1
|
Chen Q, Zhang LJ, Song TY, Ge JQ. Development of a loop-mediated isothermal amplification (LAMP) assay for rapid and visual detection of Anguillid herpesvirus 1. J Virol Methods 2024; 330:115014. [PMID: 39214419 DOI: 10.1016/j.jviromet.2024.115014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Revised: 08/19/2024] [Accepted: 08/26/2024] [Indexed: 09/04/2024]
Abstract
China has the largest aquaculture eel production in the world. High-density cultivation pattern often results in an outbreak of epidemic diseases. Since the 1990s, eel "mucus sloughing and hemorrhagic septicemia disease" was often broke out in China, and brought huge economic losses to eel breeders. Anguillid herpesvirus 1 (AngHV) was detected and isolated from the diseased eel, and proved to be the pathogen of the disease. In this study, a loop-mediated isothermal amplification (LAMP) assay was developed for rapid, sensitive, and specific detection of AngHV. A set of six primers targeting the ORF51 gene of AngHV was designed, which could effectively detect purified AngHV virions, AngHV-infected cells, or eel tissue samples. The suitable reaction temperature is 63℃, and the reaction time is 40 min. There was no cross-reaction with eel and other fish viruses, including Infectious pancreatic necrosis virus (IPNV), Marine birnavirus (MABV), Rana grylio virus (RGV), Cyprinid herpesvirus 3 (CyHV-3), and Eel iridovirus (EIV). The lower detection limit of the AngHV LAMP assay is 10 copies of AngHV genome DNA, which is at least 100 times more sensitive than conventional PCR in detecting AngHV. The assay could effectively detect AngHV from collected samples with typical clinical symptoms of AngHV infection. It suggested that the LAMP assay could be used in specific detection of AngHV and has great potential for early diagnosis of AngHV infection in the farm.
Collapse
Affiliation(s)
- Qiang Chen
- Institute of Biotechnology, Fujian Academy of Agricultural Sciences, Fuzhou 350003, China
| | - Li-Juan Zhang
- Institute of Biotechnology, Fujian Academy of Agricultural Sciences, Fuzhou 350003, China
| | - Tie-Ying Song
- Institute of Biotechnology, Fujian Academy of Agricultural Sciences, Fuzhou 350003, China
| | - Jun-Qing Ge
- Institute of Biotechnology, Fujian Academy of Agricultural Sciences, Fuzhou 350003, China.
| |
Collapse
|
2
|
Cano I, Wood G, Stone D, Noyer M, Canier L, Arzul I. Loop-Mediated Isothermal Amplification for the Fast Detection of Bonamia ostreae and Bonamia exitiosa in Flat Oysters. Pathogens 2024; 13:132. [PMID: 38392870 PMCID: PMC10893247 DOI: 10.3390/pathogens13020132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/26/2024] [Accepted: 01/27/2024] [Indexed: 02/25/2024] Open
Abstract
The haplosporidian parasites Bonamia ostreae (BO) and B. exitiosa (BE) are serious oyster pathogens. Two independent laboratories evaluated fluorescence real-time loop-mediated isothermal amplification (LAMP) assays for rapidly detecting these parasites. Specific LAMP assays were designed on the BO actin-1 and BE actin genes. A further generic assay was conceived on a conserved region of the 18S gene to detect both Bonamia species. The optimal reaction temperature varied from 65 to 67 °C depending on the test and instrument. Melting temperatures were 89.8-90.2 °C, 87.0-87.6 °C, and 86.2-86.6 °C for each of the BO, BE, and generic assays. The analytical sensitivity of these assays was 50 copies/µL in a 30 min run. The BO and BE test sensitivity was ~1 log lower than a real-time PCR, while the generic test sensitivity was similar to the real-time PCR. Both the BO and BE assays were shown to be specific; however, the generic assay potentially cross-reacts with Haplosporidium costale. The performance of the LAMP assays evaluated on samples of known status detected positives within 7-20 min with a test accuracy of 100% for the BO and generic tests and a 95.8% accuracy for BE. The ease of use, rapidity and affordability of these tests allow for field deployment.
