• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4623447)   Today's Articles (1099)   Subscriber (49408)
For: Nikolov HN, Pelz DM, Lownie SP, Norley CJ, Khan V, Drangova M, Holdsworth DW. Micro-CT–compatible Technique for Measuring Self-expanding Stent Forces. J Vasc Interv Radiol 2010;21:562-70. [DOI: 10.1016/j.jvir.2010.01.016] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2008] [Revised: 09/03/2009] [Accepted: 01/30/2010] [Indexed: 11/28/2022]  Open
Number Cited by Other Article(s)
1
Egron S, Fujita B, Gullón L, Pott D, Schmitz-Rode T, Ensminger S, Steinseifer U. Radial Force: An Underestimated Parameter in Oversizing Transcatheter Aortic Valve Replacement Prostheses: In Vitro Analysis with Five Commercialized Valves. ASAIO J 2019;64:536-543. [PMID: 28885378 DOI: 10.1097/mat.0000000000000659] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
2
Csobay-Novák C, Bárány T, Zima E, Nemes B, Sótonyi P, Merkely B, Hüttl K. Role of Stent Selection in the Incidence of Persisting Hemodynamic Depression After Carotid Artery Stenting. J Endovasc Ther 2015;22:122-9. [DOI: 10.1177/1526602814566404] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
3
Della Maggiore AM, Steffey MA, Westropp JL. Treatment of traumatic penile urethral stricture in a dog with a self-expanding, covered nitinol stent. J Am Vet Med Assoc 2013;242:1117-21. [PMID: 23547676 DOI: 10.2460/javma.242.8.1117] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
4
Ganguly A, Simons J, Schneider A, Keck B, Bennett NR, Fahrig R. In-vitro Imaging of Femoral Artery Nitinol Stents for Deformation Analysis. J Vasc Interv Radiol 2011;22:236-43. [DOI: 10.1016/j.jvir.2010.10.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2008] [Revised: 08/14/2010] [Accepted: 10/20/2010] [Indexed: 11/28/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA