; University Road Highfield Southampton SO17 1BJ UK
| | - Matthew R. Dreher
- Biocompatibles UK Ltd., Lakeview; Riverside Way, Watchmoor Park Camberley GU15 3YL UK
| | - Andrew L. Lewis
- Biocompatibles UK Ltd., Lakeview; Riverside Way, Watchmoor Park Camberley GU15 3YL UK
| |
Collapse
|
19
|
Endovascular Embolization by Transcatheter Delivery of Particles: Past, Present, and Future. J Funct Biomater 2017; 8:jfb8020012. [PMID: 28368345 PMCID: PMC5491993 DOI: 10.3390/jfb8020012] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2016] [Revised: 03/11/2017] [Accepted: 03/28/2017] [Indexed: 11/22/2022] Open
Abstract
Minimally invasive techniques to occlude flow within blood vessels, initially pioneered in the 1970s with autologous materials and subsequently advanced with increasingly sophisticated engineered biomaterials, are routinely performed for a variety of medical conditions. Contemporary interventional radiologists have at their disposal a wide armamentarium of occlusive agents to treat a range of disease processes through a small incision in the skin. In this review, we provide a historical perspective on endovascular embolization tools, summarize the current state-of-the-art, and highlight burgeoning technologies that promise to advance the field in the near future.
Collapse
|
20
|
Sommer C, Pallwein-Prettner L, Vollherbst D, Seidel R, Rieder C, Radeleff B, Kauczor H, Wacker F, Richter G, Bücker A, Rodt T, Massmann A, Pereira P. Transarterial embolization (TAE) as add-on to percutaneous radiofrequency ablation (RFA) for the treatment of renal tumors: Review of the literature, overview of state-of-the-art embolization materials and further perspective of advanced image-guided tumor ablation. Eur J Radiol 2017; 86:143-162. [DOI: 10.1016/j.ejrad.2016.10.024] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2016] [Revised: 10/17/2016] [Accepted: 10/21/2016] [Indexed: 02/08/2023]
|
21
|
Choi SY, Kwak BK, Shim HJ, Lee J, Hong SU, Kim KA. MRI traceability of superparamagnetic iron oxide nanoparticle-embedded chitosan microspheres as an embolic material in rabbit uterus. Diagn Interv Radiol 2016; 21:47-53. [PMID: 25333216 DOI: 10.5152/dir.2014.14015] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE We aimed to compare polyvinyl alcohol (PVA) particles with calibrated superparamagnetic iron oxide (SPIO) nanoparticle-loaded chitosan microspheres in a rabbit model, specifically regarding the relative distribution of embolic agents within the uterus based on magnetic resonance imaging (MRI) and pathological evaluation. METHODS Twelve New Zealand white rabbits underwent uterine artery embolization using either standard PVA particles (45-150 µm or 350-500 µm) or calibrated SPIO-embedded chitosan microspheres (45-150 µm or 300-500 µm). MRI and histopathological findings were compared one week after embolization. RESULTS Calibrated SPIO-loaded chitosan microspheres 45-150 µm in size were detected on T2-weighted images. On histological analysis, calibrated SPIO-embedded chitosan microspheres were found in both myometrium and endometrium, whereas PVA particles were found only in the perimyometrium or extrauterine fat pads. A proportional relationship was noted between the calibrated SPIO-embedded chitosan microsphere size and the size of the occluded artery. CONCLUSION Calibrated SPIO-embedded chitosan microspheres induced greater segmental arterial occlusion than PVA particles and showed great potential as a new embolic material. SPIO-embedded chitosan microspheres can be used to follow distribution of embolic particles through MRI studies.