Collapse
Affiliation(s)
- Irene Cano
- The International Centre of Excellence for Aquatic Animal Health, Cefas Weymouth Laboratory, Weymouth, Dorset DT4 8UB, UK (D.S.)
| | - Gareth Wood
- The International Centre of Excellence for Aquatic Animal Health, Cefas Weymouth Laboratory, Weymouth, Dorset DT4 8UB, UK (D.S.)
| | - David Stone
- The International Centre of Excellence for Aquatic Animal Health, Cefas Weymouth Laboratory, Weymouth, Dorset DT4 8UB, UK (D.S.)
| | - Mathilde Noyer
- The Institut Français de Recherche pour l’Exploitation de la Mer Ifremer, RBE-SG2M-ASIM, Station de La Tremblade, Avenue de Mus de Loup, La Tremblade, 17390 Brest, France; (M.N.); (L.C.); (I.A.)
| | - Lydie Canier
- The Institut Français de Recherche pour l’Exploitation de la Mer Ifremer, RBE-SG2M-ASIM, Station de La Tremblade, Avenue de Mus de Loup, La Tremblade, 17390 Brest, France; (M.N.); (L.C.); (I.A.)
| | - Isabelle Arzul
- The Institut Français de Recherche pour l’Exploitation de la Mer Ifremer, RBE-SG2M-ASIM, Station de La Tremblade, Avenue de Mus de Loup, La Tremblade, 17390 Brest, France; (M.N.); (L.C.); (I.A.)
| |
Collapse
|
3
|
Park JW. Principles and Applications of Loop-Mediated Isothermal Amplification to Point-of-Care Tests. BIOSENSORS 2022; 12:bios12100857. [PMID: 36290994 PMCID: PMC9599884 DOI: 10.3390/bios12100857] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 09/30/2022] [Accepted: 10/08/2022] [Indexed: 05/03/2023]
Abstract
For the identification of nucleic acids, which are important biomarkers of pathogen-mediated diseases and viruses, the gold standard for NA-based diagnostic applications is polymerase chain reaction (PCR). However, the requirements of PCR limit its application as a rapid point-of-care diagnostic technique. To address the challenges associated with regular PCR, many isothermal amplification methods have been developed to accurately detect NAs. Isothermal amplification methods enable NA amplification without changes in temperature with simple devices, as well as faster amplification times compared with regular PCR. Of the isothermal amplifications, loop-mediated isothermal amplification (LAMP) is the most studied because it amplifies NAs rapidly and specifically. This review describes the principles of LAMP, the methods used to monitor the process of LAMP, and examples of biosensors that detect the amplicons of LAMP. In addition, current trends in the application of LAMP to smartphones and self-diagnosis systems for point-of-care tests are also discussed.
Collapse
Affiliation(s)
- Jee-Woong Park
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation (K-MEDI Hub), Daegu 41061, Korea
| |
Collapse
|
4
|
Wang H, Wang S, Wang H, Liang Y, Jia Y, Li Z. Light Scattering Technology-Combined Ligation-Dependent Loop-Mediated Isothermal Amplification (LL-LAMP) for Sensitive Detection of RNA. ACS OMEGA 2022; 7:19957-19963. [PMID: 35721910 PMCID: PMC9202044 DOI: 10.1021/acsomega.2c01759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 05/24/2022] [Indexed: 06/15/2023]
Abstract
Loop-mediated isothermal amplification (LAMP) has been widely used in nucleic acid assay because of its high specificity, sensitivity, and isothermal property. However, the complexity of amplification product detection is still a major challenge for its wide applications. Herein, we developed a light scattering technology-assisted, low-cost, and simple detection manner of LAMP products without expensive reagents and complicated instruments. Only needing to add a kind of strong acid to the amplification products, the amplification products can aggregate into large particles in a strongly acidic medium, and large particles can produce strong light scattering, which shows a good proportional relationship with the number of amplification products in a wide range. The proposed method shows excellent sensitivity and high specificity that can quantify RNA as low as 100 aM with a single-base resolution.
Collapse
|
5
|
Abalone Viral Ganglioneuritis. Pathogens 2020; 9:pathogens9090720. [PMID: 32882932 PMCID: PMC7558354 DOI: 10.3390/pathogens9090720] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 08/23/2020] [Accepted: 08/29/2020] [Indexed: 11/17/2022] Open
Abstract
Abalone viral ganglioneuritis (AVG), caused by Haliotid herpesvirus-1 (HaHV-1; previously called abalone herpesvirus), is a disease that has been responsible for extensive mortalities in wild and farmed abalone and has caused significant economic losses in Asia and Australia since outbreaks occurred in the early 2000s. Researchers from Taiwan, China, and Australia have conducted numerous studies encompassing HaHV-1 genome sequencing, development of molecular diagnostic tests, and evaluation of the susceptibility of various abalone species to AVG as well as studies of gene expression in abalone upon virus infection. This review presents a timeline of the most significant research findings on AVG and HaHV-1 as well as potential future research avenues to further understand this disease in order to develop better management strategies.
