1
|
Development and evaluation of a rapid, specific, and sensitive loop-mediated isothermal amplification assay to detect Tenacibaculum sp. strain pbs-1 associated with black-spot shell disease in Akoya pearl oysters. Arch Microbiol 2022; 205:43. [PMID: 36575332 DOI: 10.1007/s00203-022-03384-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/13/2022] [Accepted: 12/20/2022] [Indexed: 12/28/2022]
Abstract
Black-spot shell disease decreases pearl quality and threatens pearl oyster survival. Establishment of a rapid, specific, and sensitive assay to detect Tenacibaculum sp. strain Pbs-1 associated with black-spot shell disease is of commercial importance. We developed a rapid, specific, and highly sensitive loop-mediated isothermal amplification (LAMP) assay to detect Tenacibaculum sp. Pbs-1 in Akoya pearl oysters Pinctada fucata. A set of five specific primers (two inner, two outer, and a loop) were designed based on the 16S-23S internal spacer region of strain Pbs-1. The optimum reaction temperature was 63 °C, and concentrations of the inner and loop primers were 1.4 and 1.0 µM, respectively. The LAMP product can be detected using agarose gel electrophoresis, and the color change in the reaction tube can be detected visually (by the naked eye) following the addition of malachite green. Our assay proved to be specific for strain Pbs-1, with no cross-reactivity with five other species of Tenacibaculum. The detection limit of the LAMP assay at 35 min is 50 pg, and at 60 min it is 5 fg. We evaluated the LAMP assay using diseased and healthy pearl oysters. The results demonstrate the suitability and simplicity of this test for rapid field diagnosis of strain Pbs-1.
Collapse
|
2
|
Zaczek-Moczydłowska MA, Mohamed-Smith L, Toldrà A, Hooper C, Campàs M, Furones MD, Bean TP, Campbell K. A Single-Tube HNB-Based Loop-Mediated Isothermal Amplification for the Robust Detection of the Ostreid herpesvirus 1. Int J Mol Sci 2020; 21:E6605. [PMID: 32917059 PMCID: PMC7555478 DOI: 10.3390/ijms21186605] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 08/28/2020] [Accepted: 09/04/2020] [Indexed: 01/05/2023] Open
Abstract
The Ostreid herpesvirus 1 species affects shellfish, contributing significantly to high economic losses during production. To counteract the threat related to mortality, there is a need for the development of novel point-of-care testing (POCT) that can be implemented in aquaculture production to prevent disease outbreaks. In this study, a simple, rapid and specific colorimetric loop-mediated isothermal amplification (LAMP) assay has been developed for the detection of Ostreid herpesvirus1 (OsHV-1) and its variants infecting Crassostrea gigas (C. gigas). The LAMP assay has been optimized to use hydroxynaphthol blue (HNB) for visual colorimetric distinction of positive and negative templates. The effect of an additional Tte UvrD helicase enzyme used in the reaction was also evaluated with an improved reaction time of 10 min. Additionally, this study provides a robust workflow for optimization of primers for uncultured viruses using designed target plasmid when DNA availability is limited.
Collapse
Affiliation(s)
- Maja A. Zaczek-Moczydłowska
- Institute for Global Food Security, School of Biological Sciences, Queen’s University Belfast, Belfast BT9 5DL, UK;
| | - Letitia Mohamed-Smith
- Institute for Global Food Security, School of Biological Sciences, Queen’s University Belfast, Belfast BT9 5DL, UK;
| | - Anna Toldrà
- IRTA, 43540 Sant Carles de la Ràpita, Spain; (A.T.); (M.C.); (M.D.F.)
| | - Chantelle Hooper
- Centre for Environment, Fisheries and Aquaculture Science, Weymouth DT4 8UB, UK;
| | - Mònica Campàs
- IRTA, 43540 Sant Carles de la Ràpita, Spain; (A.T.); (M.C.); (M.D.F.)
| | - M. Dolors Furones
- IRTA, 43540 Sant Carles de la Ràpita, Spain; (A.T.); (M.C.); (M.D.F.)