Collapse
Affiliation(s)
- Sun Young Choi
- Department of Radiology and Medical Research Institute, Ewha Womans University School of Medicine, Seoul, Republic of Korea.
| | | | | | | | | | | |
Collapse
|
22
|
Poursaid A, Jensen MM, Huo E, Ghandehari H. Polymeric materials for embolic and chemoembolic applications. J Control Release 2016; 240:414-433. [PMID: 26924353 PMCID: PMC5001944 DOI: 10.1016/j.jconrel.2016.02.033] [Citation(s) in RCA: 92] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Revised: 02/19/2016] [Accepted: 02/21/2016] [Indexed: 12/18/2022]
Abstract
Percutaneous transcatheter embolization procedures involve the selective occlusion of blood vessels. Occlusive agents, referred to as embolics, vary in material characteristics including chemical composition, mechanical properties, and the ability to concurrently deliver drugs. Commercially available polymeric embolics range from gelatin foam to synthetic polymers such as poly(vinyl alcohol). Current systems under investigation include tunable, bioresorbable microspheres composed of chitosan or poly(ethylene glycol) derivatives, in situ gelling liquid embolics with improved safety profiles, and radiopaque embolics that are trackable in vivo. This article reviews commercially available materials used for embolization as well as polymeric materials that are under investigation.
Collapse
Affiliation(s)
- Azadeh Poursaid
- Department of Bioengineering, University of Utah, Salt Lake City, UT 84112, USA; Center for Nanomedicine, Nano Institute of Utah, University of Utah, Salt Lake City, UT 84112, USA
| | - Mark Martin Jensen
- Department of Bioengineering, University of Utah, Salt Lake City, UT 84112, USA; Center for Nanomedicine, Nano Institute of Utah, University of Utah, Salt Lake City, UT 84112, USA
| | - Eugene Huo
- Veterans Affairs Hospital, Salt Lake City, UT 84108, USA
| | - Hamidreza Ghandehari
- Department of Bioengineering, University of Utah, Salt Lake City, UT 84112, USA; Center for Nanomedicine, Nano Institute of Utah, University of Utah, Salt Lake City, UT 84112, USA; Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT 84112, USA.
| |
Collapse
|
23
|
Nonn A, Kirschner S, Figueiredo G, Kramer M, Nikoubashman O, Pjontek R, Wiesmann M, Brockmann MA. Feasibility, Safety, and Efficacy of Flow-Diverting Stent-Assisted Microsphere Embolization of Fusiform and Sidewall Aneurysms. Neurosurgery 2016; 77:126-35; discussion 135-6. [PMID: 25714517 DOI: 10.1227/neu.0000000000000687] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Treatment of wide-necked internal carotid artery aneurysms is frequently associated with incomplete occlusion and high recurrence rates. Furthermore, platinum coils cause strong beam-hardening artifacts, hampering subsequent image analyses. OBJECTIVE To assess the feasibility, safety, and efficacy of flow-diverting, stent-assisted microsphere embolization of fusiform and sidewall aneurysms in vitro and in vivo. METHODS Using a recirculating pulsatile in vitro flow model, 5 different aneurysm geometries (inner/outer curve, narrow/wide neck, and fusiform) were treated (each n = 1) by flow-diverting stent (FDS) implantation and subsequent embolization through a jailed microcatheter using calibrated microspheres (500-900 μm) larger than the pores of the FDS mesh. Treatment effects were analyzed angiographically and by micro computed tomography. The fluid of the in vitro model was filtered to ensure that no microspheres evaded the aneurysm. The experiment was repeated once in vivo. RESULTS In vitro, all 5 aneurysms were safely and completely occluded by FDS-assisted microsphere embolization. Virtually complete aneurysm occlusion was confirmed by angiography and micro computed tomography. No microspheres escaped into the circulation. The experiment was successfully repeated in 1 pig with a sidewall aneurysm generated by vessel occlusion. An embolic protection system placed distally of the FDS in vitro and in vivo (each n = 1) contained no microspheres after the embolization. Thus, no microspheres were lost in the circulation, and the use of an embolic protection system seems feasible to provide additional safety. CONCLUSION FDS-assisted microsphere embolization of fusiform and sidewall aneurysms is feasible and yields virtually complete aneurysm occlusion while avoiding coil-associated beam-hardening artifacts.