Collapse
|
6
|
Rapid visual detection of Vibrio parahaemolyticus in seafood samples by loop-mediated isothermal amplification with hydroxynaphthol blue dye. World J Microbiol Biotechnol 2020; 36:76. [PMID: 32390085 DOI: 10.1007/s11274-020-02851-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 05/04/2020] [Indexed: 10/24/2022]
Abstract
The detection and monitoring of Vibrio parahaemolyticus pathogen in aquatic foods have become essential for preventing outbreaks. In this study, loop-mediated isothermal amplification (LAMP) assay with the azo dye, hydroxynaphthol blue (HNB) was developed targeting species-specific tlh gene. The assay was carried out on 62 seafood samples that included clam and shrimp and compared with conventional LAMP assay performed with the commonly used fluorescent dye, conventional PCR, and real-time PCR (RT-PCR). Of 62 samples studied for tlh gene, 32 (51.61%) gave positive by HNB-LAMP, which comprised 22 (70.96%) clam samples and 10 (32.25%) shrimp samples. The HNB-LAMP assay was found to be highly sensitive, specific, and superior to conventional PCR (p > 0.05). RT-PCR presented higher sensitivity than HNB-LAMP; however, it has the limitation of being cost-intensive and requiring technical expertise to perform. HNB-LAMP is affordable, rapid, simple, and easy to perform, allowing naked eye visualization.
Collapse
|
7
|
Zhang M, Li Y, Jing H, Wang N, Wu S, Wang Q, Lin X. Development of polyclonal-antibody-coated immunomagnetic beads for separation and detection of koi herpesvirus in large-volume samples. Arch Virol 2020; 165:973-976. [PMID: 32060793 DOI: 10.1007/s00705-020-04557-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 01/20/2020] [Indexed: 02/07/2023]
Abstract
To separate and concentrate koi herpesvirus (KHV) from large-volume samples, a separation method based on immunomagnetic beads (IMBs) coated with polyclonal antibody directed against KHV was developed. After treatment with IMBs, viral DNA was extracted from samples and used as a template for quantitative PCR (qPCR). The results showed that the concentration of the template DNA extracted from the virus that had been separated using IMBs was 9.65-fold higher than that from virus not treated with IMBs. The detection limit of the IMBs/qPCR method was found to be at least 10 times lower than that of qPCR alone.
Collapse
Affiliation(s)
- Min Zhang
- The Institute of Animal Quarantine, Chinese Academy of Inspection and Quarantine, No. 11 Building, Ronghua South Road, Daxing District, Beijing, 100176, China
| | - Yingying Li
- Key Laboratory of Fishery Drug Development of the Ministry of Agriculture and Rural Affairs, Key Laboratory of Aquatic Animal Immune Technology of Guangdong Province, Pearl River Fisheries Research Institute, Chinese Academy of Fishery Sciences, Guangzhou, Guangdong, 510380, China
| | - Hongli Jing
- The Institute of Animal Quarantine, Chinese Academy of Inspection and Quarantine, No. 11 Building, Ronghua South Road, Daxing District, Beijing, 100176, China
| | - Na Wang
- The Institute of Animal Quarantine, Chinese Academy of Inspection and Quarantine, No. 11 Building, Ronghua South Road, Daxing District, Beijing, 100176, China
| | - Shaoqiang Wu
- The Institute of Animal Quarantine, Chinese Academy of Inspection and Quarantine, No. 11 Building, Ronghua South Road, Daxing District, Beijing, 100176, China
| | - Qing Wang
- Key Laboratory of Fishery Drug Development of the Ministry of Agriculture and Rural Affairs, Key Laboratory of Aquatic Animal Immune Technology of Guangdong Province, Pearl River Fisheries Research Institute, Chinese Academy of Fishery Sciences, Guangzhou, Guangdong, 510380, China.
| | - Xiangmei Lin
- The Institute of Animal Quarantine, Chinese Academy of Inspection and Quarantine, No. 11 Building, Ronghua South Road, Daxing District, Beijing, 100176, China.
| |
Collapse
|
8
|
Zhao VXT, Wong TI, Zheng XT, Tan YN, Zhou X. Colorimetric biosensors for point-of-care virus detections. MATERIALS SCIENCE FOR ENERGY TECHNOLOGIES 2019; 3:237-249. [PMID: 33604529 PMCID: PMC7148662 DOI: 10.1016/j.mset.2019.10.002] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2019] [Revised: 10/13/2019] [Accepted: 10/14/2019] [Indexed: 05/05/2023]
Abstract
Colorimetric biosensors can be used to detect a particular analyte through color changes easily by naked eyes or simple portable optical detectors for quantitative measurement. Thus, it is highly attractive for point-of-care detections of harmful viruses to prevent potential pandemic outbreak, as antiviral medication must be administered in a timely fashion. This review paper summaries existing and emerging techniques that can be employed to detect viruses through colorimetric assay design with detailed discussion of their sensing principles, performances as well as pros and cons, with an aim to provide guideline on the selection of suitable colorimetric biosensors for detecting different species of viruses. Among the colorimetric methods for virus detections, loop-mediated isothermal amplification (LAMP) method is more favourable for its faster detection, high efficiency, cheaper cost, and more reliable with high reproducible assay results. Nanoparticle-based colorimetric biosensors, on the other hand, are most suitable to be fabricated into lateral flow or lab-on-a-chip devices, and can be coupled with LAMP or portable PCR systems for highly sensitive on-site detection of viruses, which is very critical for early diagnosis of virus infections and to prevent outbreak in a swift and controlled manner.