| | - Tim P. Bean
- The Roslin Institute, The Royal (Dick) School of Veterinary Studies, University of Edinburgh, Midlothian EH25 9RG, UK;
| | - Katrina Campbell
- Institute for Global Food Security, School of Biological Sciences, Queen’s University Belfast, Belfast BT9 5DL, UK;
| |
Collapse
|
3
|
Maurelli MP, Bosco A, Foglia Manzillo V, Vitale F, Giaquinto D, Ciuca L, Molinaro G, Cringoli G, Oliva G, Rinaldi L, Gizzarelli M. Clinical, Molecular and Serological Diagnosis of Canine Leishmaniosis: An Integrated Approach. Vet Sci 2020; 7:vetsci7020043. [PMID: 32295198 PMCID: PMC7378766 DOI: 10.3390/vetsci7020043] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 04/10/2020] [Accepted: 04/10/2020] [Indexed: 12/16/2022] Open
Abstract
Canine leishmaniosis (CanL) is caused by protozoans of the genus Leishmania and characterized by a broad spectrum of clinical signs in dogs. Early diagnosis is of great importance in order to perform an appropriate therapy and to prevent progression towards severe disease. The aim of this study was to compare a point-of-care molecular technique, i.e., the loop-mediated isothermal amplification (LAMP), with a real-time polymerase chain reaction (Rt-PCR), and three serological techniques, i.e., immunofluorescence antibody test (IFAT), enzyme-linked immunosorbent assay (ELISA), and a rapid SNAP Leishmania test, to develop an integrated approach for the diagnosis of CanL. Sixty dogs were chosen after physical examination and collection of blood and sera samples, fine-needle aspiration of lymph nodes, and conjunctival swabs were performed. Lymphadenopathy (82.3%), as well as clinicopathological alterations of total proteins (70.6%), were the most frequent signs. Forty-one (68.3%) samples resulted positive at least to one technique. IFAT resulted in the best serological diagnostic method (specificity = 100%, sensitivity = 97.2%), detecting a higher number of positive samples than those revealed by other techniques. Among the samples used for molecular analysis, fine-needle aspiration of lymph nodes was revealed as the best sample source. LAMP showed a substantial agreement (κ = 0.80; p <0.0001) with Rt-PCR; therefore, it could be promising for the rapid diagnosis of CanL. Nevertheless, further studies should be performed to confirm these findings.
Collapse
Affiliation(s)
- Maria Paola Maurelli
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
- Regional Center for Monitoring Parasitic Diseases (CREMOPAR), Campania Region, 84025 Eboli (Sa), Italy
| | - Antonio Bosco
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
- Regional Center for Monitoring Parasitic Diseases (CREMOPAR), Campania Region, 84025 Eboli (Sa), Italy
| | - Valentina Foglia Manzillo
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
- Correspondence:
| | - Fabrizio Vitale
- National Reference Center for Leishmaniosis, Istituto Zooprofilattico Sperimentale della Sicilia, 90129 Palermo, Italy;
| | - Daniela Giaquinto
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
| | - Lavinia Ciuca
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
- Regional Center for Monitoring Parasitic Diseases (CREMOPAR), Campania Region, 84025 Eboli (Sa), Italy
| | - Giuseppe Molinaro
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
| | - Giuseppe Cringoli
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
- Regional Center for Monitoring Parasitic Diseases (CREMOPAR), Campania Region, 84025 Eboli (Sa), Italy
| | - Gaetano Oliva
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
| | - Laura Rinaldi
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
- Regional Center for Monitoring Parasitic Diseases (CREMOPAR), Campania Region, 84025 Eboli (Sa), Italy
| | - Manuela Gizzarelli
- Department of Veterinary Medicine and Animal Production, University of Naples Federico II, 80137 Naples, Italy; (M.P.M.); (A.B.); (D.G.); (L.C.); (G.M.); (G.C.); (G.O.); (L.R.); (M.G.)
