1
|
Bartos O, Mustafi M, Andic M, Grözinger G, Artzner C, Schlensak C, Lescan M. Carotid-axillary bypass as an alternative revascularization method for zone II thoracic endovascular aortic repair. J Vasc Surg 2020; 72:1229-1236. [DOI: 10.1016/j.jvs.2019.11.053] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2019] [Accepted: 11/26/2019] [Indexed: 12/17/2022]
|
2
|
Sharafuddin MJ, Reece TB, Papia G, Pozeg ZI, Peterson BG, Shafi B, Man J, Milner R. Proposed classification of endoleaks after endovascular treatment of Stanford type-B aortic dissections. Vascular 2019; 27:585-594. [PMID: 31067206 DOI: 10.1177/1708538119847394] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Objectives Despite two decades of experience, no dedicated classification system exists to document and prognosticate patterns of endoleak encountered after endovascular therapy of type-B aortic dissection. This nomenclature gap has led to inconsistent management and underreporting of significant findings associated with adverse outcomes after endovascular treatment of type-B aortic dissection. Our goal was to propose a reproducible and prognostically relevant classification. Methods A multidisciplinary team of seven experienced open and endovascular aortic surgeons was assembled to provide consensus opinion. Extensive literature review was conducted. Deficiencies in the current classification approach of the various patterns of persistent filling of false lumen after endovascular therapy were identified. Results Our focus was to categorize high-risk and low-risk subgroups within endoleaks after endovascular treatment of type-B aortic dissection. In this classification, type-Ia endoleak refers to persistent filling of the false lumen in an antegrade manner. Causes include failure to cover the primary entry tear and sizing or technical related proximal seal failure. False lumen filling via distal entry tears is classified as type Ib endoleak, which is further sub-classified into b1 (major branch-related tears), and b2 (multiple small branches related tears). Retrograde ascending aortic dissection and stent graft-induced new entry were classified as type-I endoleaks (type-Ir and type-Is, respectively). Another focus was reclassification type-II endoleaks, with type-IIa endoleak referring to conventional retroleak from one or more posterior branches and type-IIx referring to retroleak from major branches (visceral or left subclavian arteries). Conclusions The majority of endoleaks after endovascular treatment of type-B aortic dissection are related to persistent or new filling of the false lumen. We propose a new false lumen-based classification schema for endoleaks occurring after endovascular therapy of type-B aortic dissection.
Collapse
Affiliation(s)
- Mel J Sharafuddin
- Department of Surgery, University of Iowa Hospitals and Clinics, USA
| | - T Brett Reece
- Department of Cardiothoracic Surgery, University of Colorado School of Medicine, USA
| | - Giuseppe Papia
- Sunnybrook Health Sciences Centre, University of Toronto, Canada
| | - Zlatko I Pozeg
- Department of Cardiothoracic Surgery, University of Manitoba School of Medicine, St. Boniface Hospital, Canada
| | - Brian G Peterson
- Department of Vascular Surgery, SSM Health St. Louis University Hospital, USA
| | - Bilal Shafi
- Department of Cardiothoracic Surgery, Sutter Health/Palo Alto Medical Foundation, USA
| | - Jeanette Man
- Department of Surgery, University of Iowa Hospitals & Clinics, USA
| | - Ross Milner
- University of Chicago Pritzker School of Medicine, USA
| |
Collapse
|
3
|
Matsumoto K, Ohuchi Y, Yata S, Adachi A, Endo M, Takasugi S, Fujii S, Hashimoto M, Kaminou T, Ogawa T, Fujiwara Y, Saiki M, Nishimura M. Compressed Amplatzer Vascular Plug II Embolization of the Left Subclavian Artery for Thoracic Endovascular Aortic Repair is Efficient and Safety Method Comparable to Conventional Coil Embolization. Yonago Acta Med 2019. [DOI: 10.33160/yam.2019.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Kensuke Matsumoto
- *Division of Radiology, Department of Pathophysiological and Therapeutic Science, School of Medicine, Tottori University Faculty of Medicine, Yonago 683-8504, Japan
| | - Yasufumi Ohuchi
- *Division of Radiology, Department of Pathophysiological and Therapeutic Science, School of Medicine, Tottori University Faculty of Medicine, Yonago 683-8504, Japan