Collapse
Affiliation(s)
- Victoria Xin Ting Zhao
- College of Engineering, Nanyang Technological University, 70 Nanyang Drive, Singapore 637457, Singapore
| | - Ten It Wong
- Institute of Materials Research and Engineering, ASTAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore
| | - Xin Ting Zheng
- Institute of Materials Research and Engineering, ASTAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore
| | - Yen Nee Tan
- Institute of Materials Research and Engineering, ASTAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore
- Faculty of Science, Agriculture & Engineering, Newcastle University, Newcastle Upon Tyne NE1 7RU, United Kingdom
| | - Xiaodong Zhou
- Institute of Materials Research and Engineering, ASTAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-03, Innovis, Singapore 138634, Singapore
| |
Collapse
|
9
|
Anupama KP, Chakraborty A, Karunasagar I, Karunasagar I, Maiti B. Loop-mediated isothermal amplification assay as a point-of-care diagnostic tool for Vibrio parahaemolyticus: recent developments and improvements. Expert Rev Mol Diagn 2019; 19:229-239. [PMID: 30657706 DOI: 10.1080/14737159.2019.1571913] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
INTRODUCTION A number of DNA-based diagnostic tools have been developed for the detection of Vibrio parahaemolyticus in seafood. However, the loop-mediated isothermal amplification (LAMP) has distinct advantages with regards to its simplicity, speed and the ease of performing without any need for sophisticated equipment. Over the last decade, LAMP has emerged as a potential tool for the detection of V. parahaemolyticus. Area covered: The literature search was restricted to LAMP assay and its variants for the detection of V. parahaemolyticus. The focus in this review is to enlist the various techniques that have been developed using the principle of the LAMP towards improved simplicity, sensitivity and specificity of the assay. Expert commentary: LAMP assay and its variants are significantly faster and require minimum accessories compared to other DNA based molecular techniques such as PCR and their types. Despite the availability of several versions, LAMP-based diagnostics is not the first choice for the detection of V. parahaemolyticus in the seafood sector. Our recommendation would be to explore the possibilities of developing cost-effective LAMP kits and implementing these kits as point-of-care diagnostic tools for rapid and sensitive detection of pathogenic V. parahaemolyticus.
Collapse
Affiliation(s)
- Karanth Padyana Anupama
- a Division of Infectious Diseases , Nitte University Centre for Science Education and Research , Mangaluru , India
| | - Anirban Chakraborty
- b Division of Molecular Genetics and Cancer , Nitte University Centre for Science Education and Research , Mangaluru , India
| | - Iddya Karunasagar
- c NITTE (Deemed to be University), University Enclave , Mangaluru, Medical Sciences Complex , India
| | - Indrani Karunasagar
- a Division of Infectious Diseases , Nitte University Centre for Science Education and Research , Mangaluru , India.,c NITTE (Deemed to be University), University Enclave , Mangaluru, Medical Sciences Complex , India
| | - Biswajit Maiti
- a Division of Infectious Diseases , Nitte University Centre for Science Education and Research , Mangaluru , India
| |
Collapse
|
10
|
Diversity of large DNA viruses of invertebrates. J Invertebr Pathol 2017; 147:4-22. [DOI: 10.1016/j.jip.2016.08.001] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2016] [Revised: 08/03/2016] [Accepted: 08/04/2016] [Indexed: 11/17/2022]
|
11
|
Zhang X, Lowe SB, Gooding JJ. Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP). Biosens Bioelectron 2014; 61:491-9. [DOI: 10.1016/j.bios.2014.05.039] [Citation(s) in RCA: 194] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Revised: 05/14/2014] [Accepted: 05/15/2014] [Indexed: 01/20/2023]
|
12
|
Loop-mediated isothermal amplification (LAMP) assays for detection and identification of aquaculture pathogens: current state and perspectives. Appl Microbiol Biotechnol 2014; 98:2881-95. [DOI: 10.1007/s00253-014-5531-z] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2013] [Revised: 01/08/2014] [Accepted: 01/09/2014] [Indexed: 11/26/2022]
|