| |
Collapse
|
4
|
Zhao VXT, Wong TI, Zheng XT, Tan YN, Zhou X. Colorimetric biosensors for point-of-care virus detections. MATERIALS SCIENCE FOR ENERGY TECHNOLOGIES 2020; 3:237-249. [PMID: 33604529 PMCID: PMC7148662 DOI: 10.1016/j.mset.2019.10.002] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2019] [Revised: 10/13/2019] [Accepted: 10/14/2019] [Indexed: 05/05/2023]
Abstract
Colorimetric biosensors can be used to detect a particular analyte through color changes easily by naked eyes or simple portable optical detectors for quantitative measurement. Thus, it is highly attractive for point-of-care detections of harmful viruses to prevent potential pandemic outbreak, as antiviral medication must be administered in a timely fashion. This review paper summaries existing and emerging techniques that can be employed to detect viruses through colorimetric assay design with detailed discussion of their sensing principles, performances as well as pros and cons, with an aim to provide guideline on the selection of suitable colorimetric biosensors for detecting different species of viruses. Among the colorimetric methods for virus detections, loop-mediated isothermal amplification (LAMP) method is more favourable for its faster detection, high efficiency, cheaper cost, and more reliable with high reproducible assay results. Nanoparticle-based colorimetric biosensors, on the other hand, are most suitable to be fabricated into lateral flow or lab-on-a-chip devices, and can be coupled with LAMP or portable PCR systems for highly sensitive on-site detection of viruses, which is very critical for early diagnosis of virus infections and to prevent outbreak in a swift and controlled manner.
Collapse
Affiliation(s)
- Victoria Xin Ting Zhao
- College of Engineering, Nanyang Technological University, 70 Nanyang Drive, Singapore 637457, Singapore
| | - Ten It Wong
- Institute of Materials Research and Engineering, ASTAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore
| | - Xin Ting Zheng
- Institute of Materials Research and Engineering, ASTAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore
| | - Yen Nee Tan
- Institute of Materials Research and Engineering, ASTAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore
- Faculty of Science, Agriculture & Engineering, Newcastle University, Newcastle Upon Tyne NE1 7RU, United Kingdom
| | - Xiaodong Zhou
- Institute of Materials Research and Engineering, ASTAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore
| |
Collapse
|
5
|
Detection of isothermally amplified ostreid herpesvirus 1 DNA in Pacific oyster (Crassostrea gigas) using a miniaturised electrochemical biosensor. Talanta 2020; 207:120308. [DOI: 10.1016/j.talanta.2019.120308] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 08/30/2019] [Accepted: 08/31/2019] [Indexed: 01/10/2023]
|
6
|
Durand L, La Carbona S, Geffard A, Possenti A, Dubey JP, Lalle M. Comparative evaluation of loop-mediated isothermal amplification (LAMP) vs qPCR for detection of Toxoplasma gondii oocysts DNA in mussels. Exp Parasitol 2019; 208:107809. [PMID: 31785242 DOI: 10.1016/j.exppara.2019.107809] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 11/18/2019] [Accepted: 11/27/2019] [Indexed: 02/06/2023]
Abstract
The apicomplexan parasite Toxoplasma gondii can infect humans and cause toxoplasmosis. T. gondii has been highly prioritized among the foodborne parasites regarding its global impact on public health. Human infection can occur through multiple routes, including the ingestion of raw or undercooked food contaminated with T. gondii oocysts, such as fresh produce and bivalves. As filter-feeders, bivalves can accumulate and concentrate contaminants, including protozoan (oo)cysts. Although detection of T. gondii in different bivalves by molecular techniques (PCR and qPCR) has been achieved, routine application is currently limited by lack of sensitivity or equipment costs. Here, we describe the assessment of a loop-mediated isothermal amplification (LAMP)-based assay to detect T. gondii oocysts in spiked mussels. Detection limit was down to 5 oocysts/g in tissue and 5 oocyst/ml in hemolymph, and, under the experimental conditions tested, LAMP was found to provide a promising alternative to qPCR.
Collapse
Affiliation(s)
- Loïc Durand
- ACTALIA Food Safety Department, 310 Rue Popielujko, 50 000, Saint-Lô, France; EA 7510, EpidémioSurveillance et Circulation des Parasites dans les Environnements, Laboratoire de Parasitologie Mycologie, Université de Reims Champagne Ardenne, Faculté de Médecine, 51 Rue Cognacq Jay, 51096, Reims, France
| | | | - Alain Geffard
- UMR-I 02 SEBIO (Stress Environnementaux et BIOsurveillance des milieux aquatiques), Université de Reims Champagne Ardenne, UFR Sciences Exactes et Naturelles, Campus Moulin de Housse, BP 1039, 51687, Reims cedex 2, France
| | - Alessia Possenti
- Department of Infectious Diseases, European Union Reference Laboratory for Parasites, Istituto Superiore di Sanità, viale Regina Elena 299, 00161, Rome, Italy
| | - Jitender P Dubey
- United States Department of Agriculture, Animal Parasitic Diseases Laboratory, Agricultural Research Service, Beltsville Agricultural Research Center, Building 1001, Beltsville, MD, 20705, USA
| | - Marco Lalle
- Department of Infectious Diseases, European Union Reference Laboratory for Parasites, Istituto Superiore di Sanità, viale Regina Elena 299, 00161, Rome, Italy.