Collapse
Affiliation(s)
- Andrea Nonn
- *University Hospital of the RWTH Aachen, Department of Diagnostic and Interventional Neuroradiology, Aachen, Germany; ‡University of Heidelberg, Medical Faculty Mannheim, Department of Neuroradiology, Mannheim, Germany; §Department of Veterinary Clinical Sciences, Small Animal Clinic, Justus-Liebig-University, Giessen, Germany
| | | | | | | | | | | | | | | |
Collapse
|
24
|
Biocompatibility of Bletilla striata Microspheres as a Novel Embolic Agent. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2015; 2015:840896. [PMID: 26472985 PMCID: PMC4579312 DOI: 10.1155/2015/840896] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/18/2015] [Revised: 08/17/2015] [Accepted: 08/25/2015] [Indexed: 11/24/2022]
Abstract
We have prepared Chinese traditional herb Bletilla striata into microspheres as a novel embolic agent for decades. The aim of this study was to evaluate the biocompatibility of Bletilla striata microspheres (BSMs). After a thermal test of BSMs in vitro, the cell biocompatibility of BSMs was investigated in mouse fibroblasts and human umbilical vein endothelial cells using the methyl tetrazolium (MTT) assay. In addition, blood biocompatibility was evaluated. In vivo intramuscular implantation and renal artery embolization in rabbits with BSMs were used to examine the inflammatory response. The experimental rabbits did not develop any fever symptoms after injection of BSMs, and BSMs exhibited no cytotoxicity in cultured mouse fibroblasts and human umbilical vein endothelial cells. Additionally, BSMs exhibited high compatibility with red blood cells and no hemolysis activity. Intramuscular implantation with BSMs resulted in a gradually lessened mild inflammatory reaction that disappeared after eight weeks. The occlusion of small renal vessels was associated with a mild perivascular inflammatory reaction without significant renal and liver function damage. In conclusion, we believe that BSMs exhibit high biocompatibility and are a promising embolic agent.
Collapse
|
25
|
Transarterial chemoembolization (TACE) for colorectal liver metastases--current status and critical review. Langenbecks Arch Surg 2015; 400:641-59. [PMID: 26088872 DOI: 10.1007/s00423-015-1308-9] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2015] [Accepted: 05/24/2015] [Indexed: 12/11/2022]
Abstract
BACKGROUND Transarterial liver-directed therapies are currently not recommended as a standard treatment for colorectal liver metastases. Transarterial chemoembolization (TACE), however, is increasingly used for patients with liver-dominant colorectal metastases after failure of surgery or systemic chemotherapy. The limited available data potentially reveals TACE as a valuable option for pre- and post-operative downsizing, minimizing time-to-surgery, and prolongation of overall survival after surgery in patients with colorectal liver only metastases. PURPOSE In this overview, the current status of TACE for the treatment of liver-dominant colorectal liver metastases is presented. Critical comments on its rationale, technical success, complications, toxicity, and side effects as well as oncologic outcomes are discussed. The role of TACE as a valuable adjunct to surgery is addressed regarding pre- and post-operative downsizing, conversion to resectability as well as improvement of the recurrence rate after potentially curative liver resection. Additionally, the concept of TACE for liver-dominant metastatic disease with a focus on new embolization technologies is outlined. CONCLUSIONS There is encouraging data with regard to technical success, safety, and oncologic efficacy of TACE for colorectal liver metastases. The majority of studies are non-randomized single-center series mostly after failure of systemic therapies in the 2nd line and beyond. Emerging techniques including embolization with calibrated microspheres, with or without additional cytotoxic drugs, degradable starch microspheres, and technical innovations, e.g., cone-beam computed tomography (CT) allow a new highly standardized TACE procedure. The real efficacy of TACE for colorectal liver metastases in a neoadjuvant, adjuvant, and palliative setting has now to be evaluated in prospective randomized controlled trials.
Collapse
|
26
|
Kehoe S, Amensag S, Looney M, Abraham RJ, Boyd D. "Imageable" Zinc-Silicate Glass Microspheres For Transarterial Embolization: A Renal Artery Embolization Study. BIOMEDICAL GLASSES 2015. [DOI: 10.1515/bglass-2015-0007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractIntrinsically radiopaque (imageable) microspheres for transarterial embolization (TAE) are required to enable real-time intraprocedural feedback and definition of spatial distribution patterns of embolic materials in target tissues. This pilot study evaluates acute and sub-chronic safety and efficacy of imageable zinc-silicate (Zn-Si) glass microspheres in a swine renal artery embolization (RAE) model. Eight swine were divided into two cohorts. Clinical determinants of embolization effectiveness, including imageability, deliverability and temporal/ spatial distribution of microspheres in target tissues were assessed. Subsequently, cohort I and II were used to evaluate the acute and subchronic host response against the Zn-Si microspheres versus a clinical control. The developed microspheres provide for direct intraprocedural feedback using standard diagnostic imaging techniques. Fluoroscopy correlated with ex-vivo high-resolution radiography, CT and micro-CT, demonstrating high imageability, excellent spatial distribution and packing of the Zn- Si microspheres. At follow-up, infarction of the embolized kidneys was noted without any major adverse tissue reaction. Mild recanalization was observed microscopically for both experimental and control microspheres. Zn-Si microspheres permit the definition of spatial distribution in a target tissue, consequently permitting the optimization, personalization and improvement of TAE techniques.