| | - Shinsaku Yata
- *Division of Radiology, Department of Pathophysiological and Therapeutic Science, School of Medicine, Tottori University Faculty of Medicine, Yonago 683-8504, Japan
| | - Akira Adachi
- *Division of Radiology, Department of Pathophysiological and Therapeutic Science, School of Medicine, Tottori University Faculty of Medicine, Yonago 683-8504, Japan
| | - Masayuki Endo
- *Division of Radiology, Department of Pathophysiological and Therapeutic Science, School of Medicine, Tottori University Faculty of Medicine, Yonago 683-8504, Japan
| | - Shohei Takasugi
- *Division of Radiology, Department of Pathophysiological and Therapeutic Science, School of Medicine, Tottori University Faculty of Medicine, Yonago 683-8504, Japan
| | - Shinya Fujii
- *Division of Radiology, Department of Pathophysiological and Therapeutic Science, School of Medicine, Tottori University Faculty of Medicine, Yonago 683-8504, Japan
| | - Masayuki Hashimoto
- †Department of Radiology, Tottori Municipal Hospital, Tottori 680-8501, Japan
| | - Toshio Kaminou
- ‡Department of Radiology, Osaka Minami Medical Center, Kawachinagano 586-8521, Japan
| | - Toshihide Ogawa
- §Department of Radiology, Kurashiki Heisei Hospital, Kurashiki 710-0826, Japan
| | - Yoshikazu Fujiwara
- Division of Organ Regeneration Surgery, Department of Surgery, School of Medicine, Tottori University Faculty of Medicine, Yonago 683-8504, Japan
| | - Munehiro Saiki
- ¶Department of Cardiovascular surgery, Hiroshima City Hiroshima Citizens Hospital, Hiroshima 730-8518, Japan
| | - Motonobu Nishimura
- Division of Organ Regeneration Surgery, Department of Surgery, School of Medicine, Tottori University Faculty of Medicine, Yonago 683-8504, Japan
| |
Collapse
|
4
|
Leong CR, Solaimanzadeh I, Rosca M, Siegel D, Giangola G. Embolization of an Aberrant Right Subclavian Artery Aneurysm with Amplatzer Vascular Plug without Bypass. Int J Angiol 2013; 21:237-40. [PMID: 24293984 DOI: 10.1055/s-0032-1328967] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Abstract
Aberrant right subclavian artery (ARSA) aneurysms are rare, but the risk of rupture and thromboembolism is high, with a postrupture mortality rate of 50%. Open surgical repair of ARSA aneurysms usually requires thoracotomy and aortic grafting, which can be contraindicated in high-risk patients with multiple comorbidities. Endovascular repair of ARSA aneurysms has been reported, with or without adjunctive surgical bypass. We report a case of an 80-year-old woman resenting with an asymptomatic 4 cm ARSA aneurysm who underwent a completely endovascular treatment of the aneurysm using an Amplatzer vascular plug II (St. Jude Medical Inc., St. Paul, MN).
Collapse
Affiliation(s)
- Chuo Ren Leong
- Division of Vascular Surgery, NSLIJ Health System, Manhasset, New York
| | | | | | | | | |
Collapse
|
5
|
Coscas R, Capdevila C, Colacchio G, Goëau-Brissonnière O, Coggia M. Hybrid repair of type II dissecting thoracoabdominal aneurysm using Amplatzer vascular plugs for entry tear closure. Ann Vasc Surg 2013; 27:972.e1-5. [PMID: 23993113 DOI: 10.1016/j.avsg.2013.03.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2012] [Revised: 12/16/2012] [Accepted: 03/04/2013] [Indexed: 11/30/2022]
Abstract
Endovascular repair of chronic aortic dissections (CAD) intend to promote false lumen thrombosis (FLT). This article describes a technique using Amplatzer vascular plugs (AVPs) for entry tear closure of CAD. A 70-year-old man presented with a type II dissecting thoracoabdominal aneurysm. Computed tomography scan showed a very tight true lumen, partial FLT, and 2 entry tears at the level of the left subclavian artery and the visceral aorta, respectively. During a first procedure, aortic debranching was performed using the ascending aorta as bypass inflow. In a second intervention entry tears were closed using AVPs protected by short stent grafts. Technical success was achieved. No paraplegia occurred. Eighteen months later, FLT was complete and aortic diameter decreased. Entry tear closure using AVPs is feasible and allows FLT. Further reports are needed to determine if stent-graft protection of AVPs is mandatory, which may simplify technical aspects of the procedure.
Collapse
Affiliation(s)
- Raphaël Coscas
- Department of Vascular Surgery, Ambroise Paré University Hospital, Boulogne-Billancourt, France.