| |
Collapse
|
7
|
Real-time quantitative isothermal detection of Ostreid herpesvirus-1 DNA in Scapharca subcrenata using recombinase polymerase amplification. J Virol Methods 2018; 255:71-75. [PMID: 29428398 DOI: 10.1016/j.jviromet.2018.02.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 02/06/2018] [Accepted: 02/07/2018] [Indexed: 12/21/2022]
Abstract
Ostreid herpesvirus-1 (OsHV-1) is a well-known pathogen associated with high mortality rates in hatchery-reared larvae and juveniles of different bivalve species worldwide. Early, rapid and accurate diagnosis plays a fundamental role in disease prevention and control in aquaculture. Recombinase polymerase amplification (RPA) is a novel isothermal amplification method, which can amplify detectable amount of DNA at 37 °C-39 °C within 20 min. In the present study, two sets of specific primers and probes were designed for the real-time quantitative RPA (qRPA) detection of OsHV-1 DNA. The sensitivity and specificity of detection were evaluated by comparison with quantitative polymerase chain reaction (qPCR). The detection limit for qRPA assays was shown to be 5 copies DNA/reaction for the primer set ORF95, which was lower than the 100 copies required for the qPCR test. The optimal reaction temperature and time were 37 °C for 20 min, making this approach faster than qPCR. This is the first study to apply qPCR and qRPA methods to detect OsHV-1 in Scapharca subcrenata. The percentage of viral load sample detected by the two methods was 22% and the correlation of the two virus quantitative results was 0.8. Therefore, qRPA assays is sensitive, fast, and high-temperature independent relative to qPCR and is suitable for critical clinical diagnostics use and rapid field analysis in resource-limited settings.
Collapse
|
8
|
Lu Y, Yao B, Wang G, Hong N. The detection of ACLSV and ASPV in pear plants by RT-LAMP assays. J Virol Methods 2017; 252:80-85. [PMID: 29180245 DOI: 10.1016/j.jviromet.2017.11.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Revised: 11/20/2017] [Accepted: 11/21/2017] [Indexed: 10/18/2022]
Abstract
A reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of Apple chlorotic leaf spot virus (ACLSV) and Apple stem pitting virus (ASPV), two important viruses frequently occurring in pear trees. A set of four RT-LAMP primers designed based on the highly conserved region of each CP gene of the two viruses showed high specificity and feasibility for ACLSV and ASPV detections. The RT-LAMP assays for ACLSV and ASPV in pear samples were 104 and 103 times more sensitive than that of conventional RT-PCR assays. The RT-LAMP under optimal reaction condition was subsequently utilized in the detection of the two viruses in-vitro cultures of pear and field pear samples. This study provides a rapid and sensitive tool to determine the infection statues of the two viruses in pear certification program.
Collapse
Affiliation(s)
- Yongcan Lu
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, Hubei 430070, China; The Key Laboratory of Plant Pathology of Hubei Province, College of Plant Science and Technology, Huazhong Agricultural University, Wuhan, Hubei 430070, China
| | - Bingyu Yao
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, Hubei 430070, China; The Key Laboratory of Plant Pathology of Hubei Province, College of Plant Science and Technology, Huazhong Agricultural University, Wuhan, Hubei 430070, China
| | - Guoping Wang
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, Hubei 430070, China; The Key Laboratory of Plant Pathology of Hubei Province, College of Plant Science and Technology, Huazhong Agricultural University, Wuhan, Hubei 430070, China; National Indoor Conservation Center of Virus-free Germplasm of Fruit Crops, Huazhong Agricultural University, Wuhan, Hubei 430070, China
| | - Ni Hong
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan, Hubei 430070, China; The Key Laboratory of Plant Pathology of Hubei Province, College of Plant Science and Technology, Huazhong Agricultural University, Wuhan, Hubei 430070, China; National Indoor Conservation Center of Virus-free Germplasm of Fruit Crops, Huazhong Agricultural University, Wuhan, Hubei 430070, China.