Collapse
|
27
|
Enhancement of radiofrequency ablation of the liver combined with transarterial embolization using various embolic agents. ACTA ACUST UNITED AC 2014; 40:1821-8. [PMID: 25526685 DOI: 10.1007/s00261-014-0332-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
PURPOSE Reducing blood flow in the liver during radiofrequency ablation causes enlargement of the ablation area. In this animal study, we evaluated the extended effects of radiofrequency ablation combined with transarterial embolization using various embolic agents. METHODS We treated 38 radiofrequency ablation lesions after embolization in 13 pigs using the following embolic agents: gelatin sponge (Group A); iodized oil followed by gelatin sponge (Group B); 700-900 µm calibrated microspheres (Group C); and 100-300 µm calibrated microspheres (Group D). Lesion size and pathological evaluations of these ablation lesions were compared with those receiving radiofrequency ablation alone (control). RESULTS Both the long- and short-axis diameters of the ablation lesions for Groups A, B, C, and D were significantly longer than those of controls (long axis/short axis for Groups A, B, C, D, and controls were 27.2/23.2, 30.2/26.0, 28.2/22.2, 32.0/24.4, and 23.2 mm/18.5 mm, respectively) (P < 0.05). The long-axis of the ablation lesion for Group D was significantly longer than those for both Groups A and C (P < 0.05). At pathological examination, the central ablation lesions showed coagulative necrosis with a surrounding hemorrhagic rim, and the microspheres were fitted to occlude the small arteries in peripheral liver parenchyma in Groups C and D. CONCLUSIONS The extended effects of embolization with small microspheres may be stronger than those with large microspheres and were equal to those with iodized oil followed by gelatin sponge.
Collapse
|
28
|
Kishimoto K, Osuga K, Maeda N, Higashi Y, Hayashi A, Hori Y, Nakamura M, Ohashi F, Morii E, Tomiyama N. Embolic Effects of Transcatheter Mesenteric Arterial Embolization with Microspheres on the Small Bowel in a Dog Model. J Vasc Interv Radiol 2014; 25:1767-73. [DOI: 10.1016/j.jvir.2014.06.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2014] [Revised: 06/18/2014] [Accepted: 06/23/2014] [Indexed: 11/28/2022] Open
|
29
|
Gockner TL, Zelzer S, Mokry T, Gnutzmann D, Bellemann N, Mogler C, Beierfuß A, Köllensperger E, Germann G, Radeleff BA, Stampfl U, Kauczor HU, Pereira PL, Sommer CM. Sphere-enhanced microwave ablation (sMWA) versus bland microwave ablation (bMWA): technical parameters, specific CT 3D rendering and histopathology. Cardiovasc Intervent Radiol 2014; 38:442-52. [PMID: 25167958 DOI: 10.1007/s00270-014-0964-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Accepted: 06/30/2014] [Indexed: 11/29/2022]
Abstract
PURPOSE This study was designed to compare technical parameters during ablation as well as CT 3D rendering and histopathology of the ablation zone between sphere-enhanced microwave ablation (sMWA) and bland microwave ablation (bMWA). METHODS In six sheep-livers, 18 microwave ablations were performed with identical system presets (power output: 80 W, ablation time: 120 s). In three sheep, transarterial embolisation (TAE) was performed immediately before microwave ablation using spheres (diameter: 40 ± 10 μm) (sMWA). In the other three sheep, microwave ablation was performed without spheres embolisation (bMWA). Contrast-enhanced CT, sacrifice, and liver harvest followed immediately after microwave ablation. Study goals included technical parameters during ablation (resulting power output, ablation time), geometry of the ablation zone applying specific CT 3D rendering with a software prototype (short axis of the ablation zone, volume of the largest aligned ablation sphere within the ablation zone), and histopathology (hematoxylin-eosin, Masson Goldner and TUNEL). RESULTS Resulting power output/ablation times were 78.7 ± 1.0 W/120 ± 0.0 s for bMWA and 78.4 ± 1.0 W/120 ± 0.0 s for sMWA (n.s., respectively). Short axis/volume were 23.7 ± 3.7 mm/7.0 ± 2.4 cm(3) for bMWA and 29.1 ± 3.4 mm/11.5 ± 3.9 cm(3) for sMWA (P < 0.01, respectively). Histopathology confirmed the signs of coagulation necrosis as well as early and irreversible cell death for bMWA and sMWA. For sMWA, spheres were detected within, at the rim, and outside of the ablation zone without conspicuous features. CONCLUSIONS Specific CT 3D rendering identifies a larger ablation zone for sMWA compared with bMWA. The histopathological signs and the detectable amount of cell death are comparable for both groups. When comparing sMWA with bMWA, TAE has no effect on the technical parameters during ablation.
Collapse
Affiliation(s)
- T L Gockner
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120, Heidelberg, Germany,
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Zhou X, Kong M, Cheng X, Li J, Li J, Chen X. Investigation of acetylated chitosan microspheres as potential chemoembolic agents. Colloids Surf B Biointerfaces 2014; 123:387-94. [PMID: 25311962 DOI: 10.1016/j.colsurfb.2014.07.044] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2014] [Revised: 07/21/2014] [Accepted: 07/27/2014] [Indexed: 11/27/2022]
Abstract
The aim was to investigate the potential of chitosan microspheres (CMs) with different acetylation using as a chemoembolic agent. Chitosan microspheres (CMs) were prepared via water-in-oil (W/O) emulsification cross-linking method, and acetylated chitosan microspheres (ACMs) were obtained by acetylation of CMs. Next, we characterized the morphology, size, composition and degrees of deacetylation using scanning electron microscopy (TEM), dynamic laser light scattering (DLS), and Fourier transform infrared spectrometer (FTIR). All microspheres had smooth surfaces and good mechanical flexibility, and all could pass through a 5F catheter. The swelling rate (SR) of CMs decreased significantly with the increase of pH (4.0-10.0) but ACMs did not change under the same conditions. Protein absorption assays suggested that albumin was more greatly adsorbed on CMs than on ACMs. Furthermore, CMs caused more blood clots than ACMs. ACMs caused hemolysis less than CMs (<5% of the time). Data indicated that ACMs had more hemocompatibility. Cytotoxicity tests indicated that ACMs initially had less cell attached proliferation but increased with incubation. In contrast, the relative growth rate of mouse embryo fibroblasts (MEFs) on CMs decreased gradually. The results suggested that ACMs could stimulate the growth of MEFs, and CMs were not cytotoxic to MEFs. Thus, ACMs were more biocompatible with greater potential to be used as chemoembolic material.
Collapse
Affiliation(s)
- Xuan Zhou
- College of Marine Life Science, Ocean University of China, Qingdao 266003, China; Key Laboratory for Nano-Bio Interface Research, Suzhou Key Laboratory for Nanotheranostics, Division of Nanobiomedicine, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, China.
| | - Ming Kong
- College of Marine Life Science, Ocean University of China, Qingdao 266003, China
| | - Xiaojie Cheng
- College of Marine Life Science, Ocean University of China, Qingdao 266003, China
| | - Jingjing Li
- College of Marine Life Science, Ocean University of China, Qingdao 266003, China; College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100022, China
| | - Jing Li
- College of Marine Life Science, Ocean University of China, Qingdao 266003, China
| | - Xiguang Chen
- College of Marine Life Science, Ocean University of China, Qingdao 266003, China.
| |
Collapse
|
31
|
Uterine Artery Embolisation for Symptomatic Adenomyosis with Polyzene F-Coated Hydrogel Microspheres: Three-Year Clinical Follow-Up Using UFS–QoL Questionnaire. Cardiovasc Intervent Radiol 2014; 38:65-71. [DOI: 10.1007/s00270-014-0878-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2014] [Accepted: 02/16/2014] [Indexed: 10/25/2022]
|
32
|
Leyon JJ, Littlehales T, Rangarajan B, Hoey ET, Ganeshan A. Endovascular Embolization: Review of Currently Available Embolization Agents. Curr Probl Diagn Radiol 2014; 43:35-53. [DOI: 10.1067/j.cpradiol.2013.10.003] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
33
|
Tanaka T, Nishiofuku H, Maeda S, Masada T, Anai H, Sakaguchi H, Kichikawa K. Repeated bland-TAE using small microspheres injected via an implantable port-catheter system for liver metastases: an initial experience. Cardiovasc Intervent Radiol 2013; 37:493-7. [PMID: 23839008 DOI: 10.1007/s00270-013-0691-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2013] [Accepted: 06/19/2013] [Indexed: 01/02/2023]
Abstract
PURPOSE The purpose of this pilot study was to assess the effectiveness of repeated bland-TAE using small-size microspheres for liver metastases. To date, there have been no publications as to whether bland-TAE could be effective for nonhypervascular liver tumors. METHODS Bland-TAE with 100-μm, calibrated microspheres was performed in two chemoresistant patients: one with colorectal metastases and the other with gastric metastases. Both patients had multiple tumors in the entire liver. An implantable port-catheter system was placed in the hepatic artery to conduct repeated embolizations, thereby achieving enough efficacies. Microspheres were injected via the port until the disappearance of the tumor stains. Angiographies via the port were conducted 1, 3, 7, and 14 days after bland-TAE to evaluate the patency of the hepatic artery. RESULTS The hepatic artery started to recanalize 1 day after TAE and tumor stains appeared again during the 14 days. In both patients, bland-TAE was repeated four times in intervals of 14-21 days. The enhanced CTs showed necrotic changes and the decrease in size of the tumors. The serum CEA level decreased from 2,989 to 70 ng/ml and from 174 to 48 ng/ml, respectively. Bilomas and a liver abscess developed as complications. CONCLUSIONS Repeated bland-TAE using 100-μm microspheres injected via an implantable port-catheter system could be effective for liver metastases, although the caution of biliary injury is needed.
Collapse
Affiliation(s)
- Toshihiro Tanaka
- Department of Radiology, Nara Medical University, 840 Shijo-cho, Kashihara, 634-8522, Japan,
| | | | | | | | | | | | | |
Collapse
|
34
|
Multimodal Visibility (Radiography, Computed Tomography, and Magnetic Resonance Imaging) of Microspheres for Transarterial Embolization Tested in Porcine Kidneys. Invest Radiol 2013; 48:213-22. [DOI: 10.1097/rli.0b013e31827f6598] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
35
|
Superselective particle embolization enhances efficacy of radiofrequency ablation: effects of particle size and sequence of action. Cardiovasc Intervent Radiol 2012; 36:773-82. [PMID: 23070107 DOI: 10.1007/s00270-012-0497-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2012] [Accepted: 09/07/2012] [Indexed: 01/02/2023]
Abstract
PURPOSE To evaluate the effects of particle size and course of action of superselective bland transcatheter arterial embolization (TAE) on the efficacy of radiofrequency ablation (RFA). METHODS Twenty pigs were divided into five groups: group 1a, 40-μm bland TAE before RFA; group 1b, 40-μm bland TAE after RFA; group 2a, 250-μm bland TAE before RFA; group 2b, 250-μm bland TAE after RFA and group 3, RFA alone. A total of 40 treatments were performed with a combined CT and angiography system. The sizes of the treated zones were measured from contrast-enhanced CTs on days 1 and 28. Animals were humanely killed, and the treated zones were examined pathologically. RESULTS There were no complications during procedures and follow-up. The short-axis diameter of the ablation zone in group 1a (mean ± standard deviation, 3.19 ± 0.39 cm) was significantly larger than in group 1b (2.44 ± 0.52 cm; P = 0.021), group 2a (2.51 ± 0.32 cm; P = 0.048), group 2b (2.19 ± 0.44 cm; P = 0.02), and group 3 (1.91 ± 0.55 cm; P < 0.001). The greatest volume of ablation was achieved by performing embolization with 40-μm particles before RFA (group 1a; 20.97 ± 9.65 cm(3)). At histology, 40-μm microspheres were observed to occlude smaller and more distal arteries than 250-μm microspheres. CONCLUSION Bland TAE is more effective before RFA than postablation embolization. The use of very small 40-μm microspheres enhances the efficacy of RFA more than the use of larger particles.