| | | | | | | | | |
Collapse
|
6
|
Jim J, Caputo FJ, Sanchez LA. Intentional coverage of the celiac artery during thoracic endovascular aortic repair. J Vasc Surg 2013; 58:270-5. [DOI: 10.1016/j.jvs.2013.04.003] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2012] [Revised: 02/28/2013] [Accepted: 04/01/2013] [Indexed: 11/29/2022]
|
7
|
Bischoff MS, Geisbüsch P, Kotelis D, Müller-Eschner M, Hyhlik-Dürr A, Böckler D. Clinical significance of type II endoleaks after thoracic endovascular aortic repair. J Vasc Surg 2013; 58:643-50. [PMID: 23683377 DOI: 10.1016/j.jvs.2013.03.026] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2013] [Revised: 03/13/2013] [Accepted: 03/18/2013] [Indexed: 11/30/2022]
Abstract
BACKGROUND To evaluate the clinical significance of type II endoleaks (ELII) after thoracic endovascular aortic repair (TEVAR). METHODS From January 1997 to June 2012, a total of 344 patients received TEVAR in our institution. ELII was diagnosed in 30 patients (8.7%; 13 males; median age: 65 years, range: 24 to 84 years), representing the study population of this retrospective, single-center analysis. Mean follow-up was 29.5 months (range, 8 months to 9.5 years). RESULTS Primary ELII was observed in all but two cases (28/30; 93.3%). The most common sources of ELII were the left subclavian artery (LSA; 13/30; 43.3%) and intercostal/bronchial vessels (13/30; 43.3%), followed by visceral arteries (4/30; 13.4%). Overall mortality was 33.3% (10/30). ELII-related death (secondary rupture) was observed in 20% (2/10). Reintervention (RI) procedures for ELII were performed in 9 of 30 patients (30.0%); 5 of 9 (55.6%) in cases with ELII via the LSA. Indications for RI were diameter expansion in five and extensive leakage in four cases. Treatment was successful in five patients (55.6%) but failed in four cases (44.4%). In 12 of 21 (57.1%) untreated patients, ELII sealed during follow-up. In conservatively treated patients, an increase in aortic diameter has been only observed in a patient with secondary ELII. CONCLUSIONS The results presented herein suggest that the clinical impact of ELII after TEVAR must not be underestimated. Albeit a transient finding in most cases, ELII is associated with a relevant RI rate, particularly in cases involving the LSA. RI seems indicated in patients with increasing aortic diameter and/or extensive leakage. Careful surveillance of all patients with ELII is recommended.
Collapse
Affiliation(s)
- Moritz S Bischoff
- Department of Vascular and Endovascular Surgery, Ruprecht-Karls University Heidelberg, Heidelberg, Germany.
| | | | | | | | | | | |
Collapse
|
8
|
Gandini R, Pampana E, Stefanini M, Spano S, Martinelli F, Citraro D, Simonetti G. Neck Remodeling Using the Amplatzer Vascular Plug to Facilitate Endovascular Repair of a Contained Abdominal Aortic Rupture. J Endovasc Ther 2013; 20:20-5. [DOI: 10.1583/12-3978.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
9
|
Balloon-assisted coil embolization of the celiac trunk before endovascular aortic repair of thoracoabdominal aortic aneurysm. Jpn J Radiol 2013; 31:215-9. [PMID: 23315017 DOI: 10.1007/s11604-012-0167-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2012] [Accepted: 11/07/2012] [Indexed: 12/13/2022]
Abstract
PURPOSE Celiac trunk coil embolization before thoracic endovascular aneurysm repair (TEVAR) of a thoracoabdominal aortic aneurysm involving the celiac trunk can prevent type II endoleaks. One disadvantage of conventional coil embolization is the risk of coil displacement. We performed coil embolization under balloon occlusion of the celiac trunk to address this issue. MATERIALS AND METHODS Between December 2008 and January 2011, 5 patients (3 men and 2 women, mean age 76 years) were included in this study. For all patients, after confirming the collateral blood flow from the superior mesenteric artery via the pancreaticoduodenal arcades by using the balloon occlusion test, celiac trunk coil embolization proceeded under balloon occlusion of the proximal part of the celiac trunk. RESULTS Balloon-assisted coil embolization of the celiac trunk was completed for all patients without any complications. All coils were deployed as planned in the short segment of the celiac trunk without displacement. Coil migration, ischemic complications, and endoleaks via the celiac trunk did not arise in any of the patients over a follow-up period of 77-637 (mean 258) days. CONCLUSIONS Balloon-assisted coil embolization of the celiac trunk before TEVAR could be a feasible treatment option for suitable patients.
Collapse
|
10
|
Direct insertion of Amplatzer plugs to control lumbar arteries during open repair of type II endoleaks. J Vasc Surg 2012; 55:1775-8. [PMID: 22326577 DOI: 10.1016/j.jvs.2011.12.076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2011] [Revised: 12/27/2011] [Accepted: 12/28/2011] [Indexed: 11/23/2022]
Abstract
Type II endoleak after endovascular repair of an infrarenal aortic aneurysm (EVAR) may be difficult to diagnose and treat in the best of circumstances. Management is more difficult in the patient with significant renal insufficiency. We report an 81-year-old man with stage IV chronic kidney disease and a rapidly expanding, asymmetric aortic aneurysm sac, 31 months after EVAR. A type II lumbar endoleak was diagnosed by duplex ultrasound imaging and managed successfully with open aortic exposure and direct insertion of Amplatzer plugs into two bleeding lumbar arteries due to complex anatomic factors.
Collapse
|