| |
Collapse
|
9
|
Diversity of large DNA viruses of invertebrates. J Invertebr Pathol 2017; 147:4-22. [DOI: 10.1016/j.jip.2016.08.001] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2016] [Revised: 08/03/2016] [Accepted: 08/04/2016] [Indexed: 11/17/2022]
|
10
|
Ranjbar R, Erfanmanesh M, Afshar D, Mohammadi M, Ghaderi O, Haghnazari A. Visual Detection of Enterohemorrhagic Escherichia coli O157:H7 Using Loop-Mediated Isothermal Amplification. Electron Physician 2016; 8:2576-85. [PMID: 27504175 PMCID: PMC4965210 DOI: 10.19082/2576] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2015] [Accepted: 01/20/2016] [Indexed: 11/20/2022] Open
Abstract
INTRODUCTION Escherichia coli O157:H7, an important foodborne pathogen, can cause serious renal damage, which can also lead to mortality. Since a rapid and sensitive method is needed to identify this pathogenic agent, we evaluated Loop-Mediated Isothermal Amplification Assay (LAMP) to detect Escherichia coli O157:H7. METHODS We used six primers that specifically identified the rfbE gene. To examine the sensitivity of the method, different dilutions were subjected to the LAMP reaction. Other bacterial strains also were investigated to determine the specificity of the test. The turbidity of the amplified products was assayed by visual detection. The amplified products were detected by addition of SYBR Green II to the reaction tubes. RESULTS Amplification products were observed as a ladder-like pattern on the agarose gel. A white turbidity emerged in the positive tubes. Under UV light, the positive samples were green, whereas the negative samples were orange. The detection limit of the LAMP was 78 pg/tube, and this indicated that it was 100 times more sensitive than PCR for the detection of EHEC. No LAMP products were detected when template DNA of non-EHEC strains were used, suggesting high specificity of the LAMP assay. CONCLUSION The results indicated that the LAMP assay is a valuable diagnostic assay to identify EHEC O157:H7. In addition, the simplicity, sensitivity, specificity, and rapidity of this assay make it a useful method to diagnose pathogens in primary labs without any need for expensive equipment or specialized techniques.
Collapse
Affiliation(s)
- Reza Ranjbar
- Ph.D. of Medical Bacteriology, Professor, Molecular Biology Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Maryam Erfanmanesh
- M.Sc. of Biotechnology, Department of Agriculture and Plant Breeding, Faculty of Agriculture, Zanjan University, Zanjan, Iran
| | - Davoud Afshar
- Ph.D. of Medical Bacteriology, Department of Pathobiology, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohsen Mohammadi
- Ph.D. of Pharmaceutical Biotechnology, Assistant Professor, Department of Pharmaceutical Biotechnology, Faculty of Pharmacy, Lorestan University of Medical Sciences, Khorramabad, Iran
| | - Omar Ghaderi
- Ph.D. Candidate of Pharmaceutical Biotechnology, Department of Pharmaceutical Biotechnology, Tehran University of Medical Sciences, Tehran, Iran
| | - Ali Haghnazari
- Department of Agriculture and Plant Breeding, Faculty of Agriculture, Zanjan University, Zanjan, Iran
| |
Collapse
|
11
|
A loop-mediated isothermal amplification assay for rapid detection of cyprinid herpesvirus 2 in gibel carp (Carassius auratus gibelio). ScientificWorldJournal 2014; 2014:716413. [PMID: 24574914 PMCID: PMC3916102 DOI: 10.1155/2014/716413] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2013] [Accepted: 10/28/2013] [Indexed: 11/30/2022] Open
Abstract
A rapid and sensitive loop-mediated isothermal amplification (LAMP) assay for Cyprinid herpesvirus 2 (CyHV-2) detection in gibel carp was developed. Following cloning and sequencing of the putative DNA helicase gene of CyHV-2 isolate from China, a set of four specific primers was designed based on the sequence. The MgCl2 concentration and the reaction temperature were optimized to 6 mM, 64°C, respectively. LAMP products were detected by visual inspection of a color change due to addition of SYBR Green I stain. The specificity and sensitivity of the LAMP assay were determined. No cross-reaction was observed with other fish DNA viruses including eel herpesvirus, koi herpesvirus, and Chinese giant salamander iridovirus. The LAMP assay was found to be equally sensitive as nested PCR. A comparative evaluation of 10 fish samples using LAMP and nested PCR assays showed an overall correlation in positive and negative results for CyHV-2. These results indicate that the LAMP assay is simple, sensitive, and specific and has a great potential use for CyHV-2 detection in the laboratory and field.