Collapse
|
36
|
Stampfl U, Richter GM. Transportation characteristics of embolic microparticles. J Vasc Interv Radiol 2012; 23:574-5; author reply 575-6. [PMID: 22464724 DOI: 10.1016/j.jvir.2011.12.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2011] [Revised: 12/16/2011] [Accepted: 12/18/2011] [Indexed: 10/28/2022] Open
|
37
|
Sommer C, Kortes N, Mogler C, Bellemann N, Holzschuh M, Arnegger F, Nickel F, Gehrig T, Zelzer S, Meinzer H, Longerich T, Stampfl U, Kauczor H, Radeleff B. Super-micro-bland particle embolization combined with RF-ablation: Angiographic, macroscopic and microscopic features in porcine kidneys. Eur J Radiol 2012; 81:1165-72. [DOI: 10.1016/j.ejrad.2011.03.022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2011] [Accepted: 03/04/2011] [Indexed: 12/22/2022]
|
38
|
Abstract
OBJECTIVE Arterially directed therapies for hepatocellular carcinoma are used for patients who are not candidates for surgery or ablation and for those who need a bridge or down-staging to liver transplantation. These therapies seem to prolong the overall survival when compared with supportive care. CONCLUSION Chemoembolization, particle embolization, drug-eluting beads, and radioembolization have been used for locoregional control. This review discusses patient selection, techniques, safety, clinical outcomes, and imaging findings related to these therapies.
Collapse
|
39
|
Elasticity and viscoelasticity of embolization microspheres. J Mech Behav Biomed Mater 2011; 4:2161-7. [DOI: 10.1016/j.jmbbm.2011.08.001] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2011] [Revised: 07/26/2011] [Accepted: 08/02/2011] [Indexed: 11/18/2022]
|
40
|
Lewis AL, Holden RR. DC Bead embolic drug-eluting bead: clinical application in the locoregional treatment of tumours. Expert Opin Drug Deliv 2011; 8:153-69. [PMID: 21222553 DOI: 10.1517/17425247.2011.545388] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
INTRODUCTION DC Bead is an embolic drug-eluting bead designed to be loaded with chemotherapeutic agents (such as doxorubicin and irinotecan), delivered intra-arterially into tumor blood vessels to block nutrient flow and then to deliver the drug locally in a sustained fashion. This product is finding increasing use in the treatment of patients with both primary and secondary liver cancers. AREAS COVERED This review positions DC Bead in the field of targeted embolic drug delivery and with respect to other competitive technologies in the treatment of liver cancer. An overview of the studies that demonstrate the product's performance, safety and efficacy is presented. The clinical application of the doxorubicin loaded DC Bead is firstly reviewed, in the context of treatment of patients with various stages of hepatocellular carcinoma. Its combination with other therapies is also discussed, together with consideration of the treatment of other liver tumors. Secondly, the use of irinotecan loaded DC Bead, primarily for the treatment of colorectal cancer metastases to the liver, but also some additional rare metastases, is summarized. EXPERT OPINION An opinion is proffered as to how this technology and its application is evolving, illustrating a move towards synergistic combination therapies and into other cancer indications.
Collapse
Affiliation(s)
- Andrew L Lewis
- Biocompatibles UK Ltd, Farnham Business Park, Weydon Lane, Farnham, Surrey, UK.