Collapse
|
12
|
Chen MH, Kuo ST, Renault T, Chang PH. The development of a loop-mediated isothermal amplification assay for rapid and sensitive detection of abalone herpesvirus DNA. J Virol Methods 2013; 196:199-203. [PMID: 24291740 DOI: 10.1016/j.jviromet.2013.11.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2013] [Revised: 11/16/2013] [Accepted: 11/20/2013] [Indexed: 11/25/2022]
Abstract
A loop-mediated isothermal amplification (LAMP) assay was developed for the detection of abalone herpesvirus DNA. Two pairs of primers were designed, based on the sequence of the DNA polymerase gene of abalone herpesvirus. The reaction temperature and time were optimized to 63°C and 60min, respectively. LAMP amplicons were analyzed by 2% agarose gel electrophoresis or by visual inspection of a colour change emitted by fluorescent dye. The method developed was specific for the detection of abalone herpesvirus, without cross-reactions with other tested herpesviruses including ostreid herpesvirus 1 (OsHV-1), European eel herpesvirus, koi herpesvirus (KHV) and an avian herpesvirus. The LAMP assay was 100 folds more sensitive than a conventional PCR and 10 folds less sensitive than a SYBR Green PCR. These results indicate that the developed LAMP assay is a simple, rapid, sensitive, specific and reliable technique for the detection of abalone herpesvirus.
Collapse
Affiliation(s)
- M H Chen
- Institute of Veterinary Medicine, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan; Tzu Chi College of Technology, Hualien, Taiwan
| | - S T Kuo
- National Institute for Animal Health, Tansui, Taiwan
| | - T Renault
- Ifremer, Unité Santé Génétique et Microbiologie des Mollusques, Laboratoire de Génétique et Pathologie des Mollusques Marins, 17390 La Tremblade, France
| | - P H Chang
- Institute of Veterinary Medicine, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan.
| |
Collapse
|
13
|
Almasi MA, Erfan Manesh M, Jafary H, Dehabadi SMH. Visual detection of Potato Leafroll virus by loop-mediated isothermal amplification of DNA with the GeneFinder™ dye. J Virol Methods 2013; 192:51-4. [PMID: 23680094 DOI: 10.1016/j.jviromet.2013.04.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2012] [Revised: 04/10/2013] [Accepted: 04/15/2013] [Indexed: 11/25/2022]
Abstract
The most common virus affecting potatoes in the field worldwide is Potato Leafroll virus (PLRV), belonging to the family Luteoviridae, genius Plerovirus. There are several molecular methods to detect PLRV including polymerase chain reaction (PCR), Multiplex AmpliDet RNA and double antibody sandwich ELISA (DAS-ELISA). But these techniques take a long time for 3h to two days, requiring sophisticated tools. The aim of this study was to reduce the time required to detect PLRV, using a newly designed loop-mediated isothermal amplification (LAMP) technique requiring only an ordinary water bath or thermoblock. PLRV RNA was extracted from overall 80 infected naturally potato leaves. A set of six novel primers for the LAMP reaction was designed according to the highly conserved sequence of the viral coat protein (CP) gene. LAMP was carried out under isothermal conditions, applying the Bst DNA polymerase enzyme; the LAMP products were detected visually using the GeneFinder™ florescence dye. A positive result using the GeneFinder™ dye was a color change from the original orange to green. Results confirmed LAMP with GeneFinder™ provides a rapid and safe assay for detection of PLRV. Since with other molecular methods, equipping laboratories with a thermocycler or expensive detector systems is unavoidable, this assay was found to be a simple, cost-effective molecular method that has the potential to replace other diagnostic methods in primary laboratories without the need for expensive equipment or specialized techniques. It can also be considered as a reliable alternative viral detection system in further investigations.
Collapse
Affiliation(s)
- Mohammad Amin Almasi
- Department of Agriculture and Plant Breeding, Faculty of Agriculture, Zanjan University, Zanjan, Iran
| | | | | | | |
Collapse
|