| | | |
Collapse
|
41
|
Worthington-Kirsch RL, Siskin GP, Hegener P, Chesnick R. Comparison of the efficacy of the embolic agents acrylamido polyvinyl alcohol microspheres and tris-acryl gelatin microspheres for uterine artery embolization for leiomyomas: a prospective randomized controlled trial. Cardiovasc Intervent Radiol 2010; 34:493-501. [PMID: 21127866 DOI: 10.1007/s00270-010-0049-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2010] [Accepted: 11/04/2010] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To evaluate the efficacy of acrylamido polyvinyl alcohol microspheres (a-PVAM) as an embolic agent for uterine artery embolization (UAE) compared with Tris-acryl gelatin microspheres (TAGM). DESIGN, SETTING, PARTICIPANTS Prospective randomized double-blind noninferiority trial. Conducted at two sites both with regional UAE practices. Forty-six women with symptomatic leiomyomas. INTERVENTION UAE procedure was performed with either of the two embolic agents. Either 700-900-μm a-PVAM or 500-700-μm TAGM was used. MAIN OUTCOME MEASURES Changes in leiomyoma perfusion, overall uterine volume, and dominant leiomyomas volume measured by contrast-enhanced magnetic resonance imaging at 1 week, 3 months, and 6 months after UAE by a reader blinded to the embolic agent used. Changes in Uterine Fibroid Symptoms and Quality of Life questionnaire scores were measured at 3, 6, and 12 months after UAE. RESULTS Forty-six patients were randomized and treated under the study protocol (a-PVAM n=22, TAGM n=24). There were no procedure-related complications. Two patients were excluded from analysis (one technical failure of the procedure, one withdrawal from study). Successful (>90%) leiomyoma devascularization was observed in 81% of subjects at 1 week after UAE, 97% at 3 months after UAE, and 95% at 6 months after UAE. No significant differences were observed in 14 of 15 outcome measurements, consistent with noninferiority. TAGM was slightly superior to a-PVAM on one comparison (overall quality of life at 3 months after UAE).
Collapse
Affiliation(s)
- Robert L Worthington-Kirsch
- Image Guided Surgery Associates, PC, c/o Peripheral Vascular Institute of Philadelphia, 4220 Market Street, 2nd Floor, Philadelphia, PA 19104, USA.
| | | | | | | |
Collapse
|
42
|
Midterm results of uterine artery embolization using narrow-size calibrated embozene microspheres. Cardiovasc Intervent Radiol 2010; 34:295-305. [PMID: 20953610 DOI: 10.1007/s00270-010-9986-8] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2010] [Accepted: 08/26/2010] [Indexed: 12/20/2022]
Abstract
PURPOSE To evaluate safety and efficacy of uterine artery embolization using narrow-size-range polyphosphazene-coated hydrogel microspheres (Embozene, CeloNova Biosciences, Newnan, GA). METHODS Between May 2006 and September 2008, a total of 121 consecutive patients (mean ± SD age 42.1 ± 5.4 years, range 30.5-51.5 years) were enrolled onto this single-center study. The primary study endpoint was safety as assessed by the society of interventional radiology (SIR) classification. The secondary endpoint was efficacy, which was based on a 1-year magnetic resonance imaging study and relief of symptoms documented by the Medical Outcomes Study 36-Item Short-Form Health Survey questionnaire over a 2-year interval. RESULTS The mean ± SD diameter of the dominant fibroid was 6.4 ± 2.6 (range, 2.9-13.9) cm and the mean volume 137.2 ± 245.1 (range, 5.3-1184) ml. Most patients had multiple fibroids with 11% more than 10. A total of 240 of 242 interventions were completed as planned, a technical success rate of 99.2%. According to the SIR classification, one type A, eight type C, and one type D complication occurred. Total devascularization was noted in 96% (116 of 121) of dominant fibroids. Volume decrease was 4% at 2 weeks, 52% (P < 0.001) at 3 months, 78% (P < 0.001) at 6 months, and 91% at 12 months (P < 0.001). The latter difference was statistically significant (P = 0.007). A total of 92% had improved hypermenorrhea at 1 year and 94% at 2 years. Dysmenorrhea was improved in 96% at 1 year and in 95% at 2 years. The overall health status score was 60.4 ± 26.2 points at baseline and 96.9 ± 3.8 after 1 year (P = 0.0019). CONCLUSION Uterine artery embolization with Embozene microspheres is a safe procedure. Its efficacy is demonstrated by high fibroid devascularization and volume reduction rates and significant improvements of clinical symptoms and quality-of-life scores during follow-up.
Collapse
|
43
|
Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape. Cardiovasc Intervent Radiol 2010; 34:156-65. [DOI: 10.1007/s00270-010-9908-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2010] [Accepted: 05/20/2010] [Indexed: 12/18/2022]
|